{"title":"Honeywell Experion LX (Series 8)","description":"\u003cp\u003eThe Honeywell Experion LX (Series 8) is a purpose-built DCS solution designed for small-to-mid-sized process applications. The architecture utilizes the Series 8 I\/O modules (8C- prefix) and C200E\/C300-style controllers, providing a compact yet powerful control footprint. Key technical characteristics include vertical module orientation for efficient cooling, integrated HART support, and a scalable Ethernet backbone. Functionally, Experion LX offers the same high-end features as the PKS system—such as advanced alarm management and asset health monitoring—but is tailored for industries like food and beverage or specialty chemicals. It provides a cost-effective bridge for users moving from \u003ca href=\"https:\/\/www.plcprotech.com\/collections\/honeywell-controledge-hc900-plc\"\u003eHC900 PLC\u003c\/a\u003e systems to a full distributed control environment.\u003c\/p\u003e","products":[{"product_id":"honeywell-8c-taox51-51306983-175-plantcruise-series-8-analog-output-iota","title":"Honeywell 8C-TAOX51 51306983-175 PlantCruise Series 8 Analog Output IOTA","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell 8C-TAOX51\u003c\/strong\u003e (part number \u003cstrong\u003e51306983-175\u003c\/strong\u003e) is a conformal-coated, non-redundant 6-inch Input Output Termination Assembly (\u003cstrong\u003eIOTA\u003c\/strong\u003e) designed for \u003cstrong\u003ePlantCruise Series 8\u003c\/strong\u003e process control systems. It combines field wiring termination and the Analog Output Input Output Module (\u003cstrong\u003eIOM\u003c\/strong\u003e) into a single compact area, eliminating the need for a separate electronics chassis. Operating directly from a 24 VDC carrier power bus, the unit delivers non-incendive field power distribution across 16 channels without requiring external marshalling or inline fusing. The assembly features two-level detachable screw terminals, integrated signal conditioning, and on-board connection to the I\/O Link for standard 4-20 mA and HART-capable analog output operations.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCombines field terminations and I\/O module mounting in a single unit, eliminating external chassis requirements.\u003c\/li\u003e\n\u003cli\u003eEquipped with two-level detachable terminal blocks for simple field wiring installation and maintenance.\u003c\/li\u003e\n\u003cli\u003eSupplies non-incendive field power directly through an integrated 24 VDC bus connection on the carrier.\u003c\/li\u003e\n\u003cli\u003eConformal coating protection (8C designator) against humidity, dust, chemicals, and temperature extremes.\u003c\/li\u003e\n\u003cli\u003eVertical mounting orientation and tilted physical layout engineered for cabinet space efficiency and heat management.\u003c\/li\u003e\n\u003cli\u003eShort-circuit protected output circuits that eliminate inline fusing needs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eField wiring termination and power distribution for 16-channel 4-20 mA analog output devices.\u003c\/li\u003e\n\u003cli\u003eInterfacing actuators, positioners, and recording instruments in Honeywell PlantCruise by Experion architectures.\u003c\/li\u003e\n\u003cli\u003eClass 1, Division 2 hazardous area deployments requiring non-incendive field power conditioning.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSize\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eRedundancy Support\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e8C-TAOX51\u003c\/td\u003e\n\u003ctd\u003eAO IOTA, Coated\u003c\/td\u003e\n\u003ctd\u003e6 in (152 mm)\u003c\/td\u003e\n\u003ctd\u003eNon-Redundant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e8C-TAOX61\u003c\/td\u003e\n\u003ctd\u003eAO IOTA, Coated\u003c\/td\u003e\n\u003ctd\u003e12 in (304 mm)\u003c\/td\u003e\n\u003ctd\u003eRedundant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e8U-TAOX51\u003c\/td\u003e\n\u003ctd\u003eAO IOTA, Uncoated\u003c\/td\u003e\n\u003ctd\u003e6 in (152 mm)\u003c\/td\u003e\n\u003ctd\u003eNon-Redundant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e8U-TAOX61\u003c\/td\u003e\n\u003ctd\u003eAO IOTA, Uncoated\u003c\/td\u003e\n\u003ctd\u003e12 in (304 mm)\u003c\/td\u003e\n\u003ctd\u003eRedundant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e8C-TAOX51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e51306983-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eInput Output Termination Assembly (IOTA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003ePlantCruise Series 8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Coating\u003c\/td\u003e\n\u003ctd\u003eConformal Coated (8C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIOTA Size\u003c\/td\u003e\n\u003ctd\u003eNominal 6 inches (152 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy\u003c\/td\u003e\n\u003ctd\u003eNon-Redundant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Channel Count\u003c\/td\u003e\n\u003ctd\u003e16 Circuits \/ Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Input\u003c\/td\u003e\n\u003ctd\u003e24 VDC bus (screw-mounted to carrier bus)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Power Distribution\u003c\/td\u003e\n\u003ctd\u003eNon-incendive output (no external field power required)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Connection Type\u003c\/td\u003e\n\u003ctd\u003eTwo-level detachable terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Wire Size\u003c\/td\u003e\n\u003ctd\u003eUp to 12 AWG \/ 2.5 mm2 stranded wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Output Modules\u003c\/td\u003e\n\u003ctd\u003e8C-PAOH51, 8U-PAOH51, 8C-PAON01, 8U-PAON01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Output Type\u003c\/td\u003e\n\u003ctd\u003e4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Ripple\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 100 mV peak-to-peak at power line frequency across 250 ohm load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.05% of Full Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibrated Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.35% of Full Scale (25 degC) including linearity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSettable Output Range\u003c\/td\u003e\n\u003ctd\u003e0 mA, 2.9 mA to 21.1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Open Circuit Voltage\u003c\/td\u003e\n\u003ctd\u003e22 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector \/ Interface\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetachable Field Terminals\u003c\/td\u003e\n\u003ctd\u003eTwo-level wiring terminals for 16-channel analog output field connections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarrier Bus Connection\u003c\/td\u003e\n\u003ctd\u003eMechanical screw connections for receiving 24 VDC system power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIOM Mounting Interface\u003c\/td\u003e\n\u003ctd\u003eDirect plug-in slot for Series 8 Analog Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Connection\u003c\/td\u003e\n\u003ctd\u003eIntegrated connection to I\/O Link network\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount vertically inside system cabinets to align with field wiring entry from cabinet top or bottom.\u003c\/li\u003e\n\u003cli\u003eEnsure natural ventilation by using the tilted hardware design for thermal dissipation.\u003c\/li\u003e\n\u003cli\u003eScrew the termination assembly directly onto the 24 VDC bussed power carrier.\u003c\/li\u003e\n\u003cli\u003eLand field wiring on the two-level detachable terminals using stranded conductors up to 12 AWG (2.5 mm2).\u003c\/li\u003e\n\u003cli\u003eVerify non-incendive wiring practices when installing in Class 1, Division 2 hazardous environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eClass 1, Division 2 Hazardous Location Non-Incendive Rating\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667742060907,"sku":"8C-TAOX51 51306983-175","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-8c-taox51-51306983-175-analog-output-module-ciqzsbg3qxx_30f39685-af58-4ab5-b322-2ab9e3eea638.jpg?v=1765501420"},{"product_id":"honeywell-8c-paoha1-51454469-275-analog-output-module","title":"Honeywell 8C-PAOHA1 51454469-275 Analog Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell 8C-PAOHA1 (Model 51454469-275) is a high-density analog output module engineered for Honeywell Experion Process Knowledge System (PKS) architectures. As part of the Series C platform, this hardware interfaces the control system with final control elements such as control valves, actuators, and variable speed drives by converting controller digital values into precise analog current signals. Its space-saving form factor optimizes cabinet footprint while delivering reliable process control across demanding industrial installations.\u003c\/p\u003e\n\u003cp\u003eThe module is designed to mount on standard Series C I\/O carriers and connects directly to the system architecture via redundant I\/O communication links. It handles multi-channel analog output distribution with built-in channel-level diagnostics, supporting continuous supervision of loop integrity and device health. This minimizes manual troubleshooting and helps maintain uninterrupted process operation.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSeries C I\/O form factor designed for high-density cabinet layouts\u003c\/li\u003e\n  \u003cli\u003ePrecision analog output channels for actuators, positioners, and modulating valves\u003c\/li\u003e\n  \u003cli\u003eIntegrated diagnostic monitoring for open-circuit and short-circuit detection\u003c\/li\u003e\n  \u003cli\u003eDirect insertion mounting on Series C I\/O termination assemblies\u003c\/li\u003e\n  \u003cli\u003eSupports redundant module configurations for high-availability control strategies\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOil and gas extraction and refining facilities\u003c\/li\u003e\n  \u003cli\u003eChemical and petrochemical processing plants\u003c\/li\u003e\n  \u003cli\u003ePower generation and utility boiler controls\u003c\/li\u003e\n  \u003cli\u003eWater and wastewater treatment installations\u003c\/li\u003e\n  \u003cli\u003eLarge-scale continuous manufacturing process control\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eHoneywell\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Series\u003c\/td\u003e\n      \u003ctd\u003eExperion PKS \/ Series C\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eExact Model \/ Part Number\u003c\/td\u003e\n      \u003ctd\u003e8C-PAOHA1 (51454469-275)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModule Type\u003c\/td\u003e\n      \u003ctd\u003eAnalog Output Module\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMounting Type\u003c\/td\u003e\n      \u003ctd\u003eSeries C I\/O Carrier\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd\u003e0 to 60 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStorage Temperature\u003c\/td\u003e\n      \u003ctd\u003e-40 to 85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRelative Humidity\u003c\/td\u003e\n      \u003ctd\u003e5 to 95 percent, non-condensing\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCountry of Origin\u003c\/td\u003e\n      \u003ctd\u003eUSA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNet Weight\u003c\/td\u003e\n      \u003ctd\u003e0.3 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDimensions\u003c\/td\u003e\n      \u003ctd\u003e6.0 cm x 15.6 cm x 14.3 cm\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eVerify part numbers and inspect the module and Series C carrier for any shipping damage before installation.\u003c\/li\u003e\n  \u003cli\u003eEnsure all power to the target I\/O slot and associated field wiring terminal blocks is de-energized.\u003c\/li\u003e\n  \u003cli\u003eSlide the 8C-PAOHA1 module straight into the designated Series C I\/O carrier slot, taking care not to bend backplane pins.\u003c\/li\u003e\n  \u003cli\u003eSecure the module using the integrated locking mechanism according to hardware specifications.\u003c\/li\u003e\n  \u003cli\u003eVerify field wiring terminations on the I\/O termination assembly before restoring system power.\u003c\/li\u003e\n  \u003cli\u003ePower up the node and use Experion Engineering Station tools to verify module recognition and channel configuration.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667747565931,"sku":"8C-PAOHA1 51454469-275","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-8c-paoha1-51454469-275-analog-output-module-2vsfnn1ntrq_44596505-7697-4ad4-a887-1b2604c72629.jpg?v=1765501508"},{"product_id":"honeywell-8c-pain01-51454356-175-series-8-coated-high-level-analog-input-module","title":"Honeywell 8C-PAIN01 51454356-175 Series 8 Coated High-Level Analog Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell 8C-PAIN01\u003c\/strong\u003e (Part Number \u003cstrong\u003e51454356-175\u003c\/strong\u003e) is a conformally coated, 16-channel High-Level Analog Input Module (IOM) designed for high-density analog signal processing within the Honeywell Experion Process Knowledge System (PKS) and PlantCruise by Experion Series 8 I\/O architecture. Operating under the control of the C300 Controller, the module interfaces directly with 4-20 mA DC current signals from 2-wire field transmitters or self-powered process instruments.\u003c\/p\u003e\n\u003cp\u003eArchitecturally, the \u003cstrong\u003eHoneywell 8C-PAIN01\u003c\/strong\u003e mounts directly onto a Series 8 Input Output Termination Assembly (IOTA) via physical blind-mating connectors, completely eliminating the need for a separate electronic chassis or external marshalling racks. Its physical form factor features the signature Series 8 tilted housing layout, which optimizes thermal dissipation performance and allows high cabinet packing density without compromise to system availability.\u003c\/p\u003e\n\u003cp\u003eEngineered with conformal coating (designated by the 8C prefix), the \u003cstrong\u003eHoneywell 8C-PAIN01\u003c\/strong\u003e internal circuitry is protected against atmospheric moisture, conductive dust, airborne chemical contaminants, and temperature extremes. The module includes integrated, individually protected current-limiting power distribution to feed field transmitters directly from the IOTA. This built-in signal conditioning provides Class 1, Division 2 non-incendive field power without requiring external user-supplied field power supplies or inline field fuses.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e16 Single-Ended Input Channels:\u003c\/strong\u003e Accepts standard 4-20 mA analog signals across a 200 ohm sense resistor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e16-Bit A\/D Resolution:\u003c\/strong\u003e High-resolution analog-to-digital conversion provides precise input sampling for process control variables.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFast Loop Execution:\u003c\/strong\u003e Features a 50 ms input scan rate across all channels for rapid process variable updates to the C300 controller.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConformally Coated Assembly:\u003c\/strong\u003e Provides physical circuit board protection against harsh environmental contaminants, humidity, and chemical exposure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-Incendive Transmitter Power:\u003c\/strong\u003e Delivers integrated, current-limited transmitter field power supporting Class 1, Div 2 hazardous locations without external marshalling or fuses.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundant \u0026amp; Non-Redundant Configurations:\u003c\/strong\u003e Plugs onto the 6-inch non-redundant IOTA (8C-TAIX51) or the 12-inch redundant IOTA (8C-TAIX61) where dual IOMs reside on a single assembly without external switchover cabling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Heat Management:\u003c\/strong\u003e Tilted vertical module design promotes cabinet air circulation and heat dissipation in high-density installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcess Variable Monitoring:\u003c\/strong\u003e Continuous current loop measurement from pressure, flow, level, and temperature transmitters in continuous or batch process environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDCS Control Loop Inputs:\u003c\/strong\u003e Direct process variable (PV) feedback to the C300 Controller for PID control strategies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area Field Interfacing:\u003c\/strong\u003e Powering and acquiring 4-20 mA current loops in Class 1, Division 2 process plant environments using non-incendive circuit topology.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e8C-PAIN01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e51454356-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries \/ Platform\u003c\/td\u003e\n\u003ctd\u003eSeries 8 I\/O \/ PlantCruise by Experion \/ Experion PKS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eHigh-Level Analog Input Module (Coated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e16 Channels (Single-Ended)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Type\u003c\/td\u003e\n\u003ctd\u003e4-20 mA DC (2-wire or self-powered transmitters)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA\/D Converter Resolution\u003c\/td\u003e\n\u003ctd\u003e16 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Resistance \/ Range\u003c\/td\u003e\n\u003ctd\u003e4-20 mA through 200 ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Scan Rate\u003c\/td\u003e\n\u003ctd\u003e50 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardware Accuracy (@ CMV = 0 V)\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e+\/-0.075% of full-scale (23.5 degC +\/- 2 degC)\u003c\/p\u003e\n\u003cp\u003e+\/-0.15% of full-scale (0 to 60 degC)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Non-Damaging Input Voltage\u003c\/td\u003e\n\u003ctd\u003e+\/-30 VDC (any input referenced to common)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNormal Mode Rejection Ratio (NMRR)\u003c\/td\u003e\n\u003ctd\u003e19 dB at 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNormal Mode Filter Response\u003c\/td\u003e\n\u003ctd\u003eSingle-pole RC, -3 dB @ 6.5 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel-to-Channel Crosstalk\u003c\/td\u003e\n\u003ctd\u003e-60 dB (DC to 60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Power Conditioning\u003c\/td\u003e\n\u003ctd\u003eIndividually protected current-limiting circuits (Class 1, Div 2 non-incendive)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Non-Redundant IOTA\u003c\/td\u003e\n\u003ctd\u003e8C-TAIX51 (Coated, 6-inch \/ 152 mm width)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Redundant IOTA\u003c\/td\u003e\n\u003ctd\u003e8C-TAIX61 (Coated, 12-inch \/ 304 mm width)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Verification:\u003c\/strong\u003e Confirm that the mounting environment matches the module specifications. Though the \u003cstrong\u003eHoneywell 8C-PAIN01\u003c\/strong\u003e features conformal coating, cabinet temperature should remain within 0 to 60 degC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIOTA Installation:\u003c\/strong\u003e Mount the compatible IOTA assembly (8C-TAIX51 for single, 8C-TAIX61 for redundant configurations) to the cabinet mounting channel. Securely fasten the bushed 24 VDC power connections to the backplane carrier.