{"title":"Allen-Bradley Compact 5000","description":"\u003cp\u003eAllen-Bradley Compact 5000 (5069-) is a high-performance, chassis-less I\/O system designed to complement the latest Logix controllers. Its architecture utilizes a high-speed backplane and granular modules, providing enhanced system throughput and precision. Technical characteristics include support for Gigabit EtherNet\/IP, integrated safety modules, and a compact, high-density design. Functionally, the Compact 5000 series is optimized for high-speed motion and data-intensive applications, often serving as the primary I\/O for \u003ca href=\"https:\/\/www.plcprotech.com\/collections\/allen-bradley-compactlogix\"\u003eCompactLogix 5380\u003c\/a\u003e controllers. This system is essential for modern smart machines requiring high-resolution timing and seamless connectivity in the Industrial Internet of Things (IIoT) era.\u003c\/p\u003e","products":[{"product_id":"allen-bradley-5069-l306erm-compactlogix-5380-controller","title":"Allen-Bradley 5069-L306ERM CompactLogix 5380 Controller","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-L306ERM\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance, mid-range controller from the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCompactLogix 5380\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efamily by Rockwell Automation. Designed for modern industrial applications, it provides increased processing power, high-speed I\/O throughput, and integrated motion control capabilities. It is particularly well-suited for machine builders requiring precision, scalability, and enhanced security within the Logix 5000 ecosystem.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e5069-L306ERM\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAllen-Bradley (Rockwell Automation)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eUser Memory\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.6 MB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIntegrated Motion\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 2 CIP Motion axes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEthernet Nodes\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupports up to 16 Ethernet\/IP nodes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLocal I\/O Modules\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupports up to 8 local 5069 I\/O modules\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Ports\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 Ethernet (Gigabit) \/ 1 USB (Programming)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModule requires external 5069-RTB22 or similar for DC power\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProgramming Software\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStudio 5000 Logix Designer (v28 or later)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eCore Functionalities\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003e1. Integrated Motion on EtherNet\/IP\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe \"M\" in the model name signifies\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIntegrated Motion\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecapability. The 5069-L306ERM supports up to 2 axes of coordinated motion, allowing for precise control of Kinetix drives and motors over a standard Ethernet cable without the need for dedicated motion hardware.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e2. Dual Gigabit Ethernet Ports\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThis controller features two 1-Gigabit Ethernet ports that can be configured in two modes:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDual-IP Mode:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAssign separate IP addresses to each port to isolate plant-floor traffic from the enterprise network.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLinear\/DLR Mode:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAllows for Device Level Ring (DLR) topologies, providing network resiliency so that a single cable break does not stop the system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003e3. 5069 I\/O Platform\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eIt utilizes the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069 Compact I\/O\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eplatform, which offers significantly faster backplane speeds compared to older generations. This results in reduced latency and more deterministic I\/O performance for high-speed counting or sensing applications.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical FAQs\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between the 5069-L306ER and the 5069-L306ERM?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eER\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eversion is a standard controller with no integrated motion capability. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eERM\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eversion includes support for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCIP Motion\u003c\/strong\u003e, making it capable of controlling synchronized servo axes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 5069-L306ERM require a battery?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. Like most modern Logix controllers, it uses internal non-volatile memory and energy storage (capacitors) to back up the user program and data during a power loss, eliminating the need for periodic battery replacement.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use 1769-series I\/O modules with this controller?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The 5380 series is only compatible with the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eI\/O platform for local modules. To use 1769 modules, you would need to connect to them as remote I\/O via an Ethernet adapter (e.g., 1769-AENTR).\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering \u0026amp; Installation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Architecture:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe controller requires two separate DC power inputs:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMOD Power\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(for the controller and module electronics) and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSA Power\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(for field-side power to the I\/O). These must be connected via a removable terminal block (RTB).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSecurity Features:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 5069-L306ERM includes controller-based security features, such as digitally signed firmware and role-based access control, to help protect against unauthorized modifications and cyber threats.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIt is designed for standard DIN rail mounting. Ensure adequate clearance (approx. 50mm) above and below the module to allow for passive convection cooling, as this series can run warm during high-load processing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering Advantages\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-L306ERM\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003estands out for its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eLow-Latency Performance\u003c\/strong\u003e. With a Gigabit backplane and high-speed task execution, it can handle complex logic and motion tasks with minimal jitter. It serves as an ideal entry-point for motion applications that don't require the massive memory or high axis count of the 1756 ControlLogix line, but still demand the reliability and precision of the Allen-Bradley brand.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":53083968635243,"sku":"5069-L306ERM","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/5069-L306ERM_2.png?v=1775992178"},{"product_id":"allen-bradley-5069-l310erm-compactlogix-5380-controller","title":"Allen-Bradley 5069-L310ERM CompactLogix 5380 Controller","description":"\u003cp\u003e\u003cspan class=\"citation-382\"\u003eThe \u003c\/span\u003e\u003cstrong\u003e5069-L310ERM\u003c\/strong\u003e\u003cspan class=\"citation-382\"\u003e is a high-performance, mid-range controller within the \u003c\/span\u003e\u003cstrong\u003eCompactLogix 5380\u003c\/strong\u003e\u003cspan class=\"citation-382 citation-end-382\"\u003e family.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e It is designed to meet the high-speed processing and data-intensive requirements of modern \"smart\" machines. This controller is a significant step up from the entry-level L306 model, offering expanded memory and node capacity while maintaining the same compact form factor.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eUser Memory\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 MB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIntegrated Motion\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to \u003cstrong\u003e4 axes\u003c\/strong\u003e (CIP Motion over EtherNet\/IP)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEthernet Nodes\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupports up to \u003cstrong\u003e24 nodes\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLocal I\/O Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 8 local 5069 Compact I\/O modules\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Ports\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 Ethernet (Gigabit) \/ 1 USB 2.0 (Programming)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNon-volatile Memory\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 GB (via 1784-SD2 card)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProgramming\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStudio 5000 Logix Designer (v28 or later)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eCore Capabilities\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003e1. Scalable Motion Control\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe \"M\" designation confirms this controller is motion-capable. \u003cspan class=\"citation-381\"\u003eIt supports up to \u003c\/span\u003e\u003cstrong\u003e4 axes of coordinated CIP Motion\u003c\/strong\u003e\u003cspan class=\"citation-381 citation-end-381\"\u003e, allowing for precise control of servo drives (like the Kinetix 5500 or 5700) over a standard Ethernet network.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003cspan class=\"citation-380 citation-end-380\"\u003eIt can also manage up to 256 non-integrated motion axes.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e2. Advanced Gigabit Networking\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan class=\"citation-379 citation-end-379\"\u003eEquipped with dual 1-Gbps Ethernet ports, the 5069-L310ERM supports high-speed data exchange and flexible network topologies:\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDual-IP Mode:\u003c\/strong\u003e Allows the controller to have two different IP addresses—one for the machine-level I\/O network and one for the plant-level enterprise network—improving security and traffic isolation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLinear\/DLR Mode:\u003c\/strong\u003e\u003cspan class=\"citation-378 citation-end-378\"\u003e Supports Device Level Ring (DLR) for high network availability; if one cable in the ring breaks, the system continues to communicate without interruption.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003e3. Enhanced System Performance\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003ePart of the 5380 series, this controller features a high-speed backplane that significantly reduces I\/O scan times compared to the older 1769 CompactLogix series. This makes it an excellent choice for applications requiring rapid safety reaction times or high-speed registration.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical FAQs\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the 5069-L310ERM compare to the 5069-L306ERM?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"citation-377\"\u003eThe \u003c\/span\u003e\u003cstrong\u003eL310ERM\u003c\/strong\u003e\u003cspan class=\"citation-377\"\u003e offers nearly double the user memory (\u003c\/span\u003e\u003cstrong\u003e1 MB\u003c\/strong\u003e\u003cspan class=\"citation-377\"\u003e vs 0.6 MB), supports more Ethernet nodes (\u003c\/span\u003e\u003cstrong\u003e24\u003c\/strong\u003e\u003cspan class=\"citation-377\"\u003e vs 16), and doubles the number of supported CIP motion axes (\u003c\/span\u003e\u003cstrong\u003e4\u003c\/strong\u003e\u003cspan class=\"citation-377 citation-end-377\"\u003e vs 2).\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat power is required for this controller?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt requires a dual-feed DC power supply:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-376\"\u003e\u003c\/span\u003e\u003cstrong\u003eMOD Power (18-32V DC):\u003c\/strong\u003e\u003cspan class=\"citation-376 citation-end-376\"\u003e Powers the controller's internal logic.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-375\"\u003e\u003c\/span\u003e\u003cstrong\u003eSA Power (18-32V DC):\u003c\/strong\u003e\u003cspan class=\"citation-375 citation-end-375\"\u003e Provides power for the field-side circuitry of the connected I\/O modules.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it require a battery for program backup?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The 5069-L310ERM uses an internal energy storage module (capacitors) to write the program to non-volatile memory during a power loss, eliminating the need for lithium batteries.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering \u0026amp; Installation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e Horizontal mounting on a standard 35 mm DIN rail is required. Ensure at least 50 mm (2 in.) of clearance above and below the unit for convection cooling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Placement:\u003c\/strong\u003e The controller must be the leftmost module in a local 5069 I\/O bank.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRemovable Terminal Blocks (RTB):\u003c\/strong\u003e Ensure you have the required RTB (typically 5069-RTB18 or 5069-RTB14) to connect the MOD and SA power feeds, as these are often sold separately.