{"product_id":"siemens-6av7893-1ag32-0aa0-simatic-ipc677c-panel-pc","title":"Siemens 6AV7893-1AG32-0AA0 SIMATIC IPC677C Panel PC","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Siemens 6AV7893-1AG32-0AA0 is a SIMATIC IPC677C Panel PC, an integrated human-machine interface (HMI) solution for demanding industrial environments. This unit features a \u003cstrong\u003e15-inch display\u003c\/strong\u003e with keypad input and is powered by an \u003cstrong\u003eIntel Core i7-610E processor\u003c\/strong\u003e. It is configured with \u003cstrong\u003e4 GB of DDR3 RAM\u003c\/strong\u003e and a redundant \u003cstrong\u003eRAID1 storage system\u003c\/strong\u003e using two 320 GB SATA hard drives. Integrated monitoring for watchdog, temperature, and fan status ensures high operational reliability. Connectivity is provided through dual Gigabit Ethernet ports, four USB 2.0 ports, and a serial interface, all powered by a \u003cstrong\u003e24 V DC\u003c\/strong\u003e supply.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 0;\"\u003e\n    \u003cli\u003e15-inch display with 1024 x 768 resolution and keypad\u003c\/li\u003e\n    \u003cli\u003eIntel Core i7-610E dual-core processor (2.53 GHz)\u003c\/li\u003e\n    \u003cli\u003eOnboard RAID controller with RAID1 disk mirroring for data redundancy\u003c\/li\u003e\n    \u003cli\u003eIntegrated system monitoring for watchdog, temperature, and fan\u003c\/li\u003e\n    \u003cli\u003eDual 10\/100\/1000 Mbit\/s Ethernet ports for network connectivity\u003c\/li\u003e\n    \u003cli\u003eFour rear-mounted USB 2.0 ports and one serial (COM1) port\u003c\/li\u003e\n    \u003cli\u003eTwo free PCI slots for hardware expansion\u003c\/li\u003e\n    \u003cli\u003eRobust design for industrial applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 0;\"\u003e\n    \u003cli\u003eProcess visualization and control (SCADA)\u003c\/li\u003e\n    \u003cli\u003eMachine-level operator control and monitoring\u003c\/li\u003e\n    \u003cli\u003eData acquisition and logging systems\u003c\/li\u003e\n    \u003cli\u003eFactory automation and plant floor management\u003c\/li\u003e\n    \u003cli\u003eIndustrial IT gateway applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n    \u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #e2e8f0;\"\u003e\n        \u003cthead\u003e\n            \u003ctr\u003e\n                \u003cth style=\"background-color: #f7fafc; padding: 12px; border: 1px solid #e2e8f0; text-align: left; color: #2d3748;\"\u003eSpecification\u003c\/th\u003e\n                \u003cth style=\"background-color: #f7fafc; padding: 12px; border: 1px solid #e2e8f0; text-align: left; color: #2d3748;\"\u003eValue\u003c\/th\u003e\n            \u003c\/tr\u003e\n        \u003c\/thead\u003e\n        \u003ctbody\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eProduct Type\u003c\/td\u003e\n                \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003ePanel PC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eSeries\u003c\/td\u003e\n                \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eSIMATIC HMI IPC677C\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eDisplay\u003c\/td\u003e\n                \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003e15-inch Keypad Interface, 1024 x 768 Resolution\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eProcessor\u003c\/td\u003e\n                \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eIntel Core i7-610E (2C\/4T, 2.53 GHz, TB, HT, VT, 4 MB Cache)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eMemory\u003c\/td\u003e\n                \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003e4 GB DDR3 1066 DIMM\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eStorage\u003c\/td\u003e\n                \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eRAID1 Configuration (Mirror Disks), 2x 320 GB SATA (2.5\")\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eRAID Controller\u003c\/td\u003e\n                \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eOnboard\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eOptical Drive\u003c\/td\u003e\n                \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eNot included\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eExpansion Slots\u003c\/td\u003e\n                \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003e2x PCI (Free)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eEthernet Ports\u003c\/td\u003e\n                \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003e2x 10\/100\/1000 Mbit\/s\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eUSB Ports\u003c\/td\u003e\n                \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003e4x USB V2.0 (Rear)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eFront USB Interface\u003c\/td\u003e\n                \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eNot included\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eSerial Port\u003c\/td\u003e\n                \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003e1x Serial (COM1)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eSystem Monitoring\u003c\/td\u003e\n                \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eWatchdog, Temperature, and Fan Monitoring\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003ePower Supply\u003c\/td\u003e\n                \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003e24 V DC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eOperating System\u003c\/td\u003e\n                \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eNot included\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eExpansion Software\u003c\/td\u003e\n                \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eNot included\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eProduct Lifecycle Status\u003c\/td\u003e\n                \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003ePhase-Out\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eShipping Weight\u003c\/td\u003e\n                \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003e17.35 kg\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eCommodity Code\u003c\/td\u003e\n                \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003e85371098\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eManufacturer\u003c\/td\u003e\n                \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eSiemens\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eCountry of Origin\u003c\/td\u003e\n                \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003eGermany (Estimated)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n                \u003ctd style=\"padding: 12px; border: 1px solid #e2e8f0;\"\u003e55 x 45 x 25 cm\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/tbody\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-top: 24px; margin-bottom: 16px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 16px; margin-bottom: 20px;\"\u003e\n    \u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e Electrical Hazard. Disconnect all power sources and follow Lockout\/Tagout (LOTO) procedures before installation or servicing. Installation must be performed by qualified personnel familiar with industrial control panel standards.\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0;\"\u003e\n    \u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n        \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n        \u003cdiv\u003e\n\u003cstrong\u003ePanel Mounting:\u003c\/strong\u003e Ensure the control cabinet cutout dimensions match the IPC677C specifications. Secure the unit into the panel using all provided mounting clamps, tightening them evenly to the manufacturer's recommended torque to ensure a proper seal (IP rating).\u003c\/div\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n        \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n        \u003cdiv\u003e\n\u003cstrong\u003eProtective Earth (PE) Connection:\u003c\/strong\u003e Connect the chassis PE terminal to the main protective earth busbar of the cabinet using a low-impedance conductor. This is critical for operator safety and electromagnetic compatibility (EMC).\u003c\/div\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n        \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n        \u003cdiv\u003e\n\u003cstrong\u003ePower Supply Wiring:\u003c\/strong\u003e Connect a stable, filtered 24 V DC power source to the designated power supply terminals. Use appropriately sized wiring for the current draw and ensure correct polarity. It is recommended to use a dedicated circuit breaker for the Panel PC.\u003c\/div\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n        \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n        \u003cdiv\u003e\n\u003cstrong\u003eI\/O and Network Cabling:\u003c\/strong\u003e Route all communication cables (Ethernet, USB, Serial) away from high-voltage power lines to minimize electrical noise. Use shielded cables for all data connections where specified, and ensure shields are properly terminated at one end to the cabinet ground.\u003c\/div\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n        \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e5\u003c\/span\u003e\n        \u003cdiv\u003e\n\u003cstrong\u003eVentilation and Clearance:\u003c\/strong\u003e Maintain adequate clearance around the rear of the unit as specified by the manufacturer to ensure proper airflow for cooling. Do not block ventilation openings. Verify cabinet cooling is sufficient for the total heat load.\u003c\/div\u003e\n    \u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52715866259819,"sku":"6AV7893-1AG32-0AA0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6av7893-1ag32-0aa0-1huhu2tvb0q_c7916cbf-794e-4414-a683-b25494f733fb.jpg?v=1767073219","url":"https:\/\/www.plcprotech.com\/id\/products\/siemens-6av7893-1ag32-0aa0-simatic-ipc677c-panel-pc","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}