{"title":"I\/O Modules","description":"\u003cp\u003eI\/O Modules bridge the gap between physical field devices and the digital control environment of a PLC or DCS. The system architecture consists of isolated input channels for sensors and output channels for actuators, often housed in ruggedized, hot-swappable enclosures. Technical characteristics include optical isolation for circuit protection, varying voltage ranges (AC\/DC), and high-density channel configurations. Functionally, these modules convert analog or discrete electrical signals into data packets for the \u003ca href=\"https:\/\/www.plcprotech.com\/collections\/cpus\"\u003eCPU\u003c\/a\u003e to process. By utilizing modular \u003ca href=\"https:\/\/www.plcprotech.com\/collections\/iota-bases\"\u003eIOTA and bases\u003c\/a\u003e, they enable flexible system expansion and simplified field wiring, ensuring precise monitoring and control of industrial machinery and process loops.\u003c\/p\u003e","products":[{"product_id":"bently-nevada-289837-01-3500-encore-proximitor-seismic-i-o-module","title":"Bently Nevada 289837-01 3500 ENCORE Modulo I\/O Proximitor\/sismico","description":"\u003ch3\u003ePanoramica del prodotto\u003c\/h3\u003e\n\u003cp\u003eIl\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e289837-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eè un modulo I\/O Proximitor\/sismico ad alte prestazioni, progettato specificamente per il sistema di protezione delle macchine Bently Nevada 3500 ENCORE. Questo modulo funge da interfaccia critica sul pannello posteriore per il monitor di vibrazioni 3500\/42E, consentendo il collegamento di un massimo di quattro canali di trasduttori di prossimità o sismici. Ampiamente utilizzato nei settori della produzione di energia, del petrolio e del gas e dell'industria mineraria, il\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e289837-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econsente di monitorare parametri essenziali delle macchine, tra cui vibrazioni radiali, posizione assiale ed eccentricità. Grazie al condizionamento e alla trasmissione affidabili del segnale al processore principale, questo modulo I\/O garantisce la protezione continua delle macchine e l'acquisizione di dati ad alta fedeltà. È un componente essenziale per gli impianti che passano dai sistemi legacy 3300 alla piattaforma ENCORE, consentendo di modernizzare il monitoraggio delle vibrazioni senza compromettere l'integrità del cablaggio di campo.\u003c\/p\u003e\n\u003ch3\u003eConfigurazione tecnica\u003c\/h3\u003e\n\u003cp\u003eIl modulo I\/O\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e289837-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eè progettato per supportare le funzionalità a doppia architettura della serie 3500 ENCORE, garantendo la massima flessibilità per il monitoraggio delle vibrazioni e della posizione.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCapacità a quattro canali:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003equando viene utilizzato in un rack di sistema 3500 ENCORE standard, il modulo supporta quattro canali indipendenti, programmati a coppie (canali 1 e 2; canali 3 e 4) per eseguire funzioni di monitoraggio specifiche.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVersatilità dei trasduttori:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecompatibile con un'ampia gamma di sensori, comprese le sonde di prossimità per le misurazioni dei cuscinetti a film fluido e i trasduttori sismici (accelerometri o sensori di velocità) per le vibrazioni del basamento.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrazione del sistema:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein una configurazione di sistema 3500 ENCORE, il modulo I\/O si interfaccia con moduli relè programmabili tramite logica per azionare i circuiti di arresto delle macchine in base ai setpoint di Allarme e Pericolo definiti dall'utente.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLogica di condizionamento:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eogni canale elabora i segnali grezzi del trasduttore trasformandoli in \"valori statici\", fornendo al personale operativo diagnosi in tempo reale dello stato delle macchine, sia in condizioni stazionarie sia transitorie.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifiche tecniche\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttributo\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecifiche\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModello\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e289837-01\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMarchio\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSerie\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3500 ENCORE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTipo di modulo\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModulo I\/O Proximitor\/sismico\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSupporto dei canali\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 canali (modalità sistema) \/ 2 canali (aggiornamento del rack)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTemperatura di esercizio\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDa -20 a +65 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTemperatura di stoccaggio\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDa -40 a +85 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eUmidità\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e95 percento senza condensa\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePeso\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0,68 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensioni\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e208,28 mm x 48,26 mm x 127 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFAQ sulle applicazioni industriali\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIl 289837-01 può essere utilizzato come ricambio diretto per i moduli I\/O della serie 3300?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. Sebbene il sistema 3500 ENCORE sia progettato per aggiornare i monitor 3300, il\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e289837-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eè destinato specificamente all'uso nel rack di sistema 3500 ENCORE. Nelle configurazioni di \"aggiornamento del rack\", in cui resta in uso il telaio 3300, il sistema utilizza i moduli I\/O 3300 già presenti.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuesto modulo I\/O supporta contemporaneamente le vibrazioni radiali e la posizione assiale?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSì. Poiché i canali sono programmati a coppie, è possibile configurare i canali 1 e 2 per le vibrazioni radiali, mentre i canali 3 e 4 vengono configurati per la posizione assiale (o per qualsiasi altra funzione supportata) nello stesso monitor 3500\/42E.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCome gestisce il modulo i guasti del segnale, ad esempio un sensore scollegato?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIl monitor 3500\/42E, interfacciato tramite il\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e289837-01\u003c\/strong\u003e, esegue continuamente autotest. Se il segnale di un trasduttore viene interrotto o il cablaggio di campo è compromesso, il monitor segnala uno stato \"Non OK\", prevenendo arresti intempestivi e avvisando il personale di manutenzione tramite il software 3500 Rack Configuration.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eGuida all'ingegneria di campo e all'installazione\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCablaggio e schermatura:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003equando si collegano i sensori Proximitor o sismici ai terminali del\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e289837-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e, assicurarsi che le schermature dei cavi siano terminate esclusivamente sulla messa a terra del modulo I\/O. Non collegare a terra le schermature all'estremità del trasduttore, per evitare anelli di massa che possono introdurre rumore e compromettere la precisione delle misurazioni delle vibrazioni.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSerraggio durante l'installazione:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eassicurarsi che il modulo I\/O sia completamente inserito nella parte posteriore del rack ENCORE e che le viti di fissaggio siano serrate per bloccare il modulo contro il backplane. Questo è fondamentale per mantenere l'integrità del segnale in ambienti soggetti a forti vibrazioni, tipici delle piattaforme dei compressori o delle sale turbine.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtezione ambientale:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esebbene il modulo sia classificato per un'umidità fino al 95 percento senza condensa, deve essere sempre installato in un involucro con grado di protezione NEMA 4 o IP65 se collocato in aree con elevata umidità o sostanze chimiche corrosive. Assicurarsi che all'interno del rack vi sia un flusso d'aria adeguato per mantenere la temperatura di esercizio al di sotto della soglia di 65 °C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVerifica della configurazione:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edopo aver sostituito un modulo I\/O, utilizzare sempre il software 3500 Rack Configuration per verificare che gli abbinamenti dei canali e i tipi di trasduttore corrispondano ai sensori installati sul campo. Eseguire un controllo del loop per assicurarsi che i setpoint di Allarme e Pericolo azionino correttamente i moduli relè associati.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666516898155,"sku":"3500\/42E 289837-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-42e-289837-01-vibration-monitor-5lwybpzw3c4_d9f2ca71-9841-4ea7-b237-17c1fd8f0f71.jpg?v=1765440098"},{"product_id":"bently-nevada-133819-02-3500-61-rtd-tc-non-isolated-i-o-module","title":"Bently Nevada 133819-02 3500\/61 Modulo I\/O RTD\/TC non isolato","description":"\u003ch3\u003ePanoramica del prodotto\u003c\/h3\u003e\n\u003cp\u003eIl \u003cspan\u003eBently Nevada \u003cstrong\u003e133819-02\u003c\/strong\u003e\u003c\/span\u003e è uno \u003cspan\u003emodulo I\/O RTD\/TC non isolato\u003c\/span\u003e specializzato, progettato per il \u003cstrong\u003emonitor di temperatura 3500\/61.\u003c\/strong\u003e Questo modulo fornisce l’interfaccia fisica per il monitoraggio della temperatura su sei canali e supporta sia i rilevatori di temperatura a resistenza (RTD) sia le termocoppie (TC). Il modello \u003cspan\u003e133819-02\u003c\/span\u003e dispone di \u003cspan\u003econnessioni interne\u003c\/span\u003e, consentendo di collegare direttamente il cablaggio di campo alle morsettiere presenti sul modulo I\/O. Questa versione non isolata offre la massima flessibilità, permettendo agli utenti di configurare il modulo per TC, RTD o una combinazione di entrambi i tipi di sensore sui sei canali.\u003c\/p\u003e\n\u003ch3\u003eFunzionalità intelligenti e uscite per registratore\u003c\/h3\u003e\n\u003cp\u003eIn quanto componente della serie \u003cspan\u003e3500\/61\u003c\/span\u003e, questo modulo I\/O include \u003cspan\u003euscite per registratore\u003c\/span\u003e dedicate per ciascuno dei sei canali. Fornisce un segnale da \u003cspan\u003e+4 a +20 mA\u003c\/span\u003e proporzionale all’intero intervallo di misura del monitor, consentendo una perfetta integrazione con sistemi di controllo esterni, DCS o registratori a carta per la registrazione dei dati. L’architettura del modulo è tollerante ai guasti; il funzionamento del monitor non viene compromesso dai cortocircuiti sulle uscite per registratore, garantendo che le funzioni primarie di protezione dei macchinari rimangano attive.\u003c\/p\u003e\n\u003ch3\u003eSpecifiche tecniche\u003c\/h3\u003e\n\u003ctable width=\"692\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cspan\u003eAttributo\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eDettagli delle specifiche\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNumero di parte\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e133819-02\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCompatibilità del monitor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada 3500\/61\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCanali di ingresso\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6 (programmabili singolarmente per RTD o TC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTipo di connessione\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eConnessioni interne (sul modulo)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIsolamento\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNon isolato\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSorgente di corrente RTD\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e925 \u003cspan class=\"math-inline\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e±\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e 15 \u003cspan class=\"math-inline\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord mathnormal\"\u003eμ\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eA a 25 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUscita per registratore\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e+4 a +20 mA (carico: da 0 a 600 \u003cspan class=\"math-inline\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003eΩ\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePrecisione (interna)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan class=\"math-inline\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e±\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e 3 °C a 25 °C (\u003cspan class=\"math-inline\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e±\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e 5.4 °F a 77 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTemperatura di esercizio\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eda -30 °C a +65 °C (da -22 °F a +150 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePeso\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.45 kg (1.0 lb)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensioni (A x L x P)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e241.3 mm x 24.4 mm x 99.1 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDomande frequenti tecniche\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eQual è la differenza principale tra i moduli 3500\/60 e 3500\/61?\u003c\/span\u003eEntrambi i moduli offrono una funzionalità identica di monitoraggio della temperatura su sei canali. Tuttavia, il modello \u003cspan\u003e3500\/61\u003c\/span\u003e (che utilizza il modulo I\/O \u003cspan\u003e133819-02\u003c\/span\u003e) include uscite per registratore da 4-20 mA per ciascun canale, mentre il modello 3500\/60 non dispone di queste uscite analogiche.