{"product_id":"mitsubishi-electric-gt2710-vtbd-got2000-advanced-hmi-touch-screen","title":"Mitsubishi Electric GT2710-VTBD GOT2000 Advanced HMI Touch Screen","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eDesigned for complex automation tasks, the \u003cstrong\u003eGT2710-VTBD\u003c\/strong\u003e is a high-performance Human-Machine Interface (HMI) from the Mitsubishi Electric GOT2000 series. This advanced model features a 10.4-inch VGA TFT color display and supports multi-touch gesture operations, allowing operators to easily pinch, zoom, and swipe through detailed graphic screens. Engineered to withstand demanding factory floor environments, this unit provides seamless visualization and control system interfaces for PLC, inverter, and motion control configurations.\u003c\/p\u003e\n\n\u003cp\u003eThe unit features a black frame bezel and operates on a 24VDC power supply. By utilizing robust internal cooling and high impact resistance components, the \u003cstrong\u003eGT2710-VTBD\u003c\/strong\u003e ensures reliable, long-term operation inside industrial control enclosures. It serves as a central control and monitoring station in both localized machines and distributed factory networks.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e10.4-inch TFT color display with VGA resolution (640 x 480 pixels) for clear, detailed industrial graphics.\u003c\/li\u003e\n  \u003cli\u003eIntuitive multi-touch and gesture capability for enhanced screen navigation and parameter adjustments.\u003c\/li\u003e\n  \u003cli\u003eRobust noise immunity and 350VAC withstand voltage to handle electrical fluctuations on industrial power lines.\u003c\/li\u003e\n  \u003cli\u003eFlexible mounting options supporting both horizontal and vertical installation orientations.\u003c\/li\u003e\n  \u003cli\u003eWide operating temperature envelope up to 55 degC for hot-running control panel environments.\u003c\/li\u003e\n  \u003cli\u003eSelf-cooling design that eliminates the need for external fan units, reducing dust ingress and maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eAutomotive assembly lines and conveyor control systems.\u003c\/li\u003e\n  \u003cli\u003eWater and wastewater processing equipment panels.\u003c\/li\u003e\n  \u003cli\u003eOil, gas, and chemical processing visualization systems.\u003c\/li\u003e\n  \u003cli\u003ePower generation and distribution control panels.\u003c\/li\u003e\n  \u003cli\u003ePackaging, textile, and material handling machinery.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth colspan=\"2\"\u003eSystem and Electrical Parameters\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMitsubishi Electric\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel \/ Article Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eGT2710-VTBD (270561)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eGOT2000 Series\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDisplay Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eTFT Color LCD\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eScreen Size\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e10.4 inches\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eVGA (640 x 480 pixels)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFrame Color\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBlack\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Power Supply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e24VDC (+25%, -20%)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMaximum Power Consumption\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e42W or less\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Consumption (Standalone)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e15W (8W or less with backlight turned off)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInrush Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e5A or less (duration 20ms at ambient 25 degC, maximum load)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePermissible Instantaneous Failure Time\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eWithin 10ms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNoise Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e500Vp-p noise voltage, 1us pulse width via noise simulator (25 to 60Hz frequency)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWithstand Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e350VAC for 1 minute between power supply terminal and ground\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e10 Mohm or higher (measured at 500VDC between power supply terminal and ground)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eApplicable Wire Size\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.75 to 2 mm2\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTerminal Block Screw Size\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eM3 screw clamp terminals\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTightening Torque\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.5 to 0.8 N.m\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e30.3 cm x 21.8 cm x 5.2 cm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight (Excluding brackets)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2.1 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth colspan=\"2\"\u003eEnvironmental Parameters\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Ambient Temperature (Horizontal Installation)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to 55 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Ambient Temperature (Vertical Installation)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to 50 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-20 to 60 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating\/Storage Humidity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e10 to 90% RH (non-condensing)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eImpact Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCompliant with JIS B 3502 and IEC 61131-2 (147 m\/s2 \/ 15G, 3 times in X, Y, and Z axes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Altitude\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eUp to 2000 meters (6562 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Atmosphere\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNo greasy fumes, corrosive gas, flammable gas, excessive conductive dust, or direct sunlight\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInstallation Location\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eInside closed industrial control panel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOvervoltage Category\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCategory II or less\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2 or less\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCooling Method\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSelf-cooling\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eTerminal Name\u003c\/th\u003e\n      \u003cth\u003eFunction and Cable Specification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Terminals (24VDC)\u003c\/td\u003e\n      \u003ctd\u003eAccepts 0.75 to 2 mm2 conductors. Requires M3 ring or spade terminals (RAV1.25-3, V2-S3.3, V2-N3A, FV2-N3A).\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eGround Terminal (FG)\u003c\/td\u003e\n      \u003ctd\u003eDedicated frame ground terminal. Use recommended tightening torque of 0.5 to 0.8 N.m.\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnclosure Mounting:\u003c\/strong\u003e Always install the HMI inside a dust-tight, IP-rated industrial control cabinet. Ensure the mounting clamps are uniformly tightened to prevent screen distortion or water ingress.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOrientation and Thermal Derating:\u003c\/strong\u003e Note that vertical mounting limits the maximum allowable ambient operating temperature to 50 degC, while horizontal mounting permits up to 55 degC.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWiring Best Practices:\u003c\/strong\u003e Use shielded power cabling with a minimum cross-section of 0.75 mm2. Separate all low-voltage signal lines from high-voltage AC power lines to avoid electromagnetic interference.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Connect the FG terminal directly to a low-impedance facility earth ground with the shortest possible conductor.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":53102131315051,"sku":"GT2710-VTBD","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/gt2710-vtbd-jem2ekhsvsd.png?v=1776137632","url":"https:\/\/www.plcprotech.com\/id\/products\/mitsubishi-electric-gt2710-vtbd-got2000-advanced-hmi-touch-screen","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}