{"product_id":"siemens-6av7872-0af32-1ac0-simatic-panel-pc-677b","title":"Siemens 6AV7872-0AF32-1AC0 SIMATIC Panel PC 677B","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Siemens \u003cstrong\u003e6AV7872-0AF32-1AC0\u003c\/strong\u003e is a \u003cstrong\u003eSIMATIC Panel PC 677B\u003c\/strong\u003e, an industrial panel computer designed for visualization and control tasks. This unit features a 15-inch touch display with a resolution of 1024 x 768 pixels, making it suitable for human-machine interface (HMI) applications in various industrial environments. It is powered by a Core 2 Duo T7400 processor running at 2.16 GHz, supported by 2 GB of DDR2 RAM.\u003c\/p\u003e\n\u003cp\u003eConnectivity options include two 10\/100\/1000 Mbit\/s Ethernet ports, four USB V2.0 ports (with one conveniently located on the front side), and one serial (COM1) interface. For industrial communication, it integrates PROFIBUS\/MP. Storage is managed via a RAID1 configuration with two 250 GB SATA (2.5\") hard drives and includes a DVD+-R+-RW drive. The system operates on a DC 24V power supply and comes pre-installed with Windows XP Professional MUI, supporting multiple languages.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n    \u003cli\u003e15-inch Touch Display with 1024 x 768 Resolution\u003c\/li\u003e\n    \u003cli\u003eCore 2 Duo T7400 Processor, 2.16 GHz\u003c\/li\u003e\n    \u003cli\u003e2 GB DDR2 RAM\u003c\/li\u003e\n    \u003cli\u003eRAID1 Storage with 2x 250 GB SATA (2.5\") HDDs and DVD+-R+-RW\u003c\/li\u003e\n    \u003cli\u003e2x 10\/100\/1000 Mbit\/s Ethernet Ports\u003c\/li\u003e\n    \u003cli\u003e4x USB V2.0 Ports (including 1x front-side)\u003c\/li\u003e\n    \u003cli\u003e1x Serial (COM1) Interface\u003c\/li\u003e\n    \u003cli\u003ePROFIBUS\/MP Communication Support\u003c\/li\u003e\n    \u003cli\u003eDC 24V Power Supply\u003c\/li\u003e\n    \u003cli\u003eWindows XP Professional MUI Pre-installed\u003c\/li\u003e\n    \u003cli\u003e1x PCI and 1x PCIe x4 Expansion Slots\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThe SIMATIC Panel PC 677B is typically deployed in industrial settings requiring robust computing and visualization capabilities. Common applications include:\u003c\/p\u003e\n\u003cul\u003e\n    \u003cli\u003eProcess visualization and control in manufacturing plants.\u003c\/li\u003e\n    \u003cli\u003eOperator interface for machinery and automated systems.\u003c\/li\u003e\n    \u003cli\u003eData acquisition and monitoring systems.\u003c\/li\u003e\n    \u003cli\u003eSupervisory control and data acquisition (SCADA) systems.\u003c\/li\u003e\n    \u003cli\u003eEmbedded control solutions requiring a graphical interface.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n    \u003ctable style=\"width:100%; border-collapse: collapse; border: 1px solid #ddd;\"\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd; background-color: #f2f2f2;\"\u003eManufacturer\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSiemens\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd; background-color: #f2f2f2;\"\u003eProduct Series\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSIMATIC Panel PC\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd; background-color: #f2f2f2;\"\u003eSubrange\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePC677B\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd; background-color: #f2f2f2;\"\u003eModel Number\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e6AV7872-0AF32-1AC0\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd; background-color: #f2f2f2;\"\u003eProduct Type\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePanel PC\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd; background-color: #f2f2f2;\"\u003eDisplay Size\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e15\" Touch\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd; background-color: #f2f2f2;\"\u003eDisplay Resolution\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e1024 x 768\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd; background-color: #f2f2f2;\"\u003eProcessor\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCore 2 Duo T7400, 2.16 GHz\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd; background-color: #f2f2f2;\"\u003eCache\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e4MB SLC\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd; background-color: #f2f2f2;\"\u003eRAM\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e2 GB DDR2\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd; background-color: #f2f2f2;\"\u003eStorage Configuration\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eRAID1, 2x 250 GB SATA (2.5\") HDD\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd; background-color: #f2f2f2;\"\u003eOptical Drive\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eDVD+-R+-RW\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd; background-color: #f2f2f2;\"\u003eEthernet Ports\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e2x 10\/100\/1000 Mbit\/s\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd; background-color: #f2f2f2;\"\u003eUSB Ports\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e4x USB V2.0 (1x front-side)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd; background-color: #f2f2f2;\"\u003eSerial Ports\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e1x (COM1)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd; background-color: #f2f2f2;\"\u003eExpansion Slots\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e1x PCI, 1x PCIe x4\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd; background-color: #f2f2f2;\"\u003eFieldbus Communication\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePROFIBUS\/MP\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd; background-color: #f2f2f2;\"\u003eBuffered SRAM\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e2MB\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd; background-color: #f2f2f2;\"\u003eOperating System\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eWindows XP Professional MUI (EN, GE, FR, IT, SP, JP, CHN, KOR)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd; background-color: #f2f2f2;\"\u003ePower Supply\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eDC 24V\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd; background-color: #f2f2f2;\"\u003eProduct Phase\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eObsolete\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd; background-color: #f2f2f2;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e67.00 cm x 83.00 cm x 11.50 cm\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd; background-color: #f2f2f2;\"\u003eShipping Weight\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e17.00 kg\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd; background-color: #f2f2f2;\"\u003eCommodity Code\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e85371098\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd; background-color: #f2f2f2;\"\u003eExport Control Regulations (ECCN)\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eN\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eEthernet:\u003c\/strong\u003e 2x RJ45 ports for 10\/100\/1000 Mbit\/s network connectivity.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eUSB:\u003c\/strong\u003e 4x USB V2.0 ports, including one easily accessible front-side port for peripherals.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSerial:\u003c\/strong\u003e 1x COM1 port for serial communication.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePROFIBUS\/MP:\u003c\/strong\u003e Integrated interface for industrial fieldbus communication.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePower:\u003c\/strong\u003e DC 24V input terminal.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n    \u003cli\u003e\n\u003cstrong\u003eDe-energization:\u003c\/strong\u003e Ensure all power to the installation area is disconnected and secured before beginning installation.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Securely panel mount the SIMATIC Panel PC 677B into the designated enclosure cutout. Ensure proper ventilation space around the unit.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePower Connection:\u003c\/strong\u003e Connect a stable DC 24V power supply to the designated power terminals. Observe correct polarity to prevent damage.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Establish a reliable protective earth (PE) connection to the unit's grounding terminal to ensure electrical safety and minimize electromagnetic interference.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eInterface Connections:\u003c\/strong\u003e Connect Ethernet cables to the RJ45 ports, USB devices to the USB ports, and serial devices to the COM1 port as required by the application.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePROFIBUS\/MP Connection:\u003c\/strong\u003e Connect the PROFIBUS\/MP cable to the dedicated interface, ensuring proper termination if it is the end of a bus segment.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCable Routing:\u003c\/strong\u003e Route power and signal cables separately to minimize interference. Secure all cables to prevent strain and accidental disconnection.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eEnvironmental Conditions:\u003c\/strong\u003e Ensure the operating environment complies with the Panel PC's specified temperature, humidity, and vibration limits (if available in system documentation) to ensure reliable operation.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePower-Up:\u003c\/strong\u003e After all connections are verified, re-energize the system and observe for proper boot-up and functionality.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52715871502699,"sku":"6AV7872-0AF32-1AC0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6av7872-0af32-1ac0-mqkjq43ujsq_576a16a8-f253-41fe-9726-f3a985ca999a.jpg?v=1767073404","url":"https:\/\/www.plcprotech.com\/id\/products\/siemens-6av7872-0af32-1ac0-simatic-panel-pc-677b","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}