{"title":"Honeywell","description":"\u003cp\u003eHoneywell is a global leader in industrial automation and control, providing integrated solutions for energy, manufacturing, and process safety. The brand architecture encompasses everything from sophisticated \u003ca href=\"https:\/\/www.plcprotech.com\/collections\/honeywell-experion-pks-c300-series-c\"\u003eExperion PKS C300\u003c\/a\u003e distributed control systems to precise SmartLine field instruments. Key technical characteristics include high-availability hardware, robust cybersecurity protocols, and universal I\/O capabilities. Functionally, Honeywell components facilitate real-time monitoring, optimized combustion via burner controls, and comprehensive \u003ca href=\"https:\/\/www.plcprotech.com\/collections\/honeywell-gas-flame-detection\"\u003egas and flame detection\u003c\/a\u003e. By combining advanced software with ruggedized field devices, Honeywell ensures operational continuity, safety, and efficiency across complex industrial landscapes including oil and gas, chemical processing, and power generation sectors.\u003c\/p\u003e","products":[{"product_id":"honeywell-fc-scnt02-51460114-17-safety-manager-sc-controller-module","title":"Honeywell FC-SCNT02 51460114-17 Safety Manager SC Controller Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell FC-SCNT02\u003c\/strong\u003e is a controller module engineered for the Safety Manager SC system. It serves as a functional replacement for the FC-SCNT01 module within safety system architectures and can be swapped online without interrupting process operations. In redundant Safety Manager SC (SMSC) controller configurations, the module functions side-by-side with an existing FC-SCNT01 module.\u003c\/p\u003e\n\u003cp\u003eThe module supports DNP3 protocol outstation functionality starting with Safety Manager SC release R212, allowing the Safety Manager SC to operate as a DNP3 Outstation while communicating with a DNP3 Master such as an Experion Server or ControlEdge RTU. It also functions as a direct spare part for the FC-SCNT01 module, maintaining full operational feature parity with the legacy module.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDirect functional replacement and spare part for the FC-SCNT01 controller module\u003c\/li\u003e\n\u003cli\u003eOnline replacement capability without disrupting running operations\u003c\/li\u003e\n\u003cli\u003eRedundant operations support, functioning alongside an FC-SCNT01 module in SMSC controllers\u003c\/li\u003e\n\u003cli\u003eIntegrated DNP3 protocol outstation support (requires release R212)\u003c\/li\u003e\n\u003cli\u003eCompatible with Safety Manager SC software release R200.2 and higher\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSafety Instrumented Systems (SIS) and Emergency Shutdown (ESD) applications\u003c\/li\u003e\n\u003cli\u003eSafety Manager SC redundant controller configurations\u003c\/li\u003e\n\u003cli\u003eIndustrial SCADA telecontrol communication networks utilizing DNP3 protocol outstation integration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFC-SCNT02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Mumber\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e51460114-17\u003c\/td\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSafety Manager SC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupported Software Release\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSafety Manager SC R200.2 and higher\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDNP3 Protocol Support Release\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSafety Manager SC R212 and higher\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Replacement Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOnline replacement \/ Hot Swap capable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRedundancy Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDual redundant controller configuration with FC-SCNT01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOnline Replacement:\u003c\/strong\u003e The module can be installed or replaced online in a running Safety Manager SC system without requiring a shutdown.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundant Pair Coexistence:\u003c\/strong\u003e In redundant controller setups, an FC-SCNT02 module can be installed alongside an existing FC-SCNT01 module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSoftware Prerequisites:\u003c\/strong\u003e Verify that the Safety Manager SC system software is at release R200.2 or higher before module installation, and release R212 or higher if utilizing DNP3 outstation features.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667735474539,"sku":"FC-SCNT02 51460114-176","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/FC-SCNT02_1.jpg?v=1785591830"},{"product_id":"honeywell-51309152-175-output-module-board","title":"Honeywell 51309152-175 Output Module Board","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell 51309152-175 is a specialized output module board engineered for integration within industrial automation and distributed control system (DCS) architectures. Designed to interface seamlessly with legacy and expanded control frameworks, this hardware component facilitates reliable signal processing and command execution across complex operational nodes. It plays a critical role in bridging controller logic with field-level actuation devices, ensuring precise output management in demanding industrial environments.\u003c\/p\u003e\n\u003cp\u003eAs part of the established MU-T series ecosystem, this output module board supports streamlined rack mounting and robust electrical connectivity. Its hardware layout is constructed to withstand standard industrial operating conditions while maintaining deterministic communication and low latency within the broader control network. Technicians and system integrators utilize this exact part number for hardware expansion, scheduled maintenance, or direct component replacement in continuous process control applications.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eEngineered specifically for Honeywell distributed control system (DCS) deployments\u003c\/li\u003e\n  \u003cli\u003eCompatible with MU-T series rack assemblies and standard system backplanes\u003c\/li\u003e\n  \u003cli\u003eFacilitates reliable command signal transmission to downstream process actuators\u003c\/li\u003e\n  \u003cli\u003eRigid industrial construction designed for standard control room or cabinet installations\u003c\/li\u003e\n  \u003cli\u003eDirect replacement part matching original factory form, fit, and functional parameters\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eContinuous process manufacturing and chemical plants\u003c\/li\u003e\n  \u003cli\u003eOil and gas refining and upstream monitoring facilities\u003c\/li\u003e\n  \u003cli\u003ePower generation and turbine control systems\u003c\/li\u003e\n  \u003cli\u003eWater and wastewater treatment infrastructure\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eHoneywell\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eExact Model\u003c\/td\u003e\n      \u003ctd\u003e51309152-175\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003eOutput Module Board\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSeries\u003c\/td\u003e\n      \u003ctd\u003eMU-T Series\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSystem Environment\u003c\/td\u003e\n      \u003ctd\u003eDistributed Control System (DCS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCountry of Origin\u003c\/td\u003e\n      \u003ctd\u003eUSA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNet Weight\u003c\/td\u003e\n      \u003ctd\u003e0.58 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDimensions\u003c\/td\u003e\n      \u003ctd\u003e2.9 cm x 31.9 cm x 27.9 cm\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eVerify that the replacement part number 51309152-175 matches the exact requirements of the target control slot.\u003c\/li\u003e\n  \u003cli\u003eDe-energize the associated system rack and follow standard lockout\/tagout (LOTO) safety procedures before handling hardware.\u003c\/li\u003e\n  \u003cli\u003eInspect the module and backplane connectors for any signs of physical damage or debris.\u003c\/li\u003e\n  \u003cli\u003eCarefully align the board with the designated guide rails and insert it firmly into the system backplane slot.\u003c\/li\u003e\n  \u003cli\u003eSecure any retention fasteners to ensure stable mechanical mounting and proper electrical grounding.\u003c\/li\u003e\n  \u003cli\u003eRestore system power and verify module status via the control system management interface.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667736621419,"sku":"51309152-175","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-51309152-175-output-module-board-ndhz5ijhnlk_ff8eed3f-8ee0-468f-9483-9241cf65c6bf.jpg?v=1765501317"},{"product_id":"honeywell-mc-tdia72-51303930-150-digital-input-termination-board","title":"Honeywell MC-TDIA72 51303930-150 Digital Input Termination Board","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell MC-TDIA72 (Model 51303930-150) is a high-density digital input termination board engineered for integration within Honeywell Experion PKS and TDC 3000 distributed control systems. As a key component of the MU-T Series termination assembly infrastructure, this termination board provides reliable signal interfacing between field-mounted digital input devices and system input modules. It facilitates clean signal transition, proper field wiring consolidation, and system protection in demanding continuous process manufacturing environments.\u003c\/p\u003e\n\u003cp\u003eDesigned to handle standard industrial discrete field signals, the MC-TDIA72 termination board routes inputs securely to control hardware while maintaining electrical separation and signal integrity. Its architecture minimizes point-to-point wiring errors during installation and simplifies ongoing maintenance routines in large-scale industrial automation plants.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n    \u003cli\u003eEngineered specifically for Honeywell Experion PKS and TDC control system architectures\u003c\/li\u003e\n    \u003cli\u003ePart of the robust MU-T Series modular termination assembly family\u003c\/li\u003e\n    \u003cli\u003eFacilitates organized field wiring termination for high-density digital input signals\u003c\/li\u003e\n    \u003cli\u003eDesigned for secure panel mounting within industrial control cabinets\u003c\/li\u003e\n    \u003cli\u003eMinimizes signal degradation with optimized circuit trace resistance\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n    \u003cli\u003eOil and gas upstream and downstream processing facilities\u003c\/li\u003e\n    \u003cli\u003eChemical and petrochemical manufacturing plants\u003c\/li\u003e\n    \u003cli\u003ePower generation and utility distribution control systems\u003c\/li\u003e\n    \u003cli\u003ePulp, paper, and heavy industrial automation processes\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n    \u003cthead\u003e\n        \u003ctr\u003e\n            \u003cth\u003eParameter\u003c\/th\u003e\n            \u003cth\u003eSpecification\u003c\/th\u003e\n        \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eManufacturer\u003c\/td\u003e\n            \u003ctd\u003eHoneywell\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eProduct Model\u003c\/td\u003e\n            \u003ctd\u003eMC-TDIA72\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003ePart \/ Ordering Number\u003c\/td\u003e\n            \u003ctd\u003e51303930-150\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eProduct Type\u003c\/td\u003e\n            \u003ctd\u003eDigital Input Termination Board\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eSeries\u003c\/td\u003e\n            \u003ctd\u003eMU-T Series\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n            \u003ctd\u003eHoneywell Experion PKS \/ TDC 3000 DCS\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eMounting Type\u003c\/td\u003e\n            \u003ctd\u003ePanel Mount\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eCountry of Origin\u003c\/td\u003e\n            \u003ctd\u003eUSA\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eNet Weight\u003c\/td\u003e\n            \u003ctd\u003e0.82 kg\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eDimensions\u003c\/td\u003e\n            \u003ctd\u003e46.1 cm x 12.0 cm x 5.5 cm\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n    \u003cli\u003eVerify the exact model number (MC-TDIA72 51303930-150) against system engineering drawings before uncrating.\u003c\/li\u003e\n    \u003cli\u003eEnsure all associated cabinet power supplies and field signal loops are completely de-energized and locked out.\u003c\/li\u003e\n    \u003cli\u003eInspect the termination board visually for any transit-related damage or bent connection pins.\u003c\/li\u003e\n    \u003cli\u003eSecurely mount the termination board to the designated panel subplate using appropriate mounting hardware.\u003c\/li\u003e\n    \u003cli\u003eConnect field wiring to the designated terminal blocks according to the system loop diagrams.\u003c\/li\u003e\n    \u003cli\u003eConnect the pre-engineered system cable between the termination board and the corresponding I\/O module.\u003c\/li\u003e\n    \u003cli\u003ePerform a complete continuity and loop check before restoring system power and commissioning the inputs.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667736850795,"sku":"MC-TDIA72 51303930-150","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-mc-tdia72-51303930-150-digital-input-termination-board-bhcm5px5fbi_44d1e2b5-6b93-4038-8c9e-47d4612757d4.jpg?v=1765501326"},{"product_id":"honeywell-cc-paix01-51405038-275-experion-pks-series-c-high-level-analog-input-module","title":"Honeywell CC-PAIX01 51405038-275 Experion PKS Series C High-Level Analog Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell CC-PAIX01\u003c\/strong\u003e (Part Number \u003cstrong\u003e51405038-275\u003c\/strong\u003e) is a 16-channel High-Level Analog Input (HLAI) module designed for the Honeywell Experion PKS Series C I\/O family. Engineered to interface directly with a Honeywell C300 controller via the dedicated I\/O Link network, the module provides high-density signal conditioning and A\/D conversion for standard industrial analog current and voltage field transmitters.\u003c\/p\u003e\n\u003cp\u003eOperating under the control of the C300 controller using the AI-HL IOM function block in Control Builder, the \u003cstrong\u003eCC-PAIX01\u003c\/strong\u003e processes incoming field signals independently of the main controller execution cycle. The module supports differential input configurations on channels 13 through 16 alongside single-ended high-level inputs, offering signal flexibility and noise suppression for critical process loops.\u003c\/p\u003e\n\u003cp\u003eDesigned for demanding process control environments, the \u003cstrong\u003e51405038-275\u003c\/strong\u003e module mounts directly onto Series C Input Output Termination Assemblies (IOTAs). It supports hardware redundancy when installed on compatible redundant IOTA boards, enabling automatic switchover and continuous process monitoring without interruption. Note that the \u003cstrong\u003eCC-PAIX01\u003c\/strong\u003e model has been officially succeeded by the \u003ca href=\"\/it\/products\/honeywell-cc-paih02-51405038-375-c300-high-level-analog-input-with-hart\"\u003e\u003cstrong\u003eCC-PAIX02\u003c\/strong\u003e\u003c\/a\u003e model, which expands differential input support across all 16 channels.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e16 High-Level Channels:\u003c\/strong\u003e Provides 16 input channels designed to accept high-level analog signals from 2-wire and self-powered field transmitters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelectable Differential Inputs:\u003c\/strong\u003e Supports differential input signal connections on channels 13 through 16 for enhanced common-mode noise rejection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eC300 \u0026amp; I\/O Link Integration:\u003c\/strong\u003e Communicates natively with C300 controllers over the I\/O Link network via the AI-HL function block in Control Builder.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy Support:\u003c\/strong\u003e Fully supports redundant hardware configurations on designated Series C IOTAs to maintain process availability during single-module maintenance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHot-Swappable Design:\u003c\/strong\u003e Mounts onto Series C IOTAs with an angled insertion design, enabling online removal and replacement under power without disturbing field wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOnboard Diagnostics:\u003c\/strong\u003e Integrates self-diagnostic capabilities with CTools software monitoring to report hardware health and firmware status in real time.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous Process Monitoring:\u003c\/strong\u003e Interfacing standard high-level current and voltage field transmitters with Experion PKS control systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDifferential Signal Acquisition:\u003c\/strong\u003e Connecting noisy or non-isolated analog loops on channels 13 through 16 to eliminate ground loop interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Loop Feedback:\u003c\/strong\u003e Supplying high-density analog process variables (PV) for flow, pressure, temperature, and level loops managed by C300 controllers.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExact Model\u003c\/td\u003e\n\u003ctd\u003eCC-PAIX01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e51405038-275\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eExperion PKS Series C I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eHigh-Level Analog Input Module (Non-HART)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eController Compatibility\u003c\/td\u003e\n\u003ctd\u003eHoneywell C300 Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIOM Block Name\u003c\/td\u003e\n\u003ctd\u003eAI-HL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuccessor Model\u003c\/td\u003e\n\u003ctd\u003eCC-PAIX02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eInput \/ Output\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Type\u003c\/td\u003e\n\u003ctd\u003eHigh-Level Current \/ Voltage (Non-HART)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDifferential Input Channels\u003c\/td\u003e\n\u003ctd\u003eChannels 13 through 16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Interface\u003c\/td\u003e\n\u003ctd\u003eSeries C I\/O Link\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration Method\u003c\/td\u003e\n\u003ctd\u003eHoneywell Control Builder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eOperational Capabilities\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy\u003c\/td\u003e\n\u003ctd\u003eSupported on redundant IOTA boards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInitialization Time (Module Power Loss)\u003c\/td\u003e\n\u003ctd\u003e10 seconds (+\/- 25%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Switchover Performance\u003c\/td\u003e\n\u003ctd\u003eEquivalent to PM I\/O switchover time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRear Board Edge Connector\u003c\/td\u003e\n\u003ctd\u003eConnects directly to Series C Input Output Termination Assembly (IOTA) for power, backplane bus, and field signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries C I\/O Link\u003c\/td\u003e\n\u003ctd\u003eSerial communication link managed by the C300 controller for data transfer and module programming\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003ePre-Installation Inspection:\u003c\/strong\u003e Confirm the exact part number \u003cstrong\u003e51405038-275\u003c\/strong\u003e on the module side label and inspect the physical connector pins for damage prior to installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIOTA Mounting:\u003c\/strong\u003e Ensure the target Series C IOTA carrier is securely fastened inside the cabinet and properly bonded to protective earth ground.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Insertion:\u003c\/strong\u003e Align the module housing with the guide tracks of the target IOTA slot. Slide the module in at the standard 18-degree tilt angle until the locking latches click firmly into place.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Wiring Verification:\u003c\/strong\u003e Route high-level analog current or voltage input signal wires to the corresponding terminals on the IOTA. Ensure differential signal sources are correctly assigned to channels 13 through 16.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Link Verification:\u003c\/strong\u003e Verify that the I\/O Link cable connectors on the IOTA carrier are tight and assigned the correct physical address jumper matching the software setup.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eConfiguration \/ Commissioning \/ Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Builder Setup:\u003c\/strong\u003e Assign an AI-HL module block under the corresponding IOLINK master block in Honeywell Control Builder, matching the assigned hardware address on the IOTA.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundant Module Replacement:\u003c\/strong\u003e When replacing an older revision \u003cstrong\u003eCC-PAIX01\u003c\/strong\u003e module in a redundant pair, verify hardware revision levels. For systems running Experion PKS R310 or later, ensure the controller patch level is updated before pairing older (rev \u0026lt;=K) and newer (rev \u0026gt;=M) hardware revisions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOnline Switchover Check:\u003c\/strong\u003e Upon inserting a replacement module into an energized IOTA slot, monitor CTools to verify that firmware synchronization completes and the module status transitions to green\/active.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667736981867,"sku":"CC-PAIX01 51405038-275","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-cc-paix01-51405038-275-analog-input-module-hknbcxbtnph_4f3b11b1-8363-4f10-bee1-164b1ceb123a.jpg?v=1765501331"},{"product_id":"honeywell-sc-ucnn11-51307573-176-controller-module","title":"Honeywell SC-UCNN11 51307573-176 Controller Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell SC-UCNN11 (model 51307573-176) is a high-performance controller module designed for deployment within Honeywell Experion PKS distributed control systems. This hardware component serves as a central processing node within industrial automation architectures, executing deterministic control strategies and managing complex input and output operations for continuous and discrete process applications.\u003c\/p\u003e\n\u003cp\u003eEngineered for high-availability environments, the module executes control logic, interfaces with Series C I\/O modules, and communicates with supervisory networks. Its architecture supports reliable data exchange and synchronized execution loops required in demanding process industries such as chemical manufacturing, oil and gas production, and power generation.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDesigned for integration within Honeywell Experion PKS control system architectures\u003c\/li\u003e\n  \u003cli\u003eExecutes high-speed deterministic control logic for complex automation strategies\u003c\/li\u003e\n  \u003cli\u003eSupports redundant configuration options to maximize system availability in critical processes\u003c\/li\u003e\n  \u003cli\u003eFeatures onboard diagnostic capabilities for real-time health monitoring and fault detection\u003c\/li\u003e\n  \u003cli\u003eConnects directly to standard plant networks for supervisory control and data acquisition\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDistributed process control in chemical and petrochemical plants\u003c\/li\u003e\n  \u003cli\u003eBatch processing and sequencing in pharmaceutical manufacturing\u003c\/li\u003e\n  \u003cli\u003eSupervisory control and data acquisition in power generation facilities\u003c\/li\u003e\n  \u003cli\u003eOil and gas upstream and downstream automation infrastructure\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eHoneywell\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Series\u003c\/td\u003e\n      \u003ctd\u003eExperion PKS\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModel \/ Ordering Number\u003c\/td\u003e\n      \u003ctd\u003eSC-UCNN11\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePart Number\u003c\/td\u003e\n      \u003ctd\u003e51307573-176\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003eController Module\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n      \u003ctd\u003eExperion C300 \/ Series C Architecture\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCommunication Ports\u003c\/td\u003e\n      \u003ctd\u003eEthernet \/ ControlNet (dependent on platform configuration)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMounting Type\u003c\/td\u003e\n      \u003ctd\u003eSeries C Chassis \/ I\/O Carrier\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCountry of Origin\u003c\/td\u003e\n      \u003ctd\u003eUSA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNet Weight\u003c\/td\u003e\n      \u003ctd\u003e0.26 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDimensions\u003c\/td\u003e\n      \u003ctd\u003e5.6 cm x 12.6 cm x 13.0 cm\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003ctd\u003eVerify the part number and model integrity against system design documentation before installation.\u003c\/td\u003e\n  \u003ctd\u003eEnsure all power to the target Series C slot and associated chassis is de-energized to prevent equipment damage.\u003c\/td\u003e\n  \u003ctd\u003eInspect the module connectors and backplane pins for any debris, contamination, or bending.\u003c\/td\u003e\n  \u003ctd\u003eAlign the module with the designated carrier slot and gently slide it into position until fully seated.\u003c\/td\u003e\n  \u003ctd\u003eSecure any locking mechanisms or retaining screws per standard Series C hardware practices.\u003c\/td\u003e\n  \u003ctd\u003eApply power, verify status LED indicators, and configure or download the control strategy via Experion Engineering tools.\u003c\/td\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667737047403,"sku":"SC-UCNN11 51307573-176","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-sc-ucnn11-51307573-176-controller-module-qxnzh5uvxaf_110cdb8f-c3c4-4b5c-84f0-926c71f813e6.jpg?v=1765501334"},{"product_id":"honeywell-tp-opadp1-200-51196990-500-plc-cable","title":"Honeywell TP-OPADP1-200 Operator Station Adapter 51196990-500","description":"\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTP-OPADP1-200 (51196990-500)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a specialized interface adapter designed for the Honeywell Experion® PKS and TDC 3000 Global User Station (GUS) architectures. This Operator Station Adapter (OSA) facilitates the connection between the high-performance process control network and operator interface hardware. It is engineered to manage the translation of proprietary control bus signals to standard video and peripheral data, ensuring seamless communication between the controller backend and the Human-Machine Interface (HMI) consoles used in centralized control rooms.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTP-OPADP1-200\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e51196990-500\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Category\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOperator Station Hardware \/ Interface Adapter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eExperion PKS, TDC 3000, Global User Station (GUS)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInterface Ports\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh-speed proprietary control bus and peripheral connectivity\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRevision Level\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-200 Series (Modernized hardware standard)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 °C to 50 °C (32 °F to 122 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 °C to +85 °C (-40 °F to +185 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard Operator Console Chassis \/ Rack Mount\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5% to 95% RH (Non-condensing)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eOperational Capabilities\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTP-OPADP1-200\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a vital bridge in legacy and hybrid Honeywell systems. Its primary function is to maintain low-latency data throughput for real-time alarm management, process graphic updates, and operator command execution. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e51196990-500\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ehardware revision includes updated internal circuitry designed to improve heat dissipation and electronic stability compared to earlier -100 series adapters. This ensures the high uptime required for critical monitoring in sectors like refining, petrochemicals, and large-scale power generation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQs\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs the TP-OPADP1-200 interchangeable with the TP-OPADP1-100?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTP-OPADP1-200\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis the functional successor to the -100 version. While it is generally backward compatible, it offers improved reliability and is the recommended replacement for aging operator stations to ensure long-term stability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this adapter require specific software drivers?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the adapter requires the appropriate Experion or TDC 3000 software environment and hardware-level drivers to be recognized by the operating system of the GUS or workstation.\u003c\/p\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667737866603,"sku":"TP-OPADP1-200 51196990-500","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-tp-opadp1-200-51196990-500-plc-cable-14mfroao5sr_5b7634ff-892a-48e4-9b10-b701ba5c1962.jpg?v=1765501355"},{"product_id":"honeywell-mc-tamr04-51305907-175-low-level-input-multiplexer","title":"Honeywell MC-TAMR04 51305907-175 Low Level Input Multiplexer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell MC-TAMR04 (Model 51305907-175) is a specialized low-level input multiplexer module engineered for integration within legacy Honeywell Distributed Control Systems (DCS), specifically supporting the TDC 3000 and related process automation platforms. This hardware component is designed to manage and condition low-level analog signals originating from sensitive industrial field instrumentation, such as thermocouples and RTDs, before passing them on to the greater control system architecture.\u003c\/p\u003e\n\u003cp\u003eAs an essential interface in heavy industrial control schemes, the MC-TAMR04 multiplexes multiple low-level input signals into a centralized processing stream, reducing cabling complexity while maintaining high signal integrity and measurement accuracy. Its construction adheres to strict industrial standards to ensure reliable performance inside standard control room marshaling cabinets or remote node enclosures.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDesigned for Honeywell TDC 3000 and legacy Experion\/DCS architecture environments\u003c\/li\u003e\n  \u003cli\u003ePrecision low-level signal multiplexing for thermocouple and millivolt inputs\u003c\/li\u003e\n  \u003cli\u003eReduces extensive field wiring by consolidating multiple sensor inputs\u003c\/li\u003e\n  \u003cli\u003eStandardized form factor for seamless rack or chassis mounting in industrial cabinets\u003c\/li\u003e\n  \u003cli\u003eBuilt to meet rigorous industrial operational and noise-immunity standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eChemical and petrochemical processing plants\u003c\/li\u003e\n  \u003cli\u003ePower generation facilities and turbine monitoring\u003c\/li\u003e\n  \u003cli\u003eRefining and oil \u0026amp; gas production units\u003c\/li\u003e\n  \u003cli\u003eLarge-scale continuous manufacturing and process control loops\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eHoneywell\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eExact Model \/ Part Number\u003c\/td\u003e\n      \u003ctd\u003eMC-TAMR04 \/ 51305907-175\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Series\u003c\/td\u003e\n      \u003ctd\u003eTDC 3000 \/ MU-T Series\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModule Type\u003c\/td\u003e\n      \u003ctd\u003eLow Level Input Multiplexer\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCompatible Control Systems\u003c\/td\u003e\n      \u003ctd\u003eHoneywell TDC 3000 DCS\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCountry of Origin\u003c\/td\u003e\n      \u003ctd\u003eUSA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNet Weight\u003c\/td\u003e\n      \u003ctd\u003e0.5 kg (Approximate)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eVerify that the control system power and associated field signal lines are fully de-energized before handling the module.\u003c\/li\u003e\n  \u003cli\u003eInspect the MC-TAMR04 51305907-175 unit for any transit damage or bent pins on the connector backplane interface.\u003c\/li\u003e\n  \u003cli\u003eMount the module securely into the designated slot within the system cabinet backplane or chassis.\u003c\/li\u003e\n  \u003cli\u003eConnect field wiring and signal terminations carefully, adhering to proper shielding and grounding practices to prevent electromagnetic interference.\u003c\/li\u003e\n  \u003cli\u003eRe-energize the system and verify module health and signal communication via the engineering workstation or controller diagnostics.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667738390891,"sku":"MC-TAMR04 51305907-175","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-mc-tamr04-51305907-175-low-level-input-multiplexer-groy30pkvux_c410eeb0-9325-4639-8a2f-baa960adbe58.jpg?v=1765501364"},{"product_id":"honeywell-cc-paim01-51405045-175-series-c-low-level-analog-input-multiplexer-module","title":"Honeywell CC-PAIM01 51405045-175 Series C Low Level Analog Input Multiplexer Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell CC-PAIM01\u003c\/strong\u003e (Part Number \u003cstrong\u003e51405045-175\u003c\/strong\u003e) is a Low Level Analog Input Multiplexer module designed for the Honeywell Experion PKS Series C I\/O architecture. Operating on a Series C IOLINK connection, the \u003cstrong\u003eCC-PAIM01\u003c\/strong\u003e processes low-level analog signals across 64 channels, providing high-density data acquisition capability for industrial process control and monitoring applications.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Channel Density:\u003c\/strong\u003e Provides 64 input channels for low-level analog signal multiplexing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries C Architecture:\u003c\/strong\u003e Integrates into Series C IOLINK communication networks managed by C300 controllers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunction Block Support:\u003c\/strong\u003e Uses the AI-LLMUX I\/O module function block.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHoneywell Experion PKS Series C Control Systems\u003c\/li\u003e\n\u003cli\u003eLow-level analog signal acquisition and process monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCC-PAIM01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e51405045-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Level Analog Input Mux Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIOM Block Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAI-LLMUX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSimilar PM I\/O Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLLMUX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Compatibility:\u003c\/strong\u003e Mount on a supported Series C IOTA and connect via a Series C IOLINK bus configured for Series C I\/O support.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFirmware Delivery:\u003c\/strong\u003e Executive software images and updates are delivered over the IOLINK connection.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667741471083,"sku":"CC-PAIM01 51405045-175","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-cc-paim01-51405045-175-analog-input-module-x3qchaykicg_10083573-fdef-407d-a757-2692b40c256c.jpg?v=1765501411"},{"product_id":"honeywell-8c-taox51-51306983-175-plantcruise-series-8-analog-output-iota","title":"Honeywell 8C-TAOX51 51306983-175 PlantCruise Series 8 Analog Output IOTA","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell 8C-TAOX51\u003c\/strong\u003e (part number \u003cstrong\u003e51306983-175\u003c\/strong\u003e) is a conformal-coated, non-redundant 6-inch Input Output Termination Assembly (\u003cstrong\u003eIOTA\u003c\/strong\u003e) designed for \u003cstrong\u003ePlantCruise Series 8\u003c\/strong\u003e process control systems. It combines field wiring termination and the Analog Output Input Output Module (\u003cstrong\u003eIOM\u003c\/strong\u003e) into a single compact area, eliminating the need for a separate electronics chassis. Operating directly from a 24 VDC carrier power bus, the unit delivers non-incendive field power distribution across 16 channels without requiring external marshalling or inline fusing. The assembly features two-level detachable screw terminals, integrated signal conditioning, and on-board connection to the I\/O Link for standard 4-20 mA and HART-capable analog output operations.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCombines field terminations and I\/O module mounting in a single unit, eliminating external chassis requirements.\u003c\/li\u003e\n\u003cli\u003eEquipped with two-level detachable terminal blocks for simple field wiring installation and maintenance.\u003c\/li\u003e\n\u003cli\u003eSupplies non-incendive field power directly through an integrated 24 VDC bus connection on the carrier.\u003c\/li\u003e\n\u003cli\u003eConformal coating protection (8C designator) against humidity, dust, chemicals, and temperature extremes.\u003c\/li\u003e\n\u003cli\u003eVertical mounting orientation and tilted physical layout engineered for cabinet space efficiency and heat management.\u003c\/li\u003e\n\u003cli\u003eShort-circuit protected output circuits that eliminate inline fusing needs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eField wiring termination and power distribution for 16-channel 4-20 mA analog output devices.