{"product_id":"mitsubishi-electric-fx5u-64mt-ds-melsec-iq-f-series-cpu-module","title":"Mitsubishi Electric FX5U-64MT\/DS MELSEC iQ-F Series CPU Module","description":"\u003ch1\u003eMitsubishi Electric FX5U-64MT\/DS MELSEC iQ-F Series CPU Module\u003c\/h1\u003e\n\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eDesigned for high-performance industrial automation, the \u003cstrong\u003eFX5U-64MT\/DS\u003c\/strong\u003e serves as a central processing unit within the Mitsubishi Electric MELSEC iQ-F Series. This controller integrates advanced processing capabilities, built-in Ethernet, analog I\/O, and high-speed positioning controls into a compact form factor. It manages up to 64 local I\/O points (32 inputs and 32 outputs) and supports expansion options to scale with complex machinery requirements. The module features high-speed execution times, making it suitable for demanding applications requiring precise timing and synchronization.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eHigh-speed program execution of 0.034 microseconds per basic instruction.\u003c\/li\u003e\n  \u003cli\u003eBuilt-in Ethernet port for network communication, programming, and monitoring.\u003c\/li\u003e\n  \u003cli\u003eBuilt-in RS-485 port supporting Modbus RTU and proprietary protocols.\u003c\/li\u003e\n  \u003cli\u003eIntegrated SD card slot for data logging, program backups, and system updates.\u003c\/li\u003e\n  \u003cli\u003eBuilt-in analog inputs and outputs for direct sensor and actuator interfacing.\u003c\/li\u003e\n  \u003cli\u003eHigh-speed counter inputs and pulse outputs for multi-axis positioning control.\u003c\/li\u003e\n  \u003cli\u003eScrew terminal block connections for secure and reliable field wiring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003ePackaging and labeling machinery\u003c\/li\u003e\n  \u003cli\u003eMaterial handling and conveyor systems\u003c\/li\u003e\n  \u003cli\u003eWater and wastewater treatment facilities\u003c\/li\u003e\n  \u003cli\u003eFood and beverage processing lines\u003c\/li\u003e\n  \u003cli\u003eHVAC and environmental control systems\u003c\/li\u003e\n  \u003cli\u003eAssembly and test bench automation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eMitsubishi Electric\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePart Number\/Model\u003c\/td\u003e\n      \u003ctd\u003eFX5U-64MT\/DS\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSeries\u003c\/td\u003e\n      \u003ctd\u003eMELSEC iQ-F Series\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModule Type\u003c\/td\u003e\n      \u003ctd\u003eCPU Module\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTotal I\/O Points\u003c\/td\u003e\n      \u003ctd\u003e64 points\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNumber of Inputs\u003c\/td\u003e\n      \u003ctd\u003e32 points\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNumber of Outputs\u003c\/td\u003e\n      \u003ctd\u003e32 points\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInput Type\u003c\/td\u003e\n      \u003ctd\u003e24 V DC (Sink\/Source)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOutput Type\u003c\/td\u003e\n      \u003ctd\u003eTransistor (Sink)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Supply Voltage\u003c\/td\u003e\n      \u003ctd\u003e24 V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e5 V DC Power Supply Capacity\u003c\/td\u003e\n      \u003ctd\u003e1100 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e24 V DC Power Supply Capacity\u003c\/td\u003e\n      \u003ctd\u003e740 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConnection Type\u003c\/td\u003e\n      \u003ctd\u003eScrew terminal block\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd\u003e0 to 55 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStorage Temperature\u003c\/td\u003e\n      \u003ctd\u003e-25 to 75 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eShipping Weight\u003c\/td\u003e\n      \u003ctd\u003e2 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eInterface Port\u003c\/th\u003e\n      \u003cth\u003eConnection Type\u003c\/th\u003e\n      \u003cth\u003eFunctionality\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEthernet\u003c\/td\u003e\n      \u003ctd\u003eRJ45 Connector\u003c\/td\u003e\n      \u003ctd\u003eProgramming, MC Protocol, Modbus\/TCP, and CC-Link IE Field Basic\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRS-485\u003c\/td\u003e\n      \u003ctd\u003eTerminal Block\u003c\/td\u003e\n      \u003ctd\u003eSerial communication, Modbus RTU, and inverter communication\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSD Card Slot\u003c\/td\u003e\n      \u003ctd\u003eStandard SD Slot\u003c\/td\u003e\n      \u003ctd\u003eData logging, parameter storage, and firmware updates\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eI\/O Terminals\u003c\/td\u003e\n      \u003ctd\u003eScrew Terminals\u003c\/td\u003e\n      \u003ctd\u003eDirect connection for digital inputs, outputs, and analog signals\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Mount securely on a 35mm DIN rail or use direct screw mounting in a clean, dry control cabinet.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Ensure a dedicated Class D grounding (grounding resistance of 100 ohms or less) using a minimum 2 mm² wire. Do not share grounding wires with high-power equipment.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eClearance:\u003c\/strong\u003e Maintain a minimum clearance of 50 mm above and below the module to allow for natural convection cooling and routing of cables.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Route low-voltage DC signal lines and communication cables separately from high-voltage AC power lines to prevent electromagnetic interference.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCE\u003c\/li\u003e\n  \u003cli\u003eUL \/ cUL\u003c\/li\u003e\n  \u003cli\u003eKC (Korean Certification)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":53102230372715,"sku":"FX5U-64MT\/DS","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/fx5u-64mtds-ljdus3jp05g.png?v=1776137565","url":"https:\/\/www.plcprotech.com\/id\/products\/mitsubishi-electric-fx5u-64mt-ds-melsec-iq-f-series-cpu-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}