{"product_id":"omron-nx-pg0242-5-nx-series-pulse-output-unit","title":"Omron NX-PG0242-5 NX Series Pulse Output Unit","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eHigh-performance motion control applications require precise pulse train generation, which is delivered by the \u003cstrong\u003eNX-PG0242-5\u003c\/strong\u003e motion control module. Engineered as a high-density, 2-channel \u003cstrong\u003epulse output unit\u003c\/strong\u003e for the Omron Sysmac platform, this module provides line driver outputs compatible with PNP-type external interfaces. It integrates seamlessly into the NX-series I\/O system, enabling synchronized open-loop control of servo drives and stepper motor drives.\u003c\/p\u003e\n\n\u003cp\u003eUtilizing synchronous I\/O refreshing or task period prioritized refreshing, this unit ensures minimal jitter and deterministic execution of motion profiles. Connection is consolidated through a high-density MIL connector interface, reducing panel footprint and wiring complexity while maintaining high signal integrity for high-speed transmission.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eTwo independent pulse output channels for multi-axis positioning.\u003c\/li\u003e\n  \u003cli\u003eSupport for synchronous I\/O refreshing to coordinate motion tasks directly with the controller CPU cycle.\u003c\/li\u003e\n  \u003cli\u003eMultiple pulse output modes including Forward\/Reverse direction, Pulse + Direction, and Phase Differential (x1, x2, or x4 multiplication).\u003c\/li\u003e\n  \u003cli\u003eConsolidated wiring via a 34-terminal MIL connector interface.\u003c\/li\u003e\n  \u003cli\u003eIntegrated inputs and outputs (5 inputs and 5 outputs per channel) for limit switches, origin sensors, and auxiliary controls.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003ePackaging machinery and rotary indexing tables.\u003c\/li\u003e\n  \u003cli\u003eSemiconductor manufacturing and wafer handling systems.\u003c\/li\u003e\n  \u003cli\u003eHigh-speed pick-and-place gantry robots.\u003c\/li\u003e\n  \u003cli\u003eMulti-axis stepper and servo drive synchronization.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eManufacturer\u003c\/strong\u003e\n      \u003ctd\u003eOmron\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\n      \u003ctd\u003eNX-PG0242-5\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eSeries\u003c\/strong\u003e\n      \u003ctd\u003eNX Series\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eModule Type\u003c\/strong\u003e\n      \u003ctd\u003ePulse Output Unit (Line Driver Output, PNP type)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\n      \u003ctd\u003e2\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eControl Method\u003c\/strong\u003e\n      \u003ctd\u003eOpen-loop control through pulse string output\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003ePulse Output Form\u003c\/strong\u003e\n      \u003ctd\u003eLine driver output\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eVelocity Control Range\u003c\/strong\u003e\n      \u003ctd\u003e1 to 4,000,000 pps\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003ePosition Control Range\u003c\/strong\u003e\n      \u003ctd\u003e-2,147,483,648 to 2,147,483,647 pulses\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eInputs per Channel\u003c\/strong\u003e\n      \u003ctd\u003e5 external inputs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eOutputs per Channel\u003c\/strong\u003e\n      \u003ctd\u003e5 (1 forward pulse, 1 reverse pulse, 3 external outputs)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eI\/O Refreshing Method\u003c\/strong\u003e\n      \u003ctd\u003eSynchronous I\/O refreshing or task period prioritized refreshing\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eExternal Connection Type\u003c\/strong\u003e\n      \u003ctd\u003eMIL connector (34 terminals x 1)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eCurrent Consumption (I\/O Power Supply)\u003c\/strong\u003e\n      \u003ctd\u003e50 mA maximum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eLine Driver Cable Length\u003c\/strong\u003e\n      \u003ctd\u003e10 m maximum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eAuxiliary I\/O Cable Length\u003c\/strong\u003e\n      \u003ctd\u003e3 m maximum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\n      \u003ctd\u003e30 mm x 100 mm x 71 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eWeight\u003c\/strong\u003e\n      \u003ctd\u003e0.11 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Mount the module securely onto standard 35 mm DIN rail within the NX-series bus expansion assembly.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShielding:\u003c\/strong\u003e Use shielded twisted-pair (STP) cabling for all line driver pulse outputs to minimize electromagnetic interference (EMI).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCable Lengths:\u003c\/strong\u003e Ensure line driver output cables do not exceed 10 meters, and standard I\/O sensor cables are kept under 3 meters.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Ensure the DIN rail is connected to a protective ground (PE) terminal to maintain proper noise immunity.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":53077900394859,"sku":"NX-PG0242-5","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/nx-pg0242-5-rkgj5z13i4x.png?v=1775734007","url":"https:\/\/www.plcprotech.com\/id\/products\/omron-nx-pg0242-5-nx-series-pulse-output-unit","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}