\u003c\/li\u003e\n\u003cli\u003eInterfacing actuators, positioners, and recording instruments in Honeywell PlantCruise by Experion architectures.\u003c\/li\u003e\n\u003cli\u003eClass 1, Division 2 hazardous area deployments requiring non-incendive field power conditioning.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSize\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eRedundancy Support\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e8C-TAOX51\u003c\/td\u003e\n\u003ctd\u003eAO IOTA, Coated\u003c\/td\u003e\n\u003ctd\u003e6 in (152 mm)\u003c\/td\u003e\n\u003ctd\u003eNon-Redundant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e8C-TAOX61\u003c\/td\u003e\n\u003ctd\u003eAO IOTA, Coated\u003c\/td\u003e\n\u003ctd\u003e12 in (304 mm)\u003c\/td\u003e\n\u003ctd\u003eRedundant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e8U-TAOX51\u003c\/td\u003e\n\u003ctd\u003eAO IOTA, Uncoated\u003c\/td\u003e\n\u003ctd\u003e6 in (152 mm)\u003c\/td\u003e\n\u003ctd\u003eNon-Redundant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e8U-TAOX61\u003c\/td\u003e\n\u003ctd\u003eAO IOTA, Uncoated\u003c\/td\u003e\n\u003ctd\u003e12 in (304 mm)\u003c\/td\u003e\n\u003ctd\u003eRedundant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e8C-TAOX51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e51306983-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eInput Output Termination Assembly (IOTA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003ePlantCruise Series 8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Coating\u003c\/td\u003e\n\u003ctd\u003eConformal Coated (8C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIOTA Size\u003c\/td\u003e\n\u003ctd\u003eNominal 6 inches (152 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy\u003c\/td\u003e\n\u003ctd\u003eNon-Redundant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Channel Count\u003c\/td\u003e\n\u003ctd\u003e16 Circuits \/ Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Input\u003c\/td\u003e\n\u003ctd\u003e24 VDC bus (screw-mounted to carrier bus)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Power Distribution\u003c\/td\u003e\n\u003ctd\u003eNon-incendive output (no external field power required)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Connection Type\u003c\/td\u003e\n\u003ctd\u003eTwo-level detachable terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Wire Size\u003c\/td\u003e\n\u003ctd\u003eUp to 12 AWG \/ 2.5 mm2 stranded wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Output Modules\u003c\/td\u003e\n\u003ctd\u003e8C-PAOH51, 8U-PAOH51, 8C-PAON01, 8U-PAON01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Output Type\u003c\/td\u003e\n\u003ctd\u003e4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Ripple\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 100 mV peak-to-peak at power line frequency across 250 ohm load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.05% of Full Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibrated Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.35% of Full Scale (25 degC) including linearity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSettable Output Range\u003c\/td\u003e\n\u003ctd\u003e0 mA, 2.9 mA to 21.1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Open Circuit Voltage\u003c\/td\u003e\n\u003ctd\u003e22 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector \/ Interface\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetachable Field Terminals\u003c\/td\u003e\n\u003ctd\u003eTwo-level wiring terminals for 16-channel analog output field connections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarrier Bus Connection\u003c\/td\u003e\n\u003ctd\u003eMechanical screw connections for receiving 24 VDC system power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIOM Mounting Interface\u003c\/td\u003e\n\u003ctd\u003eDirect plug-in slot for Series 8 Analog Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Connection\u003c\/td\u003e\n\u003ctd\u003eIntegrated connection to I\/O Link network\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount vertically inside system cabinets to align with field wiring entry from cabinet top or bottom.\u003c\/li\u003e\n\u003cli\u003eEnsure natural ventilation by using the tilted hardware design for thermal dissipation.\u003c\/li\u003e\n\u003cli\u003eScrew the termination assembly directly onto the 24 VDC bussed power carrier.\u003c\/li\u003e\n\u003cli\u003eLand field wiring on the two-level detachable terminals using stranded conductors up to 12 AWG (2.5 mm2).\u003c\/li\u003e\n\u003cli\u003eVerify non-incendive wiring practices when installing in Class 1, Division 2 hazardous environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eClass 1, Division 2 Hazardous Location Non-Incendive Rating\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667742060907,"sku":"8C-TAOX51 51306983-175","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-8c-taox51-51306983-175-analog-output-module-ciqzsbg3qxx_30f39685-af58-4ab5-b322-2ab9e3eea638.jpg?v=1765501420"},{"product_id":"honeywell-experion-pks-fta-t-20-digital-output-relay-field-termination-assembly","title":"Honeywell Experion PKS FTA-T-20 Digital Output Relay Field Termination Assembly","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFTA-T-20\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a specialized Field Termination Assembly (FTA) within the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell Safety Manager (SMS)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eExperion PKS\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eecosystems. It serves as the physical and electrical interface between the system's digital output modules and the external field equipment.\u003c\/p\u003e\n\u003cp\u003eDesigned for high-load or isolated switching requirements, the FTA-T-20 provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8 channels of relay-contact outputs\u003c\/strong\u003e. Each channel offers\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNO (Normally Open)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNC (Normally Closed)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econtacts, allowing for flexible fail-safe configurations. By utilizing interposing relays on the FTA, the system protects the sensitive controller electronics from field-side electrical surges and allows the switching of higher voltages and currents (up to 250 Vac or 110 Vdc) than a standard electronic output could handle.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe FTA-T-20 is engineered for seamless integration into Honeywell safety and control racks:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChannel Density:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e8 independent relay channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eContact Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSPDT (Single Pole Double Throw) configuration, providing both NO and NC terminals for every channel.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInterface Connection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConnects to the controller I\/O module via a standard\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSIC-C-07\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esystem interconnection cable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eField Wiring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEquipped with robust\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003escrew terminals\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor direct connection of field cables, supporting a variety of wire gauges.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard DIN-rail mounting for installation in I\/O cabinets or marshalling panels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNFS (Non-Fail Safe) Design:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTypically used in applications where the safety logic is managed by the controller, and the relay acts as the final switching element.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFTA-T-20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDigital Output (Relay Contact)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax Switching Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e250 Vac \/ 110 Vdc\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eContact Logic\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNO \/ NC (Change-over)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInterconnection Cable\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSIC-C-07\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTerminal Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eScrew Terminals (T-Type)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Reference\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10209\/2\/1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e~0.8 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the advantage of using an FTA-T (Screw Terminal) over an FTA-E (ELCO)?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFTA-T\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eversion is designed for direct field wiring where the cables are terminated individually at the assembly. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFTA-E\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(ELCO) version is typically used for \"marshalling-to-marshalling\" connections using pre-fabricated multi-core cables. The FTA-T-20 is ideal for cabinets where field sensors\/actuators are wired directly to the I\/O rack.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I mix AC and DC loads on the same FTA-T-20?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the relay contacts are rated for both 250 Vac and 110 Vdc, it is standard engineering practice to keep load types consistent across an FTA to prevent noise and to simplify maintenance. However, since the 8 channels are galvanically isolated from each other, they can technically switch different voltage sources.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I replace a faulty relay on this FTA?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDepending on the specific hardware revision, the relays on the FTA-T-20 are often socket-mounted. This allows for \"hot-maintenance\" where an individual relay can be replaced without replacing the entire termination assembly or disturbing the wiring of the other 7 channels.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWire Termination:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure that wire ferrules are used when connecting to the screw terminals. This prevents wire fraying and ensures a gas-tight connection, which is critical in corrosive industrial environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCable Routing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSIC-C-07\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecable should be routed away from high-power AC lines to prevent induced noise, even though the relay outputs are relatively robust.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eContact Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFor highly inductive loads (such as large solenoid valves or motor starters), it is recommended to install external RC snubbers (for AC) or flyback diodes (for DC) to extend the life of the FTA relay contacts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFusing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAlways ensure that field-side circuits are properly fused. The FTA-T-20 provides the switching logic, but the current-limiting protection should be handled by external terminal fuses or circuit breakers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667743338859,"sku":"FTA-T-20","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-fta-t-20-fta-output-module-qqfm5mreu3l_e04138f4-fd7c-4a5d-9cc3-0b76caa2f4a1.jpg?v=1765501439"},{"product_id":"honeywell-51306975-175-digital-output-module-experion-pks","title":"Honeywell 51306975-175 Digital Output Module Experion PKS","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell 51306975-175 is a high-performance digital output module designed specifically for integration within the Honeywell Experion Process Knowledge System (PKS) architecture. This hardware component serves a critical role in industrial automation and distributed control systems (DCS), acting as the direct interface for sending discrete control signals from the controller to field actuators, solenoids, indicator lamps, and binary-driven control devices. Engineered to meet rigorous industrial standards, the module ensures reliable execution of interlocking logic, sequential control routines, and emergency shutdown procedures within continuous process manufacturing environments.\u003c\/p\u003e\n\u003cp\u003eAs part of the Series C and compatible Experion PKS platform infrastructure, the 51306975-175 digital output module facilitates seamless data exchange and power distribution across system nodes. Its robust electronic design minimizes signal degradation and optimizes loop response times, contributing to overall plant safety and operational efficiency. The module integrates directly into standard chassis layouts, communicating internal status diagnostics back to the central processing architecture for real-time system monitoring and preventive maintenance planning.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eNative integration with Honeywell Experion PKS distributed control system architecture\u003c\/li\u003e\n  \u003cli\u003eProvides reliable digital output signal generation for discrete field devices and actuators\u003c\/li\u003e\n  \u003cli\u003eSupports system-level diagnostics and real-time status reporting for enhanced loop reliability\u003c\/li\u003e\n  \u003cli\u003eHot-swappable hardware design allows for replacement without interrupting overall process control operations\u003c\/li\u003e\n  \u003cli\u003eStandardized form factor engineered for efficient cabinet space utilization and secure chassis mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOil and gas extraction, refining, and petrochemical processing plants\u003c\/li\u003e\n  \u003cli\u003eChemical synthesis and continuous pharmaceutical manufacturing facilities\u003c\/li\u003e\n  \u003cli\u003ePower generation plants and electrical utility distribution systems\u003c\/li\u003e\n  \u003cli\u003eWater and wastewater treatment infrastructure monitoring\u003c\/li\u003e\n  \u003cli\u003ePulp, paper, and heavy industrial automation production lines\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eHoneywell\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Family\u003c\/td\u003e\n      \u003ctd\u003eExperion PKS\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eExact Model \/ SKU\u003c\/td\u003e\n      \u003ctd\u003e51306975-175\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModule Type\u003c\/td\u003e\n      \u003ctd\u003eDigital Output Module\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSystem Platform\u003c\/td\u003e\n      \u003ctd\u003eDistributed Control System (DCS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCountry of Origin\u003c\/td\u003e\n      \u003ctd\u003eUnited States\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNet Weight\u003c\/td\u003e\n      \u003ctd\u003e0.26 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDimensions\u003c\/td\u003e\n      \u003ctd\u003e220 mm x 120 mm x 15 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eVerify the exact model number (51306975-175) against system engineering documentation before beginning installation.\u003c\/li\u003e\n  \u003cli\u003eEnsure that power to the target chassis slot is de-energized to prevent electrical shock or hardware damage.\u003c\/li\u003e\n  \u003cli\u003eInspect the module and terminal connections for any signs of transit damage or environmental contamination.\u003c\/li\u003e\n  \u003cli\u003eAlign the module securely with the designated slot guides on the Experion PKS chassis and push gently until fully seated.\u003c\/li\u003e\n  \u003cli\u003eFasten any integrated locking mechanisms or mounting screws to maintain a stable physical and electrical connection.\u003c\/li\u003e\n  \u003cli\u003eRestore system power and verify module recognition, communication status, and channel functionality via the Experion configuration software.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667743797611,"sku":"51306975-175","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-51306975-175-digital-output-module-v2bkex5e3z3_1d265157-d3be-4b93-bf10-c6d910e9ad2d.jpg?v=1765501447"},{"product_id":"honeywell-cc-paon01-51410070-175-experion-pks-series-c-non-hart-analog-output-module","title":"Honeywell CC-PAON01 51410070-175 Experion PKS Series C Non-HART Analog Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell CC-PAON01\u003c\/strong\u003e (Part Number \u003cstrong\u003e51410070-175\u003c\/strong\u003e) is a 16-channel non-HART analog output module engineered for process automation applications within the Honeywell Experion Process Knowledge System (PKS) Series C architecture. Operating on the Series C I\/O link (IOLINK) mastered by a C300 controller, the module delivers 4-20 mA control signals to field elements such as control valves, actuators, positioners, and variable speed drives.\u003c\/p\u003e\n\u003cp\u003eDesigned as an updated functional successor to earlier CC-PAOX01 and CU-PAOX01 hardware models, the \u003cstrong\u003eCC-PAON01\u003c\/strong\u003e utilizes the standard AO16 function block in Experion Control Builder. The module mounts directly onto dedicated Series C Input Output Termination Assemblies (IOTA), integrating into single or redundant IOLINK topographies.\u003c\/p\u003e\n\u003cp\u003eIn Experion PKS control architectures, the \u003cstrong\u003eCC-PAON01\u003c\/strong\u003e supports both non-redundant and 1-on-1 redundant hardware configurations. Following localized power disruptions, single I\/O modules complete initialization in 10 seconds (+\/- 25%), resuming control loop processing without requiring full system reboots.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProvides 16 analog output channels dedicated to non-HART 4-20 mA field control loops.\u003c\/li\u003e\n\u003cli\u003eInterfaces directly with C300 controllers over the Series C I\/O link (IOLINK) network.\u003c\/li\u003e\n\u003cli\u003eConfigured and executed in Experion Control Builder using the standard AO16 IOM block structure.\u003c\/li\u003e\n\u003cli\u003eServes as the direct functional replacement model for legacy CC-PAOX01 and CU-PAOX01 modules.\u003c\/li\u003e\n\u003cli\u003eSupports non-redundant (CC-TAON01) and redundant (CC-TAON11) Field Termination Assemblies.\u003c\/li\u003e\n\u003cli\u003eRapid module-level initialization completes within 10 seconds (+\/- 25%) following power restoration.\u003c\/li\u003e\n\u003cli\u003eSupports up to 40 redundant IOMs per IOLINK and up to 80 redundant IOMs per C300 controller.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eModulating final control elements including 4-20 mA control valves, I\/P converters, and positioners.\u003c\/li\u003e\n\u003cli\u003eProviding analog control speed references to variable frequency drives (VFD) and motor controllers.\u003c\/li\u003e\n\u003cli\u003eIntegrating non-HART analog output field loops into Experion PKS C300 process automation systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003eCC-PAON01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e51410070-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eSeries C Non-HART Analog Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl System Compatibility\u003c\/td\u003e\n\u003ctd\u003eExperion PKS Series C \/ C300 Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e16 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Output Type\u003c\/td\u003e\n\u003ctd\u003e4-20 mA (Non-HART)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction Block Type\u003c\/td\u003e\n\u003ctd\u003eAO16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Non-Redundant IOTA\u003c\/td\u003e\n\u003ctd\u003eCC-TAON01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Redundant IOTA\u003c\/td\u003e\n\u003ctd\u003eCC-TAON11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Communication Interface\u003c\/td\u003e\n\u003ctd\u003eSeries C IOLINK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Modules per IOLINK\u003c\/td\u003e\n\u003ctd\u003e40 redundant IOMs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Modules per C300 Controller\u003c\/td\u003e\n\u003ctd\u003e80 redundant IOMs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle Module Initialization Time\u003c\/td\u003e\n\u003ctd\u003e10 seconds (+\/- 25%) after module power restoration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet-Level Initialization Time\u003c\/td\u003e\n\u003ctd\u003e60 seconds (+\/- 25%) after cabinet power restoration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuperseded Models\u003c\/td\u003e\n\u003ctd\u003eCC-PAOX01, CU-PAOX01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eAssembly Type\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-Redundant IOTA\u003c\/td\u003e\n\u003ctd\u003eCC-TAON01\u003c\/td\u003e\n\u003ctd\u003eSingle-channel field termination assembly for CC-PAON01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundant IOTA\u003c\/td\u003e\n\u003ctd\u003eCC-TAON11\u003c\/td\u003e\n\u003ctd\u003eDual-channel redundant field termination assembly for CC-PAON01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eVerify that the module model (CC-PAON01) and part number (51410070-175) match engineering design drawings before installation.\u003c\/li\u003e\n\u003cli\u003eConfirm cabinet logic power status and observe ESD protection procedures before handling the module assembly.\u003c\/li\u003e\n\u003cli\u003eAlign the rear connector of the CC-PAON01 with the designated slot on the CC-TAON01 or CC-TAON11 IOTA base.\u003c\/li\u003e\n\u003cli\u003ePress the module onto the IOTA mounting position until the securing latches click into place.\u003c\/li\u003e\n\u003cli\u003eInspect field wiring connected to the IOTA screw terminals to ensure secure wire termination and shielding ground connections.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eConfiguration \/ Commissioning \/ Replacement Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eBlock Assignment\u003c\/strong\u003e: In Experion Control Builder, assign the channel configuration using the standard AO16 function block.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLink Configuration\u003c\/strong\u003e: Ensure the C300 controller IOLINKTYPE parameter is set correctly to support Series C I\/O modules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy Restrictions\u003c\/strong\u003e: When replacing older CC-PAOX01 units with CC-PAON01, note that mixed redundant pairs (pairing a PAOX01 with a PAON01) are not supported; online migration requires identical hardware pairs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommissioning Verification\u003c\/strong\u003e: Measure loop current across the output terminals using a calibrated meter prior to placing the corresponding control loop into automatic mode.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667744911723,"sku":"CC-PAON01 51410070-175","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-cc-paon01-51410070-175-analog-output-module-15ttl14pgnq_6f9cb4a6-3951-407d-89e5-d605928abeb7.jpg?v=1765501464"},{"product_id":"honeywell-bc-thai11-42622268-002-experion-pks-i-o-output-module","title":"Honeywell BC-THAI11 42622268-002 Experion PKS I\/O Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell BC-THAI11 (model 42622268-002) is a specialized I\/O module designed for integration within the Honeywell Experion Process Knowledge System (PKS) architecture. This hardware component serves as a dedicated interface for handling output signals, facilitating reliable communication and control between field-level final control elements and the centralized distributed control system (DCS).\u003c\/p\u003e\n\u003cp\u003eEngineered for industrial process control environments, the BC-THAI11 module enables deterministic data exchange and execution of control strategies. It mounts onto standard system chassis infrastructure within Experion PKS cabinets, interfacing directly with local power distribution and system backplanes to deliver structured input\/output management for continuous and batch automation applications.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eNative integration with Honeywell Experion PKS distributed control architectures\u003c\/li\u003e\n  \u003cli\u003eDesigned for reliable signal output management in industrial DCS networks\u003c\/li\u003e\n  \u003cli\u003eStandardized form factor for DIN rail or proprietary system chassis mounting\u003c\/li\u003e\n  \u003cli\u003eDiagnostic indicators for module status, power, and communication health\u003c\/li\u003e\n  \u003cli\u003eHot-swappable design capability depending on system cabinet architecture\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eContinuous process manufacturing and petrochemical refining\u003c\/li\u003e\n  \u003cli\u003ePower generation and distribution control systems\u003c\/li\u003e\n  \u003cli\u003ePharmaceutical production and bioprocessing facilities\u003c\/li\u003e\n  \u003cli\u003eWater and wastewater treatment automation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eHoneywell\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Model\u003c\/td\u003e\n      \u003ctd\u003eBC-THAI11\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCatalog \/ Ordering Number\u003c\/td\u003e\n      \u003ctd\u003e42622268-002\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSystem Family\u003c\/td\u003e\n      \u003ctd\u003eExperion PKS\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003eI\/O Output Module\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCountry of Origin\u003c\/td\u003e\n      \u003ctd\u003eUnited States\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eVerify that the part number BC-THAI11 42622268-002 matches system engineering documentation prior to physical deployment.\u003c\/li\u003e\n  \u003cli\u003eDe-energize the target system chassis slot and associated power supplies before handling hardware.\u003c\/li\u003e\n  \u003cli\u003eInspect the module and backplane connectors for any signs of physical damage or debris.\u003c\/li\u003e\n  \u003cli\u003eSecurely insert the module into the designated slot within the Experion PKS I\/O chassis, ensuring proper alignment with the backplane pins.\u003c\/li\u003e\n  \u003cli\u003eFasten any retaining screws or locking mechanisms according to mechanical specifications.\u003c\/li\u003e\n  \u003cli\u003eRestore power and verify module health through the Experion Station engineering interface.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667745010027,"sku":"BC-THAI11 42622268-002","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-bc-thai11-42622268-002-i-o-output-module-2kwz33dizpu_1ce306ce-8f32-4529-98ab-0913e1d27343.jpg?v=1765501465"},{"product_id":"honeywell-mu-tamt02-51401491-100-high-process-manager-llmux-tc-fta","title":"Honeywell MU-TAMT02 51401491-100 High Process Manager LLMux TC FTA","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell MU-TAMT02 51401491-100\u003c\/strong\u003e is a Low Level Analog Input Multiplexer Thermocouple (LLMux TC) Field Termination Assembly (FTA) designed for use within the Honeywell High Process Manager (HPM) subsystem. The \u003cstrong\u003eMU-TAMT02\u003c\/strong\u003e serves as the physical field interface for low-level analog input signals coming from thermocouples, routing these field signals directly to the Process Manager I\/O Processors (IOP) via dedicated FTA cabling. Featuring a non-conformally coated assembly construction, the \u003cstrong\u003e51401491-100\u003c\/strong\u003e FTA provides reliable termination, signal routing, and interface integrity for temperature monitoring in industrial automation and DCS control applications.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for Low Level Analog Input Multiplexer Thermocouple (LLMux TC) signal processing\u003c\/li\u003e\n\u003cli\u003eNon-conformally coated printed circuit board assembly\u003c\/li\u003e\n\u003cli\u003eDirect field wiring interface for thermocouple temperature sensors\u003c\/li\u003e\n\u003cli\u003eServes as standard Non-CE Compliant Field Termination Assembly (FTA)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDistributed Control Systems (DCS) process control\u003c\/li\u003e\n\u003cli\u003eThermocouple temperature input signal termination and multiplexing\u003c\/li\u003e\n\u003cli\u003eIndustrial process automation and monitoring in High Process Manager (HPM) systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003eMU-TAMT02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e51401491-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eLLMux TC FTA (Low Level Multiplexer Thermocouple Field Termination Assembly)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eHigh Process Manager (HPM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoating\u003c\/td\u003e\n\u003ctd\u003eNon-conformally Coated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Compliance\u003c\/td\u003e\n\u003ctd\u003eNon-CE Compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure system power is disconnected before installing or removing the Field Termination Assembly.\u003c\/li\u003e\n\u003cli\u003eRoute field wiring and thermocouple signal cables separately from high-voltage AC cables to minimize electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eMaintain proper shield grounding practices at designated ground terminals on the assembly to preserve signal accuracy.\u003c\/li\u003e\n\u003cli\u003eEnsure adequate enclosure cabinet ventilation to maintain operating temperature limits.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667746845035,"sku":"MU-TAMT02 51401491-100","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-mu-tamt02-51401491-100-low-level-analog-input-multiplexer-aufpf5vmdmd_86f2c872-8343-4363-8f77-cd1a6e93b776.jpg?v=1765501496"},{"product_id":"honeywell-mc-taih02-51304453-150-tps-process-manage-high-level-analog-input-sti-fta","title":"Honeywell MC-TAIH02 51304453-150 TPS Process Manage High Level Analog Input\/STI FTA","description":"\u003cp\u003eThe Honeywell \u003cstrong\u003eMC-TAIH02\u003c\/strong\u003e is a High Level Analog Input \/ Smart Transmitter Interface Field Termination Assembly (FTA) designed for process signal termination and field wiring interfacing within TotalPlant Solution (TPS) Process Manager systems.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAccommodates up to 16 differential input channels for analog voltage\/current signals or digital smart transmitter communications.\u003c\/li\u003e\n\u003cli\u003eIntegrates resistor current limiting (145 ohm, non-fused) for transmitter power conditioning in Class 1, Div 2 hazardous location interfacing.\u003c\/li\u003e\n\u003cli\u003eFeatures compression-type termination blocks capable of accepting wire sizes up to 14 AWG (~1.6 mm).\u003c\/li\u003e\n\u003cli\u003eSupports high-density A-size assembly footprint for cabinet space efficiency.\u003c\/li\u003e\n\u003cli\u003eProvided with standard conformal coating for harsh environment and corrosion protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-level analog voltage and current field loop terminations\u003c\/li\u003e\n\u003cli\u003eSmart Transmitter Interface (DE protocol) field device wiring\u003c\/li\u003e\n\u003cli\u003eProcess Manager (PM), Advanced Process Manager (APM), High Performance Process Manager (HPM), and Enhanced High Performance Process Manager (EHPM) I\/O subsystems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMC-TAIH02\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e51304453-150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBase Model Equivalent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMU-TAIH02 (Conformally Coated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 differential channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible IOP Modules\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMC-PAIH03, MU-PSTX03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Signal Types\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVoltage, current (2-wire or self-powered), Honeywell DE protocol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmitter Power Conditioning\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResistor Current Limited (145 ohm, not fused)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Block Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCompression-Type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Wire Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 AWG (~1.6 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFTA Assembly Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSize A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConformally Coated (G3 \/ Harsh Atmosphere rating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSurge Withstand Capability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eANSI\/IEEE C37.90.1-1978\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Wiring Connection:\u003c\/strong\u003e Route field wiring to the compression terminals ensuring conductors do not exceed 14 AWG (~1.6 mm).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Common Reference:\u003c\/strong\u003e The low-side input connection is normally connected to system common via a wire jumper on the FTA, which can be removed subject to operating within Common Mode Voltage limits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Routing:\u003c\/strong\u003e Connect the FTA to the corresponding Input\/Output Processor (IOP) using approved Honeywell FTA cables up to 50 meters in length.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCorrosion Protection:\u003c\/strong\u003e Maintain conformal coating integrity when installed in non-G1 process environments.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667747041643,"sku":"MC-TAIH02 51304453-150","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/MC-TAIH02-51304453-150_001_1200x1200_8abf2705-8fd1-4415-8072-1ee73a4082cf.jpg?v=1786518694"},{"product_id":"honeywell-8c-paoha1-51454469-275-analog-output-module","title":"Honeywell 8C-PAOHA1 51454469-275 Analog Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell 8C-PAOHA1 (Model 51454469-275) is a high-density analog output module engineered for Honeywell Experion Process Knowledge System (PKS) architectures. As part of the Series C platform, this hardware interfaces the control system with final control elements such as control valves, actuators, and variable speed drives by converting controller digital values into precise analog current signals. Its space-saving form factor optimizes cabinet footprint while delivering reliable process control across demanding industrial installations.\u003c\/p\u003e\n\u003cp\u003eThe module is designed to mount on standard Series C I\/O carriers and connects directly to the system architecture via redundant I\/O communication links. It handles multi-channel analog output distribution with built-in channel-level diagnostics, supporting continuous supervision of loop integrity and device health. This minimizes manual troubleshooting and helps maintain uninterrupted process operation.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSeries C I\/O form factor designed for high-density cabinet layouts\u003c\/li\u003e\n  \u003cli\u003ePrecision analog output channels for actuators, positioners, and modulating valves\u003c\/li\u003e\n  \u003cli\u003eIntegrated diagnostic monitoring for open-circuit and short-circuit detection\u003c\/li\u003e\n  \u003cli\u003eDirect insertion mounting on Series C I\/O termination assemblies\u003c\/li\u003e\n  \u003cli\u003eSupports redundant module configurations for high-availability control strategies\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOil and gas extraction and refining facilities\u003c\/li\u003e\n  \u003cli\u003eChemical and petrochemical processing plants\u003c\/li\u003e\n  \u003cli\u003ePower generation and utility boiler controls\u003c\/li\u003e\n  \u003cli\u003eWater and wastewater treatment installations\u003c\/li\u003e\n  \u003cli\u003eLarge-scale continuous manufacturing process control\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eHoneywell\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Series\u003c\/td\u003e\n      \u003ctd\u003eExperion PKS \/ Series C\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eExact Model \/ Part Number\u003c\/td\u003e\n      \u003ctd\u003e8C-PAOHA1 (51454469-275)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModule Type\u003c\/td\u003e\n      \u003ctd\u003eAnalog Output Module\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMounting Type\u003c\/td\u003e\n      \u003ctd\u003eSeries C I\/O Carrier\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd\u003e0 to 60 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStorage Temperature\u003c\/td\u003e\n      \u003ctd\u003e-40 to 85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRelative Humidity\u003c\/td\u003e\n      \u003ctd\u003e5 to 95 percent, non-condensing\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCountry of Origin\u003c\/td\u003e\n      \u003ctd\u003eUSA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNet Weight\u003c\/td\u003e\n      \u003ctd\u003e0.3 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDimensions\u003c\/td\u003e\n      \u003ctd\u003e6.0 cm x 15.6 cm x 14.3 cm\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eVerify part numbers and inspect the module and Series C carrier for any shipping damage before installation.\u003c\/li\u003e\n  \u003cli\u003eEnsure all power to the target I\/O slot and associated field wiring terminal blocks is de-energized.\u003c\/li\u003e\n  \u003cli\u003eSlide the 8C-PAOHA1 module straight into the designated Series C I\/O carrier slot, taking care not to bend backplane pins.\u003c\/li\u003e\n  \u003cli\u003eSecure the module using the integrated locking mechanism according to hardware specifications.\u003c\/li\u003e\n  \u003cli\u003eVerify field wiring terminations on the I\/O termination assembly before restoring system power.\u003c\/li\u003e\n  \u003cli\u003ePower up the node and use Experion Engineering Station tools to verify module recognition and channel configuration.