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Wiring Termination:\u003c\/strong\u003e Land field instrument wiring at the two-level detachable screw terminals on the IOTA. Ensure signal polarity matches 2-wire powered or self-powered loop configurations (wiring accepts up to 12 AWG \/ 2.5 mm2 stranded wire).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Insertion:\u003c\/strong\u003e Align the rear connector pins of the \u003cstrong\u003e8C-PAIN01\u003c\/strong\u003e module with the dedicated IOM slot on the IOTA. Press firmly until the mechanical latches seat completely.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundant Assembly Setup:\u003c\/strong\u003e If configuring redundant analog inputs on an 8C-TAIX61 IOTA, insert two identical \u003cstrong\u003e8C-PAIN01\u003c\/strong\u003e modules into the primary and secondary slots. Redundancy control is handled directly by the IOTA hardware backplane without external interconnect cables.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eConfiguration Recommendations\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Assignment:\u003c\/strong\u003e Assign the \u003cstrong\u003e8C-PAIN01\u003c\/strong\u003e module to its designated I\/O Link channel under the host C300 Controller configuration tree in the engineering environment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel Parameterization:\u003c\/strong\u003e Define the input signal range, PV scaling limits, filter constant, and failure state handling for each of the 16 analog channels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Budgeting Check:\u003c\/strong\u003e Verify total current consumption from 2-wire field loops to ensure the IOTA 24 VDC supply bus remains well within operational margins during normal field instrument draw.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommissioning \u0026amp; Diagnostic Verification:\u003c\/strong\u003e Prior to placing loops into auto control, inspect the Series 8 status indicator on the module front panel to confirm green operational health and verify individual process values at the engineering station.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667755397483,"sku":"8C-PAIN01 51454356-175","price":1800.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/8C-PAIN01-51454356-175_001_1200x1200_6ea21ba4-56a0-45b7-a951-3307a52b0c70.jpg?v=1786802593"},{"product_id":"honeywell-8c-sheda1-51307186-175-series-8-digital-input-board","title":"Honeywell 8C-SHEDA1 51307186-175 Series 8 Digital Input Board","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell \u003cstrong\u003e8C-SHEDA1\u003c\/strong\u003e (model 51307186-175) is a specialized digital input board designed for deployment within Honeywell Series 8 distributed control systems. This header board interfaces discrete field signals with automation infrastructure, providing reliable signal routing and system communication.\u003c\/p\u003e\n\u003cp\u003eEngineered for continuous industrial process control environments, the module supports standard automation architectures and facilitates stable data exchange between field instrumentation and the broader control network. Its specialized hardware layout ensures dependable performance in demanding monitoring and control tasks.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDesigned specifically for integration within Honeywell Series 8 control infrastructure\u003c\/li\u003e\n  \u003cli\u003eFacilitates reliable processing and routing of discrete digital input signals\u003c\/li\u003e\n  \u003cli\u003eConstructed for continuous operation in standard industrial temperature ranges\u003c\/li\u003e\n  \u003cli\u003eEmploys secure connection interfaces to maintain uninterrupted signal integrity\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDistributed Control Systems (DCS) for process manufacturing\u003c\/li\u003e\n  \u003cli\u003eOil and gas refining and petrochemical processing plants\u003c\/li\u003e\n  \u003cli\u003ePower generation and utility automation systems\u003c\/li\u003e\n  \u003cli\u003eChemical production and heavy industrial monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eHoneywell\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Series\u003c\/td\u003e\n      \u003ctd\u003eSeries 8\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModel \/ Part Number\u003c\/td\u003e\n      \u003ctd\u003e8C-SHEDA1\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCatalog Number\u003c\/td\u003e\n      \u003ctd\u003e51307186-175\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModule Type\u003c\/td\u003e\n      \u003ctd\u003eDigital Input Board \/ Header Board\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSystem Platform\u003c\/td\u003e\n      \u003ctd\u003eHoneywell Experion \/ Series 8 DCS\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCountry of Origin\u003c\/td\u003e\n      \u003ctd\u003eUnited States\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eVerify that the part number 8C-SHEDA1 51307186-175 matches system engineering documentation before proceeding.\u003c\/li\u003e\n  \u003cli\u003eDe-energize the associated Series 8 chassis and disconnect all power sources prior to physical handling.\u003c\/li\u003e\n  \u003cli\u003eInspect the board connectors and pins for any signs of transit damage or contamination.\u003c\/li\u003e\n  \u003cli\u003eMount the digital input board securely into the designated Series 8 slot in accordance with hardware layout rules.\u003c\/li\u003e\n  \u003cli\u003eConnect field wiring and interface cables securely to the appropriate terminal points.\u003c\/li\u003e\n  \u003cli\u003eRestore system power and verify module status indicators through the engineering workstation.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667761328491,"sku":"8C-SHEDA1 51307186-175","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-8c-sheda1-51307186-175-digital-input-board-ab2ocz10421_919ad80c-b915-4b1a-969a-2b50be7bd7b2.jpg?v=1765501713"},{"product_id":"honeywell-8c-paih54-51307070-275-experion-lx-series-8-differential-analog-input-module-with-hart","title":"Honeywell 8C-PAIH54 51307070-275 Experion LX Series 8 Differential Analog Input Module with HART","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell \u003cstrong\u003e8C-PAIH54\u003c\/strong\u003e (Part Number \u003cstrong\u003e51307070-275\u003c\/strong\u003e) is a conformal coated Differential Analog Input Module with HART designed for process measurement and monitoring in Experion LX Series 8 control systems. Operating within the Series 8 I\/O architecture, the module interfaces differential 4-20 mA DC transmitter signals and HART digital communications directly to the C300 controller across the system I\/O Link.\u003c\/p\u003e\n\u003cp\u003eThe module provides 16 differential input channels and features a factory-applied conformal coating (8C- prefix) to protect electronic circuitry against moisture, dust, chemical contaminants, and environmental harshness. It mounts directly onto an Input Output Termination Assembly (IOTA), eliminating the need for a separate electronic card chassis. Field wiring is landed on removable two-level terminal blocks on the IOTA, which also handles internal field power distribution.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003e8C-PAIH54\u003c\/strong\u003e supports both non-redundant and hardware-redundant control configurations when combined with the appropriate IOTA board (8C-TAIDA1 or 8C-TAIDB1). Redundancy is implemented directly on the IOTA base without external switchover logic or special interconnect cables by attaching a second IOM. Secondary and tertiary HART variables along with device diagnostic status are transferred continuously to support process execution and asset maintenance.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e16 differential analog input channels handling standard 4-20 mA DC currents and HART digital protocol communications.\u003c\/li\u003e\n\u003cli\u003eConformal coated circuit board assembly (8C- series designation) for severe environment protection.\u003c\/li\u003e\n\u003cli\u003eDirect plug-in mounting onto Series 8 Input Output Termination Assemblies (IOTA), bypassing card cages.\u003c\/li\u003e\n\u003cli\u003eSupport for non-redundant (8C-TAIDA1) and redundant (8C-TAIDB1) termination assemblies.\u003c\/li\u003e\n\u003cli\u003eShort-circuit protected input channel architecture to shield electronics against field wiring faults.\u003c\/li\u003e\n\u003cli\u003eOn-board field power distribution routed through the IOTA board to reduce external marshalling terminals.\u003c\/li\u003e\n\u003cli\u003eVisual status indicator area on the front cover for quick operational checks.\u003c\/li\u003e\n\u003cli\u003eVertically mounted enclosure with an angled heat-dissipation layout for thermal management in dense cabinets.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDifferential pressure, flow, and level transmitter measurement loops in continuous process control.\u003c\/li\u003e\n\u003cli\u003eHART smart field device monitoring for real-time asset management and secondary variable collection.\u003c\/li\u003e\n\u003cli\u003eSignal acquisition in harsh atmospheric environments where conformal coating is mandated.\u003c\/li\u003e\n\u003cli\u003eRedundant analog input monitoring for critical control execution in Experion LX architectures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eComponent\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eOption \/ Variant\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e8C-PAIH54\u003c\/td\u003e\n\u003ctd\u003eDifferential Analog Input Module with HART, Coated\u003c\/td\u003e\n\u003ctd\u003eStandard IOM Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e8C-TAIDA1\u003c\/td\u003e\n\u003ctd\u003eDifferential AI IOTA, Non-Redundant, Coated (9 in \/ 228 mm)\u003c\/td\u003e\n\u003ctd\u003eOptional Base Termination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e8C-TAIDB1\u003c\/td\u003e\n\u003ctd\u003eDifferential AI IOTA, Redundant, Coated (12 in \/ 304 mm)\u003c\/td\u003e\n\u003ctd\u003eOptional Base Termination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003e8C-PAIH54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e51307070-275\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eExperion LX Series 8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Input with HART - Differential\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoating\u003c\/td\u003e\n\u003ctd\u003eConformal Coated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Capacity\u003c\/td\u003e\n\u003ctd\u003e16 Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal\u003c\/td\u003e\n\u003ctd\u003eDifferential 4-20 mA DC \/ HART\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eElectrical\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Draw (Non-Redundant with 8C-TAIDA1)\u003c\/td\u003e\n\u003ctd\u003e710 mA total @ 24 VDC (310 mA System \/ 400 mA Field)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Draw (Redundant with 8C-TAIDB1)\u003c\/td\u003e\n\u003ctd\u003e1020 mA total @ 24 VDC (620 mA System \/ 400 mA Field)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Field Supply Current\u003c\/td\u003e\n\u003ctd\u003e400 mA @ 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Protection\u003c\/td\u003e\n\u003ctd\u003eShort-circuit protected input circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eEnvironmental\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 degC to +60 degC (32 degF to +140 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC (-40 degF to +185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSinusoidal Vibration\u003c\/td\u003e\n\u003ctd\u003e10-57 Hz at 0.075 mm, 57-150 Hz at 1 G acceleration (3 axes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock Resistance\u003c\/td\u003e\n\u003ctd\u003e15 G peak, 11 ms duration (3 axes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Protection Class\u003c\/td\u003e\n\u003ctd\u003eIP54 minimum for wet\/outdoor areas; IP4X for protected areas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eCompliance and Certifications\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFM Approval\u003c\/td\u003e\n\u003ctd\u003eClass I, Division 2, Groups A, B, C, D; T4 \/ Class I, Zone 2, AEx\/Ex nA IIC T4 Gc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCSA Certification\u003c\/td\u003e\n\u003ctd\u003eClass I, Division 2, Groups A, B, C, D; T4 \/ Class I, Zone 2, Ex nA IIC T4 Gc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eATEX Marking\u003c\/td\u003e\n\u003ctd\u003eII 3G Ex nA IIC T4 Gc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIOTA Base Connector\u003c\/td\u003e\n\u003ctd\u003eMates directly to 8C-TAIDA1 or 8C-TAIDB1 IOTA boards for power and I\/O bus interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Terminations\u003c\/td\u003e\n\u003ctd\u003eTwo-level detachable screw terminal blocks on the IOTA for 4-20 mA device wiring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eConfirm that system power is disconnected before installing or servicing modules in hazardous locations.\u003c\/li\u003e\n\u003cli\u003eSecure the compatible IOTA assembly (8C-TAIDA1 or 8C-TAIDB1) vertically to the cabinet channel.\u003c\/li\u003e\n\u003cli\u003eEnsure the enclosure chassis is grounded using at least #8 AWG solid copper conductor.\u003c\/li\u003e\n\u003cli\u003eAlign the rear connectors of the \u003cstrong\u003e8C-PAIH54\u003c\/strong\u003e module with the standard receptacle on the IOTA and push firmly.\u003c\/li\u003e\n\u003cli\u003eTighten the two mounting screws on each side of the module cover to secure it to the IOTA board.\u003c\/li\u003e\n\u003cli\u003eObserve proper electro-static discharge (ESD) handling procedures, including grounding wrist straps.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eConfiguration and Commissioning Recommendations\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eDefine channel parameters, differential ranges, and HART variable assignments within Control Builder software.\u003c\/li\u003e\n\u003cli\u003eVerify transmitter loop power connections and polarity against the IOTA field terminal layout.\u003c\/li\u003e\n\u003cli\u003eSave controller configuration and parameter backups prior to module insertion or hardware swapping.\u003c\/li\u003e\n\u003cli\u003eVerify signal readings and HART communication status for each active input channel prior to process startup.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667997815147,"sku":"8C-PAIH54 51307070-275","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/8C-PAIH54-51307070-275_001_1200x1200_3bf25315-7063-4414-b31b-d5989fa18213.jpg?v=1786879143"},{"product_id":"honeywell-8c-pcnt03-51454363-375-series-8-c300-controller-processor-module","title":"Honeywell 8C-PCNT03 51454363-375 Series 8 C300 Controller Processor Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell 8C-PCNT03\u003c\/strong\u003e (Part Number \u003cstrong\u003e51454363-375\u003c\/strong\u003e) is a \u003cstrong\u003eC300 Controller Processor Module\u003c\/strong\u003e designed for real-time control strategy execution, batch processing, and process field management within the Honeywell Experion PKS Series 8 DCS architecture. Operating on the C300v3 hardware platform, this single-core controller unit executes deterministic control logic via Honeywell Control Execution Environment (CEE) software.\u003c\/p\u003e\n\u003cp\u003eBuilt for heavy-duty industrial process environments, the \u003cstrong\u003eHoneywell 8C-PCNT03 51454363-375\u003c\/strong\u003e features conformal coating on its circuit assembly to prevent corrosion from airborne contaminants, high humidity, and chemical exposure. The unit provides dedicated processing resources and high-capacity communication handling across standard Fault Tolerant Ethernet (FTE) control networks.\u003c\/p\u003e\n\u003cp\u003eThe controller module hosts 18 MB of CEE user memory and supports up to 4 Peer Gateway Module (PGM) network connections. It integrates directly into standard Series 8 carrier assemblies, interfacing with local I\/O modules and peer controllers across distributed process networks.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Execution Resource\u003c\/strong\u003e: Delivers 5500 processing execution units (Us) available for CPU consumption in loop execution and logic processing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDedicated CEE Memory\u003c\/strong\u003e: Equipped with 18 MB of CEE user memory dedicated to strategy configuration, continuous control blocks, and sequential operations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle-Core Architecture\u003c\/strong\u003e: Utilizes a single-core processor engine optimized for deterministic cycle execution.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Release Compatibility\u003c\/strong\u003e: Supported across Experion PKS software releases R110, R120, R500, R510, and R520.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMemory Backup Architecture\u003c\/strong\u003e: Interfaces with the 51454475-100 RAM charger module to ensure non-volatile program retention during main power failure events.