{"product_id":"siemens-simovert-masterdrives-du-dt-filter-6se7016-2fb87-1fd0-z","title":"Siemens SIMOVERT MASTERDRIVES Filter du\/dt 6SE7016-2FB87-1FD0-Z","description":"\u003cp\u003eDescription\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003e6SE7016-2FB87-1FD0-Z\u003c\/strong\u003e is a \u003cstrong\u003edu\/dt filter\u003c\/strong\u003e from the \u003cstrong\u003eSIMOVERT MASTERDRIVES\u003c\/strong\u003e series, manufactured by \u003cstrong\u003eSiemens\u003c\/strong\u003e. This filter is designed to mitigate the steep voltage rise times (du\/dt) generated by Pulse Width Modulation (PWM) in variable frequency drives. By limiting these voltage spikes, the filter protects motor insulation and cable systems from premature degradation, extending the lifespan of the drive-motor assembly in demanding industrial applications. Rated for both 380-460V AC (at 6.1A) and 500-575V AC (at 6.2A) systems, this robust component is a critical solution for maintaining process reliability.\u003c\/p\u003e\n\u003cp\u003eFeatures\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Spike Suppression:\u003c\/strong\u003e Effectively reduces the du\/dt rate to protect motor windings and insulation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual-Voltage Capability:\u003c\/strong\u003e Suitable for 380-460V AC and 500-575V AC three-phase power systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMasterdrives Compatibility:\u003c\/strong\u003e Specifically engineered for integration within the Siemens SIMOVERT MASTERDRIVES ecosystem.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Robustness:\u003c\/strong\u003e Designed to withstand the rigors of heavy-duty manufacturing environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eTechnical Specifications\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Range\u003c\/td\u003e\n\u003ctd\u003eSIMOVERT MASTERDRIVES\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e6SE7016-2FB87-1FD0-Z\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003edu\/dt Filter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current (380-460V)\u003c\/td\u003e\n\u003ctd\u003e6.1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current (500-575V)\u003c\/td\u003e\n\u003ctd\u003e6.2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e20.00kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e48.30 x 40.60 x 35.60 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommodity Code\u003c\/td\u003e\n\u003ctd\u003e85044095\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePLM Product Phase\u003c\/td\u003e\n\u003ctd\u003eObsolete\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eInstallation Guidelines\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVentilation:\u003c\/strong\u003e Due to the power dissipated by the filter, ensure it is installed in an enclosure with adequate forced-air ventilation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProximity:\u003c\/strong\u003e Install the filter as close to the drive output as possible to minimize the impact of cable length on voltage reflections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Secure a solid, low-impedance connection between the filter chassis and the system ground plate to ensure effective EMI shielding.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Selection:\u003c\/strong\u003e Use shielded power cables between the filter and the motor to minimize radiated electromagnetic noise.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety:\u003c\/strong\u003e Because this is an obsolete unit, ensure all mounting brackets and electrical terminals are inspected for integrity before integration, and always perform installation with the power locked out.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716780913003,"sku":"6SE7016-2FB87-1FD0-Z","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6se7016-2fb87-1fd0-z-gp4h0knkj5b_028d4d30-6683-4104-8a94-c2291c66edb4.jpg?v=1767089537","url":"https:\/\/www.plcprotech.com\/id\/products\/siemens-simovert-masterdrives-du-dt-filter-6se7016-2fb87-1fd0-z","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}