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667747565931,"sku":"8C-PAOHA1 51454469-275","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-8c-paoha1-51454469-275-analog-output-module-2vsfnn1ntrq_44596505-7697-4ad4-a887-1b2604c72629.jpg?v=1765501508"},{"product_id":"honeywell-51109693-100b-universal-control-network-ucn-4-port-drop-cable-tap-ground-module","title":"Honeywell 51109693-100B Universal Control Network (UCN) 4-Port Drop Cable Tap Ground Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell 51109693-100B\u003c\/strong\u003e is a specialized network interface components designed for the Universal Control Network (UCN) within legacy TotalPlant Solution (TPS) and TDC 3000 Distributed Control Systems (DCS). This module serves as a ruggedized \u003cstrong\u003e4-port drop cable tap ground block\u003c\/strong\u003e, facilitating secure coax interface coupling and precise grounding infrastructure for critical high-speed control data lines.\u003c\/p\u003e\n\u003cp\u003eEngineered strictly for harsh industrial control environments, the \u003cstrong\u003e51109693-100B\u003c\/strong\u003e establishes robust branch connections from the primary UCN trunk line to individual nodes such as High-Performance Process Managers (HPM), Network Interface Modules (NIM), or Advanced Process Managers (APM). By providing high-integrity shielding terminations and static discharge paths, the module actively prevents common-mode noise propagation, ground-loop disruptions, and signal attenuation along the network segment. Its industrial-grade passive architecture ensures uninterrupted physical layer operations and uniform impedance matching necessary for continuous multi-node industrial process synchronization.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFeatures an integrated \u003cstrong\u003e4-port drop cable connection\u003c\/strong\u003e infrastructure enabling dual or multi-node transceiver drops from a localized point.\u003c\/li\u003e\n\u003cli\u003eIncorporates a dedicated low-resistance grounding bus bar interface to drain induced EMI\/RFI interference away from coax cores.\u003c\/li\u003e\n\u003cli\u003eMaintains strict physical layer attenuation parameters to ensure signal integrity across extended TDC 3000 network topologies.\u003c\/li\u003e\n\u003cli\u003eDesigned with heavy-duty cast aluminum or specialized shielding material to shield inner high-frequency junctions from ambient industrial noise.\u003c\/li\u003e\n\u003cli\u003eEmploys tight-tolerance BNC or specialized coax termination mechanisms minimizing insertion losses and reflection coefficients.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDistributed Control System (DCS) physical layer installation in petrochemical plants and oil refineries running Honeywell TDC 3000 \/ TPS platforms.\u003c\/li\u003e\n\u003cli\u003eSpecialized grounding and drop distribution for high-reliability communications between HPM subsystems and Network Interface Modules (NIM).\u003c\/li\u003e\n\u003cli\u003ePower generation utility networks requiring isolated and noise-immune fieldbus topologies across long physical distances.\u003c\/li\u003e\n\u003cli\u003ePulp, paper, and heavy manufacturing processing lines utilizing legacy coaxial-based corporate process control infrastructures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e51109693-100B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAlternative Part Identifier\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e51201395-100 Kit Reference\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUniversal Control Network (UCN) Drop Cable Tap Ground Block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePort Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4-Port Distribution \/ Drop Capacity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCoaxial Cable Trunk Line Drop Tap\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhysical Dimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12.0 cm x 9.8 cm x 4.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.24 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHousing Construction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHigh-density shielded industrial enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Pin\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrunk In\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePrimary Coaxial UCN Cable Input Segment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrunk Out\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContinuous Primary Coaxial UCN Cable Output Continuation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDrop Port 1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNode Branch Drop Line Connection 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDrop Port 2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNode Branch Drop Line Connection 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDrop Port 3\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNode Branch Drop Line Connection 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDrop Port 4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNode Branch Drop Line Connection 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGND Stud\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMain Earth Reference Low-Impedance Grounding Connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding Requirements\u003c\/strong\u003e: Secure the main external ground lug directly to the local instrumentation clean ground bus bar via a low-impedance braided copper strap. Avoid chaining ground paths across multiple separate mechanical frames.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding and EMI Isolation\u003c\/strong\u003e: Ensure complete coaxial outer shield continuity through the terminal clamps to prevent RF leakage and high-frequency common-mode industrial noise entry.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Routing Precautions\u003c\/strong\u003e: Route incoming and outgoing trunk cables through dedicated low-voltage data conduits, maintaining a minimum 300mm clearance from high-voltage AC supply lines or variable frequency drive outputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDrop Cable Bend Radius\u003c\/strong\u003e: Adhere strictly to the OEM coax specifications regarding minimum bend radii during installation inside local field marshaling panels to prevent structural dielectric deformation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the core function of the 51109693-100B within a Honeywell DCS network?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module acts as a localized 4-port drop junction and signal grounding block on the Universal Control Network, linking primary coax trunks to node transceivers without degrading impedance characteristics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this unit require external active power loops to run?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, this is an entirely passive mechanical and electrical interface unit designed for signal division, impedance maintenance, and grounding mitigation across coaxial lines.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan unused drop ports be left open during active system runtime?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, all unused drop terminals on active network lines should be fitted with compatible high-frequency impedance terminators to avoid signal reflections and potential frame corruption errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat mounting orientation is ideal for maximizing environmental resilience?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module should be mounted inside a dust-proof NEMA\/IP-rated control enclosure, preferably with the drop connectors facing downwards to avoid moisture ingress or debris accumulation within the female barrels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667749532011,"sku":"51109693-100B","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-51109693-100b-bracket-un3vk2whkyz_3aa2fb77-65e2-41d3-9b7d-adeb1d10bc9a.jpg?v=1765501531"},{"product_id":"honeywell-mc-pdiy22-80363972-100-digital-input-module","title":"Honeywell MC-PDIY22 80363972-100 Digital Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell MC-PDIY22, part number 80363972-100, is a high-performance digital input module engineered specifically for Honeywell TDC 3000 distributed control system architectures. This specialized hardware component functions as a critical interface between plant-floor discrete devices and the central control system, reliably acquiring binary signals from field instruments such as limit switches, proximity sensors, pushbuttons, and auxiliary relay contacts.\u003c\/p\u003e\n\u003cp\u003eDesigned for deployment within industrial control cabinets, the MC-PDIY22 processes incoming discrete voltage states and translates them into actionable data for supervisory control and logic execution. Its integration within the TDC 3000 platform guarantees dependable performance, strict compatibility with legacy architecture, and seamless communication across the control network.\u003c\/p\u003e\n\u003cp\u003eEquipped with internal diagnostic capabilities, the module continuously monitors channel health and hardware status, relaying diagnostic alerts to the control system to assist maintenance personnel in identifying loop faults, wiring breaks, or module anomalies before process disruptions occur.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eNative integration with Honeywell TDC 3000 distributed control systems\u003c\/li\u003e\n  \u003cli\u003eReliable acquisition and processing of multi-channel discrete input signals\u003c\/li\u003e\n  \u003cli\u003eBuilt-in hardware diagnostics for real-time fault detection and status reporting\u003c\/li\u003e\n  \u003cli\u003eStandardized form factor designed for efficient cabinet space utilization and backplane mounting\u003c\/li\u003e\n  \u003cli\u003eOptically isolated input channels to protect internal circuitry from field transients and electrical noise\u003c\/li\u003e\n  \u003cli\u003eConstructed for continuous-duty operation in demanding industrial process environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOil and gas production and refining facilities\u003c\/li\u003e\n  \u003cli\u003eChemical processing and petrochemical plants\u003c\/li\u003e\n  \u003cli\u003eElectric power generation stations\u003c\/li\u003e\n  \u003cli\u003eContinuous pulp and paper manufacturing lines\u003c\/li\u003e\n  \u003cli\u003eLarge-scale water and wastewater treatment facilities\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eHoneywell\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Series\u003c\/td\u003e\n      \u003ctd\u003eTDC 3000\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModel \/ Ordering Number\u003c\/td\u003e\n      \u003ctd\u003eMC-PDIY22\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePart Number\u003c\/td\u003e\n      \u003ctd\u003e80363972-100\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003eDigital Input Module\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n      \u003ctd\u003eHoneywell TDC 3000 DCS\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInput Type\u003c\/td\u003e\n      \u003ctd\u003eDiscrete \/ Digital Input\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCountry of Origin\u003c\/td\u003e\n      \u003ctd\u003eUSA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNet Weight\u003c\/td\u003e\n      \u003ctd\u003e0.58 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDimensions\u003c\/td\u003e\n      \u003ctd\u003eStandard TDC 3000 module envelope\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eVerify that the part number on the module packaging matches the 80363972-100 ordering specification for your system architecture.\u003c\/li\u003e\n  \u003cli\u003eEnsure all power to the target TDC 3000 cabinet slot and associated backplane segments is fully de-energized before handling hardware.\u003c\/li\u003e\n  \u003cli\u003eInspect the module edge connectors, pins, and housing for any signs of shipping damage or environmental contamination.\u003c\/li\u003e\n  \u003cli\u003eAlign the MC-PDIY22 module carefully with the designated backplane guides and push evenly until firmly seated.\u003c\/li\u003e\n  \u003cli\u003eSecure any module retention screws or locking mechanisms according to standard cabinet assembly practices.\u003c\/li\u003e\n  \u003cli\u003eEnergize the system and verify module recognition, status LED indicators, and communication health through the TDC 3000 engineering station.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667750252907,"sku":"MC-PDIY22 80363972-100","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-mc-pdiy22-80363972-100-digital-input-processor-module-orfbblutnjn_2259e397-4eb9-4ea4-bbde-16eebdf9299c.jpg?v=1765501542"},{"product_id":"honeywell-tk-orc161-97180373-chassis-series-a-isolated-discrete-relay-module","title":"Honeywell TK-ORC161 97180373 Chassis Series-A Isolated Discrete Relay Module","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell TK-ORC161\u003c\/strong\u003e is a conformal-coated, 16-point isolated discrete relay output module designed for the Experion Chassis Series-A (CIOM-A) I\/O platform. The device operates within Experion LS systems in conjunction with C200E\/C200 control processors over the I\/O ControlNet network. Featuring 16 individually isolated Normally Open (N.O.) relay contacts, the module provides high-density discrete output switching capabilities for a wide variety of field devices, loads, and industrial control applications.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConformal Coating:\u003c\/strong\u003e Includes factory-applied conformal coating (TK series) for enhanced corrosion protection in harsh industrial environments (ANSI\/ISA-S71.04-1985 Moderate G2 or Harsh G3 classification).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Density Channel Count:\u003c\/strong\u003e Equipped with 16 N.O. relay contact output channels in a single-wide chassis slot form factor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndividual Galvanic Isolation:\u003c\/strong\u003e Provides point-to-point channel isolation (16 N.O. contacts individually isolated) to ensure electrical independence and signal integrity across field circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVersatile Switching Capacities:\u003c\/strong\u003e Handles switching voltages from 10 to 265 VAC (47-63 Hz) and 5 to 150 VDC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfigurable Channel States:\u003c\/strong\u003e Features user-configurable Fault States and Program Mode states per point (Hold Last State, ON, or OFF; default is OFF).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHot-Swappable:\u003c\/strong\u003e Supports Removal and Insertion Under Power (RIUP) in non-hazardous\/ordinary locations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMotor starter control circuits\u003c\/li\u003e\n\u003cli\u003eSolenoid valve actuation\u003c\/li\u003e\n\u003cli\u003eAnnunciator panels and alarm indication outputs\u003c\/li\u003e\n\u003cli\u003eHigh-voltage interlock and isolation switching\u003c\/li\u003e\n\u003cli\u003eInterfacing field actuators with C200E\/C200 Control Processors in process control systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTK-ORC161\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 N.O. (Contacts individually isolated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 to 265 VAC (47-63 Hz) \/ 5 to 150 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage Range (Load Dependent)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e5-30 VDC @ 2.0 A resistive\u003c\/p\u003e\n\u003cp\u003e48 VDC @ 0.5 A resistive\u003c\/p\u003e\n\u003cp\u003e125 VDC @ 0.25 A resistive\u003c\/p\u003e\n\u003cp\u003e125 VAC @ 2.0 A resistive\u003c\/p\u003e\n\u003cp\u003e240 VAC @ 2.0 A resistive\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Current Rating (Resistive)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2.0 A steady state @ 5-30 VDC\u003c\/p\u003e\n\u003cp\u003e0.5 A steady state @ 48 VDC\u003c\/p\u003e\n\u003cp\u003e0.25 A steady state @ 125 VDC\u003c\/p\u003e\n\u003cp\u003e2.0 A steady state, 15 A make @ 125 VAC\u003c\/p\u003e\n\u003cp\u003e2.0 A steady state, 15 A make @ 240 VAC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Rating (Steady State)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e250 W max for 125 VAC resistive\u003c\/p\u003e\n\u003cp\u003e480 W max for 240 VAC resistive\u003c\/p\u003e\n\u003cp\u003e60 W max for 30 VDC resistive\u003c\/p\u003e\n\u003cp\u003e24 W max for 48 VDC resistive\u003c\/p\u003e\n\u003cp\u003e31 W max for 125 VDC resistive\u003c\/p\u003e\n\u003cp\u003e250 VA max for 125 VAC inductive\u003c\/p\u003e\n\u003cp\u003e480 VA max for 240 VAC inductive\u003c\/p\u003e\n\u003cp\u003e60 VA max for 30 VDC inductive\u003c\/p\u003e\n\u003cp\u003e24 VA max for 48 VDC inductive\u003c\/p\u003e\n\u003cp\u003e31 VA max for 125 VDC inductive\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Load Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 mA per point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInitial Contact Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 meg-Ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSwitching Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 operation per 3 seconds (0.3 Hz at rated load) maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBounce Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.2 ms (mean)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExpected Contact Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300K cycles resistive \/ 100K cycles inductive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Off-State Leakage Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 mA per point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Delay Time (OFF to ON \/ ON to OFF)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 ms maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConfigurable Fault \/ Program Mode States\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHold Last State, ON or OFF (OFF is default)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Power Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.5 W @ 60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThermal Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15.35 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 V maximum continuous; 100% tested at 2546 VDC for 1 second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Block\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTC-TBCH, 36-Position Terminal Block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUL Ratings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC300, R150 Pilot Duty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Slot Placement:\u003c\/strong\u003e The module occupies a single-wide slot within any position of an Experion Series-A chassis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Wiring:\u003c\/strong\u003e Connect field wiring directly using the TC-TBCH 36-pin terminal block or via pre-wired cable assembly connected to a Remote Terminal Panel (RTP).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFusing Protection:\u003c\/strong\u003e Outputs are not internally fused; use a fused RTP (e.g., Allen-Bradley 1492 interface system) to protect module output circuits against overcurrent conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemoval and Insertion Under Power (RIUP):\u003c\/strong\u003e Permitted in ordinary, non-hazardous locations. RIUP is strictly \u003cstrong\u003eNOT PERMITTED\u003c\/strong\u003e when installed in Class I, Division 2 hazardous locations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Requirements:\u003c\/strong\u003e Maintain compliance with ambient environment criteria (0 to 60 degC operative temperature limits) inside an industrial enclosure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL:\u003c\/strong\u003e UL 508 Industrial Control Equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Locations:\u003c\/strong\u003e Class I, Div 2, Groups A, B, C \u0026amp; D Hazardous and Ordinary locations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Directive:\u003c\/strong\u003e 89\/336\/EEC, EN 50081-2 Emissions, EN 50082-2 Immunity\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eC-Tick:\u003c\/strong\u003e Meets requirements of the Australian Radiocommunications Act of 1992\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667751235947,"sku":"TK-ORC161","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-tk-orc161-97180373-relay-output-module-3ybso3avw3w_8ae20af8-3b52-4842-8b9e-1bb495f2f192.jpg?v=1765501558"},{"product_id":"honeywell-sc-ucmx02-51307195-276-controledge-2020-non-redundant-controller","title":"Honeywell SC-UCMX02 51307195-276 ControlEdge 2020 Non Redundant Controller","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHoneywell SC-UCMX02 51307195-276\u003c\/strong\u003e is a modular, scalable process controller designed for remote automation and control applications. Powered by a dual-core ARM Cortex-A9 32-bit CPU running at 667 MHz, it provides integrated processing and direct field connections with 28 mixed onboard I\/O channels. The \u003cstrong\u003eSC-UCMX02\u003c\/strong\u003e non-redundant controller includes 256 MB DRAM, 256 MB Flash memory, and 4 Mbits of battery-free nonvolatile memory. Built-in serial and Ethernet communication ports support standard industrial protocols including Modbus, DNP3, HART-IP, IEC 60870-5-104, and MQTT\/Sparkplug. Designed for harsh remote operational environments, the unit operates in extended temperatures from -40 degC to 75 degC with conformal-coated assemblies and transient voltage suppression on all I\/O channels and serial\/Ethernet communication ports.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessor \u0026amp; Memory:\u003c\/strong\u003e Dual Core ARM Cortex-A9 (32-bit) 667 MHz processor with 256 MB DRAM, 256 MB Flash, and 4 Mbits nonvolatile memory requiring no battery backup.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOnboard Mixed I\/O:\u003c\/strong\u003e 28 integrated I\/O channels including 8 Analog Inputs (HART), 2 Analog Outputs (HART), 10 Digital Inputs, 6 Digital Outputs, and 2 Pulse\/Digital Inputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEthernet Communications:\u003c\/strong\u003e 2 ANSI\/IEEE 802.3 10\/100BaseTx RJ45 ports with 1500 V RMS isolation and transient voltage suppression.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSerial Interfaces:\u003c\/strong\u003e 2 RS232 ports (RJ45, full-duplex, up to 15m) and 2 RS485 ports (screw terminals, 2-wire half-duplex, up to 1200m).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocol Support:\u003c\/strong\u003e Supports Modbus RTU\/ASCII\/TCP, Enron Modbus, DNP3 TCP (Level 3+ Outstation\/Master), IEC60870-5-104, MQTT (Sparkplug B), and HART-IP.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExpandability:\u003c\/strong\u003e Supports up to 30 expansion I\/O modules across up to 5 expansion rows.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDatalogging:\u003c\/strong\u003e Event logs stored on internal Flash memory (up to 200,000 events) or an optional SD card (up to 500,000 events, up to 32GB Class 6\/10).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRuggedized Construction:\u003c\/strong\u003e Operates across -40 degC to 75 degC, compliant with ANSI\/ISA S71.04 Class G3 conformal coating and IEC 60068-2-6 vibration resistance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRemote Terminal Unit (RTU) process control\u003c\/li\u003e\n\u003cli\u003eOil and gas custody transfer and Electronic Flow Metering (EFM)\u003c\/li\u003e\n\u003cli\u003eWellhead control and artificial lift systems (Plunger Lift)\u003c\/li\u003e\n\u003cli\u003ePipeline monitoring and remote infrastructure automation\u003c\/li\u003e\n\u003cli\u003eRemote asset monitoring via HART-IP and field device integration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSC-UCMX02\u003c\/td\u003e\n\u003ctd\u003eNon-redundant Controller with 28 mixed onboard I\/O with 256MB DRAM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProcessor\u003c\/td\u003e\n\u003ctd\u003eDual Core ARM Cortex-A9 Core (32 bit) 667 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eDynamic Memory (RAM)\u003c\/td\u003e\n\u003ctd\u003e256 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eProgram Memory (Flash)\u003c\/td\u003e\n\u003ctd\u003e256 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eNonvolatile Memory\u003c\/td\u003e\n\u003ctd\u003e4 Mbits (20+ years data life, no battery required)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eReal-Time Clock Resolution\u003c\/td\u003e\n\u003ctd\u003e1 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eExecution Cycle Time\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;= 20 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e18 to 30 VDC (Rated 24 VDC +\/- 25%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eMaximum Input Current\u003c\/td\u003e\n\u003ctd\u003e1.20 A at 30 VDC (controller plus 9 IOMs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eMaximum Ripple Voltage\u003c\/td\u003e\n\u003ctd\u003e120 mVpp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eMin 1.7 W (no expansion IOMs) \/ Max 3.4 W (with expansion IOMs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOnboard I\/O - Analog Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e8 (Single ended, 4-20mA or 1-5VDC configurable, HART enabled)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eResolution \/ Accuracy\u003c\/td\u003e\n\u003ctd\u003e16-bit \/ +\/-0.1% at 25 degC (+\/-0.2% -40 degC to 75 degC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOnboard I\/O - Analog Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e2 (Source, 4-20mA, HART enabled)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eResolution \/ Accuracy\u003c\/td\u003e\n\u003ctd\u003e12-bit \/ +\/-0.2% at 25 degC (+\/-0.3% -40 degC to 75 degC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOnboard I\/O - Digital Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e10 (Sink \/ dry contact, 24VDC +\/-10% external supply)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eThresholds\u003c\/td\u003e\n\u003ctd\u003eGuaranteed ON \u0026gt;= 12 VDC, Guaranteed OFF \u0026lt;= 4 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOnboard I\/O - Digital Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e6 (Sink \/ voltage free, 24VDC, max 80 mA load per channel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eOn-State Voltage\u003c\/td\u003e\n\u003ctd\u003eMax 1 VDC at 80 mA max load current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOnboard I\/O - Pulse Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e2 (Sink, 0 to 10 kHz, 5 to 10 V peak to peak input)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication - Ethernet\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePorts \/ Speed\u003c\/td\u003e\n\u003ctd\u003e2 x RJ45 ports \/ 10\/100BaseTx auto-detecting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e1500 V RMS for 1 minute, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication - Serial\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS232 Ports\u003c\/td\u003e\n\u003ctd\u003e2 x RJ45 (TD, RD, CTS, RTS, CD, DTR, DSR\/RI, GND), full duplex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eRS485 Ports\u003c\/td\u003e\n\u003ctd\u003e2 x Screw terminals (GND, 485+, 485-, termination, chassis), 2-wire half-duplex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eBaud Rates\u003c\/td\u003e\n\u003ctd\u003e300 to 115200 bps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical \u0026amp; Environmental\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN rail (TH35-7.5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 degC to 75 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 degC to 85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eDimensions (L x W x H)\u003c\/td\u003e\n\u003ctd\u003e190 mm x 99 mm x 141 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e700 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Pin\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Terminals\u003c\/td\u003e\n\u003ctd\u003e18-30 VDC Power Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRS485 Port 1 \u0026amp; 2\u003c\/td\u003e\n\u003ctd\u003eScrew terminals: GND, 485+, 485-, Termination, Chassis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRS232 Port 1 \u0026amp; 2\u003c\/td\u003e\n\u003ctd\u003eRJ45: TD, RD, CTS, RTS, CD, DTR, DSR\/RI, GND\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Port 1 \u0026amp; 2\u003c\/td\u003e\n\u003ctd\u003eRJ45 shielded connectors (auto-crossover)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOnboard IOM\u003c\/td\u003e\n\u003ctd\u003e28-channel field terminal connections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSD Card Slot\u003c\/td\u003e\n\u003ctd\u003eSD Card interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Interface\u003c\/td\u003e\n\u003ctd\u003eExpansion I\/O Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Install on standard TH35-7.5 DIN rail in a vertical orientation to maintain natural thermal convection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e Connect an external 18 to 30 VDC power supply to the dedicated power terminals on the controller IOTA.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding \u0026amp; Shielding:\u003c\/strong\u003e Ensure all RJ45 Ethernet connectors use shielded cabling and connect chassis drain wires on RS485 terminal blocks to mitigate electrical noise.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransient Suppression:\u003c\/strong\u003e Built-in transient voltage suppression is present on all I\/O channels and communication interfaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExpansion Cabling:\u003c\/strong\u003e Connect expansion I\/O rows using standard CAT-5 cables routed between left and right end plates up to a maximum distance of 100 meters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Locations:\u003c\/strong\u003e CSA Class I, Division 2, Group A, B, C, D T4; Ex ec IIC T4 Gc; ATEX II 3 G Ex ec IIC T4 Gc; IECEx Ex ec IIC T4 Gc\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL Standards:\u003c\/strong\u003e UL121201, UL 60079-0, UL 60079-7, UL Std. No. 61010-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA Standards:\u003c\/strong\u003e CAN\/CSA-C22.2 No. 213-17, CAN\/CSA-C22.2 No. 61010-1-12, CAN\/CSA-C22.2 No. 60079-0:15, CAN\/CSA-C22.2 No. 60079-7:16, CAN\/CSA C22.2 No. 0-10\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX\/UKCA Standards:\u003c\/strong\u003e EN IEC60079-0:2018, EN 60079-7:2015+A1:2018\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC Standards:\u003c\/strong\u003e IEC 60079-0 (2017), IEC 60079-7:2017\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE Directives:\u003c\/strong\u003e LVD EN 61010-1 (2010), EMC EN 61326-1 (2013)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine Certification:\u003c\/strong\u003e Bureau Veritas (BV), DNV GL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSecurity Certification:\u003c\/strong\u003e ISASecure \/ IEC 62443 Conformance (Security Level 2)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental \u0026amp; Environmental Standards:\u003c\/strong\u003e UL 94 V-0 Flammability, ANSI\/ISA S71.04 Class G3 Conformal Coating, IEC 60068-2-6 Vibration\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667751596395,"sku":"SC-UCMX02 51307195-276","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-sc-ucmx02-51307195-276-power-supply-ot2jnjrlnqc_26f88d3e-c93d-4f67-8717-005f2d6f3ecf.jpg?v=1765501563"},{"product_id":"honeywell-fta-t-02-fail-safe-digital-output-fta-24-channel-24-48-60-vdc","title":"Honeywell FTA-T-02 Fail-Safe Digital Output FTA 24-Channel 24\/48\/60 VDC","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan\u003eFTA-T-02 (FTA-T-02)\u003c\/span\u003e by \u003cspan\u003eHoneywell\u003c\/span\u003e is a high-integrity \u003cspan\u003eFail-safe Digital Output Field Termination Assembly (FTA)\u003c\/span\u003e engineered for seamless integration with Safety Manager and FSC systems. This module serves as the critical interface between the safety controller and 24 field-side digital devices, supporting a versatile voltage range of \u003cspan\u003e24, 48, or 60 VDC\u003c\/span\u003e. Organized into \u003cspan\u003e24 independent channels\u003c\/span\u003e (split into 6 groups of 4), the \u003cspan\u003eFTA-T-02\u003c\/span\u003e is designed to maintain functional safety in high-risk environments such as \u003cspan\u003eoil refineries, gas processing plants, and chemical manufacturing\u003c\/span\u003e. Its fail-safe architecture ensures that in the event of a system fault, outputs transition to a predefined safe state, thereby protecting critical industrial assets and personnel from hazardous process excursions.\u003c\/p\u003e\n\u003ch3\u003eComprehensive Technical Parameter Matrix\u003c\/h3\u003e\n\u003cp\u003eThe following table provides the rigorous technical data required for engineering specifications and procurement alignment, adhering to Google E-E-A-T technical depth standards.\u003c\/p\u003e\n\u003ctable width=\"692\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cspan\u003eTechnical Parameter\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eSpecification Detail\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel Designation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFTA-T-02\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFail-safe Digital Output Field Termination Assembly\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eChannel Count\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 Channels (6 groups of 4)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVoltage Support\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 \/ 48 \/ 60 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMax Continuous Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 A per channel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMax Voltage (IEC 1010)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50 VDC (Category 3) \/ 150 VDC (Category 2)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMax Wire Diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.25 cm2 (AWG 14)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTerminal Torque\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 Nm (0.37 ft-lb)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRail Compatibility\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDIN EN TS32 \/ TS35 x 7.5\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions (L x W x H)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e14.5 cm x 7 cm x 5.7 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCertifications\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCE, UL\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOperations \u0026amp; Safety Integration FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eHow does the \"Fail-safe\" designation impact the operation of the FTA-T-02?\u003c\/span\u003eThe \u003cspan\u003eFTA-T-02\u003c\/span\u003e is built with diagnostic-ready circuitry that allows the host safety controller to monitor the health of the output loop. In the event of a detected internal failure or loss of communication, the module is designed to ensure the digital outputs revert to a \"de-energized\" or safe state, preventing unintended activation of field equipment.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWhat is the significance of the 6-group channel architecture?\u003c\/span\u003eBy dividing the \u003cspan\u003e24 channels\u003c\/span\u003e into \u003cspan\u003e6 groups of 4\u003c\/span\u003e, Honeywell provides localized circuit isolation. This allows for easier troubleshooting and ensures that a localized electrical fault within one group is less likely to propagate and impact the entire 24-channel array.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCan the FTA-T-02 handle higher voltages than 60 VDC?\u003c\/span\u003eAccording to \u003cspan\u003eIEC 1010\u003c\/span\u003e standards, the module can withstand up to \u003cspan\u003e150 VDC\u003c\/span\u003e under overvoltage category 2. However, for continuous, safe operation of the digital output logic, it is rated for nominal \u003cspan\u003e24\/48\/60 VDC\u003c\/span\u003e systems.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Deployment \u0026amp; Field Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTermination Protocol:\u003c\/span\u003e When wiring the screw terminals, ensure a strip length of exactly \u003cspan\u003e0.7 cm (0.28 in)\u003c\/span\u003e. Use a precision torque screwdriver to apply \u003cspan\u003e0.5 Nm\u003c\/span\u003e of force. Under-tightening can lead to resistive heating, while over-tightening may damage the AWG 14 lead or the terminal block housing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRail Spacing and Heat Management:\u003c\/span\u003e The \u003cspan\u003eFTA-T-02\u003c\/span\u003e requires a used rail length of \u003cspan\u003e14.6 cm\u003c\/span\u003e. In high-density cabinets, allow for adequate vertical spacing between the FTA and adjacent modules to facilitate natural convection, as the 2 A per channel load can generate significant heat during concurrent activation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eGrounding for EMC Compliance:\u003c\/span\u003e To maintain the \u003cspan\u003eCE and UL\u003c\/span\u003e certification integrity, ensure the DIN rail is bonded to a low-impedance earth ground. This provides a clear path for electrical transients and protects the fail-safe logic from electromagnetic interference (EMI) originating from nearby power switching equipment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplication Resilience \u0026amp; Technical Superiority\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan\u003eHoneywell FTA-T-02\u003c\/span\u003e stands as a benchmark for reliability in the Field Termination Assembly sector. Its robust physical construction (\u003cspan\u003e14.5 cm x 7 cm\u003c\/span\u003e) is optimized for the rigors of industrial control rooms where vibration and thermal fluctuations are constant variables. By utilizing high-quality screw terminals and gold-plated connector pins, the \u003cspan\u003eFTA-T-02\u003c\/span\u003e ensures long-term contact stability. As an \u003cspan\u003eOriginal and New\u003c\/span\u003e component, it offers full compatibility with legacy Safety Manager and FSC platforms, providing a high-availability solution for modernizing safety instrumented systems (SIS) without requiring extensive field-wiring re-engineering.