{"product_id":"omron-nx701-z600-nx7-series-motion-controller","title":"Omron NX701-Z600 NX7 Series Motion Controller","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eReal-time mechanical coordination and machine-learning predictive analytics are executed simultaneously by the \u003cstrong\u003eOmron NX701-Z600\u003c\/strong\u003e motion controller, establishing it as a premier computational engine for complex, high-speed automated systems. Designed for applications requiring synchronized motion across high axis-counts, this advanced \u003cstrong\u003eOmron\u003c\/strong\u003e hardware integrates sequence, motion, and Artificial Intelligence processing into a single runtime environment. With a primary task cycle time of \u003cstrong\u003e0.125 ms\u003c\/strong\u003e and substantial system memory, this controller provides high-tier processing speed and deterministic control over extensive industrial Ethernet networks.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMulti-Axis Coordination:\u003c\/strong\u003e Manages up to 128 synchronous and virtual axes simultaneously.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAI Integration:\u003c\/strong\u003e On-board AI engine executes predictive maintenance algorithms and anomaly detection directly in the controller core.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Speed Processing:\u003c\/strong\u003e Achieves a primary task cycle time of 0.125 ms for ultra-fast response loops.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eExtensive Memory Capacity:\u003c\/strong\u003e Outfitted with 80 MB of program memory and 260 MB of variables memory to accommodate complex logic and data storage.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDual Ethernet Routing:\u003c\/strong\u003e Includes dual integrated EtherNet\/IP ports and a dedicated EtherCAT master port.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlexible Expansion:\u003c\/strong\u003e Direct high-speed connection to the Omron NX I\/O bus system.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eHigh-speed packaging, cartoning, and continuous-motion wrapping lines.\u003c\/li\u003e\n  \u003cli\u003eMulti-axis robotic synchronization and precision automotive assembly.\u003c\/li\u003e\n  \u003cli\u003eSemiconductor wafer handling and high-accuracy positioning systems.\u003c\/li\u003e\n  \u003cli\u003eContinuous web handling, high-speed printing presses, and tension control systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0; text-align: left;\"\u003e\n        \u003cth style=\"padding: 0.75rem;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 0.75rem;\"\u003eSpecification\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eOmron\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eNX701-Z600\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eController Series\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eSysmac NX7 Series\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eController Functionality\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eAI Control, Motion Control, Sequence Control\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePrimary Task Cycle Time\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e0.125 ms\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eProgram Memory Capacity\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e80 MB\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eVariables Memory Capacity\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e260 MB\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eMax. Synchronous Axes\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e128\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eMax. Axes (including virtual)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e128\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eCommunication Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eEtherCAT Master (1 port), EtherNet\/IP (2 ports), Ethernet TCP\/IP\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eLocal I\/O System\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eNX I\/O Bus\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eJapan\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e3.0 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0; text-align: left;\"\u003e\n        \u003cth style=\"padding: 0.75rem;\"\u003eConnector \/ Port\u003c\/th\u003e\n        \u003cth style=\"padding: 0.75rem;\"\u003eInterface \/ Circuit Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePORT 1 (RJ45)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eEtherNet\/IP (1 Gbps) - Support for Tag Data Links, FTP, and Sysmac Studio connection\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePORT 2 (RJ45)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eEtherNet\/IP (1 Gbps) - High-speed information network and auxiliary host communication\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePORT 3 (RJ45)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eEtherCAT Master - High-speed, deterministic connection for servo drives and remote I\/O\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePower Terminals\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e24 VDC Unit power supply inputs (including Functional Ground and Protective Ground)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eUSB Port\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eUSB 2.0 connection point for direct programming and firmware maintenance\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe \"Z\" suffix in the NX701-Z600 part code specifies the inclusion of Omron's real-time AI predictive engine. When replacing a standard NX701-1600 or NX701-1700 unit, note that you will require Sysmac Studio version 1.43 or higher to interface with the AI features. Migrating programs from non-AI NX7 controllers is straightforward, but you must manually configure the database links and analytics library blocks in your updated task list.\u003c\/p\u003e\n\n\u003ch4\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eExecuting real-time machine learning directly in the controller's runtime environment consumes additional computational cycles. To prevent watchdog timeout faults, keep your primary 0.125 ms motion loop dedicated solely to critical I\/O and axis synchronization, and assign the database writing and AI evaluation tasks to a lower-priority periodic task executing at 2.0 ms or higher.\u003c\/p\u003e\n\n\u003ch4\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eTo maintain the integrity of the EtherCAT 100BASE-TX deterministic communication channel, always implement Category 5e or Category 6 Double-Shielded Twisted Pair (S\/STP) cables. Route all industrial network cabling away from high-power servo motor power lines by a minimum of 100 mm. Ground the shielding at the metal frame of the entry panel to minimize high-frequency EMI noise.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 0.5rem;\"\u003eCRITICAL WARNING\u003c\/strong\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003eIsolate and lock out all AC\/DC power sources feeding the control enclosure before attempting to mount, wire, or service this unit. Failure to perform complete power de-energization can result in terminal damage, fieldbus network disruption, or severe electrical shock to personnel.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold;\"\u003e1\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748; padding-top: 0.2rem;\"\u003eMount the controller horizontally onto a symmetrical 35 mm DIN rail (such as TH35-7.5) inside an IP54 or higher industrial enclosure.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold;\"\u003e2\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748; padding-top: 0.2rem;\"\u003eConnect a heavy-gauge copper grounding conductor (minimum 2.0 mm square) directly to the protective ground terminal of the unit.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold;\"\u003e3\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748; padding-top: 0.2rem;\"\u003eWire the 24 VDC power supply to the main power terminals, ensuring correct polarity and utilizing crimped wire ferules.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold;\"\u003e4\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748; padding-top: 0.2rem;\"\u003eInsert the RJ45 EtherCAT master and EtherNet\/IP cables into their respective ports until you hear a positive locking click.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold;\"\u003e5\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748; padding-top: 0.2rem;\"\u003eVerify all connections, energize the 24 VDC supply, and utilize Sysmac Studio to perform the initial firmware and configuration upload.\u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":53077910815083,"sku":"NX701-Z600","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/nx701-z600-mdtbdgtxjfb.png?v=1775734052","url":"https:\/\/www.plcprotech.com\/id\/products\/omron-nx701-z600-nx7-series-motion-controller","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}