{"product_id":"siemens-simatic-ipc677d-6av7260-1da30-1ex6-panel-pc","title":"Siemens SIMATIC IPC677D 6AV7260-1DA30-1EX6 Panel PC","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px; margin-bottom: 16px;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThis Siemens SIMATIC IPC677D, model 6AV7260-1DA30-1EX6, is an industrial Panel PC designed for robust performance in automation and control applications. It integrates a \u003cstrong\u003e19-inch touchscreen display\u003c\/strong\u003e with a resolution of 1366x768 and is powered by an Intel \u003cstrong\u003eCore i3-4330TE processor\u003c\/strong\u003e. The unit is equipped with \u003cstrong\u003e8 GB of DDR3 RAM\u003c\/strong\u003e, a \u003cstrong\u003e500 GB SATA HDD\u003c\/strong\u003e, and a comprehensive set of I\/O including dual Gigabit Ethernet, USB 3.0, and a serial port. Integrated monitoring for watchdog, temperature, and fan status, along with an onboard RAID controller, ensures high system availability. This Panel PC operates on a \u003cstrong\u003e24 V DC\u003c\/strong\u003e industrial power supply.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px; margin-bottom: 16px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 10px;\"\u003e\n    \u003cli\u003e19-inch touchscreen display (1366 x 768 resolution)\u003c\/li\u003e\n    \u003cli\u003eIntel Core i3-4330TE processor (2.4 GHz, 2 Cores \/ 4 Threads)\u003c\/li\u003e\n    \u003cli\u003e8 GB DDR3 1600 DIMM memory\u003c\/li\u003e\n    \u003cli\u003e500 GB SATA Hard Disk Drive (HDD)\u003c\/li\u003e\n    \u003cli\u003eDual 10\/100\/1000 Mbit\/s Ethernet ports\u003c\/li\u003e\n    \u003cli\u003eMultiple USB ports including 4x USB 3.0 and a front-accessible port\u003c\/li\u003e\n    \u003cli\u003eOnboard RAID controller for data redundancy\u003c\/li\u003e\n    \u003cli\u003eIntegrated system monitoring for watchdog, temperature, and fan\u003c\/li\u003e\n    \u003cli\u003ePowered by a 24 V DC industrial power supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px; margin-bottom: 16px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 10px;\"\u003e\n    \u003cli\u003eHuman-Machine Interface (HMI) stations\u003c\/li\u003e\n    \u003cli\u003eSCADA and process visualization nodes\u003c\/li\u003e\n    \u003cli\u003eMachine control and data acquisition terminals\u003c\/li\u003e\n    \u003cli\u003eIndustrial data logging and reporting\u003c\/li\u003e\n    \u003cli\u003eFactory floor information systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px; margin-bottom: 16px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #ccc;\"\u003e\n    \u003cthead\u003e\n        \u003ctr\u003e\n            \u003cth style=\"background-color: #f2f2f2; padding: 12px; text-align: left; border-bottom: 1px solid #ccc; color: #2d3748;\"\u003eSpecification\u003c\/th\u003e\n            \u003cth style=\"background-color: #f2f2f2; padding: 12px; text-align: left; border-bottom: 1px solid #ccc; color: #2d3748;\"\u003eValue\u003c\/th\u003e\n        \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n        \u003ctr style=\"border-bottom: 1px solid #ccc;\"\u003e\n\u003ctd style=\"padding: 12px; color: #2d3748;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; color: #2d3748;\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #ccc; background-color: #fafafa;\"\u003e\n\u003ctd style=\"padding: 12px; color: #2d3748;\"\u003eProduct Series\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; color: #2d3748;\"\u003eSIMATIC IPC677D\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #ccc;\"\u003e\n\u003ctd style=\"padding: 12px; color: #2d3748;\"\u003ePart Number\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; color: #2d3748;\"\u003e6AV7260-1DA30-1EX6\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #ccc; background-color: #fafafa;\"\u003e\n\u003ctd style=\"padding: 12px; color: #2d3748;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; color: #2d3748;\"\u003ePanel PC\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #ccc;\"\u003e\n\u003ctd style=\"padding: 12px; color: #2d3748;\"\u003eDisplay\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; color: #2d3748;\"\u003e19\" Touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #ccc; background-color: #fafafa;\"\u003e\n\u003ctd style=\"padding: 12px; color: #2d3748;\"\u003eDisplay Resolution\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; color: #2d3748;\"\u003e1366 x 768\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #ccc;\"\u003e\n\u003ctd style=\"padding: 12px; color: #2d3748;\"\u003eProcessor\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; color: #2d3748;\"\u003eIntel Core i3-4330TE (2C\/4T, 2.4 GHz, 4 MB cache, VT-x)\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #ccc; background-color: #fafafa;\"\u003e\n\u003ctd style=\"padding: 12px; color: #2d3748;\"\u003eMemory\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; color: #2d3748;\"\u003e8 GB DDR3 1600 DIMM\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #ccc;\"\u003e\n\u003ctd style=\"padding: 12px; color: #2d3748;\"\u003eStorage\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; color: #2d3748;\"\u003e500 GB HDD SATA\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #ccc; background-color: #fafafa;\"\u003e\n\u003ctd style=\"padding: 12px; color: #2d3748;\"\u003eOperating System\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; color: #2d3748;\"\u003eWindows 10 Pro or Windows 11 Pro, 64-bit, MUI (en, de, fr, it, es)\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #ccc;\"\u003e\n\u003ctd