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667751825771,"sku":"FTA-T-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-fta-t-02-fail-safe-digital-output-module-afgq1sfwuk5_07e51c7d-5b35-4f5b-83e6-76cd00ca3f1b.jpg?v=1765501568"},{"product_id":"honeywell-mc-pdoy22-80363975-150-series-c-digital-output-module","title":"Honeywell MC-PDOY22 80363975-150 Series C Digital Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell MC-PDOY22 (80363975-150) is a high-density digital output module designed specifically for integration within the Honeywell Experion PKS Series C I\/O architecture. This module provides reliable signal processing and control capabilities for industrial process automation systems, interfacing directly with actuators, solenoid valves, and indicator alarms.\u003c\/p\u003e\n\u003cp\u003eOperating as part of the Series C platform, the MC-PDOY22 supports streamlined cabinet layouts, modular marshalling, and DIN rail mounting to optimize space in control rooms. It facilitates secure command delivery from the controller to field devices, ensuring high availability and precise discrete output control in continuous process environments.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eEngineered for direct integration into the Honeywell Experion Series C I\/O infrastructure\u003c\/li\u003e\n  \u003cli\u003eHigh-density output configuration designed to minimize control cabinet footprint\u003c\/li\u003e\n  \u003cli\u003eDIN rail mounting compatibility for straightforward mechanical installation\u003c\/li\u003e\n  \u003cli\u003eRobust channel isolation providing protection against electrical noise and ground loops\u003c\/li\u003e\n  \u003cli\u003eStandardized Series C form factor supporting fast connection and removal under power (REM) where applicable\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOil and gas upstream and downstream processing facilities\u003c\/li\u003e\n  \u003cli\u003eChemical and petrochemical refining plants\u003c\/li\u003e\n  \u003cli\u003ePower generation and utility distribution systems\u003c\/li\u003e\n  \u003cli\u003eWater and wastewater treatment automation\u003c\/li\u003e\n  \u003cli\u003ePulp, paper, and heavy industrial manufacturing\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eGeneral Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eHoneywell\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Series\u003c\/td\u003e\n      \u003ctd\u003eExperion Series C\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModel \/ Part Number\u003c\/td\u003e\n      \u003ctd\u003eMC-PDOY22\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCatalog Number\u003c\/td\u003e\n      \u003ctd\u003e80363975-150\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModule Type\u003c\/td\u003e\n      \u003ctd\u003eDigital Output Module\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCountry of Origin\u003c\/td\u003e\n      \u003ctd\u003eUnited States\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNet Weight\u003c\/td\u003e\n      \u003ctd\u003e0.4 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDimensions\u003c\/td\u003e\n      \u003ctd\u003e7.0 cm x 14.0 cm x 14.5 cm\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eElectrical and I\/O Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMounting Type\u003c\/td\u003e\n      \u003ctd\u003eDIN Rail \/ Series C I\/O Carrier\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEnclosure Protection\u003c\/td\u003e\n      \u003ctd\u003eIP20\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eVerify that the part number MC-PDOY22 80363975-150 matches system design documentation.\u003c\/li\u003e\n  \u003cli\u003eEnsure all power to the target Series C I\/O slot is de-energized before handling hardware.\u003c\/li\u003e\n  \u003cli\u003eInspect the module and terminal blocks for any transit damage or bent pins.\u003c\/li\u003e\n  \u003cli\u003eSecurely mount the Series C I\/O carrier and snap the MC-PDOY22 module into its designated position.\u003c\/li\u003e\n  \u003cli\u003eConnect field wiring to the appropriate terminal blocks according to the system loop diagrams.\u003c\/li\u003e\n  \u003cli\u003eApply power and verify module health status through the Experion control station interface.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667752218987,"sku":"MC-PDOY22 80363975-150","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-mc-pdoy22-80363975-150-digital-output-module-2pdabvp4eun_791af043-c6eb-4105-a4bc-ddc4abb8a532.jpg?v=1765505274"},{"product_id":"honeywell-cc-paon01-51410070-176-series-c-non-hart-analog-output-module","title":"Honeywell CC-PAON01 51410070-176 Series C Non-HART Analog Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell CC-PAON01 51410070-176\u003c\/strong\u003e is a 16-channel non-HART Analog Output Module (AOM) designed for execution within the Experion PKS Series C I\/O architecture. Operating on an IOLINK managed by a C300 controller, the module receives digital control commands from the controller software and generates precise, analog 4-20mA current signals to drive field actuators, control valves, positioners, and variable speed drives.\u003c\/p\u003e\n\u003cp\u003eEngineered as a core component of the Experion PKS automation platform, the \u003cstrong\u003eHoneywell CC-PAON01 51410070-176\u003c\/strong\u003e occupies a dedicated slot on a compatible Input Output Termination Assembly (IOTA). It utilizes an IOM block designation of AO. The module features a vertical, tilted form factor optimized for cabinet heat dissipation, toolless field replacement, and seamless integration with single or redundant IOTA configurations.\u003c\/p\u003e\n\u003cp\u003eCompared to earlier analog output variants such as the CC-PAOX01, the \u003cstrong\u003eHoneywell CC-PAON01 51410070-176\u003c\/strong\u003e represents an updated hardware baseline designed for non-HART loop control. In redundant implementations, paired modules share the control load and provide auto-failover, ensuring continuous output generation for critical process loops.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFeatures 16 independent analog output channels designed for standard non-HART 4-20mA process control loops.\u003c\/li\u003e\n\u003cli\u003eUses the standardized AO IOM function block within Experion PKS Control Builder software.\u003c\/li\u003e\n\u003cli\u003eConnects directly to Experion C300 controllers over redundant IOLINK communications networks.\u003c\/li\u003e\n\u003cli\u003eCompatible with both non-redundant (CC-TAON01) and redundant (CC-TAON11) Series C I\/O Termination Assemblies.\u003c\/li\u003e\n\u003cli\u003eFast startup cycle capable of initializing in approximately 10 seconds following module-level power restoration.\u003c\/li\u003e\n\u003cli\u003eSupports high-density cabinet mounting with Series C vertical inclination for efficient thermal management.\u003c\/li\u003e\n\u003cli\u003eOn-board diagnostic reporting continuously updates module status and hardware health to the Experion system.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFinal Control Element Driving:\u003c\/strong\u003e Delivers 4-20mA analog current signals to control valves, I\/P converters, and electronic valve positioners.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpeed Reference Signals:\u003c\/strong\u003e Sends continuous setpoint control signals to Variable Frequency Drives (VFDs) and motor control centers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Process Control Loops:\u003c\/strong\u003e Serves as the primary analog output interface for pressure, flow, temperature, and level regulation across process industries.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDCS Upgrades and Expansions:\u003c\/strong\u003e Serves as the updated Series C module model for expanding or replacing legacy non-HART analog output channels.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003eCC-PAON01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e51410070-176\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eSeries C Analog Output Module (Non-HART)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eExperion PKS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eController Interface\u003c\/td\u003e\n\u003ctd\u003eC300 Controller via IOLINK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Capacity\u003c\/td\u003e\n\u003ctd\u003e16 Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal Range\u003c\/td\u003e\n\u003ctd\u003e4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHART Communication\u003c\/td\u003e\n\u003ctd\u003eNot Supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIOM Block Name\u003c\/td\u003e\n\u003ctd\u003eAO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquivalent PM I\/O IOP Type\u003c\/td\u003e\n\u003ctd\u003eAO16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Non-Redundant IOTA\u003c\/td\u003e\n\u003ctd\u003eCC-TAON01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Redundant IOTA\u003c\/td\u003e\n\u003ctd\u003eCC-TAON11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Initialization Time\u003c\/td\u003e\n\u003ctd\u003e10 seconds (±25%) post module power loss\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet Level Recovery Time\u003c\/td\u003e\n\u003ctd\u003e60 seconds (±25%) post cabinet power loss\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eInterface \/ Assembly\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane\/IOTA Connector\u003c\/td\u003e\n\u003ctd\u003eConnects the module to the IOTA board for internal 24V DC power and dual IOLINK communications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC-TAON01 Terminal Block\u003c\/td\u003e\n\u003ctd\u003eInterface for 16 non-redundant field output loops\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC-TAON11 Terminal Block\u003c\/td\u003e\n\u003ctd\u003eDual-module interface providing redundant 16-channel field output connections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel \u0026amp; Compatibility Check:\u003c\/strong\u003e Verify that the physical module part number (CC-PAON01 \/ 51410070-176) matches system design and that the destination IOTA is model CC-TAON01 (non-redundant) or CC-TAON11 (redundant).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower \u0026amp; Safety:\u003c\/strong\u003e Ensure cabinet power distribution conforms to Honeywell Series C installation requirements. Keep the ESD grounding strap attached while handling the module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Mounting:\u003c\/strong\u003e Align the module guide pins with the dedicated slot on the IOTA board. Press firmly until the module latches securely into place.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Verification:\u003c\/strong\u003e Confirm that field loop wiring is properly connected to the screw terminals or field wiring connectors on the IOTA board prior to energizing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Initialization:\u003c\/strong\u003e Apply system power. The module will complete its internal diagnostic self-test and initialize within approximately 10 seconds.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eConfiguration \u0026amp; Replacement Recommendations\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSoftware Configuration:\u003c\/strong\u003e In Experion Control Builder, assign the module using the AO IOM function block. Ensure the corresponding IOLINK block is configured for Series C I\/O communication.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLegacy Model Migration:\u003c\/strong\u003e Note that CC-PAON01 is the designated updated model for the older CC-PAOX01 analog output module. Because CC-PAON01 and CC-PAOX01 cannot be mixed within a redundant pair, both modules in a redundant configuration must be updated simultaneously.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundant Module Replacement:\u003c\/strong\u003e When replacing one module of an active redundant pair, verify that the active module is healthy. Insert the replacement module into the secondary slot on the CC-TAON11 IOTA. The controller will sync firmware and parameters to the new module automatically.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667752677739,"sku":"CC-PAON01 51410070-176","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-cc-paon01-51410070-176-analog-output-module-tzbo4c1tlzd_55ed9c8b-7d02-47fa-9f85-481a243645f1.jpg?v=1765501582"},{"product_id":"honeywell-mu-tdor22-51309150-125-digital-output-relay-field-termination-assembly","title":"Honeywell MU-TDOR22 51309150-125 Digital Output Relay Field Termination Assembly","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell MU-TDOR22\u003c\/strong\u003e (Assembly No. \u003cstrong\u003e51309150-125\u003c\/strong\u003e) is a 16-point 240 VAC Digital Output Relay Field Termination Assembly (FTA) designed for integration within Honeywell TotalPlant Solution (TPS), Process Manager (PM), Advanced Process Manager (APM), High Performance Process Manager (HPM), and Enhanced High Performance Process Manager (EHPM) DCS architectures. Acting as a critical interface between digital output processors (IOPs) and field-level actuators, the module provides galvanically isolated relay contacts engineered for switching high-voltage AC and DC loads.\u003c\/p\u003e\n\u003cp\u003eThe core architecture of the \u003cstrong\u003eMU-TDOR22\u003c\/strong\u003e features electromagnetic or solid-state relay output channels that provide physical isolation between the low-voltage internal system logic and field equipment. This configuration protects control system electronics from electrical noise, voltage transients, and field-side fault conditions. The assembly interfaces with standard Honeywell 32-point or 16-point Digital Output IOPs via standard system interface cables up to 50 meters in length, decoding system output commands into dry contact closures or powered switching outputs for heavy-duty industrial devices.\u003c\/p\u003e\n\u003cp\u003eDesigned for demanding process environments, the \u003cstrong\u003eMU-TDOR22\u003c\/strong\u003e assembly (51309150-125) handles direct control of high-power final control elements, including motor starters, solenoids, indicator panels, alarm horns, and interlock circuits. The card-mounted terminal blocks accommodate robust field wiring, while on-board fusing and suppression networks shield field wiring circuits from inductive kickback and current overloads.\u003c\/p\u003e\n\u003cp\u003eWhen installed within standard TPS cabinets, the board operates seamlessly across redundant or non-redundant I\/O configurations, maintaining deterministic update execution independently of controller processing overhead. Its rugged layout, high dielectric isolation rating, and compatibility with standard Honeywell Standby Manual units ensure operational continuity and high system availability during online maintenance or module replacements.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Voltage Relay Interface:\u003c\/strong\u003e Provides 16 discrete relay channels tailored for 240 VAC high-power switching applications in DCS environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGalvanic Isolation:\u003c\/strong\u003e Offers robust optical and mechanical isolation between field circuits and internal controller logic to prevent ground loops and protect system electronics.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Contact Load Handling:\u003c\/strong\u003e Accommodates high-current AC and DC field loads, ideal for direct driving of motor contactors, solenoids, and heavy-duty actuators.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Circuit Protection:\u003c\/strong\u003e Includes individual channel fusing and contact suppression networks to handle inductive load transients and short circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem-Wide IOP Compatibility:\u003c\/strong\u003e Fully compatible with Honeywell PM, APM, HPM, and EHPM Digital Output Processors across standard 50-meter cable runs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandby Manual Support:\u003c\/strong\u003e Supports connection to external Standby Manual units to allow manual output overrides and seamless maintenance without dropping field loads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConformal Coating Option:\u003c\/strong\u003e Available with environmental hardening options for installation in ISA G3 severe corrosive industrial atmospheres.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Terminal Design:\u003c\/strong\u003e Features heavy-duty compression or screw terminal options accepting up to 14 AWG field wiring for simplified installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFinal Control Element Switching:\u003c\/strong\u003e Direct pilot control of 120\/240 VAC motor starters, contactors, and variable speed drive run\/stop permissive loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSolenoid Valve Control:\u003c\/strong\u003e High-reliability actuation of heavy-duty pneumatic and hydraulic solenoid valves across oil, gas, and chemical process units.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlarm \u0026amp; Annunciator Interfacing:\u003c\/strong\u003e Driving high-power field sirens, visual beacons, indicator light panels, and master safety interlock relays.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDCS Isolation \u0026amp; Expansion:\u003c\/strong\u003e Providing clean dry-contact interface signals between Honeywell TPS automation networks and third-party packaged equipment or PLCs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003eMU-TDOR22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart \/ Assembly Number\u003c\/td\u003e\n\u003ctd\u003e51309150-125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Output Relay Field Termination Assembly (FTA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eHoneywell TPS (PM, APM, HPM, EHPM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e16 discrete channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Field Voltage\u003c\/td\u003e\n\u003ctd\u003e240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField-to-System Isolation\u003c\/td\u003e\n\u003ctd\u003e1500 V rms or ±1500 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Technique\u003c\/td\u003e\n\u003ctd\u003eGalvanic \/ Optical Isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterfacing Cable Distance\u003c\/td\u003e\n\u003ctd\u003eUp to 50 meters to Digital Output IOP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Wire Size\u003c\/td\u003e\n\u003ctd\u003eUp to 14 AWG (~1.6 mm) compression \/ screw terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 50 degC (cabinet ambient)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003e10 to 90% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Environment\u003c\/td\u003e\n\u003ctd\u003eISA G1 (Mild) \/ ISA G3 (Harsh option available)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eInterface \/ Connector\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIOP Cable Connector\u003c\/td\u003e\n\u003ctd\u003eAccepts standard Honeywell multi-conductor cable for direct connection to Digital Output IOP (up to 50 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Terminal Blocks\u003c\/td\u003e\n\u003ctd\u003eHeavy-duty compression or screw terminals for direct 16-channel field wiring and relay load connections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandby Manual Connector\u003c\/td\u003e\n\u003ctd\u003eInterface port for connecting optional Honeywell Standby Manual Override Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003ePre-Installation Inspection:\u003c\/strong\u003e Verify the board part number (MU-TDOR22 \/ 51309150-125) and check for any physical damage prior to mounting inside the cabinet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Securely latch the Field Termination Assembly into the standard FTA mounting channel within the Honeywell cabinet or enclosure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Interruption:\u003c\/strong\u003e Ensure field-side load power and cabinet power are disconnected before attaching wiring to prevent electrical shock or arc flash hazards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Verification:\u003c\/strong\u003e Strip field conductors appropriately and connect 240 VAC load circuits to the corresponding channel terminals using up to 14 AWG wire, verifying tight mechanical connections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIOP Cable Connection:\u003c\/strong\u003e Connect the pre-fabricated Honeywell I\/O cable between the FTA board connector and the assigned Digital Output Processor slot in the cardfile.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Verify that cabinet protective earthing and shielding grounds are continuously bonded according to Honeywell system installation guidelines.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommissioning Checks:\u003c\/strong\u003e Perform point-to-point wiring continuity checks, verify fuse integrity, and apply load power prior to bringing the associated IOP online.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667753136491,"sku":"MU-TDOR22 51309150-125","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/s-l1600_1200x1200_ca6723cc-cded-48bb-b2f0-41cb5db3ddfd.webp?v=1787713068"},{"product_id":"honeywell-k4lcn-16-51403519-160-lcn-node-processor-board","title":"Honeywell K4LCN-16 51403519-160 LCN Node Processor Board","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell K4LCN-16 51403519-160\u003c\/strong\u003e is a Local Control Network (LCN) node processor board designed for high-performance computing within Honeywell TotalPlant Solution (TPS) and TDC 3000X system environments. It functions as the central LCN node processor kernel, executing core control system software, managing Local Control Network point data, and providing the processing baseline required for advanced process control and Application ModuleX (AXM) coprocessor integration.\u003c\/p\u003e\n\u003cp\u003eFeaturing a 68040 microprocessor with integrated floating-point calculation hardware, the \u003cstrong\u003eHoneywell K4LCN-16 51403519-160\u003c\/strong\u003e provides on-board processing speed and execution capacity for complex control algorithms, custom data segments, and Control Language (CL) applications. The board is equipped with 16 megawords of memory via a horizontally pluggable DIMM-style mezzanine board assembly (51402755-100), fulfilling the expanded memory requirements needed for TPS Software Release 500 and later.\u003c\/p\u003e\n\u003cp\u003eOperating in five-slot chassis configurations, the \u003cstrong\u003eHoneywell K4LCN-16 51403519-160\u003c\/strong\u003e interfaces directly with the LCN backplane through an associated CLCN A\/B I\/O or LCN I\/O board. In Application ModuleX architectures, it operates alongside an HP-UX-based coprocessor (WSI2 assembly) to bridge high-level UNIX process control solutions with low-level TDC 3000 real-time plant data structures.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDriven by a 68040 processor with dedicated floating-point calculation hardware capability for high-speed control execution.\u003c\/li\u003e\n\u003cli\u003eEquipped with 16 megawords of on-board memory utilizing a Dual In-line Memory Module (DIMM) style mezzanine card.\u003c\/li\u003e\n\u003cli\u003eServes as the LCN node processor kernel supporting TotalPlant Solution (TPS) system software Release 500 and later.\u003c\/li\u003e\n\u003cli\u003eDirect integration capability with HP-UX coprocessors (WSI2 boards) in Application ModuleX (AXM) node architectures.\u003c\/li\u003e\n\u003cli\u003eComprehensive front-edge visual diagnostic status array, including a 3-digit alphanumeric Node Address\/Error Display.\u003c\/li\u003e\n\u003cli\u003eOn-board Error Detection and Correction (EDAC) with LED indication for single-bit and multi-bit RAM errors.\u003c\/li\u003e\n\u003cli\u003eIntegrated diagnostic tracking for DTAK timeout, BGAK timeout, bus parity errors, data compare errors, and LCN transaction failures.\u003c\/li\u003e\n\u003cli\u003eBackplane compatibility with CLCN A\/B I\/O and standard LCN I\/O cards for dual-redundant coaxial LCN cable connections.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotalPlant Solution (TPS) LCN Nodes:\u003c\/strong\u003e Functions as the primary processing engine for LCN-based system nodes requiring high-speed floating-point computations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication ModuleX (AXM) Execution:\u003c\/strong\u003e Executes real-time Control Language (CL) routines, maintains LCN point databases, and interfaces directly with HP-UX coprocessor solutions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLegacy TDC 3000X Upgrades:\u003c\/strong\u003e Provides memory expansion to 16 megawords required when upgrading system software to Release 500 or higher.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlant Information Network (PIN) Data Gateway:\u003c\/strong\u003e Serves as the real-time control link bridging LCN process data with higher-level plant information networks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e51403519-160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Identifier\u003c\/td\u003e\n\u003ctd\u003eK4LCN-16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor Architecture\u003c\/td\u003e\n\u003ctd\u003eMotorola 68040 with integrated floating-point unit (FPU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Capacity\u003c\/td\u003e\n\u003ctd\u003e16 Megawords\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Board Style\u003c\/td\u003e\n\u003ctd\u003eDIMM-style mezzanine board (Assembly 51402755-100)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSoftware Compatibility\u003c\/td\u003e\n\u003ctd\u003eTotalPlant Solution (TPS) R500 and later\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardware Chassis Compatibility\u003c\/td\u003e\n\u003ctd\u003e5-Slot LCN Chassis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNode Address Display\u003c\/td\u003e\n\u003ctd\u003e3-digit alphanumeric LED display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostic Status LEDs (Red)\u003c\/td\u003e\n\u003ctd\u003eRST\/PWR Fail, Self-Test Error, Data Compare Error, DTAK Time Out, BGAK Time Out, Data Parity Error, Bus Error, EDAC Single-Bit Error, EDAC Multi-Bit Error, LCN Transaction Error\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostic Status LEDs (Green)\u003c\/td\u003e\n\u003ctd\u003eSelf-Test Pass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostic Status LEDs (Yellow)\u003c\/td\u003e\n\u003ctd\u003eTX (LCN Transmit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Redundancy Support\u003c\/td\u003e\n\u003ctd\u003eDual LCN coaxial connections via CLCN A\/B I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eInterface \/ Component\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Edge Connector\u003c\/td\u003e\n\u003ctd\u003eModule bus interface for power, data, and system bus communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMezzanine Memory Connector\u003c\/td\u003e\n\u003ctd\u003eInterface for 16 Megaword DIMM memory board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTS1 \/ TS2 Pinning Block\u003c\/td\u003e\n\u003ctd\u003eOn-board LCN address pinning (Must have all jumpers removed when used with CLCN A\/B I\/O or LCN I\/O board)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003ePre-Installation Inspection:\u003c\/strong\u003e Verify the physical integrity of the circuit board, edge connectors, and the mounted 16 Megaword memory mezzanine card (51402755-100).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAddress Pinning Verification:\u003c\/strong\u003e Ensure all LCN address jumpers on the K4LCN-16 board (TS1\/TS2 block) are completely removed when installing behind a CLCN A\/B I\/O or LCN I\/O card. Pinning must be set exclusively on the rear I\/O board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Preparation:\u003c\/strong\u003e Confirm system power is switched OFF at the node power supply. Electrostatic Discharge (ESD) protective grounding must be used during handling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBoard Mounting:\u003c\/strong\u003e Slide the board into Slot 1 of the 5-slot LCN chassis until the backplane connectors seat firmly. Secure the board using the top and bottom extraction\/insertion levers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Cabling Check:\u003c\/strong\u003e Confirm that LCN Coax A and Coax B network cables are securely attached to the corresponding CLCN A\/B rear I\/O card.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eReplacement Recommendations\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSoftware Shutdown:\u003c\/strong\u003e Before removing power, execute an orderly node processor software shutdown via the LCN AM Status display. Perform a second shutdown command to force the node into a failed state, preventing surrounding LCN nodes from marking it isolated.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Down Sequence:\u003c\/strong\u003e Turn off the chassis power supply only after confirming that dependent coprocessor systems (such as the WSI2 board yellow LED) have completely shut down.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMemory Board Handling:\u003c\/strong\u003e Replacement K4LCN boards ordered from spare parts may arrive without the memory mezzanine board. Transfer or install a dedicated 16 Megaword board prior to insertion.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePost-Replacement Commissioning:\u003c\/strong\u003e Apply power and observe the front panel LEDs. Ensure the green \"Self-Test Pass\" LED illuminates and the 3-digit display correctly reflects the node address assigned on the rear LCN I\/O board.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667754938731,"sku":"K4LCN-16 51403519-160","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-k4lcn-16-51403519-160-control-board-bdewkwo0fya_ff9df4ad-ee56-4ef3-bd5c-82c2ab988de8.jpg?v=1765501620"},{"product_id":"honeywell-8c-pain01-51454356-175-series-8-coated-high-level-analog-input-module","title":"Honeywell 8C-PAIN01 51454356-175 Series 8 Coated High-Level Analog Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell 8C-PAIN01\u003c\/strong\u003e (Part Number \u003cstrong\u003e51454356-175\u003c\/strong\u003e) is a conformally coated, 16-channel High-Level Analog Input Module (IOM) designed for high-density analog signal processing within the Honeywell Experion Process Knowledge System (PKS) and PlantCruise by Experion Series 8 I\/O architecture. Operating under the control of the C300 Controller, the module interfaces directly with 4-20 mA DC current signals from 2-wire field transmitters or self-powered process instruments.\u003c\/p\u003e\n\u003cp\u003eArchitecturally, the \u003cstrong\u003eHoneywell 8C-PAIN01\u003c\/strong\u003e mounts directly onto a Series 8 Input Output Termination Assembly (IOTA) via physical blind-mating connectors, completely eliminating the need for a separate electronic chassis or external marshalling racks. Its physical form factor features the signature Series 8 tilted housing layout, which optimizes thermal dissipation performance and allows high cabinet packing density without compromise to system availability.\u003c\/p\u003e\n\u003cp\u003eEngineered with conformal coating (designated by the 8C prefix), the \u003cstrong\u003eHoneywell 8C-PAIN01\u003c\/strong\u003e internal circuitry is protected against atmospheric moisture, conductive dust, airborne chemical contaminants, and temperature extremes. The module includes integrated, individually protected current-limiting power distribution to feed field transmitters directly from the IOTA. This built-in signal conditioning provides Class 1, Division 2 non-incendive field power without requiring external user-supplied field power supplies or inline field fuses.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e16 Single-Ended Input Channels:\u003c\/strong\u003e Accepts standard 4-20 mA analog signals across a 200 ohm sense resistor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e16-Bit A\/D Resolution:\u003c\/strong\u003e High-resolution analog-to-digital conversion provides precise input sampling for process control variables.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFast Loop Execution:\u003c\/strong\u003e Features a 50 ms input scan rate across all channels for rapid process variable updates to the C300 controller.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConformally Coated Assembly:\u003c\/strong\u003e Provides physical circuit board protection against harsh environmental contaminants, humidity, and chemical exposure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-Incendive Transmitter Power:\u003c\/strong\u003e Delivers integrated, current-limited transmitter field power supporting Class 1, Div 2 hazardous locations without external marshalling or fuses.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundant \u0026amp; Non-Redundant Configurations:\u003c\/strong\u003e Plugs onto the 6-inch non-redundant IOTA (8C-TAIX51) or the 12-inch redundant IOTA (8C-TAIX61) where dual IOMs reside on a single assembly without external switchover cabling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Heat Management:\u003c\/strong\u003e Tilted vertical module design promotes cabinet air circulation and heat dissipation in high-density installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcess Variable Monitoring:\u003c\/strong\u003e Continuous current loop measurement from pressure, flow, level, and temperature transmitters in continuous or batch process environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDCS Control Loop Inputs:\u003c\/strong\u003e Direct process variable (PV) feedback to the C300 Controller for PID control strategies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area Field Interfacing:\u003c\/strong\u003e Powering and acquiring 4-20 mA current loops in Class 1, Division 2 process plant environments using non-incendive circuit topology.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e8C-PAIN01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e51454356-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries \/ Platform\u003c\/td\u003e\n\u003ctd\u003eSeries 8 I\/O \/ PlantCruise by Experion \/ Experion PKS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eHigh-Level Analog Input Module (Coated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e16 Channels (Single-Ended)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Type\u003c\/td\u003e\n\u003ctd\u003e4-20 mA DC (2-wire or self-powered transmitters)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA\/D Converter Resolution\u003c\/td\u003e\n\u003ctd\u003e16 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Resistance \/ Range\u003c\/td\u003e\n\u003ctd\u003e4-20 mA through 200 ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Scan Rate\u003c\/td\u003e\n\u003ctd\u003e50 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardware Accuracy (@ CMV = 0 V)\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e+\/-0.075% of full-scale (23.5 degC +\/- 2 degC)\u003c\/p\u003e\n\u003cp\u003e+\/-0.15% of full-scale (0 to 60 degC)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Non-Damaging Input Voltage\u003c\/td\u003e\n\u003ctd\u003e+\/-30 VDC (any input referenced to common)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNormal Mode Rejection Ratio (NMRR)\u003c\/td\u003e\n\u003ctd\u003e19 dB at 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNormal Mode Filter Response\u003c\/td\u003e\n\u003ctd\u003eSingle-pole RC, -3 dB @ 6.5 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel-to-Channel Crosstalk\u003c\/td\u003e\n\u003ctd\u003e-60 dB (DC to 60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Power Conditioning\u003c\/td\u003e\n\u003ctd\u003eIndividually protected current-limiting circuits (Class 1, Div 2 non-incendive)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Non-Redundant IOTA\u003c\/td\u003e\n\u003ctd\u003e8C-TAIX51 (Coated, 6-inch \/ 152 mm width)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Redundant IOTA\u003c\/td\u003e\n\u003ctd\u003e8C-TAIX61 (Coated, 12-inch \/ 304 mm width)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Verification:\u003c\/strong\u003e Confirm that the mounting environment matches the module specifications. Though the \u003cstrong\u003eHoneywell 8C-PAIN01\u003c\/strong\u003e features conformal coating, cabinet temperature should remain within 0 to 60 degC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIOTA Installation:\u003c\/strong\u003e Mount the compatible IOTA assembly (8C-TAIX51 for single, 8C-TAIX61 for redundant configurations) to the cabinet mounting channel. Securely fasten the bushed 24 VDC power connections to the backplane carrier.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Wiring Termination:\u003c\/strong\u003e Land field instrument wiring at the two-level detachable screw terminals on the IOTA. Ensure signal polarity matches 2-wire powered or self-powered loop configurations (wiring accepts up to 12 AWG \/ 2.5 mm2 stranded wire).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Insertion:\u003c\/strong\u003e Align the rear connector pins of the \u003cstrong\u003e8C-PAIN01\u003c\/strong\u003e module with the dedicated IOM slot on the IOTA. Press firmly until the mechanical latches seat completely.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundant Assembly Setup:\u003c\/strong\u003e If configuring redundant analog inputs on an 8C-TAIX61 IOTA, insert two identical \u003cstrong\u003e8C-PAIN01\u003c\/strong\u003e modules into the primary and secondary slots. Redundancy control is handled directly by the IOTA hardware backplane without external interconnect cables.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eConfiguration Recommendations\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Assignment:\u003c\/strong\u003e Assign the \u003cstrong\u003e8C-PAIN01\u003c\/strong\u003e module to its designated I\/O Link channel under the host C300 Controller configuration tree in the engineering environment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel Parameterization:\u003c\/strong\u003e Define the input signal range, PV scaling limits, filter constant, and failure state handling for each of the 16 analog channels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Budgeting Check:\u003c\/strong\u003e Verify total current consumption from 2-wire field loops to ensure the IOTA 24 VDC supply bus remains well within operational margins during normal field instrument draw.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommissioning \u0026amp; Diagnostic Verification:\u003c\/strong\u003e Prior to placing loops into auto control, inspect the Series 8 status indicator on the module front panel to confirm green operational health and verify individual process values at the engineering station.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667755397483,"sku":"8C-PAIN01 51454356-175","price":1800.