{"product_id":"siemens-6es7193-6bp00-0da0-simatic-et-200sp-base-unit","title":"Siemens 6ES7193-6BP00-0DA0 SIMATIC ET 200SP Base Unit","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px; margin-top: 20px; margin-bottom: 16px;\"\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748;\"\u003eThis is the Siemens 6ES7193-6BP00-0DA0, a Type A0 BaseUnit for the SIMATIC ET 200SP distributed I\/O system. It serves as the mounting and termination base for ET 200SP I\/O modules, providing \u003cstrong\u003e16 push-in terminals\u003c\/strong\u003e for rapid, tool-free connection of field wiring. With a compact width of only \u003cstrong\u003e15 mm\u003c\/strong\u003e, this BaseUnit is designed for high-density control cabinet layouts. It supports a continuous potential group, allowing power to be passed directly to subsequent modules. The design includes robust electrical isolation tested at \u003cstrong\u003e707 V DC\u003c\/strong\u003e between the backplane bus and the power supply, enhancing system safety and signal integrity.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px; margin-top: 30px; margin-bottom: 16px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: none; padding-left: 0; color: #2d3748;\"\u003e\n\u003cli\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 0; color: #2b6cb0; font-weight: bold;\"\u003e■\u003c\/span\u003eDesigned for the Siemens SIMATIC ET 200SP distributed I\/O family.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 0; color: #2b6cb0; font-weight: bold;\"\u003e■\u003c\/span\u003eFeatures 16 push-in terminals for efficient, tool-free wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 0; color: #2b6cb0; font-weight: bold;\"\u003e■\u003c\/span\u003eSpace-saving 15 mm width for high-density panel configurations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 0; color: #2b6cb0; font-weight: bold;\"\u003e■\u003c\/span\u003eEnables a continuous potential group for simplified power distribution.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 0; color: #2b6cb0; font-weight: bold;\"\u003e■\u003c\/span\u003eRequires external fusing for the 24 V DC power supply lines.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px; margin-top: 30px; margin-bottom: 16px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: none; padding-left: 0; color: #2d3748;\"\u003e\n\u003cli\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 0; color: #2b6cb0; font-weight: bold;\"\u003e■\u003c\/span\u003eFactory and Process Automation\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 0; color: #2b6cb0; font-weight: bold;\"\u003e■\u003c\/span\u003eDistributed Control Systems (DCS)\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 0; color: #2b6cb0; font-weight: bold;\"\u003e■\u003c\/span\u003eMachine Building and OEM Equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 0; color: #2b6cb0; font-weight: bold;\"\u003e■\u003c\/span\u003eMaterial Handling and Conveyor Systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px; margin-top: 30px; margin-bottom: 16px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; color: #2d3748;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"border: 1px solid #ccc; padding: 10px; text-align: left; background-color: #f9f9f9;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #ccc; padding: 10px; text-align: left; background-color: #f9f9f9;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px; text-align: left;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px; text-align: left;\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px; text-align: left;\"\u003ePart Number\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px; text-align: left;\"\u003e6ES7193-6BP00-0DA0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px; text-align: left;\"\u003eProduct Family\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px; text-align: left;\"\u003eSIMATIC ET 200SP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px; text-align: left;\"\u003eModule Type\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px; text-align: left;\"\u003eBaseUnit Type A0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px; text-align: left;\"\u003eTerminal Count\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px; text-align: left;\"\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px; text-align: left;\"\u003eTerminal Technology\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px; text-align: left;\"\u003ePush-in terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px; text-align: left;\"\u003eIsolation Test Voltage\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px; text-align: left;\"\u003e707 V DC (between backplane bus and power supply)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px; text-align: left;\"\u003eWidth\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px; text-align: left;\"\u003e15 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px; text-align: left;\"\u003eShipping Weight\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px; text-align: left;\"\u003e0.95 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px; text-align: left;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px; text-align: left;\"\u003e2.5 cm x 5.1 cm x 83.8 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px; text-align: left;\"\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px; text-align: left;\"\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px; text-align: left;\"\u003eHS Code\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px; text-align: left;\"\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px; margin-top: 30px; margin-bottom: 16px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 5px solid #c53030; padding: 15px; margin-bottom: 20px;\"\u003e\n\u003cp style=\"color: #c53030; font-weight: bold; margin: 0;\"\u003eCRITICAL WARNING: RISK OF ELECTRIC SHOCK\u003c\/p\u003e\n\u003cp style=\"color: #2d3748; margin-top: 8px; margin-bottom: 0;\"\u003eDisconnect and lock out all power sources to the control panel before installation, removal, or wiring of this module. Failure to de-energize the system can result in severe injury or death.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003col style=\"list-style-type: none; padding-left: 0; counter-reset: step-counter;\"\u003e\n\u003cli style=\"color: #2d3748; margin-bottom: 15px; padding-left: 45px; position: relative; min-height: 30px;\"\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 0; display: flex; align-items: center; justify-content: center; width: 30px; height: 30px; background-color: #2b6cb0; color: white; border-radius: 50%; font-weight: bold; counter-increment: step-counter; content: counter(step-counter);\"\u003e\u003c\/span\u003e\nVerify that the mounting location is clean, dry, and free from excessive vibration. Ensure a reliable, low-impedance protective earth (PE) connection is available at the DIN rail.\n\u003c\/li\u003e\n\u003cli style=\"color: #2d3748; margin-bottom: 15px; padding-left: 45px; position: relative; min-height: 30px;\"\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 0; display: flex; align-items: center; justify-content: center; width: 30px; height: 30px; background-color: #2b6cb0; color: white; border-radius: 50%; font-weight: bold; counter-increment: step-counter; content: counter(step-counter);\"\u003e\u003c\/span\u003e\nMount the BaseUnit onto a standard 35 mm DIN rail. Hook the top edge onto the rail and press down firmly until the bottom latch clicks securely into place.\n\u003c\/li\u003e\n\u003cli style=\"color: #2d3748; margin-bottom: 15px; padding-left: 45px; position: relative; min-height: 30px;\"\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 0; display: flex; align-items: center; justify-content: center; width: 30px; height: 30px; background-color: #2b6cb0; color: white; border-radius: 50%; font-weight: bold; counter-increment: step-counter; content: counter(step-counter);\"\u003e\u003c\/span\u003e\nSlide the BaseUnit adjacent to the previous module in the ET 200SP station, ensuring the side connectors are properly aligned and engaged to establish the backplane bus connection.\n\u003c\/li\u003e\n\u003cli style=\"color: #2d3748; margin-bottom: 15px; padding-left: 45px; position: relative; min-height: 30px;\"\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 0; display: flex; align-items: center; justify-content: center; width: 30px; height: 30px; background-color: #2b6cb0; color: white; border-radius: 50%; font-weight: bold; counter-increment: step-counter; content: counter(step-counter);\"\u003e\u003c\/span\u003e\nInsert the corresponding ET 200SP I\/O module onto the BaseUnit until it is fully seated.\n\u003c\/li\u003e\n\u003cli style=\"color: #2d3748; margin-bottom: 15px; padding-left: 45px; position: relative; min-height: 30px;\"\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 0; display: flex; align-items: center; justify-content: center; width: 30px; height: 30px; background-color: #2b6cb0; color: white; border-radius: 50%; font-weight: bold; counter-increment: step-counter; content: counter(step-counter);\"\u003e\u003c\/span\u003e\nTerminate field device wiring. Strip wire insulation to the correct length and insert the conductor fully into the appropriate push-in terminal until it stops. Verify a secure mechanical connection.\n\u003c\/li\u003e\n\u003cli style=\"color: #2d3748; margin-bottom: 15px; padding-left: 45px; position: relative; min-height: 30px;\"\u003e\n\u003cspan style=\"position: absolute; left: 0; top: 0; display: flex; align-items: center; justify-content: center; width: 30px; height: 30px; background-color: #2b6cb0; color: white; border-radius: 50%; font-weight: bold; counter-increment: step-counter; content: counter(step-counter);\"\u003e\u003c\/span\u003e\nAfter all connections are made and verified, close the control panel door, remove the lockout\/tagout device, and re-energize the system according to standard procedures.\n\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52695204561259,"sku":"6ES7193-6BP00-0DA0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/siemens-6es7193-6bp00-0da0-base-unit-quodglcumfi_2762675e-868e-4f5a-bab2-b3f6cd2404f6.jpg?v=1766130637","url":"https:\/\/www.plcprotech.com\/id\/products\/siemens-6es7193-6bp00-0da0-simatic-et-200sp-base-unit","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}