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eÈ possibile combinare diversi tipi di sensore su un singolo modulo 133819-02?\u003c\/span\u003eSì. A differenza delle versioni isolate, questo modulo I\/O non isolato può essere configurato tramite il \u003cspan\u003e3500 Rack Configuration Software\u003c\/span\u003e per accettare qualsiasi combinazione di ingressi TC e RTD sui sei canali.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCome gestisce il modulo il cablaggio degli RTD?\u003c\/span\u003eIl modulo fornisce una sorgente di corrente specializzata da \u003cspan\u003e925 \u003cspan class=\"math-inline\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord mathnormal\"\u003eμ\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003eA\u003c\/span\u003e. È progettato per supportare RTD a 3 fili (utilizzando due alimentazioni di corrente per la compensazione dei fili) e RTD a 4 fili (utilizzando una singola alimentazione), garantendo una misurazione accurata della temperatura con diversi tipi di trasduttore.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eGuida all’ingegneria sul campo e all’installazione\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eGestione delle connessioni interne:\u003c\/span\u003e Il modello \u003cspan\u003e133819-02\u003c\/span\u003e utilizza morsettiere interne. Assicurarsi che il cablaggio di campo sia correttamente etichettato e fissato saldamente per evitare segnali intermittenti, che potrebbero attivare i LED di stato “Bypass” o “Error” sul pannello anteriore del monitor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eConsiderazioni ambientali:\u003c\/span\u003e Il modulo è progettato per un intervallo di temperatura di esercizio compreso tra \u003cspan\u003e-30 °C e +65 °C\u003c\/span\u003e. Per le installazioni in ambienti estremi, assicurarsi che il rack 3500 disponga di una ventilazione adeguata per mantenere questi limiti ed evitare derive della precisione.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eConfigurazione TMR:\u003c\/span\u003e Quando viene utilizzato in applicazioni a ridondanza modulare tripla (TMR), è necessario installare tre monitor di temperatura in gruppi adiacenti. Il sistema utilizza due tipi di votazione per impedire che guasti a punto singolo causino arresti falsi nei macchinari critici.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eVantaggi ingegneristici\u003c\/h3\u003e\n\u003cp\u003eIl modello \u003cspan\u003eBently Nevada 133819-02\u003c\/span\u003e offre una soluzione conveniente e ad alta densità per la protezione dei macchinari basata sulla temperatura. Combinando il supporto per TC e RTD in un unico modulo con connessioni interne, riduce lo spazio necessario nell’armadio e semplifica la complessità del cablaggio. Per gli approvvigionamenti B2B, scegliere il modello originale \u003cspan\u003e133819-02\u003c\/span\u003e garantisce la piena compatibilità con il \u003cspan\u003e3500 Monitoring System\u003c\/span\u003e, mantenendo l’elevata precisione e la robustezza necessarie per proteggere turbine, compressori e grandi motori industriali.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666518864235,"sku":"133819-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-133819-02-rtd-tc-temp-i-o-module-olhm4jqsb0w_ea2a25c8-3e12-4f5e-a5c2-4a168d80f750.jpg?v=1765440121"},{"product_id":"bently-nevada-133442-01-3500-50m-i-o-module-with-internal-terminations","title":"Bently Nevada 133442-01 3500\/50M Modulo I\/O con terminazioni interne","description":"\u003ch3\u003ePanoramica del prodotto\u003c\/h3\u003e\n\u003cp\u003eIl Bently Nevada\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e133442-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eè un modulo di ingresso\/uscita (I\/O) tachimetrico a doppio canale progettato per il sistema di protezione delle macchine della serie 3500. Questo modulo funge da interfaccia fisica principale per il cablaggio di campo, appositamente progettata per funzionare con\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/50\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ee\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/50M\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eModuli principali del tachimetro. Elabora ingressi a impulsi ad alta frequenza provenienti da sonde di prossimità o pickup magnetici passivi per consentire misurazioni precise della velocità di rotazione, dell'accelerazione del rotore e della rotazione inversa.\u003c\/p\u003e\n\u003cp\u003eIn quanto variante con terminazioni interne, il\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e133442-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eintegra morsettiere a vite direttamente nel corpo del modulo, ottimizzandolo per installazioni in armadi ad alta densità dove lo spazio è una priorità. Questa configurazione hardware è ampiamente utilizzata in impianti di generazione elettrica, petrolchimici e di compressione del gas per il monitoraggio continuo delle macchine e la protezione critica contro il fuorigiri.\u003c\/p\u003e\n\u003ch3\u003eSpecifiche tecniche\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParametro\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecifica\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModello\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e133442-01\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMarchio\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTipo di prodotto\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModulo I\/O tachimetro con terminazioni interne\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSerie\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSerie 3500\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCanali d'ingresso\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIngressi a impulsi differenziali a 2 canali o single-ended\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCompatibilità del segnale\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSistemi con sonde di prossimità, pickup magnetici\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIntervallo del segnale d'ingresso\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDa +10,0 Vcc a -24,0 Vcc (limitato internamente)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eImpedenza d'ingresso\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7,15 kΩ (variante con barriera interna)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensioni (A x L x P)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e241,3 mm x 24,4 mm x 163,1 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePeso\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0,46 kg (1,01 lb)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTemperatura di esercizio\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDa -30 °C a +65 °C (da -22 °F a +149 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eGrado di protezione\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigine\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInformazioni per l'ordine\u003c\/h3\u003e\n\u003cp\u003eQuando si acquistano parti di ricambio, assicurarsi che il numero di parte corrisponda alla configurazione specifica del rack per evitare errori di incompatibilità hardware\/software.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNumero di parte\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e133442-01\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDescrizione del componente\u003c\/strong\u003e: modulo I\/O tachimetro 3500\/50M con terminazioni interne (tipo a barriera interna)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModulo principale associato\u003c\/strong\u003e: 3500\/50-01-XX o\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/50M-01-XX\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTipo di terminale\u003c\/strong\u003e: morsettiere a vite fisse\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eGuida alla progettazione e al cablaggio in campo\u003c\/h3\u003e\n\u003ch3\u003eRequisiti di cablaggio e schermatura\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eScelta dei cavi\u003c\/strong\u003e: utilizzare cavi a doppino intrecciato e schermato (da 18 AWG a 22 AWG) per tutti i collegamenti dei trasduttori, al fine di ridurre le interferenze elettromagnetiche.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMessa a terra delle schermature\u003c\/strong\u003e: collegare le schermature al terminale di terra dello strumento designato sul telaio del rack 3500 a un'estremità soltanto. Non effettuare la messa a terra sul trasduttore in campo per evitare loop di massa.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeparazione dei segnali\u003c\/strong\u003e: mantenere una distanza minima di 300 mm (12 pollici) tra i cavi dei sensori di velocità e le linee di alimentazione CA ad alta tensione.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePrecauzioni per l'installazione e la sostituzione a caldo\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAllineamento del rack\u003c\/strong\u003e: il\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e133442-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edeve essere installato nello slot posteriore corrispondente al processore principale 3500\/50M montato anteriormente.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtocollo di bypass\u003c\/strong\u003e: prima di estrarre o inserire il modulo, escludere tutti i relè di intervento associati dei macchinari per evitare l'attivazione accidentale degli interventi della turbina o del compressore.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLimiti di coppia\u003c\/strong\u003e: serrare le viti della morsettiera a un massimo di 0.56 N·m (5 in·lb) per proteggere le piste interne del PCB.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDomande frequenti\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIl modello 133442-01 è compatibile con i moduli 3500\/50 più vecchi?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSì, è completamente compatibile con le versioni precedenti dei moduli standard 3500\/50 e dei moduli aggiornati 3500\/50M, a condizione che il software di configurazione del rack corrisponda alla variante hardware.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQual è la differenza tra questa versione e la versione con terminazione esterna (ET)?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eLa\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e133442-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edispone di morsettiere integrate. La versione ET richiede un cavo multipolare per il collegamento a una morsettiera per guida DIN remota.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQuali sono i rischi del superamento dell'intervallo del segnale d'ingresso?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSebbene i circuiti di limitazione interni limitino le tensioni, una sovratensione prolungata al di fuori dell'intervallo da +10 V a -24 V può degradare i circuiti interni della barriera e causare guasti ai canali.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666519650667,"sku":"133442-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-133442-01-i-o-module-with-internal-terminations-1a4iq1cd4r4_bc83d92f-d0df-4c88-95ae-2fed0e219041.jpg?v=1765440137"},{"product_id":"bently-nevada-133819-01-3500-60-rtd-tc-non-isolated-i-o-module","title":"Bently Nevada 133819-01 3500\/60 Modulo I\/O RTD\/TC non isolato","description":"\u003ch3\u003eDescrizione\u003c\/h3\u003e\n\u003cp\u003eIl \u003cstrong\u003eBently Nevada 133819-01\u003c\/strong\u003e è un \u003cstrong\u003emodulo I\/O RTD\/TC non isolato 3500\/60\u003c\/strong\u003e con montaggio posteriore e dotato di \u003cstrong\u003eterminazioni interne\u003c\/strong\u003e, progettato per il Sistema di protezione dei macchinari della serie 3500. Fornisce connessioni ai morsetti per un massimo di sei segnali di rilevatori di temperatura a resistenza (RTD) o termocoppie (TC), trasferendo i dati di temperatura condizionati al modulo monitor principale 3500\/60. Il \u003cstrong\u003e133819-01\u003c\/strong\u003e accetta ingressi RTD e TC misti sui sei canali e utilizza morsettiere interne dirette a vite\/header per il cablaggio dei trasduttori di campo, senza richiedere morsettiere di terminazione esterne.\u003c\/p\u003e\n\u003ch3\u003eCaratteristiche\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAccetta fino a 6 ingressi di trasduttori RTD o termocoppia con condizionamento del segnale non isolato.\u003c\/li\u003e\n\u003cli\u003eMorsettiere interne integrate per il collegamento diretto del cablaggio di campo.\u003c\/li\u003e\n\u003cli\u003eSupporta configurazioni miste di sensori RTD e TC tra i canali tramite il software di configurazione del rack.\u003c\/li\u003e\n\u003cli\u003eSi installa direttamente in un singolo slot posteriore a tutta altezza del sistema rack 3500.