{"product_id":"siemens-6av7884-1ah10-6da0-simatic-panel-pc-hmi-ipc-477c-industrial-pc","title":"Siemens 6AV7884-1AH10-6DA0 SIMATIC Panel PC HMI IPC 477C Industrial PC","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\nThe Siemens \u003cstrong\u003e6AV7884-1AH10-6DA0\u003c\/strong\u003e is a SIMATIC HMI IPC 477C Industrial PC, designed for robust operation in industrial environments. This unit features a \u003cstrong\u003e12-inch key display\u003c\/strong\u003e with an \u003cstrong\u003e800 x 600 resolution\u003c\/strong\u003e, making it suitable for human-machine interface applications. It is powered by a \u003cstrong\u003eCore 2 Duo 1.2 GHz processor\u003c\/strong\u003e and includes \u003cstrong\u003e1 GB of DDR3 RAM\u003c\/strong\u003e. For data storage, it is equipped with a \u003cstrong\u003e50 GB SATA Solid-State Drive (SSD)\u003c\/strong\u003e, specified for high endurance, and comes with \u003cstrong\u003eWindows XP Professional Multi-Language\u003c\/strong\u003e pre-installed. Communication capabilities include \u003cstrong\u003ePROFINET (IE)\u003c\/strong\u003e via two 1 GBIT interfaces and \u003cstrong\u003ePROFIBUS DP 12\u003c\/strong\u003e. The unit also provides flexible connectivity with four USB ports on the back and one USB port on the front.\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSIMATIC HMI IPC 477C series Industrial PC\u003c\/li\u003e\n\u003cli\u003e12-inch key display with 800 x 600 resolution\u003c\/li\u003e\n\u003cli\u003eCore 2 Duo 1.2 GHz processor\u003c\/li\u003e\n\u003cli\u003e1 GB DDR3 RAM\u003c\/li\u003e\n\u003cli\u003e50 GB SATA Solid-State Drive (SSD) for high endurance\u003c\/li\u003e\n\u003cli\u003eWindows XP Professional Multi-Language pre-installed\u003c\/li\u003e\n\u003cli\u003eIntegrated PROFINET (IE) with 2x 1 GBIT interfaces\u003c\/li\u003e\n\u003cli\u003eIntegrated PROFIBUS DP 12 interface\u003c\/li\u003e\n\u003cli\u003eFive USB ports (4 rear, 1 front)\u003c\/li\u003e\n\u003cli\u003ePhase-Out product status\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\nThe Siemens 6AV7884-1AH10-6DA0 is typically deployed in industrial automation settings requiring a reliable human-machine interface and local processing capabilities. Common applications include:\n\u003cul\u003e\n\u003cli\u003eMachine operation and control panels\u003c\/li\u003e\n\u003cli\u003eProcess visualization and monitoring systems\u003c\/li\u003e\n\u003cli\u003eData acquisition and local data processing\u003c\/li\u003e\n\u003cli\u003eDistributed control system (DCS) operator stations\u003c\/li\u003e\n\u003cli\u003eManufacturing execution systems (MES) terminals\u003c\/li\u003e\n\u003cli\u003eBuilding automation control interfaces\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n\u003ctable border=\"1\" style=\"width:100%; border-collapse: collapse;\"\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eBrand\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSiemens\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSiemens\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eRange\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSimatic Panel PC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSubrange\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eHMI\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eType of Product\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eIndustrial PC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eModel\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e6AV7884-1AH10-6DA0\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eDisplay Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eKey Display\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eDisplay Size\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e12 inches\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eResolution\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e800 x 600\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eProcessor\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCore 2 Duo 1.2 GHz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eRAM\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e1 GB DDR3\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eStorage\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e50 GB Solid-State Drive (SATA, High Endurance)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eOperating System\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eWindows XP Professional Multi-Language (pre-installed)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eUSB Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e4 (back), 1 (front)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCommunication Interfaces\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePROFINET (IE) 2x 1 GBIT, PROFIBUS DP 12\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCF Slot\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e2nd CF slot not equipped\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePLM Product Phase\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePhase-Out\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e64.00 x 64.00 x 42.00 cm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e15.00 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e85371098\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eExport Control Regulations (ECCN)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eN\u003c\/td\u003e\n    \u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n\u003ctable border=\"1\" style=\"width:100%; border-collapse: collapse;\"\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eInterface Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eQuantity \/ Description\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eUSB\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e4 (rear panel), 1 (front panel)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePROFINET (IE)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e2x 1 GBIT Ethernet ports\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePROFIBUS DP\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e1 (12 Mbit\/s)\u003c\/td\u003e\n    \u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSafety First:\u003c\/strong\u003e Ensure all power to the installation area is de-energized and locked out before beginning any work.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Securely mount the Panel PC into a prepared panel cutout or enclosure, ensuring proper ventilation clearances as required by the system design.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Connect the protective earth (PE) terminal of the Panel PC to the central grounding point of the control cabinet or machine using a low-impedance connection. Proper grounding is critical for EMC compliance and operational safety.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePower Connection:\u003c\/strong\u003e Connect the Panel PC to a stable and filtered industrial power supply. Verify correct voltage and polarity before applying power.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCommunication Cabling:\u003c\/strong\u003e Connect PROFINET and PROFIBUS DP cables to their respective ports. Use shielded cables for industrial communication and ensure proper cable routing to avoid interference.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eUSB Devices:\u003c\/strong\u003e Connect any required USB peripherals (e.g., keyboard, mouse, external storage) to the available USB ports.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eEnvironmental Considerations:\u003c\/strong\u003e Ensure the operating environment meets the specified temperature, humidity, and vibration limits for industrial PCs to ensure long-term reliability.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePower On:\u003c\/strong\u003e After all connections are verified, re-energize the power supply and observe the Panel PC's startup sequence.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716358402411,"sku":"6AV7884-1AH10-6DA0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6av7884-1ah10-6da0-dtihxtnijxm_4aab9b5e-dde4-4146-a84c-11ab6e431baf.jpg?v=1767081213","url":"https:\/\/www.plcprotech.com\/id\/products\/siemens-6av7884-1ah10-6da0-simatic-panel-pc-hmi-ipc-477c-industrial-pc","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}