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering Advantages\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e5069-L310ERM\u003c\/strong\u003e is ideal for applications that have outgrown the memory constraints of entry-level controllers but do not yet require the high axis counts of the L320 or L330 models. Its Gigabit Ethernet performance ensures that the controller can handle the increased traffic of modern IIoT (Industrial Internet of Things) devices and high-resolution HMI screens without compromising logic execution speed.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":53083969159531,"sku":"5069-L310ERM","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/Allen-Bradley5069-L310ERM.png?v=1775992904"},{"product_id":"allen-bradley-5069-l310er-nse-compactlogix-5380-no-stored-energy-controller","title":"Allen-Bradley 5069-L310ER-NSE CompactLogix 5380 No-Stored-Energy Controller","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-L310ER-NSE\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a specialized version of the CompactLogix 5380 controller designed for environments where \"stored energy\" is a safety or security risk. While it retains the core high-performance characteristics of the 5380 series, it is specifically engineered for hazardous or restricted areas—such as mining, explosives manufacturing, or highly secure data centers—where traditional energy-storing capacitors are prohibited.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e5069-L310ER-NSE\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAllen-Bradley (Rockwell Automation)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eUser Memory\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 MB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNSE Feature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNo Stored Energy\u003c\/strong\u003e (No internal capacitors\/batteries)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEthernet Nodes\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupports up to 24 Ethernet\/IP nodes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLocal I\/O Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 8 local 5069 Compact I\/O modules\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Ports\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 Ethernet (Gigabit) \/ 1 USB (Programming)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProgramming Software\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStudio 5000 Logix Designer (v28 or later)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eCore Capabilities\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003e1. No Stored Energy (NSE) Technology\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eStandard CompactLogix controllers use internal energy storage modules (capacitors) to write data to non-volatile memory during a power loss. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNSE version\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eremoves these components. This ensures that when power is cut, the energy dissipated is below the threshold required to trigger an ignition in explosive atmospheres, meeting strict\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHazardous Area\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIntrinsically Safe\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erequirements.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e2. Dual Gigabit Ethernet \u0026amp; High-Speed Performance\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eDespite its specialized safety features, it maintains the performance of the 5380 series:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGigabit Throughput:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDual 1-Gbps ports support high-speed data exchange.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDual-IP Mode:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAllows for network segmentation, isolating machine-level I\/O traffic from higher-level enterprise networks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDLR Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports Device Level Ring for high network availability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003e3. High-Speed 5069 Backplane\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eIt utilizes the 5069 Compact I\/O platform, which provides much faster scan times and higher accuracy for time-critical applications compared to the older 1769 series.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical FAQs\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the NSE version handle data during power loss?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBecause the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-L310ER-NSE\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003elacks the internal energy to write data to the SD card during an unexpected power down, any data not already saved to the non-volatile memory (or synchronized to a SCADA\/DB system) will be lost. In these applications, engineers typically use an external Uninterruptible Power Supply (UPS) if data retention is critical.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this for motion control?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-L310ER-NSE\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edoes not have the \"M\" designation. If you require integrated motion in a no-stored-energy format, you would need to look for an \"ERM-NSE\" variant, though the L310ER-NSE is primarily used for discrete and process logic.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the \"SA Power\" and \"MOD Power\" on this unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 5069 architecture separates the power feeds:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMOD Power:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePowers the internal controller logic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSA Power:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePowers the field-side circuitry of the I\/O modules. Both must be wired via a removable terminal block (RTB).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering \u0026amp; Installation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExternal Power Dependency:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSince this unit cannot back itself up, ensure your application logic is designed for \"clean\" restarts. Use the 1784-SD2 card to store the project, but be aware that tag values will revert to their last saved state upon power cycling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard horizontal DIN rail mounting. Like other 5380 controllers, it requires adequate spacing for thermal dissipation as the high-speed processor generates significant heat.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSecure Environments:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe NSE series is frequently mandated in secure government or military facilities where the ability of a device to hold a charge (and thus potentially maintain data in memory) after power removal is viewed as a security vulnerability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering Advantages\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-L310ER-NSE\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis the industry standard for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHazardous Location Safety\u003c\/strong\u003e. It allows plant managers to deploy a high-speed, modern Logix controller into zones where they previously had to rely on older, less capable technology. By eliminating stored energy, Rockwell has provided a path to modernize explosives handling, chemical processing, and underground mining operations without compromising safety protocols.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":53083971518827,"sku":"5069-L310ER-NSE","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/5069-L310ER-NSE.png?v=1775993302"},{"product_id":"allen-bradley-5069-rtb18-screw-removable-terminal-block","title":"Allen-Bradley 5069-RTB18-SCREW Removable Terminal Block","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-RTB18-SCREW\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a specialized 18-pin removable terminal block (RTB) designed for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCompact 5000 I\/O\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCompactLogix 5380\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eplatform. It serves as the physical interface between the field-side wiring and the I\/O modules or controllers. The \"SCREW\" designation indicates that this model utilizes traditional screw-clamp terminations, providing a high-torque, secure connection for industrial environments where vibration resistance and wiring reliability are paramount.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e5069-RTB18-SCREW\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAllen-Bradley (Rockwell Automation)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal Pins\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e18\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTermination Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eScrew Clamp\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTorque Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.4 N·m (3.5 lb·in)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWire Size (Solid)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e22–12 AWG\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWire Size (Stranded)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e22–14 AWG\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e250V (Continuous)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 A per pin\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eCore Functionalities\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003e1. High-Density Connectivity\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe 18-pin layout is designed to match the high-density architecture of the 5069 I\/O series. It allows for the termination of multiple signal and return wires on a single block, maximizing cabinet space.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e2. Removable Architecture (RIUP)\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eA key feature of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-RTB18-SCREW\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis its support for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRemoval and Insertion Under Power (RIUP)\u003c\/strong\u003e. This allows maintenance personnel to replace a faulty I\/O module without disconnecting the field wiring, significantly reducing Mean Time to Repair (MTTR) and preventing wiring errors during hardware swaps.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e3. Secure Screw Termination\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eUnlike the \"SPRING\" (push-in) variants, the screw-clamp mechanism ensures a gas-tight connection that is highly resistant to mechanical loosening. This makes the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-RTB18-SCREW\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ethe preferred choice for applications in heavy manufacturing, mining, and oil \u0026amp; gas where equipment is subject to constant physical stress.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical FAQs\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 5069-RTB18-SCREW compatible with all 5069 modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt is compatible with many 5069 discrete and analog modules, but you must verify the pin count. Some specialized modules require 14-pin blocks (\u003cstrong\u003e5069-RTB14\u003c\/strong\u003e). Always check the specific I\/O module's technical data sheet to ensure 18 pins are supported.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I mix screw and spring terminal blocks in the same rack?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The choice of RTB is module-specific. You can use a screw-type RTB for an analog input module and a spring-type RTB for a discrete output module within the same\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCompactLogix 5380\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esystem.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo I need a special tool for wiring?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA standard small flat-head screwdriver (typically 3.5 mm) is required to tighten the clamps to the recommended torque of 0.4 N·m.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering \u0026amp; Installation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTorque Compliance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOver-tightening can damage the internal clamp, while under-tightening can lead to intermittent signals or arcing. Using a calibrated torque screwdriver is recommended for safety-critical circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWire Preparation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStrip the wire insulation back approximately 10–12 mm. For stranded wire, the use of ferrules is highly recommended to prevent fraying and ensure a clean insertion into the clamp.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eKeying:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 5069 series supports mechanical keying. It is best practice to use the keying tabs to prevent an RTB wired for high voltage from being accidentally inserted into a low-voltage analog module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering Advantages\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-RTB18-SCREW\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis favored for its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRobustness and Versatility\u003c\/strong\u003e. In global industrial markets, screw terminals are often mandated by local electrical standards for their visibility—an engineer can visually verify that a screw is tightened, providing an extra layer of confidence during commissioning. By isolating the wiring from the electronic module, Rockwell has created a modular system that simplifies both the initial build and long-term maintenance of the control cabinet.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":53084005564779,"sku":"5069-RTB18-SCREW","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/Allen-Bradley5069-RTB18-SCREW.png?v=1775993709"},{"product_id":"allen-bradley-5069-l310erms2-compact-guardlogix-5380-sil-2-controller","title":"Allen-Bradley 5069-L310ERMS2 Compact GuardLogix 5380 SIL 2 Controller","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-L310ERMS2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance safety controller from the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCompact GuardLogix 5380\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efamily. It provides integrated control for both standard and safety-related industrial applications, achieving safety ratings up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSIL 2 \/ PLd (Category 3)\u003c\/strong\u003e. This controller is designed for machine builders who require a single, compact unit to manage complex logic, high-speed I\/O, and motion, while simultaneously ensuring functional safety for personnel and equipment.