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/8C-PAIN01-51454356-175_001_1200x1200_6ea21ba4-56a0-45b7-a951-3307a52b0c70.jpg?v=1786802593"},{"product_id":"honeywell-fc-iochas-0001s-safety-manager-i-o-chassis","title":"Honeywell FC-IOCHAS-0001S Safety Manager I\/O Chassis","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell FC-IOCHAS-0001S\u003c\/strong\u003e is a single I\/O chassis designed for process safety, emergency shutdown (ESD), and critical control applications in industrial environments. Constructed to accommodate Safety Manager I\/O modules and associated bus components, the assembly features a 19-inch rack-mountable form factor with integrated backplane interconnects, key coding positions, and power distribution interfaces for process automation architectures.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for single Safety Manager controller configurations requiring dedicated I\/O expansion.\u003c\/li\u003e\n\u003cli\u003eEquipped with backplane connectors featuring SOURIAU 5159 mechanical key coding pin positions to prevent module misplacement.\u003c\/li\u003e\n\u003cli\u003eProvides integrated bus printed circuit board (PCB) routing for internal 5 Vdc logic power distribution and watchdog signals.\u003c\/li\u003e\n\u003cli\u003eIncorporates card connector slots for standard input, output, and special-function modules.\u003c\/li\u003e\n\u003cli\u003eFeatures robust mechanical mounting design compatible with standard 19-inch cabinet frames and swing frame structures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSafety Instrumented Systems (SIS)\u003c\/li\u003e\n\u003cli\u003eEmergency Shutdown Systems (ESD)\u003c\/li\u003e\n\u003cli\u003eFire and Gas Detection Systems (F\u0026amp;G)\u003c\/li\u003e\n\u003cli\u003eBurner Management Systems (BMS) and Boiler Protection\u003c\/li\u003e\n\u003cli\u003eCritical Process Control in Chemical, Petrochemical, and Energy Plants\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFC-IOCHAS-0001S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSafety Manager I\/O Chassis (Single)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSub-assembly \/ Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIOCHAS-0001S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConformal Coated (FC Prefix)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5 degC to 70 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 degC to 85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5% to 95% (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSinusoidal Vibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 to 57 Hz: 0.075 mm amplitude; 57 to 150 Hz: 1 G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical Shock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 G peak acceleration (11 ms pulse duration, 3 axes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24 Vdc Supply Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 Vdc (+30% \/ -15%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKey Coding System\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSOURIAU type 5159 (pins 5159.009.17.22)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIngress Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP 20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCabinet Mount:\u003c\/strong\u003e Install the chassis securely inside a standard cabinet or 180-degree swing frame using appropriate captive nuts and mounting hardware.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Keying:\u003c\/strong\u003e Ensure that all backplane chassis pin positions are properly populated with SOURIAU 5159 coding pins matching the intended I\/O module type prior to card insertion.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower \u0026amp; Logic Connections:\u003c\/strong\u003e Verify proper termination of the 5 Vdc supply line, 24 Vdc power bus, and watchdog signal lines via dedicated distribution boards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Connect the chassis frame directly to the cabinet safety earth bar using approved earthing straps.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVentilation:\u003c\/strong\u003e Maintain unobstructed vertical airflow across all installed card slots to ensure operation within specified thermal limits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 61508 \/ IEC 61511:\u003c\/strong\u003e Functional safety up to SIL 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 61010-1 \/ IEC 61131-2:\u003c\/strong\u003e Safety requirements and equipment specifications for programmable controllers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 61000-6-2 \/ IEC 61326-3-1:\u003c\/strong\u003e Immunity for industrial and safety-related systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 508 \/ UL 508A:\u003c\/strong\u003e Standard for Industrial Control Equipment \/ Industrial Control Panels\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 142:\u003c\/strong\u003e Process Control Equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFM3600 \/ FM 3611:\u003c\/strong\u003e Class I, Division 2, Groups A, B, C \u0026amp; D hazardous location compliance\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667756904811,"sku":"FC-IOCHAS-0001S","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/FS-IOCHAS-0001S_001_1200x1200_e5fbcd8d-9a34-40c5-b657-362718070cbf.jpg?v=1786425574"},{"product_id":"honeywell-mc-tlpa02-51309204-175-high-performance-process-manager-power-adapter","title":"Honeywell MC-TLPA02 51309204-175 High-Performance Process Manager Power Adapter","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell MC-TLPA02\u003c\/strong\u003e (Part Number \u003cstrong\u003e51309204-175\u003c\/strong\u003e) is a conformally coated Power Adapter designed for High-Performance Process Manager (HPM) subsystem architectures within Honeywell TotalPlant Solution (TPS) and TDC 3000 systems. Operating on the Universal Control Network (UCN) and Local Control Network (LCN) platforms, it provides interface and power management for high-density analog multiplexers and serial communications field termination assemblies (FTAs).\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell MC-TLPA02\u003c\/strong\u003e (Part Number \u003cstrong\u003e51309204-175\u003c\/strong\u003e) integrates specialized field termination assemblies—such as Low Level Analog Input Multiplexers (LLMux), Remote Hardened Low Level Multiplexers (RHMUX), and Serial Interface \/ Serial Device Interface units—with their respective Input\/Output Processors (IOPs) in the HPM card file. The adapter manages power conditioning and signal interface distribution, enabling sequential multiplexing of low-level analog inputs (such as thermocouples and RTDs) or serial protocol conversions for third-party device integration.\u003c\/p\u003e\n\u003cp\u003eFeaturing conformal coating, the \u003cstrong\u003eHoneywell MC-TLPA02\u003c\/strong\u003e is engineered to withstand harsh environment classifications defined by ANSI\/ISA-S71.04-1985, protecting sensitive electronic components against airborne contaminants, humidity, and chemical corrosion.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSubsystem Integration:\u003c\/strong\u003e Interconnects specialized field termination assemblies (LLMux, RHMUX, SDI, SI) to HPM Input\/Output Processors (IOPs).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConformal Coating Protection:\u003c\/strong\u003e Designed to withstand airborne contaminants and harsh environmental conditions according to ANSI\/ISA-S71.04 specifications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow-Level Multiplexing Support:\u003c\/strong\u003e Facilitates power and signal routing for sequential multiplexing of Thermocouples (TC) and Resistance Temperature Detectors (RTDs).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSerial Interface Management:\u003c\/strong\u003e Supplies necessary interface power for EIA-232 and EIA-422\/485 serial communication FTAs, enabling connections to Modbus, Allen-Bradley, and proprietary devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCabinet Flexibility:\u003c\/strong\u003e Supports installation within 7-slot and 15-slot HPM card file layouts across single-access or dual-access cabinet configurations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow Level Temperature Multiplexing:\u003c\/strong\u003e Interfaces multi-channel thermocouple and RTD signal conditioning FTAs to LLAI\/LLMux Input\/Output Processors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote Hardened I\/O Processing:\u003c\/strong\u003e Connects RHMUX field assemblies installed in harsh or hazardous industrial locations to control room card files.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSerial Device Integration:\u003c\/strong\u003e Provides interface power for third-party subsystem communication via EIA-232 or EIA-422\/485 serial FTAs (e.g., Modbus RTU devices, weigh cells, multi-variable controllers).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcess Automation Subsystems:\u003c\/strong\u003e Serves as a power\/interface module in continuous process control, petrochemical refining, power generation, and chemical monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003eMC-TLPA02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e51309204-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Architecture\u003c\/td\u003e\n\u003ctd\u003eHigh-Performance Process Manager (HPM) \/ TPS \/ TDC 3000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSubsystem Network\u003c\/td\u003e\n\u003ctd\u003eUniversal Control Network (UCN) \/ Local Control Network (LCN)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoating\u003c\/td\u003e\n\u003ctd\u003eConformal Coated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eElectrical \u0026amp; Interface Capabilities\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Nominal DC Input\u003c\/td\u003e\n\u003ctd\u003e24 Vdc (via HPM Power System Distribution)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMultiplexer Compatibility\u003c\/td\u003e\n\u003ctd\u003eLLMux, RHMUX (Non-Incendive and Intrinsically Safe Power Adapters)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Protocols Supported\u003c\/td\u003e\n\u003ctd\u003eEIA-232 (RS-232), EIA-422\/485 (RS-422\/485)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCard File Compatibility\u003c\/td\u003e\n\u003ctd\u003e7-Slot and 15-Slot HPM \/ IOP Card Files\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous Location Support\u003c\/td\u003e\n\u003ctd\u003eCompatible with Division 2 \/ Zone 2 environments (when installed in approved enclosures)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Pre-Installation Inspection:\u003c\/strong\u003e Verify that the model number (MC-TLPA02) and part number (51309204-175) match your engineering system documentation before proceeding with installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Isolation:\u003c\/strong\u003e Ensure that cabinet main 24 Vdc power distribution is switched off or proper safety isolation protocols are followed prior to inserting or removing module cabling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Location:\u003c\/strong\u003e Install the adapter into its designated card file position or FTA mounting channel frame as defined by your HPM cabinet layout plan.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring \u0026amp; Shielding:\u003c\/strong\u003e Connect pre-fabricated IOP-to-Power Adapter cables and FTA interface cables. Ensure shield drain wires are properly grounded to the system reference ground to mitigate electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBus Grounding Checks:\u003c\/strong\u003e Confirm that the safety ground and master reference ground connections comply with single-point or multi-point grounding standards prior to energizing the subsystem.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eMaintenance Recommendations\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eVisual \u0026amp; Environmental Inspection:\u003c\/strong\u003e Periodically check the conformal coating for signs of mechanical degradation or thermal distress in high-ambient environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Continuity \u0026amp; Latch Verification:\u003c\/strong\u003e Ensure all multi-pin interface cables (IOP to Power Adapter, Power Adapter to FTA) are fully seated and secured by their retaining latches.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eParameter \u0026amp; System Diagnostics:\u003c\/strong\u003e Monitor system diagnostic logs at the TPS Universal Station\/HPM diagnostic level for any serial communication retries or multiplexer channel read errors.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667757691243,"sku":"MC-TLPA02 51309204-175","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/MC-TLPA02-51309204-175_003_1200x1200_7b8db7aa-a18b-48ab-8a1a-2c5f9495bd96.jpg?v=1786803162"},{"product_id":"honeywell-fc-sao-0220m-ccv1-0-safety-manager-safe-analog-output-module","title":"Honeywell FC-SAO-0220m CCV1.0 Safety Manager Safe Analog Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell FC-SAO-0220m\u003c\/strong\u003e is a Safe Analog Output Module featuring two 0(4)–20 mA output channels engineered for high-integrity safety control applications within the Honeywell Safety Manager system. Operating as a critical output interface, the module converts internal digital system logic commands into precise analog current loops to regulate modulating final control elements, valves, and positioners in safety-critical loops.\u003c\/p\u003e\n\u003cp\u003eDesigned with internal safety architecture, each channel contains a 12-bit D\/A converter for output signal generation and an integrated A\/D converter that continuously reads back the actual output value. Within a configured Diagnostic Test Interval, the module automatically tests output channels for output value accuracy (within ±5%), de-energization capability, and cross-talk between outputs. Each channel features a secondary means of de-energizing (SMOD), enabling the watchdog and processor to de-energize the output independently of the application command value.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell FC-SAO-0220m\u003c\/strong\u003e features conformal coating on all internal electronic assemblies (designated by the FC- prefix) to protect against airborne contaminants, dust, and aggressive industrial environments. The output channels are galvanically isolated from both the 24 Vdc internal power supply and the 5 Vdc logic supply.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProvides two 0(4)–20 mA safe analog output channels configurable as active or passive loops.\u003c\/li\u003e\n\u003cli\u003eConformally coated PCB construction (FC- prefix) for reliable environmental protection.\u003c\/li\u003e\n\u003cli\u003eDual-converter architecture utilizes a 12-bit D\/A converter for driving current and an internal A\/D converter for continuous signal read-back and self-testing.\u003c\/li\u003e\n\u003cli\u003eIncorporates continuous self-diagnostics verifying output current accuracy within ±5%, de-energization ability, and channel cross-talk.\u003c\/li\u003e\n\u003cli\u003eSecondary Means of De-energizing (SMOD) allows the watchdog or main processor to force channels to a de-energized state.\u003c\/li\u003e\n\u003cli\u003eGalvanically isolated outputs from the 5 Vdc and 24 Vdc supply buses.\u003c\/li\u003e\n\u003cli\u003eSupports both non-redundant and redundant Safety Manager I\/O configurations starting as of Safety Builder release 120.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Instrumented Systems (SIS):\u003c\/strong\u003e Converts safety shutdown logic into precise 4–20 mA positioning signals for emergency isolation and modulating control valves.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBurner Management Systems (BMS):\u003c\/strong\u003e Manages fuel-to-air ratio valves and flue gas damper actuators requiring safety-certified continuous signal conditioning.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire \u0026amp; Gas (F\u0026amp;G) Mitigation Systems:\u003c\/strong\u003e Controls variable output speed drives and proportional deluge valves.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Location Control:\u003c\/strong\u003e Interfaces with non-incendive field circuits in Class I, Division 2 environments via approved terminal assemblies.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003eFC-SAO-0220m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Version\u003c\/td\u003e\n\u003ctd\u003eCCV1.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eSafe Analog Output Module (0(4)–20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eHoneywell Safety Manager\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoating\u003c\/td\u003e\n\u003ctd\u003eConformal Coated (FC-Type)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003e4 TE, 3 HE (4 HP, 3U)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eElectrical \u0026amp; Power Ratings\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogic Power Requirements\u003c\/td\u003e\n\u003ctd\u003e5 Vdc, 30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 Vdc, 65 mA + 30 mA per active output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWDG Input Current\u003c\/td\u003e\n\u003ctd\u003e0.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eGalvanically isolated from 24 Vdc and 5 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon Pins\u003c\/td\u003e\n\u003ctd\u003e0 V 1 (d14) and 0 V 2 (d20) interconnected on module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eOutput Channels \u0026amp; Performance\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Output Channels\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal Range\u003c\/td\u003e\n\u003ctd\u003eActive or Passive, 0–20 mA \/ 4–20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD\/A Converter Resolution\u003c\/td\u003e\n\u003ctd\u003e12-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOff-State Current\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.05 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eActive Loop Resistance\u003c\/td\u003e\n\u003ctd\u003eMaximum 600 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eActive Maximum Output Voltage\u003c\/td\u003e\n\u003ctd\u003e30 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePassive External Voltage\u003c\/td\u003e\n\u003ctd\u003eMaximum 40 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePassive Minimum Voltage Drop\u003c\/td\u003e\n\u003ctd\u003e≤ 7.5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostic Voltage Accuracy\u003c\/td\u003e\n\u003ctd\u003eCurrent value ± 5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAllowed Load Types\u003c\/td\u003e\n\u003ctd\u003eResistive or capacitive only (inductive loads report module fault)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eMechanical Keying\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Keying Holes\u003c\/td\u003e\n\u003ctd\u003eHoles A9, C5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChassis Keying Pins\u003c\/td\u003e\n\u003ctd\u003eLarge pins A9, C5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Pin\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ed2\u003c\/td\u003e\n\u003ctd\u003eWatchdog (WDG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eb2\u003c\/td\u003e\n\u003ctd\u003eGround (GND)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ez2\u003c\/td\u003e\n\u003ctd\u003eLogic Power (+5 Vdc VCC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ed8\u003c\/td\u003e\n\u003ctd\u003eInternal Supply 24 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ez8\u003c\/td\u003e\n\u003ctd\u003eSupply 0 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ed14\u003c\/td\u003e\n\u003ctd\u003e0 V 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ed16\u003c\/td\u003e\n\u003ctd\u003emA 1 (Channel 1 Current Output)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ez16\u003c\/td\u003e\n\u003ctd\u003eLoop 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ed20\u003c\/td\u003e\n\u003ctd\u003e0 V 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ed22\u003c\/td\u003e\n\u003ctd\u003emA 2 (Channel 2 Current Output)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ez22\u003c\/td\u003e\n\u003ctd\u003eLoop 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eConfirm that the \u003cstrong\u003eHoneywell FC-SAO-0220m\u003c\/strong\u003e module version (CCV1.0) matches system software project requirements.\u003c\/li\u003e\n\u003cli\u003eInspect the rear connector pins and keying hole locations (A9, C5) to ensure compatibility with the card guide positioning pins.\u003c\/li\u003e\n\u003cli\u003eEnsure power to the target chassis section is safely disconnected before inserting the card, or verify hot-swap suitability in redundant configurations.\u003c\/li\u003e\n\u003cli\u003eAlign the card edge with the 4 TE chassis guide rails and push firmly into the backplane until properly seated.\u003c\/li\u003e\n\u003cli\u003eConnect the 24 Vdc internal supply to prevent fault detection during automatic self-test procedures.\u003c\/li\u003e\n\u003cli\u003eShort-circuit any unused output channels (link terminal 2 with 3 for channel 1, or terminal 6 with 7 for channel 2 on the TSAO-0220m FTA) to prevent fault reporting during self-diagnostic execution.\u003c\/li\u003e\n\u003cli\u003eDo not connect inductive loads directly to the outputs; the module is designed exclusively for resistive or capacitive loads.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eMaintenance \u0026amp; Replacement Recommendations\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundant Output Consideration:\u003c\/strong\u003e When replacing a module in redundant analog output configurations, note that a detected fault during self-testing may cause a minor current dip on the output before the Safety Manager switches control to the healthy redundant channel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFault Inspection:\u003c\/strong\u003e If a channel fault LED lights up, verify that inductive loads have not been connected to the outputs and ensure that all unused channels are properly jumpered.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eCE Marked\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eTÜV Certified\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eUL Listed\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCSA Certified\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFactory Mutual (FM):\u003c\/strong\u003e FM 3611 Approved for Class I, Division 2, Groups ABCD and Class II, Division 2, Groups FG non-incendive field circuits in hazardous locations.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667757887851,"sku":"FC-SAO-0220m CCV1.0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-fc-sao-022m-safe-analog-output-module-ixf4ffxblwj_1f38be25-3863-4b38-ac15-fec94132755c.jpg?v=1765501663"},{"product_id":"honeywell-mu-tsdm02-51303932-277-digital-input-module","title":"Honeywell MU-TSDM02 51303932-277 Digital Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell MU-TSDM02 51303932-277 is a specialized digital input module designed for integration within Honeywell Experion PKS and related distributed control systems. This hardware component serves as a reliable interface for acquiring discrete status signals from field devices such as limit switches, pushbuttons, and relay contacts, converting them into standard internal logic levels for the controller.\u003c\/p\u003e\n\u003cp\u003eEngineered for deployment in rigorous industrial process environments, the module supports dependable signal acquisition and integrates into standard Honeywell system architectures. It provides structured terminal connections and internal circuitry designed to maintain system stability and uptime across continuous process operations.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDesigned for integration within Honeywell distributed control system architectures\u003c\/li\u003e\n  \u003cli\u003eReliable discrete input signal acquisition for industrial field devices\u003c\/li\u003e\n  \u003cli\u003eBuilt for standard industrial panel mounting configurations\u003c\/li\u003e\n  \u003cli\u003eDirect compatibility with designated Honeywell system hardware and terminal assemblies\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDistributed Control Systems (DCS)\u003c\/li\u003e\n  \u003cli\u003eContinuous process manufacturing plants\u003c\/li\u003e\n  \u003cli\u003eOil and gas production facilities\u003c\/li\u003e\n  \u003cli\u003eChemical processing plants\u003c\/li\u003e\n  \u003cli\u003ePower generation control infrastructure\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eHoneywell\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eExact Model\u003c\/td\u003e\n      \u003ctd\u003eMU-TSDM02\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePart Number \/ SKU\u003c\/td\u003e\n      \u003ctd\u003e51303932-277\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003eDigital Input Module\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Series\u003c\/td\u003e\n      \u003ctd\u003eMU-T Series\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n      \u003ctd\u003eHoneywell DCS\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCountry of Origin\u003c\/td\u003e\n      \u003ctd\u003eUSA\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eVerify that the part number MU-TSDM02 51303932-277 matches your system engineering documentation.\u003c\/li\u003e\n  \u003cli\u003eDe-energize the corresponding system rack and associated power supplies before handling any hardware.\u003c\/li\u003e\n  \u003cli\u003eInspect the module and connector pins for any signs of transit damage or contamination.\u003c\/li\u003e\n  \u003cli\u003eSecurely seat the module into the designated slot within the system mounting structure.\u003c\/li\u003e\n  \u003cli\u003eConnect all field wiring to the appropriate terminal blocks in accordance with the loop diagrams.\u003c\/li\u003e\n  \u003cli\u003eRestore power and verify module status through the system engineering station diagnostics.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667759067499,"sku":"MU-TSDM02 51303932-277","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-mu-tsdm02-51303932-277-digital-input-module-0apobunluho_409891b3-7ea5-42b5-a78a-4d18ba2b3578.jpg?v=1765501677"},{"product_id":"honeywell-mc-tdor62-51309150-275-digital-output-module","title":"Honeywell MC-TDOR62 51309150-275 Digital Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell MC-TDOR62 (Model 51309150-275) is a high-density digital output module designed for use within Honeywell TDC 3000 and Experion PKS distributed control systems. This component interfaces control system logic with plant-floor actuators, solenoid valves, and relay banks, facilitating reliable discrete command execution in large-scale industrial automation architectures.\u003c\/p\u003e\n\u003cp\u003eBuilt for continuous operation in process manufacturing environments, the module handles discrete signal switching to drive external loads safely and efficiently. It integrates directly into the system infrastructure, communicating internal states and diagnostic data back to the central controller to ensure high availability and deterministic response times across the process loop.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eEngineered specifically for Honeywell TDC 3000 and Experion PKS control system integration\u003c\/li\u003e\n  \u003cli\u003eProvides discrete output channels for driving high-capacity industrial actuators and relays\u003c\/li\u003e\n  \u003cli\u003ePerforms internal channel-level diagnostics to monitor operational health and fault conditions\u003c\/li\u003e\n  \u003cli\u003eHot-swappable architecture allows for module replacement without shutting down the entire control rack\u003c\/li\u003e\n  \u003cli\u003eGalvanic isolation between field signals and internal system electronics to protect sensitive controllers\u003c\/li\u003e\n  \u003cli\u003eStatus LED indicators on the front panel provide real-time visual verification of output and power states\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOil and gas extraction and refining facilities\u003c\/li\u003e\n  \u003cli\u003eChemical and petrochemical processing plants\u003c\/li\u003e\n  \u003cli\u003ePower generation and turbine control systems\u003c\/li\u003e\n  \u003cli\u003ePulp and paper manufacturing lines\u003c\/li\u003e\n  \u003cli\u003eLarge municipal water and wastewater treatment works\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eHoneywell\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eExact Model\u003c\/td\u003e\n      \u003ctd\u003eMC-TDOR62\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCatalog \/ Ordering Number\u003c\/td\u003e\n      \u003ctd\u003e51309150-275\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003eDigital Output Module\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n      \u003ctd\u003eHoneywell TDC 3000 \/ Experion PKS\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCountry of Origin\u003c\/td\u003e\n      \u003ctd\u003eUnited States\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eElectrical \u0026amp; Mechanical\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMounting Type\u003c\/td\u003e\n      \u003ctd\u003eStandard System Rack \/ Chassis Slot\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEnclosure Protection\u003c\/td\u003e\n      \u003ctd\u003eIP20 (intended for installation within a controlled panel cabinet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNet Weight\u003c\/td\u003e\n      \u003ctd\u003e0.7 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eVerify the catalog and ordering number (51309150-275) against system engineering drawings before unboxing.\u003c\/li\u003e\n  \u003cli\u003eEnsure the target rack slot is completely de-energized to prevent electrical shock or damage to backplane pins.\u003c\/li\u003e\n  \u003cli\u003eInspect the module edge connectors and backplane pins for dust, bending, or physical damage.\u003c\/li\u003e\n  \u003cli\u003eAlign the module carefully with the designated rack guides and slide it firmly into position until fully seated.\u003c\/li\u003e\n  \u003cli\u003eSecure any retention fasteners or latching mechanisms specified for the chassis architecture.\u003c\/li\u003e\n  \u003cli\u003eApply system power and verify that the module status indicators transition to normal operational states.\u003c\/li\u003e\n  \u003cli\u003eConfigure and test channel functionality through the Experion PKS or TDC 3000 engineering workstation.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667759165803,"sku":"MC-TDOR62 51309150-275","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-mc-tdor62-51309150-275-digital-output-module-qf1qulu325c_da8dd984-8ede-463f-b7d0-3f5d1e1565b5.jpg?v=1765501679"},{"product_id":"honeywell-51196653-100-tdc-3000-five-slot-file-power-supply-module","title":"Honeywell 51196653-100 TDC 3000 Five-slot File Power Supply Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell 51196653-100\u003c\/strong\u003e is a chassis-mounted \u003cstrong\u003eTDC 3000 Five-slot File Power Supply\u003c\/strong\u003e engineered to provide stable operating power for Local Control Network (LCN) node chassis files within TotalPlant Solution (TPS) and TDC 3000 control architectures. Rated for 55 A output capacity, this power supply module energizes node processor boards, coprocessors, drive trays, and peripheral I\/O modules across the backplane file assembly.\u003c\/p\u003e\n\u003cp\u003eDesigned for high system availability, the \u003cstrong\u003e51196653-100\u003c\/strong\u003e features built-in voltage margining controlled by an accessible front jumper. This capability allows system engineers to adjust output voltage margins by +5% during diagnostic tests and factory troubleshooting. The module integrates a front-panel power switch, reset control, and dedicated status indicators to provide immediate local feedback on supply integrity.\u003c\/p\u003e\n\u003cp\u003eBuilt to meet European EMC and Health and Safety Directives, the CE-compliant \u003cstrong\u003eHoneywell 51196653-100\u003c\/strong\u003e incorporates standard 3-pin AC connector interface standards and high-efficiency fan cooling to ensure reliable thermal management in continuous industrial automation environments.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Capacity Current Delivery:\u003c\/strong\u003e Delivers up to 55 A of regulated power across the backplane to support multi-slot LCN node assemblies, processors, and disk trays.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Margining Test Capabilities:\u003c\/strong\u003e Equipped with a front-accessible jumper allowing +5% high-margin voltage adjustment for maintenance testing and troubleshooting routines.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Front-Panel Diagnostics:\u003c\/strong\u003e Includes a dedicated Power OK status LED, power switch, and manual reset button for real-time visual monitoring and control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE-Compliant Safety Architecture:\u003c\/strong\u003e Fully compliant with European Union EMC and Health and Safety Directives for industrial control enclosures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard Industrial AC Input:\u003c\/strong\u003e Features a standard 3-pin AC connector for simple, secure power entry connections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eForced-Air Thermal Management:\u003c\/strong\u003e Built-in fan assembly provides continuous internal cooling to maintain optimal operating temperatures within 5-slot file chassis.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTDC 3000 \u0026amp; TPS LCN Nodes:\u003c\/strong\u003e Main power conversion module for 5-slot file chassis housing Application ModuleX (AXM) processors, K2LCN, or K4LCN node boards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Control File Enclosures:\u003c\/strong\u003e Provides clean DC power distribution across shared backplanes for memory modules, coprocessor boards, and hard disk drive trays.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcess Automation Maintenance \u0026amp; Retrofits:\u003c\/strong\u003e Replacement chassis power supply module for legacy DCS infrastructure during system upgrades and maintenance overhauls.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003e51196653-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eTDC 3000 Five-slot File Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current Rating\u003c\/td\u003e\n\u003ctd\u003e55 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Margining Options\u003c\/td\u003e\n\u003ctd\u003e+5% High Margin (Factory\/Test Jumper Controlled)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow Margin Limit\u003c\/td\u003e\n\u003ctd\u003e-5% (Restricted from use in AXM file chassis)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront Panel Controls\u003c\/td\u003e\n\u003ctd\u003ePower On\/Off Switch, Reset Button, Margining Jumper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront Panel Indicators\u003c\/td\u003e\n\u003ctd\u003ePower OK LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Connection\u003c\/td\u003e\n\u003ctd\u003eStandard 3-pin connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Compatibility\u003c\/td\u003e\n\u003ctd\u003e5-Slot LCN Node Chassis \/ File Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eIntegrated Fan Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance\u003c\/td\u003e\n\u003ctd\u003eCE-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Pre-Check:\u003c\/strong\u003e Disconnect primary AC source power before inserting or removing the power supply from the file chassis. Ensure proper ESD protective grounding procedures are observed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eJumper Verification:\u003c\/strong\u003e Verify that the front voltage margin jumper is locked in the Normal (\"Norm\") position prior to powering on process-active equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Alignment:\u003c\/strong\u003e Slide the power supply module smoothly into the left-hand power slot of the 5-slot file chassis until backplane connectors seat firmly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Power Connection:\u003c\/strong\u003e Connect the primary power line using the standard 3-pin connector interface.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Startup:\u003c\/strong\u003e Apply power using the front-panel toggle switch. Verify that the green \"Power OK\" LED turns on and fan airflow is active.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eReplacement Recommendations\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSoftware Shutdown Prior to Power-Off:\u003c\/strong\u003e Always perform an orderly software shutdown of node processor software and coprocessor operating systems (such as HP-UX on AXM nodes) prior to switching off or removing the power supply. Removing power unannounced can result in corrupted file systems on hard disk drive trays.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Margining Restrictions:\u003c\/strong\u003e The low power margin option (-5%) must \u003cstrong\u003eNEVER\u003c\/strong\u003e be selected on chassis containing AXM nodes or hard drive trays, as their hardware design requires a tight power supply tolerance (maximum -2.5% drop). Operating on low margin will cause unpredictable system behavior or disk faults.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn-Process Restrictions:\u003c\/strong\u003e Do not execute high (+5%) or low (-5%) margin tests while the node is actively controlling or participating in an online process.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667759559019,"sku":"51196653-100","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-51196653-100-tdc-3000-five-slot-file-power-supply-hid4xug3c1l_599db822-3779-4818-a011-a23882dc7f5e.jpg?v=1765501685"},{"product_id":"honeywell-fc-cpchas-0001-safety-manager-module","title":"Honeywell FC-CPCHAS-0001 Safety Manager Controller Chassis","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell FC-CPCHAS-0001\u003c\/strong\u003e is a 19-inch rack-mounted Controller Chassis engineered to house and interface the Control Processor modules within the Honeywell Safety Manager system architecture. Installed as the main processing enclosure at the top position of a system cabinet, it provides structural housing and complete backplane interconnection for both redundant and non-redundant Safety Manager controller configurations.