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplicazioni\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMonitoraggio della temperatura dei macchinari per apparecchiature rotanti industriali\u003c\/li\u003e\n\u003cli\u003eProtezione della temperatura di cuscinetti e avvolgimenti negli impianti di generazione elettrica e petrolchimici\u003c\/li\u003e\n\u003cli\u003eMonitoraggio continuo dello stato degli asset integrato nei sistemi TSI Bently Nevada della serie 3500\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInformazioni per l'ordine\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCodice \/ Opzione\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescrizione\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/60-01-00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModulo I\/O RTD\/TC non isolato 3500\/60, terminazioni interne, senza certificazioni\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/60-01-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModulo I\/O RTD\/TC non isolato 3500\/60, terminazioni interne, certificazione CSA\/NRTL\/C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/60-01-02\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModulo I\/O RTD\/TC non isolato 3500\/60, terminazioni interne, certificazioni ATEX\/IECEx\/CSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e133819-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModulo I\/O RTD\/TC non isolato di ricambio 3500\/60 con terminazioni interne\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSpecifiche tecniche\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCategoria\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eParametro\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecifiche\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacità di ingresso\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIngressi per segnali di trasduttori\u003c\/td\u003e\n\u003ctd\u003eAccetta da 1 a 6 segnali RTD o TC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTipi di RTD supportati\u003c\/td\u003e\n\u003ctd\u003ePt a 3 fili\/4 fili da 100 ohm (alfa = 0.00385 o 0.00392), Ni a 3 fili\/4 fili da 120 ohm, Cu a 3 fili\/4 fili da 10 ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTipi di TC supportati\u003c\/td\u003e\n\u003ctd\u003eTipo E, Tipo J, Tipo K, Tipo T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eImpedenza d'ingresso\u003c\/td\u003e\n\u003ctd\u003e10 MΩ per ciascun ingresso del cavo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCaratteristiche fisiche\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSpazio richiesto nel rack\u003c\/td\u003e\n\u003ctd\u003e1 slot posteriore a tutta altezza\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eDimensioni (A x L x P)\u003c\/td\u003e\n\u003ctd\u003e241,3 mm x 24,4 mm x 99,1 mm (9,50 pollici x 0,96 pollici x 3,90 pollici)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003ePeso\u003c\/td\u003e\n\u003ctd\u003e0,45 kg (1,0 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondizioni ambientali\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTemperatura di esercizio\u003c\/td\u003e\n\u003ctd\u003e-30 °C a +65 °C (-22 °F a +150 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTemperatura di stoccaggio\u003c\/td\u003e\n\u003ctd\u003e-40 °C a +85 °C (-40 °F a +185 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eUmidità relativa\u003c\/td\u003e\n\u003ctd\u003e95% senza condensa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eCollegamenti\/interfacce\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003ePin del connettore \/ morsettiera\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunzione\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMorsettiera interna\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCollegamenti degli ingressi di segnale per i canali RTD\/TC da 1 a 6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnettore 00580442\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMorsettiera interna verde a 9 posizioni\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnettore 00580443\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMorsettiera interna verde a 12 posizioni\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnettore 00580444\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMorsettiera interna verde a 15 posizioni\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eLinee guida per l'installazione\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstallare il modulo nello slot posteriore del rack 3500, direttamente allineato dietro al modulo monitor principale 3500\/60 corrispondente.\u003c\/li\u003e\n\u003cli\u003eFissare la scheda in posizione serrando le viti di montaggio prigioniere superiori e inferiori.\u003c\/li\u003e\n\u003cli\u003eCollegare i cavi del sensore RTD o della termocoppia di campo direttamente ai connettori verdi dei morsetti interni, seguendo le linee guida appropriate per il cablaggio di campo.\u003c\/li\u003e\n\u003cli\u003eAssicurarsi che la schermatura dei cavi sia adeguata per ridurre al minimo le interferenze elettromagnetiche nei circuiti a bassa tensione per la misurazione di termocoppie e resistenze.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConformità e certificazioni\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDirettiva EMC\u003c\/strong\u003e: 2014\/30\/UE (EN 61000-6-2, EN 61000-6-4)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDirettiva bassa tensione\u003c\/strong\u003e: 2014\/35\/UE (EN 61010-1)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDirettiva RoHS\u003c\/strong\u003e: 2011\/65\/UE\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCybersecurity\u003c\/strong\u003e: progettato per soddisfare la norma IEC 62443\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSicurezza funzionale\u003c\/strong\u003e: classificato SIL 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOmologazioni marittime\u003c\/strong\u003e: regole DNV GL, regole ABS\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOmologazioni per aree pericolose\u003c\/strong\u003e: CSA\/NRTL\/C (Classe I, Div 2 \/ Zona 2), ATEX\/IECEx (Ex nA nC ic IIC T4 Gc \/ Ex ec nC ic IIC T4 Gc)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666520174955,"sku":"133819-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-133819-01-rtd-tc-temp-i-o-module-internal-termination-0agjwchdyju_12e8579b-0489-49e2-83f4-a0d5b2bd6141.jpg?v=1765440147"},{"product_id":"bently-nevada-136711-02-3500-61-rtd-tc-i-o-module","title":"Bently Nevada 136711-02 3500\/61 Modulo I\/O RTD\/TC","description":"\u003ch3\u003eDescrizione\u003c\/h3\u003e\n\u003cp\u003eIl \u003cstrong\u003eBently Nevada 136711-02\u003c\/strong\u003e è uno \u003cstrong\u003emodulo I\/O RTD\/TC con barriere interne e terminazioni interne\u003c\/strong\u003e specializzato, sviluppato per il \u003cstrong\u003emonitor della temperatura a 16 canali 3500\/61\u003c\/strong\u003e all'interno del \u003cstrong\u003esistema di protezione dei macchinari della serie 3500\u003c\/strong\u003e. Questo componente hardware funge da livello di interfaccia fisica che raccoglie i segnali di temperatura multicanale dai trasduttori situati sul campo. Questa specifica variante non isolata è progettata con barriere di sicurezza integrate, consentendo agli utenti di configurare i percorsi di terminazione per accettare ingressi da termocoppie (TC) o rilevatori di temperatura a resistenza (RTD), nonché una combinazione flessibile di entrambe le categorie di sensori simultaneamente all'interno dello stesso sottosistema rack.\u003c\/p\u003e\n\u003cp\u003eLa programmazione e la configurazione sul campo dei tipi di canale vengono gestite tramite il \u003cstrong\u003e3500 Rack Configuration Software\u003c\/strong\u003e, eliminando qualsiasi necessità di modifiche fisiche all'hardware o di procedure di calibrazione sul campo. Il modulo condiziona i segnali grezzi in millivolt provenienti dalle termocoppie e le variazioni di resistenza degli RTD a 3 o 4 fili, fornendo valori digitali strutturati della temperatura direttamente alla scheda principale del processore anteriore tramite il bus del backplane interno. Il design di sicurezza intrinseca integrato offre un elevato livello di integrazione combinando blocchi di terminazione e barriere di contenimento per aree pericolose in un'unica struttura compatta, rendendo il sottosistema \u003cstrong\u003e3500\/61\u003c\/strong\u003e ideale per la sorveglianza termica multipunto di cuscinetti, avvolgimenti dello statore e condotti di scarico su macchinari rotanti pesanti.\u003c\/p\u003e\n\u003ch3\u003eCaratteristiche\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOspita blocchi di terminazione fisici interni abbinati a barriere di sicurezza integrate per ambienti di campo pericolosi.\u003c\/li\u003e\n\u003cli\u003eI percorsi dei canali universali non isolati supportano la configurazione individuale per TC, RTD a 3 fili o RTD a 4 fili.\u003c\/li\u003e\n\u003cli\u003eElimina la necessità di calibrare manualmente i componenti grazie alla piena integrazione con il \u003cstrong\u003e3500 Rack Configuration Software\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eInclude reti dedicate di sorgenti di corrente ad alta precisione per supportare i circuiti di misura RTD a più fili.\u003c\/li\u003e\n\u003cli\u003eLa progettazione strutturale ottimizza l'ingombro del rack consolidando le scatole di terminazione esterne e l'hardware separato per la sicurezza intrinseca in un unico slot posteriore.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplicazioni\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMonitoraggio termico multicanale degli avvolgimenti dello statore di motori e generatori.\u003c\/li\u003e\n\u003cli\u003eMonitoraggio del profilo e mappatura della distribuzione della temperatura dei gas di scarico (EGT) delle turbine a gas.\u003c\/li\u003e\n\u003cli\u003eMonitoraggio industriale della temperatura dei cuscinetti su pompe, ventilatori e riduttori ad alta velocità.\u003c\/li\u003e\n\u003cli\u003eProtezione dei macchinari ausiliari dell'impianto nelle strutture chimiche e petrolchimiche.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInformazioni per l'ordine\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e136711-02: modulo I\/O RTD\/TC con barriere interne e terminazioni interne (non isolato)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifiche tecniche\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParametro \/ Categoria\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDettagli delle specifiche\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElettricità e alimentazione\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduttore\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePaese di origine\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSottotipo del modulo\u003c\/td\u003e\n\u003ctd\u003eNon isolato con barriere di sicurezza interne\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eValore della sorgente di corrente RTD\u003c\/td\u003e\n\u003ctd\u003e925 +\/- 15 uA a 25 degC per trasduttore (1 alimentazione per RTD a 4 fili, 2 alimentazioni per RTD a 3 fili)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIngressi di trasduttori e sensori\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacità delle termocoppie (TC)\u003c\/td\u003e\n\u003ctd\u003eTipo E, Tipo J, Tipo K, Tipo T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntervalli di temperatura delle termocoppie\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eTipo E: -100 degC a +1000 degC (-148 degF a +1832 degF)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003eTipo J: -18 degC a +760 degC (+0 degF a +1400 degF)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003eTipo K: -18 degC a +1370 degC (+0 degF a +2498 degF)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003eTipo T: -160 degC a +400 degC (-256 degF a +752 degF)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRilevatore di temperatura a resistenza (RTD)\u003c\/td\u003e\n\u003ctd\u003ePlatino da 100 Ohm (alfa = 0,00385), platino da 100 Ohm (alfa = 0,00392), nichel da 120 Ohm, rame da 10 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntervalli di misura RTD\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePlatino da 100 Ohm (0,00385): -200 degC a +850 degC (-328 degF a +1562 degF)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003ePlatino da 100 Ohm (0,00392): -200 degC a +700 degC (-328 degF a +1292 degF)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003eNichel da 120 Ohm: -80 degC a +260 degC (-112 degF a +500 degF)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003eRame da 10 Ohm: -100 degC a +260 degC (-148 degF a +500 degF)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntervalli con barriere esterne\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePlatino da 100 Ohm (0,00385): -50 degC a +850 degC (-122 degF a +1562 degF)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003ePlatino da 100 Ohm (0,00392): -50 degC a +260 degC (-122 degF a +1292 degF)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003eNichel da 120 Ohm: -50 degC a +260 degC (-122 degF a +500 degF)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003eRame da 10 Ohm: -50 degC a +260 degC (-122 degF a +500 degF)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondizionamento del segnale e precisione\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRisoluzione di misura\u003c\/td\u003e\n\u003ctd\u003e1 degC o 1 degF (eccetto per gli RTD in rame da 10 Ohm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrecisione della terminazione esterna non isolata\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eRack bulkhead: +\/-3 degC a 25 degC (+\/-5,4 degF a 77 degF)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003eRack standard: +\/-1 degC a 25 degC (+\/-1,8 degF a 77 degF)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrecisione della terminazione interna isolata\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eRack bulkhead: +\/-2 degC a 25 degC (+\/-3,6 degF a 77 degF) \/ +\/-3 degC a 25 degC (+\/-5,4 degF a 77 degF)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003eRack standard: +\/-3 degC a 25 degC (+\/-5,4 degF a 77 degF)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibrazione\u003c\/td\u003e\n\u003ctd\u003eNon è necessaria alcuna calibrazione sul campo; specificata a +25 degC (+77 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLimiti ambientali\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperatura di esercizio\u003c\/td\u003e\n\u003ctd\u003e0 degC a +65 degC (32 degF a +150 degF) quando utilizzato con moduli con barriera interna\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperatura di stoccaggio\u003c\/td\u003e\n\u003ctd\u003e-40 degC a +85 degC (-40 degF a +185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensioni meccaniche e peso\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensioni del modulo I\/O (A x L x P)\u003c\/td\u003e\n\u003ctd\u003e241,3 mm x 24,4 mm x 163,1 mm (9,50 in x 0,96 in x 6,42 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeso del modulo\u003c\/td\u003e\n\u003ctd\u003e0,46 kg (1,01 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRequisiti per la posizione nel rack\u003c\/td\u003e\n\u003ctd\u003eOccupa 1 slot posteriore a tutta altezza direttamente dietro la scheda processore principale del monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnessioni\/Interfacce\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003ePin del connettore \/ morsettiera\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eAssegnazione delle funzioni\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMorsetti a vite interni con barriera\u003c\/td\u003e\n\u003ctd\u003eConnessione fisica diretta per i cavi RTD multipolari grezzi e le estensioni di campo TC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpina del bus del backplane interno\u003c\/td\u003e\n\u003ctd\u003eMatrice di interconnessione multipolare che trasmette i dati dei sensori condizionati al bus del rack 3500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eLinee guida per l'installazione\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAllineamento del telaio:\u003c\/strong\u003e installare il modulo \u003cstrong\u003e136711-02\u003c\/strong\u003e direttamente dal lato posteriore del telaio di monitoraggio 3500. Deve allinearsi perfettamente allo slot corrispondente alla scheda processore principale 3500\/61 montata frontalmente.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCorrispondenza del tipo di sensore:\u003c\/strong\u003e verificare tramite il software di configurazione che la configurazione di ciascun canale (termocoppia o RTD a 3 o 4 fili) corrisponda esattamente alla disposizione dei fili di campo collegati alla morsettiera.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUniformità dei fili di collegamento:\u003c\/strong\u003e per tutte le configurazioni RTD a 3 e 4 fili, utilizzare fili di rame di sezione e lunghezza uniformi per garantire una compensazione precisa della resistenza dei conduttori.