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e5069-L310ERMS2\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAllen-Bradley (Rockwell Automation)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStandard Memory\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 MB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSafety Memory\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 MB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSafety Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSIL 2 \/ PLd (Category 3)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIntegrated Motion\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to \u003cstrong\u003e4 axes\u003c\/strong\u003e (CIP Motion over EtherNet\/IP)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEthernet Nodes\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupports up to \u003cstrong\u003e24 nodes\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLocal I\/O Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 8 local 5069 modules\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProgramming\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStudio 5000 Logix Designer (v31 or later)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eCore Capabilities\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003e1. Integrated Safety \u0026amp; Standard Control\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-L310ERMS2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eeliminates the need for a separate safety PLC. It uses a \"1oo2\" (one out of two) internal architecture to monitor and execute safety functions. In Studio 5000, safety logic is kept in a dedicated \"Safety Task\" with restricted access, ensuring that standard code modifications do not inadvertently affect safety signatures.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e2. Integrated Motion on EtherNet\/IP\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe \"M\" in the catalog number signifies integrated motion support. It can coordinate up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4 axes of CIP Motion\u003c\/strong\u003e, allowing for synchronized control of Kinetix servo drives. Crucially, this includes\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCIP Safety over EtherNet\/IP\u003c\/strong\u003e, enabling safe speed, safe direction, and safe torque off (STO) functions to be managed over the same network cable as the standard control data.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e3. High-Speed Performance \u0026amp; Dual Gigabit Ethernet\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDual-IP Mode:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAllows for the physical separation of safety\/I\/O traffic from the higher-level enterprise network, which is vital for maintaining safety determinism and cybersecurity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDLR Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports Device Level Ring topologies to ensure that a single cable failure does not drop the safety connection, preventing nuisance trips.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical FAQs\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between the 5069-L310ERM and the 5069-L310ERMS2?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eL310ERM\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a standard controller with motion support. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eL310ERMS2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eadds a dedicated 0.5 MB safety memory partition and the internal diagnostics required to be certified for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSIL 2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esafety applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use standard 5069 I\/O modules with this controller?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. You can mix standard 5069 I\/O modules for non-safety tasks and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-IB8S \/ OBV8S\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esafety modules for safety tasks in the same local rack or on the same remote EtherNet\/IP network.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this controller require a safety partner module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. Unlike the older 1756 GuardLogix systems that required a primary and a safety partner, the Compact GuardLogix 5380 series (like the L310ERMS2) is a self-contained safety controller.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering \u0026amp; Installation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSafety Signatures:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOnce the safety logic is validated, the controller generates a unique safety signature. Any change to the safety code changes this signature, providing a clear audit trail for regulatory compliance (e.g., OSHA or CE).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Architecture:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eLike other 5069 units, it requires\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMOD Power\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(for logic) and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSA Power\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(for field-side I\/O power). Use high-quality DC power supplies to ensure the safety bus remains stable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Considerations:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe controller is designed for an operating temperature range of 0 to\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e60°C\u003c\/span\u003e. In safety applications, ensure that cabinet cooling is adequate, as the safety processor performs intense internal self-diagnostics that generate additional heat.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":53084049211755,"sku":"5069-L310ERMS2","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/5069-L310ERMS2_2.png?v=1775994732"},{"product_id":"allen-bradley-5069-ib16-compact-5000-digital-input-module","title":"Allen-Bradley 5069-IB16 Compact 5000 Digital Input Module","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-IB16\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density digital DC input module from the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley Compact 5000 I\/O\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efamily. It is designed to interface with the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCompactLogix 5380\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eControlLogix 5580\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(via remote EtherNet\/IP) controllers. Featuring 16 sinking inputs, this module is optimized for high-speed industrial applications where fast response times and precise signal detection are critical for machine performance.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e5069-IB16\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAllen-Bradley (Rockwell Automation)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Inputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 (Sinking)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVoltage Category\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12\/24V DC Sink\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Voltage Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10–32V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOn-State Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10V DC (Min)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOn-State Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 mA (Min)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Filter Time\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 ms to 30000 ms (Configurable)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Power (MOD)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e75 mA @ 18–32V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSensor\/Actuator Power (SA)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 mA @ 18–32V DC (plus field load)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eCore Capabilities\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003e1. High-Speed Processing\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eAs part of the Compact 5000 I\/O platform, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-IB16\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides significantly faster I\/O-to-backplane communication speeds compared to older 1769 or 1734 platforms. This ensures that the controller receives input state changes with minimal latency, improving the accuracy of high-speed sensors and registration marks.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e2. Sinking Input Design\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe module uses a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSinking\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003earchitecture, meaning it provides a path to the negative common for the connected device. This is the standard interface for \"Sourcing\" (PNP) field sensors.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e3. Extensive Diagnostics\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe 5069-IB16 features advanced diagnostic capabilities. Through Studio 5000, engineers can monitor:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Health:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStatus of the backplane connection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSA Power Status:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDetection of whether field-side power is present.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput State LEDs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIndividual green status indicators for each of the 16 channels, located on the front of the module for immediate physical troubleshooting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical FAQs\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhich Removable Terminal Block (RTB) does this module use?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 5069-IB16 is compatible with the 18-pin\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-RTB18-SCREW\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(screw-clamp) or\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-RTB18-SPRING\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(push-in style) terminal blocks. Note that RTBs are typically sold separately from the I\/O module.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module support RIUP?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Like other Compact 5000 I\/O modules, it supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRemoval and Insertion Under Power (RIUP)\u003c\/strong\u003e, allowing you to replace the module without shutting down the entire system or disconnecting field wiring.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the \"SA Power\" requirement?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module requires\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSensor\/Actuator (SA) Power\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto be fed through the controller or the field potential distributor. This power is used to provide the voltage for the inputs and the field-side circuitry.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering \u0026amp; Installation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring Practice:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUse shielded cable for inputs that are subjected to high electromagnetic interference (EMI). Ensure that the SA power common is correctly tied to the sensor common to establish a complete circuit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFilter Settings:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAdjust the digital filter settings in Studio 5000 to eliminate \"contact bounce\" from mechanical limit switches. For high-speed proximity sensors, set the filter time to the minimum (0 ms) to capture rapid pulses.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen mounting 16-point modules side-by-side, ensure the enclosure has adequate ventilation. The 5069 series utilizes passive convection cooling and requires at least 50mm of clearance above and below the rack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering Advantages\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-IB16\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis favored for its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEfficiency and Reliability\u003c\/strong\u003e. By providing 16 points in a very slim profile, it allows for high-density I\/O configurations in small control cabinets. Its deterministic performance makes it the standard choice for modern Allen-Bradley architectures where the goal is to synchronize high-speed I\/O with CIP Motion or complex safety logic.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":53084451799403,"sku":"5069-IB16","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/5069-IB16_2.png?v=1775995151"},{"product_id":"allen-bradley-5069-l310er-compactlogix-5380-controller","title":"Allen-Bradley 5069-L310ER CompactLogix 5380 Controller","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-L310ER\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance industrial controller from the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCompactLogix 5380\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efamily. It is designed to function as the \"brain\" of modern mid-sized automation systems, providing the high-speed processing and data capacity required for Industrial IoT (IIoT) applications. While it shares the same processing architecture as the motion-capable \"ERM\" models, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eL310ER\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis optimized for discrete and process control where integrated servo motion is not required.