{"product_id":"siemens-6es7647-6bb10-0gb1-simatic-box-pc-627b-industrial-pc","title":"Siemens 6ES7647-6BB10-0GB1 SIMATIC Box PC 627B Industrial PC","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Siemens 6ES7647-6BB10-0GB1 is a SIMATIC Box PC 627B designed for robust performance in industrial environments. This unit is equipped with an Intel \u003cstrong\u003eCeleron M 440 processor\u003c\/strong\u003e running at \u003cstrong\u003e1.86 GHz\u003c\/strong\u003e, \u003cstrong\u003e512 MB of DDR2 RAM\u003c\/strong\u003e, and a \u003cstrong\u003eRAID1 storage configuration\u003c\/strong\u003e consisting of two 250 GB SATA hard drives for data redundancy. Connectivity is provided through dual Gigabit Ethernet ports, four high-current USB 2.0 ports, a serial COM port, and an integrated \u003cstrong\u003ePROFIBUS\/MPI interface\u003c\/strong\u003e. The system includes onboard monitoring for temperature and fan status, a watchdog timer for operational reliability, and is powered by a 110\/230V AC industrial power supply. This model is pre-installed with Windows XP Professional and includes SIMATIC PC DiagMonitor software. Please note that this product line is designated as obsolete by the manufacturer.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; color: #2d3748;\"\u003e\n\u003cli\u003ePowered by an Intel Celeron M 440 processor with a 533 MHz Front Side Bus.\u003c\/li\u003e\n\u003cli\u003eOnboard RAID1 controller with two 250 GB SATA hard drives for enhanced data protection.\u003c\/li\u003e\n\u003cli\u003eIntegrated PROFIBUS\/MPI interface for direct field-level communication.\u003c\/li\u003e\n\u003cli\u003eDual 10\/100\/1000 Mbit\/s Ethernet ports for network redundancy or segmentation.\u003c\/li\u003e\n\u003cli\u003eSystem health monitoring with integrated watchdog, temperature, and fan sensors.\u003c\/li\u003e\n\u003cli\u003eFour high-current USB 2.0 ports for connecting peripherals.\u003c\/li\u003e\n\u003cli\u003eTwo available PCI slots for hardware expansion.\u003c\/li\u003e\n\u003cli\u003eFront-accessible CompactFlash slot for removable storage or system backup.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; color: #2d3748;\"\u003e\n\u003cli\u003ePC-based automation and control systems\u003c\/li\u003e\n\u003cli\u003eHuman-Machine Interface (HMI) server applications\u003c\/li\u003e\n\u003cli\u003eData acquisition, logging, and gateway functions\u003c\/li\u003e\n\u003cli\u003eManufacturing Execution Systems (MES) interface\u003c\/li\u003e\n\u003cli\u003eIndustrial image processing and quality control\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; color: #2d3748;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"border: 1px solid #e2e8f0; padding: 8px; text-align: left; background-color: #f7fafc;\"\u003eCategory\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #e2e8f0; padding: 8px; text-align: left; background-color: #f7fafc;\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px; font-weight: bold;\"\u003eProcessor\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eIntel Celeron M 440 (1.86 GHz, 1 MB L2 Cache, 533 MHz FSB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px; font-weight: bold;\"\u003eMemory\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e512 MB DDR2 667 SODIMM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px; font-weight: bold;\"\u003eBuffered Memory\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e2 MB Buffered SRAM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px; font-weight: bold;\"\u003eStorage\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eRAID1 Configuration: 2x 250 GB SATA (2.5\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px; font-weight: bold;\"\u003eGraphics\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eOnboard, 128 MB Shared Memory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px; font-weight: bold;\"\u003eInterfaces\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e2x 10\/100\/1000 Mbit\/s Ethernet (RJ45)\u003cbr\u003e4x USB V2.0 (High Current)\u003cbr\u003e1x Serial (COM1)\u003cbr\u003e1x PROFIBUS\/MPI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px; font-weight: bold;\"\u003eExpansion Slots\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e2x PCI (free)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px; font-weight: bold;\"\u003eRemovable Media\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e1x CompactFlash Drive Slot (front-side, without CF card)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px; font-weight: bold;\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eAC 110\/230V Industrial Power Supply with NAMUR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px; font-weight: bold;\"\u003eSystem Monitoring\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eWatchdog, Temperature Monitoring, Fan Monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px; font-weight: bold;\"\u003eOperating System\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eWindows XP Professional SP2 (Multi-language)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px; font-weight: bold;\"\u003eIncluded Software\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eSIMATIC PC DiagMonitor Software V3.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px; font-weight: bold;\"\u003eProduct Lifecycle Status\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eObsolete\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003eGermany (Estimate)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px; font-weight: bold;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e120.5 x 50.5 x 10.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px; font-weight: bold;\"\u003eShipping Weight\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e7.00 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px; font-weight: bold;\"\u003eCommodity Code\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e84715000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px; font-weight: bold;\"\u003eECCN\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #e2e8f0; padding: 8px;\"\u003e5D992\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px; margin-top: 24px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"padding: 12px; background-color: #fff5f5; border-left: 4px solid #c53030; margin-bottom: 16px;\"\u003e\n\u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e Electrical Hazard. Disconnect all power sources before installation or maintenance. This equipment must be installed and serviced by qualified personnel only, in accordance with all applicable safety standards and regulations. Failure to comply can result in severe injury or death.\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0; color: #2d3748;\"\u003e\n\u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\nEnsure the mounting location provides adequate ventilation and is free from excessive vibration, moisture, and corrosive contaminants. Maintain specified ambient operating temperature ranges.\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\nSecurely mount the Box PC chassis to a stable panel or surface using all provided mounting points. Verify the unit is mechanically stable before connecting any wiring.\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\nConnect the chassis to a dedicated protective earth (PE) ground point using a low-impedance conductor. A reliable ground connection is critical for safety and noise immunity.\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\nConnect the AC power supply cable to a stable, correctly rated power source. Use a circuit with appropriate overcurrent protection.\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e5\u003c\/span\u003e\nConnect all communication and I\/O cables (Ethernet, PROFIBUS, USB, Serial). Ensure proper cable shielding is terminated correctly at the connector or chassis ground to minimize electromagnetic interference.\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e6\u003c\/span\u003e\nAfter verifying all connections are secure and correct, re-apply power to the unit and proceed with system configuration and software setup.\n\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716610027883,"sku":"6ES7647-6BB10-0GB1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6es7647-6bb10-0gb1-bio4x1bdr2u_a4e4c500-3bf1-4ba8-bd0f-835a2dd769af.jpg?v=1767086664","url":"https:\/\/www.plcprotech.com\/id\/products\/siemens-6es7647-6bb10-0gb1-simatic-box-pc-627b-industrial-pc","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}