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControllo della messa a terra delle schermature:\u003c\/strong\u003e far passare tutte le linee dei sensori esterni attraverso coppie di fili intrecciati e schermati. Collegare le schermature al terminale di terra per strumentazione designato, presente sul telaio del modulo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControllo ambientale:\u003c\/strong\u003e assicurarsi che l'installazione nell'armadio mantenga percorsi di ventilazione puliti e privi di ostruzioni, in modo che la temperatura ambiente operativa effettiva intorno all'alloggiamento della barriera interna non superi i 65 °C.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDomande frequenti\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQual è la funzione del componente 136711-02?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFunziona come modulo di interfaccia per terminali posteriori e sicurezza intrinseca, instradando i segnali RTD e delle termocoppie dal campo verso uno slot monitor 3500\/61.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eChe cosa significa la designazione “non isolato” per questo modulo?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIndica che i canali condividono un punto di riferimento di massa comune, pur rimanendo protetti da barriere di sicurezza interne integrate.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePosso combinare termocoppie e RTD sulla stessa scheda I\/O?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSì, i percorsi dei canali non isolati possono essere personalizzati individualmente tramite software per accettare una combinazione mista di termocoppie e RTD.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuale tipo specifico di RTD è consigliato per le installazioni ingegneristiche standard?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eGli RTD al platino con un valore alfa di 0,00385 sono lo standard industriale e sono altamente raccomandati per ottenere la massima precisione.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eÈ necessaria una calibrazione manuale sul campo dopo la sostituzione di questo hardware?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNon è necessaria alcuna calibrazione manuale sul campo, poiché il ridimensionamento dei parametri di tutti i canali viene gestito automaticamente tramite il software di configurazione del sistema.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuale valore di corrente costante fornisce questo modulo ai sensori RTD?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eLa rete di sorgenti di corrente integrata fornisce 925 +\/- 15 uA a una temperatura ambiente di riferimento di 25 °C per ciascun percorso del trasduttore.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuante alimentazioni interne in corrente vengono attivate quando è collegato un RTD a 4 fili?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eLa configurazione del modulo attiva una singola linea di alimentazione in corrente per un circuito RTD a 4 fili e due alimentazioni separate per un circuito RTD a 3 fili.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQual è il limite di temperatura operativa definito per questa versione del modulo?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIl modulo è progettato per funzionare in modo affidabile in un ambiente a temperatura ambiente continua compresa tra 0 °C e +65 °C.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuali sono le dimensioni fisiche esatte di questo componente con montaggio posteriore?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eLa scheda misura 241,3 mm in altezza, 24,4 mm in larghezza e 163,1 mm in profondità.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuesto componente contiene la scheda processore digitale principale?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, questo numero di parte rappresenta il gruppo di terminazione I\/O con inserimento posteriore e barriere integrate; il modulo processore anteriore viene fornito separatamente.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666520273259,"sku":"3500\/61 136711-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-61-136711-02-temperature-module-cnm5uk4ps0a_ea8ec829-abb6-47bf-af49-d0ad661bbb09.jpg?v=1765440149"},{"product_id":"bently-nevada-170180-02-00-fieldmonitor-external-transducer-i-o-module","title":"Bently Nevada 170180-02-00 modulo I\/O per trasduttore esterno FieldMonitor","description":"\u003ch3\u003eDescrizione\u003c\/h3\u003e\n\u003cp\u003eIl \u003cstrong\u003eBently Nevada 170180-02-00\u003c\/strong\u003e è un modulo I\/O per trasduttori esterni progettato per l'uso con il sistema di protezione dei macchinari FieldMonitor. Il \u003cstrong\u003e170180-02-00\u003c\/strong\u003e collega i trasduttori di velocità a 2 fili al rispettivo modulo di monitoraggio a 2 canali all'interno dell'unità FieldMonitor. Occupando un singolo slot in una base terminale FieldMonitor, fornisce l'instradamento del segnale e il condizionamento dell'interfaccia per due ingressi indipendenti per trasduttori di velocità a 2 fili. Questa configurazione specifica presenta un modulo I\/O a doppio canale per trasduttori di velocità con certificazione per aree pericolose Divisione 2 \/ Zona 2.\u003c\/p\u003e\n\u003ch3\u003eCaratteristiche\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCollega due ingressi indipendenti per trasduttori di velocità a 2 fili ai moduli di monitoraggio FieldMonitor\u003c\/li\u003e\n\u003cli\u003eOccupa uno slot in una base terminale FieldMonitor\u003c\/li\u003e\n\u003cli\u003eFornisce il condizionamento e l'instradamento dei segnali per due canali di trasduttori\u003c\/li\u003e\n\u003cli\u003eCertificato per aree pericolose Divisione 2 \/ Zona 2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplicazioni\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProtezione dei macchinari e monitoraggio delle condizioni per apparecchiature rotanti industriali\u003c\/li\u003e\n\u003cli\u003eIntegrazione della misurazione di vibrazioni e velocità per turbine, pompe, compressori e motori\u003c\/li\u003e\n\u003cli\u003eEspansione dei segnali nei sistemi con base terminale Bently Nevada FieldMonitor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInformazioni per l'ordinazione\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCodice prodotto\u003c\/th\u003e\n\u003cth\u003eDescrizione\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e170180-02-00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eModulo I\/O per trasduttori esterni FieldMonitor\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e02\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eTipo di trasduttore:\u003c\/strong\u003e modulo I\/O a doppio canale per trasduttori di velocità (Canale A: un trasduttore di velocità a 2 fili, Canale B: un trasduttore di velocità a 2 fili)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eOpzione di approvazione \/ ente:\u003c\/strong\u003e Divisione 2\/Zona 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSpecifiche tecniche\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCategoria del parametro\u003c\/th\u003e\n\u003cth\u003eDettagli delle specifiche\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduttore\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCodice prodotto\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e170180-02-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIngressi del segnale\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCanale A: un trasduttore di velocità a 2 fili; Canale B: un trasduttore di velocità a 2 fili\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIntervallo di tensione del segnale d'ingresso\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDa 0 a -Vt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIntervallo di tensione di uscita\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDa 0 a -Vt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRisposta in frequenza\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5% a \u0026gt;25 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImpedenza d'ingresso\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9,98 +\/- 0,02 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAssorbimento di corrente (senza trasduttore)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2,0 mA massimo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperatura di esercizio\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-34 degC a +85 degC (-30 degF a +185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperatura di stoccaggio\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 degC a +85 degC (-40 degF a +185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUmidità relativa\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100% di umidità relativa, con condensa, non immerso, da +7 degC a +85 degC (+45 degF a +185 degF) quando il connettore è protetto\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRequisiti dello slot\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOccupa 1 slot nella base terminale FieldMonitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePeso\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e277 g (0,61 lb) tipici\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eLinee guida per l'installazione\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePosizionamento nello slot:\u003c\/strong\u003e inserire il modulo in uno slot dedicato all'interno della base terminale FieldMonitor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCablaggio dei trasduttori:\u003c\/strong\u003e collegare i trasduttori di velocità a 2 fili ai terminali del Canale A e del Canale B secondo gli schemi di cablaggio del sistema.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtezione ambientale:\u003c\/strong\u003e assicurarsi che i connettori di campo siano correttamente accoppiati e sigillati per proteggerli dalla condensa dovuta all'umidità.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConformità e certificazioni\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovazioni per aree pericolose:\u003c\/strong\u003e Divisione 2 \/ Zona 2\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666572079467,"sku":"170180-02-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-170180-02-00-i-o-module-ut2add03j3v_3874aae8-bbff-4f32-8519-f25e14f1a52d.jpg?v=1765440859"},{"product_id":"bently-nevada-172109-01-3500-65-16-channel-temperature-monitor-i-o-module","title":"Bently Nevada 172109-01 3500\/65 Modulo I\/O per monitoraggio della temperatura a 16 canali","description":"\u003ch3\u003eDescrizione\u003c\/h3\u003e\n\u003cp\u003eIl \u003cstrong\u003eBently Nevada 172109-01\u003c\/strong\u003e è un modulo I\/O posteriore a tutta altezza progettato per l'uso con il \u003cstrong\u003emonitor di temperatura a 16 canali 3500\/65\u003c\/strong\u003e all'interno del sistema di protezione delle macchine 3500. Il \u003cstrong\u003e172109-01\u003c\/strong\u003e fornisce collegamenti di interfaccia per la terminazione esterna e consente di accettare fino a 16 ingressi di trasduttori di temperatura, supportando sia gli ingressi sul campo di rilevatori di temperatura a resistenza (RTD) sia quelli di termocoppie a punta isolata (TC). Condiziona i segnali dei trasduttori di temperatura e li trasmette alla scheda principale 3500\/65 per il confronto con gli allarmi e il monitoraggio dello stato delle macchine in applicazioni industriali.\u003c\/p\u003e\n\u003ch3\u003eCaratteristiche\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDesign con terminazione esterna per instradare gli ingressi sul campo tramite blocchi e cavi di terminazione esterni\u003c\/li\u003e\n\u003cli\u003eAccetta da 1 a 16 segnali RTD o termocoppie a punta isolata\u003c\/li\u003e\n\u003cli\u003eCompatibilità diretta con la scheda principale del monitor di temperatura a 16 canali 3500\/65\u003c\/li\u003e\n\u003cli\u003eIngombro di uno slot posteriore a tutta altezza nelle configurazioni rack 3500 standard e con paratia\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplicazioni\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMonitoraggio multicanale della temperatura per macchinari rotanti industriali\u003c\/li\u003e\n\u003cli\u003eRilevamento della temperatura di cuscinetti, statori e avvolgimenti in turbine, motori e generatori\u003c\/li\u003e\n\u003cli\u003eIntegrazione del sistema di protezione delle macchine nei rack Bently Nevada 3500\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInformazioni per l'ordine\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eNumero di parte\u003c\/th\u003e\n\u003cth\u003eDescrizione\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e172109-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModulo I\/O RTD\/TC a punta isolata 3500\/65, terminazioni esterne\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e172115-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBlocco di terminazione esterno RTD\/TC a punta isolata (connettori in stile europeo)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e134544-AAAA-BB\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCavo dal segnale del trasduttore (XDCR) 3500\/65 al blocco di terminazione esterno (ET)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eSpecifiche tecniche\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCategoria del parametro\u003c\/th\u003e\n\u003cth\u003eDettagli delle specifiche\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduttore\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumero di parte\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e172109-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIngressi di segnale\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAccetta da 1 a 16 segnali di trasduttori RTD o TC a punta isolata\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTipi di trasduttori supportati (TC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTipo E (da -100 °C a +1000 °C); Tipo J (da 0 °C a +760 °C); Tipo K (da 0 °C a +1370 °C); Tipo T (da -160 °C a +400 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTipi di trasduttori supportati (RTD)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlatino da 100 Ohm a 3 e 4 fili (alfa = 0,00385) (da -200 °C a +850 °C); platino da 100 Ohm a 3 e 4 fili (alfa = 0,00392) (da -200 °C a +700 °C); nichel da 120 Ohm a 3 e 4 fili (da -80 °C a +260 °C); rame da 10 Ohm a 3 e 4 fili (da -100 °C a +260 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImpedenza d'ingresso\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMaggiore di 1 MOhm per ciascun ingresso del conduttore\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrecisione\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRack a paratia: +\/-3 °C a +25 °C; rack standard: +\/-3 °C a +25 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompensazione della giunzione fredda\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/-2 °C a +25 °C (utilizzato per le misurazioni TC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRisoluzione\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 °C o 1 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSorgente di corrente RTD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e913 +\/- 7 uA a +25 °C per trasduttore\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConsumo energetico\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 watt nominali\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRequisiti di spazio nel rack\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 slot posteriore a piena altezza\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensioni (A x L x P)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241,3 mm x 24,4 mm x 99,1 mm (9,50 in x 0,96 in x 3,90 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePeso\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0,45 kg (1,0 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperatura di esercizio\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 °C a +65 °C (-22 °F a +150 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperatura di stoccaggio\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 °C a +85 °C (-40 °F a +185 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eLinee guida per l'installazione\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePosizionamento nello slot:\u003c\/strong\u003e installare il modello 172109-01 in uno slot posteriore a piena altezza direttamente dietro la posizione del modulo principale 3500\/65.