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e5069-L310ER\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAllen-Bradley (Rockwell Automation)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eUser Memory\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 MB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEthernet Nodes\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupports up to \u003cstrong\u003e24 Ethernet\/IP nodes\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLocal I\/O Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 8 local 5069 Compact I\/O modules\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Ports\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 Ethernet (Gigabit) \/ 1 USB 2.0 (Programming)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Architecture\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDual-input (MOD and SA power)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProgramming\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStudio 5000 Logix Designer (v28 or later)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eCore Capabilities\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003e1. High-Speed Logic Execution\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe 5380 series features a dedicated high-speed backplane that significantly increases I\/O scan rates compared to the older 1769 series. With 1 MB of memory, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-L310ER\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecan handle complex logical operations, arithmetic, and data string manipulations with extremely low latency.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e2. Advanced Networking Options\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe controller includes dual 1-Gbps Ethernet ports that offer two primary configuration modes:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDual-IP Mode:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis allows you to separate machine-level network traffic (sensors\/drives) from the plant-wide enterprise network, enhancing security and preventing network congestion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDevice Level Ring (DLR):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIn this mode, the ports provide network resiliency; if a single cable in the ring is damaged, communication continues uninterrupted.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003e3. Compact 5000 I\/O Integration\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe controller acts as the master for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069 Compact I\/O\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eplatform. This platform is known for its high-density design and advanced diagnostics, allowing for more I\/O points in a smaller cabinet footprint.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical FAQs\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between 5069-L310ER and 5069-L310ERM?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \"M\" in the ERM version stands for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMotion\u003c\/strong\u003e. The L310ERM supports up to 4 axes of Integrated CIP Motion (servo control). The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eL310ER\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis for standard applications and does not support coordinated servo motion over EtherNet\/IP.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this controller require a battery?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The CompactLogix 5380 series uses an internal energy storage module (capacitors) to back up the user program to non-volatile memory during a power failure. You do not need to replace or maintain lithium batteries.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat power terminal block do I need?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe controller requires a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-RTB22-SCREW\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-RTB22-SPRING\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eterminal block to connect the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMOD\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Module) and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Sensor\/Actuator) power feeds.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering \u0026amp; Installation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Partitioning:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure you wire both MOD power (for the CPU) and SA power (for the I\/O field side). Even if the CPU is running, your local I\/O modules will not function without a valid SA power feed.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 5380 series contains a high-speed processor that generates heat. Always mount the unit horizontally on a DIN rail and maintain at least\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e50 mm (2 in.)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eof clearance above and below for passive cooling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFirmware Updates:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAlways check the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eProduct Compatibility and Download Center (PCDC)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor the latest firmware. This controller often requires a firmware flash out of the box before it can be used with your specific version of Studio 5000.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering Advantages\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-L310ER\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis the \"sweet spot\" for engineers who need more than the entry-level 0.6 MB memory but don't want to pay the premium for motion axes they won't use. Its 24-node capacity makes it ideal for integrating multiple remote I\/O racks, PowerFlex drives, and HMI panels into a single, cohesive control architecture.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":53084604334443,"sku":"5069-L310ER","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/5069-L310ER.png?v=1775995917"},{"product_id":"allen-bradley-5069-l320er-compactlogix-5380-controller","title":"Allen-Bradley 5069-L320ER CompactLogix 5380 Controller","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-L320ER\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance industrial controller within the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCompactLogix 5380\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efamily. It is designed for mid-to-large scale automation tasks that require significant memory for data-heavy applications and complex logic. While it shares the high-speed processing architecture of the \"ERM\" motion models, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eL320ER\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis optimized for discrete and process control environments where integrated servo motion control is not required, offering a cost-effective solution for high-node-count systems.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e5069-L320ER\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAllen-Bradley (Rockwell Automation)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eUser Memory\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 MB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEthernet Nodes\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupports up to \u003cstrong\u003e40 Ethernet\/IP nodes\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLocal I\/O Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 16 local 5069 Compact I\/O modules\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Ports\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 Ethernet (Gigabit) \/ 1 USB 2.0 (Programming)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNon-volatile Memory\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 GB (via 1784-SD2 card)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProgramming\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStudio 5000 Logix Designer (v28 or later)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eCore Capabilities\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003e1. Expanded Memory \u0026amp; Node Capacity\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eWith\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e2 MB of user memory\u003c\/strong\u003e, the 5069-L320ER provides double the capacity of the L310 series. This makes it ideal for applications involving extensive recipes, advanced alarm handling, or large data-logging buffers. Its support for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e40 Ethernet\/IP nodes\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eallows for the integration of a vast array of remote I\/O, PowerFlex drives, and HMI panels.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e2. High-Performance Backplane\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eAs part of the 5380 series, this controller utilizes the high-speed 5069 backplane. This architecture provides significantly faster I\/O scan times and improved determinism compared to older 1769-series controllers, allowing for more precise control over high-speed machinery.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e3. Advanced Gigabit Networking\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe dual 1-Gbps Ethernet ports can be configured in two primary ways:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDual-IP Mode:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProvides physical and logical network segmentation, allowing you to keep machine-level I\/O traffic isolated from the plant’s enterprise network for better security and performance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDevice Level Ring (DLR):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsures network resiliency. If a single point of failure occurs in the Ethernet ring, the system maintains communication, preventing unnecessary downtime.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical FAQs\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between 5069-L320ER and 5069-L320ERM?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \"M\" in the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eERM\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eversion stands for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMotion\u003c\/strong\u003e. The L320ERM supports up to 8 axes of Integrated CIP Motion (servo control). The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eL320ER\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis for standard logic applications and does not support coordinated servo motion over EtherNet\/IP.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow is power distributed to this controller?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 5069 platform uses a split-power architecture:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMOD Power:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePowers the internal controller logic and circuitry.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSA Power (Sensor\/Actuator):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProvides power to the field-side circuitry of the connected I\/O modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this controller require a battery?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The CompactLogix 5380 series uses internal capacitors to back up the user program to non-volatile memory during a power failure, eliminating the need for lithium battery maintenance.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering \u0026amp; Installation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting \u0026amp; Cooling:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe controller must be mounted horizontally on a standard 35 mm DIN rail. Because the high-speed processor generates heat, ensure at least\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e50 mm (2 in.)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eof clearance above and below the unit for convection cooling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTerminal Blocks:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe controller requires a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-RTB22-SCREW\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-RTB22-SPRING\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eterminal block to connect the MOD and SA power feeds. These are typically sold separately.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNetwork Planning:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen utilizing the 40-node capacity, ensure your network switch infrastructure can handle the 1-Gbps throughput to take full advantage of the controller's speed.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering Advantages\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-L320ER\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis the \"powerhouse\" choice for standard control. It is frequently selected for complex process skids or assembly lines where the logic complexity is high, but the mechanical movements are handled by standard AC drives or pneumatic actuators rather than synchronized servos. Its ability to manage 16 local I\/O modules also makes it excellent for high-density local control without needing remote racks.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":53084746482027,"sku":"5069-L320ER","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/5069-L320ER.png?v=1775996325"},{"product_id":"allen-bradley-5069-ob16-compact-5000-digital-output-module","title":"Allen-Bradley 5069-OB16 Compact 5000 Digital Output Module","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-OB16\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density digital DC output module from the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley Compact 5000 I\/O\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eseries. It features 16 sourcing outputs and is designed for use with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCompactLogix 5380\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eControlLogix 5580\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(via a 5069-AENTR) controllers. This module is engineered for high-speed switching of industrial actuators, such as solenoid valves, motor starters, and indicator lights, providing a fast and deterministic interface for modern automated systems.