{"product_id":"siemens-6es7155-6ar00-0an0-simatic-et-200sp-profinet-interface-module","title":"Siemens 6ES7155-6AR00-0AN0 SIMATIC ET 200SP PROFINET Interface Module","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748;\"\u003eThe Siemens 6ES7155-6AR00-0AN0 is a compact PROFINET interface module for the SIMATIC ET 200SP distributed I\/O system. It is engineered for cost-effective implementation in simple automation tasks and smaller-scale applications, providing a reliable entry point for decentralized I\/O. This module supports a configuration of up to \u003cstrong\u003e12 peripheral modules\u003c\/strong\u003e, accommodating a maximum of \u003cstrong\u003e192 I\/O signals\u003c\/strong\u003e. It manages a process image data capacity of \u003cstrong\u003e32 bytes for inputs\u003c\/strong\u003e and \u003cstrong\u003e32 bytes for outputs\u003c\/strong\u003e, making it suitable for focused control applications requiring dependable PROFINET connectivity.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px;\"\u003e\n  \u003cli\u003eIntegrates with the SIMATIC ET 200SP distributed I\/O system.\u003c\/li\u003e\n  \u003cli\u003eSupports connection of up to 12 peripheral I\/O modules.\u003c\/li\u003e\n  \u003cli\u003eManages a maximum of 192 digital or analog I\/O signals.\u003c\/li\u003e\n  \u003cli\u003eFeatures an integrated 2-port switch with two RJ45 sockets.\u003c\/li\u003e\n  \u003cli\u003eEnables linear network topology without external switches.\u003c\/li\u003e\n  \u003cli\u003eIncludes a built-in server module.\u003c\/li\u003e\n  \u003cli\u003eMounts directly onto a standard DIN rail for easy installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px;\"\u003e\n  \u003cli\u003eDecentralized peripheral systems\u003c\/li\u003e\n  \u003cli\u003eSmall-scale machine control\u003c\/li\u003e\n  \u003cli\u003eFactory automation\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels\u003c\/li\u003e\n  \u003cli\u003eProcess data acquisition\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; color: #2d3748;\"\u003e\n  \u003ctr style=\"border-bottom: 1px solid #cbd5e0;\"\u003e\n    \u003ctd style=\"padding: 12px 15px; background-color: #f7fafc; font-weight: 600; text-align: left;\"\u003eProperty\u003c\/td\u003e\n    \u003ctd style=\"padding: 12px 15px; text-align: left;\"\u003eValue\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #cbd5e0;\"\u003e\n    \u003ctd style=\"padding: 12px 15px; background-color: #f7fafc; font-weight: 600; text-align: left;\"\u003eManufacturer\u003c\/td\u003e\n    \u003ctd style=\"padding: 12px 15px; text-align: left;\"\u003eSiemens\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #cbd5e0;\"\u003e\n    \u003ctd style=\"padding: 12px 15px; background-color: #f7fafc; font-weight: 600; text-align: left;\"\u003eModel Number\u003c\/td\u003e\n    \u003ctd style=\"padding: 12px 15px; text-align: left;\"\u003e6ES7155-6AR00-0AN0\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #cbd5e0;\"\u003e\n    \u003ctd style=\"padding: 12px 15px; background-color: #f7fafc; font-weight: 600; text-align: left;\"\u003eProduct Family\u003c\/td\u003e\n    \u003ctd style=\"padding: 12px 15px; text-align: left;\"\u003eSIMATIC ET 200SP\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #cbd5e0;\"\u003e\n    \u003ctd style=\"padding: 12px 15px; background-color: #f7fafc; font-weight: 600; text-align: left;\"\u003eModule Type\u003c\/td\u003e\n    \u003ctd style=\"padding: 12px 15px; text-align: left;\"\u003ePROFINET Interface Module\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #cbd5e0;\"\u003e\n    \u003ctd style=\"padding: 12px 15px; background-color: #f7fafc; font-weight: 600; text-align: left;\"\u003eCommunication Protocol\u003c\/td\u003e\n    \u003ctd style=\"padding: 12px 15px; text-align: left;\"\u003ePROFINET\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #cbd5e0;\"\u003e\n    \u003ctd style=\"padding: 12px 15px; background-color: #f7fafc; font-weight: 600; text-align: left;\"\u003eMax. Peripheral Modules\u003c\/td\u003e\n    \u003ctd style=\"padding: 12px 15px; text-align: left;\"\u003e12\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #cbd5e0;\"\u003e\n    \u003ctd style=\"padding: 12px 15px; background-color: #f7fafc; font-weight: 600; text-align: left;\"\u003eMax. I\/O Signals\u003c\/td\u003e\n    \u003ctd style=\"padding: 12px 15px; text-align: left;\"\u003e192\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #cbd5e0;\"\u003e\n    \u003ctd