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePGM Network Expansion\u003c\/strong\u003e: Supports up to 4 Peer Gateway Module (PGM) connections per C300 controller node.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData Access Throughput\u003c\/strong\u003e: Provides a conventional overall data access response rate of 2500 PPS.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSubscribed Parameter Capacity\u003c\/strong\u003e: Handles up to 4000 total subscribed parameters for display data access.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePeer-to-Peer Publishing\u003c\/strong\u003e: Supports peer-to-peer initiator pull\/get and target publish rates up to 1000 PPS.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConformal Coating Protection\u003c\/strong\u003e: Features factory conformal coating (coated 1, 3, 4) to withstand harsh ambient atmospheric environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDistributed Process Control\u003c\/strong\u003e: Primary processing engine for continuous process loops in chemical, refining, and energy production plants.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExperion PKS Automation\u003c\/strong\u003e: Control engine executing CEE control strategies, function blocks, and process interlocks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBatch Automation\u003c\/strong\u003e: Sequence execution and recipe execution in pharmaceutical and specialty chemical manufacturing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSubsystem Interface Control\u003c\/strong\u003e: Orchestration of field I\/O modules, serial interfaces, and peer controller data exchanges over FTE.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003e8C-PCNT03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e51454363-375\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Designation\u003c\/td\u003e\n\u003ctd\u003eSeries 8 C300 Controller Processor Module (C300v3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRAM Charger Module\u003c\/td\u003e\n\u003ctd\u003e51454475-100 (Required for RAM backup)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurface Protection\u003c\/td\u003e\n\u003ctd\u003eFactory Conformal Coating (Coated 1, 3, 4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003e8C-PCNT03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e51454363-375\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eC300 Controller Processor Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries Platform\u003c\/td\u003e\n\u003ctd\u003eExperion PKS Series 8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardware Generation\u003c\/td\u003e\n\u003ctd\u003eC300v3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessing Execution Units\u003c\/td\u003e\n\u003ctd\u003e5500 Us\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor Architecture\u003c\/td\u003e\n\u003ctd\u003eSingle Core\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCEE User Memory\u003c\/td\u003e\n\u003ctd\u003e18 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Backup Charger Module\u003c\/td\u003e\n\u003ctd\u003e51454475-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Experion Software Releases\u003c\/td\u003e\n\u003ctd\u003eExperion R110, R120, R500, R510, R520\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PGM Connections per C300\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall Data Access Response Rate\u003c\/td\u003e\n\u003ctd\u003e2500 PPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Data Access Capacity\u003c\/td\u003e\n\u003ctd\u003e4000 total subscribed parameters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeer Initiator Pull\/Get Rate\u003c\/td\u003e\n\u003ctd\u003e1000 PPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeer Target Publish Rate\u003c\/td\u003e\n\u003ctd\u003e1000 PPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeer-to-Peer Execution Capacity\u003c\/td\u003e\n\u003ctd\u003e100 @ 100 ms, 200 @ 200 ms, 500 @ 500 ms, 1000 @ 1 sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBoard Assembly Surface\u003c\/td\u003e\n\u003ctd\u003eConformal Coated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarrier Base Connection\u003c\/td\u003e\n\u003ctd\u003eDual-connector interface for Series 8 carrier backplane attachment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower and Network Bus\u003c\/td\u003e\n\u003ctd\u003eInternal backplane connection to FTE network bridges and system power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Module Port\u003c\/td\u003e\n\u003ctd\u003eDedicated header connection for the 51454475-100 RAM charger unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eInspect the 8C-PCNT03 module and carrier base for physical cleanliness prior to mounting.\u003c\/li\u003e\n\u003cli\u003eEnsure system power supplies to the target Series 8 mounting carrier are isolated or properly configured according to plant safety practices.\u003c\/li\u003e\n\u003cli\u003eAlign the rear edge connectors of the 8C-PCNT03 module with the dedicated controller slot on the Series 8 carrier assembly.\u003c\/li\u003e\n\u003cli\u003ePress the module firmly into place until the locking mechanism engages securely with the carrier.\u003c\/li\u003e\n\u003cli\u003eConnect the 51454475-100 RAM charger module to its designated backup terminal on the controller assembly.\u003c\/li\u003e\n\u003cli\u003eConfirm properly grounded carrier shielding and verify FTE Ethernet cabling connection to network switches.\u003c\/li\u003e\n\u003cli\u003eApply power and verify system LED status indicators proceed through initial boot diagnostic routines.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eConfiguration \/ Commissioning \/ Replacement Guidelines\u003c\/h3\u003e\n\u003ch4\u003eConfiguration Guidelines\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eUse Honeywell Control Builder within a compatible Experion PKS release (R110, R120, R500, R510, or R520) to define CEE control execution strategies.\u003c\/li\u003e\n\u003cli\u003eAssign proper FTE node addressing and controller memory allocations prior to downloading parameter files.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCommissioning Guidelines\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eVerify communication throughput to connected I\/O channels and peer controllers.\u003c\/li\u003e\n\u003cli\u003eMonitor memory consumption metrics to ensure strategy size fits within the 18 MB CEE user memory limit.\u003c\/li\u003e\n\u003cli\u003eConfirm RAM charger module charging voltage and backup functionality.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eReplacement Recommendations\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCross-Generational Redundancy Constraint\u003c\/strong\u003e: The 8C-PCNT03 (C300v3) module cannot be paired with an 8C-PCNT05 (C300v5) module in a redundant set, as cross-generational hardware will not synchronize redundancy states.\u003c\/li\u003e\n\u003cli\u003eWhen replacing an existing 8C-PCNT03 module, upload and back up current controller databases and parameter settings in Control Builder prior to removing the hardware unit.\u003c\/li\u003e\n\u003cli\u003eVerify that replacement units retain the 51454475-100 RAM charger module specification to prevent memory loss during power cycles.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52668000665963,"sku":"8C-PCNT03 51454363-375","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-8c-pcnt03-51454363-375-series-8-c300-controller-j1hvetizyiv_5b36e41d-9839-42e6-aee9-0f34bbe8a9b7.jpg?v=1765504998"},{"product_id":"honeywell-8c-pcnt05-51454363-275-series-8-c300-controller-module","title":"Honeywell 8C-PCNT05 51454363-275 Series 8 C300 Controller Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell 8C-PCNT05\u003c\/strong\u003e (Part Number \u003cstrong\u003e51454363-275\u003c\/strong\u003e) is a \u003cstrong\u003eSeries 8 C300v5 Controller Module\u003c\/strong\u003e engineered for continuous control strategy execution, complex process loops, and high-throughput field communication within the Honeywell Experion PKS system architecture. Built on dual-core processing hardware, this fifth-generation C300 controller significantly expands execution resources and communication throughput compared to legacy C300v3 hardware.\u003c\/p\u003e\n\u003cp\u003eOperating within the Honeywell Control Execution Environment (CEE), the \u003cstrong\u003eHoneywell 8C-PCNT05 51454363-275\u003c\/strong\u003e provides 32 MB of CEE user memory and 9000 execution units for intensive process logic, loop execution, and system-wide peer-to-peer data distribution. The module features factory conformal coating (coated 5, 6) to protect internal circuit assemblies against aggressive atmospheric conditions, chemical gases, and moisture encountered in demanding process control environments.\u003c\/p\u003e\n\u003cp\u003eThe unit connects directly to standard Series 8 mounting carriers, interfacing seamlessly across Fault Tolerant Ethernet (FTE) control networks. Supported on Experion PKS software releases R520.2 and onwards, the controller pairs with the dedicated 50182539-001 RAM charger module to ensure non-volatile retention of control configurations during main power supply interruptions.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual-Core Processing Hardware\u003c\/strong\u003e: Built with a dual-core architecture delivering 9000 processing execution units for high-demand control algorithms and communications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExpanded CEE Memory Capacity\u003c\/strong\u003e: Features 32 MB of dedicated CEE user memory for large-scale control strategy storage, function blocks, and sequential operations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnhanced Peer Communication\u003c\/strong\u003e: Supports up to 8 Peer Gateway Module (PGM) connections per C300 node for scalable network architecture expansion.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Data Access Rate\u003c\/strong\u003e: Achieves an overall display data access response rate of 4000 PPS and a peer communication rate of 2000 PPS.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePeer Initiator and Target Capacity\u003c\/strong\u003e: Delivers up to 2000 PPS incoming initiator pull\/get subscribe rates and 2000 PPS outgoing target publish rates.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Density Update Rates\u003c\/strong\u003e: Handles up to 200 peer capacity at 100 ms, 400 at 200 ms, 1000 at 500 ms, and 2000 at 1 sec update choices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDedicated Power Backup\u003c\/strong\u003e: Designed to pair with the 50182539-001 RAM charger module to protect runtime data during power interruptions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConformal Coated Protection\u003c\/strong\u003e: Factory conformal coating (coated 5, 6) safeguards electronic components in corrosive and harsh industrial atmospheres.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eExperion PKS Process Control\u003c\/strong\u003e: Central control processing engine executing continuous loops, complex interlocks, and batch recipes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLarge-Scale Plant Automation\u003c\/strong\u003e: Distributed control operations across chemical, refining, petrochemical, and power generation facilities requiring high tag counts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Speed Controller Networking\u003c\/strong\u003e: Peer-to-peer real-time data exchange across multiple C300 controller nodes via Fault Tolerant Ethernet (FTE).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcess Subsystem Integration\u003c\/strong\u003e: Managing high-density Series 8 I\/O modules, smart transmitters, and fieldbus interfaces.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003e8C-PCNT05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e51454363-275\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardware Generation\u003c\/td\u003e\n\u003ctd\u003eC300v5 (Series 8)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Coating\u003c\/td\u003e\n\u003ctd\u003eFactory Conformal Coating (Coated 5, 6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDedicated RAM Charger\u003c\/td\u003e\n\u003ctd\u003e50182539-001 (Required for RAM backup)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003e8C-PCNT05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e51454363-275\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eSeries 8 C300 Controller Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlatform \/ System\u003c\/td\u003e\n\u003ctd\u003eExperion PKS \/ Experion LX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardware Generation\u003c\/td\u003e\n\u003ctd\u003eC300v5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurface Protection\u003c\/td\u003e\n\u003ctd\u003eConformal Coated (Coated 5, 6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eProcessing \u0026amp; Memory\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor Architecture\u003c\/td\u003e\n\u003ctd\u003eDual Core\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessing Execution Units\u003c\/td\u003e\n\u003ctd\u003e9000 Us (Control \/ Execution)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal CEE User Memory\u003c\/td\u003e\n\u003ctd\u003e32 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRAM Charger Backup Module\u003c\/td\u003e\n\u003ctd\u003e50182539-001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eCommunication Performance\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PGM Connections per C300\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Data Access Response Rate\u003c\/td\u003e\n\u003ctd\u003e4000 PPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeer Data Access Response Rate\u003c\/td\u003e\n\u003ctd\u003e2000 PPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Initiator Pull\/Get Rate\u003c\/td\u003e\n\u003ctd\u003e2000 PPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Target Publish Rate\u003c\/td\u003e\n\u003ctd\u003e2000 PPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeer-to-Peer Execution Capacity\u003c\/td\u003e\n\u003ctd\u003e200 @ 100 ms, 400 @ 200 ms, 1000 @ 500 ms, 2000 @ 1 sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported FTE Switches\u003c\/td\u003e\n\u003ctd\u003eCisco 9200 (and qualified series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eSoftware Compatibility\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Experion Release\u003c\/td\u003e\n\u003ctd\u003eExperion PKS \/ LX R520.2 and onwards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarrier Edge Connector\u003c\/td\u003e\n\u003ctd\u003eDual backplane connection for attachment to Series 8 carrier assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFTE Network Interface\u003c\/td\u003e\n\u003ctd\u003eRedundant network routing over Fault Tolerant Ethernet infrastructure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRAM Charger Interface\u003c\/td\u003e\n\u003ctd\u003eDedicated header connection for the 50182539-001 RAM charger unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eInspect the 8C-PCNT05 module and carrier assembly to ensure slot contacts are clean and free of debris.\u003c\/li\u003e\n\u003cli\u003eIsolate power to the Series 8 mounting carrier before physically installing or replacing controller hardware.\u003c\/li\u003e\n\u003cli\u003eAlign the module's edge connectors with the designated C300 slot on the Series 8 carrier.\u003c\/li\u003e\n\u003cli\u003ePush the unit firmly into the carrier until the mechanical retaining latch fully engages.\u003c\/li\u003e\n\u003cli\u003eConnect the 50182539-001 RAM charger unit to the dedicated backup terminal on the controller.\u003c\/li\u003e\n\u003cli\u003eVerify redundant Fault Tolerant Ethernet (FTE) cabling connections to qualified Cisco 9200 switch ports.\u003c\/li\u003e\n\u003cli\u003eApply system power and monitor diagnostic LEDs during system initialization and boot sequence.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eConfiguration \/ Commissioning \/ Replacement Guidelines\u003c\/h3\u003e\n\u003ch4\u003eConfiguration Guidelines\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eProgram and configure control strategies using Honeywell Control Builder on Experion PKS release R520.2 or higher.\u003c\/li\u003e\n\u003cli\u003eAssign unique FTE node addresses and verify subnet settings prior to performing initial strategy downloads.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCommissioning Recommendations\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eMonitor CEE user memory consumption within Control Builder to optimize block assignments within the 32 MB limit.\u003c\/li\u003e\n\u003cli\u003eVerify peer-to-peer publication rates and PGM connection paths across configured controller nodes.\u003c\/li\u003e\n\u003cli\u003eCheck charging voltage status for the connected 50182539-001 RAM charger to ensure battery health.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eReplacement Recommendations\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCross-Generational Redundancy Constraint\u003c\/strong\u003e: The 8C-PCNT05 (C300v5) module cannot be paired in a redundant set with an 8C-PCNT03 (C300v3) module, as different hardware generations will not synchronize redundancy states.\u003c\/li\u003e\n\u003cli\u003ePerform a full system database and parameter backup in Control Builder before removing an existing controller module.\u003c\/li\u003e\n\u003cli\u003eAlways ensure the replacement 8C-PCNT05 unit is installed with the correct 50182539-001 RAM charger model rather than legacy charger units.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52668024684907,"sku":"8C-PCNT05 51454363-275","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-8c-pcnt05-51454363-275-controller-module-kgiqxif0a1y_2584baf8-a696-449a-98c5-56fc50affb76.jpg?v=1765505257"},{"product_id":"honeywell-experion-pks-8c-pcnt03-c300-control-processor","title":"Honeywell Experion PKS 8C-PCNT03 C300 Control Processor","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"citation-539\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003eHoneywell 8C-PCNT03 (8CPCNT03)\u003c\/strong\u003e\u003cspan class=\"citation-539\"\u003e\u003cspan\u003e \u003c\/span\u003eis the modern standard Control Processor for the\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003eExperion PKS (Process Knowledge System) Series 8\u003c\/strong\u003e\u003cspan class=\"citation-539 citation-end-539\"\u003e\u003cspan\u003e \u003c\/span\u003eplatform.