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e5069-OB16\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAllen-Bradley (Rockwell Automation)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Outputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 (Sourcing)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVoltage Category\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24V DC Source\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Voltage Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10–32V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Current Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 A per channel (8 A max per module)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSurge Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 A for 10 ms per channel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Power (MOD)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e75 mA @ 18–32V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSensor\/Actuator Power (SA)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 mA @ 18–32V DC (plus field load)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eCore Capabilities\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003e1. Sourcing Output Architecture\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-OB16\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003euses a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSourcing\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesign, meaning the module provides the positive voltage (+24V DC) to the load. The other side of the load is typically connected to the common (ground). This is the most common output configuration for driving industrial components in a PNP-compatible circuit.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e2. High-Speed Performance\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003ePart of the Compact 5000 platform, this module benefits from a high-speed system backplane that ensures output commands from the controller are executed with minimal latency. This is essential for applications requiring precise timing, such as high-speed sorting or synchronized packaging movements.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e3. Advanced Module Diagnostics\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe 5069-OB16 provides real-time diagnostic information to the controller, which can be viewed in Studio 5000:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSA Power Monitoring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDetects if the field-side power supply is missing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Status LEDs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFeatures individual green status LEDs for each of the 16 channels, allowing for rapid visual troubleshooting on the factory floor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eElectronic Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIncludes built-in protection against overcurrent and short-circuit conditions on a per-module basis.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical FAQs\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhich Removable Terminal Block (RTB) is required?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module is compatible with the 18-pin\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-RTB18-SCREW\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(screw-clamp) or\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-RTB18-SPRING\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(push-in) terminal blocks. Note that these are typically ordered separately from the module itself.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module support RIUP?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. It supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRemoval and Insertion Under Power (RIUP)\u003c\/strong\u003e, which allows maintenance personnel to swap out a module without powering down the entire chassis or disconnecting the field wiring.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the \"SA Power\" requirement?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSensor\/Actuator (SA) Power\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emust be supplied to the module through the controller or a field potential distributor. This power is used to energize the output circuits and the physical devices (solenoids, etc.) connected to them.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering \u0026amp; Installation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring Practice:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFor inductive loads (like solenoids or relays), it is standard practice to use an external surge suppressor (flyback diode) across the load to protect the module’s internal transistors from back-EMF spikes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Considerations:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen switching high-current loads across all 16 channels simultaneously, ensure the cabinet has sufficient ventilation. Maintain at least\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e50 mm (2 in.)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eof clearance above and below the module for convection cooling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCommon Tie-In:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure that the SA Power common is correctly tied to the load common to complete the electrical circuit for the sourcing outputs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering Advantages\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-OB16\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis highly valued for its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHigh Density and Reliability\u003c\/strong\u003e. By providing 16 points in a slim 22mm wide module, it allows for significant I\/O expansion in space-constrained control cabinets. Its deterministic integration with the Logix 5000 environment ensures that even complex, multi-output sequences are executed with the precision required for high-performance IIoT-ready machinery.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":53084747956587,"sku":"5069-OB16","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/5069-OB16.png?v=1775996986"},{"product_id":"allen-bradley-5069-rtb64-screw-removable-terminal-block","title":"Allen-Bradley 5069-RTB64-SCREW Removable Terminal Block","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-RTB64-SCREW\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density, 64-pin removable terminal block (RTB) designed specifically for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCompact 5000 I\/O\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eplatform. This accessory is required for high-point-count modules, such as the 32-point digital input or output modules (e.g., 5069-IB32 or 5069-OB32), where standard 18-pin blocks do not provide enough termination points. The \"SCREW\" version features traditional screw-clamp connections, offering a secure and vibration-resistant interface for complex industrial wiring.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e5069-RTB64-SCREW\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eAllen-Bradley (Rockwell Automation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Pins\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTermination Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrew Clamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWire Size (Solid\/Stranded)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22–16 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTorque Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.22–0.25 N·m (2.0–2.2 lb·in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32V DC Max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Modules\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5069-IB32, 5069-OB32, 5069-IY4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eCore Functionalities\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003e1. High-Density Termination\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-RTB64-SCREW\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis engineered to manage the significant wiring requirements of 32-point modules within a slim 22mm module width. By utilizing a multi-tier screw-clamp arrangement, it allows 64 individual wires (inputs\/outputs and commons) to be landed in a very small physical footprint.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e2. Support for RIUP\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eLike all RTBs in the Compact 5000 series, this block supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRemoval and Insertion Under Power (RIUP)\u003c\/strong\u003e. This allows maintenance teams to replace the electronic I\/O module without disturbing the field wiring, significantly reducing downtime and eliminate the risk of cross-wiring during replacement.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e3. Mechanical Security\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe screw-clamp design is particularly effective in environments subject to constant mechanical vibration. Once tightened to the correct torque, the clamps provide a gas-tight seal that prevents oxidation and intermittent connections over the life of the control system.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical FAQs\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this RTB with a standard 16-point module like the 5069-IB16?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-RTB64-SCREW\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis physically larger and has a different pin alignment than the 18-pin blocks used for 16-point modules. It is strictly for 32-point modules or specialized analog modules designed for 64-pin interfaces.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it come with the I\/O module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eGenerally, no. In the Allen-Bradley Compact 5000 series, Removable Terminal Blocks are sold as separate catalog items. This allows users to choose between\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSCREW\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(5069-RTB64-SCREW) or\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSPRING\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(5069-RTB64-SPRING) push-in style connectors based on their preference.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I manage such a large bundle of wires?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBecause 64 wires can be bulky, it is recommended to use the integrated cable tie-down points on the module housing. Using ferrules is also highly recommended to keep the wire ends neat and ensure they fit into the high-density spacing of the RTB.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering \u0026amp; Installation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTorque Sensitivity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBecause of the high density, the screws on the 64-pin block are smaller than those on the 18-pin blocks. It is critical to use a precision screwdriver and stay within the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0.22–0.25 N·m\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003etorque range to avoid stripping the threads.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring Sequence:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIt is best practice to wire the bottom tier first and work your way up to the top tier. This prevents previously landed wires from obstructing access to the lower terminal screws.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eKeying and Coding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUse the plastic keying tabs provided with the module to ensure the RTB can only be plugged into the correct type of module, preventing potential damage from mismatched voltage levels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering Advantages\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-RTB64-SCREW\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis the primary enabler of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSpace-Optimized I\/O\u003c\/strong\u003e. In modern control cabinets where DIN rail space is at a premium, being able to land 32 points of I\/O in a single 22mm slot is a major advantage. By using the screw-clamp version, engineers ensure that even these high-density connections remain reliable under the harsh thermal and mechanical conditions of a factory floor or a moving skid.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":53084749169003,"sku":"5069-RTB64-SCREW","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/5069-RTB64-SCREW_2.png?v=1775997651"},{"product_id":"5069-l306er-allen-bradley-compact-guardlogix-5380-safety-controller","title":"5069-L306ER Allen-Bradley Compact GuardLogix 5380 Safety Controller","description":"\u003ch3\u003eCritical Product Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-L306ER (5069L306ER)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCompact GuardLogix 5380\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esafety controller engineered to provide integrated motion and safety control within a single hardware platform. This unit is specifically designed for complex industrial applications requiring\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSIL 3\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePLe (Category 4)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esafety ratings. By utilizing a dual-processor architecture, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-L306ER\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eexecutes safety logic and standard logic simultaneously, significantly reducing the hardware footprint and simplifying system integration. Ideal for high-speed manufacturing, automotive assembly lines, and heavy machinery, this controller optimizes system reaction times and minimizes unplanned downtime through advanced diagnostics and high-speed\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEtherNet\/IP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econnectivity. It provides a scalable solution for engineers looking to balance rigorous safety standards with maximum operational efficiency.