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCablaggio dei cavi e delle terminazioni:\u003c\/strong\u003e collegare il modulo I\/O al blocco di terminazione esterno 172115-01 utilizzando cavi 134544 approvati.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRequisiti del firmware:\u003c\/strong\u003e assicurarsi della compatibilità del firmware del sistema (3500\/22 Revisione 1.50 o successiva, 3500\/01 Versione software 3.85 o successiva). Quando si sostituiscono moduli I\/O meno recenti con la revisione 172109-01 Rev D o successiva, aggiornare il firmware del monitor dopo aver rimosso il modulo per evitare errori di mancata corrispondenza.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatibilità delle terminazioni:\u003c\/strong\u003e non utilizzare blocchi di terminazione esterni con moduli I\/O interni di terminazione.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConformità e certificazioni\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFCC:\u003c\/strong\u003e Conforme alla Parte 15 delle norme FCC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDirettive EMC:\u003c\/strong\u003e Direttiva della Comunità europea 2014\/30\/UE; EN 61000-6-2, EN 61000-6-4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSicurezza elettrica:\u003c\/strong\u003e Direttiva della Comunità europea 2014\/35\/UE; EN 61010-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConformità ambientale:\u003c\/strong\u003e Direttiva RoHS 2011\/65\/UE; designazione EFUP China RoHS di 15 anni ai sensi della norma SJ\/T 11364-2024\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovazioni per aree pericolose:\u003c\/strong\u003e cNRTLus Classe I, Zona 2: AEx\/Ex nA nC ic IIC T4 Gc; Classe I, Zona 2: AEx\/Ex ec nC ic IIC T4 Gc; Classe I, Divisione 2, Gruppi A, B, C e D (T4 a Ta = da -20 °C a +65 °C); ATEX\/IECEx Ex II 3 G, Ex nA nC ic IIC T4 Gc, Ex ec nC ic IIC T4 Gc (T4 a Ta = da -20 °C a +65 °C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovazioni marittime:\u003c\/strong\u003e ABS-Marine e applicazioni offshore; Regole DNV GL per la classificazione (navi, unità offshore e imbarcazioni ad alta velocità e leggere)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666618806635,"sku":"172109-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-172109-01-isolated-tip-tc-i-o-module-jf0abonx0vd_05f8cff5-294e-4930-802c-36513e693d70.jpg?v=1765444229"},{"product_id":"bently-nevada-114m5335-01-3500-15-low-voltage-dc-power-input-module","title":"Bently Nevada 114M5335-01 3500\/15 Modulo di ingresso dell'alimentazione CC a bassa tensione","description":"\u003ch3\u003eDescrizione\u003c\/h3\u003e\n\u003cp\u003eIl modulo di ingresso dell'alimentazione CC a bassa tensione (PIM) \u003cstrong\u003e114M5335-01\u003c\/strong\u003e è un modulo di interfaccia dell'alimentazione dedicato, con montaggio posteriore, progettato per il sistema di alimentazione CA e CC \u003cstrong\u003eBently Nevada 3500\/15\u003c\/strong\u003e. Posizionato nello slot posteriore direttamente dietro il modulo di alimentazione frontale associato, \u003cstrong\u003e114M5335-01\u003c\/strong\u003e accetta ingressi di alimentazione CC a bassa tensione e instrada l'alimentazione al modulo di alimentazione CC a bassa tensione \u003cstrong\u003e114M5330-01\u003c\/strong\u003e. Converte l'alimentazione CC a bassa tensione in ingresso nei livelli interni richiesti dal rack del sistema di protezione delle macchine della serie 3500.\u003c\/p\u003e\n\n\u003ch3\u003eCaratteristiche\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAccetta un intervallo di ingresso CC a bassa tensione da 20 Vcc a 30 Vcc.\u003c\/li\u003e\n\u003cli\u003eDesign del modulo dedicato a mezza altezza, installato direttamente dietro il modulo di alimentazione frontale corrispondente.\u003c\/li\u003e\n\u003cli\u003eFunziona in combinazione con il modulo di alimentazione CC a bassa tensione 3500\/15 (\u003cstrong\u003e114M5330-01\u003c\/strong\u003e).\u003c\/li\u003e\n\u003cli\u003eProtezione integrata dalle sovratensioni tramite un fusibile situato sul modulo di ingresso dell'alimentazione.\u003c\/li\u003e\n\u003cli\u003eLa protezione integrata garantisce che le condizioni di sottotensione non causino danni al modulo o all'alimentatore.\u003c\/li\u003e\n\u003cli\u003eSupporta l'inserimento e la rimozione dei moduli senza interruzioni del funzionamento del rack nelle configurazioni di alimentazione a doppia ridondanza.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplicazioni\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRack del sistema di protezione delle macchine della serie 3500 alimentati a CC a bassa tensione.\u003c\/li\u003e\n\u003cli\u003eSistemi industriali di monitoraggio delle condizioni e protezione dei turbomacchinari.\u003c\/li\u003e\n\u003cli\u003eApplicazioni di protezione di macchinari critici in impianti di processo, energetici e produttivi.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eSpecifiche tecniche\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParametro\u003c\/th\u003e\n\u003cth\u003eSpecifica\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduttore\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada \/ Baker Hughes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCodice modello\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e114M5335-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTipo di modulo\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModulo di ingresso dell'alimentazione CC a bassa tensione (PIM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatibilità del sistema\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSistema di alimentazione 3500\/15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIntervallo di tensione in ingresso\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDa 20 a 30 Vcc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCorrente assorbita dal rack completo\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11,0 A massimo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtezione dalle sovratensioni\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIl fusibile sul PIM si apre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtezione dalle sottotensioni\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLa sottotensione non danneggia l'alimentatore o il PIM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCodice del fusibile di ricambio\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e01720045\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCodice del connettore di ricambio\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e118M0915-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensioni (A x L x P)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120,7 mm x 25,4 mm x 114,3 mm (4,75 pollici x 1,0 pollice x 4,5 pollici)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePeso\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0,34 kg (0,75 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperatura di esercizio\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDa -30 degC a +65 degC (da -22 degF a +150 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperatura di stoccaggio\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDa -40 degC a +85 degC (da -40 degF a +185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUmidità\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95%, senza condensa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eLinee guida per l'installazione\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePosizione di montaggio nel rack:\u003c\/strong\u003e Montare il modulo nello speciale slot posteriore a mezza altezza situato direttamente dietro il modulo di alimentazione CC a bassa tensione 3500\/15 associato.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunzionamento ridondante:\u003c\/strong\u003e Nelle configurazioni rack con doppio alimentatore, l'inserimento o la rimozione di uno dei due moduli di alimentazione non interrompe il funzionamento del rack, purché sia attivo un alimentatore secondario.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSicurezza della tensione e del cablaggio:\u003c\/strong\u003e Assicurarsi che le linee di alimentazione CC rispettino l'intervallo operativo nominale da 20 a 30 Vcc e verificare la corretta polarità dei terminali durante il cablaggio.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManutenzione del fusibile:\u003c\/strong\u003e Se una condizione di sovratensione causa l'apertura del fusibile del modulo, sostituirlo utilizzando il fusibile di ricambio verificato con codice \u003cstrong\u003e01720045\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eConformità e certificazioni\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFCC:\u003c\/strong\u003e Parte 15 Classe A.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDirettive EMC:\u003c\/strong\u003e Direttiva della Comunità Europea 2014\/30\/UE; EN 61000-6-2; EN 61000-6-4.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSicurezza elettrica:\u003c\/strong\u003e Direttiva della Comunità Europea 2014\/35\/UE; EN 61010-1.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Direttiva della Comunità Europea 2011\/65\/UE.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovazioni marittime:\u003c\/strong\u003e Regole DNV GL per la classificazione; Regole ABS per le condizioni di classificazione.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovazioni per aree pericolose:\u003c\/strong\u003e Classe I, Zona 2: AEx\/Ex nA nC ic IIC T4 Gc; AEx\/Ex ec nC ic IIC T4 Gc; Classe I, Divisione 2, Gruppi A, B, C e D (T4 a Ta = da -20 degC a +65 degC).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX \/ IECEx:\u003c\/strong\u003e Ex II 3 G; Ex nA nC ic IIC T4 Gc; Ex ec nC ic IIC T4 Gc (T4 a Ta = da -20 degC a +65 degC).\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666741227883,"sku":"114M5335-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-114m5335-01-power-supply-module-2m3l2m0mdz5_dfcfc754-bbf4-4660-8411-84020b5ca875.jpg?v=1765446865"},{"product_id":"bently-nevada-139554-01-3500-45-ac-lvdt-position-i-o-module","title":"Bently Nevada 139554-01 3500\/45 Modulo I\/O di posizione LVDT CA","description":"\u003ch3\u003eDescrizione\u003c\/h3\u003e\n\u003cp\u003eIl \u003cstrong\u003eBently Nevada 139554-01\u003c\/strong\u003e è un modulo I\/O di posizione LVDT CA con terminazioni interne, progettato per applicazioni di monitoraggio e protezione della posizione dei macchinari. Installato in uno slot posteriore a tutta altezza di un rack del sistema Bently Nevada 3500, il modulo instrada i segnali di ingresso dai trasformatori differenziali lineari variabili CA (LVDT CA) direttamente alla scheda principale del monitor di posizione \u003cstrong\u003e3500\/45\u003c\/strong\u003e. Fornisce un'eccitazione continua del trasduttore mediante un segnale a onda sinusoidale da 2,3 Vrms a 3400 Hz e supporta parametri chiave tra cui le misurazioni dell'espansione della carcassa e della posizione della valvola. Le interfacce di processo dispongono di uscite di corrente per registratore da +4 a +20 mA per l'integrazione con il controllo locale e di ingressi di controllo dell'inibizione dedicati.\u003c\/p\u003e\n\u003ch3\u003eCaratteristiche\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAccetta fino a 4 ingressi di segnale da trasduttori LVDT CA tramite collegamenti ai terminali interni.\u003c\/li\u003e\n\u003cli\u003eFornisce un'alimentazione dedicata per l'eccitazione del trasduttore con onda sinusoidale da 2,3 Vrms a 3400 Hz.\u003c\/li\u003e\n\u003cli\u003eDispone di uscite di corrente proporzionali da +4 a +20 mA per la trasmissione dei dati al registratore.\u003c\/li\u003e\n\u003cli\u003eInclude i pin dei terminali di inibizione hardware (INHB) e di ritorno per il controllo remoto delle funzioni.\u003c\/li\u003e\n\u003cli\u003eIntegra morsettiere interne a vite direttamente nell'interfaccia posteriore del modulo.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplicazioni\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMonitoraggio dell'espansione della carcassa nelle carcasse delle turbine a vapore.\u003c\/li\u003e\n\u003cli\u003eMonitoraggio della posizione delle valvole per gli steli delle valvole di ingresso del processo e le valvole di controllo del regolatore.\u003c\/li\u003e\n\u003cli\u003eMonitoraggio continuo della posizione nei sistemi di protezione dei macchinari rotanti.