{"product_id":"siemens-6av7803-1bb10-2ac0-simatic-panel-pc-677","title":"Siemens 6AV7803-1BB10-2AC0 SIMATIC Panel PC 677","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Siemens \u003cstrong\u003e6AV7803-1BB10-2AC0\u003c\/strong\u003e is a \u003cstrong\u003eSIMATIC Panel PC 677\u003c\/strong\u003e, an industrial panel computer designed for visualization and control tasks in automation environments. This unit features a 15-inch display with a resolution of 1024x768 pixels and is equipped with a Pentium M770 processor operating at 1.6 GHz. It includes 512MB of DDR266 SDRAM, an 80 GByte SATA hard drive, and a 3.5\" DVD+-RW+-R optical drive. The system operates on AC 110-230V power and comes pre-installed with Windows XP Professional MUI, supporting multiple languages.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e15-inch display with 1024x768 resolution\u003c\/li\u003e\n  \u003cli\u003ePentium M770 \/ 1.6 GHz processor\u003c\/li\u003e\n  \u003cli\u003e533 MHz Front Side Bus (FSB)\u003c\/li\u003e\n  \u003cli\u003e2MB Secondary Level Cache (SLC)\u003c\/li\u003e\n  \u003cli\u003e512MB DDR266 SDRAM (1x512MB configuration)\u003c\/li\u003e\n  \u003cli\u003e80 GByte SATA Hard Drive\u003c\/li\u003e\n  \u003cli\u003e3.5\" DVD+-RW+-R optical drive\u003c\/li\u003e\n  \u003cli\u003ePre-installed Windows XP Professional MUI (Multi-User Interface) supporting English, German, French, Italian, Spanish, Japanese, Chinese, and Korean\u003c\/li\u003e\n  \u003cli\u003eAC 110-230V power input with Europe power cable\u003c\/li\u003e\n  \u003cli\u003eWithout front-side USB interface\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThe Siemens SIMATIC Panel PC 677 is suitable for a range of industrial applications requiring robust computing and visualization capabilities, including:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eHuman Machine Interface (HMI) for machine and plant operation\u003c\/li\u003e\n  \u003cli\u003eProcess visualization and control in manufacturing and process industries\u003c\/li\u003e\n  \u003cli\u003eData acquisition and logging\u003c\/li\u003e\n  \u003cli\u003eSupervisory Control and Data Acquisition (SCADA) systems\u003c\/li\u003e\n  \u003cli\u003eIndustrial workstation for production monitoring and management\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n  \u003ctable border=\"1\" style=\"width:100%; border-collapse: collapse;\"\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; background-color: #f2f2f2;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; background-color: #f2f2f2;\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eBrand\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSiemens\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eManufacturer\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSiemens\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eRange\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSIMATIC Panel PC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSubrange\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePC677\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eProduct Type\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePanel PC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eDisplay Size\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e15 inch\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eResolution\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e1024x768\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCPU\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePentium M770 \/ 1.6 GHz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eFSB\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e533 MHz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSLC\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e2MB\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eRAM\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e512MB DDR266 SDRAM (1x512MB)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eStorage\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e80 GByte SATA Hard Drive\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eOptical Drive\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e3.5\" DVD+-RW+-R\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eOperating System\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eWindows XP Professional MUI (EN,GE,FR,IT,SP,JP,CHN,KOR)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePower Input\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eAC 110-230V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eUSB Interface\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eWithout Front Side USB\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePower Cable\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eEurope\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eProduct Phase\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eObsolete\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e67.00 x 83.00 x 11.50 cm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eShipping Weight\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e17.00 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCommodity Code\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e85371098\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eExport Control Regulations (ECCN)\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eN\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDe-energize System:\u003c\/strong\u003e Before beginning any installation or maintenance, ensure that all power to the system and associated equipment is disconnected and locked out according to safety procedures.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e The Panel PC is typically designed for panel mounting. Ensure the cutout dimensions in the control cabinet door or panel match the device's specifications. Secure the unit using the provided mounting clamps or screws, ensuring a tight seal to maintain the enclosure's IP rating.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Connection:\u003c\/strong\u003e Connect the AC 110-230V power supply to the designated power input terminals. Use the appropriate power cable for Europe as specified. Verify correct voltage and polarity before applying power.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Establish a proper protective earth (PE) connection to the designated grounding terminal on the Panel PC chassis. This is crucial for electrical safety and electromagnetic compatibility (EMC).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePeripheral Connections:\u003c\/strong\u003e Connect necessary peripherals such as keyboards, mice, and network cables. Note that this specific model does not feature a front-side USB interface; utilize rear or internal ports as available.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnvironmental Considerations:\u003c\/strong\u003e Install the Panel PC in an environment that adheres to its specified operating temperature, humidity, and vibration limits. Ensure adequate ventilation to prevent overheating.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCable Management:\u003c\/strong\u003e Route all cables neatly and securely, separating power cables from signal cables to minimize interference. Use cable ties and conduits where appropriate.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInitial Power-Up:\u003c\/strong\u003e After all connections are verified, re-energize the system. Observe the Panel PC for proper boot-up and functionality.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716379865451,"sku":"6AV7803-1BB10-2AC0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6av7803-1bb10-2ac0-ow1kznine1a_7a6c3659-ef3d-4196-97ce-67eb25f9b7e1.jpg?v=1767081638","url":"https:\/\/www.plcprotech.com\/id\/products\/siemens-6av7803-1bb10-2ac0-simatic-panel-pc-677","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}