\u003c\/p\u003e\n\u003ch3\u003eArchitectural Configuration and Logic\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 5069-L306ER\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eutilizes the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eLogix\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econtrol engine to deliver high-speed processing and increased throughput. This controller is characterized by its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0.6 MB\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003estandard user memory and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0.3 MB\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ededicated safety memory. The dual-port design supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e16 EtherNet\/IP nodes\u003c\/strong\u003e, allowing for flexible network topologies including\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDevice Level Ring (DLR)\u003c\/strong\u003e, Linear, and Star configurations.\u003c\/p\u003e\n\u003cp\u003eAs part of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5380 series\u003c\/strong\u003e, it operates using\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eStudio 5000 Logix Designer\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esoftware (Version 31 or later). The hardware design isolates the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eModule (MOD) Power\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(logic side) from the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSensor\/Actuator (SA) Power\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(field side), preventing electrical noise from impacting the central processing unit and ensuring stable execution of safety instructions in electrically noisy environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e5069-L306ER\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAllen-Bradley\u003c\/strong\u003e (Rockwell Automation)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCompact GuardLogix 5380\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSafety Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSIL 3 \/ PLe \/ Cat. 4\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStandard Memory\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e0.6 MB\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSafety Memory\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e0.3 MB\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEtherNet\/IP Nodes\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e16 Nodes\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLocal I\/O Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to \u003cstrong\u003e8 Modules\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e0 to 60 deg C\u003c\/strong\u003e (32 to 140 deg F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-40 to 85 deg C\u003c\/strong\u003e (-40 to 185 deg F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage (MOD)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e18 to 32 VDC\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e143.97 x 98.10 x 136.81 mm\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApproximately \u003cstrong\u003e0.77 kg\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eUSA\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eSafety Technical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the 5069-L306ER achieve SIL 3 safety without an external safety partner?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-L306ER\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures a built-in 1oo2 (one out of two) processor architecture. The internal safety task is executed in a redundant manner, and the controller performs continuous self-diagnostics to ensure safety integrity. This allows the unit to meet\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSIL 3\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePLe\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erequirements in a single, compact module without the need for a separate safety partner module.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this controller be used with standard 5069 Compact I\/O modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-L306ER\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports both standard and safety-rated\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069 Compact I\/O\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodules. However, to maintain the safety integrity of a specific safety loop, you must utilize\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-IB8S\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-OBV8S\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esafety I\/O modules for the safety-related inputs and outputs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the function of the SD card slot on this unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe controller includes a slot for an industrial-grade\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSecure Digital (SD)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecard (1 GB standard). This is used for non-volatile storage of the user program, firmware, and safety configurations. It allows for fast \"device replacement\" without requiring a PC to reload the logic, which is critical for reducing Mean Time to Repair (MTTR).\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003ePrecision Installation \u0026amp; Thermal Management\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Isolation Strategy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure that\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMOD Power\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSA Power\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eare sourced from separate power supplies if your application requires isolation between logic and field-side devices. Use a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eClass 2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSELV\/PELV\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erated power supply to comply with regulatory standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding \u0026amp; Shielding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo mitigate electromagnetic interference (EMI), use\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDIN rail\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003egrounding and ensure all communication cables are shielded. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-L306ER\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emust be mounted on a grounded, corrosion-resistant DIN rail.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eClearance and Airflow:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMaintain at least\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e50 mm\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(2 inches) of clearance on all sides of the controller. This ensures adequate convection cooling and prevents thermal throttling when operating at the upper limit of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e60 deg C\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003etemperature range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePerformance \u0026amp; Durability Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Safety Motion:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis controller supports up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e2 axes\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eof integrated motion over EtherNet\/IP, allowing safety instructions (like Safe Torque Off) to be executed directly over the network, eliminating hard-wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Resilience:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBuilt with industrial-grade components, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-L306ER\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis rated for high-vibration environments and features a conformal coating option for protection against chemical contaminants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnhanced Cybersecurity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe hardware utilizes\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edigitally signed firmware\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand controller-based change detection, providing a robust layer of defense against unauthorized code injection or tampering in mission-critical infrastructure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":53084783870315,"sku":"5069-L306ER","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/5069-L306ER.png?v=1775998108"},{"product_id":"allen-bradley-5069-l3100erm-compactlogix-5380-motion-controller","title":"Allen-Bradley 5069-L3100ERM CompactLogix 5380 Motion Controller","description":"\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 5069-L3100ERM\u003c\/strong\u003e is a CompactLogix 5380 motion controller designed for industrial automation and integrated motion applications. It provides 10 MB of user memory and supports Integrated Motion over EtherNet\/IP.\u003c\/p\u003e\n\u003cp\u003eThe controller provides two Ethernet ports for EtherNet\/IP communication and a USB programming port. Its Ethernet interfaces can operate in Dual-IP or Linear\/DLR mode.\u003c\/p\u003e\n\u003cp\u003eThe 5069-L3100ERM supports up to 31 local Compact 5000 I\/O modules with applicable Logix Designer versions. It supports up to 180 EtherNet\/IP nodes and 32 position-loop-configured Integrated Motion drive axes.\u003c\/p\u003e\n\u003cp\u003eThe controller belongs to the Logix 5000 controller family and mounts on a DIN rail. It can monitor and control local I\/O, remote I\/O, and EtherNet\/IP-connected devices.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAllen-Bradley 5069-L3100ERM CompactLogix 5380 motion controller\u003c\/strong\u003e with Integrated Motion over EtherNet\/IP.\u003c\/li\u003e\n\u003cli\u003e10 MB user memory for controller applications.\u003c\/li\u003e\n\u003cli\u003eSupports up to 31 local I\/O modules with applicable Studio 5000 Logix Designer versions.\u003c\/li\u003e\n\u003cli\u003eSupports up to 180 EtherNet\/IP nodes with Logix Designer version 31 or later.\u003c\/li\u003e\n\u003cli\u003eSupports up to 32 position-loop-configured Integrated Motion over EtherNet\/IP drive axes.\u003c\/li\u003e\n\u003cli\u003eTwo Ethernet ports with 10 Mbps, 100 Mbps, and 1 Gbps operation.\u003c\/li\u003e\n\u003cli\u003eEthernet communication operates in full-duplex mode.\u003c\/li\u003e\n\u003cli\u003eDual-IP and Linear\/DLR operating modes are supported.\u003c\/li\u003e\n\u003cli\u003eSupports DLR, star, and linear EtherNet\/IP network topologies.\u003c\/li\u003e\n\u003cli\u003eUSB 2.0 Type B port supports programming, configuration, firmware updates, and online edits.\u003c\/li\u003e\n\u003cli\u003eSupports continuous, periodic, and event controller tasks.\u003c\/li\u003e\n\u003cli\u003eSupports Ladder Diagram, Structured Text, Function Block Diagram, and Sequential Function Chart programming languages.\u003c\/li\u003e\n\u003cli\u003eSupports optional SD-card nonvolatile memory.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMachine automation requiring coordinated motion control.\u003c\/li\u003e\n\u003cli\u003eIntegrated Motion over EtherNet\/IP applications.\u003c\/li\u003e\n\u003cli\u003eStandalone industrial control systems.\u003c\/li\u003e\n\u003cli\u003eEtherNet\/IP-connected machine control architectures.\u003c\/li\u003e\n\u003cli\u003eLocal and remote Compact 5000 I\/O control.\u003c\/li\u003e\n\u003cli\u003eDistributed automation systems using DLR, star, or linear Ethernet topologies.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley \/ Rockwell Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003e5069-L3100ERM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eController Family\u003c\/td\u003e\n\u003ctd\u003eCompactLogix 5380\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eController Type\u003c\/td\u003e\n\u003ctd\u003eMotion Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser Memory\u003c\/td\u003e\n\u003ctd\u003e10 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor\u003c\/td\u003e\n\u003ctd\u003eQuad Core\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal I\/O Modules, Maximum\u003c\/td\u003e\n\u003ctd\u003e31 with Studio 5000 Logix Designer version 30.00.00 or later\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEtherNet\/IP Nodes, Maximum\u003c\/td\u003e\n\u003ctd\u003e180 with Logix Designer version 31 or later\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated Motion Drive Axes\u003c\/td\u003e\n\u003ctd\u003e32 maximum, position-loop configured\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eController Tasks\u003c\/td\u003e\n\u003ctd\u003e32 tasks; continuous, periodic, and event\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrograms per Task\u003c\/td\u003e\n\u003ctd\u003e1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eCommunication\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Industrial Network\u003c\/td\u003e\n\u003ctd\u003eEtherNet\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Ports\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Data Rates\u003c\/td\u003e\n\u003ctd\u003e10 Mbps, 100 Mbps, 1 Gbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Duplex\u003c\/td\u003e\n\u003ctd\u003eFull-duplex only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEtherNet\/IP Modes\u003c\/td\u003e\n\u003ctd\u003eDual-IP mode; Linear\/DLR mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Network Topologies\u003c\/td\u003e\n\u003ctd\u003eDLR, star, linear\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB Interface\u003c\/td\u003e\n\u003ctd\u003eUSB 2.0 Type B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB Data Rate\u003c\/td\u003e\n\u003ctd\u003e12 Mbps, full speed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB Functions\u003c\/td\u003e\n\u003ctd\u003eProgramming, configuration, firmware update, and online edits only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eElectrical\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMOD Power Voltage Range\u003c\/td\u003e\n\u003ctd\u003e18…32V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMOD Power Current, Maximum\u003c\/td\u003e\n\u003ctd\u003e450 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMOD Power Inrush\u003c\/td\u003e\n\u003ctd\u003e850 mA for 125 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMOD Power Current Rating, Maximum\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSA Power Voltage Range\u003c\/td\u003e\n\u003ctd\u003e0…32V DC; 0…240V AC, 47…63 Hz; EX 125V AC maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSA Power Current Rating, Maximum\u003c\/td\u003e\n\u003ctd\u003e10 A, AC or DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation, Maximum\u003c\/td\u003e\n\u003ctd\u003e8.