{"product_id":"siemens-6av7611-0aa20-0cg0-simatic-panel-pc-670-panel-pc","title":"Siemens 6AV7611-0AA20-0CG0 SIMATIC PANEL PC 670 Panel PC","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Siemens 6AV7611-0AA20-0CG0 is a SIMATIC PANEL PC 670 designed for industrial human-machine interface (HMI) and control applications. This standard configuration unit features a \u003cstrong\u003e10-inch TFT display\u003c\/strong\u003e, a \u003cstrong\u003e300 MHz Celeron CPU\u003c\/strong\u003e, \u003cstrong\u003e128 MB of RAM\u003c\/strong\u003e, and a \u003cstrong\u003e20 GB hard drive\u003c\/strong\u003e. It is equipped with a power supply compatible with \u003cstrong\u003e115-230V AC\u003c\/strong\u003e and comes pre-installed with a multi-language version of the Windows 2000 operating system. This model is supplied with a European mains cable for immediate deployment.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 0;\"\u003e\n  \u003cli\u003e10-inch TFT color display for clear process visualization.\u003c\/li\u003e\n  \u003cli\u003ePowered by a Celeron 300 MHz processor.\u003c\/li\u003e\n  \u003cli\u003eIncludes 128 MB of RAM and a 20 GB hard disk drive.\u003c\/li\u003e\n  \u003cli\u003eWide-range 115-230V AC power supply input.\u003c\/li\u003e\n  \u003cli\u003ePre-loaded with Windows 2000 (Multi-Language: EN, GER, FR, IT, SP).\u003c\/li\u003e\n  \u003cli\u003eRobust design suitable for industrial environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 0;\"\u003e\n  \u003cli\u003eMachine-level operator control and monitoring.\u003c\/li\u003e\n  \u003cli\u003eProcess visualization and data logging.\u003c\/li\u003e\n  \u003cli\u003eSupervisory Control and Data Acquisition (SCADA) nodes.\u003c\/li\u003e\n  \u003cli\u003eManufacturing Execution Systems (MES) terminals.\u003c\/li\u003e\n  \u003cli\u003eFactory floor automation control.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr\u003e\n        \u003cth style=\"background-color: #f7fafc; padding: 10px 12px; border: 1px solid #e2e8f0; text-align: left; color: #2d3748; font-weight: 600;\"\u003eSpecification\u003c\/th\u003e\n        \u003cth style=\"background-color: #f7fafc; padding: 10px 12px; border: 1px solid #e2e8f0; text-align: left; color: #2d3748; font-weight: 600;\"\u003eValue\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eBrand\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eSiemens\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eProduct Series\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eSIMATIC Panel PC 670\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eDisplay\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003e10-inch TFT\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eProcessor (CPU)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eCeleron 300 MHz\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eMemory (RAM)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003e128 MB\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eStorage\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003e20 GB Hard Drive (HD)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eOperating System\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eWindows 2000 Multi-Language (EN, GER, FR, IT, SP)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003ePower Supply\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003e115-230 V AC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eIncluded Cable\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eEuropean Mains Cable\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eProduct Lifecycle Status\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eObsolete\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003e4.00 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003e85371091\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eECCN\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eN\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eGermany (Estimated)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003eSiemens\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px 12px; border: 1px solid #e2e8f0;\"\u003e40 x 35 x 20 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-top: 24px; margin-bottom: 16px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 16px; margin-bottom: 20px;\"\u003e\n  \u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e Electrical hazard. This equipment must be installed and serviced by qualified personnel only. De-energize all power sources and follow Lockout\/Tagout (LOTO) procedures before performing any installation, wiring, or maintenance. Failure to comply can result in severe injury or death.\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0;\"\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #fff; border-radius: 50%; width: 24px; height: 24px; min-width: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px;\"\u003e1\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003ePrepare Mounting Location:\u003c\/strong\u003e Ensure the panel cutout dimensions are correct. Verify that the mounting surface is flat, clean, and can support the weight of the unit. Allow for adequate ventilation clearance around the back of the PC to prevent overheating.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #fff; border-radius: 50%; width: 24px; height: 24px; min-width: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px;\"\u003e2\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003eMount the Panel PC:\u003c\/strong\u003e Insert the Panel PC into the cutout from the front. Secure it from the rear using the provided mounting clamps. Tighten the clamps evenly in a diagonal sequence to ensure a uniform seal against the panel gasket. Do not overtighten.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #fff; border-radius: 50%; width: 24px; height: 24px; min-width: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px;\"\u003e3\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003eConnect Power:\u003c\/strong\u003e Before connecting, confirm the facility supply voltage matches the 115-230V AC rating of the Panel PC. Connect the provided mains cable to the unit's power inlet and to a properly grounded, stable power source. Ensure the power source is protected by an appropriate circuit breaker.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #fff; border-radius: 50%; width: 24px; height: 24px; min-width: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px;\"\u003e4\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003eEstablish Ground Connection:\u003c\/strong\u003e Connect the dedicated protective earth (PE) terminal on the Panel PC chassis to the main system ground or cabinet ground bus using a low-impedance conductor. A reliable ground connection is critical for safety and noise immunity.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #fff; border-radius: 50%; width: 24px; height: 24px; min-width: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px;\"\u003e5\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003eConnect Peripherals:\u003c\/strong\u003e Connect necessary peripherals such as keyboards, mice, and network cables to the appropriate I\/O ports. Route all cables to avoid strain and interference from high-power lines. Power on the unit and proceed with software configuration.\u003c\/span\u003e\n  \u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716400247147,"sku":"6AV7611-0AA20-0CG0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6av7611-0aa20-0cg0-m31crwhh00j_dfe2b12d-a782-4b3c-95a9-65f63e9fdc9d.jpg?v=1767082066","url":"https:\/\/www.plcprotech.com\/id\/products\/siemens-6av7611-0aa20-0cg0-simatic-panel-pc-670-panel-pc","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}