{"product_id":"siemens-6av7873-0bc20-0ac0-simatic-panel-pc-677b","title":"Siemens 6AV7873-0BC20-0AC0 SIMATIC Panel PC 677B","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\nThe Siemens \u003cstrong\u003e6AV7873-0BC20-0AC0\u003c\/strong\u003e is a SIMATIC Panel PC 677B, designed for industrial visualization and control tasks. This unit integrates a 15-inch key-operated display with a resolution of 1024x768 pixels, featuring a front-side USB interface for convenient access. It is equipped with a Core 2 Duo T5500 processor running at 1.66 GHz, 1 GB DDR2 RAM, and a 160 GB SATA HDD. Connectivity options include two 10\/100\/1000 Mbit\/s Ethernet ports, four USB V2.0 ports, and one serial (COM1) interface. The Panel PC supports PROFIBUS\/MP communication and operates with a 110\/230 V AC power supply, pre-installed with Windows XP Professional MUI (Multi-User Interface) in multiple languages.\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIntegrated 15-inch Key Display with 1024x768 resolution\u003c\/li\u003e\n\u003cli\u003eCore 2 Duo T5500 Processor (1.66 GHz, 2 MB SLC)\u003c\/li\u003e\n\u003cli\u003e1 GB DDR2 RAM\u003c\/li\u003e\n\u003cli\u003e160 GB SATA HDD 3.5\"\u003c\/li\u003e\n\u003cli\u003eDual 10\/100\/1000 Mbit\/s Ethernet Interfaces\u003c\/li\u003e\n\u003cli\u003eFour USB V2.0 Ports (including one front-side)\u003c\/li\u003e\n\u003cli\u003eOne Serial (COM1) Interface\u003c\/li\u003e\n\u003cli\u003ePROFIBUS\/MP Communication Support with 2 MB BUFF. SRAM\u003c\/li\u003e\n\u003cli\u003ePre-installed Windows XP Professional MUI (de, en, fr, es, it, ja, zh, ko)\u003c\/li\u003e\n\u003cli\u003e110\/230 V AC Power Supply Unit with NAMUR compatibility\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\nThe Siemens SIMATIC Panel PC 677B is suitable for a range of industrial applications requiring robust, integrated computing and visualization, including:\n\u003cul\u003e\n\u003cli\u003eMachine-level HMI and control\u003c\/li\u003e\n\u003cli\u003eProcess visualization and data acquisition\u003c\/li\u003e\n\u003cli\u003eProduction line monitoring and management\u003c\/li\u003e\n\u003cli\u003eIndustrial data processing and communication gateways\u003c\/li\u003e\n\u003cli\u003eDistributed control systems (DCS) and supervisory control and data acquisition (SCADA) interfaces\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n\u003ctable border=\"1\" style=\"width:100%; border-collapse: collapse;\"\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eBrand\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSiemens\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSiemens\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eRange\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSimatic Panel PC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSubrange\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePC677B\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eProduct Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePanel PC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePLM Product Phase\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eObsolete\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eProcessor\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCore 2 Duo T5500, 1.66 GHz, 2 MB SLC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eRAM\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e1 GB DDR2 RAM\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eStorage\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e160 GB SATA HDD 3.5\" (without optical drive)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eDisplay Size\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e15 inches\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eResolution\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e1024 x 768\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eEthernet Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e2x 10\/100\/1000 Mbit\/s\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eUSB Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e4x USB V2.0 (1x front-side)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSerial Port\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e1x COM1\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCommunication Interface\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePROFIBUS\/MP (2 MB BUFF. SRAM)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eOperating System\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eWindows XP Professional MUI (de, en, fr, es, it, ja, zh, ko)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePower Supply\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e110\/230 V AC (with NAMUR)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePower Cable\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eEurope\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e67.00 x 83.00 x 11.50 cm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e17.00 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e85371098\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eExport Control Regulations (ECCN)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eN\u003c\/td\u003e\n    \u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n\u003ctable border=\"1\" style=\"width:100%; border-collapse: collapse;\"\u003e\n    \u003cthead\u003e\n        \u003ctr\u003e\n            \u003cth style=\"padding: 8px; border: 1px solid #ddd; text-align: left;\"\u003eInterface Type\u003c\/th\u003e\n            \u003cth style=\"padding: 8px; border: 1px solid #ddd; text-align: left;\"\u003eQuantity \/ Specification\u003c\/th\u003e\n        \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eEthernet\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e2x 10\/100\/1000 Mbit\/s\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eUSB\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e4x USB V2.0 (including 1x front-side)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSerial\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e1x COM1\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePROFIBUS\/MP\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eIntegrated\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\nProper installation ensures reliable operation and longevity of the Panel PC.\n\u003col\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePower De-energization:\u003c\/strong\u003e Before commencing any installation or wiring, ensure that all power to the system and the Panel PC is completely de-energized and locked out according to standard safety procedures.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Mount the Panel PC securely into a control cabinet or panel cutout. Ensure adequate space for ventilation around the unit to prevent overheating.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePower Connection:\u003c\/strong\u003e Connect the 110\/230 V AC power supply cable to the designated power input terminals. Verify correct voltage and polarity before applying power.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Establish a robust protective earth (PE) connection to the Panel PC chassis. Proper grounding is critical for electrical safety and electromagnetic compatibility (EMC).\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eEthernet Connections:\u003c\/strong\u003e Connect industrial Ethernet cables to the 10\/100\/1000 Mbit\/s Ethernet ports for network communication. Use shielded cables in noisy industrial environments.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eUSB and Serial Connections:\u003c\/strong\u003e Connect peripheral devices or external modules to the USB V2.0 ports or the COM1 serial port as required by the application.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePROFIBUS\/MP Connection:\u003c\/strong\u003e If utilizing PROFIBUS\/MP, connect the appropriate bus cable to the designated interface. Ensure correct termination and segment configuration.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eEnvironmental Considerations:\u003c\/strong\u003e Ensure the operating environment adheres to the specified temperature, humidity, and vibration limits for industrial Panel PCs. Protect the unit from direct sunlight, excessive dust, and moisture.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCable Routing:\u003c\/strong\u003e Route power, communication, and I\/O cables separately where possible to minimize electromagnetic interference. Secure all cables to prevent strain and accidental disconnection.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52715860033899,"sku":"6AV7873-0BC20-0AC0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6av7873-0bc20-0ac0-m3scelfxvww_ddd46b65-7b4d-4e32-b20b-e98772dc5591.jpg?v=1767072989","url":"https:\/\/www.plcprotech.com\/id\/products\/siemens-6av7873-0bc20-0ac0-simatic-panel-pc-677b","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}