{"product_id":"siemens-6av7614-0af30-0ah0-simatic-panel-pc-670","title":"Siemens 6AV7614-0AF30-0AH0 SIMATIC Panel PC 670","description":"\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; color: #1a365d;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThis is a Siemens SIMATIC Panel PC 670, model 6AV7614-0AF30-0AH0, designed for human-machine interface (HMI) and control applications in industrial settings. The unit features a \u003cstrong\u003e15-inch TFT touch display\u003c\/strong\u003e for operator interaction. It is equipped with a \u003cstrong\u003e300 MHz Celeron processor\u003c\/strong\u003e, \u003cstrong\u003e256 MB of RAM\u003c\/strong\u003e, and a \u003cstrong\u003e40 GB hard drive\u003c\/strong\u003e for data storage and application execution. This specific configuration includes an integrated CD-ROM drive and requires a \u003cstrong\u003e24 V DC\u003c\/strong\u003e power source. The system comes with a pre-installed German language version of Windows NT 4.0. Please note that this product is considered obsolete by the manufacturer, making it suitable for legacy system maintenance and spare parts inventory.\u003c\/p\u003e\n\n\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-top: 24px; color: #1a365d;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: none; padding-left: 0;\"\u003e\n\u003cli\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0;\"\u003e\u003c\/span\u003e15-inch TFT color display with touch functionality\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0;\"\u003e\u003c\/span\u003ePowered by a 300 MHz Celeron CPU\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0;\"\u003e\u003c\/span\u003eStandard configuration with 256 MB RAM\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0;\"\u003e\u003c\/span\u003eIncludes a 40 GB hard drive and an integrated CD-ROM drive\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0;\"\u003e\u003c\/span\u003eOperates on a 24 V DC power supply\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0;\"\u003e\u003c\/span\u003ePre-installed with Windows NT 4.0 (German language)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-top: 24px; color: #1a365d;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: none; padding-left: 0;\"\u003e\n\u003cli\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0;\"\u003e\u003c\/span\u003eHuman-Machine Interface (HMI) for process visualization\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0;\"\u003e\u003c\/span\u003eMachine-level data acquisition and logging\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0;\"\u003e\u003c\/span\u003eSupervisory control in manufacturing and automation cells\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 5px; height: 8px; width: 8px; background-color: #2b6cb0;\"\u003e\u003c\/span\u003eReplacement unit for existing SIMATIC PC 670 installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-top: 24px; color: #1a365d;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"border: 1px solid #e2e8f0; padding: 10px; background-color: #f7fafc;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #e2e8f0; padding: 10px; background-color: #f7fafc;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px; background-color: #f7fafc;\"\u003eProduct Series\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px; background-color: #f7fafc;\"\u003eSIMATIC Panel PC 670\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003ePart Number\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e6AV7614-0AF30-0AH0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px; background-color: #f7fafc;\"\u003eDisplay\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px; background-color: #f7fafc;\"\u003e15-inch TFT Touch Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eProcessor (CPU)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eCeleron 300 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px; background-color: #f7fafc;\"\u003eMemory (RAM)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px; background-color: #f7fafc;\"\u003e256 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eStorage\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e40 GB Hard Drive (HD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px; background-color: #f7fafc;\"\u003eOptical Drive\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px; background-color: #f7fafc;\"\u003eCD-ROM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px; background-color: #f7fafc;\"\u003eOperating System\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px; background-color: #f7fafc;\"\u003eWindows NT 4.0 (German)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eProduct Lifecycle Status\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eObsolete\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px; background-color: #f7fafc;\"\u003eShipping Weight\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px; background-color: #f7fafc;\"\u003e4.00 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eCommodity Code\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e85371091\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px; background-color: #f7fafc;\"\u003eECCN\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px; background-color: #f7fafc;\"\u003eN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eGermany (Estimated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px; background-color: #f7fafc;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px; background-color: #f7fafc;\"\u003e48 x 38 x 15 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-top: 24px; color: #1a365d;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"border: 1px solid #fed7d7; border-left: 5px solid #c53030; background-color: #fff5f5; padding: 15px; margin-bottom: 20px;\"\u003e\n\u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e Disconnect and lock out all power sources to the control panel or cabinet before beginning installation. Failure to de-energize equipment can result in severe electrical shock, injury, or death. All work must be performed by qualified personnel.\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0; counter-reset: step-counter;\"\u003e\n\u003cli style=\"position: relative; padding-left: 45px; margin-bottom: 15px; min-height: 30px;\"\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 0; display: flex; align-items: center; justify-content: center; width: 30px; height: 30px; background-color: #2b6cb0; color: white; border-radius: 50%; font-weight: bold; counter-increment: step-counter; content: counter(step-counter);\"\u003e1\u003c\/span\u003e\nPrepare the panel cutout according to the device's mechanical specifications. Ensure the mounting surface is clean, flat, and free of burrs or debris.\n\u003c\/li\u003e\n\u003cli style=\"position: relative; padding-left: 45px; margin-bottom: 15px; min-height: 30px;\"\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 0; display: flex; align-items: center; justify-content: center; width: 30px; height: 30px; background-color: #2b6cb0; color: white; border-radius: 50%; font-weight: bold; counter-increment: step-counter; content: counter(step-counter);\"\u003e2\u003c\/span\u003e\nInsert the Panel PC into the cutout from the front of the panel. Verify that the gasket provides a complete seal against the enclosure surface to maintain the required environmental protection rating.\n\u003c\/li\u003e\n\u003cli style=\"position: relative; padding-left: 45px; margin-bottom: 15px; min-height: 30px;\"\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 0; display: flex; align-items: center; justify-content: center; width: 30px; height: 30px; background-color: #2b6cb0; color: white; border-radius: 50%; font-weight: bold; counter-increment: step-counter; content: counter(step-counter);\"\u003e3\u003c\/span\u003e\nFrom the rear of the panel, install and tighten the mounting clamps evenly in a star pattern. Apply torque incrementally to ensure uniform pressure on the gasket and prevent warping of the bezel.\n\u003c\/li\u003e\n\u003cli style=\"position: relative; padding-left: 45px; margin-bottom: 15px; min-height: 30px;\"\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 0; display: flex; align-items: center; justify-content: center; width: 30px; height: 30px; background-color: #2b6cb0; color: white; border-radius: 50%; font-weight: bold; counter-increment: step-counter; content: counter(step-counter);\"\u003e4\u003c\/span\u003e\nConnect the 24 V DC power supply to the designated terminals, ensuring correct polarity. Connect the main protective earth (PE) conductor to the chassis grounding point.\n\u003c\/li\u003e\n\u003cli style=\"position: relative; padding-left: 45px; margin-bottom: 15px; min-height: 30px;\"\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 0; display: flex; align-items: center; justify-content: center; width: 30px; height: 30px; background-color: #2b6cb0; color: white; border-radius: 50%; font-weight: bold; counter-increment: step-counter; content: counter(step-counter);\"\u003e5\u003c\/span\u003e\nConnect all required communication and I\/O cables. Ensure cables are routed with adequate strain relief and are separated from high-voltage power lines to minimize electrical noise.\n\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52715887198571,"sku":"6AV7614-0AF30-0AH0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6av7614-0af30-0ah0-iugx10v1bcr_1f138cad-bcdc-4e4f-9be8-d63e976367d9.jpg?v=1767073881","url":"https:\/\/www.plcprotech.com\/id\/products\/siemens-6av7614-0af30-0ah0-simatic-panel-pc-670","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}