{"product_id":"siemens-6av7240-6bd17-0aq3-simatic-ipc-477d-panel-pc","title":"Siemens 6AV7240-6BD17-0AQ3 SIMATIC IPC 477D Panel PC","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThis is a Siemens SIMATIC IPC 477D Panel PC, model 6AV7240-6BD17-0AQ3, an integrated human-machine interface (HMI) solution for demanding industrial environments. It features a \u003cstrong\u003e15-inch touch display\u003c\/strong\u003e and is powered by an Intel \u003cstrong\u003eCore i7-3517UE processor\u003c\/strong\u003e with \u003cstrong\u003e8 GB of RAM\u003c\/strong\u003e. This unit is configured without internal mass storage, allowing for flexible drive selection and replacement. It comes pre-loaded with a comprehensive software package including Windows 7 Ultimate, WinAC RTX F 2010 SP2, and WinCC RT Advanced licenses, making it suitable for complex visualization and real-time control tasks.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 10px;\"\u003e\n  \u003cli\u003e15-inch resistive touch display for operator interaction.\u003c\/li\u003e\n  \u003cli\u003ePowered by an Intel Core i7-3517UE dual-core processor.\u003c\/li\u003e\n  \u003cli\u003eEquipped with 8 GB of system memory.\u003c\/li\u003e\n  \u003cli\u003eDual Gigabit Ethernet ports for network connectivity (IE\/PN).\u003c\/li\u003e\n  \u003cli\u003eMultiple USB ports: four on the rear and one on the front for peripheral access.\u003c\/li\u003e\n  \u003cli\u003eIncludes one RS-232 serial port and one PCIe expansion slot.\u003c\/li\u003e\n  \u003cli\u003ePre-installed with Windows 7 Ultimate (64-bit) operating system.\u003c\/li\u003e\n  \u003cli\u003eBundled with WinAC RTX F 2010 SP2 and WinCC RT Advanced V13\/V15 software licenses.\u003c\/li\u003e\n  \u003cli\u003ePowered by a 110\/230V AC industrial power supply with NAMUR compliance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 10px;\"\u003e\n  \u003cli\u003eProcess visualization and control (SCADA\/HMI)\u003c\/li\u003e\n  \u003cli\u003eMachine-level data acquisition and logging\u003c\/li\u003e\n  \u003cli\u003eManufacturing Execution Systems (MES) terminals\u003c\/li\u003e\n  \u003cli\u003eIndustrial automation control panels\u003c\/li\u003e\n  \u003cli\u003ePC-based automation with software PLC requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n    \u003cthead style=\"background-color: #f2f2f2;\"\u003e\n      \u003ctr\u003e\n        \u003cth style=\"padding: 8px; border: 1px solid #ddd; text-align: left;\"\u003eSpecification\u003c\/th\u003e\n        \u003cth style=\"padding: 8px; border: 1px solid #ddd; text-align: left;\"\u003eValue\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSiemens\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eProduct Series\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSIMATIC IPC 477D\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e6AV7240-6BD17-0AQ3\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eDisplay\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e15-inch Touch Display\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eProcessor\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eIntel Core i7-3517UE\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eMemory (RAM)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e8 GB\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eInternal Storage\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eNot included (replaceable without drive)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eEthernet Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e2 x Gigabit Ethernet (10\/100\/1000 Mbps), IE\/PN compatible\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eUSB Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e4 x Rear, 1 x Front\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSerial Port\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e1 x RS-232\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eExpansion Slot\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e1 x PCIe\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eOperating System\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eWindows 7 Ultimate, 64-bit\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePre-installed Software\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eWinAC RTX F 2010 SP2; WinCC RT Advanced V13 SP1 512PT (incl. Logging and Recipes); WinCC RT Advanced V15 License Package\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePower Supply\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e110\/230V AC Industrial Power Supply with NAMUR\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eIncluded Accessories\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePower supply cable for USA\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eProduct Lifecycle Status\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePhase-Out\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e5.00 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e85371098\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eGermany (Estimate)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e48 cm x 40 cm x 20 cm (Estimate)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 5px solid #c53030; padding: 15px; margin: 15px 0;\"\u003e\n  \u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e Hazardous voltages are present. Installation must be performed by qualified personnel only. Failure to de-energize equipment and follow Lockout\/Tagout (LOTO) procedures before installation can result in severe injury or death. Use appropriate Personal Protective Equipment (PPE).\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0;\"\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n    \u003cdiv\u003e\n\u003cstrong\u003eSite Preparation:\u003c\/strong\u003e Ensure the panel cutout dimensions match the IPC 477D specifications. The mounting surface must be clean, flat, and capable of supporting the unit's weight. Maintain required clearance for ventilation and cable access.\u003c\/div\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n    \u003cdiv\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Insert the Panel PC into the prepared cutout from the front. Secure the unit from the rear using the provided mounting clamps. Tighten the clamp screws evenly in a cross-pattern to ensure a uniform seal against the panel gasket. Do not overtighten.\u003c\/div\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n    \u003cdiv\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Connect the protective earth (PE) terminal on the IPC chassis to the main control panel's protective earth bus using a low-impedance conductor. A proper ground connection is critical for safety and noise immunity.\u003c\/div\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n    \u003cdiv\u003e\n\u003cstrong\u003ePower Connection:\u003c\/strong\u003e Connect the provided AC power cable to the unit's power supply input. Ensure the source voltage (110V or 230V AC) matches the supply rating. Route the power cable separately from signal and communication cables to minimize interference.\u003c\/div\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e5\u003c\/span\u003e\n    \u003cdiv\u003e\n\u003cstrong\u003eI\/O and Network Cabling:\u003c\/strong\u003e Connect Ethernet, USB, and serial cables as required. Use shielded cables for all communication links. Ensure all connectors are fully seated and secured. Power on the unit only after all connections are made and verified.\u003c\/div\u003e\n  \u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716359516523,"sku":"6AV7240-6BD17-0AQ3","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6av7240-6bd17-0aq3-c4d2yzxy2cq_504c2cfd-ffbc-462f-b32f-3287a011162b.jpg?v=1767081238","url":"https:\/\/www.plcprotech.com\/id\/products\/siemens-6av7240-6bd17-0aq3-simatic-ipc-477d-panel-pc","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}