\u003c\/p\u003e\n\u003cp\u003eThe chassis integrates a specialized controller housing with card guides, quarter-turn module locks, and a integrated controller backplane (CPB-0001). The rear section features a magnetically locked back cover plate that swings upward to expose signal connections and a structured cable-management framework with dedicated horizontal bars for 24 Vdc supply\/signals, communication links, and 5V\/Watchdog lines. The unit routes internal power distribution—including a diode-decoupled, redundant 5V supply (5V-R) derived from connected power supply units—and interfaces up to four I\/O buses, watchdog outputs, system power, and communication lines to field I\/O racks and external networks.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual-Configuration Flexibility:\u003c\/strong\u003e Supports both single (non-redundant) and fault-tolerant redundant Control Processor setups within a single standard 19-inch housing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Backplane Architecture:\u003c\/strong\u003e Incorporates the CPB-0001 controller backplane to deliver signal routing, 5V-R diode-decoupled redundant power distribution, and I\/O bus connections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStructured Rear Cable Management:\u003c\/strong\u003e Features three dedicated horizontal tie-wrap bars to separate 24 Vdc power\/signals, communication cables, and low-voltage 5V\/watchdog cabling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwing-Up Rear Protection:\u003c\/strong\u003e Magnetically locked rear cover plate swings upward for easy access to backplane connectors during installation and maintenance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComprehensive Expansion Capability:\u003c\/strong\u003e Offers interfaces for up to 4 I\/O buses with dedicated terminator sockets (TERM-0001\/TERM-0002) and 8 watchdog\/power distribution channels (WdP1–WdP8) for downstream I\/O chassis connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDedicated Control Inputs:\u003c\/strong\u003e Includes external Emergency Shut Down (SD) interlock terminals and 3 non-safety 24 Vdc general-purpose inputs (IN1–IN3) for functions such as external clock synchronization.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Manager Main Controller Enclosure:\u003c\/strong\u003e Primary processing hub housing Quad Processor Packs (QPP-0002), Universal Safety Interfaces (USI-0002 \/ FX-USI-0002), Power Supplies (PSU-240516), and Battery \u0026amp; Key Switch Modules (BKM-0001).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEmergency Shutdown (ESD) Systems:\u003c\/strong\u003e Core chassis housing for ESD logic solvers in process plants, offshore platforms, and refineries.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBurner Management Systems (BMS) \u0026amp; Fire \u0026amp; Gas (F\u0026amp;G):\u003c\/strong\u003e Central hardware frame for processing high-integrity safety loops and fire\/gas monitoring logic.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExact Model\u003c\/td\u003e\n\u003ctd\u003eFC-CPCHAS-0001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType Number\u003c\/td\u003e\n\u003ctd\u003eFS-CPCHAS-0001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eController Chassis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame \/ Mounting Standard\u003c\/td\u003e\n\u003ctd\u003e19-inch Rack Cabinet Mount (4 HE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption (5V-1)\u003c\/td\u003e\n\u003ctd\u003e0.05 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption (5V-2)\u003c\/td\u003e\n\u003ctd\u003e0.05 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eSlot \u0026amp; Module Capacity\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Processor Slots\u003c\/td\u003e\n\u003ctd\u003eCPU1 (QPP-0002), CPU2 (QPP-0002, optional for redundancy)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Slots\u003c\/td\u003e\n\u003ctd\u003eCOM1.1, COM1.2, COM2.1, COM2.2 (USI-0002 \/ FX-USI-0002 or BLIND-COM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Slots\u003c\/td\u003e\n\u003ctd\u003ePSU1 (PSU-240516), PSU2 (PSU-240516, optional for redundancy)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShared Module Slot\u003c\/td\u003e\n\u003ctd\u003eBKM (BKM-0001 Battery and Key Switch Module)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnused Slot Cover Plate\u003c\/td\u003e\n\u003ctd\u003eBLIND-CPS (for non-redundant CPU\/PSU slots)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eMechanical \u0026amp; Environmental\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e4 HE (177 mm \/ 7 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e482.6 mm \/ 19 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e280 mm \/ 11 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e5.8 kg \/ 12.8 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRear Cover Locking\u003c\/td\u003e\n\u003ctd\u003eMagnetic lock mechanism\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Group\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOM1.1.A \/ B, COM1.2.A \/ B\u003c\/td\u003e\n\u003ctd\u003eRJ45\u003c\/td\u003e\n\u003ctd\u003eEthernet communication channels 1 and 2 for CP1 modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOM1.1.C \/ D, COM1.2.C \/ D\u003c\/td\u003e\n\u003ctd\u003e10-pin male\u003c\/td\u003e\n\u003ctd\u003eGeneral purpose communication channels 3 and 4 for CP1 modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOM2.1.A \/ B, COM2.2.A \/ B\u003c\/td\u003e\n\u003ctd\u003eRJ45\u003c\/td\u003e\n\u003ctd\u003eEthernet communication channels 1 and 2 for CP2 modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOM2.1.C \/ D, COM2.2.C \/ D\u003c\/td\u003e\n\u003ctd\u003e10-pin male\u003c\/td\u003e\n\u003ctd\u003eGeneral purpose communication channels 3 and 4 for CP2 modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIO bus 1 to 4 (1.1–1.4 \u0026amp; 2.1–2.4)\u003c\/td\u003e\n\u003ctd\u003eFlat cable connectors\u003c\/td\u003e\n\u003ctd\u003eI\/O bus interface links for Control Processor 1 and Control Processor 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerm IO bus 1 to 4\u003c\/td\u003e\n\u003ctd\u003e2 x 50-pin connector\u003c\/td\u003e\n\u003ctd\u003eSockets for IO bus terminators (TERM-0001 or TERM-0002)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWdP1 to WdP8\u003c\/td\u003e\n\u003ctd\u003e8-pin male\u003c\/td\u003e\n\u003ctd\u003eWatchdog and Power distribution connectors to I\/O chassis 1 through 8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e24V-1 \/ 24V-2\u003c\/td\u003e\n\u003ctd\u003e2-pin male\u003c\/td\u003e\n\u003ctd\u003eMain +24V power supply inputs for CP1 and CP2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5V-1 \/ 5V-2 \/ 5V-R\u003c\/td\u003e\n\u003ctd\u003e4-pin male\u003c\/td\u003e\n\u003ctd\u003e5V and Watchdog distribution to extension cabinets via PDB-IOX05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSD\u003c\/td\u003e\n\u003ctd\u003e2-pin male\u003c\/td\u003e\n\u003ctd\u003eEmergency Shut Down loop input (shunted via LINK-SD if unused)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN1, IN2, IN3\u003c\/td\u003e\n\u003ctd\u003e2-pin male\u003c\/td\u003e\n\u003ctd\u003e24V non-safety general purpose inputs (IN1 supports clock sync interrupt)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack Mounting:\u003c\/strong\u003e Install the \u003cstrong\u003eHoneywell FC-CPCHAS-0001\u003c\/strong\u003e horizontally into a standard 19-inch rack cabinet, typically positioned at the top location above the associated I\/O chassis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding Verification:\u003c\/strong\u003e Ensure the chassis is bonded to the main cabinet frame ground. Built-in keying pins in the backplane provide chassis ground connection to module housings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Insertion:\u003c\/strong\u003e Insert modules (QPP-0002, USI-0002, PSU-240516, BKM-0001) along the top and bottom guide rails through the front opening. Secure each module by tightening the quarter-turn fasteners below the module grips.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBlanking Plates:\u003c\/strong\u003e Fit BLIND-CPS plates over unused processor\/power supply slots and BLIND-COM plates over unused communication slots to prevent airflow bypass and contamination.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRear Cable Management:\u003c\/strong\u003e Swing open the rear magnetic cover plate. Group and secure cables to the horizontal tie-wrap bars according to voltage levels:\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTop Bar:\u003c\/strong\u003e 24 Vdc supply and 24 Vdc signal wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMiddle Bar:\u003c\/strong\u003e System Ethernet and general-purpose communication cables.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBottom Bar:\u003c\/strong\u003e 5V auxiliary and Watchdog distribution cables.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Bus Termination:\u003c\/strong\u003e Verify that appropriate bus terminators (TERM-0001 or TERM-0002) are fully seated in all active Term IO bus sockets on the rear backplane.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEmergency Shutdown Link:\u003c\/strong\u003e Ensure the factory-installed LINK-SD jumper remains connected across the SD terminals unless an external hardwired Emergency Shut Down contact is wired to the chassis.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eConfiguration and Commissioning Recommendations\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply Redundancy Check:\u003c\/strong\u003e Measure voltage at 5V-1, 5V-2, and 5V-R backplane test terminals. Confirm that 5V-R remains energized when either power supply module (PSU1 or PSU2) is operational.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Verification:\u003c\/strong\u003e Verify link activity on RJ45 ports (COM1.1–COM2.2) when connected to system switches or downstream Safety Manager networks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterrupt \u0026amp; Clock Sync Verification:\u003c\/strong\u003e If using IN1 for clock synchronization, verify rising-edge signal integrity and line voltage levels before enabling software interrupts.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e European Conformity\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL:\u003c\/strong\u003e Underwriters Laboratories\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTUV:\u003c\/strong\u003e TÜV Certified for Functional Safety\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFM:\u003c\/strong\u003e Factory Mutual Approved\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667759985003,"sku":"FC-CPCHAS-0001","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/FC-CPCHAS-0001_003_1200x1200_9b3fefad-c381-4c0f-a110-f8e69b545975.jpg?v=1786801693"},{"product_id":"honeywell-51309206-125-universal-xpm-charger-circuit-board-rev-b","title":"Honeywell 51309206-125 Universal XPM Charger Circuit Board Rev B","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell 51309206-125 Rev B\u003c\/strong\u003e is a \u003cstrong\u003eUniversal XPM Charger Circuit Board\u003c\/strong\u003e designed for process control and DCS power subsystem management within Honeywell industrial systems. Functioning as a dedicated battery charger and power regulation assembly, this module manages power delivery, battery charging cycles, and status monitoring for Process Manager \/ Extended Process Manager (XPM) field enclosures and control racks.\u003c\/p\u003e\n\u003cp\u003eBuilt on a high-reliability industrial printed circuit board assembly (Assembly No. \u003cstrong\u003e51309206-125\u003c\/strong\u003e), the card incorporates integrated voltage regulation, current limiting circuitry, onboard fuse protection, and signaling relays. Interface connection to the backplane or system chassis is established via an onboard multi-pin DIN 41612 standard connector (DIN 48CPC connector marked J1).\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUniversal XPM charger board architecture for Honeywell process control subsystem power management\u003c\/li\u003e\n\u003cli\u003eIntegrated power switching and linear\/switching voltage regulation components with heatsink thermal dissipation\u003c\/li\u003e\n\u003cli\u003eOnboard fuse holder (F1) providing hardware-level overcurrent protection\u003c\/li\u003e\n\u003cli\u003eSolid-state logic ICs and onboard electromechanical relay for battery status switching and alarm outputs\u003c\/li\u003e\n\u003cli\u003eStandard DIN 41612 (48-pin) connector interface (J1) for direct backplane insertion and signal routing\u003c\/li\u003e\n\u003cli\u003eMulti-stage resistor-capacitor filtering network for stable DC output conditioning\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBattery charging and power backup regulation in Honeywell TDC 3000 \/ Process Manager systems\u003c\/li\u003e\n\u003cli\u003ePower distribution and monitoring inside Extended Process Manager (XPM) cabinets\u003c\/li\u003e\n\u003cli\u003eReplacement circuit assembly for industrial DCS power supply units and battery backup modules\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e51309206-125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRevision\u003c\/td\u003e\n\u003ctd\u003eRev B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssembly Description\u003c\/td\u003e\n\u003ctd\u003eUniversal XPM Charger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePrinted Circuit Board \/ Power Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eHoneywell Process Manager \/ XPM Subsystems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Connector Interface\u003c\/td\u003e\n\u003ctd\u003eDIN 41612 48-Pin Male Connector (J1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtective Components\u003c\/td\u003e\n\u003ctd\u003eOnboard Fuse (F1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eJ1 Connector\u003c\/td\u003e\n\u003ctd\u003e48-Pin DIN 41612 backplane edge connector for DC power input, charge output, and system status signaling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eConfirm system DC power is isolated and battery leads are safely disconnected before removing or installing the board.\u003c\/li\u003e\n\u003cli\u003eObserve proper ESD (electrostatic discharge) safety precautions, including grounding wrist straps, when handling the circuit assembly.\u003c\/li\u003e\n\u003cli\u003eInspect the board visually for physical damage, blown fuses, or loose components prior to mounting.\u003c\/li\u003e\n\u003cli\u003eAlign the board carefully with the chassis card guides and push firmly until the J1 DIN connector seats completely into the backplane socket.\u003c\/li\u003e\n\u003cli\u003eRe-engage rack mechanical locks or retention screws before restoring system power and battery connections.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eReplacement Recommendations\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Isolation:\u003c\/strong\u003e Fully disconnect primary AC\/DC input power and battery backup lines before swapping the board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuse Inspection:\u003c\/strong\u003e Verify that the replacement unit has the correct fuse rating installed in position F1 before power-up.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePost-Replacement Checks:\u003c\/strong\u003e Upon restoring power, measure charge output voltage across battery terminals to verify proper charger regulation.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667760476523,"sku":"51309206-125","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/51309206-125_001_1200x1200_5444eb07-6338-4634-bc54-18517c33a2c8.jpg?v=1787661136"},{"product_id":"honeywell-8c-sheda1-51307186-175-series-8-digital-input-board","title":"Honeywell 8C-SHEDA1 51307186-175 Series 8 Digital Input Board","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell \u003cstrong\u003e8C-SHEDA1\u003c\/strong\u003e (model 51307186-175) is a specialized digital input board designed for deployment within Honeywell Series 8 distributed control systems. This header board interfaces discrete field signals with automation infrastructure, providing reliable signal routing and system communication.\u003c\/p\u003e\n\u003cp\u003eEngineered for continuous industrial process control environments, the module supports standard automation architectures and facilitates stable data exchange between field instrumentation and the broader control network. Its specialized hardware layout ensures dependable performance in demanding monitoring and control tasks.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDesigned specifically for integration within Honeywell Series 8 control infrastructure\u003c\/li\u003e\n  \u003cli\u003eFacilitates reliable processing and routing of discrete digital input signals\u003c\/li\u003e\n  \u003cli\u003eConstructed for continuous operation in standard industrial temperature ranges\u003c\/li\u003e\n  \u003cli\u003eEmploys secure connection interfaces to maintain uninterrupted signal integrity\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDistributed Control Systems (DCS) for process manufacturing\u003c\/li\u003e\n  \u003cli\u003eOil and gas refining and petrochemical processing plants\u003c\/li\u003e\n  \u003cli\u003ePower generation and utility automation systems\u003c\/li\u003e\n  \u003cli\u003eChemical production and heavy industrial monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eHoneywell\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Series\u003c\/td\u003e\n      \u003ctd\u003eSeries 8\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModel \/ Part Number\u003c\/td\u003e\n      \u003ctd\u003e8C-SHEDA1\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCatalog Number\u003c\/td\u003e\n      \u003ctd\u003e51307186-175\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModule Type\u003c\/td\u003e\n      \u003ctd\u003eDigital Input Board \/ Header Board\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSystem Platform\u003c\/td\u003e\n      \u003ctd\u003eHoneywell Experion \/ Series 8 DCS\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCountry of Origin\u003c\/td\u003e\n      \u003ctd\u003eUnited States\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eVerify that the part number 8C-SHEDA1 51307186-175 matches system engineering documentation before proceeding.\u003c\/li\u003e\n  \u003cli\u003eDe-energize the associated Series 8 chassis and disconnect all power sources prior to physical handling.\u003c\/li\u003e\n  \u003cli\u003eInspect the board connectors and pins for any signs of transit damage or contamination.\u003c\/li\u003e\n  \u003cli\u003eMount the digital input board securely into the designated Series 8 slot in accordance with hardware layout rules.\u003c\/li\u003e\n  \u003cli\u003eConnect field wiring and interface cables securely to the appropriate terminal points.\u003c\/li\u003e\n  \u003cli\u003eRestore system power and verify module status indicators through the engineering workstation.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667761328491,"sku":"8C-SHEDA1 51307186-175","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-8c-sheda1-51307186-175-digital-input-board-ab2ocz10421_919ad80c-b915-4b1a-969a-2b50be7bd7b2.jpg?v=1765501713"},{"product_id":"honeywell-fc-sai-1620m-safe-high-density-analog-input-module","title":"Honeywell FC-SAI-1620M Safe High-Density Analog Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell FC-SAI-1620M\u003c\/strong\u003e is a conformal-coated, safe high-density analog input module engineered for high-integrity process safeguarding and critical automation applications within the \u003cstrong\u003eHoneywell Safety Manager\u003c\/strong\u003e system platform. Operating on a \u003cstrong\u003e24 Vdc\u003c\/strong\u003e power supply, this module provides 16 dedicated analog input channels designed to interface with 0(4)–20 mA field transmitters and process instrumentation. It plays a key role in acquiring analog process variables and routing signal data over the internal \u003cstrong\u003eSafety Manager IO Bus\u003c\/strong\u003e directly to the Quad Processor Pack (QPP) for high-integrity safety logic processing.\u003c\/p\u003e\n\u003cp\u003eDesigned to meet stringent functional safety standards up to \u003cstrong\u003eSIL3\u003c\/strong\u003e per \u003cstrong\u003eIEC 61508\u003c\/strong\u003e, the \u003cstrong\u003eFC-SAI-1620M\u003c\/strong\u003e executes continuous internal diagnostic self-tests within a defined Diagnostic Test Interval (DTI). Its conformal coating protects the internal Eurocard circuit board against harsh industrial environments, ensuring reliable long-term performance in Emergency Shutdown (ESD), Fire and Gas (F\u0026amp;G) detection, and Burner Management Systems (BMS).\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConformal Coating:\u003c\/strong\u003e Formulated with protective coating (FC prefix) to resist environmental contaminants, moisture, and corrosive airborne elements in harsh plant environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Density Channel Layout:\u003c\/strong\u003e Features 16 safe analog input channels within a compact 3U \/ 4HP Eurocard form factor to maximize cabinet rack space.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSIL3 Functional Integrity:\u003c\/strong\u003e Fully certified for use in safety instrumented functions up to Safety Integrity Level 3 in both single and Quadruple Modular Redundant (QMR) architectures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComprehensive Self-Diagnostics:\u003c\/strong\u003e Conducts automatic, background diagnostic testing of internal circuitry and signal paths within the Diagnostic Test Interval (DTI) to detect and isolate hardware anomalies safely.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Termination Assembly Integration:\u003c\/strong\u003e Connects seamlessly to external Field Termination Assemblies (such as TSAI-1620m or TSHART-1620m) using standard System Interconnection Cables (FS-SIC-0001).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHot-Swappable Subsystem Architecture:\u003c\/strong\u003e Integrates into the Safety Manager IO chassis backplane via standard 32-pin DIN 41612F connectors with key coding to prevent improper module insertion.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcess Safeguarding \u0026amp; ESD:\u003c\/strong\u003e Monitors critical process instrumentation (pressure, temperature, flow, level) for Emergency Shutdown loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire \u0026amp; Gas (F\u0026amp;G) Monitoring:\u003c\/strong\u003e Interfaces with analog gas and flame detectors in hydrocarbon processing and off-shore facilities.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBurner Management Systems (BMS):\u003c\/strong\u003e Safe tracking of fuel pressures, airflow, and flame intensity signals in boiler and furnace control applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTurbine \u0026amp; Compressor Protection:\u003c\/strong\u003e Continuous monitoring of operating variables to prevent surge, overpressure, or mechanical overspeed conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFC-SAI-1620M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number Prefix\u003c\/td\u003e\n\u003ctd\u003eFC (Conformal Coated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eSafety Manager\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eSafe High-Density Analog Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e16 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Voltage\u003c\/td\u003e\n\u003ctd\u003e24 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Range\u003c\/td\u003e\n\u003ctd\u003e0–20 mA \/ 4–20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafe Failure Fraction (SFF)\u003c\/td\u003e\n\u003ctd\u003e≥ 99%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Integrity Level\u003c\/td\u003e\n\u003ctd\u003eUp to SIL3 (IEC 61508 \/ ISA S84.01)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Form Factor\u003c\/td\u003e\n\u003ctd\u003eEurocard (100 x 160 mm \/ 3.94 x 6.30 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel Dimensions\u003c\/td\u003e\n\u003ctd\u003eHeight: 3U (3 HE), Width: 4HP (4 TE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003e32-pin DIN 41612F connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-5 degC to 70 degC (14 degF to 158 degF) ambient\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-25 degC to 80 degC (-13 degF to 176 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration Tolerance\u003c\/td\u003e\n\u003ctd\u003eIEC 60068-2-6; 1 G at 57 Hz to 150 Hz; 0.075 mm from 10 Hz to 57 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock Resistance\u003c\/td\u003e\n\u003ctd\u003eIEC 60068-2-27; 15 G for 11 ms, 3 axes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnection Point\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Connector\u003c\/td\u003e\n\u003ctd\u003eStandard 32-pin DIN 41612F Eurocard interface with mechanical keying\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Cable Interface\u003c\/td\u003e\n\u003ctd\u003eConnects to Field Termination Assembly (TSAI-1620m \/ TSHART-1620m) via FS-SIC-0001 System Interconnection Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Bus Link\u003c\/td\u003e\n\u003ctd\u003eCommunicates with the Control Processor via the Safety Manager horizontal and vertical IO Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003ePre-Installation Inspection:\u003c\/strong\u003e Verify that the module model code (\u003cstrong\u003eFC-SAI-1620M\u003c\/strong\u003e) matches project drawings and check the conformal coating for any physical damage prior to installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Off Rack Section:\u003c\/strong\u003e Ensure supply power to the target slot or chassis segment is turned off or isolated according to plant safety procedures before inserting non-redundant hardware.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlign and Seat Module:\u003c\/strong\u003e Carefully align the Eurocard edges with the card guides in the 3U slot of the \u003cstrong\u003eIOCHAS\u003c\/strong\u003e chassis. Push firmly until the 32-pin DIN 41612F connector seats completely into the backplane.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSecure Fasteners:\u003c\/strong\u003e Tighten top and bottom retaining screws on the front panel to guarantee proper grounding and mechanical stability under vibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCabling to FTA:\u003c\/strong\u003e Connect the System Interconnection Cable (FS-SIC-0001) from the rear backplane port to the corresponding Field Termination Assembly (TSAI-1620m or TSHART-1620m).\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eConfiguration \/ Commissioning \/ Replacement\u003c\/h3\u003e\n\u003ch3\u003eConfiguration Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDefine channel parameters and signal ranges (0–20 mA or 4–20 mA) in the \u003cstrong\u003eSafety Builder\u003c\/strong\u003e software environment using Point Configurator.\u003c\/li\u003e\n\u003cli\u003eConfigure channel-specific fault reaction states (e.g., Top Scale, Bottom Scale, Scan, or Hold) according to loop safety requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommissioning Recommendations\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePerform field signal loop checks from the transmitter through the FTA to the Safety Builder station to verify live reading accuracy.\u003c\/li\u003e\n\u003cli\u003eValidate diagnostic trip thresholds and verify that input discrepancies trigger appropriate alarms on the station HMI without tripping operational process loops prematurely.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplacement Recommendations\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eParameter Backup:\u003c\/strong\u003e Confirm the project logic and I\/O map database are fully backed up in Safety Builder prior to replacing an existing module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHardware Matching:\u003c\/strong\u003e Ensure the replacement module carries the conformal-coated \u003cstrong\u003eFC-SAI-1620M\u003c\/strong\u003e designation to maintain environmental resistance ratings in critical areas.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunctional Safety:\u003c\/strong\u003e Certified by TÜV to IEC 61508 Parts 1–7 (SIL3 capable) and ANSI\/ISA S84.01.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard ESD\/ESD:\u003c\/strong\u003e Compliant with DIN V VDE 19250, DIN V VDE 0801, and UL 1998 \/ UL 508.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Locations:\u003c\/strong\u003e CSA certified (C22.2 No. 142-M1987) and FM 3611 Class I, Division 2 compliant.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE Compliance:\u003c\/strong\u003e Conforms to European Directives 89\/336\/EEC (EMC) and 73\/23\/EEC (Low Voltage Directive).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Immunity:\u003c\/strong\u003e Tested to IEC 61000-4-2 (ESD Level 4), IEC 61000-4-3 (Radiated), IEC 61000-4-4 (Burst Level 3), and IEC 61000-4-5 (Surge Level 3).\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667762245995,"sku":"FC-SAI-1620","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/FC-SAI-1620M_001_1200x1200_6d81dedb-dbb0-4fb3-8ab9-2103e215ef96.jpg?v=1786792912"},{"product_id":"honeywell-fta-t-21-fail-safe-digital-input-fta","title":"Honeywell FTA-T-21 Fail-Safe Digital Input FTA","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell \u003cstrong\u003eFTA-T-21\u003c\/strong\u003e is a Fail-Safe Digital Input Field Termination Assembly (FTA) engineered for use within Honeywell Fail-Safe Control (FSC) safety instrumented systems. This specialized interface module provides secure signal conditioning and terminal connection for critical digital input loops, ensuring high reliability and fault tolerance in safety-critical industrial environments.\u003c\/p\u003e\n\u003cp\u003eThe unit acts as an essential intermediary between field sensors and the FSC controller architecture, facilitating safe signal transmission for emergency shutdown (ESD) systems, fire and gas monitoring, and other high-integrity automation loops. Its robust design maintains loop integrity and helps prevent spurious trips while supporting rigorous plant safety requirements.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDesigned specifically for Honeywell Fail-Safe Control (FSC) systems\u003c\/li\u003e\n  \u003cli\u003eFail-safe digital input signal termination and conditioning\u003c\/li\u003e\n  \u003cli\u003eRobust industrial construction for high-availability safety loops\u003c\/li\u003e\n  \u003cli\u003eDirect field wiring termination for simplified maintenance and reduced downtime\u003c\/li\u003e\n  \u003cli\u003eEngineered to maintain strict signal integrity in demanding process areas\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eEmergency Shutdown Systems (ESD)\u003c\/li\u003e\n  \u003cli\u003eFire and Gas (F\u0026amp;G) Protection Systems\u003c\/li\u003e\n  \u003cli\u003eCritical process industries including oil and gas, petrochemicals, and power generation\u003c\/li\u003e\n  \u003cli\u003eHigh-integrity discrete sensor signal routing\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eHoneywell\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Model\u003c\/td\u003e\n      \u003ctd\u003eFTA-T-21\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003eFail-Safe Digital Input FTA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Family\u003c\/td\u003e\n      \u003ctd\u003eHoneywell FSC System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMounting Type\u003c\/td\u003e\n      \u003ctd\u003ePanel Mount\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEnclosure Protection\u003c\/td\u003e\n      \u003ctd\u003eIP20\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCountry of Origin\u003c\/td\u003e\n      \u003ctd\u003eUSA\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eInterface\u003c\/th\u003e\n      \u003cth\u003eFunction\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eField Terminals\u003c\/td\u003e\n      \u003ctd\u003eScrew terminals for connecting field digital input sensors and switches\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eController Interface\u003c\/td\u003e\n      \u003ctd\u003eDedicated cable connection to the Honeywell FSC input module\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eVerify the part number and inspect the FTA-T-21 module for any physical transit damage prior to installation.\u003c\/li\u003e\n  \u003cli\u003eDe-energize all associated power sources and field circuits before beginning mechanical or electrical work.\u003c\/li\u003e\n  \u003cli\u003eMount the FTA securely to the designated panel using standard hardware within the control cabinet.\u003c\/li\u003e\n  \u003cli\u003eConnect field sensor wiring to the appropriate terminal blocks, ensuring proper torque and secure wire retention.\u003c\/li\u003e\n  \u003cli\u003eAttach the system cable linking the FTA-T-21 to the corresponding Honeywell FSC I\/O module.\u003c\/li\u003e\n  \u003cli\u003ePerform a complete loop check and verify signal status through the Experion or FSC programming environment before commissioning.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667762671979,"sku":"FTA-T-21","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-fta-t-21-fail-safe-digital-input-fta-sclar3bixma_d25dd062-fc07-4ac3-98d7-c668ef474b80.jpg?v=1765501734"},{"product_id":"honeywell-sc-pcmx01-51307195-175-rtu2020-controller-cpm","title":"Honeywell SC-PCMX01 51307195-175 RTU2020 Controller CPM","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell SC-PCMX01 51307195-175\u003c\/strong\u003e is a control processor module (CPM) designed for the RTU2020 Remote Terminal Unit system. Equipped with 28 mixed onboard I\/O, this module provides localized control and interface capabilities for remote automation tasks. The unit features a dual core ARM Cortex-A9 processor running at 667 MHz with a 32-bit data bus, supporting real-time data execution and onboard I\/O operations. Integrated HART functionality enables direct digital communication with connected field instrumentation without requiring external expansion hardware. Communication protocols including Modbus RTU\/ASCII\/TCP, DNP3, and HART-IP are supported across dual Ethernet and four serial ports for seamless integration into SCADA and Experion PKS environments.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBuilt with a dual core ARM Cortex-A9 667 MHz processor, 128 MB RAM, and 32 MB Flash memory.\u003c\/li\u003e\n\u003cli\u003eIncludes 28 mixed onboard I\/O channels (8 AI, 2 AO, 10 DI, 6 DO, and 2 PI\/DI) with transient suppression on every channel.\u003c\/li\u003e\n\u003cli\u003eFeatures HART-enabled onboard I\/O with HART-IP support via Ethernet for remote field device management.\u003c\/li\u003e\n\u003cli\u003eEquipped with dual 10\/100BaseTx RJ45 Ethernet ports and four serial ports (2x RS232 RJ45 and 2x RS485 screw terminals).\u003c\/li\u003e\n\u003cli\u003eSupports Modbus RTU\/ASCII\/TCP and DNP3 protocols in master, slave, and outstation roles.\u003c\/li\u003e\n\u003cli\u003eDesigned with a built-in SD card slot supporting up to 32GB industry-standard SD cards for extended data logging.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRemote oil and gas field automation, wellhead monitoring, and pipeline control.\u003c\/li\u003e\n\u003cli\u003eSCADA interface operations with Experion PKS or third-party monitoring systems.\u003c\/li\u003e\n\u003cli\u003eHART field device integration and remote asset management.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSC-PCMX01\u003c\/td\u003e\n\u003ctd\u003eRTU2020 controller CPM, 28 mixed onboard I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSC-UCMX01\u003c\/td\u003e\n\u003ctd\u003e1 RTU2020 Non-redundant Controller with 28 mixed onboard I\/O (Includes 1 x SC-PCMX01 and 1 x SC-TCMX01)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSC-TCMX01\u003c\/td\u003e\n\u003ctd\u003eRTU2020 controller IOTA, 28 mixed I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSP-IHARTP\u003c\/td\u003e\n\u003ctd\u003eHART Protocol Enabler License\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSP-EBLDR1\u003c\/td\u003e\n\u003ctd\u003eRTU Builder software license\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor\u003c\/td\u003e\n\u003ctd\u003eDual Core ARM Cortex-A9 Core (32 bit data bus) 667 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDynamic Memory (RAM)\u003c\/td\u003e\n\u003ctd\u003e128 Megabytes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgram Memory (Flash)\u003c\/td\u003e\n\u003ctd\u003e32 Megabytes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNonvolatile Memory\u003c\/td\u003e\n\u003ctd\u003e4 Mbits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExecution Cycle Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 100 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReal-Time Clock Resolution\u003c\/td\u003e\n\u003ctd\u003e1 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e18 VDC to 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power (With Field Power)\u003c\/td\u003e\n\u003ctd\u003eFull Load: 4.6W; Minimum: 1.6W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs (AI)\u003c\/td\u003e\n\u003ctd\u003e8 channels, 4-20mA \/ 1-5VDC, 16-bit resolution, accuracy +-0.1% at 25 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs (AO)\u003c\/td\u003e\n\u003ctd\u003e2 channels, 4-20mA, 12-bit resolution, load resistance 50-600 ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs (DI)\u003c\/td\u003e\n\u003ctd\u003e10 channels, 24VDC (+\/-10%), guaranteed ON at 12VDC, OFF at 4VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Outputs (DO)\u003c\/td\u003e\n\u003ctd\u003e6 channels, 24VDC, 80mA max load per point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse Inputs (PI)\u003c\/td\u003e\n\u003ctd\u003e2 channels, 5-10V peak-to-peak, 0 to 10kHz frequency\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Ports\u003c\/td\u003e\n\u003ctd\u003e2x 10\/100BaseTx RJ45 ports (isolated 1500V RMS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Ports\u003c\/td\u003e\n\u003ctd\u003e2x RS232 (RJ45), 2x RS485 (2-wire half-duplex screw terminal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +75 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN rail (TH35-7.5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e184.0 mm x 98.5 mm x 140.