style=\"padding: 12px; color: #2d3748;\"\u003eEthernet Ports\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; color: #2d3748;\"\u003e2x 10\/100\/1000 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #ccc; background-color: #fafafa;\"\u003e\n\u003ctd style=\"padding: 12px; color: #2d3748;\"\u003eUSB Ports\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; color: #2d3748;\"\u003e4x USB V3.0, 2x additional USB, 1x front USB\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #ccc;\"\u003e\n\u003ctd style=\"padding: 12px; color: #2d3748;\"\u003eSerial Port\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; color: #2d3748;\"\u003e1x COM1\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #ccc; background-color: #fafafa;\"\u003e\n\u003ctd style=\"padding: 12px; color: #2d3748;\"\u003eExpansion Slots\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; color: #2d3748;\"\u003e2x PCI (1 slot occupied)\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #ccc;\"\u003e\n\u003ctd style=\"padding: 12px; color: #2d3748;\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; color: #2d3748;\"\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #ccc; background-color: #fafafa;\"\u003e\n\u003ctd style=\"padding: 12px; color: #2d3748;\"\u003eProduct Lifecycle Status\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; color: #2d3748;\"\u003ePhase-Out\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #ccc;\"\u003e\n\u003ctd style=\"padding: 12px; color: #2d3748;\"\u003eShipping Weight\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; color: #2d3748;\"\u003e17.00 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #ccc; background-color: #fafafa;\"\u003e\n\u003ctd style=\"padding: 12px; color: #2d3748;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; color: #2d3748;\"\u003e67.0 x 83.0 x 11.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #ccc;\"\u003e\n\u003ctd style=\"padding: 12px; color: #2d3748;\"\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; color: #2d3748;\"\u003eGermany (Estimate)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px; margin-top: 24px; margin-bottom: 16px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 5px solid #c53030; padding: 16px; margin-bottom: 20px;\"\u003e\n    \u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e Disconnect all power sources before installation or maintenance. This unit operates on 24 V DC; incorrect voltage or polarity can cause permanent damage. All work must be performed by qualified personnel in accordance with local electrical codes.\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0;\"\u003e\n    \u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n        \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n        \u003cdiv\u003e\n            \u003cstrong\u003ePanel Mounting:\u003c\/strong\u003e Ensure the control cabinet or panel cutout dimensions match the IPC's specifications for a secure fit. Use all provided mounting clamps and tighten them evenly to the manufacturer's recommended torque to ensure a proper seal and prevent chassis distortion.\n        \u003c\/div\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n        \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n        \u003cdiv\u003e\n            \u003cstrong\u003ePower Connection:\u003c\/strong\u003e Connect a stable, filtered 24 V DC power source to the designated power input terminals. Verify correct polarity (+\/-) before applying power. Use appropriately sized conductors for the load and distance from the power supply.\n        \u003c\/div\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n        \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n        \u003cdiv\u003e\n            \u003cstrong\u003eProtective Earth (PE) Grounding:\u003c\/strong\u003e Connect the chassis grounding terminal to the main protective earth bus bar of the cabinet using a low-impedance conductor. A proper ground connection is critical for operator safety and noise immunity.\n        \u003c\/div\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n        \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n        \u003cdiv\u003e\n            \u003cstrong\u003eI\/O and Network Cabling:\u003c\/strong\u003e Connect Ethernet, USB, and serial cables. Route signal cables separately from high-voltage power lines to minimize electromagnetic interference (EMI). Use shielded cables for network and serial communications where specified, ensuring shields are properly terminated.\n        \u003c\/div\u003e\n    \u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n        \u003cspan style=\"background-color: #2b6cb0; color: white; border-radius: 50%; width: 24px; height: 24px; text-align: center; line-height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e5\u003c\/span\u003e\n        \u003cdiv\u003e\n            \u003cstrong\u003eSystem Startup:\u003c\/strong\u003e After verifying all connections, apply power to the unit. The pre-installed operating system should boot automatically. Proceed with application software installation and system configuration as required.\n        \u003c\/div\u003e\n    \u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52715807768939,"sku":"6AV7260-1DA30-1EX6","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6av7260-1da30-1ex6-qkbkhm2sldq_065c7096-e3c5-4d57-891e-8266be2e235c.jpg?v=1767071361","url":"https:\/\/www.plcprotech.com\/id\/products\/siemens-simatic-ipc677d-6av7260-1da30-1ex6-panel-pc","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}