{"product_id":"siemens-6gk5308-2fl10-2aa3-scalance-x308-2-managed-industrial-ethernet-switch","title":"Siemens 6GK5308-2FL10-2AA3 SCALANCE X308-2 Managed Industrial Ethernet Switch","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Siemens 6GK5308-2FL10-2AA3 is a SCALANCE X308-2 series managed plus Industrial Ethernet switch, engineered for reliable network management in demanding automation systems. This device provides a versatile port configuration with \u003cstrong\u003e2x 1000 Mbit\/s multimode SC fiber ports\u003c\/strong\u003e, \u003cstrong\u003e1x 10\/100\/1000 Mbit\/s RJ45 port\u003c\/strong\u003e, and \u003cstrong\u003e7x 10\/100 Mbit\/s RJ45 ports\u003c\/strong\u003e to support hybrid copper and fiber optic network infrastructures. It functions as a PROFINET IO device and includes an integrated redundancy manager to maintain high network availability. On-device diagnostics are facilitated by integrated LEDs and an error signaling contact with a select\/set button. The switch supports key office and IT features, including RSTP, VLAN, and IGMP, for advanced network segmentation and traffic control. A C-PLUG is included for simplified device replacement and commissioning.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 10px;\"\u003e\n  \u003cli\u003eManaged Plus Industrial Ethernet (IE) switch functionality.\u003c\/li\u003e\n  \u003cli\u003ePROFINET IO device for seamless integration into Siemens automation environments.\u003c\/li\u003e\n  \u003cli\u003eIntegrated redundancy manager for enhanced network reliability.\u003c\/li\u003e\n  \u003cli\u003eOnboard LED diagnostics and error signaling contact for status monitoring.\u003c\/li\u003e\n  \u003cli\u003eSupports office features such as RSTP, VLAN, and IGMP.\u003c\/li\u003e\n  \u003cli\u003eIncludes a C-PLUG configuration memory module in the scope of delivery.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 10px;\"\u003e\n  \u003cli\u003ePlant-wide networking in manufacturing and process industries.\u003c\/li\u003e\n  \u003cli\u003eMachine-level networks requiring high-speed fiber optic uplinks.\u003c\/li\u003e\n  \u003cli\u003eIntegration of Ethernet-based devices in PROFINET control systems.\u003c\/li\u003e\n  \u003cli\u003eControl cabinet installations for automation and motion control applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr\u003e\n        \u003cth style=\"background-color: #f7fafc; padding: 12px; border-bottom: 2px solid #e2e8f0; text-align: left; font-weight: 600; color: #2d3748;\"\u003eSpecification\u003c\/th\u003e\n        \u003cth style=\"background-color: #f7fafc; padding: 12px; border-bottom: 2px solid #e2e8f0; text-align: left; font-weight: 600; color: #2d3748;\"\u003eValue\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px; color: #2d3748; vertical-align: top;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; color: #2d3748; vertical-align: top;\"\u003eSiemens\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0; background-color: #fdfdff;\"\u003e\n        \u003ctd style=\"padding: 12px; color: #2d3748; vertical-align: top;\"\u003eProduct Series\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; color: #2d3748; vertical-align: top;\"\u003eSCALANCE X308-2\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px; color: #2d3748; vertical-align: top;\"\u003eSKU \/ Order Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; color: #2d3748; vertical-align: top;\"\u003e6GK5308-2FL10-2AA3\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0; background-color: #fdfdff;\"\u003e\n        \u003ctd style=\"padding: 12px; color: #2d3748; vertical-align: top;\"\u003eProduct Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; color: #2d3748; vertical-align: top;\"\u003eManaged Industrial Ethernet Switch\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px; color: #2d3748; vertical-align: top;\"\u003eFiber Optic Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; color: #2d3748; vertical-align: top;\"\u003e2x 1000 Mbit\/s Multimode (MM) SC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0; background-color: #fdfdff;\"\u003e\n        \u003ctd style=\"padding: 12px; color: #2d3748; vertical-align: top;\"\u003eGigabit Ethernet Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; color: #2d3748; vertical-align: top;\"\u003e1x 10\/100\/1000 Mbit\/s RJ45\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px; color: #2d3748; vertical-align: top;\"\u003eFast Ethernet Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; color: #2d3748; vertical-align: top;\"\u003e7x 10\/100 Mbit\/s RJ45\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0; background-color: #fdfdff;\"\u003e\n        \u003ctd