{"product_id":"siemens-6av7613-0af22-0cf0-simatic-panel-pc-670","title":"Siemens 6AV7613-0AF22-0CF0 SIMATIC Panel PC 670","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Siemens 6AV7613-0AF22-0CF0 is a SIMATIC Panel PC 670 designed for industrial human-machine interface (HMI) and control applications. This unit features a \u003cstrong\u003e12-inch TFT display\u003c\/strong\u003e and is powered by a \u003cstrong\u003ePentium III 500 MHz CPU\u003c\/strong\u003e. The standard configuration includes \u003cstrong\u003e128 MB of RAM\u003c\/strong\u003e, a \u003cstrong\u003e40 GB hard drive\u003c\/strong\u003e, and an integrated CD-ROM drive. It is supplied with a pre-installed English version of the Windows 98 operating system and includes a European mains cable for power connection.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px;\"\u003e\n  \u003cli\u003e12-inch TFT color display for process visualization.\u003c\/li\u003e\n  \u003cli\u003eIntel Pentium III processor operating at 500 MHz.\u003c\/li\u003e\n  \u003cli\u003e128 MB of installed system RAM.\u003c\/li\u003e\n  \u003cli\u003e40 GB hard disk drive for operating system and application storage.\u003c\/li\u003e\n  \u003cli\u003eIntegrated CD-ROM drive for software installation and data access.\u003c\/li\u003e\n  \u003cli\u003ePre-loaded with Microsoft Windows 98 (English).\u003c\/li\u003e\n  \u003cli\u003eSupports a wide input voltage range of 115-230V AC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px;\"\u003e\n  \u003cli\u003eMachine-level operator control and monitoring\u003c\/li\u003e\n  \u003cli\u003eProcess visualization and data logging\u003c\/li\u003e\n  \u003cli\u003eSupervisory Control and Data Acquisition (SCADA) nodes\u003c\/li\u003e\n  \u003cli\u003eIndustrial automation control panels\u003c\/li\u003e\n  \u003cli\u003eManufacturing execution systems (MES) terminals\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n    \u003cthead style=\"background-color: #f2f2f2;\"\u003e\n      \u003ctr\u003e\n        \u003cth style=\"padding: 8px; border: 1px solid #ddd; text-align: left;\"\u003eSpecification\u003c\/th\u003e\n        \u003cth style=\"padding: 8px; border: 1px solid #ddd; text-align: left;\"\u003eValue\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eBrand\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSiemens\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eProduct Series\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSIMATIC Panel PC 670\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePart Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e6AV7613-0AF22-0CF0\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eProduct Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePanel PC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eProduct Lifecycle Status\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eObsolete\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eDisplay\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e12-inch TFT\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCPU\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePentium III, 500 MHz\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eMemory (RAM)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e128 MB\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eStorage\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e40 GB Hard Drive (HD)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eOptical Drive\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCD-ROM\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eOperating System\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eWindows 98 (English)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eInput Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e115 - 230 V AC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eIncluded Accessories\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eEuropean Mains Cable\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eGermany (Estimate)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSiemens\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e35.0 x 25.0 x 25.0 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e12.00 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eHarmonized Tariff Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e85371091\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eECCN\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eN (No License Required)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 5px solid #c53030; padding: 15px; margin: 15px 0;\"\u003e\n  \u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e Hazardous voltages are present. Installation must be performed by qualified personnel only. Ensure all power sources are de-energized and locked out\/tagged out (LOTO) before beginning any work. Failure to comply can result in severe injury or death.\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0;\"\u003e\n  \u003cli style=\"margin-bottom: 10px; display: flex; align-items: center;\"\u003e\n    \u003cspan style=\"display: inline-block; text-align: center; line-height: 24px; font-weight: bold; color: white; background-color: #2b6cb0; border-radius: 50%; width: 24px; height: 24px; margin-right: 10px;\"\u003e1\u003c\/span\u003e\n    Verify that the panel cutout dimensions match the PC 670's mounting requirements. Ensure the mounting surface is clean, flat, and can support the unit's weight.\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 10px; display: flex; align-items: center;\"\u003e\n    \u003cspan style=\"display: inline-block; text-align: center; line-height: 24px; font-weight: bold; color: white; background-color: #2b6cb0; border-radius: 50%; width: 24px; height: 24px; margin-right: 10px;\"\u003e2\u003c\/span\u003e\n    Insert the Panel PC into the cutout from the front of the enclosure. Secure it from the rear using the provided mounting clamps, tightening them evenly to the manufacturer's specified torque to ensure a proper seal.\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 10px; display: flex; align-items: center;\"\u003e\n    \u003cspan style=\"display: inline-block; text-align: center; line-height: 24px; font-weight: bold; color: white; background-color: #2b6cb0; border-radius: 50%; width: 24px; height: 24px; margin-right: 10px;\"\u003e3\u003c\/span\u003e\n    Connect a low-impedance protective earth (PE) ground wire to the designated grounding terminal on the Panel PC chassis. This is critical for electrical safety and noise immunity.\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 10px; display: flex; align-items: center;\"\u003e\n    \u003cspan style=\"display: inline-block; text-align: center; line-height: 24px; font-weight: bold; color: white; background-color: #2b6cb0; border-radius: 50%; width: 24px; height: 24px; margin-right: 10px;\"\u003e4\u003c\/span\u003e\n    Connect all required communication, I\/O, and peripheral cables. Ensure proper cable strain relief and routing to prevent damage and interference.\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 10px; display: flex; align-items: center;\"\u003e\n    \u003cspan style=\"display: inline-block; text-align: center; line-height: 24px; font-weight: bold; color: white; background-color: #2b6cb0; border-radius: 50%; width: 24px; height: 24px; margin-right: 10px;\"\u003e5\u003c\/span\u003e\n    Connect the mains power cable to a stable, correctly rated power source. Only after all other connections are secure and the enclosure is closed should power be restored.\n  \u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52715824185707,"sku":"6AV7613-0AF22-0CF0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6av7613-0af22-0cf0-uvty40w2xjt_e5998569-9283-4b84-bc9b-edc7137dd62e.jpg?v=1767071855","url":"https:\/\/www.plcprotech.com\/id\/products\/siemens-6av7613-0af22-0cf0-simatic-panel-pc-670","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}