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eIt serves as the successor to the 8C-PCNT02, offering enhanced processing power and expanded memory while maintaining full backward compatibility with all previous Experion LX and PlantCruise releases.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-538\"\u003eAs the \"brain\" of the Series 8 system, the\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e8C-PCNT03\u003c\/strong\u003e\u003cspan class=\"citation-538 citation-end-538\"\u003e\u003cspan\u003e \u003c\/span\u003eexecutes the deterministic Control Execution Environment (CEE), managing complex regulatory control, batch sequences, and fast-logic strategies.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-537\"\u003eThis version is factory-shipped with a\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003eG3 conformal coating\u003c\/strong\u003e\u003cspan class=\"citation-537 citation-end-537\"\u003e, providing the highest level of protection against corrosive atmospheric contaminants (such as Hydrogen Sulfide and Chlorine), making it the primary choice for global chemical, oil, and gas operations.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"citation-536\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e8C-PCNT03\u003c\/strong\u003e\u003cspan class=\"citation-536 citation-end-536\"\u003e\u003cspan\u003e \u003c\/span\u003earchitecture is designed for extreme reliability and high-speed data processing.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-535\"\u003e\u003c\/span\u003e\u003cstrong\u003eDual Processor Architecture\u003c\/strong\u003e\u003cspan class=\"citation-535 citation-end-535\"\u003e: Utilizes a high-performance multi-processor design (typically Dual ARM Cortex-A9) to ensure fast execution times and deterministic scheduling.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-534\"\u003e\u003c\/span\u003e\u003cstrong\u003eExpanded Memory\u003c\/strong\u003e\u003cspan class=\"citation-534 citation-end-534\"\u003e: Equipped with 512MB RAM and 1GB Flash memory, providing ample space for large-scale control strategies and extensive diagnostic logging.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-533\"\u003e\u003c\/span\u003e\u003cstrong\u003eG3 Conformal Coating\u003c\/strong\u003e\u003cspan class=\"citation-533 citation-end-533\"\u003e: Specifically treated to meet ISA S71.04 Class G3 standards for protection against corrosive environments.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-532\"\u003e\u003c\/span\u003e\u003cstrong\u003eRedundancy Ready\u003c\/strong\u003e\u003cspan class=\"citation-532 citation-end-532\"\u003e: Supports 1-to-1 hardware redundancy.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eWhen paired with a second 8C-PCNT03 on a redundant IOTA, it provides \"bumpless\" failover in the event of a primary processor fault.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-531\"\u003e\u003c\/span\u003e\u003cstrong\u003eIntegrated Communication\u003c\/strong\u003e\u003cspan class=\"citation-531 citation-end-531\"\u003e: Features dual FTE (Fault Tolerant Ethernet) ports for high-security network integration and dual I\/O Link ports for controlling up to 1024 I\/O points.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8C-PCNT03\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eExperion PKS Series 8\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProcessor Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eC300 Control Processor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eG3 Conformal Coated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMemory\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e512MB RAM \/ 1GB Flash\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eExecution Period\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50 ms to 2000 ms (Configurable)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40°C to 70°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVertical Series 8 IOTA (8C-TCNTA1)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCE, UL, FM Class I Div 2, ATEX Zone 2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.0 kg (Net) \/ 3.0 kg (Shipping)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 8C-PCNT03 compatible with my existing 8C-PCNT02 configuration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The 8C-PCNT03 is the direct replacement for the 8C-PCNT02. It can be installed on the same IOTA and is compatible with all current and previous Experion software releases.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between 8C-PCNT03 and 8C-PCNT05?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-PCNT03\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports both new and legacy Experion releases, making it ideal for maintenance and upgrades of existing systems. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-PCNT05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis the newest version (V5) and only supports Experion R520 and later; notably, the 03 and 05 versions are not interoperable in a redundant pair.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this controller support peer-to-peer communication?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The C300 CEE supports high-speed peer-to-peer communication with other C300 controllers over the FTE network, as well as communication with specialty modules like Foundation Fieldbus and Profibus.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUpgrade Note:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen replacing an older 8C-PCNT02 with an 8C-PCNT03 in a redundant pair, it is recommended to eventually replace both units to the same hardware revision to ensure identical execution timing and memory handling, although they can operate together during the migration period.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNetwork Wiring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUse only Honeywell-certified shielded Ethernet cables for FTE connections. Ensure that the \"Yellow\" and \"Green\" cables are connected to their respective ports on the IOTA to maintain the integrity of the Fault Tolerant Ethernet logic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 8C-PCNT03 relies on the Series 8 vertical design for natural convection. Ensure the cabinet has sufficient ventilation and that the 150 mm clearance rule is observed above and below the IOTA row to prevent the processor from overheating.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52668027240811,"sku":"8C-PCNT03","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-8c-pcnt03-series-8-c300-controller-gcrri2ue45p_ed94f917-8724-426a-8306-1db1b7d64423.jpg?v=1765505290"},{"product_id":"honeywell-experion-pks-8c-tdoda1-51307149-175-digital-output-iota","title":"Honeywell Experion PKS 8C-TDODA1 (51307149-175) Digital Output IOTA","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell 8C-TDODA1 (51307149-175)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a 32-channel Digital Output Termination Assembly (IOTA) designed for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eExperion PKS Series 8\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eI\/O platform. This \"Single\" IOTA serves as the mounting base and field wiring interface for a single\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-PDODA1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDigital Output module. It is engineered to drive 24 VDC discrete field devices such as solenoid valves, relays, and indicator lamps. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-TDODA1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures the signature Series 8 vertical design, which significantly reduces the cabinet footprint while enhancing thermal management through natural convection. This specific version (51307149-175) is factory-treated with a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eG3 conformal coating\u003c\/strong\u003e, providing a critical layer of protection against moisture and corrosive atmospheric elements commonly found in industrial processing environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-TDODA1 (51307149-175)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides a ruggedized electrical interface for discrete control.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e32-Channel Single-Ended Interface\u003c\/strong\u003e: Accommodates 32 digital output channels, allowing for high-density wiring and simplified common-return routing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eG3 Conformal Coating\u003c\/strong\u003e: The \"175\" suffix indicates compliance with ISA S71.04 Class G3, protecting the PCB and components from corrosive gases like Hydrogen Sulfide (H2S) and Chlorine (Cl2).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVertical Series 8 Form Factor\u003c\/strong\u003e: Fits onto a standard Series 8 carrier, facilitating an efficient \"chimney-effect\" airflow that keeps the electronic module cool.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBuilt-in Circuit Protection\u003c\/strong\u003e: Designed to work with the I\/O module’s diagnostic capabilities, including short-circuit protection and load monitoring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaintenance-Friendly Design\u003c\/strong\u003e: Allows for the electronic I\/O module to be replaced (\"hot-swapped\") without disconnecting the field wiring terminals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8C-TDODA1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e51307149-175\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eExperion PKS Series 8\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eI\/O Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDigital Output (32-Channel)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC Nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCoating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eG3 Conformal Coated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8C-PDODA1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to 70 Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTerminal Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCompression Screw Terminals\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.60 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this IOTA in a redundant configuration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The 8C-TDODA1 is a \"Single\" IOTA, meaning it has only one slot for an I\/O module. For redundant DO applications where two modules back up each other, you must use the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-TDODB1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eredundant IOTA.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the maximum current per channel?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the module can drive typical 24 VDC solenoids, the total current capacity is limited. For high-current loads or high-frequency switching, it is highly recommended to use interposing relays to prevent thermal stress on the IOTA and module.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow is the field power provided to the outputs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eField excitation power (24 VDC) is usually supplied through the Series 8 carrier busbar. The IOTA then distributes this power to the individual channels based on the commands from the C300 controller.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring Precautions:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUse ferrules on all field wiring to ensure reliable contact and prevent stray wire strands from shorting adjacent terminals in the high-density terminal block.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure the IOTA is firmly snapped into the carrier and that the carrier itself is properly bonded to the instrument ground bar. Inadequate grounding can lead to intermittent diagnostic errors and susceptibility to electromagnetic interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFuse Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMonitor the \"Blown Fuse\" diagnostics in the Experion software. If a fuse-protected circuit is used, identify and rectify the field-side short circuit before replacing the module or resetting the system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Spacing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMaintain the manufacturer-specified 150 mm clearance above and below the IOTA row to ensure adequate cooling. Overheating is a primary cause of shortened electronic lifespan in high-density DC cabinets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52668027765099,"sku":"8C-TDODA1 51307149-175","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-8c-tdoda1-51307149-175-digital-output-bussed-irxllnpltok_da87522a-b045-4c95-88b5-ba132f5cec30.jpg?v=1765505296"},{"product_id":"honeywell-8u-pwsp01-cn-experion-lx-series-8-20a-power-supply-module","title":"Honeywell 8U-PWSP01-CN Experion LX Series 8 20A Power Supply Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell 8U-PWSP01-CN\u003c\/strong\u003e is a 20A power supply module designed for providing regulated DC system power in Experion LX Series 8 control environments. Operating on an AC input voltage rating of 120\/240 VAC, it converts line utility power into the stabilized +24 VDC output required by C300 controllers, Series 8 Input\/Output modules, and associated I\/O Termination Assemblies (IOTAs).\u003c\/p\u003e\n\u003cp\u003eAs a core element of the Experion LX Series 8 power subsystem, the \u003cstrong\u003e8U-PWSP01-CN\u003c\/strong\u003e mounts within the dedicated Series 8 metal power rack assembly. It transfers system voltage through top-mounted header boards to the cabinet power distribution network. In dual-access cabinet configurations, power systems can be deployed across both cabinet sides to maintain continuous operational coverage across all installed control hardware.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDelivers +24 VDC output with up to 20A current capacity to feed Series 8 I\/O modules and C300 control hardware.\u003c\/li\u003e\n\u003cli\u003eOperates on 120\/240 VAC line input voltage via terminal block connections for flexible power distribution.\u003c\/li\u003e\n\u003cli\u003eInstalls directly into the Series 8 power supply metal chassis, connecting to top header boards for cabinet-wide power distribution.\u003c\/li\u003e\n\u003cli\u003eSupports redundant dual-power module configurations when paired with a second 20A unit in the power rack.\u003c\/li\u003e\n\u003cli\u003eFeeds power directly into the cabinet distribution subsystem without requiring individual external DC power wiring runs to IOTAs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eExperion LX Series 8 cabinet power distribution subsystems requiring primary or redundant 24 VDC power rails.\u003c\/li\u003e\n\u003cli\u003eCentralized +24 VDC power distribution for Honeywell C300 controllers, Control Firewalls, and Series 8 I\/O modules.\u003c\/li\u003e\n\u003cli\u003eContinuous processing, batch automation, and industrial control cabinets operating within Experion LX hardware architecture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e8U-PWSP01-CN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eExperion LX Series 8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Rating\u003c\/td\u003e\n\u003ctd\u003e120 \/ 240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Rating\u003c\/td\u003e\n\u003ctd\u003e+24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current Rating\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Rack Interface\u003c\/td\u003e\n\u003ctd\u003eMetal Power System Rack (Part Number 51154886)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDistribution Interface\u003c\/td\u003e\n\u003ctd\u003eHeader Board (Part Number 51307186)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eVerify that incoming AC line voltage matches the 120\/240 VAC rating before installing the 8U-PWSP01-CN module into the cabinet.\u003c\/li\u003e\n\u003cli\u003eEnsure line power feeder breakers are isolated and locked out prior to wiring the cabinet AC terminal block.\u003c\/li\u003e\n\u003cli\u003eMount the power supply module securely into the designated metal power supply rack inside the Series 8 cabinet.\u003c\/li\u003e\n\u003cli\u003eConnect user-supplied AC power conductors (L1, L2, and Safety Ground) through the cabinet entry port to the AC terminal block.\u003c\/li\u003e\n\u003cli\u003eVerify protective earth ground connections to ensure system safety and high electrical noise immunity.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eConfiguration and Commissioning Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eConduct continuity checks across the +24 VDC power distribution header board to verify there are no field short circuits.\u003c\/li\u003e\n\u003cli\u003eApply AC line power via the cabinet Circuit Breaker Box and measure the output at the header board to verify stable +24 VDC supply.\u003c\/li\u003e\n\u003cli\u003eInspect status LEDs on the power supply module to confirm proper initialization and power subsystem health.\u003c\/li\u003e\n\u003cli\u003eVerify proper cabinet ventilation and fan assembly operation to maintain acceptable operating ambient temperature limits.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52668028748139,"sku":"8U-PWSP01-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-8u-pwsp01-cn-power-supply-module-ynl1mfeu1sw_5f039fb3-0f05-456f-a854-171a8b9b8f68.jpg?v=1765505302"},{"product_id":"honeywell-experion-pks-8c-paona1-51454469-175-analog-output-module","title":"Honeywell Experion PKS 8C-PAONA1 (51454469-175) Analog Output Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell 8C-PAONA1 (51454469-175)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-precision 16-channel Analog Output (AO) module designed for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eExperion PKS Series 8\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eI\/O architecture. As a core component of the C300 control system, this module converts digital control algorithms into accurate 4-20 mA analog signals to drive final control elements such as valve positioners, variable speed drives, and dampers. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-PAONA1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis specifically engineered for high-density deployments, featuring the Series 8 slim vertical form factor that enhances natural convection cooling. This \"175\" variant comes standard with a factory-applied G3 conformal coating, providing essential protection against corrosive atmospheric contaminants. By ensuring stable signal delivery in harsh industrial environments, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-PAONA1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eplays a vital role in maintaining process stability and reducing the total cost of ownership through enhanced hardware durability.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-PAONA1 (51454469-175)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis defined by its ruggedized electronics and seamless integration with the Series 8 I\/O Link.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e16-Channel Capacity\u003c\/strong\u003e: Supports up to 16 independent analog loops per module, maximizing I\/O density within the control cabinet.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNon-HART Signal Path\u003c\/strong\u003e: Dedicated to standard 4-20 mA analog modulation, offering a streamlined and cost-effective solution for control loops that do not require digital HART diagnostics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eG3 Conformal Coating\u003c\/strong\u003e: The 51454469-175 hardware revision is specifically treated to resist corrosion from H2S, Cl2, and ammonia, meeting ISA S71.04 Class G3 standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGalvanic Isolation\u003c\/strong\u003e: Provides comprehensive electrical isolation between field wiring and the internal system bus, protecting the C300 controller from field transients and ground loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundancy Ready\u003c\/strong\u003e: Fully compatible with redundant Series 8 IOTAs, allowing for seamless bumpless transfer in high-availability control applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8C-PAONA1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePart Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e51454469-175\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eExperion PKS Series 8\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModule Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAnalog Output (Non-HART)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 to 20 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNumber of Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to 70 Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProtection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eG3 Conformal Coated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5.8 Watts Maximum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.45 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15.20 x 9.80 x 4.20 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan I replace an 8C-PAONA1 with an 8C-PAOHA1 (HART version)?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the 8C-PAOHA1 is generally backward compatible and can reside on the same IOTA. However, you must update the module configuration in the Experion Control Builder to enable the HART features.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the \"Non-HART\" designation mean for my field devices?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt means this module only transmits the 4-20 mA analog signal. If you have \"Smart\" valve positioners, they will still move correctly based on the current, but the DCS will not be able to read digital diagnostic data or valve signatures from them.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I verify the G3 coating on this part?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe part number suffix \"175\" is the primary indicator of the G3 conformal coating. Physically, the board will have a slight uniform sheen compared to non-coated \"100\" series boards when viewed under reflected light.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLoad Impedance Verification:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 8C-PAONA1 is designed to drive loads up to a maximum of 600 Ohms. Before commissioning, calculate the total loop resistance including the field wire run and the positioner impedance. High-resistance loops can cause the output to saturate or trigger \"Output Open\" alarms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHot-Swap Protocol:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module supports Removal and Insertion Under Power (RIUP). In a redundant configuration, ensure the \"OK\" LED on the partner module is solid green before removing the module being serviced to prevent a process upset.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring and Noise Suppression:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo maintain signal integrity, use individual shielded twisted-pair cables for each AO channel. The shields must be terminated at the IOTA's ground bar to prevent electromagnetic interference from inducing \"jitter\" in the valve control signal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52668031205739,"sku":"8C-PAONA1 51454469-175","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-8c-paona1-51454469-175-analog-output-module-pr3lnm2gi33_9db50288-9e32-48b9-bb61-3adc7964f986.jpg?v=1765505321"},{"product_id":"honeywell-experion-pks-8c-tdila1-51307141-175-digital-input-iota","title":"Honeywell Experion PKS 8C-TDILA1 (51307141-175) Digital Input IOTA","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell 8C-TDILA1 (51307141-175)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density Digital Input Termination Assembly (IOTA) belonging to the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eExperion PKS Series 8\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eI\/O family. This module acts as the physical and electrical foundation for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-PDILA1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDigital Input module, providing 32 channels of discrete signal acquisition. It is designed to interface with field contacts such as push-buttons, limit switches, and motor starter auxiliary contacts. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-TDILA1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis engineered with the signature Series 8 vertical orientation to optimize cabinet space and enhance thermal management through natural convection. This specific variant, identified by part number\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e51307141-175\u003c\/strong\u003e, features a factory-applied G3 conformal coating, making it resilient against corrosive gases and high-humidity environments typical in oil refineries and chemical processing plants.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-TDILA1 (51307141-175)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003earchitecture is optimized for high-speed signal processing and simplified field maintenance.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e32-Channel Single-Ended Interface\u003c\/strong\u003e: Provides terminal connections for up to 32 discrete inputs, sharing a common return to maximize wiring density.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eG3 Conformal Coating\u003c\/strong\u003e: The \"175\" suffix ensures the board is treated to withstand harsh environmental conditions, protecting against corrosion from Hydrogen Sulfide (H2S) and Chlorine (Cl2).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVertical Form Factor\u003c\/strong\u003e: Mounts onto a Series 8 carrier, allowing for a \"slim\" I\/O profile that significantly reduces the overall footprint of the DCS cabinet.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Power Management\u003c\/strong\u003e: Distributes 24 VDC field excitation power to the input contacts while maintaining electrical isolation for the C300 controller.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Maintenance\u003c\/strong\u003e: The IOTA design allows for the replacement of the electronic I\/O module without disturbing the field wiring connected to the terminal blocks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8C-TDILA1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePart Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e51307141-175\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eExperion PKS Series 8\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eI\/O Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDigital Input (32-Channel)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC Nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCoating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eG3 Conformal Coated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eI\/O Module Compatibility\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8C-PDILA1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to 70 Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTerminal Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eScrew Compression Terminals\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.65 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12.00 x 30.00 x 11.00 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 8C-TDILA1 support redundant input module configurations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The 8C-TDILA1 is a \"Single\" IOTA, meaning it supports only one 8C-PDILA1 module. For redundant applications where two modules monitor the same 32 field points, you must use the redundant version, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-TDILB1\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat field excitation voltage does this IOTA provide?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis IOTA is designed for 24 VDC discrete inputs. The 24 VDC power is typically sourced from the system power supply through the Series 8 carrier bus and distributed to the field contacts via the IOTA terminals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this IOTA in a non-corrosive environment?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. While the G3 coating (51307141-175) is designed for harsh environments, it is fully compatible with standard control room environments. It provides an extra layer of protection against unexpected humidity or airborne contaminants.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eField Wiring Organization:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGiven the 32-channel density, use fine-stranded wire with ferrules for all connections to the compression terminals. Clear labeling and organized wire ducting are essential to prevent cross-talk and facilitate future troubleshooting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure the IOTA is properly snapped into the Series 8 carrier and that the carrier is bonded to the instrument earth bar. Proper grounding is critical for the internal surge protection circuitry to function correctly during field-side transients.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Clearances:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMaintain the recommended 150 mm clearance above and below the IOTA row. The vertical design relies on the \"chimney effect\" for cooling; obstructing airflow can lead to localized hotspots and premature failure of the inserted I\/O module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52668031304043,"sku":"8C-TDILA1 51307141-175","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-8c-tdila1-51307141-175-input-module-hhpp2chb3tf_64736da3-58c9-4b6e-97d0-b96456e712d1.jpg?v=1765505322"},{"product_id":"honeywell-tk-mdp081-51404351-175-experion-lx-high-speed-pulse-input-module","title":"Honeywell TK-MDP081 51404351-175 Experion LX High Speed Pulse Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell TK-MDP081\u003c\/strong\u003e (Part Number \u003cstrong\u003e51404351-175\u003c\/strong\u003e) is a conformal coated, single-slot High Speed Pulse Input (PI) specialty module developed for the Honeywell Experion Series-A Chassis I\/O (CIOM-A) platform. Designed to provide accurate pulse counting and frequency processing, the module features 8 high-speed counter input channels alongside 2 dedicated On\/Off outputs. It acts as a specialized process interface for turbine meters, flowmeters, tachometers, and other pulse-generating field equipment within Honeywell C200 and C200E control systems.\u003c\/p\u003e\n\u003cp\u003eEngineered to operate seamlessly across Experion control networks, the \u003cstrong\u003eTK-MDP081\u003c\/strong\u003e communicates across the chassis backplane and integrates into the system topology via ControlNet interface modules. Its onboard counting capabilities process high-frequency pulse trains locally, alleviating CPU processing overhead and ensuring precise totalization, rate measurement, and real-time control response.\u003c\/p\u003e\n\u003cp\u003eAs part of the Experion Series-A chassis family, the module mounts directly into any available slot position within 4-, 7-, 10-, 13-, or 17-slot Series-A chassis. Built-in conformal coating ensures long-term operational integrity in harsh industrial environments containing airborne corrosive contaminants.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Density Channel Design:\u003c\/strong\u003e Equipped with 8 high-speed counter inputs and 2 discrete On\/Off outputs in a single-slot form factor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConformal Coating Protection:\u003c\/strong\u003e Comes standard with factory conformal coating (TK prefix) to withstand ISA Class G3 harsh environmental conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Integration:\u003c\/strong\u003e Operates within the Experion CIOM-A chassis family and interfaces directly with C200 and C200E control processors via ControlNet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Termination Options:\u003c\/strong\u003e Uses a standard 36-pin removable terminal block (TC-TBCH) or pre-wired Remote Terminal Panel (RTP) cable assemblies for efficient cabinet wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHot-Swappable Maintenance:\u003c\/strong\u003e Supports Removal and Insertion Under Power (RIUP) in ordinary (non-hazardous) locations to minimize operational downtime during service.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlow Totalization \u0026amp; Rate Monitoring:\u003c\/strong\u003e Direct interface to pulse-output liquid\/gas flowmeters and turbine meters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRotational Speed \u0026amp; Velocity Tracking:\u003c\/strong\u003e Processing tachometer and encoder pulse feedback on rotating machinery, pumps, and motors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBatching \u0026amp; Dosing Control:\u003c\/strong\u003e High-speed event counting combined with onboard discrete outputs for direct valve or actuator control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePulse Signal Processing:\u003c\/strong\u003e Accumulation and frequency evaluation of high-speed field signals in industrial process control.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003eTK-MDP081\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e51404351-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eHigh Speed Pulse Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlatform\u003c\/td\u003e\n\u003ctd\u003eExperion LX \/ Experion PKS Series-A I\/O (CIOM-A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003eSingle-wide chassis slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConformal Coating\u003c\/td\u003e\n\u003ctd\u003eYes (TK Series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquivalent Allen-Bradley Model\u003c\/td\u003e\n\u003ctd\u003e1756-IJ4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eI\/O Capacity \u0026amp; Features\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Speed Counter Inputs\u003c\/td\u003e\n\u003ctd\u003e8 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete On\/Off Outputs\u003c\/td\u003e\n\u003ctd\u003e2 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRequired Terminal Block\u003c\/td\u003e\n\u003ctd\u003e36-pin (TC-TBCH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eEnvironmental\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 degC (32 to 140 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 degC (-40 to 185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95% noncondensing (up to 40 degC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCorrosive Atmosphere\u003c\/td\u003e\n\u003ctd\u003eANSI\/ISA-S71.04-1985 Class G1, G2, and G3 (Harsh)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd\u003e-300 to +3000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Shock (Operating)\u003c\/td\u003e\n\u003ctd\u003e5 g max., 30 ms duration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Shock (Transportation)\u003c\/td\u003e\n\u003ctd\u003e20 g max., 30 ms duration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration (Operating)\u003c\/td\u003e\n\u003ctd\u003e10 to 60 Hz, 0.5 g max., 0.1 inch displacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eWiring Option\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eComponent\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOption 1: Direct Wiring\u003c\/td\u003e\n\u003ctd\u003eTC-TBCH\u003c\/td\u003e\n\u003ctd\u003e36-pin removable terminal block supporting 1 wire @ 16-22 AWG (0.64-1.30 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOption 2: Pre-Wired Cable\u003c\/td\u003e\n\u003ctd\u003e1492-HWCAB###\u003c\/td\u003e\n\u003ctd\u003ePre-wired cable with Honeywell slide-on cover connecting module to Remote Terminal Panel (RTP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOption 2: Remote Terminal Panel\u003c\/td\u003e\n\u003ctd\u003e1492-IFM \/ 1492-RIFM\u003c\/td\u003e\n\u003ctd\u003eDIN-rail mounted terminal panel for field wiring interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003ePre-Installation Inspection:\u003c\/strong\u003e Verify the module part number (\u003cstrong\u003eTK-MDP081\u003c\/strong\u003e \/ \u003cstrong\u003e51404351-175\u003c\/strong\u003e) and inspect the board and pins for physical damage prior to installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower \u0026amp; Backplane Check:\u003c\/strong\u003e Ensure the Series-A power supply capacity (24 VDC, 5 VDC, 3.3 VDC, and 1.2 VDC outputs) is calculated to support all installed modules without exceeding the 70 W \/ 75 W total output limit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Slot Insertion:\u003c\/strong\u003e Align the single-wide module with the guide rails of the target slot in the CIOM-A chassis and push firmly until the module is securely latched into the backplane connector.