style=\"padding: 12px; color: #2d3748; vertical-align: top;\"\u003eManagement Protocols\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; color: #2d3748; vertical-align: top;\"\u003ePROFINET IO, RSTP, VLAN, IGMP\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px; color: #2d3748; vertical-align: top;\"\u003eDiagnostics\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; color: #2d3748; vertical-align: top;\"\u003eLEDs, Error Signaling Contact\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0; background-color: #fdfdff;\"\u003e\n        \u003ctd style=\"padding: 12px; color: #2d3748; vertical-align: top;\"\u003eIncluded Accessories\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; color: #2d3748; vertical-align: top;\"\u003eC-PLUG\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px; color: #2d3748; vertical-align: top;\"\u003ePLM Product Phase\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; color: #2d3748; vertical-align: top;\"\u003ePhase-Out\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0; background-color: #fdfdff;\"\u003e\n        \u003ctd style=\"padding: 12px; color: #2d3748; vertical-align: top;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; color: #2d3748; vertical-align: top;\"\u003e1.40 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px; color: #2d3748; vertical-align: top;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; color: #2d3748; vertical-align: top;\"\u003e12.00 x 12.30 x 12.50 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0; background-color: #fdfdff;\"\u003e\n        \u003ctd style=\"padding: 12px; color: #2d3748; vertical-align: top;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; color: #2d3748; vertical-align: top;\"\u003e85176200\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px; color: #2d3748; vertical-align: top;\"\u003eECCN\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; color: #2d3748; vertical-align: top;\"\u003eEAR99\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background-color: #fdfdff;\"\u003e\n        \u003ctd style=\"padding: 12px; color: #2d3748; vertical-align: top;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; color: #2d3748; vertical-align: top;\"\u003eGermany (Estimate)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px; margin-top: 24px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 5px solid #c53030; padding: 16px; margin-bottom: 20px;\"\u003e\n  \u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e Electrical hazard. Disconnect and lock out all power sources before installation or maintenance. Work must be performed by qualified personnel only. Failure to comply can result in severe injury or death.\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0;\"\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n    \u003cspan\u003eMount the switch securely onto a standard 35mm DIN rail inside a suitable enclosure that protects against environmental contaminants and provides adequate ventilation. Ensure a solid mechanical connection.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n    \u003cspan\u003eConnect the functional earth (FE) terminal to the local equipotential bonding system. A low-impedance ground connection is critical for noise immunity and safety.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n    \u003cspan\u003eConnect the DC power supply to the designated power input terminals. Verify the voltage and polarity are correct before energizing the unit. Use appropriately sized conductors and secure them firmly in the terminals.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n    \u003cspan\u003eConnect network devices using shielded RJ45 cables for copper ports and appropriate multimode fiber optic cables for the SC ports. Ensure connectors are clean and fully seated. Route data cables separately from high-voltage power lines.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 16px;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #fff; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e5\u003c\/span\u003e\n    \u003cspan\u003eAfter all connections are made, restore power to the cabinet and verify the device's status LEDs for correct operation, including power, link status, and network activity.\u003c\/span\u003e\n  \u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716665930091,"sku":"6GK5308-2FL10-2AA3","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6gk5308-2fl10-2aa3-sofqt3i3t1w_dae084d1-0bb2-4f9b-a577-b863f3e43904.jpg?v=1767087631","url":"https:\/\/www.plcprotech.com\/id\/products\/siemens-6gk5308-2fl10-2aa3-scalance-x308-2-managed-industrial-ethernet-switch","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}