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInformazioni per l'ordine\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCodice articolo \/ Opzione\u003c\/th\u003e\n\u003cth\u003eDescrizione\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/45-AA-BB\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMonitor di posizione\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpzione A: 05\u003c\/td\u003e\n\u003ctd\u003eModulo I\/O di posizione LVDT CA con terminazioni interne\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRicambi\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e139554-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eModulo I\/O di posizione LVDT CA con terminazioni interne per l'uso con LVDT CA\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSpecifiche tecniche\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParametro\u003c\/th\u003e\n\u003cth\u003eSpecifiche\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduttore\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModello\u003c\/td\u003e\n\u003ctd\u003e139554-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTipo di modulo\u003c\/td\u003e\n\u003ctd\u003eModulo I\/O di posizione LVDT CA con terminazioni interne\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModulo principale compatibile\u003c\/td\u003e\n\u003ctd\u003eMonitor di posizione 3500\/45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCanali di ingresso\u003c\/td\u003e\n\u003ctd\u003eAccetta da 1 a 4 ingressi di segnale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpedenza d'ingresso\u003c\/td\u003e\n\u003ctd\u003e137 kOhm (ingressi LVDT CA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlimentazione del trasduttore\u003c\/td\u003e\n\u003ctd\u003e2,3 Vrms, onda sinusoidale a 3400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConsumo energetico del sistema\u003c\/td\u003e\n\u003ctd\u003e8,5 watt tipici (utilizzando l'I\/O LVDT CA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUscite per registratore\u003c\/td\u003e\n\u003ctd\u003eDa +4 a +20 mA (proporzionale al fondo scala)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConformità della tensione\u003c\/td\u003e\n\u003ctd\u003e0 to +12 Vdc across load (Load resistance: 0 to 600 Ohm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDa 0 a +12 Vcc sul carico (resistenza del carico: da 0 a 600 Ohm)\u003c\/td\u003e\n\u003ctd\u003eTemperatura operativa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-30 °C a +65 °C (-22 °F a +150 °F)\u003c\/td\u003e\n\u003ctd\u003eTemperatura di stoccaggio\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-40 °C a +85 °C (-40 °F a +185 °F)\u003c\/td\u003e\n\u003ctd\u003eUmidità operativa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e95% senza condensa\u003c\/td\u003e\n\u003ctd\u003eDimensioni (A x L x P)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e241,3 mm x 24,4 mm x 99,1 mm (9,50 in x 0,96 in x 3,90 in)\u003c\/td\u003e\n\u003ctd\u003ePeso\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0,20 kg (0,44 lb)\u003c\/td\u003e\n\u003ctd\u003eRequisiti di spazio nel rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e1 slot posteriore ad altezza intera\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCollegamenti\/interfacce\u003c\/th\u003e\n\u003cth\u003ePin del morsetto\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunzione\u003c\/td\u003e\n\u003ctd\u003eCH1 LVDT (1, 2, 3, 4, 5, 6, SHLD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminali di ingresso e schermatura LVDT CA del canale 1\u003c\/td\u003e\n\u003ctd\u003eCH2 LVDT (1, 2, 3, 4, 5, 6, SHLD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminali di ingresso e schermatura LVDT CA del canale 2\u003c\/td\u003e\n\u003ctd\u003eCH3 LVDT (1, 2, 3, 4, 5, 6, SHLD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminali di ingresso e schermatura LVDT CA del canale 3\u003c\/td\u003e\n\u003ctd\u003eCH4 LVDT (1, 2, 3, 4, 5, 6, SHLD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminali di ingresso e schermatura LVDT CA del canale 4\u003c\/td\u003e\n\u003ctd\u003eINHB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngresso di controllo dell'inibizione\u003c\/td\u003e\n\u003ctd\u003eRET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCollegamento di ritorno\u003c\/td\u003e\n\u003ctd\u003eCOM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRiferimento comune\u003c\/td\u003e\n\u003ctd\u003eUscita di corrente del registratore del canale 1 (+4 a +20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eREC2\u003c\/td\u003e\n\u003ctd\u003eUscita di corrente del registratore del canale 2 (+4 a +20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eREC3\u003c\/td\u003e\n\u003ctd\u003eUscita di corrente del registratore del canale 3 (+4 a +20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eREC4\u003c\/td\u003e\n\u003ctd\u003eUscita di corrente del registratore del canale 4 (+4 a +20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSCHERMATURA\u003c\/td\u003e\n\u003ctd\u003eCollegamento della messa a terra dello chassis del sistema\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eLinee guida per l'installazione\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstallare il modulo nello slot posteriore ad altezza intera direttamente dietro la scheda principale del monitor di posizione 3500\/45.\u003c\/li\u003e\n\u003cli\u003eSerrare le viti prigioniere superiore e inferiore per mantenere una corretta messa a terra dello chassis e l'integrità meccanica.\u003c\/li\u003e\n\u003cli\u003eInstradare i cavi di segnale del trasduttore attraverso i morsettiere interne, con un adeguato scarico della trazione.\u003c\/li\u003e\n\u003cli\u003eCollegare i cavi schermati direttamente ai punti terminali SHLD designati per ridurre al minimo le interferenze elettromagnetiche.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConformità e certificazioni\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDirettive EMC: Direttiva della Comunità Europea 2014\/30\/UE; EN 61000-6-2, EN 61000-6-4\u003c\/li\u003e\n\u003cli\u003eSicurezza elettrica: Direttiva della Comunità Europea 2014\/35\/UE; EN 61010-1\u003c\/li\u003e\n\u003cli\u003eDirettive RoHS: Direttiva ROHS della Comunità Europea 2011\/65\/UE; China RoHS SJ\/T 11364-2024 (EFUP 15 anni)\u003c\/li\u003e\n\u003cli\u003eOmologazioni marittime: norme DNV GL per la classificazione; norme ABS per le condizioni di classificazione\u003c\/li\u003e\n\u003cli\u003eOmologazioni per aree pericolose: cNRTLus Classe I, Zona 2 \/ Classe I, Divisione 2, Gruppi A, B, C, D (T4 a Ta = -20 °C a +65 °C); ATEX\/IECEx Ex nA nC ic IIC T4 Gc \/ Ex ec nC ic IIC T4 Gc\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666767147371,"sku":"139554-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-139554-01-lvdt-position-i-o-module-fagye0bi2in_151afe44-c8ef-487a-864e-a372b314383c.jpg?v=1765447223"},{"product_id":"bently-nevada-125840-02-3500-15-low-voltage-ac-power-input-module","title":"Bently Nevada 125840-02 Modulo di ingresso dell'alimentazione CA a bassa tensione 3500\/15","description":"\u003ch3\u003eDescrizione\u003c\/h3\u003e\n\u003cp\u003eIl \u003cstrong\u003eBently Nevada 125840-02\u003c\/strong\u003e è un \u003cstrong\u003emodulo di ingresso dell'alimentazione CA a bassa tensione\u003c\/strong\u003e progettato per accettare l'alimentazione di rete CA esterna a bassa tensione e interfacciarsi direttamente con il modulo di alimentazione CA 3500\/15 nel sistema di protezione dei macchinari 3500. Operando come modulo a mezza altezza posizionato nello slot posteriore speciale direttamente dietro l'alimentatore installato anteriormente associato, il \u003cstrong\u003e125840-02\u003c\/strong\u003e riceve la tensione di rete, la fa passare attraverso un fusibile sostitutivo integrato e convoglia l'alimentazione condizionata al sistema rack 3500. Supporta un ingresso nominale di 110 V CA con un intervallo operativo da 85 a 132 V CA RMS (e da 85 a 125 V CA RMS per le revisioni PIM precedenti alla Rev. R abbinate a moduli di alimentazione CA precedenti alla Rev. M) per alimentare un rack completo senza richiedere un carico minimo del rack.\u003c\/p\u003e\n\u003ch3\u003eCaratteristiche\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMontaggio speciale del modulo posteriore a mezza altezza, posizionato direttamente dietro il modulo di alimentazione anteriore associato\u003c\/li\u003e\n\u003cli\u003eProtezione tramite fusibile integrato, con fusibile sostitutivo numero di parte 01720025\u003c\/li\u003e\n\u003cli\u003eAccetta una tensione di ingresso nominale di 110 V CA su un intervallo operativo da 85 a 132 V CA RMS\u003c\/li\u003e\n\u003cli\u003eAccetta una frequenza della linea di ingresso da 47 a 63 Hz\u003c\/li\u003e\n\u003cli\u003eSupporta configurazioni di alimentazione primaria o ridondante negli appositi slot sul lato sinistro del rack\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplicazioni\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInterfaccia di ingresso dell'alimentazione per i sistemi di protezione dei macchinari Bently Nevada della serie 3500\u003c\/li\u003e\n\u003cli\u003eCollegamento all'alimentazione di rete CA a bassa tensione per i moduli di alimentazione CA 3500\/15\u003c\/li\u003e\n\u003cli\u003eInstallazioni per il monitoraggio delle condizioni di macchinari rotanti e turbomacchinari che richiedono un'alimentazione di campo a 110 V CA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInformazioni per l'ordine\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eNumero di parte\u003c\/th\u003e\n\u003cth\u003eDescrizione\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e125840-02\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModulo di ingresso dell'alimentazione CA a bassa tensione\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e127610-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModulo di alimentazione CA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e01720025\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFusibile sostitutivo (per i moduli di ingresso dell'alimentazione CA e i moduli di ingresso dell'alimentazione CC ad alta tensione)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSpecifiche tecniche\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParametro\u003c\/th\u003e\n\u003cth\u003eSpecifiche\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduttore\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada \/ GE Measurement \u0026amp; Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumero di parte\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125840-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTipo di modulo\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModulo legacy di ingresso dell'alimentazione CA a bassa tensione (PIM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTensione di ingresso nominale\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110 V CA nominali\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIntervallo della tensione di ingresso\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDa 85 a 132 Vac rms (da 120 a 188 Vac pk)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIntervallo di tensione legacy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDa 85 a 125 Vac rms (per PIM precedente alla revisione R \/ alimentatore precedente alla revisione M)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequenza di ingresso\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDa 47 a 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAssorbimento di corrente del rack completo\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.5 A rms (massimo)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtezione fuori intervallo\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLa sottotensione non danneggia il PIM; la sovratensione provoca l'apertura del fusibile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCodice del fusibile di ricambio\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e01720025\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensioni (A x L x P)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120.7 mm x 25.4 mm x 114.3 mm (4.75 in x 1.0 in x 4.5 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePeso\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.34 kg (0.75 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperatura di esercizio\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 degC a +65 degC (-22 degF a +150 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperatura di stoccaggio\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 degC a +85 degC (-40 degF a +185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUmidità\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95%, senza condensa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eCollegamenti\/Interfacce\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eIdentificativo della morsettiera\u003c\/th\u003e\n\u003cth\u003eFunzione\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eLN1\u003c\/td\u003e\n\u003ctd\u003eCollegamento di ingresso linea 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLN2 \/ NEUT\u003c\/td\u003e\n\u003ctd\u003eCollegamento di ingresso linea 2 \/ neutro\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGND\u003c\/td\u003e\n\u003ctd\u003eMorsetto di terra di protezione\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eLinee guida per l'installazione\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstallare il modulo nell'apposito slot posteriore a mezza altezza, situato direttamente dietro il modulo di alimentazione anteriore 3500\/15 associato.\u003c\/li\u003e\n\u003cli\u003eFissare il cablaggio di ingresso sul campo ai morsetti a vite LN1, LN2\/NEUT e GND designati sulla morsettiera posteriore.\u003c\/li\u003e\n\u003cli\u003eVerificare che la tensione di campo sia disinserita prima di installare o rimuovere il cablaggio di ingresso e il gruppo morsettiera.\u003c\/li\u003e\n\u003cli\u003eAssicurarsi di inserire correttamente il fusibile di ricambio 01720025 specificato nel portafusibile PIM.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConformità e certificazioni\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNorme EMC:\u003c\/strong\u003e EN 61000-6-2 (Immunità per ambienti industriali), EN 61000-6-4 (Emissioni per ambienti industriali)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDirettiva EMC:\u003c\/strong\u003e Direttiva della Comunità Europea 2014\/30\/UE\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNorma di sicurezza elettrica:\u003c\/strong\u003e EN 61010-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDirettiva sulla bassa tensione:\u003c\/strong\u003e Direttiva della Comunità Europea 2014\/35\/UE\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA \/ NRTL\/C (Opzione di approvazione 01):\u003c\/strong\u003e Classe I, Divisione 2, Gruppi A, B, C, D; Classe I, Zona 2; Ex nC [L] IIC T4 Gc \/ AEx nC IIC T4 Gc (T4 a Ta = -20 degC a +65 degC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX \/ IECEx (Opzione di approvazione 02):\u003c\/strong\u003e II 3 G, Ex nA nC ic IIC T4 Gc (T4 a Ta = -20 degC a +65 degC)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666846544235,"sku":"125840-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-125840-02-low-voltage-ac-power-input-module-bsopui1o5vn_18aa0739-9677-4d2f-afbc-767e639ec61a.jpg?v=1765448934"},{"product_id":"bently-nevada-135473-01-3500-25-keyphasor-i-o-module-internal-barriers","title":"Bently Nevada 135473-01 3500\/25 modulo I\/O Keyphasor (barriere interne)","description":"\u003ch3\u003ePanoramica del prodotto\u003c\/h3\u003e\n\u003cp\u003eIl \u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e135473-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e di Bently Nevada è un modulo I\/O specializzato a mezza altezza, progettato per il sistema Keyphasor avanzato \u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/25\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e. Questa configurazione specifica integra \u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ebarriere interne\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e e \u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eterminazioni interne\u003c\/strong\u003e, fornendo un'interfaccia di sicurezza intrinseca basata su hardware per i trasduttori situati in aree pericolose. Il modulo è progettato per ricevere ed elaborare segnali a impulsi una volta per giro o più volte per giro provenienti da sonde di prossimità o pickup magnetici, essenziali per calcolare la velocità di rotazione della macchina e fornire un riferimento di fase per l'analisi delle vibrazioni.