style=\"padding: 12px 15px; background-color: #f7fafc; font-weight: 600; text-align: left;\"\u003eProcess Image Size (Input)\u003c\/td\u003e\n    \u003ctd style=\"padding: 12px 15px; text-align: left;\"\u003e32 bytes\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #cbd5e0;\"\u003e\n    \u003ctd style=\"padding: 12px 15px; background-color: #f7fafc; font-weight: 600; text-align: left;\"\u003eProcess Image Size (Output)\u003c\/td\u003e\n    \u003ctd style=\"padding: 12px 15px; text-align: left;\"\u003e32 bytes\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #cbd5e0;\"\u003e\n    \u003ctd style=\"padding: 12px 15px; background-color: #f7fafc; font-weight: 600; text-align: left;\"\u003eNetwork Interface\u003c\/td\u003e\n    \u003ctd style=\"padding: 12px 15px; text-align: left;\"\u003e2 x RJ45 (Integrated 2-port switch)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #cbd5e0;\"\u003e\n    \u003ctd style=\"padding: 12px 15px; background-color: #f7fafc; font-weight: 600; text-align: left;\"\u003eMounting\u003c\/td\u003e\n    \u003ctd style=\"padding: 12px 15px; text-align: left;\"\u003eStandard DIN Rail\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #cbd5e0;\"\u003e\n    \u003ctd style=\"padding: 12px 15px; background-color: #f7fafc; font-weight: 600; text-align: left;\"\u003eShipping Weight\u003c\/td\u003e\n    \u003ctd style=\"padding: 12px 15px; text-align: left;\"\u003e0.95 kg\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #cbd5e0;\"\u003e\n    \u003ctd style=\"padding: 12px 15px; background-color: #f7fafc; font-weight: 600; text-align: left;\"\u003ePackage Dimensions (Source)\u003c\/td\u003e\n    \u003ctd style=\"padding: 12px 15px; text-align: left;\"\u003e2.5 cm x 5.1 cm x 83.8 cm\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #cbd5e0;\"\u003e\n    \u003ctd style=\"padding: 12px 15px; background-color: #f7fafc; font-weight: 600; text-align: left;\"\u003eCountry of Origin\u003c\/td\u003e\n    \u003ctd style=\"padding: 12px 15px; text-align: left;\"\u003eGermany\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"border-bottom: 1px solid #cbd5e0;\"\u003e\n    \u003ctd style=\"padding: 12px 15px; background-color: #f7fafc; font-weight: 600; text-align: left;\"\u003eHS Code\u003c\/td\u003e\n    \u003ctd style=\"padding: 12px 15px; text-align: left;\"\u003e8537101190\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px; margin-top: 24px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"padding: 16px; background-color: #fff5f5; border-left: 4px solid #c53030; margin-bottom: 20px;\"\u003e\n  \u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e Disconnect all power sources and implement Lockout\/Tagout (LOTO) procedures before installation or maintenance. Failure to de-energize the system can result in severe electrical shock, equipment damage, or personal injury.\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0; color: #2d3748;\"\u003e\n  \u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n    Securely mount the module onto a standard 35mm DIN rail inside the control cabinet, ensuring proper orientation and adequate clearance for ventilation and wiring.\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n    Install the required ET 200SP peripheral modules onto the backplane, starting from the slot adjacent to the interface module. Ensure each module is fully seated.\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n    Connect the incoming and outgoing PROFINET cables to the RJ45 ports. Use shielded, industrial-grade Ethernet cables and ensure proper shield termination to minimize electromagnetic interference.\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n    Connect the 24V DC power supply to the designated terminals on the power bus module. Verify correct polarity before energizing the system.\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e5\u003c\/span\u003e\n    After completing all connections, remove LOTO devices and apply power. Verify module status indicators for correct operation and network communication.\n  \u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52695212523883,"sku":"6ES7155-6AR00-0AN0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/siemens-6es7155-6ar00-0an0-interface-module-bdvho0n35bk_174f869e-20f5-47b2-8267-1ec9e1447988.jpg?v=1766130870","url":"https:\/\/www.plcprotech.com\/id\/products\/siemens-6es7155-6ar00-0an0-simatic-et-200sp-profinet-interface-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}