{"product_id":"siemens-6av7823-0ab20-1ac0-simatic-panel-pc-577","title":"Siemens 6AV7823-0AB20-1AC0 SIMATIC Panel PC 577","description":"\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; color: #1a365d;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThis is the Siemens 6AV7823-0AB20-1AC0, a robust Panel PC from the SIMATIC PC 577 series designed for industrial automation applications. It features a \u003cstrong\u003e15-inch display\u003c\/strong\u003e with an integrated keypad, a screen resolution of \u003cstrong\u003e1024 x 768 pixels\u003c\/strong\u003e, and is powered by an Intel \u003cstrong\u003ePentium 4 processor at 2.4 GHz\u003c\/strong\u003e. The system is configured with \u003cstrong\u003e1 GB of DDR 400 RAM\u003c\/strong\u003e and includes a DVD-ROM drive. This unit comes pre-installed with Microsoft Windows XP Professional SP2 (Multi-User Interface), providing a stable platform for HMI and control tasks. Please note that this product line is considered obsolete by the manufacturer.\u003c\/p\u003e\n\n\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; color: #1a365d;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; padding-left: 20px;\"\u003e\n\u003cli\u003e15-inch display with integrated keypad for operator input\u003c\/li\u003e\n\u003cli\u003e1024 x 768 pixel screen resolution for clear visualization\u003c\/li\u003e\n\u003cli\u003eIntel Pentium 4 processor operating at 2.4 GHz\u003c\/li\u003e\n\u003cli\u003e1 GB of DDR 400 system memory\u003c\/li\u003e\n\u003cli\u003eIntegrated DVD-ROM drive for software installation and data access\u003c\/li\u003e\n\u003cli\u003ePre-installed with Microsoft Windows XP Professional SP2 (MUI)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; color: #1a365d;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; padding-left: 20px;\"\u003e\n\u003cli\u003eHuman-Machine Interface (HMI) for process control\u003c\/li\u003e\n\u003cli\u003eData acquisition and logging systems\u003c\/li\u003e\n\u003cli\u003eMachine-level visualization and operation\u003c\/li\u003e\n\u003cli\u003eSupervisory control in manufacturing environments\u003c\/li\u003e\n\u003cli\u003eReplacement for legacy systems requiring Windows XP compatibility\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; color: #1a365d;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"border: 1px solid #cbd5e0; padding: 8px; text-align: left; background-color: #f7fafc;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #cbd5e0; padding: 8px; text-align: left; background-color: #f7fafc;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003e6AV7823-0AB20-1AC0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eSeries\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eSIMATIC Panel PC 577\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003ePanel PC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eDisplay\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003e15-inch with Keys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eResolution\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003e1024 x 768 pixels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eProcessor\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eIntel Pentium 4, 2.4 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eMemory (RAM)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003e1 GB DDR 400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eOptical Drive\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eDVD-ROM Drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eOperating System\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eMicrosoft Windows XP Professional MUI SP2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eProduct Lifecycle Status\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eObsolete\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eCommodity Code\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003e85371091\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eExport Control (ECCN)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eShipping Weight\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003e15.00 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eGermany (Estimate)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #cbd5e0; padding: 8px;\"\u003e64.0 cm x 64.0 cm x 42.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; color: #1a365d;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 5px solid #c53030; padding: 15px; margin: 15px 0;\"\u003e\n\u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e Hazardous voltages are present within industrial control panels. All installation and maintenance activities must be performed by qualified personnel who are familiar with local safety codes and regulations. Failure to de-energize equipment before work can result in severe injury or death.\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0;\"\u003e\n\u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eDe-energize Equipment:\u003c\/strong\u003e Before beginning installation, disconnect all power sources to the control cabinet. Apply Lockout\/Tagout (LOTO) procedures to prevent accidental re-energization. Verify the absence of voltage with a properly rated meter.\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n\u003cdiv\u003e\n\u003cstrong\u003ePrepare Panel Cutout:\u003c\/strong\u003e Verify that the panel cutout dimensions match the requirements for the PC 577 chassis. Ensure the mounting surface is clean, flat, and rigid enough to support the unit's weight.\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eMount the Unit:\u003c\/strong\u003e Carefully insert the Panel PC into the cutout from the front of the panel. Secure it from the rear using the provided mounting clamps, tightening them evenly to ensure a proper seal against the enclosure gasket. Do not over-torque the clamps.\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eConnect Cabling:\u003c\/strong\u003e Connect the main power supply cable to the designated input terminal. Connect all required communication (e.g., Ethernet, PROFIBUS) and peripheral (e.g., USB) cables. Ensure all connectors are fully seated and secured.\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e5\u003c\/span\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eEstablish Ground Connection:\u003c\/strong\u003e Connect the chassis grounding terminal to the main panel protective earth (PE) bus bar using a low-impedance conductor. A reliable ground connection is critical for safety and noise immunity.\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 10px; flex-shrink: 0;\"\u003e6\u003c\/span\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eFinal Checks and Power-Up:\u003c\/strong\u003e After all connections are made and verified, remove LOTO devices and restore power to the cabinet. Power on the Panel PC and confirm that the operating system boots correctly and all connected peripherals are recognized.\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52715843977579,"sku":"6AV7823-0AB20-1AC0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/simatic-panel-pc-577-15-keys-10-ljvxta41nej_0cacb6e2-41c0-44ca-95fa-e3bbc3a4be14.jpg?v=1767072400","url":"https:\/\/www.plcprotech.com\/id\/products\/siemens-6av7823-0ab20-1ac0-simatic-panel-pc-577","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}