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Termination:\u003c\/strong\u003e Connect field pulse signals to either the 36-pin TC-TBCH terminal block or the pre-wired Allen-Bradley 1492 RTP cable assembly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding \u0026amp; Grounding:\u003c\/strong\u003e Route pulse input signal cables separately from high-voltage AC lines to prevent electrical noise interference on high-speed counting lines. Ensure shield wires are properly grounded at designated panel tie-points.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHot Swapping (RIUP):\u003c\/strong\u003e Removal and insertion under power is permitted in non-hazardous locations. Ensure hot-work permits are obtained if operating in Class I, Division 2 hazardous areas.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eStandard \/ Classification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety \/ Industrial Control\u003c\/td\u003e\n\u003ctd\u003eUL 508 Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous Location\u003c\/td\u003e\n\u003ctd\u003eClass I, Div 2, Groups A, B, C \u0026amp; D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEuropean Conformity\u003c\/td\u003e\n\u003ctd\u003eCE Mark (EN 50081-2 Emissions, EN 50082-2 Immunity)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC-Tick\u003c\/td\u003e\n\u003ctd\u003eAustralian Radiocommunications Act Section 182\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52668033991019,"sku":"TK-MDP081 51404351-175","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/TK-MDP081-51404351-175_004_1200x1200_efc57eaa-4f7a-4945-8e0b-690508aab891.jpg?v=1786886251"},{"product_id":"honeywell-experion-pks-8c-paona2-analog-output-module-non-hart","title":"Honeywell Experion PKS 8C-PAONA2 Analog Output Module (Non-HART)","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell 8C-PAONA2 (8CPAONA2)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance Analog Output (AO) module belonging to the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eExperion PKS Series 8\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eI\/O family. Engineered for precision and mission-critical reliability, this 16-channel module converts digital control commands from the C300 controller into standard 4-20 mA analog signals. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-PAONA2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis primarily used to drive final control elements such as pneumatic valve positioners, variable speed drives (VSD), and dampers. As a \"Series 8\" component, it features a vertical, slimline design that optimizes cabinet density and promotes natural thermal convection. This specific variant is the \"Non-HART\" version, providing a cost-effective solution for control loops where digital field device diagnostics are not required, while maintaining the rugged G3-level environmental protection standard in Honeywell's premium I\/O line.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-PAONA2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed to integrate seamlessly into the Experion PKS architecture, focusing on signal stability and hardware longevity.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e16-Channel Density\u003c\/strong\u003e: Provides 16 independent analog output channels, allowing for high-density I\/O configurations in a small physical footprint.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeries 8 Architecture\u003c\/strong\u003e: Designed to be \"plug-and-play\" with Series 8 IOTAs (Input Output Termination Assemblies), supporting both non-redundant and redundant configurations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eG3 Conformal Coating\u003c\/strong\u003e: The module is factory-treated with a conformal coating to protect internal circuitry against humidity and corrosive atmospheric contaminants (ISA S71.04 Class G3).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGalvanic Isolation\u003c\/strong\u003e: Features robust isolation between the I\/O Link (backplane) and the field-side electronics, preventing ground loops and protecting the C300 processor from field electrical faults.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFast Loop Response\u003c\/strong\u003e: Optimized for low-latency signal delivery, ensuring that control valve movements are synchronized with the DCS PID logic for stable process modulation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; height: 254.719px;\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\" style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.5312%; height: 19.5938px;\"\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.6116%; height: 19.5938px;\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.5312%; height: 19.5938px;\"\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.6116%; height: 19.5938px;\"\u003e\u003cspan\u003e8C-PAONA2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.5312%; height: 19.5938px;\"\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.6116%; height: 19.5938px;\"\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.5312%; height: 19.5938px;\"\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.6116%; height: 19.5938px;\"\u003e\u003cspan\u003eExperion PKS Series 8\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.5312%; height: 19.5938px;\"\u003e\u003cspan\u003eModule Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.6116%; height: 19.5938px;\"\u003e\u003cspan\u003eAnalog Output (Non-HART)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.5312%; height: 19.5938px;\"\u003e\u003cspan\u003eNumber of Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.6116%; height: 19.5938px;\"\u003e\u003cspan\u003e16 Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.5312%; height: 19.5938px;\"\u003e\u003cspan\u003eOutput Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.6116%; height: 19.5938px;\"\u003e\u003cspan\u003e4 to 20 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.5312%; height: 19.5938px;\"\u003e\u003cspan\u003eResolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.6116%; height: 19.5938px;\"\u003e\u003cspan\u003e12-bit Minimum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.5312%; height: 19.5938px;\"\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.6116%; height: 19.5938px;\"\u003e\u003cspan\u003e-40 to 70 Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.5312%; height: 19.5938px;\"\u003e\u003cspan\u003eProtection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.6116%; height: 19.5938px;\"\u003e\u003cspan\u003eG3 Conformal Coated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.5312%; height: 19.5938px;\"\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.6116%; height: 19.5938px;\"\u003e\u003cspan\u003e5.5 Watts Typical\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.5312%; height: 19.5938px;\"\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.6116%; height: 19.5938px;\"\u003e\u003cspan\u003e0.45 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 44.5312%; height: 19.5938px;\"\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 52.6116%; height: 19.5938px;\"\u003e\u003cspan\u003e15.00 x 10.00 x 4.00 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan the 8C-PAONA2 be used to communicate with HART-enabled valves?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the 8C-PAONA2 can drive a HART-enabled valve positioner using a standard 4-20 mA signal, it\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecannot\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eread or write digital HART data. For full HART pass-through and diagnostics, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-PAOHA1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodule must be used instead.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does this module handle a loss of communication with the controller?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 8C-PAONA2 features a configurable \"Fail-Safe\" state. In the event of an I\/O Link failure or controller shutdown, each channel can be programmed to Hold Last Value (HLV) or go to a pre-defined safe value (e.g., 0 mA or 4 mA).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this module compatible with older Series A or Series C IOTAs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The 8C-PAONA2 is strictly a Series 8 module and must be mounted on a Series 8 IOTA, such as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-TAOXA1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Single) or\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-TAOXB1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Redundant).\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Impedance Matching:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure that the total loop resistance (including field wiring and the actuator\/positioner impedance) does not exceed the module's maximum drive capability, typically 600 Ohms at 24 VDC. Exceeding this limit will result in \"Output Low\" errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHot-Swap Procedure:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module supports Removal and Insertion Under Power (RIUP). When replacing a module in a redundant pair, ensure the \"Secondary\" LED is stable before removing the \"Primary\" module to ensure a bumpless transfer of control.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShielding and Noise:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUse twisted-pair shielded cable for all 16 channels. The shield should be grounded at the IOTA's grounding bar. Proper shielding is critical to prevent electromagnetic interference (EMI) from inducing \"jitter\" in the 4-20 mA output signal, which can lead to premature mechanical wear on valve positioners.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52668035236203,"sku":"8C-PAONA2","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-8c-paona2-dcs-backplane-nkoilvcvcx2_ef231f8b-558f-431c-9001-1acf9869e5f7.jpg?v=1765505367"},{"product_id":"honeywell-experion-pks-8c-tdodb1-digital-output-redundant-iota","title":"Honeywell Experion PKS 8C-TDODB1 Digital Output Redundant IOTA","description":"\u003ch3 class=\"\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003eHoneywell 8C-TDODB1 (8CTDODB1)\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eis a high-availability Digital Output Termination Assembly (IOTA) designed for the\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003eExperion PKS Series 8\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eI\/O platform.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis \"Redundant\" IOTA is a critical infrastructure component that allows two\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003e8C-PDODA1\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eDigital Output modules to operate in a 1-out-of-2 (1oo2) configuration.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIn this setup,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe primary and secondary modules work in tandem; if the primary module fails,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe secondary module takes over control of the field devices instantaneously without a \"bump\" in the process.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003e8C-TDODB1\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eis primarily utilized in sectors requiring mission-critical safety and uptime,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003esuch as Emergency Shutdown (ESD) systems,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eturbine trip circuits,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand critical solenoid header controls in chemical and power plants.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003e8C-TDODB1\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eis engineered to provide a robust physical and electrical foundation for redundant digital control.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eRedundant Module Support\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eFeatures two dedicated slots for Digital Output modules,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003emanaging the synchronization and load-sharing logic between the two units.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003e32-Channel Density\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eSupports up to 32 individual digital output channels,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003etypically used for driving 24 VDC solenoids,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003erelays,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eor indicator lamps.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eG3 Conformal Coating\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eFactory-treated with a protective layer to ensure long-term reliability in environments with high humidity or corrosive gas concentrations (conforming to ISA G3 standards).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eVertical I\/O Design\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eUtilizes the Series 8 vertical mounting format,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ewhich promotes natural airflow for cooling and reduces the overall footprint within the control cabinet.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eIntegrated Blown Fuse Detection\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eProvides circuit protection and diagnostic feedback to the C300 controller,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eallowing operators to identify field-side wiring faults or short circuits immediately.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8C-TDODB1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eExperion PKS Series 8\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eI\/O Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDigital Output (Redundant)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eChannel Count\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e32 Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVoltage Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC Nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCoating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eG3 Conformal Coated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVertical Series 8 Carrier\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTerminal Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCompression Screw Terminals\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to 70 Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.75 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12.00 x 30.00 x 12.00 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 class=\"\"\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eCan I use only one module on the 8C-TDODB1 IOTA?\u003c\/strong\u003e\u003cspan class=\"\"\u003eYes.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eWhile the 8C-TDODB1 is designed for redundancy,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eit can operate with a single module.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eHowever,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe system will report a \"Redundancy Lost\" alarm until the second module is installed and synchronized.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eWhat is the difference between 8C-TDODA1 and 8C-TDODB1?\u003c\/strong\u003e\u003cspan class=\"\"\u003eThe 8C-TDODA1 is a \"Single\" IOTA,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003esupporting only one module with no hardware redundancy.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003e8C-TDODB1\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eis the \"Redundant\" version,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003efeaturing two module slots for high-availability applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eDoes this IOTA provide power to the field solenoids?\u003c\/strong\u003e\u003cspan class=\"\"\u003eThe IOTA distributes 24 VDC power from the cabinet busbar to the outputs.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eHowever,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe total current capacity is limited per channel.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eFor high-current solenoids,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003einterposing relays should be used to protect the IOTA circuitry.\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3 class=\"\"\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eRedundancy Cable Installation:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eEnsure the redundancy link between the two modules is securely seated.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eWithout this link,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe modules cannot synchronize their internal states,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eleading to independent operation and potential control conflicts.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eField Wiring Termination:\u003c\/strong\u003e\u003cspan\u003e When wiring the 32 channels,\u003c\/span\u003e\u003cspan\u003e use ferrules to prevent stray wire strands from causing short circuits between adjacent terminals.\u003c\/span\u003e\u003cspan\u003e Given the high density of the 8C-TDODB1,\u003c\/span\u003e\u003cspan\u003e cable management and clear labeling are essential for future troubleshooting.