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal Dissipation, Maximum\u003c\/td\u003e\n\u003ctd\u003e29 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Cycles\u003c\/td\u003e\n\u003ctd\u003e80,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eMechanical\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN rail, horizontal mounting only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible DIN Rail\u003c\/td\u003e\n\u003ctd\u003eEN 50022, 35 x 7.5 mm zinc-plated chromate steel DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApproximate Weight\u003c\/td\u003e\n\u003ctd\u003e0.768 kg (1.693 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eNone, open-style\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eEnvironmental\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0°C \u0026lt; Ta \u0026lt; +60°C (+32°F \u0026lt; Ta \u0026lt; +140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNonoperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40…+85°C (-40…+185°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Surrounding Air Temperature\u003c\/td\u003e\n\u003ctd\u003e60°C (140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5…95%, noncondensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Vibration\u003c\/td\u003e\n\u003ctd\u003e5 g at 10…500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Shock\u003c\/td\u003e\n\u003ctd\u003e30 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNonoperating Shock\u003c\/td\u003e\n\u003ctd\u003e50 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eProgramming\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLadder Diagram\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStructured Text\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction Block Diagram\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSequential Function Chart\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Port 1\u003c\/td\u003e\n\u003ctd\u003eEtherNet\/IP communication; supports Dual-IP or Linear\/DLR operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Port 2\u003c\/td\u003e\n\u003ctd\u003eEtherNet\/IP communication; supports Dual-IP or Linear\/DLR operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB 2.0 Type B\u003c\/td\u003e\n\u003ctd\u003eTemporary connection for programming, configuration, firmware updates, and online edits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMOD Power RTB\u003c\/td\u003e\n\u003ctd\u003eModule-side system power connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSA Power RTB\u003c\/td\u003e\n\u003ctd\u003eSensor\/actuator-side system power connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the controller horizontally on a compatible DIN rail.\u003c\/li\u003e\n\u003cli\u003eUse EN 50022, 35 x 7.5 mm compatible DIN rail.\u003c\/li\u003e\n\u003cli\u003eProvide MOD Power within the specified 18…32V DC range.\u003c\/li\u003e\n\u003cli\u003eSelect the appropriate separately ordered removable terminal block kit.\u003c\/li\u003e\n\u003cli\u003e5069-RTB64-SCREW provides screw-type MOD and SA power terminal blocks.\u003c\/li\u003e\n\u003cli\u003e5069-RTB64-SPRING provides spring-type MOD and SA power terminal blocks.\u003c\/li\u003e\n\u003cli\u003eUse Ethernet cabling and installation practices according to IEC 61918 and IEC 61784-5-2.\u003c\/li\u003e\n\u003cli\u003eConfigure unique IP addresses for both Ethernet ports when using Dual-IP mode.\u003c\/li\u003e\n\u003cli\u003eLinear\/DLR mode uses one IP address for the controller.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cp\u003eRockwell Automation technical data identifies the 5069-L3100ERM within the CompactLogix 5380 certification group. Applicable certifications include c-UL-us, CE, UKCA, RCM, ATEX, IECEx, CCC, EtherNet\/IP conformance, and CIP Security conformance. Certification applicability can depend on hardware revision and the markings on the specific product.\u003c\/p\u003e\n\u003cp\u003eThe CompactLogix 5380 controller family is also certified to IEC 62443-4-2:2019 for Embedded Devices up to Security Level Capability 1 (SL-C 1). The uploaded TÜV Rheinland revision list specifically includes the \u003cstrong\u003e5069-L3100ERM Series A\u003c\/strong\u003e with certified firmware revisions through V38.011.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":53722351534443,"sku":"5069-L3100ERM","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/1756-EN2TR_001_1200x1200_ce80b0c3-3504-4aae-a972-8d1ccf3f6fad.jpg?v=1786686563"},{"product_id":"allen-bradley-5069-l330erms2-compact-guardlogix-5380-sil2-safety-controller","title":"Allen-Bradley 5069-L330ERMS2 Compact GuardLogix 5380 SIL2 Safety Controller","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 5069-L330ERMS2\u003c\/strong\u003e is a Compact GuardLogix 5380 safety controller designed for high-performance machine control, integrated motion, and functional safety applications. Functioning as a dual-core processing unit within the CompactLogix platform, it supports standard control tasks while executing dedicated safety routines up to Safety Integrity Level 2 (SIL 2) and Performance Level d (PLd). The controller features 3.0 MB of standard user memory and 1.5 MB of safety user memory, providing a robust execution environment for complex ladder logic, structured text, function blocks, and motion commands.\u003c\/p\u003e\n\u003cp\u003eBuilt with dual embedded Ethernet ports, the \u003cstrong\u003e5069-L330ERMS2\u003c\/strong\u003e supports high-speed network topologies including Device Level Ring (DLR), Linear, and Star configurations. It provides native CIP Safety over EtherNet\/IP, enabling secure communication with distributed safety I\/O modules, drives, and field devices. Equipped with integrated motion capability, the unit can control up to 16 motion axes over an EtherNet\/IP network. The controller directly interfaces with up to 31 local Compact 5000 I\/O modules and manages up to 60 network nodes, serving as a scalable control hub for automated production lines and safety-critical machinery.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual-Memory Architecture:\u003c\/strong\u003e Equips 3.0 MB of standard memory and 1.5 MB of dedicated safety memory for high-integrity program execution.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunctional Safety Compliance:\u003c\/strong\u003e Achieves SIL 2 (IEC 61508) and PLd (ISO 13849-1) functional safety performance via dedicated safety tasks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Motion Control:\u003c\/strong\u003e Supports up to 16 axes of CIP Motion over EtherNet\/IP for synchronized servo and drive control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Network Topologies:\u003c\/strong\u003e Embedded dual Ethernet ports support Gigabit communication rates in DLR, Linear, and Star configurations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual-IP \u0026amp; Network Isolation:\u003c\/strong\u003e Supports Dual-IP mode to separate enterprise-level traffic from local machine-level device networks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocal Expansion Capability:\u003c\/strong\u003e Interfaces directly with up to 31 local Compact 5000 standard and safety I\/O modules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScalable Node Limit:\u003c\/strong\u003e Manages up to 60 EtherNet\/IP network nodes for remote I\/O, drives, and human-machine interfaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemovable Storage:\u003c\/strong\u003e Includes a 1784-SD2 Secure Digital card slot for non-volatile project backup, restore, and diagnostic logging.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety-Critical Machine Control:\u003c\/strong\u003e Safeguarding robotic cells, automated assembly lines, packaging machinery, and material handling systems requiring SIL 2 \/ PLd functional safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSynchronized Motion Systems:\u003c\/strong\u003e Controlling multi-axis servo drives, gantry systems, and indexing tables utilizing CIP Motion over EtherNet\/IP.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDistributed Industrial Networks:\u003c\/strong\u003e Interfacing central control systems with remote Compact 5000 I\/O, Guard I\/O, and POINT Guard I\/O across DLR networks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley \/ Rockwell Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eCompact GuardLogix 5380\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExact Model\u003c\/td\u003e\n\u003ctd\u003e5069-L330ERMS2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eCompact GuardLogix SIL2 Safety Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Memory\u003c\/td\u003e\n\u003ctd\u003e3.0 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Memory\u003c\/td\u003e\n\u003ctd\u003e1.5 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEtherNet\/IP Network Nodes\u003c\/td\u003e\n\u003ctd\u003e60 max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal I\/O Expansion\u003c\/td\u003e\n\u003ctd\u003e31 Compact 5000 I\/O modules max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated Motion Axes\u003c\/td\u003e\n\u003ctd\u003e16 axes max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eController Tasks\u003c\/td\u003e\n\u003ctd\u003e32 total tasks (31 standard tasks + 1 safety task)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrograms per Task\u003c\/td\u003e\n\u003ctd\u003e1000 max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-volatile Memory\u003c\/td\u003e\n\u003ctd\u003e1784-SD2 (1 GB) shipped with controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eElectrical \u0026amp; Power\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMOD Power Source Requirement\u003c\/td\u003e\n\u003ctd\u003e18...32V DC (SELV\/PELV rated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMOD Power Bus Current Limit\u003c\/td\u003e\n\u003ctd\u003e5 A max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSA Power Source Requirement\u003c\/td\u003e\n\u003ctd\u003e18...32V DC (SELV\/PELV rated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSA Power Bus Current Limit\u003c\/td\u003e\n\u003ctd\u003e10 A max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation at Full Load\u003c\/td\u003e\n\u003ctd\u003e9 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e4-character status display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eCommunication\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmbedded Communication Ports\u003c\/td\u003e\n\u003ctd\u003e2 x Ethernet (10\/100\/1000 Mbps RJ45), 1 x USB 2.0 Type B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Topologies\u003c\/td\u003e\n\u003ctd\u003eDevice Level Ring (DLR), Linear, Star\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEtherNet\/IP Modes\u003c\/td\u003e\n\u003ctd\u003eDual-IP mode, Linear\/DLR mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Protocols\u003c\/td\u003e\n\u003ctd\u003eEtherNet\/IP, CIP Safety, CIP Sync, Socket Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Port A1\u003c\/td\u003e\n\u003ctd\u003ePrimary network interface for DLR, Linear, or Device-level EtherNet\/IP connections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Port A2\u003c\/td\u003e\n\u003ctd\u003eSecondary network interface for Enterprise-level or dual-IP network separation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB Port\u003c\/td\u003e\n\u003ctd\u003eType B 2.0 full-speed port for local programming, firmware update, and diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMOD Power RTB\u003c\/td\u003e\n\u003ctd\u003eRemovable terminal block connection for 24V DC SELV\/PELV module power bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSA Power RTB\u003c\/td\u003e\n\u003ctd\u003eRemovable terminal block connection for 24V DC SELV\/PELV sensor\/actuator power bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSD Card Slot\u003c\/td\u003e\n\u003ctd\u003eHouses the 1784-SD2 card for firmware, project backup, and system diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Requirements:\u003c\/strong\u003e Install the controller in an IP54-rated (or equivalent) protective industrial enclosure accessible only with a tool.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Mounting:\u003c\/strong\u003e Secure the controller onto a standard EN 50022 35 x 7.5 mm or 35 x 15 mm DIN rail prior to wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Isolation:\u003c\/strong\u003e Ensure separate SELV\/PELV-listed 24V DC external power sources are provided for the MOD power and SA power terminal blocks to prevent system noise propagation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Verification:\u003c\/strong\u003e Verify correct polarity and wire gauge for MOD power (max 5 A bus limit) and SA power (max 10 A bus limit) connectors before applying power.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBus Termination:\u003c\/strong\u003e Always install the 5069-ECR end cap on the final Compact 5000 module or controller right side to protect internal power and communication buses from short circuits or ESD damage.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eConfiguration and Commissioning\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSoftware Environment:\u003c\/strong\u003e Configure the safety controller using Studio 5000 Logix Designer version 31.00.00 or later.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP Address Assignment:\u003c\/strong\u003e Assign network communication parameters using the BOOTP\/DHCP utility, RSLinx Classic, or Studio 5000 over USB or Ethernet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Network Number (SNN):\u003c\/strong\u003e Generate and assign a unique Safety Network Number to the controller and associated CIP Safety devices in the project tree to validate safety cross-checking.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Locking:\u003c\/strong\u003e Once safety routines and program logic are verified, generate the Safety Signature and apply safety-lock protection via Studio 5000 to prevent unauthorized logic modifications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-Volatile Backup:\u003c\/strong\u003e Transfer the fully validated project logic and network configuration onto the installed 1784-SD2 card for automatic restore on power cycles.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":53724037579115,"sku":"5069-L330ERMS2","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/5069-L330ERMS2_001_1200x1200_1244bb18-88b4-4ae4-8592-9825842ed3e0.jpg?v=1786712010"},{"product_id":"allen-bradley-5069-l330erms3-compact-guardlogix-5380-sil3-safety-controller","title":"Allen-Bradley 5069-L330ERMS3 Compact GuardLogix 5380 SIL3 Safety Controller","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 5069-L330ERMS3\u003c\/strong\u003e is a Compact GuardLogix 5380 safety controller designed to deliver high-performance standard and safety control for demanding industrial applications. Engineered on a quad-core processor architecture, this safety controller integrates dedicated system and safety memory to execute complex logic, integrated motion over EtherNet\/IP, and safety functions within a single unified platform. It provides functional safety capability up to SIL 3 (IEC 62061) and Performance Level e (PL e, ISO 13849-1), making it ideal for machinery and process applications requiring stringent safety standards.