{"product_id":"triconex-3703e-tricon-isolated-analog-input-module","title":"Triconex 3703E Tricon Isolated Analog Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eTriconex 3703E\u003c\/strong\u003e is a highly reliable Isolated Analog Input Module designed specifically for Tricon systems. As a core component of Safety Instrumented Systems (SIS), this module features three independent input channels to perform high-accuracy signal acquisition from field sensors using Triple Modular Redundancy (TMR) architecture. The \u003cstrong\u003eTriconex 3703E\u003c\/strong\u003e supports 0-5 VDC or 0-10 VDC differential isolated signal inputs, which are software-configurable via TriStation 1131. Each channel provides independent signal conditioning and opto-isolation between the field and the system, effectively preventing a single-channel failure from affecting other channels. The module utilizes a built-in Mid-Value Selection algorithm to vote on the three sets of acquired data, ensuring the highest data integrity, functional safety, and continuous system availability in critical industrial protection applications.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUtilizes Triple Modular Redundancy (TMR) architecture with three completely independent input channels.\u003c\/li\u003e\n\u003cli\u003eSupports 16-point differential isolated analog inputs, providing up to 200V peak channel-to-channel isolation.\u003c\/li\u003e\n\u003cli\u003eInput voltage ranges are configurable via TriStation 1131 software for 0-5 VDC or 0-10 VDC (including a +6% overrange capability).\u003c\/li\u003e\n\u003cli\u003eFeatures comprehensive, continuous online self-diagnostics to monitor channel operational status in real time.\u003c\/li\u003e\n\u003cli\u003eSupports Hot-Spare functionality, allowing replacement of faulty modules while the system is online without interrupting the process.\u003c\/li\u003e\n\u003cli\u003eMechanically keyed design prevents incorrect insertion into the chassis slots.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEmergency Shutdown Systems (ESD)\u003c\/li\u003e\n\u003cli\u003eFire and Gas Detection Systems (F\u0026amp;G)\u003c\/li\u003e\n\u003cli\u003eBoiler and Burner Management Systems (BMS)\u003c\/li\u003e\n\u003cli\u003eHigh-reliability control for steam turbines and large rotating machinery\u003c\/li\u003e\n\u003cli\u003eSafety parameter monitoring in critical process industries\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTriconex (Invensys)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3703E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTMR, Analog Input (AI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Input Points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16, differential, isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolated Points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0-5 VDC or 0-10 VDC (selected via TriStation 1131)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Update Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.15% of FSR, from 0 to 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Resistance (Load)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 MΩ (DC) minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower-Off Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 MΩ (DC) minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommon Mode Rejection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-90 dB @ 60Hz minimum, -100 dB @ DC minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommon Mode Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+200V peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLeg-to-Leg Isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 kΩ typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNormal Mode Rejection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-3 dB @ 8Hz, -17 dB @ 60Hz, -23 dB @ 120Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Overrange Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150 VDC \/ 115 VAC continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.7 to 6.0 lbs. (2.1 kg to 2.7 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard Tricon I\/O slot format\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 60 °C ambient (measured at chassis bottom)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 to 75 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5% to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Slot Positioning\u003c\/strong\u003e: The module features a mechanically keyed design to ensure proper insertion into the designated Tricon chassis slot. Push the module smoothly into place and securely tighten the retention screws.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal Wiring Network\u003c\/strong\u003e: Connection must be made via a dedicated External Termination Panel (ETP), which interfaces with the Tricon chassis backplane using standard interface cables.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHot-Spare Configuration\u003c\/strong\u003e: To enable Hot-Spare functionality, an identical backup module can be installed in the adjacent empty slot. The system will automatically execute a bumpless online switchover if a primary module fault is detected.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Protection\u003c\/strong\u003e: Since Tricon systems do not offer special protection against dust or corrosive atmospheres, the module must be installed within an industrial control enclosure that meets NEMA protection rating standards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTÜV Rheinland\u003c\/strong\u003e: Certified for SIL 1-3 applications (in compliance with IEC 61508 safety requirements), EN 54 (fire and gas detection standard), and NFPA 72\/8501\/8502.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA\u003c\/strong\u003e: Complies with North American electrical safety standards and is approved for use in designated jurisdictions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFactory Mutual (FM)\u003c\/strong\u003e: Suitable for Class I, Division 2, Temperature T4, Groups A, B, C, D hazardous indoor locations (or outdoor enclosures meeting NEMA 4 requirements).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE Mark\u003c\/strong\u003e: Complies with the EU EMC Directive (89\/336\/EEC) and Low Voltage Directive (72\/23\/EEC).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eU.S. NRC\u003c\/strong\u003e: Certified by the U.S. Nuclear Regulatory Commission (NRC) for use in nuclear Class 1E safety control applications.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":53102420558187,"sku":"3703E","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/3703e-fuyp2csn22r.png?v=1776137112","url":"https:\/\/www.plcprotech.com\/id\/products\/triconex-3703e-tricon-isolated-analog-input-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}