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding Requirements:\u003c\/strong\u003e\u003cspan\u003e The IOTA must be bonded to the instrument earth bar via the carrier's grounding system.\u003c\/span\u003e\u003cspan\u003e Proper grounding is vital for the correct operation of the blown-fuse detection circuitry and to prevent electromagnetic noise from affecting the I\/O Link communication.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52668035662187,"sku":"8C-TDODB1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-8c-tdodb1-digital-output-module-nto0msgjdle_0be4d2d8-53a4-4ee4-9ea3-94936ec0e1b4.jpg?v=1765505373"},{"product_id":"honeywell-experion-pks-8c-taoxa1-51307135-175-analog-output-iota","title":"Honeywell Experion PKS 8C-TAOXA1 (51307135-175) Analog Output IOTA","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell 8C-TAOXA1 (51307135-175)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-reliability Analog Output Termination Assembly (IOTA) belonging to the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eExperion PKS Series 8\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eI\/O family. As a fundamental component of the C300 control environment, this IOTA provides the physical mounting base and field wiring interface for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-PAOXA1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAnalog Output module. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-TAOXA1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed to support 16 channels of 4-20 mA signals, commonly used to drive control valves, actuators, and speed governors in critical process industries such as oil and gas, power generation, and pharmaceutical manufacturing. Its vertical form factor is a signature of the Series 8 design, engineered to promote natural convection cooling and minimize the footprint within high-density control cabinets.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-TAOXA1 (51307135-175)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003earchitecture is optimized for rapid installation and long-term signal integrity in demanding industrial settings.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e16-Channel Capacity\u003c\/strong\u003e: Provides dedicated screw terminal points for 16 analog output loops, supporting both redundant and non-redundant configurations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVertical Mounting Profile\u003c\/strong\u003e: Specifically designed for the Series 8 Slim chassis, allowing for efficient cable management and superior thermal dissipation compared to traditional horizontal racks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eG3 Conformal Coating\u003c\/strong\u003e: The 51307135-175 variant is factory-treated with a protective coating to withstand Class G3 harsh environments, preventing corrosion from H2S, Cl2, and other caustic gases.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Power Distribution\u003c\/strong\u003e: Manages the distribution of 24 VDC power from the cabinet bus to the inserted I\/O module and the field-side loop, ensuring consistent drive current across all 16 channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eField Wiring Interface\u003c\/strong\u003e: Features robust, high-density compression terminals that facilitate secure connections for field cabling, with integrated support for shield grounding.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8C-TAOXA1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePart Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e51307135-175\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eExperion PKS Series 8\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eI\/O Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAnalog Output (16-Channel)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCoating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eG3 Conformal Coated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eI\/O Module Compatibility\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8C-PAOXA1 \/ 8C-PAOYA1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to 70 Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVertical Series 8 Carrier\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTerminal Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eScrew Compression Terminals\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.55 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12.00 x 30.00 x 10.00 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 8C-TAOXA1 compatible with HART communication modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. While the IOTA is a passive termination assembly, it is designed to transparently pass HART digital data when paired with an Analog Output module that supports HART (such as the 8C-PAOHA1).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the significance of the 51307135-175 part number?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 175 suffix specifically denotes the G3 conformal coating. Standard, non-coated versions carry different suffixes. This version is required for any installation where the control room atmosphere is not strictly regulated for corrosive contaminants.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this IOTA for redundant AO module configurations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 8C-TAOXA1 is a non-redundant (Single) IOTA. For redundant applications where two modules back up one another on the same field wiring, you must use the redundant version of the IOTA (8C-TAOXB1).\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring Discipline\u003c\/strong\u003e: When connecting 4-20 mA loops to the 8C-TAOXA1, ensure that signal cables are kept separate from high-voltage AC lines. Use twisted-pair shielded cables and terminate the shield at the IOTA designated ground point to minimize electromagnetic interference (EMI) that can cause valve hunting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Seating\u003c\/strong\u003e: Before applying power, ensure the 8C-PAOXA1 module is fully seated onto the IOTA and the captive mounting screws are tightened. A loose module can cause intermittent Channel Fault or I\/O Link Failure alarms in the Experion System Status Display.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAtmospheric Protection\u003c\/strong\u003e: Since this is the 51307135-175 G3-coated version, ensure that when field wiring is completed, the cabinet entries are sealed. The coating protects the board, but terminal connections remain vulnerable to heavy oxidation if the cabinet is left open in a corrosive environment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52668040085867,"sku":"8C-TAOXA1 51307135-175","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-8c-taoxa1-51307135-175-analog-output-module-ee5lfji1kt3_bed50637-0f91-47a7-be5b-ee3622df234d.jpg?v=1765505433"},{"product_id":"honeywell-experion-pks-8c-pcnt02-c300-control-processor","title":"Honeywell Experion PKS 8C-PCNT02 C300 Control Processor","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"citation-486\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e8C-PCNT02 (8CPCNT02)\u003c\/strong\u003e\u003cspan class=\"citation-486 citation-end-486\"\u003e\u003cspan\u003e \u003c\/span\u003eis the high-performance centerpiece of the Honeywell Experion PKS (Process Knowledge System) Series 8 hardware platform.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-485\"\u003eAs an advanced\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003eC300 Control Processor\u003c\/strong\u003e\u003cspan class=\"citation-485 citation-end-485\"\u003e, this unit is engineered to execute complex control strategies, batch operations, and fast-logic requirements with absolute determinism.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-484\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e8C-PCNT02\u003c\/strong\u003e\u003cspan class=\"citation-484 citation-end-484\"\u003e\u003cspan\u003e \u003c\/span\u003eis distinguished by its factory-applied conformal coating, providing superior protection against corrosive G3-level environments.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eDesigned for vertical mounting to maximize cabinet space and enhance thermal convection, this controller manages thousands of I\/O points while maintaining high-speed communication with the human-machine interface (HMI) and other peer controllers. It is the definitive choice for global industries—including LNG terminals, large-scale refineries, and pharmaceutical plants—where a single second of downtime translates to significant financial loss.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"citation-483\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e8C-PCNT02\u003c\/strong\u003e\u003cspan class=\"citation-483 citation-end-483\"\u003e\u003cspan\u003e \u003c\/span\u003earchitecture leverages a modular and robust design focused on system-wide reliability and data integrity.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-482\"\u003e\u003c\/span\u003e\u003cstrong\u003eDeterministic Execution Environment (CEE)\u003c\/strong\u003e\u003cspan class=\"citation-482 citation-end-482\"\u003e: Supports the execution of complex Function Block Diagrams (FBD) and Sequential Function Charts (SFC) at selectable sub-second intervals.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundancy by Design\u003c\/strong\u003e: When paired with a second module and a redundancy cable, the 8C-PCNT02 provides seamless, \"bumpless\" failover, ensuring that control remains uninterrupted during a hardware fault.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Connectivity\u003c\/strong\u003e: Features dual-redundant I\/O Link ports for communication with Series 8 I\/O modules and dual FTE (Fault Tolerant Ethernet) ports for high-security network integration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eG3 Conformal Coating\u003c\/strong\u003e: Specifically treated to withstand harsh chemical atmospheres (H2S, Cl2, SO2), extending the lifespan of the processor in corrosive industrial zones.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-481\"\u003e\u003c\/span\u003e\u003cstrong\u003eVertical Form Factor\u003c\/strong\u003e\u003cspan class=\"citation-481 citation-end-481\"\u003e: Part of the Series 8 \"Slim\" profile, it mounts onto a dedicated C300 IOTA (Input Output Termination Assembly) for simplified wiring and module replacement.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8C-PCNT02\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eExperion PKS Series 8\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProcessor Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eC300 Controller\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEnvironment Protection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eG3 Conformal Coated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMemory\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNon-volatile flash memory for strategy storage\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to +70 Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Input\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC nominal (via IOTA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRedundancy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupported (Hardware \u0026amp; Software)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.85 kg (Net) \/ 3.0 kg (Shipping)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCE, UL, FM Class I Div 2, ATEX Zone 2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary difference between the 8C-PCNT01 and the 8C-PCNT02?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 8C-PCNT02 is the modernized hardware revision, typically featuring optimized memory handling and enhanced processing speed to support larger control strategies and higher-version Experion PKS software releases.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this processor require a battery for program backup?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"citation-480 citation-end-480\"\u003eThe 8C-PCNT02 utilizes high-speed non-volatile RAM and flash memory.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eWhile a battery-backed RAM module was used in older iterations, modern C300 units are designed to retain the control strategy in flash memory during total power loss.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I mix coated and non-coated modules in the same rack?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile technically possible, it is not recommended for environments requiring G3 protection. If the processor is coated (8C-PCNT02), the associated IOTA and I\/O modules should also be coated to ensure the entire control loop remains protected against corrosion.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIOTA Mounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 8C-PCNT02 must be installed on a C300 IOTA (e.g., 8C-TCNTA1). Ensure the grounding lugs on the IOTA are securely bonded to the plant's instrument earth. Poor grounding can lead to FTE communication errors and \"bad quality\" status on I\/O points.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFTE Network Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen connecting the Fault Tolerant Ethernet (FTE) cables, ensure that \"Yellow\" and \"Green\" cables are not swapped. The C300 utilizes specific port logic to determine network paths; crossing these can result in a \"Secondary Network Failure\" alarm in the Experion System Status Display.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSeries 8 controllers rely on natural vertical convection for cooling. Ensure there is at least 150 mm of clearance above and below the controller row. In high-density cabinets, the use of a cabinet fan is recommended to keep the internal ambient temperature below 70 Celsius to prevent processor throttling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52679341932907,"sku":"8C-PCNT02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/8c-pcnt02-mzbnuuokt4d_95e66450-a71c-4412-a9e9-8ba4b8f2b1d1.jpg?v=1765958219"},{"product_id":"honeywell-series-8-8c-paiha1-analog-input-module-with-hart","title":"Honeywell Series 8 8C-PAIHA1 Analog Input Module with HART","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell 8C-PAIHA1 (8CPAIHA1)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density Analog Input module featuring integrated\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHART\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecommunication, specifically designed for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eExperion PKS Series 8\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eI\/O platform. This module is an essential component for modern industrial process control, supporting 16 channels of single-ended analog signals. By combining standard 4-20 mA data acquisition with the Highway Addressable Remote Transducer (HART) protocol, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-PAIHA1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eallows the DCS to access advanced field device diagnostics, secondary variables, and configuration data directly through the I\/O bus. Its \"Series 8\" form factor is engineered for vertical mounting, which optimizes cabinet airflow and provides a compact footprint for large-scale deployments in oil refineries, chemical plants, and power generation facilities.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-PAIHA1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis built for high-reliability mission-critical applications with a focus on data integrity and ease of maintenance.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSingle-Ended Architecture\u003c\/strong\u003e: Optimizes channel density by using a common return path, allowing for 16 high-precision inputs in a single slim module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHART Pass-Through\u003c\/strong\u003e: Each channel supports bidirectional digital communication, enabling seamless integration with Asset Management Systems (AMS) for predictive maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeries 8 Form Factor\u003c\/strong\u003e: Features a unique vertical \"plug-in\" design that interfaces with a dedicated Input Output Termination Assembly (IOTA).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGalvanic Isolation\u003c\/strong\u003e: Provides robust protection between field-side signals and the internal I\/O Link, preventing ground loops and protecting the C300 controller.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSmart Filtering\u003c\/strong\u003e: Integrates advanced digital filtering to reject 50\/60 Hz mains interference, ensuring stable readings even in electrically noisy industrial environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8C-PAIHA1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eExperion PKS Series 8\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAnalog Input with HART (Single-Ended)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 to 20 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16-bit A\/D Converter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHART Version\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHART 5, 6, and 7 supported\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to +70 Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCoating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eG3 Conformal Coating (Standard)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.45 kg (Net) \/ 3.0 kg (Shipping)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 8C-PAIHA1 support power for 2-wire transmitters?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. When paired with the correct IOTA (Input Output Termination Assembly), the module provides the necessary loop power to energize standard 2-wire field transmitters.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of the G3 Conformal Coating on this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eHoneywell Series 8 modules typically come with G3 coating as standard, protecting the internal circuitry against corrosion caused by harsh chemical atmospheres (such as\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$H_2S$\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$SO_2$\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003efound in refineries).