{"product_id":"siemens-6av3535-1fa01-0ax0-coros-op35-operator-panel","title":"Siemens 6AV3535-1FA01-0AX0 Coros OP35 Operator Panel","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThis Siemens 6AV3535-1FA01-0AX0 is an OP 35 Operator Panel from the Coros HMI series, designed for process monitoring and control in industrial automation systems. The unit features a \u003cstrong\u003emonochrome LC display\u003c\/strong\u003e with pixel graphics for clear data visualization. It provides extensive connectivity through \u003cstrong\u003efour integrated interfaces\u003c\/strong\u003e, including TTY\/V.24, X.27\/TTY, and MPI\/PPI. This model is supplied without a direct keypad, offering flexibility for custom mounting and integration into control cabinets or existing operator stations. As an obsolete part, it serves as a direct replacement for maintaining legacy systems.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; color: #2d3748;\"\u003e\n  \u003cli\u003eMonochrome Liquid Crystal Display (LCD) with pixel graphics.\u003c\/li\u003e\n  \u003cli\u003eFour integrated communication interfaces for versatile connectivity.\u003c\/li\u003e\n  \u003cli\u003eSupports TTY\/V.24, X.27\/TTY, and MPI\/PPI protocols.\u003c\/li\u003e\n  \u003cli\u003eDesigned without an integrated keypad for flexible system design.\u003c\/li\u003e\n  \u003cli\u003ePart of the Siemens Coros HMI product family.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; color: #2d3748;\"\u003e\n  \u003cli\u003eMachine control and process visualization.\u003c\/li\u003e\n  \u003cli\u003eLegacy system maintenance and spare parts replacement.\u003c\/li\u003e\n  \u003cli\u003eIndustrial production lines.\u003c\/li\u003e\n  \u003cli\u003eData entry and monitoring stations in manufacturing environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr\u003e\n        \u003cth style=\"border: 1px solid #e2e8f0; padding: 10px; text-align: left; background-color: #f7fafc; font-weight: 600;\"\u003eSpecification\u003c\/th\u003e\n        \u003cth style=\"border: 1px solid #e2e8f0; padding: 10px; text-align: left; background-color: #f7fafc; font-weight: 600;\"\u003eValue\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eBrand\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eSiemens\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e6AV3535-1FA01-0AX0\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eProduct Series\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eCoros HMI, OP35 Series\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eProduct Type\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eOperator Panel\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eDisplay Type\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eMonochrome LC Display (Pixel Graphics)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eIntegrated Interfaces\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e2 x TTY\/V.24, 1 x X.27\/TTY, 1 x MPI\/PPI\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eKeypad\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eNot included\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eProduct Lifecycle Status\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eObsolete\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eSuccessor Part Number\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e6AV3535-1FA01-1AX0\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e6.35 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003ePackage Dimensions (Source)\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e48.30 x 30.50 x 10.20 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e85371091\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eECCN\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eN\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eGermany (Estimated)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px; margin-top: 24px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"padding: 16px; background-color: #fff5f5; border-left: 5px solid #c53030; margin-bottom: 20px;\"\u003e\n  \u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e This product is obsolete. Before installation, verify complete compatibility with the existing control system, including software, hardware, and communication protocols. Incorrect integration can lead to system malfunction or equipment damage.\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0; color: #2d3748;\"\u003e\n  \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n    De-energize the entire control cabinet and associated machinery. Follow all local Lockout\/Tagout (LOTO) procedures to prevent accidental startup.\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n    Prepare the panel cutout according to the device's mechanical dimensions. Ensure the mounting surface is clean, flat, and provides adequate support.\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n    Secure the operator panel into the cutout using the appropriate mounting hardware. Ensure a proper seal is achieved if the application requires a specific IP rating.\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n    Connect the power supply wiring to the designated terminals. Verify the voltage matches the panel's requirements. Connect the functional earth (FE) or protective earth (PE) terminal to the cabinet's ground bus.\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e5\u003c\/span\u003e\n    Connect the communication cables (TTY, MPI\/PPI) to the corresponding ports. Route cables away from high-voltage lines to minimize electromagnetic interference. Use shielded cables where specified.\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e6\u003c\/span\u003e\n    After all connections are verified, remove LOTO devices and re-energize the system. Proceed with software configuration and communication testing.\n  \u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716683264363,"sku":"6AV3535-1FA01-0AX0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6av3535-1fa01-0ax0-r2yqscg0qvl_4c23e509-3290-4eb2-8443-0aacc5edec62.jpg?v=1767087946","url":"https:\/\/www.plcprotech.com\/id\/products\/siemens-6av3535-1fa01-0ax0-coros-op35-operator-panel","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}