{"product_id":"omron-c200he-cpu42-e-sysmac-c200he-cpu-module","title":"Omron C200HE-CPU42-E SYSMAC C200HE CPU Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eExecuting central execution and logical control within legacy industrial assemblies, the \u003cstrong\u003eOmron C200HE-CPU42-E\u003c\/strong\u003e is a high-reliability central processing unit engineered for the SYSMAC C200HX\/HG\/HE platform. This controller manages medium-scale discrete manufacturing processes, coordinating inputs and outputs across localized and distributed racks. It features a built-in RS-232C serial port, enabling native host link communication, operator interface connections, and direct programming connectivity without requiring separate communications modules. Its robust processing architecture and extensive instruction set make it a staple in classic assembly, packaging, and material handling automation networks.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIntegrated Communications:\u003c\/strong\u003e Standard built-in RS-232C port alongside a dedicated peripheral port simplifies configuration and SCADA system integration.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSubstantial Execution Speed:\u003c\/strong\u003e Fast basic instruction execution time optimized for deterministic machine control.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConfigurable Memory Architecture:\u003c\/strong\u003e Supports program and data memory storage to sustain comprehensive sequence instructions and logging variables.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModular Flexibility:\u003c\/strong\u003e Designed for slide-in installation on standard SYSMAC C200HW backplanes, easing deployment and repair cycles.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBattery-Backed Memory Protection:\u003c\/strong\u003e Active RAM backup preserves user program and data register states during system power down cycles.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAutomated Packaging Lines:\u003c\/strong\u003e Real-time coordination of high-speed filling, sealing, and labeling apparatus.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaterial Handling Systems:\u003c\/strong\u003e Managing complex conveyor sorting systems, diverters, and automated guided vehicles (AGVs).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAutomotive Assembly Sub-stations:\u003c\/strong\u003e Direct control of mechanical lifters, part feeders, and pneumatic clamping fixtures.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWater Treatment Plant Monitoring:\u003c\/strong\u003e Managing decentralized pump controllers, valve actuators, and instrumentation arrays.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eSpecification Parameter\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eValue \/ Rating\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eOmron Automation and Safety\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eModel Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eC200HE-CPU42-E\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eSeries\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eSYSMAC C200HX \/ C200HG \/ C200HE\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eProgram Capacity\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e7.2 Kwords\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eData Memory (DM) Capacity\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e6 Kwords\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eMaximum I\/O Capacity\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e880 I\/O points (when using expansion racks)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eBuilt-in Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e1 Peripheral Port, 1 RS-232C Port (D-Sub 9-pin)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eCurrent Consumption\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e0.70 A at 5 VDC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eBackup Battery\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eC200H-BAT09 (Typical life: 5 years at 25 degC)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eOperating Temperature Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e0 to 55 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eJapan\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 1.0kg;\"\u003e1.0 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003ePort \/ Terminal\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eInterface Type\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eFunctional Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003ePeripheral Port\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eCustom Omron Multi-pin\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eConnecting handheld programming consoles, standard programming cables (such as CQM1-CIF02), or interface conversion units.\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eRS-232C Port\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e9-pin Female D-Sub (DB9)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eHost Link protocol communications, peer-to-peer serial links, display terminal interfacing, or ASCII communications.\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eWhen migrating legacy networks, understand that the C200HE series replaces the older C200H series controllers (e.g., C200H-CPU01\/11). Program migration from standard C200H blocks to the C200HE platform can be executed seamlessly in CX-Programmer, though memory maps must be carefully cross-checked, as certain DM registers and holding relays have expanded allocations. Ensure that any specialized high-speed counter or motion modules used on the backplane are registered in the I\/O table configuration tool of the new CPU to prevent initialization faults.\u003c\/p\u003e\n\n\u003ch4\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eA common failure point in legacy setups is low-voltage battery degradation. If the module sits de-energized for extended periods, the C200H-BAT09 backup battery can deplete, leading to complete clearing of RAM memory (user logic and Retentive DM areas). It is highly recommended to log or write critical machine operational recipes to an external EEPROM memory cassette (such as the C200HW-ME432) to prevent program loss during sudden maintenance outages.\u003c\/p\u003e\n\n\u003ch4\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eFor reliable host serial communications over the built-in RS-232C port, standard commercial DB9 null-modem cables are often non-functional due to Omron's specific internal pin jumper requirements. You must construct or obtain a cable where Pin 4 (RTS) and Pin 5 (CTS) are shorted on the PLC side, or configure the CPU dip switches to override standard hardware handshaking, ensuring smooth serial transmission without timeout timeouts.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cp style=\"margin: 0; font-weight: bold; color: #9b2c2c;\"\u003eCRITICAL WARNING:\u003c\/p\u003e\n  \u003cp style=\"margin: 0; color: #9b2c2c;\"\u003eIsolate all upstream AC and DC control voltages powering the PLC backplane before mounting or unmounting the CPU module. Inserting or extracting modules with power active on the backplane will damage the CPU unit's bus contacts and can permanently corrupt internal flash storage.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"display: flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; min-width: 2rem; height: 2rem; border-radius: 50%; font-weight: bold;\"\u003e1\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748; padding-top: 0.25rem;\"\u003eAlign the guide tabs on the lower edge of the C200HE-CPU42-E module with the corresponding slots on the main backplane chassis.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"display: flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; min-width: 2rem; height: 2rem; border-radius: 50%; font-weight: bold;\"\u003e2\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748; padding-top: 0.25rem;\"\u003eCarefully pivot the top of the CPU module toward the backplane, pressing it firmly into place until the retention hooks click securely to guarantee complete multi-bus contact engagement.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"display: flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; min-width: 2rem; height: 2rem; border-radius: 50%; font-weight: bold;\"\u003e3\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748; padding-top: 0.25rem;\"\u003eSecure the module lock-screw at the top of the faceplate to stabilize the unit against ambient industrial vibration.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"display: flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; min-width: 2rem; height: 2rem; border-radius: 50%; font-weight: bold;\"\u003e4\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748; padding-top: 0.25rem;\"\u003eAttach the serial or peripheral communication cables, securing DB9 thumbscrews tightly to establish reliable shielding continuity.\u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":53077909602667,"sku":"C200HE-CPU42-E","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/C200HE-CPU42-E-o5xbcfl3qmy.png?v=1775733460","url":"https:\/\/www.plcprotech.com\/id\/products\/omron-c200he-cpu42-e-sysmac-c200he-cpu-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}