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I replace this module while the system is running?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The 8C-PAIHA1 supports \"Hot-Swapping\" (Removal and Insertion Under Power), allowing for maintenance without interrupting the control of other modules on the same I\/O Link.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIOTA Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 8C-PAIHA1 must be installed on a compatible Series 8 IOTA (e.g., 8C-TAIXA1 or 8C-TAIXB1). Ensure the IOTA is properly grounded to the cabinet's instrument earth bar to maintain the 16-bit signal resolution and HART communication stability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSingle-Ended Wiring Caution:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBecause this is a single-ended module, all 16 channels share a common return. It is critical to ensure that field devices do not have conflicting ground potentials, as this can introduce measurement errors or \"ghost\" signals across multiple channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHeat Dissipation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSeries 8 modules are designed for vertical orientation to facilitate natural convection. Do not obstruct the ventilation slots on the IOTA or the module housing. Maintain the manufacturer-recommended spacing between I\/O rows to prevent thermal derating in ambient temperatures exceeding 60 Celsius.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52705765032299,"sku":"8C-PAIHA1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/8c-paiha1-kqgsmq0gt0n_3f3c81ff-b903-415a-aeb4-b32214140a87.jpg?v=1766659460"},{"product_id":"honeywell-51202971-101-series-8-i-o-link-1-cable-assembly","title":"Honeywell 51202971-101 Series 8 I\/O Link 1 Cable Assembly","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell 51202971-101\u003c\/strong\u003e is a Series 8 I\/O Link 1 (IOL1) Drop Cable Assembly designed for interconnecting Series 8 Input\/Output Termination Assemblies (IOTAs) within Experion LX control system cabinets. Operating as Cable B in a redundant I\/O Link configuration, this \u003cstrong\u003e51202971-101\u003c\/strong\u003e multi-drop cable features a gray jacket with green connector labels marked for IOL1B identification. It provides vertical signal and communications distribution across mounting plate columns at a 750 Kbps transfer rate, connecting C300 controllers and Series 8 I\/O modules to system header boards and adjacent IOTAs.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundant Link B Identification:\u003c\/strong\u003e Features a green connector label and IOL1B symbol marking for accurate identification in I\/O Link 1 redundant pairs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-Drop Vertical Routing:\u003c\/strong\u003e Engineered with 6 drops at a 6-inch (152 mm) pitch to route vertically within cabinet mounting plates.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Speed Communication:\u003c\/strong\u003e Supports the standard 750 Kbps Series 8 I\/O Link serial communication network.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Integration:\u003c\/strong\u003e Connects C300 controllers, header boards, and various Series 8 IOTAs without exiting the physical enclosure complex.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHoneywell Experion LX Series 8 Control System Cabinets\u003c\/li\u003e\n\u003cli\u003eC300 Controller to Series 8 I\/O Link 1 (IOL1) interconnection\u003c\/li\u003e\n\u003cli\u003eVertical IOTA signal distribution across cabinet mounting plates\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eCable Type\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eLabel Color\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e51202971-100\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGray Drop Cable, 6 drops, 6-inch (152 mm) pitch, yellow label\u003c\/td\u003e\n\u003ctd\u003eCable A\u003c\/td\u003e\n\u003ctd\u003eYellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e51202971-101\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGray Drop Cable, 6 drops, 6-inch (152 mm) pitch, green label\u003c\/td\u003e\n\u003ctd\u003eCable B\u003c\/td\u003e\n\u003ctd\u003eGreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e51202971-102\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCable pair consisting of one 51202971-100 and one 51202971-101\u003c\/td\u003e\n\u003ctd\u003eCable Pair (A \u0026amp; B)\u003c\/td\u003e\n\u003ctd\u003eYellow \/ Green\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e51202971-101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Line\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries 8 I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries 8 I\/O Link 1 (IOL1) Link B Drop Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Drops\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 drops\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDrop Pitch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 inches (152 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Color\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGray\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Label Color\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIOTA Symbol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIOL1B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBaud Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e750 Kbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Boundary:\u003c\/strong\u003e Keep I\/O Link cables entirely within the physical confines of the cabinet or cabinet complex; cables must not exit the front, rear, sides, top, or bottom.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel Placement:\u003c\/strong\u003e Route cable vertically along designated wireways in cabinet mounting plates to connect Series 8 IOTAs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Separation:\u003c\/strong\u003e Ensure IOTAs associated with field wiring over 30 V are physically separated from IOTAs associated with field wiring under 30 V to minimize electrical interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePair Matching:\u003c\/strong\u003e Install alongside the corresponding Cable A assembly (51202971-100) to form a complete redundant I\/O Link 1 connection.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53667849077099,"sku":"51202971-101","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/51202971-101_1200x1200_84b5978d-e654-4ab6-8d8e-6aff1fd891b7.jpg?v=1785937706"},{"product_id":"honeywell-900r12r-0300-experion-lx-12-i-o-slot-rack-with-redundant-power-support","title":"Honeywell 900R12R-0300 Experion LX 12 I\/O Slot Rack with Redundant Power Support","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell 900R12R-0300\u003c\/strong\u003e is an extended-temperature 12 I\/O slot rack engineered for the ControlEdge 900 platform, providing structural mounting and backplane connections with redundant power supply support. Designed for housing ControlEdge 900 modules, the rack provides backplane communication and power distribution across up to 12 I\/O slots while operating across an extended temperature range of -40 to 70 degC.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAccommodates up to 12 I\/O slots in a single rack assembly.\u003c\/li\u003e\n\u003cli\u003eDesigned with redundant power supply support for high-availability configurations.\u003c\/li\u003e\n\u003cli\u003eRated for extended ambient operating temperatures ranging from -40 to 70 degC.\u003c\/li\u003e\n\u003cli\u003eIntegrated into the modular rack-based ControlEdge 900 hardware platform.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDistributed Control Systems (DCS) and Unit Operations Controller (UOC) hardware installations.\u003c\/li\u003e\n\u003cli\u003eIndustrial automation processes requiring expanded local or remote I\/O rack capacity.\u003c\/li\u003e\n\u003cli\u003eHigh-availability process control environments requiring redundant power topologies.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e900R12R-0300\u003c\/td\u003e\n\u003ctd\u003e12 I\/O slot Rack with redundant power support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e900R12R-0300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eI\/O Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 I\/O slots\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRedundant power support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 to 70 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e137 mm H x 683.3 mm W x 151.7 mm D (5.4 in H x 26.9 in W x 6.0 in D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5252 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure adequate spacing around the rack assembly for proper cooling and airflow.\u003c\/li\u003e\n\u003cli\u003eSecurely mount the rack inside the control enclosure prior to module insertion.\u003c\/li\u003e\n\u003cli\u003eVerify proper backplane alignment when installing power supplies and I\/O modules.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53706926489963,"sku":"900R12R-0300","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/900R12R-0300_001_1200x1200_1e56fc1b-7fa1-485d-bc5f-dcf367d4c16f.jpg?v=1786459668"},{"product_id":"honeywell-8c-taixa1-51307125-175-series-8-non-redundant-analog-input-iota-assembly-coated","title":"Honeywell 8C-TAIXA1 51307125-175 Series 8 Non-Redundant Analog Input IOTA Assembly Coated","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell 8C-TAIXA1\u003c\/strong\u003e (Part Number \u003cstrong\u003e51307125-175\u003c\/strong\u003e) is a non-redundant \u003cstrong\u003eAnalog Input I\/O Termination Assembly (IOTA)\u003c\/strong\u003e within the Experion PKS Series 8 C300 control system platform. Designed for compact panel layouts, this 6-inch termination assembly provides physical field wiring connection terminals and mounting carrier infrastructure for 16-channel analog input modules, specifically supporting HART-enabled analog input modules such as the \u003cstrong\u003e8C-PAIHA1\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell 8C-TAIXA1 51307125-175\u003c\/strong\u003e interfaces 4-20 mA current loops from 2-wire loop-powered or 4-wire self-powered transmitters directly into the C300 controller architecture. It features factory conformal coating to shield physical traces, terminal blocks, and passive components from industrial airborne contaminants, corrosive gases, and humidity.\u003c\/p\u003e\n\u003cp\u003eServing as the physical mounting foundation, the non-redundant IOTA assembly allows field wiring to remain permanently attached to screw terminals while facilitating seamless I\/O Module Removal and Insertion Under Power (RIUP). This architecture minimizes downtime during maintenance and streamlines cabinet field wiring.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Form Factor\u003c\/strong\u003e: Measures 6 inches in width, saving space on panel DIN rails while providing termination points for up to 16 analog input channels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFactory Conformal Coating\u003c\/strong\u003e: Conformal coating protects trace layouts, solder joints, and terminal interconnections against aggressive chemical environments and humidity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle-Module IOTA Carrier\u003c\/strong\u003e: Built for non-redundant control configurations, accommodating a single 16-channel Series 8 Analog Input module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDirect Field Transmitter Interface\u003c\/strong\u003e: Connects 4-20 mA DC signals from 2-wire loop-powered and self-powered process instrumentation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOnline Maintenance Support\u003c\/strong\u003e: Enables Module Removal and Insertion Under Power (RIUP) without disconnecting field wiring or interrupting power to adjacent assemblies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegral Bus Interconnects\u003c\/strong\u003e: Provides internal routing for 24 VDC system distribution and high-speed communication buses to the C300 execution environment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eExperion PKS Series 8 Cabinet Integration\u003c\/strong\u003e: Serves as the physical termination base for non-redundant 16-channel analog input modules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcess Instrumentation Wiring\u003c\/strong\u003e: Terminates field signals from pressure transmitters, temperature transmitters, flowmeters, and level sensors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous \u0026amp; Corrosive Plant Enclosures\u003c\/strong\u003e: Deployed in process environments requiring conformal coated termination hardware to withstand harsh atmospheric conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous Control Strategies\u003c\/strong\u003e: Relays high-density analog loop measurements directly to C300 controllers for real-time monitoring and process logic.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003e8C-TAIXA1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e51307125-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eNon-Redundant Analog Input I\/O Termination Assembly (IOTA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Architecture\u003c\/td\u003e\n\u003ctd\u003eExperion PKS Series 8 C300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy\u003c\/td\u003e\n\u003ctd\u003eNon-Redundant (Single Module)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurface Protection\u003c\/td\u003e\n\u003ctd\u003eFactory Conformal Coated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported I\/O Module\u003c\/td\u003e\n\u003ctd\u003e8C-PAIHA1 (Analog Input with HART, 16-Channel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eElectrical \u0026amp; Signal Properties\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Capacity\u003c\/td\u003e\n\u003ctd\u003e16 Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Type\u003c\/td\u003e\n\u003ctd\u003eCurrent (4-20 mA DC through 250 Ohm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Device Support\u003c\/td\u003e\n\u003ctd\u003e2-wire (loop-powered) or self-powered transmitters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage Rating\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Input Voltage Rating\u003c\/td\u003e\n\u003ctd\u003e+\/- 30 Volts (any input referenced to common, no damage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003ePhysical \u0026amp; Mechanical\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Base Width\u003c\/td\u003e\n\u003ctd\u003e6 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHot Swappability\u003c\/td\u003e\n\u003ctd\u003eSupports Module Removal and Insertion Under Power (RIUP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Termination Type\u003c\/td\u003e\n\u003ctd\u003eScrew-type terminal block connections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Terminal Blocks\u003c\/td\u003e\n\u003ctd\u003eTerminal strip connections for 16-channel 4-20 mA transmitter loops\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Module Socket\u003c\/td\u003e\n\u003ctd\u003eMulti-pin backplane connector for mounting the 8C-PAIHA1 module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Power Bus\u003c\/td\u003e\n\u003ctd\u003eInternal 24 VDC bus routing for module power distribution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eEnsure panel DC power supplies are isolated before mounting or wiring the IOTA assembly.\u003c\/li\u003e\n\u003cli\u003eSecure the 8C-TAIXA1 6-inch termination assembly onto standard panel enclosure DIN rail structures using appropriate end stops.\u003c\/li\u003e\n\u003cli\u003eWire field transmitters to designated channel terminals according to 2-wire or self-powered device wiring diagrams.\u003c\/li\u003e\n\u003cli\u003eVerify field wiring polarity and ensure proper grounding\/shielding practices are implemented across signal lines.\u003c\/li\u003e\n\u003cli\u003eAlign the corresponding Series 8 I\/O module (e.g., 8C-PAIHA1) with the socket headers on the 8C-TAIXA1 assembly.\u003c\/li\u003e\n\u003cli\u003ePress the module firmly into place until retaining mechanical latches click into place.\u003c\/li\u003e\n\u003cli\u003eApply 24 VDC system power and verify power and channel status indicators on the mounted module.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eConfiguration \/ Commissioning \/ Replacement Guidelines\u003c\/h3\u003e\n\u003ch4\u003eConfiguration Guidelines\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eAssign physical channel numbers in Honeywell Control Builder to match the field terminal assignments on the 8C-TAIXA1 assembly.\u003c\/li\u003e\n\u003cli\u003eSelect correct input channel modes (4-20 mA current loop settings) within the Experion software environment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCommissioning Recommendations\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003ePerform loop checks by verifying current signals at the 8C-TAIXA1 field terminal screws with a calibrated process calibrator prior to system sign-off.\u003c\/li\u003e\n\u003cli\u003eEnsure all field signal shield lines are ground-terminated at the dedicated cabinet ground bar and isolated from the IOTA base.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eReplacement Recommendations\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eModule Removal and Insertion Under Power (RIUP) allows replacing the mounted I\/O module without removing field wires from the 8C-TAIXA1 assembly.\u003c\/li\u003e\n\u003cli\u003eIf replacing the 8C-TAIXA1 termination base itself, turn off 24 VDC field power, disconnect field signal terminals, unlatch the mounted I\/O module, and unmount the base from the DIN rail.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53730639577451,"sku":"8C-TAIXA1","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/8C-TAIXA1-51307125-175_001_1200x1200_3665a9cc-6b1d-47b5-9840-f9512e6fd4ae.jpg?v=1786885667"}],"url":"https:\/\/www.plcprotech.com\/it\/collections\/honeywell-experion-lx-series-8.oembed","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}