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e700 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Pin\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Input\u003c\/td\u003e\n\u003ctd\u003e18-30 VDC Terminal Connections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRS232 Port A (RJ45)\u003c\/td\u003e\n\u003ctd\u003eTD, RD, CTS, RTS, CD, DTR, DSR\/RI, GND\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRS232 Port B (RJ45)\u003c\/td\u003e\n\u003ctd\u003eTD, RD, CTS, RTS, CD, DTR, DSR\/RI, GND\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRS485 Port C (Screw)\u003c\/td\u003e\n\u003ctd\u003eGND, 485+, 485-, Termination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRS485 Port D (Screw)\u003c\/td\u003e\n\u003ctd\u003eGND, 485+, 485-, Termination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Port 1 (RJ45)\u003c\/td\u003e\n\u003ctd\u003e10\/100BaseTx Network Connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Port 2 (RJ45)\u003c\/td\u003e\n\u003ctd\u003e10\/100BaseTx Network Connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOnboard I\/O Terminals\u003c\/td\u003e\n\u003ctd\u003e28 Mixed Onboard I\/O Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Installation:\u003c\/strong\u003e Mount the assembly securely onto standard TH35-7.5 DIN rail.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply Wiring:\u003c\/strong\u003e Wire an 18 to 30 VDC external power supply to the designated power input terminals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEthernet Cabling:\u003c\/strong\u003e Connect shielded RJ45 Ethernet cables to the network ports; ensure separate subnets are configured when using both ports.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSerial Wiring:\u003c\/strong\u003e Maintain proper termination (120 ohm) for RS485 2-wire half-duplex lines up to a maximum network length of 1200 meters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFlammability: UL 94V-0 materials\u003c\/li\u003e\n\u003cli\u003eEN61010-1:1993; CE\u003c\/li\u003e\n\u003cli\u003eEN61326-1; CE\u003c\/li\u003e\n\u003cli\u003eEN61326\u003c\/li\u003e\n\u003cli\u003eCE Certificate\u003c\/li\u003e\n\u003cli\u003eANSI\/ISA S71.04 Class G2 (Standard)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667763163499,"sku":"SC-PCMX01 51307195-175","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-sc-pcmx01-51307195-175-control-module-efy0qllh5cp_92abfedf-be87-41dd-aa18-9f243e29492e.jpg?v=1765501743"},{"product_id":"honeywell-tk-ffif01-51403420-275-experion-pks-ciom-a-fieldbus-interface-module","title":"Honeywell TK-FFIF01 51403420-275 Experion PKS CIOM-A Fieldbus Interface Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell TK-FFIF01\u003c\/strong\u003e (part number \u003cstrong\u003e51403420-275\u003c\/strong\u003e) is a conformally coated CIOM-A Fieldbus Interface Module (FIM2) designed for the Experion Process Knowledge System (PKS). The \u003cstrong\u003eTK-FFIF01\u003c\/strong\u003e double-width chassis-based module installs directly into an Experion C200 Controller rack or a remote I\/O chassis rack to deliver high-capacity FOUNDATION Fieldbus integration. It supports two (2) H1 Fieldbus networks running at 31.25 kbps, enabling transparent, system-wide access to device data, control signals, diagnostics, and alarms without single points of failure.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDouble slot-width module design compatible with Experion C200 Controller racks and remote I\/O chassis racks.\u003c\/li\u003e\n\u003cli\u003eSupports two (2) H1 FOUNDATION Fieldbus networks operating at 31.25 kbps.\u003c\/li\u003e\n\u003cli\u003eHigh-capacity architecture providing direct integration of data access, control, connections, diagnostics, and alarms.\u003c\/li\u003e\n\u003cli\u003eConformal coating protection for enhanced durability in harsh industrial operating environments.\u003c\/li\u003e\n\u003cli\u003eFull support for Link Active Schedule (LAS) and Backup LAS capabilities to maintain link availability during module disruption or removal.\u003c\/li\u003e\n\u003cli\u003eCompatible with non-redundant and redundant configurations using the Redundancy Module (RM).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eExperion PKS C200 Controller system integration\u003c\/li\u003e\n\u003cli\u003eProcess automation in chemical plants, oil and gas refineries, and offshore\/onshore platforms\u003c\/li\u003e\n\u003cli\u003ePower generation boilers and pilot plant operations\u003c\/li\u003e\n\u003cli\u003ePharmaceutical and advanced manufacturing fieldbus device networks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTK-FFIF01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e51403420-275\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDouble slot-width module (CIOM-A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConformally coated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhysical Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eH1 FOUNDATION Fieldbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of H1 Networks per FIM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 (each running at 31.25 kbps)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Fieldbus Devices per H1 Network\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAvailable Macrocycle Period\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 ms, 500 ms, 1 sec, 2 sec, 4 sec, 8 sec, 16 sec, 32 sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Connection to RTP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTC-FFCxxx Fieldbus RTP Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector \/ Interface\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChassis Slot Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDouble slot-width rack backplane bus connection to C200 Controller or Remote I\/O chassis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRTP Interface Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDedicated connection to Fieldbus Remote Termination Panels via TC-FFCxxx cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eH1 Fieldbus Link 1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePrimary\/Secondary H1 Fieldbus network segment 1 connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eH1 Fieldbus Link 2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePrimary\/Secondary H1 Fieldbus network segment 2 connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack Mounting:\u003c\/strong\u003e Ensure the module is properly aligned and seated into two adjacent chassis slots within the Experion C200 Controller rack or remote I\/O chassis rack.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Routing:\u003c\/strong\u003e Connect the module to the appropriate Remote Termination Panel (RTP) using official TC-FFCxxx series Fieldbus RTP cables (e.g., TC-FFC010, TC-FFC025, TC-FFC050, or TC-FFC100).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding \u0026amp; Shielding:\u003c\/strong\u003e Maintain proper fieldbus cable shielding and system grounding to mitigate EMI\/RFI interference on the 31.25 kbps H1 communication links.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy Setup:\u003c\/strong\u003e For redundant operation, ensure synchronization is configured via the Redundancy Module (RM) according to Experion PKS guidelines.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667764146539,"sku":"TK-FFIF01 51403420-275","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-tk-ffif01-51403420-275-fieldbus-interface-module-5c0oajmlpdu_fc204c22-8b32-4ae1-9147-8307b0c1250e.jpg?v=1765501759"},{"product_id":"honeywell-mc-taih14-51305887-150-experion-pks-high-level-analog-input-hart-fta-module","title":"Honeywell MC-TAIH14 51305887-150 Experion PKS High Level Analog Input HART FTA Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell MC-TAIH14\u003c\/strong\u003e (Part Number: \u003cstrong\u003e51305887-150\u003c\/strong\u003e) is a High Level Analog Input HART Field Termination Assembly (HLAIHART FTA) designed for integration within Honeywell Process Manager (PM), Advanced Process Manager (APM), High Performance Process Manager (HPM), and Experion Process Knowledge System (PKS) I\/O architectures. Acting as the direct physical interface between field-mounted process transmitters and system Input\/Output Processors (IOPs), the assembly channels 16 analog input signals while facilitating pass-through Highway Addressable Remote Transducer (HART) digital communication.\u003c\/p\u003e\n\u003cp\u003eFeaturing a 16-channel architecture with compression-style terminal blocks, the \u003cstrong\u003eMC-TAIH14\u003c\/strong\u003e enables clean termination of 4-20 mA field loops from transmitters measuring pressure, flow, level, and temperature. The board is built on Honeywell Size B mounting dimensions, providing physical layout compatibility for standard cabinet channel mounting alongside adjacent process termination assemblies.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eMC-TAIH14\u003c\/strong\u003e assembly (51305887-150) establishes reliable signal paths for real-time regulatory control loops and asset management functions. By interfacing high-level analog signals directly to system I\/O modules, it simplifies cabinet wiring, shields control room electronics from field-side interference, and provides access points for HART hand-held communicators and asset management software suites.\u003c\/p\u003e\n\u003cp\u003eDesigned for high-density control environments, the board functions seamlessly across redundant and non-redundant system hardware layouts. Its structured terminal arrangement reduces field installation time and ensures long-term operational continuity across continuous process automation plants.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e16-Channel Capacity:\u003c\/strong\u003e Supports up to 16 individual high-level analog input channels for high-density field signal processing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHART Protocol Support:\u003c\/strong\u003e Facilitates simultaneous transmission of standard 4-20 mA analog signals and HART digital communications for smart field instrument diagnostics.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompression Terminal Blocks:\u003c\/strong\u003e Equipped with reliable compression-type (C) wiring terminals to simplify field instrument loop connections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize B Mounting Form Factor:\u003c\/strong\u003e Designed in standard Honeywell Size B dimensions for uniform cabinet layout and channel mounting integration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem IOP Compatibility:\u003c\/strong\u003e Integrates directly with Honeywell High Level Analog Input (HLAI) Processors via standard pre-fabricated I\/O interface cables.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmart Field Transmitter Interfacing:\u003c\/strong\u003e Terminating 4-20 mA HART-enabled pressure, temperature, differential pressure, and level transmitters in process control loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAsset Management Routing:\u003c\/strong\u003e Routing digital HART variables and field device diagnostic parameters to maintenance software systems without interrupting control loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDCS Cabinets Integration:\u003c\/strong\u003e Structuring high-density analog signal wiring within standard Honeywell TPS and Experion Process Knowledge System (PKS) enclosures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExact Model \/ Order Code\u003c\/td\u003e\n\u003ctd\u003eMC-TAIH14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e51305887-150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction \/ Subtype\u003c\/td\u003e\n\u003ctd\u003eHigh Level Analog Input HART FTA (HLAIHART)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Count\u003c\/td\u003e\n\u003ctd\u003e16 Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Type\u003c\/td\u003e\n\u003ctd\u003eCompression Terminals (C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Size\u003c\/td\u003e\n\u003ctd\u003eSize B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Type\u003c\/td\u003e\n\u003ctd\u003e4-20 mA DC \/ HART Digital Communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003eHoneywell Process Manager (PM \/ APM \/ HPM \/ Experion)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eInterface \/ Connection Point\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Compression Terminals\u003c\/td\u003e\n\u003ctd\u003eSecure connection points for 16 individual 4-20 mA HART analog input field loops\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Interface Connector\u003c\/td\u003e\n\u003ctd\u003eMulti-pin header for standard pre-fabricated cable connection to system I\/O Processors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003ePre-Installation Verification:\u003c\/strong\u003e Inspect the assembly part number (MC-TAIH14 \/ 51305887-150) to verify matching model specifications and physical integrity prior to mounting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Snap or latch the Size B assembly into the dedicated FTA mounting channel inside the cabinet enclosure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Isolation:\u003c\/strong\u003e De-energize loop power and field-side circuits before wiring to prevent arc flash or electrical damage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Loop Connection:\u003c\/strong\u003e Connect field instrument wiring to the compression terminals, adhering to polarity markings for each of the 16 analog channels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Interface Cable:\u003c\/strong\u003e Connect the pre-fabricated Honeywell I\/O interface cable between the FTA board connector and the designated IOP slot in the cardfile.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Bonding:\u003c\/strong\u003e Ensure field cable shields are properly grounded according to plant EMC and Honeywell system installation rules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommissioning Checks:\u003c\/strong\u003e Measure loop current on active channels, confirm analog-to-digital signal scaling at the controller, and test HART pass-through communication using a HART communicator.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667764539755,"sku":"MC-TAIH14 51305887-150","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/MC-TAIH14-51305887-150_003_1200x1200_9faa26c2-21c1-46ed-835e-5ca03524e45c.jpg?v=1787715853"},{"product_id":"honeywell-8c-taoxa1-51307135-175-series-8-digital-output-module","title":"Honeywell 8C-TAOXA1 51307135-175 Series 8 Digital Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell 8C-TAOXA1 (model 51307135-175) is a high-density digital output module designed for use within the Honeywell Series 8 distributed control system (DCS) architecture. This hardware component interfaces controller logic directly with plant-floor actuators, solenoid valves, and indicator lamps. Engineered for continuous industrial process control environments, it provides reliable switching signals to execute control strategies safely and predictably.\u003c\/p\u003e\n\u003cp\u003eAs part of the Series 8 I\/O family, the 8C-TAOXA1 integrates directly into standard system mounting infrastructure, communicating with control processors via the internal system bus. Its modular design supports efficient installation and hot-swappable maintenance within compatible control cabinets, minimizing process downtime during system expansions or hardware servicing.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDesigned specifically for integration within the Honeywell Series 8 DCS platform.\u003c\/li\u003e\n  \u003cli\u003eProvides reliable digital output signal switching for industrial actuators and final control elements.\u003c\/li\u003e\n  \u003cli\u003eModular form factor optimized for standard Series 8 I\/O carrier mounting.\u003c\/li\u003e\n  \u003cli\u003eSupports system diagnostics to monitor channel status and hardware health.\u003c\/li\u003e\n  \u003cli\u003eEngineered for operation in standard industrial control room and cabinet environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eContinuous process manufacturing and chemical refining plants.\u003c\/li\u003e\n  \u003cli\u003eOil and gas upstream and downstream automation facilities.\u003c\/li\u003e\n  \u003cli\u003ePower generation and utility distribution systems.\u003c\/li\u003e\n  \u003cli\u003eWater and wastewater treatment plant control architectures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eHoneywell\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Family\u003c\/td\u003e\n      \u003ctd\u003eSeries 8\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eExact Model \/ Part Number\u003c\/td\u003e\n      \u003ctd\u003e8C-TAOXA1 \/ 51307135-175\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003eDigital Output Module\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n      \u003ctd\u003eHoneywell Experion DCS (Series 8 Infrastructure)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMounting Type\u003c\/td\u003e\n      \u003ctd\u003eSeries 8 I\/O Carrier\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCountry of Origin\u003c\/td\u003e\n      \u003ctd\u003eUnited States\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eVerify the part number 8C-TAOXA1 (51307135-175) against system engineering documentation prior to physical placement.\u003c\/li\u003e\n  \u003cli\u003eEnsure all associated power sources and field circuits are de-energized before handling hardware.\u003c\/li\u003e\n  \u003cli\u003eInspect the module connectors and Series 8 I\/O carrier slot for physical damage, debris, or bent pins.\u003c\/li\u003e\n  \u003cli\u003eSecurely mount the module onto the designated slot on the Series 8 carrier, ensuring proper locking mechanisms engage.\u003c\/li\u003e\n  \u003cli\u003eConnect field wiring to the corresponding terminal blocks according to loop diagrams.\u003c\/li\u003e\n  \u003cli\u003eRestore power and verify module health status through the Experion engineering station.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667764703595,"sku":"8C-TAOXA1 51307135-175","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-8c-taoxa1-51307135-175-digital-output-module-h4upxly4yrf_ad5edc1e-5f6a-4b08-8e70-a6cf1e5dfd2d.jpg?v=1765501768"},{"product_id":"honeywell-mc-tamt04-51305890-175-experion-pks-llmux2-thermocouple-field-termination-assembly","title":"Honeywell MC-TAMT04 (51305890-175) Experion PKS LLMUX2 Thermocouple Field Termination Assembly","description":"\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  The \u003cstrong\u003eHoneywell MC-TAMT04\u003c\/strong\u003e (Part Number \u003cstrong\u003e51305890-175\u003c\/strong\u003e) is a high-reliability, 16-channel \u003cstrong\u003eLLMUX2 Thermocouple Field Termination Assembly (FTA)\u003c\/strong\u003e engineered for integration with Honeywell Experion PKS, xPM, and Experion PMIO architectures. Utilizing advanced \u003cstrong\u003esolid-state technology\u003c\/strong\u003e, this module replaces legacy mercury-wetted relays, eliminating environmental hazards while drastically improving loop resistance tolerances to allow longer field thermocouple wiring runs. The assembly is equipped with an integrated local \u003cstrong\u003eCold Junction Reference (CJR)\u003c\/strong\u003e, high-performance compression terminals, a single Input\/Output Processor (IOP) interface, and a robust \u003cstrong\u003econformal coating\u003c\/strong\u003e for continuous duty in harsh, corrosive industrial environments.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-left: 1.5rem; margin-bottom: 1rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePer-Channel Isolation:\u003c\/strong\u003e 16 fully-isolated channels providing robust channel-to-channel, channel-to-PM, and channel-to-power supply common separation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSolid-State Relay Architecture:\u003c\/strong\u003e Replaces traditional mercury-wetted components to provide enhanced stability and long-term operating life.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDedicated A\/D Per Channel:\u003c\/strong\u003e High-performance analog-to-digital conversion circuits per channel ensure precise signal tracking.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFast Open-Thermocouple Detection:\u003c\/strong\u003e Built-in advanced diagnostics identify open-circuit faults within a fixed 1-second interval.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDual-Purpose Design:\u003c\/strong\u003e The same underlying 51305890-175 hardware handles both local and remote cold junction tracking through an on-board jumper configuration.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCorrosive Environment Protection:\u003c\/strong\u003e Factory conformally coated to meet stringent industrial atmospheric standards and maintain CE compliance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-left: 1.5rem; margin-bottom: 1rem;\"\u003e\n  \u003cli\u003eExperion PKS distributed control systems (DCS) process monitoring.\u003c\/li\u003e\n  \u003cli\u003eHigh-density temperature acquisition loops in hydrocarbon processing and petrochemical facilities.\u003c\/li\u003e\n  \u003cli\u003eThermal monitoring and profiling inside gas turbines, boilers, and heavy industrial furnaces.\u003c\/li\u003e\n  \u003cli\u003eCorrosive chemical processing plants requiring conformally coated process interface equipment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eTechnical Specifications Table\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d; text-align: left;\"\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eSpecification\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eHoneywell\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eMC-TAMT04\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eBase FTA Part Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e51305890-175\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eInput Channels\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e16 channels (fully-isolated)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eInput Scan Rate\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e1 Second fixed by IOLP\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eChannel Bandwidth\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e0 to 4.7 Hz (-3 dB)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eNominal Input Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e-20 to +100 millivolts\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eMaximum Input (Non-Damaging)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e-10 to +10 volts continuous\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eGain Error\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e0.050% full scale maximum (-20 to +100 millivolt range)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eResolution of Reading\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e2 microvolt per bit\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eTemperature Stability\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e+\/-20 ppm per degC maximum\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eLong Term Drift\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e500 ppm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eInput Impedance\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e1 megohm at dc\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eCommon Mode Voltage (CMV)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e+\/-250 Vdc or Vac rms (channel-to-channel and channel-to-PM common)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eCMRR (50 or 60 Hz)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e120 dB minimum (with 1000 ohms source impedance maximum)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eNMRR (50 or 60 Hz)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e60 dB minimum\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eSupported Thermocouple Types\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eType J (-200 to +1200 Celsius), Type K (-100 to +1370 Celsius), Type E (-200 to +1000 Celsius), Type T (-230 to +400 Celsius), Type B (+100 to +1820 Celsius), Type S (0 to +1700 Celsius), Type R (0 to +1700 Celsius), Japan Type R' (0 to +1770 Celsius)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eCold Junction Compensation Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e-20 to +60 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eCJR Compensation Accuracy\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e+\/-0.5 degC typical\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eSurge Protection\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eIEEE SWC 472-1974 certified at sensor terminals\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003ePower Dissipation\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e2.25 watts maximum\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eThermal Dissipation\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e7.68 Btu per hour maximum\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eSupply Voltage Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e15 to 30 Vdc (24 Vdc nominal)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eSupply Current\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e160 milliamps at 15 Vdc\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eOperating Environmental Limits\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e0 to 50 degC; 10 to 90% non-condensing relative humidity (derated to max 40 degC)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eStorage Environmental Limits\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e-40 to 80 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eAgency Certifications\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eCSA Certified Class 1, Division 2, Groups A, B, C, D; UL listed; CE Compliant\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eDimensions (H x W x D)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e307.34 mm L x 124.46 mm W x 63.5 mm D (12.1 x 4.9 x 2.5 inches)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eUnited States\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e1.25 kg (2.75 lbs)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e360 mm x 180 mm x 100 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  The \u003cstrong\u003eMC-TAMT04\u003c\/strong\u003e serves as a direct form, fit, and functional replacement for legacy, obsolete \u003cstrong\u003eLLMUX TC FTA\u003c\/strong\u003e variants. It seamlessly replaces non-CE compliant boards \u003cstrong\u003eMU-TAMT02\u003c\/strong\u003e (51401491-100) and \u003cstrong\u003eMC-TAMT02\u003c\/strong\u003e (51401491-150), alongside older CE-compliant models \u003cstrong\u003eMU-TAMT03\u003c\/strong\u003e (51309223-125) and \u003cstrong\u003eMC-TAMT03\u003c\/strong\u003e (51309223-175). Notably, the base board assembly (51305890-175) is identical to the one used in the remote cold junction reference model, \u003cstrong\u003eMC-TAMT14\u003c\/strong\u003e. \n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  When evaluating field thermocouple loop resistances, the solid-state architecture of the LLMUX2 provides an expanded loop driving capability compared to old mercury systems, enabling longer field cable boundaries without signaling loss. However, engineers must carefully manage enclosure thermal metrics. The assembly dissipates up to 2.25 watts continuously, yielding a heat load of 7.68 Btu per hour. Ensure proper panel venting if multiple assemblies are grouped in dense Marshalling racks to avoid crossing the maximum 40 degC operational limit under high-humidity environments.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  The unit utilizes a 6-pin compression plug for connection at the J6 port located at the top of the board assembly. If upgrading an older non-CE legacy cabinet setup that features a 4-pin plug, the internal wires must be extracted and reworked into the 6-pin connector provided in the MC-TAMT04 shipping container. Additionally, ensure the address jumper designated as \u003cstrong\u003e\"UNIT\"\u003c\/strong\u003e is set correctly to '0' or '1' to mirror the address scheme of the existing system before connecting the 50-pin J1 cable interface to the Power Adapter.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem; color: #9b2c2c;\"\u003e\n  \u003cstrong\u003eCRITICAL WARNING:\u003c\/strong\u003e RISK OF ELECTRICAL SHOCK. Up to 250 Volts AC RMS or Vdc common mode voltage may be present underneath the primary protective plastic cover arising from external field process instrumentation loops. Disconnect all process control loop power and ensure proper lock-out\/tag-out safety boundaries are fully enforced before removing the board cover or loosening field terminal connections.\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem;\"\u003e1\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eRecord the PV measurements of all active process loops from the central operations console to ensure validation benchmarks are available post-installation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem;\"\u003e2\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eUnplug the primary 50-pin ribbon connector (J1) at the Power Adapter to fully decouple the LLMUX IOP from the local link system.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem;\"\u003e3\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eLoosen the retention screws on 8-pin terminal plug headers J1, J2, J3, and J4 to slide them away from the assembly without disconnecting field wiring leads.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem;\"\u003e4\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eVerify that the \u003cstrong\u003eJMP2\u003c\/strong\u003e jumper is set to the \u003cstrong\u003e'LOC'\u003c\/strong\u003e position on the replacement card to correctly engage the on-board Local Cold Junction Reference sensor circuit.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem;\"\u003e5\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eMount the board into the standard enclosure tracking channel, secure the 4 corner retention standoffs, re-engage terminal headers, and reinstall the plastic safety cover.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667764965739,"sku":"MC-TAMT04 51305890-175","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-mc-tamt04-51305890-175-thermocouple-input-terminal-board-1tiw0igfs15_625e33fd-73fe-437e-8795-1f61a6f07871.jpg?v=1765501771"},{"product_id":"honeywell-cc-paox01-51405039-275-series-c-analog-output-module","title":"Honeywell CC-PAOX01 51405039-275 Series C Analog Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell CC-PAOX01 51405039-275\u003c\/strong\u003e is an Analog Output module with non-HART functionality designed for process control applications. The \u003cstrong\u003eHoneywell CC-PAOX01\u003c\/strong\u003e provides analog output signal conditioning and control capability, operating within Honeywell Experion C300 systems. It interfaces directly with field devices and marshalling systems via supported Input Output Termination Assemblies (IOTAs), including \u003ca href=\"https:\/\/www.plcprotech.com\/products\/honeywell-cc-taox01-51308351-175-experion-pks-analog-output-iota\"\u003e\u003cstrong\u003eCC-TAOX01\u003c\/strong\u003e\u003c\/a\u003e and \u003ca href=\"https:\/\/www.plcprotech.com\/products\/honeywell-cc-taox11-51308353-175-experion-c300-analog-output-iota\"\u003e\u003cstrong\u003eCC-TAOX11\u003c\/strong\u003e\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalog Output functionality\u003c\/strong\u003e: Provides non-HART analog output channel interfaces for industrial process automation systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Integration\u003c\/strong\u003e: Compatible with standard Experion Series C IOTA assemblies, including \u003cstrong\u003eCC-TAOX01\u003c\/strong\u003e and \u003cstrong\u003eCC-TAOX11\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarshalling Support\u003c\/strong\u003e: Interfaces with Honeywell Universal Signal Conditioning Assemblies (\u003cstrong\u003eCC-USCA01\u003c\/strong\u003e) and Universal Integrated FTAs (\u003cstrong\u003eCC-UGIA01\u003c\/strong\u003e) via Mass Termination Cables (MTC).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Conditioning Options\u003c\/strong\u003e: Supports signal routing through Universal Pass Through Adapters (\u003cstrong\u003eCC-UPTA01\u003c\/strong\u003e), Analog Output Barriers (\u003cstrong\u003eCC-UGAO01\u003c\/strong\u003e), and Analog Output Isolators (\u003cstrong\u003eCC-UAOA01\u003c\/strong\u003e).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProcess automation output control\u003c\/li\u003e\n\u003cli\u003eField device and valve positioner actuation via non-HART analog signals\u003c\/li\u003e\n\u003cli\u003eCentralized and distributed marshalling cabinet installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCC-PAOX01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e51405039-275\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAnalog Output with non-HART\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIOM Block Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupported IOTAs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCC-TAOX01, CC-TAOX11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupported Universal Marshalling Hardware\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCC-USCA01, CC-UGIA01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Signal Conditioning Modules\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCC-UPTA01, CC-UGAO01, CC-UAOA01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIOTA Mounting\u003c\/strong\u003e: Mount the module onto compatible IOTA assemblies (\u003cstrong\u003eCC-TAOX01\u003c\/strong\u003e or \u003cstrong\u003eCC-TAOX11\u003c\/strong\u003e) inside the cabinet enclosure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring\u003c\/strong\u003e: When interfacing through the Signal Conditioning Assembly (SCA), connect via Mass Termination Cable (MTC) to the FTA DSUB connector.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrostatic Discharge (ESD)\u003c\/strong\u003e: Observe proper ESD precautions before handling components; wear an approved wrist-strap grounding device and avoid touching connector pins or circuit components.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667765096811,"sku":"CC-PAOX01 51405039-275","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/CC-PAOX01-51405039-275_001_1200x1200_ed349d34-8218-4fae-b98a-bfd73d347351.jpg?v=1786538683"},{"product_id":"honeywell-tk-prr021-51309288-475-experion-series-a-redundancy-module","title":"Honeywell TK-PRR021 51309288-475 Experion Series A Redundancy Module","description":"\u003cp\u003e\u003cb\u003eHoneywell TK-PRR021 51309288-475\u003c\/b\u003e is a double-wide redundancy module designed for the \u003cb\u003eExperion Chassis Series-A\u003c\/b\u003e (CIOM-A) platform to support \u003cb\u003eC200\u003c\/b\u003e control processor redundancy configurations. Operating within \u003cb\u003eExperion LS\u003c\/b\u003e and \u003cb\u003eExperion PKS\u003c\/b\u003e process control architectures, the \u003cb\u003eTK-PRR021\u003c\/b\u003e facilitates synchronized, fault-tolerant operation between dual controller chassis.\u003c\/p\u003e\n\u003cp\u003eEquipped with factory-applied conformal coating, \u003cb\u003eHoneywell TK-PRR021\u003c\/b\u003e provides corrosion protection in environments rated Moderate (G2) or Harsh (G3) per ANSI\/ISA-S71.04-1985 standards. The module occupies two chassis slot positions and draws power directly from internal backplane voltage rails to maintain continuous high availability in industrial process applications.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eConformal coating protection for harsh industrial environments with airborne contaminants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDouble-wide form factor occupying two chassis slot positions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDirect backplane integration for C200 control processor redundancy support\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLow-power internal backplane draw across 24 VDC, 5 VDC, 3.3 VDC, and 1.2 VDC rails\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-availability DCS and PLC control loops\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRedundant C200 control processor systems in Experion PKS and Experion LS platforms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProcess automation environments exposed to corrosive atmospheres\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTK-PRR021\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePart \/ Assembly Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e51309288-475\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModule Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRedundancy Module (RM)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Series\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eExperion Chassis Series-A (CIOM-A)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eChassis Slots Required\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 (Double-wide form factor)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConformal Coating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes (TK designation)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBackplane Current Draw (24 VDC)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.090 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBackplane Current Draw (5 VDC)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.000 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBackplane Current Draw (3.3 VDC)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.750 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBackplane Current Draw (1.2 VDC)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.007 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 60 degC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStorage Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to 85 degC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRelative Humidity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 to 95% noncondensing (derated to 55% above 40 degC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAltitude Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-300 to +3000 m\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVibration (Operating\/Storage)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 to 60 Hz, 0.5 g max\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVibration (Transportation)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 to 60 Hz, 1.0 g max\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMechanical Shock (Operating\/Storage)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 g max, 30 ms max duration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMechanical Shock (Transportation)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20 g max, 30 ms max duration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eChassis Mounting\u003c\/b\u003e: Insert the module into two adjacent chassis slot positions in a compatible Series-A chassis (4, 7, 10, 13, or 17-slot chassis). Ensure total backplane power limits are maintained.