\u003c\/p\u003e\n\u003cp\u003eIl\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e135473-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunge da interfaccia fisica all'interno del rack 3500, garantendo l'isolamento elettrico e il condizionamento del segnale per la protezione di macchinari critici. Sebbene il modulo supporti le misurazioni di fase, è ottimizzato per il monitoraggio ad alta precisione della velocità dell'albero. Utilizzando la versione con barriera interna, il modulo fornisce un punto di connessione sicuro che limita l'energia elettrica inviata ai sensori sul campo, in conformità con i rigorosi standard di sicurezza industriale per le atmosfere esplosive.\u003c\/p\u003e\n\u003ch3\u003eConfigurazione tecnica\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttributo\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecifiche\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModello\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e135473-01\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMarca\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTipo di prodotto\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModulo I\/O Keyphasor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSerie\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSerie 3500\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTipo di terminazione\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTerminazioni interne\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInterfaccia di sicurezza\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBarriere interne (tipo Zener)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCanali di ingresso\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 segnali del trasduttore (di prossimità o pickup magnetico)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConsumo energetico\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3,2 Watt tipici\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eImpedenza di ingresso\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e21,8 kΩ minimo\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIntervallo del segnale (non isolato)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDa +0,8 V a -21,0 V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVelocità minima del pickup magnetico\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026gt; 200 giri\/min (3,3 Hz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensioni (A x L x P)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e241,3 mm x 24,4 mm x 103,1 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensioni (A x L x P)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0,46 kg (1,01 lb)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTemperatura di esercizio\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDa 0 °C a +65 °C (da 32 °F a +150 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTemperatura di stoccaggio\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDa -40 °C a +85 °C (da -40 °F a +185 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eUmidità\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e95% senza condensa\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInformazioni per l'ordine\u003c\/h3\u003e\n\u003cp\u003eGli approvvigionamenti industriali dovrebbero concentrarsi sul numero di parte specifico per garantire la compatibilità con la configurazione del monitor 3500\/25.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNumero di parte\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e135473-01\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDescrizione\u003c\/strong\u003e: Modulo I\/O Keyphasor con barriere interne e terminazioni interne\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCondizione\u003c\/strong\u003e: Nuovo originale\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDisponibilità\u003c\/strong\u003e: Scorte di ricambi\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDomande frequenti\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQuesto modulo può fornire isolamento per le applicazioni Proximitor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSì, è compatibile con le applicazioni Proximitor, ma richiede un alimentatore esterno per fornire l'isolamento.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQual è l'obiettivo progettuale principale della versione I\/O isolata?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eÈ stato progettato specificamente per applicazioni con pickup magnetici in cui i segnali sono collegati in parallelo a più dispositivi, come i sistemi di controllo.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCosa succede se i segnali di ingresso superano l'intervallo specificato?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eI segnali che superano l'intervallo di tensione specificato vengono limitati internamente dai circuiti del modulo.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRiferimento tecnico: cablaggio, ponticelli e specifiche\u003c\/h3\u003e\n\u003ch3\u003e1. CABLAGGIO DEI CANALI E DEFINIZIONI DEI PIN\u003c\/h3\u003e\n\u003cp\u003eIl\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e135473-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eè un modulo I\/O con terminazione interna e barriere galvaniche integrate. Dispone di due morsettiere indipendenti per il Canale 1 e il Canale 2.\u003c\/p\u003e\n\u003ch4\u003eA. Cablaggio della sonda di prossimità (a 3 fili)\u003c\/h4\u003e\n\u003cp\u003ePer i sensori a correnti parassite standard (ad es. serie 3300 XL):\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePWR (-24 V):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUscita di alimentazione per il Proximitor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCOM (GND):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eComune\/ritorno del segnale.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSIG (OUT):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIngresso per il segnale di tensione a impulsi.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eB. Cablaggio del pickup magnetico (passivo a 2 fili)\u003c\/h4\u003e\n\u003cp\u003ePer i sensori elettromagnetici di velocità autogeneranti:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSIG:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCollegare al conduttore positivo (+) del sensore.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCOM:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCollegare al conduttore negativo (-) del sensore.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePWR:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDeve rimanere scollegato (flottante).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eC. Schermatura e messa a terra IS\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSHLD (Schermatura):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCollegare le schermature dei cavi di campo a questo morsetto dedicato.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTerra IS:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eQuesto modulo deve essere collegato a terra tramite il\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e136719-01 Barrier Earth Module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ea una barra di terra dedicata alla sicurezza intrinseca, per garantire l’integrità antideflagrante.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e2. CONFIGURAZIONI DEI PONTICELLI HARDWARE\u003c\/h3\u003e\n\u003cp\u003eI ponticelli si trovano sulla scheda elettronica interna e devono essere impostati prima dell’installazione.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eTipo di trasduttore\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003ePonticello di alimentazione del trasduttore\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003ePonticello di accoppiamento dell’ingresso\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eFunzione logica\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSonda di prossimità\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eINT\u003c\/strong\u003e (Interno)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCC\u003c\/strong\u003e (Corrente continua)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFornisce alimentazione; consente la polarizzazione CC.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePickup magnetico\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEXT\u003c\/strong\u003e (Esterno\/OFF)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCA\u003c\/strong\u003e (Corrente alternata)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eInterrompe l’alimentazione; filtra il rumore CC.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cblockquote\u003e\n\u003cp\u003e\u003cstrong\u003eIMPORTANTE:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDisalimentare sempre il rack 3500 o rimuovere il modulo monitor prima di regolare i ponticelli, per evitare archi elettrici.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003chr\u003e\n\u003ch3\u003e3. SPECIFICHE PRESTAZIONALI PRINCIPALI\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCapacità dei canali:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2 canali d’ingresso indipendenti.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntervallo di frequenza:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eda 1 a 1.200.000 cpm (\u003cstrong\u003eda 0,017 Hz a 20 kHz\u003c\/strong\u003e).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntervallo di tensione d’ingresso:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eda +5 V a -11 V\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(specificamente per Barrier I\/O).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModalità di condizionamento:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSoglia automatica:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSegnale minimo 2 V picco-picco; velocità minima 120 rpm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSoglia manuale:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRegolabile da 0 a -20 Vcc; segnale minimo 500 mV; supporta velocità ridotte fino a 1 rpm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCondizioni ambientali:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eConsumo energetico:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3,2 Watt\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(tipico).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTemperatura di esercizio:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eda 0 °C a 65 °C\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e4. CERTIFICAZIONI PER AREE PERICOLOSE\u003c\/h3\u003e\n\u003cp\u003eProgettato per ambienti ad alto rischio:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNord America:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eClasse I, Div 2, Gruppi A, B, C, D.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEuropa (ATEX):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eII 1 G [EEx ia] IIC (ingressi classificati per la Zona 0).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e5. SUPPORTO ALLA CONFIGURAZIONE DEL SISTEMA\u003c\/h3\u003e\n\u003cp\u003eDopo l'installazione fisica, usa il\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esoftware di configurazione del rack 3500\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eper verificare:\u003c\/p\u003e\n\u003col class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eImpostazioni dell'isteresi:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eper evitare attivazioni errate con segnali disturbati.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOrientamento:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eimposta la direzione dell'impulso (positiva\/negativa).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCanali attivi:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003everifica che il software corrisponda alle impostazioni fisiche dei ponticelli.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003ePARTE 2: SCHEMI DEI TERMINALI E CONFIGURAZIONE DEL SOFTWARE\u003c\/h3\u003e\n\u003ch3\u003e1. DISPOSIZIONE DEI PIN DELLA MORSETTIERA (A\/B\/C\/D)\u003c\/h3\u003e\n\u003cp\u003eIl\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e135473-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eutilizza una sequenza specifica di 4 terminali per ciascun canale. Di seguito è riportata la mappatura per il collegamento del cablaggio di campo:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminale\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eEtichetta\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSonda di prossimità (a 3 fili)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003ePickup magnetico (a 2 fili)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eA\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePWR\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAlimentazione a -24 Vcc (bianco)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNESSUN COLLEGAMENTO\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eB\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCOM\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eComune\/GND (nero)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSegnale negativo (-)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eC\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSIG\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIngresso del segnale (rosso)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSegnale positivo (+)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eD\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSHLD\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCavo di schermatura\/di scarico\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCavo di schermatura\/di scarico\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003e2. CONFIGURAZIONE DEL SOFTWARE (CONFIGURAZIONE DEL RACK 3500)\u003c\/h3\u003e\n\u003cp\u003eDopo aver installato l'hardware, è necessario configurare quanto segue nell'utility software:\u003c\/p\u003e\n\u003ch4\u003eA. Impostazioni della soglia\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSoglia automatica\u003c\/strong\u003e:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eIl sistema calcola automaticamente il punto di attivazione al 50% dell'ampiezza del segnale.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIdeale per\u003c\/strong\u003e: velocità operative standard (\u0026gt;120 giri\/min) con impulsi puliti e uniformi.