\u003c\/p\u003e\n\u003cp\u003eThe controller is equipped with 3.0 MB of standard user memory and 1.5 MB of dedicated safety memory. It supports system expansion with up to 31 local Compact 5000 I\/O modules, up to 60 EtherNet\/IP nodes, and up to 16 motion axes. Built-in dual gigabit EtherNet\/IP ports offer versatile networking configurations, supporting Dual-IP mode for separate network segmentation or Linear\/DLR (Device Level Ring) topologies for fault-tolerant network resiliency. System configuration and safety programming are performed seamlessly using the Studio 5000 Logix Designer application (version 32 or later).\u003c\/p\u003e\n\u003cp\u003ePower distribution across the \u003cstrong\u003e5069-L330ERMS3\u003c\/strong\u003e system relies on two distinct external connections: Module Power (MOD), which drives the controller processor and local I\/O module electronics, and Sensor\/Actuator Power (SA), which delivers power to field-side devices. For functional safety compliance, both MOD and SA power circuits require SELV\/PELV certified power supplies. Physical installation is simplified via DIN-rail mounting, featuring integrated chassis grounding directly through a zinc-plated chromate DIN rail.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Integrity Functional Safety\u003c\/strong\u003e: Certified for SIL 3 \/ SILCL 3 (EN 62061 \/ IEC 61508) and Cat. 4 \/ PL e (EN ISO 13849-1) safety execution.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Performance Memory Architecture\u003c\/strong\u003e: Features 3.0 MB standard memory and 1.5 MB dedicated safety memory driven by a quad-core processor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Motion Capability\u003c\/strong\u003e: Supports up to 16 axes of motion control over EtherNet\/IP alongside standard and safety logic execution.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Dual Gigabit Ethernet\u003c\/strong\u003e: Dual 1 Gb EtherNet\/IP ports support Dual-IP addressing for separate network segments or Linear\/DLR topologies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocal I\/O Capacity\u003c\/strong\u003e: Direct local expansion supporting up to 31 Compact 5000 I\/O modules on the right side of the controller.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Isolated Power Structure\u003c\/strong\u003e: Separate MOD (system-side) and SA (field-side) power connections isolate control electronics from field device transients.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOnboard Diagnostic Display\u003c\/strong\u003e: Features a 4-character visual status display and multiple LED indicators for immediate system, power, and network status diagnostics.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard USB Maintenance Port\u003c\/strong\u003e: Includes an front-panel USB port for local temporary programming, firmware flashing, and initial IP address configuration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomotive Assembly \u0026amp; Robotic Cells\u003c\/strong\u003e: Executing SIL 3 functional safety, interlocking, emergency stop monitoring, and multi-axis synchronized drive control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial Handling \u0026amp; High-Speed Packaging\u003c\/strong\u003e: Managing complex sorting, conveyancing, integrated motion, and safety light curtains over EtherNet\/IP networks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcess Machinery Safety Systems\u003c\/strong\u003e: Coordinating safe torque off (STO), safety zone control, and standard process logic in automated production lines.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiscrete Manufacturing Equipment\u003c\/strong\u003e: Providing dual-network segmentation and integrated motion control for standalone or networked OEM machine tools.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eRockwell Automation \/ Allen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand \/ Platform\u003c\/td\u003e\n\u003ctd\u003eCompact GuardLogix 5380\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e5069-L330ERMS3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Identifier\u003c\/td\u003e\n\u003ctd\u003e889508554129\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eSingapore\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor\u003c\/td\u003e\n\u003ctd\u003eQuad Core\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Memory\u003c\/td\u003e\n\u003ctd\u003e3.0 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Memory\u003c\/td\u003e\n\u003ctd\u003e1.5 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Local I\/O Expansion\u003c\/td\u003e\n\u003ctd\u003e31 Compact 5000 I\/O modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax EtherNet\/IP Nodes\u003c\/td\u003e\n\u003ctd\u003e60 nodes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotion Axis Support\u003c\/td\u003e\n\u003ctd\u003e16 axes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e4-character status display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eElectrical \u0026amp; Power Distribution\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMOD Power Voltage Range\u003c\/td\u003e\n\u003ctd\u003e18…32V DC SELV\/PELV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMOD Power Bus Max Current\u003c\/td\u003e\n\u003ctd\u003e5 A max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMOD Power Inrush Current\u003c\/td\u003e\n\u003ctd\u003e2.375 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSA Power Voltage Range\u003c\/td\u003e\n\u003ctd\u003e0…32V DC SELV\/PELV (for safety applications)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSA Power Bus Max Current\u003c\/td\u003e\n\u003ctd\u003e10 A max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation at Full Load\u003c\/td\u003e\n\u003ctd\u003e18 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Power Consumption\u003c\/td\u003e\n\u003ctd\u003eConsumes power from MOD power bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eCommunication \u0026amp; Connectivity\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Ports\u003c\/td\u003e\n\u003ctd\u003e2 x 1 Gb EtherNet ports (RJ45)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Network Topologies\u003c\/td\u003e\n\u003ctd\u003eDual-IP, Linear, Device Level Ring (DLR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB Port\u003c\/td\u003e\n\u003ctd\u003e1 x USB port (temporary programming only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB Cable Length\u003c\/td\u003e\n\u003ctd\u003e3.0 m max (no hubs allowed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eMechanical \u0026amp; Environmental\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eEN50022 - 35 x 7.5 mm zinc-plated chromate steel DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 degC (32 to 140 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Type\u003c\/td\u003e\n\u003ctd\u003eOpen-type rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrounding Connection\u003c\/td\u003e\n\u003ctd\u003eDirect chassis grounding via DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e123.0 mm x 136.81 mm x 132.43 mm (4.84 in. x 5.39 in. x 5.21 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eIsolation\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSA and MOD to Module Bus\u003c\/td\u003e\n\u003ctd\u003e300V (continuous), basic insulation type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet to Module Bus\u003c\/td\u003e\n\u003ctd\u003e300V (continuous), basic insulation type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet to MOD Power\u003c\/td\u003e\n\u003ctd\u003e300V (continuous), double insulation type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet to SA Power\u003c\/td\u003e\n\u003ctd\u003e300V (continuous), double insulation type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB to Module Bus\u003c\/td\u003e\n\u003ctd\u003e300V (continuous), basic insulation type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB to MOD \/ SA Power\u003c\/td\u003e\n\u003ctd\u003e300V (continuous), double insulation type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Type Test\u003c\/td\u003e\n\u003ctd\u003e1500V AC for 60 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnection Point\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription \/ Function\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMOD Power Terminal Block\u003c\/td\u003e\n\u003ctd\u003eRemovable Terminal Block (5069-RTB4) for connecting +24V DC system power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSA Power Terminal Block\u003c\/td\u003e\n\u003ctd\u003eRemovable Terminal Block (5069-RTB6) for connecting +24V DC field sensor\/actuator power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDual RJ45 Ports\u003c\/td\u003e\n\u003ctd\u003eLocated on the bottom of the controller for 10\/100\/1000 Mbps EtherNet\/IP network connections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB Port\u003c\/td\u003e\n\u003ctd\u003eFront-access USB port for local configuration and Studio 5000 access\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSD Card Slot\u003c\/td\u003e\n\u003ctd\u003eMemory card slot supporting industrial SD card for non-volatile project backup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Verification\u003c\/strong\u003e: Ensure the mounting enclosure provides an open-type rating suitable for Pollution Degree 2 environments and ambient operation between 0 degC and 60 degC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Mounting\u003c\/strong\u003e: Mount a zinc-plated chromate steel DIN rail horizontally. Verify that the DIN rail is securely grounded to the enclosure frame backplate.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eController Placement\u003c\/strong\u003e: Position the 5069-L330ERMS3 as the leftmost module on the DIN rail. Press firmly onto the DIN rail until the latches click into place.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocal I\/O \u0026amp; End Cap\u003c\/strong\u003e: Install any local Compact 5000 I\/O modules to the right of the controller. Ensure the rightmost module is fitted with the 5069 terminal end cap to protect the exposed module bus connectors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Wiring\u003c\/strong\u003e: Wire the 5069-RTB4 (MOD) and 5069-RTB6 (SA) removable terminal blocks using SELV\/PELV power supplies. Tighten screw terminals to 0.4 Nm torque. Ensure power supplies are powered off before inserting terminal blocks into the controller.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Connectivity\u003c\/strong\u003e: Connect standard shielded RJ45 Ethernet cables to the gigabit Ethernet ports.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eConfiguration and Commissioning Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eInitial IP Assignment\u003c\/strong\u003e: Connect a PC to the controller via the front panel USB port or use the EtherNet\/IP BOOTP-DHCP Server utility (version 3.02.00 or later) \/ RSLinx Classic (version 4.10.00 or later) to allocate an initial IP address.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMode Selection\u003c\/strong\u003e: Choose between Dual-IP mode (independent IP addresses per port for enterprise\/control layer isolation) or Linear\/DLR mode within RSLinx Classic or Studio 5000 Logix Designer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Logic Programming\u003c\/strong\u003e: Open Studio 5000 Logix Designer (version 32 or later). Create a project selecting model 5069-L330ERMS3. Configure safety task signatures, safety network numbers (SNN), and safe motion profiles according to functional safety requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Verification \u0026amp; Backup\u003c\/strong\u003e: Perform mandatory safety system validation checks. Once commissioned, transfer the verified application binary and safety signature to the industrial SD card for non-volatile storage.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eReplacement Recommendations\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Isolation\u003c\/strong\u003e: Turn off external MOD power and SA power supplies before attempting replacement. \u003cstrong\u003eCaution\u003c\/strong\u003e: The controller does not support Removal and Insertion Under Power (RIUP). Removing the controller under power will cause arc flash hazards and interrupt the local module bus.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Disconnection\u003c\/strong\u003e: Release the handles on the 5069-RTB4 and 5069-RTB6 removable terminal blocks and pull them out without disturbing field wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHardware Swapping\u003c\/strong\u003e: Unclip Ethernet cables, pull the latch mechanisms downward, and remove the original unit from the DIN rail. Install the replacement 5069-L330ERMS3 controller.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRestoration\u003c\/strong\u003e: Reinsert terminal blocks and network cables. Apply MOD and SA power. Restore project logic and safety parameters via Studio 5000 Logix Designer or automatically load the project from the pre-existing SD memory card.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunctional Safety\u003c\/strong\u003e: Certified Cat. 4 \/ PL e (EN ISO 13849-1) and SIL 3 \/ SILCL 3 (EN 62061 \/ IEC 61508)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEuropean Machinery Directive\u003c\/strong\u003e: Compliant with 2006\/42\/EC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Locations\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003eNorth America: Class I, Division 2, Groups A, B, C, D\u003c\/li\u003e\n\u003cli\u003eATEX: II 3 G Ex nA IIC T4 Gc (DEMKO19ATEX2261X)\u003c\/li\u003e\n\u003cli\u003eIECEx: Ex nA IIC T4 Gc (IECEx UL 19.0081X)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE Compliance\u003c\/strong\u003e: Compliant with European Directives\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":53724085780843,"sku":"5069-L330ERMS3","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/5069-L330ERMS3_002_1200x1200_b7706f82-4b50-49ed-9ad3-bc2df020470d.jpg?v=1786713448"}],"url":"https:\/\/www.plcprotech.com\/it\/collections\/allen-bradley-compact-5000.oembed?page=2","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}