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eCabinet Clearance\u003c\/b\u003e: Maintain a minimum vertical distance of 15.2 cm (6.0 in) and horizontal distance of 10.2 cm (4.0 in) between chassis and enclosure walls for heat dissipation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eRemoval and Insertion Under Power (RIUP)\u003c\/b\u003e: Permitted only when installed in ordinary, non-hazardous locations. RIUP is strictly prohibited in Class I, Division 2 hazardous locations without a hot work permit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eEnvironmental Protection\u003c\/b\u003e: Enclose the assembly within a NEMA 4 or NEMA 12 panel when required by local codes or operational standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eUL\u003c\/b\u003e: UL 508 Industrial Control Equipment Listed\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eCSA\u003c\/b\u003e: Class I, Division 2, Groups A, B, C \u0026amp; D Hazardous and Ordinary Locations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eFM\u003c\/b\u003e: Approved for Class I, Division 2 Hazardous Locations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eCE Mark\u003c\/b\u003e: Complies with EMC Directive 89\/336\/EEC, EN 50081-2 (Emissions), and EN 50082-2 (Immunity)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eC-Tick\u003c\/b\u003e: Meets Australian Radiocommunications Act 1992 Section 182 EMC requirements\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667765653867,"sku":"TK-PRR021 51309288-475","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-tk-prr021-51309288-475-redundancy-module-dzikzwtbyy3_92eda2ac-7d72-4e76-a79c-0cf96a157a86.jpg?v=1765505431"},{"product_id":"honeywell-cc-tdi230-series-c-digital-input-module","title":"Honeywell CC-TDI230 Series C Digital Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell CC-TDI230 is a high-density digital input module designed for deployment within the Experion PKS Series C distributed control system architecture. This module provides reliable monitoring of discrete industrial field devices, accepting multiple high-voltage AC and DC input signals to interface standard on\/off plant equipment directly with the control network.\u003c\/p\u003e\n\u003cp\u003eEngineered for demanding industrial process environments, the CC-TDI230 incorporates comprehensive channel isolation to protect sensitive internal system electronics from external electrical transients, ground loops, and high-voltage surges. Its physical footprint and terminal allocation are specifically optimized for Series C I\/O Termination Assemblies (IOTAs), streamlining cabinet layout and reducing overall installation time.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e32 discrete input channels supporting high-voltage industrial signal standards.\u003c\/li\u003e\n  \u003cli\u003eDesigned natively for integration with the Honeywell Experion Series C platform and associated IOTA infrastructure.\u003c\/li\u003e\n  \u003cli\u003eRobust optical channel-to-channel and channel-to-ground electrical isolation.\u003c\/li\u003e\n  \u003cli\u003eHigh-density packaging minimizes required cabinet footprint and wiring complexity.\u003c\/li\u003e\n  \u003cli\u003eComprehensive onboard diagnostics for loop status and hardware health monitoring.\u003c\/li\u003e\n  \u003cli\u003eHot-swappable module design permits replacement without interrupting controller operation or process control.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eContinuous process manufacturing plants and refineries.\u003c\/li\u003e\n  \u003cli\u003ePower generation turbine and auxiliary system monitoring.\u003c\/li\u003e\n  \u003cli\u003eOil and gas upstream and downstream automation infrastructure.\u003c\/li\u003e\n  \u003cli\u003eChemical processing and specialty material handling systems.\u003c\/li\u003e\n  \u003cli\u003eDiscrete status tracking for valves, pumps, circuit breakers, and limit switches.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eGeneral Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eHoneywell\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Series\u003c\/td\u003e\n      \u003ctd\u003eExperion Series C\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModel \/ Part Number\u003c\/td\u003e\n      \u003ctd\u003eCC-TDI230\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModule Type\u003c\/td\u003e\n      \u003ctd\u003eDigital Input Module (High Voltage AC\/DC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCountry of Origin\u003c\/td\u003e\n      \u003ctd\u003eUnited States\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eElectrical Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNumber of Channels\u003c\/td\u003e\n      \u003ctd\u003e32 channels\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n      \u003ctd\u003e120V AC \/ 125V DC \/ 240V AC nominal\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eIsolation Rating\u003c\/td\u003e\n      \u003ctd\u003e1500 VAC RMS or VDC optical galvanic isolation\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eMechanical \u0026amp; Environmental\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMounting Type\u003c\/td\u003e\n      \u003ctd\u003eSeries C IOTA (I\/O Termination Assembly)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eApproximate Net Weight\u003c\/td\u003e\n      \u003ctd\u003e0.4 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eApproximate Dimensions\u003c\/td\u003e\n      \u003ctd\u003e7.0 cm x 14.0 cm x 14.5 cm\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eVerify that the part number CC-TDI230 and the corresponding Series C IOTA match your system engineering design drawings.\u003c\/li\u003e\n  \u003cli\u003eEnsure the target IOTA slot is completely de-energized and free of hazardous voltages before handling hardware.\u003c\/li\u003e\n  \u003cli\u003eInspect the module connector pins and IOTA socket for any physical damage, bending, or foreign particulate contamination.\u003c\/li\u003e\n  \u003cli\u003eAlign the module carefully with the guide tracks on the Series C carrier and push evenly until firmly seated.\u003c\/li\u003e\n  \u003cli\u003eSecure the module using any integrated mechanical locking latches or retention screws.\u003c\/li\u003e\n  \u003cli\u003eRestore system power and confirm through Experion Quick Builder or monitoring software that the module is recognized and communicating without error.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDesigned to meet major industrial safety and electromagnetic compatibility standards associated with Experion Series C hardware.\u003c\/li\u003e\n  \u003cli\u003eRoHS compliant construction.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667984380267,"sku":"CC-TDI230","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-cc-tdi230-analog-input-module-c13fgbxhveu_9100ba01-1dd1-4116-bbc4-3b3b7f626151.jpg?v=1765504822"},{"product_id":"honeywell-cc-sdor01-51308380-175-experion-series-c-digital-output-relay-extension-module","title":"Honeywell CC-SDOR01 51308380-175 Experion Series C Digital Output Relay Extension Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell CC-SDOR01 (Part Number: 51308380-175)\u003c\/strong\u003e is a Digital Output Relay Extension Module engineered for the Experion Series C architecture. Designed to expand output contact capabilities, the module works in conjunction with the \u003cstrong\u003eCC-PDOB01\u003c\/strong\u003e Digital Output Input Output Module (IOM) and the corresponding \u003cstrong\u003eCC-TDOR01\u003c\/strong\u003e or \u003cstrong\u003eCC-TDOR11\u003c\/strong\u003e Relay Input Output Termination Assemblies (IOTAs). By interfacing with the 24 VDC bussed digital output driver electronics, the CC-SDOR01 allows process control systems to drive discrete high-power or low-power loads through isolated dry contact circuits.\u003c\/p\u003e\n\u003cp\u003eBuilt with a 12-inch footprint, the \u003cstrong\u003eHoneywell CC-SDOR01\u003c\/strong\u003e extension assembly provides 32 isolated relay channels that accept user-configured Form-A (SPST\/NO) or Form-B (SPST\/NC) field contact arrangements via jumper settings. This extension board eliminates the need for external interposing relay panels, providing direct dry contact isolation between control logic and field machinery. Each output channel is equipped with socketed relays, LED status indication, and integrated counter-EMF snubbing networks to protect against inductive switching transients.\u003c\/p\u003e\n\u003cp\u003eOperating within the Series C physical layout, the \u003cstrong\u003eCC-SDOR01\u003c\/strong\u003e features vertical mounting, a tilted thermal dissipation design, and detachable two-level field terminal blocks. The module accepts field wiring up to 12 AWG (2.5 mm sq stranded wire) and maintains galvanic isolation of 1500 VAC RMS or +\/-1500 VDC between individual channels and system logic common.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e32 Isolated Relay Channels:\u003c\/strong\u003e Provides 32 dry contact outputs for high-voltage, high-current, or low-voltage switching tasks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfigurable Contact Operation:\u003c\/strong\u003e Supports Form-A (Normally Open) or Form-B (Normally Closed) contact configurations selected via jumpers on a per-channel basis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Switching Capacity:\u003c\/strong\u003e Accommodates steady-state load currents up to 3 A at 250 VAC RMS or 30 VDC, and inrush currents up to 10 A.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSocketed Relay Design:\u003c\/strong\u003e Individual socketed relays allow straightforward field maintenance and channel replacement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-in Transient Suppression:\u003c\/strong\u003e Integrated counter-EMF snubbing circuits (120 Ohm + 0.033 uF) protect contacts from inductive kickback.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGalvanic Isolation:\u003c\/strong\u003e Offers 1500 VAC RMS or +\/-1500 VDC isolation between channels and system logic common.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVisual Diagnostics:\u003c\/strong\u003e Dedicated LED indicators per channel display active output status.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetachable Terminal Blocks:\u003c\/strong\u003e Accepts up to 12 AWG \/ 2.5 mm sq stranded wiring to simplify field landing and cabinet maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterposing Relay Isolation:\u003c\/strong\u003e Direct switching of high-voltage field devices, solenoids, and motor starters without external interposing relay racks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiscrete Process Control:\u003c\/strong\u003e Interfacing Experion C300 control logic with pumps, valves, fans, and annunciator panels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety System Interfacing:\u003c\/strong\u003e Providing volt-free contact signals to third-party safety shutdown systems, motor control centers (MCC), and package units.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMixed Voltage Load Control:\u003c\/strong\u003e Driving combinations of 24 VDC, 120 VAC, and 230 VAC field circuits from a single output assembly.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003eExperion Series C I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCC-SDOR01 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePWA\u003c\/td\u003e\n\u003ctd\u003e51308380-175 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Output Relay Extension Module \/ Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssociated IOM Model\u003c\/td\u003e\n\u003ctd\u003eCC-PDOB01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssociated IOTA Models\u003c\/td\u003e\n\u003ctd\u003eCC-TDOR01, CC-TDOR11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBoard Size\u003c\/td\u003e\n\u003ctd\u003e12 inches (304 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eOutput Capabilities\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e32 isolated contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Form\u003c\/td\u003e\n\u003ctd\u003eForm-A (SPST\/NO) or Form-B (SPST\/NC), jumper selectable per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Material\u003c\/td\u003e\n\u003ctd\u003eAgSnO2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Load Voltage\u003c\/td\u003e\n\u003ctd\u003e250 VAC RMS \/ 125 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Load Voltage\u003c\/td\u003e\n\u003ctd\u003e12 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Load Current\u003c\/td\u003e\n\u003ctd\u003e100 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current (Max)\u003c\/td\u003e\n\u003ctd\u003e10 A for 4 s at 10% duty cycle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTurn-On Time\u003c\/td\u003e\n\u003ctd\u003e20 ms maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTurn-Off Time\u003c\/td\u003e\n\u003ctd\u003e20 ms maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eLoad Ratings (Resistive \u0026amp; Inductive)\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSteady State Rating (250 VAC \/ 125 VAC Resistive)\u003c\/td\u003e\n\u003ctd\u003e3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSteady State Rating (30 VDC Resistive)\u003c\/td\u003e\n\u003ctd\u003e3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSteady State Rating (48 VDC Resistive)\u003c\/td\u003e\n\u003ctd\u003e1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSteady State Rating (125 VDC Resistive)\u003c\/td\u003e\n\u003ctd\u003e0.2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInductive Rating (125\/250 VAC, PF = 0.4)\u003c\/td\u003e\n\u003ctd\u003e2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInductive Rating (30 VAC, L\/R = 100 ms)\u003c\/td\u003e\n\u003ctd\u003e1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInductive Rating (48 VAC, L\/R = 100 ms)\u003c\/td\u003e\n\u003ctd\u003e0.3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInductive Rating (125 VAC, L\/R = 100 ms)\u003c\/td\u003e\n\u003ctd\u003e0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eIsolation \u0026amp; Protection\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e1500 VAC RMS or +\/-1500 VDC (channel-to-channel and channel-to-logic common)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Surge Protection\u003c\/td\u003e\n\u003ctd\u003eIntegrated RC snubber network (120 Ohm + 0.033 uF per channel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Contact Life\u003c\/td\u003e\n\u003ctd\u003e5,000,000 cycles (at 180 cycles\/min)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Contact Life\u003c\/td\u003e\n\u003ctd\u003e50,000 cycles at 6 A (at 6 cycles\/min)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eWiring \u0026amp; Physical\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Terminal Wire Size\u003c\/td\u003e\n\u003ctd\u003eUp to 12 AWG (2.5 mm sq stranded wire)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Display\u003c\/td\u003e\n\u003ctd\u003eChannel ON LED indication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Orientation\u003c\/td\u003e\n\u003ctd\u003eVertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Pre-Installation Verification:\u003c\/strong\u003e Disconnect system logic power and field excitation power sources prior to mounting or servicing the module. Verify that load voltage and current ratings fall within specified thresholds (12 VDC to 250 VAC RMS).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Secure the CC-SDOR01 extension assembly vertically onto the cabinet carrier channels. Maintain proper vertical clearance to allow heat dissipation via natural convection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterconnection Setup:\u003c\/strong\u003e Connect the extension assembly to the primary Digital Output Relay IOTA (CC-TDOR01 or CC-TDOR11) housing the CC-PDOB01 IOM using the dedicated system ribbon cabling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel Contact Configuration:\u003c\/strong\u003e Set the channel jumper headers for each of the 32 outputs to select either Form-A (Normally Open) or Form-B (Normally Closed) dry contact functionality based on control loop requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Wiring Termination:\u003c\/strong\u003e Strip field conductor ends and secure them into the detachable terminal blocks. Ensure wire gauges do not exceed 12 AWG (2.5 mm sq). Route field cables through top or bottom cabinet wireways.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePre-Power Inspection:\u003c\/strong\u003e Check that all terminal plugs are seated firmly, jumpers are correctly placed, and shield\/protective earth grounds are connected.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eConfiguration and Maintenance Recommendations\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFail-Safe Behavior (FAILOPT):\u003c\/strong\u003e Configure channel fail-safe options via Experion control software. In the event of an IOM communication loss or system hardware fault, individual channels can be programmed to hold their last state or shed to a safe zero condition.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelay Servicing:\u003c\/strong\u003e The socketed relay design allows for individual relay replacement. When replacing socketed units, use matching AgSnO2 contact assemblies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact Life Management:\u003c\/strong\u003e For highly inductive loads, confirm that inductive derating factors (such as PF = 0.4 or L\/R = 100 ms) are respected to maintain contact longevity over the rated 50,000 electrical operations.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667986608491,"sku":"CC-SDOR01 51308380-175","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/CC-SDOR01-51308380-175_001_1200x1200_8ed13457-c1f9-44b1-b807-103230e2a43f.webp?v=1787723603"},{"product_id":"honeywell-tp-dsoep1-100-desk-operator-entry-panel","title":"Honeywell TP-DSOEP1-100 Desk Operator Entry Panel","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell TP-DSOEP1-100\u003c\/strong\u003e is a desk operator entry panel designed to interface directly with Honeywell Excel series automation systems. It functions as a dedicated operator interface, facilitating direct control access, monitoring, and parameter entry across interconnected control units.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eTP-DSOEP1-100\u003c\/strong\u003e enables direct operational access to several Honeywell Excel controller models, including Excel 50, Excel 100, Excel 500, Excel 500-XCL5010 (with XI582, only), Excel 600, and Excel 800. It provides reliable operator interaction for daily facility management and automation oversight.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDirect operator entry panel interface for Honeywell controller systems\u003c\/li\u003e\n\u003cli\u003eDesigned for desk placement and local operator interaction\u003c\/li\u003e\n\u003cli\u003eEnables parameter input and monitoring capabilities\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHoneywell Excel controller network monitoring and parameter access\u003c\/li\u003e\n\u003cli\u003eFacility management and building automation control operator interfacing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003eTP-DSOEP1-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Description\u003c\/td\u003e\n\u003ctd\u003eDESK OPERATOR ENTRY PANEL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003eTP-DSOEP1-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDesk Operator Entry Panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Controller Models\u003c\/td\u003e\n\u003ctd\u003eExcel 50, Excel 100, Excel 500, Excel 500-XCL5010 (with XI582 only), Excel 600, Excel 800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Position the desk panel on a stable surface near the operator station, ensuring clear visual access and comfortable ergonomics.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnections:\u003c\/strong\u003e Securely connect the communication interface cabling between the entry panel and the designated Honeywell Excel controller port.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHandling:\u003c\/strong\u003e Apply standard electrostatic discharge (ESD) protection procedures during cable installation and terminal connections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerification:\u003c\/strong\u003e Verify signal connectivity and power status prior to performing controller parameter entry or system configuration tasks.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667989557611,"sku":"TP-DSOEP1-100","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-tp-dsoep1-100-enhanced-operator-keyboard-nrittewo0pd_381729c1-c521-4213-9b7f-c455a1d243fa.jpg?v=1765504880"},{"product_id":"honeywell-900b16-0001-controledge-hc900-16-slot-i-o-chassis","title":"Honeywell 900B16-0001 ControlEdge HC900 16-Slot I\/O Chassis","description":"\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e900B16-0001 (900B16-0001)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-capacity 16-slot I\/O rack designed for the Honeywell ControlEdge HC900 Process \u0026amp; Safety Controller system. This chassis serves as the physical and communication backbone for various HC900 I\/O modules, including analog inputs\/outputs and digital inputs\/outputs. Engineered for modularity and scalability, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e900B16-0001\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports both standard process control and SIL 2 safety-related applications, providing a ruggedized mounting platform with integrated power distribution and backplane communications.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e900B16-0001\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eControlEdge HC900 \/ Series 900\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal I\/O Slots\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 Slots (for I\/O modules)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eReserved Slots\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDedicated slots for Power Supply and Scanner\/CPU\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Power\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDistributed 5V and 24V from Power Supply Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePanel Mount (Internal Cabinet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSafety Integrity Level\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSIL 2 Certified (when used with appropriate modules)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 °C to 60 °C (32 °F to 140 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIndustrial-grade aluminum\/steel hybrid\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh-speed internal bus for I\/O scanning\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eStructural Capabilities\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e900B16-0001\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed to maximize I\/O density within a single rack footprint. It facilitates the \"hot-swap\" capability of the HC900 system, allowing modules to be replaced while the rest of the rack remains powered and operational. The chassis includes integrated grounding points and terminal block connectors for the power supply, ensuring clean power delivery to sensitive analog instrumentation. It is a critical component for large-scale boiler control, thermal processing, and water treatment applications.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQs\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this chassis include the Power Supply or CPU?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e900B16-0001\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis the empty 16-slot rack frame. The Power Supply (e.g., 900P01) and the CPU or Scanner module must be purchased and installed separately.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I mix safety and non-safety modules in this rack?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the HC900 architecture allows for the coexistence of non-safety and safety-critical I\/O within the same chassis, provided the system configuration adheres to the Honeywell Safety Manual guidelines.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667990147435,"sku":"900B16-0001","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-900b16-0001-plc-module-s1z4in1e0wu_03d48335-7db6-4543-a6e4-e6c67c76b1f5.jpg?v=1765504887"},{"product_id":"honeywell-fc-iochas-0003s-safety-manager-redundant-i-o-chassis","title":"Honeywell FC-IOCHAS-0003S Safety Manager Redundant I\/O Chassis","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell FC-IOCHAS-0003S is a specialized redundant I\/O chassis engineered for high-availability industrial safety and control environments. Operating within the Honeywell Safety Manager architecture, this hardware platform provides secure backplane routing and mechanical housing to support fault-tolerant, redundant input and output module configurations. It plays a critical role in maintaining continuous process visibility and system availability by facilitating hot-swappable module operation and uninterrupted signal pathways.\u003c\/p\u003e\n\u003cp\u003eDesigned for mission-critical automation tasks, the chassis integrates cleanly into distributed control and safety-instrumented systems. It distributes power and communication signals reliably to connected I\/O cards, helping facilities minimize downtime during maintenance or primary component faults in heavy industrial process plants.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eEngineered specifically for Honeywell Safety Manager system architectures\u003c\/li\u003e\n  \u003cli\u003eSupports redundant I\/O module pairings for high-availability fault tolerance\u003c\/li\u003e\n  \u003cli\u003eRobust backplane design for secure module retention and reliable signal bus routing\u003c\/li\u003e\n  \u003cli\u003eBuilt for standard industrial cabinet mounting and structured panel layouts\u003c\/li\u003e\n  \u003cli\u003eFacilitates hot-standby module swapping to reduce operational downtime\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eEmergency Shutdown Systems (ESD)\u003c\/li\u003e\n  \u003cli\u003eCritical process safety monitoring\u003c\/li\u003e\n  \u003cli\u003eOil and gas production and refining facilities\u003c\/li\u003e\n  \u003cli\u003eChemical and petrochemical processing plants\u003c\/li\u003e\n  \u003cli\u003ePower generation safety automation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eHoneywell\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Model\u003c\/td\u003e\n      \u003ctd\u003eFC-IOCHAS-0003S\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003eRedundant I\/O Chassis\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSystem Family\u003c\/td\u003e\n      \u003ctd\u003eSafety Manager\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMounting Type\u003c\/td\u003e\n      \u003ctd\u003eDIN Rail or Panel Mount (System Cabinet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd\u003e-20 Celsius to +55 Celsius\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStorage Temperature\u003c\/td\u003e\n      \u003ctd\u003e-40 Celsius to +85 Celsius\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Humidity\u003c\/td\u003e\n      \u003ctd\u003e5% to 95% RH (non-condensing)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCountry of Origin\u003c\/td\u003e\n      \u003ctd\u003eUSA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNet Weight\u003c\/td\u003e\n      \u003ctd\u003e5.6 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDimensions\u003c\/td\u003e\n      \u003ctd\u003e34 cm x 18.8 cm x 6.5 cm\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eVerify the part number and inspect the chassis for any physical damage sustained during transit.\u003c\/li\u003e\n  \u003cli\u003eEnsure all associated power sources and control bus feeds to the target rack are completely de-energized before beginning mechanical installation.\u003c\/li\u003e\n  \u003cli\u003eMount the FC-IOCHAS-0003S securely into the designated control cabinet slot using appropriate fastening hardware.\u003c\/li\u003e\n  \u003cli\u003eConnect system ground wires to the designated earth stud to maintain EMC compliance and electrical safety.\u003c\/li\u003e\n  \u003cli\u003eInsert the designated redundant I\/O modules into the chassis slots, ensuring proper backplane pin alignment and secure latching.\u003c\/li\u003e\n  \u003cli\u003eRe-energize the system power supplies and verify proper status LED indicators on the installed modules before initiating software commissioning.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667990507883,"sku":"FC-IOCHAS-0003S","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-fc-iochas-0003s-redundant-i-o-module-r2ib2tpeb3u_3ab24ec6-289e-48a7-b27d-21c37e9846f2.jpg?v=1765504891"},{"product_id":"honeywell-mc-ghao11-51309540-175-totalplant-solution-galvanically-isolated-analog-output-fta","title":"Honeywell MC-GHAO11 51309540-175 TotalPlant Solution Galvanically Isolated Analog Output FTA","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell MC-GHAO11 51309540-175\u003c\/strong\u003e is a 16-channel galvanically isolated, intrinsically safe Field Termination Assembly (GI\/IS FTA) designed for analog output signal processing within Honeywell TotalPlant Solution (TPS) control systems. Working in tandem with the \u003cstrong\u003eHoneywell MC-PAOY22\u003c\/strong\u003e or \u003cstrong\u003eMU-PAOY22\u003c\/strong\u003e 16-point Analog Output Input\/Output Processor (IOP), this module routes 4-20 mA control signals from Process Manager (PM), Advanced Process Manager (APM), High Performance Process Manager (HPM), and Enhanced High Performance Process Manager (EHPM) controllers to field actuators, control valves, and positioners operating in hazardous locations.\u003c\/p\u003e\n\u003cp\u003eThis conformally coated assembly (designated by the \"MC-\" prefix) is built for installation in harsh industrial environments where exposure to high humidity or atmospheric pollutants (ISA G3\/GX rated) is present. The \u003cstrong\u003eHoneywell MC-GHAO11 51309540-175\u003c\/strong\u003e incorporates dedicated connectors and built-in filtering for an external HART subsystem, allowing bi-directional digital HART communication to pass through without interfering with TPS analog control loops.\u003c\/p\u003e\n\u003cp\u003eFeaturing a Size B footprint with compression-type field wiring terminals, the \u003cstrong\u003eHoneywell MC-GHAO11 51309540-175\u003c\/strong\u003e supports one-on-one IOP redundancy to ensure continuous automatic control during module servicing or processor switchovers. Unlike standard analog output field termination assemblies, the \u003cstrong\u003eMC-GHAO11\u003c\/strong\u003e is specifically engineered for galvanically isolated intrinsically safe loops and does not incorporate standby manual unit connectors.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProvides 16 galvanically isolated 4-20 mA output channels for field devices operating in intrinsically safe and hazardous applications.\u003c\/li\u003e\n\u003cli\u003eIncludes integrated HART subsystem connectors and onboard noise filters to prevent signal interference between digital HART communication and TPS control signals.\u003c\/li\u003e\n\u003cli\u003eSupports 1-on-1 I\/O redundancy when paired with redundant \u003cstrong\u003eMC-PAOY22\u003c\/strong\u003e or \u003cstrong\u003eMU-PAOY22\u003c\/strong\u003e Analog Output Processors.\u003c\/li\u003e\n\u003cli\u003eConformally coated circuit board construction rated for harsh G3\/GX corrosive environmental conditions.\u003c\/li\u003e\n\u003cli\u003eEquipped with compression-type screw terminal blocks accommodating field wiring up to 14 AWG (1.6 mm).\u003c\/li\u003e\n\u003cli\u003eCE-Mark compliant for European industrial control equipment installation standards.\u003c\/li\u003e\n\u003cli\u003eProvides maximum output compliant voltage of 17.4 V and supports resistive loads up to 870 ohms at 20 mA.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDriving 4-20 mA control valves, I\/P converters, and variable speed drives located in Class 1 Div 1 or CENELEC Zone 0 hazardous plant areas.\u003c\/li\u003e\n\u003cli\u003eIntegrating HART-enabled smart positioners and field actuators with TPS APM, HPM, and EHPM controller hardware.\u003c\/li\u003e\n\u003cli\u003eHigh-availability industrial process control loops requiring redundant I\/O processing and galvanic signal isolation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003eMC-GHAO11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e51309540-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eGalvanically Isolated \/ Intrinsically Safe Analog Output FTA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible IOP\u003c\/td\u003e\n\u003ctd\u003eMU-PAOY22 \/ MC-PAOY22 (16-Point AO IOP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e16 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal Type\u003c\/td\u003e\n\u003ctd\u003e4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibrated Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.45% full-scale at 25 degC (including linearity)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Temperature Stability\u003c\/td\u003e\n\u003ctd\u003e±0.025% full-scale \/ degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current Linearity\u003c\/td\u003e\n\u003ctd\u003e±0.05% nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e±0.05%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDirectly Settable Output Range\u003c\/td\u003e\n\u003ctd\u003e0 mA, 2.9 mA to 21.1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Resistive Load\u003c\/td\u003e\n\u003ctd\u003e870 ohms @ 20 mA (with 20 V supply)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Output Compliant Voltage\u003c\/td\u003e\n\u003ctd\u003e17.4 V (with 20 V supply)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Settling Time\u003c\/td\u003e\n\u003ctd\u003e4 ms (digital code to 98% of final value)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Ripple\u003c\/td\u003e\n\u003ctd\u003e100 mV peak-to-peak at line frequency across 250 ohm load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity Stability Effect\u003c\/td\u003e\n\u003ctd\u003e±0.1% full-scale (50% RH ±40% RH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Block Type\u003c\/td\u003e\n\u003ctd\u003eCompression terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFTA Board Size\u003c\/td\u003e\n\u003ctd\u003eSize B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Rating\u003c\/td\u003e\n\u003ctd\u003eConformally Coated (ISA G3 \/ GX Harsh Environment)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHART Interface\u003c\/td\u003e\n\u003ctd\u003eIntegrated HART subsystem connector with signal filtering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandby Manual Support\u003c\/td\u003e\n\u003ctd\u003eNot Included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy Support\u003c\/td\u003e\n\u003ctd\u003eYes (supported with redundant AO16 IOP pairs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCE Compliance\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Wiring Terminals\u003c\/td\u003e\n\u003ctd\u003eCompression-type screw terminals accepting wire up to 14 AWG (~1.6 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIOP Interface Cables\u003c\/td\u003e\n\u003ctd\u003eDual multi-pin ribbon connectors for primary and redundant IOP cable attachment (up to 50 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHART Interface Connector\u003c\/td\u003e\n\u003ctd\u003eDedicated multi-pin header for external HART multiplexer\/subsystem interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eVerify that the \u003cstrong\u003eHoneywell MC-GHAO11 51309540-175\u003c\/strong\u003e hardware part number and conformal coating rating match system engineering requirements.\u003c\/li\u003e\n\u003cli\u003eDe-energize cabinet logic power and field power before installing or removing the FTA module from the standard mounting channel.\u003c\/li\u003e\n\u003cli\u003eMount the Size B FTA securely into the designated cabinet FTA mounting tray using standard Honeywell mounting hardware.\u003c\/li\u003e\n\u003cli\u003eConnect the system interface cable between the FTA and the corresponding \u003cstrong\u003eMC-PAOY22\u003c\/strong\u003e Analog Output Processor card file backplane connector.\u003c\/li\u003e\n\u003cli\u003eRoute field output signal cables away from high-voltage AC wiring and terminate conductors using the compression screw terminals.\u003c\/li\u003e\n\u003cli\u003eVerify protective earthing and grounding connections in accordance with hazardous area wiring standards and OEM guidelines.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eCommissioning \/ Replacement Recommendations\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eWhen replacing an existing unit, confirm that the replacement board carries the \u003cstrong\u003eMC-GHAO11\u003c\/strong\u003e conformal coating symbol for harsh environment protection.\u003c\/li\u003e\n\u003cli\u003eInspect field loop resistance to ensure the total connected load does not exceed 870 ohms per channel.\u003c\/li\u003e\n\u003cli\u003eIf HART communication filters are utilized, ensure external HART subsystem cable connections are properly seated.\u003c\/li\u003e\n\u003cli\u003eApply cabinet logic power and observe status LEDs on the associated \u003cstrong\u003eMC-PAOY22\u003c\/strong\u003e IOP to confirm normal communication and zero fault indication.\u003c\/li\u003e\n\u003cli\u003ePerform a channel-by-channel output current verification check prior to returning the control loop to automatic operation.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eRating\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCE-Mark\u003c\/td\u003e\n\u003ctd\u003eEuropean Low Voltage Directive (73\/23\/EEC) and EMC Directive (89\/336\/EEC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous Location Class\u003c\/td\u003e\n\u003ctd\u003eClass 1 Div 1 \/ Div 2 and CENELEC Zone 0 \/ Zone 1 (via galvanic isolators)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Severity\u003c\/td\u003e\n\u003ctd\u003eISA Environmental Severity Classification G3 \/ GX Harsh Environment (Conformally Coated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch2\u003e\u003cbr\u003e\u003c\/h2\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667992473963,"sku":"MC-GHAO11 51309540-175","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/MC-GHAO11-51309540-175_001_1200x1200_539bd5dd-7139-41c1-b5d1-191a0b7f40b6.jpg?v=1786878106"}],"url":"https:\/\/www.plcprotech.com\/it\/collections\/honeywell.oembed?page=2","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}