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSoglia manuale\u003c\/strong\u003e:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eImposti manualmente una tensione fissa (ad esempio, -8,0 Vcc).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIdeale per\u003c\/strong\u003e: avviamenti a bassa velocità o segnali con notevoli \"glitch\" o rumore.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuggerimento per il calcolo\u003c\/strong\u003e: imposta la soglia sul punto intermedio tra il picco dell'impulso e il segnale di base.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eB. Isteresi (riduzione del rumore)\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePer i\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epickup magnetici\u003c\/strong\u003e, è necessario impostare un valore di isteresi (in genere\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eda 0,2 V a 0,5 V\u003c\/strong\u003e) per evitare che il monitor si attivi due volte se il segnale è disturbato mentre attraversa la soglia.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eC. Fronte attivo (direzione)\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFronte negativo\u003c\/strong\u003e: si attiva quando il segnale passa da 0 V a -24 V (standard per la maggior parte delle sonde Bently).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFronte positivo\u003c\/strong\u003e: si attiva quando il segnale si muove in direzione positiva.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e3. ELENCO DI CONTROLLO CRITICO PER L'INSTALLAZIONE\u003c\/h3\u003e\n\u003col class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMessa a terra della barriera\u003c\/strong\u003e: assicurati che il modulo\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e136719-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esia installato nel rack. In caso contrario, il modulo 135473-01 non può mettere correttamente a terra le barriere di sicurezza interne.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVerifica dei ponticelli\u003c\/strong\u003e: controlla attentamente che i ponticelli di\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCanale 1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ee\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCanale 2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecorrispondano ai rispettivi sensori. Un errore comune consiste nel lasciare il ponticello PWR su\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eINT\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003equando si utilizza un pickup magnetico, il che può provocare rumore o surriscaldamento.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCodifica\u003c\/strong\u003e: usa\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edeg C\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ee\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCelsius\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003enella documentazione tecnica per evitare i problemi di caratteri corrotti riscontrati in precedenza nel tuo CMS.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666847134059,"sku":"135473-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-135473-01-motion-controller-module-with-316l-stainless-steel-case-material-ag55zssqu3e_fe8b3db7-fd2e-41ca-ad85-8851d4d47e88.jpg?v=1765448946"},{"product_id":"bently-nevada-81546-01-xdcr-i-o-and-record-terminals","title":"Bently Nevada 81546-01 XDCR terminali I\/O e di registrazione","description":"\u003ch3\u003eDescrizione\u003c\/h3\u003e\n\u003cp\u003eIl \u003cstrong\u003e81546-01\u003c\/strong\u003e Bently Nevada è un \u003cstrong\u003emodulo di ingresso\/uscita del trasduttore e terminale di registrazione\u003c\/strong\u003e industriale ad alta affidabilità, progettato per un'integrazione fluida nei sistemi di monitoraggio delle condizioni dei macchinari rotanti. Questo componente hardware specializzato per la terminazione stabilisce connessioni essenziali del percorso del segnale tra i trasduttori di campo montati sulla carcassa e i monitor centralizzati per la protezione degli asset o le apparecchiature esterne di registrazione dei dati. Il \u003cstrong\u003e81546-01\u003c\/strong\u003e fornisce un instradamento strutturato tramite morsettiera per i segnali grezzi delle sonde di prossimità, dei sensori di velocità o degli accelerometri, fornendo contemporaneamente percorsi indipendenti verso i terminali di registrazione.\u003c\/p\u003e\n\u003cp\u003eFacilitando una terminazione dei cavi organizzata e sicura, protegge le delicate forme d'onda diagnostiche a bassa tensione dal degrado e dall'accoppiamento di rumore capacitivo. Progettato per funzionare in modo affidabile all'interno di involucri per pannelli in ambienti gravosi, il blocco incorpora canaline di isolamento fisico distinte per separare le uscite principali di monitoraggio dalle linee secondarie della strumentazione di registrazione. Il \u003cstrong\u003e-01\u003c\/strong\u003e la designazione dell'opzione specifica la variante hardware standard di base, garantendo una configurazione fissa, assegnazioni dei pin standard e la compatibilità predefinita per il montaggio meccanico con rack specializzati per la protezione dell'impianto.\u003c\/p\u003e\n\u003ch3\u003eCaratteristiche\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eArchitettura di terminazione a doppio scopo che combina percorsi primari di I\/O del trasduttore con derivazioni indipendenti verso i terminali di registrazione.\u003c\/li\u003e\n\u003cli\u003eMorsettiere a vite o a molla che garantiscono connessioni di cablaggio resistenti alle vibrazioni per i conduttori di campo.\u003c\/li\u003e\n\u003cli\u003eChiare canaline di separazione fisica dell'hardware che impediscono la diafonia dei segnali e le interferenze tra i canali.\u003c\/li\u003e\n\u003cli\u003eProfilo di integrazione nel pannello ottimizzato per l'utilizzo dello spazio all'interno degli armadi locali di marshalling.\u003c\/li\u003e\n\u003cli\u003eStruttura fisica per impieghi gravosi, progettata per il funzionamento continuo su skid di bilanciamento dell'impianto soggetti a vibrazioni elevate.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplicazioni\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTerminazione del cablaggio di campo ad alta densità per sonde di prossimità e sensori di carcassa che monitorano turbomacchinari critici.\u003c\/li\u003e\n\u003cli\u003eInstradamento pulito dei segnali diagnostici dai rack di protezione delle macchine verso registratori grafici continui senza carta o ingressi dello storico di impianto.\u003c\/li\u003e\n\u003cli\u003eInstradamento strutturato dei cavi della strumentazione all'interno di involucri centralizzati per la protezione degli asset e delle zone di confine delle aree pericolose.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInformazioni per l'ordinazione\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eDettaglio\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eRiferimento per l'ordinazione del prodotto\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDesignazione del modello base\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e81546 (I\/O del trasduttore e terminali di registrazione)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCodice di assemblaggio completo\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e81546-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBlocco suffisso opzione completo\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-01 (Configurazione standard e opzione di base di montaggio)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSpecifiche tecniche\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParametro\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDettaglio\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduttore\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDesignazione del modello\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e81546-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTipo di prodotto\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModulo I\/O del trasduttore (XDCR) e di terminazione della registrazione\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTipo di connessione del cablaggio\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMorsettiere a vite industriali o strisce con morsetti\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProfilo di compatibilità del segnale\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eForme d'onda dinamiche a bassa tensione di vibrazione, posizione e velocità\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eClasse di isolamento\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSeparazione fisica tra i canali e schermatura delle tracce dei circuiti\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumero di percorsi di registrazione\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConfigurato per derivazioni di uscita di registrazione secondarie indipendenti\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConfigurazione di montaggio\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e01 Piastra di base specifica \/ ingombro del telaio\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProfilo del materiale del telaio\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePolimero industriale ignifugo o piastra posteriore in vetro-epossidica rinforzata\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOttimizzazione della guida hardware\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLayout a basso profilo progettato per array di pannelli di smistamento strutturali\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLimiti della temperatura operativa\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntervallo prestazionale industriale standard, classificato per ambienti con calore confinato nell'involucro\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRiferimento del peso operativo\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePeso del blocco di terminazione industriale standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnessioni\/Interfacce\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eGruppo di morsetti\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eAssegnazione delle funzioni\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIngresso trasduttore (XDCR)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePunti di terminazione per i conduttori grezzi dei sensori di campo (Alimentazione, Segnale, Comune)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePercorso I\/O del monitor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLinee di instradamento dell'uscita dedicate, collegate direttamente al rack principale di protezione\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMorsetti di registrazione\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConnessioni di uscita parallele e isolate per registratori e data logger diagnostici esterni\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSchermo\/Messa a terra\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePunti di messa a terra comuni del telaio per terminare i fili di drenaggio dello schermo dei cavi in ingresso\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eLinee guida per l'installazione\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMontaggio del pannello di smistamento:\u003c\/strong\u003e Fissare saldamente il telaio del blocco di terminazione alla guida interna designata dell'involucro o alla piastra posteriore. Assicurarsi che tutti gli elementi di fissaggio meccanici siano completamente serrati per resistere alle vibrazioni strutturali locali.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCollegamento dei fili del trasduttore:\u003c\/strong\u003e Spellare i conduttori dei sensori in ingresso secondo le specifiche tecniche standard e collegarli ai morsetti XDCR. Serrare saldamente le viti per garantire un contatto elettrico continuo senza schiacciare l'isolamento dei fili.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeparazione delle linee di segnale:\u003c\/strong\u003e Instradare i cavi di registrazione secondari lontano dalle linee dei motori in corrente alternata ad alta tensione o dai relè di commutazione ad alta potenza all'interno del pannello, per eliminare l'iniezione di rumore elettromagnetico.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminazione dei fili di drenaggio dello schermo:\u003c\/strong\u003e Collegare i fili di drenaggio dello schermo dei cavi di strumentazione in ingresso esclusivamente ai punti terminali dello schermo designati, per creare una messa a terra del pannello a punto singolo e prevenire i loop di massa.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666847199595,"sku":"81546-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-81546-01-xdcr-i-o-and-record-terminals-qleh4l44are_5a17253a-6dc8-4d4a-a55e-6f41284e3088.jpg?v=1765448948"},{"product_id":"bently-nevada-129478-01-high-voltage-dc-power-input-module","title":"Bently Nevada 129478-01 modulo di ingresso dell'alimentazione CC ad alta tensione","description":"\u003ch3\u003eDescrizione\u003c\/h3\u003e\n\u003cp\u003eIl \u003cstrong\u003eBently Nevada 129478-01\u003c\/strong\u003e Modulo di ingresso dell’alimentazione CC ad alta tensione (PIM) è un modulo di ingresso dell’alimentazione progettato per la distribuzione dell’alimentazione nei sistemi di protezione dei macchinari. Il modulo è una speciale scheda posteriore a mezza altezza, situata direttamente dietro il modulo di alimentazione CC ad alta tensione \u003cstrong\u003e129486-01\u003c\/strong\u003e associato, all’interno del sistema di alimentazione \u003cstrong\u003e3500\/15\u003c\/strong\u003e. Accetta una tensione di ingresso da 88 a 140 Vcc e instrada l’alimentazione attraverso l’architettura del bus di alimentazione interno del rack, supportando l’hardware di monitoraggio e protezione dei macchinari. Il modulo integra una protezione dell’ingresso tramite fusibile: una condizione di sovratensione provoca l’apertura del fusibile per proteggere i componenti a valle, mentre le condizioni di sottotensione non danneggiano il modulo.\u003c\/p\u003e\n\u003ch3\u003eCaratteristiche\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAccetta un intervallo di tensione di ingresso da 88 a 140 Vcc\u003c\/li\u003e\n\u003cli\u003eSi monta direttamente dietro il modulo di alimentazione associato, in uno slot posteriore a mezza altezza\u003c\/li\u003e\n\u003cli\u003eInclude un sistema integrato di protezione dell’ingresso tramite fusibile contro le sovratensioni\u003c\/li\u003e\n\u003cli\u003eSupporta l’assorbimento di corrente dell’intero rack 3500 fino a un massimo di 2,5 A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplicazioni\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSistemi di protezione dei macchinari Bently Nevada della serie 3500\u003c\/li\u003e\n\u003cli\u003eSistemi industriali di monitoraggio delle condizioni dei macchinari\u003c\/li\u003e\n\u003cli\u003eConfigurazioni di distribuzione dell’alimentazione primaria e ridondante\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifiche tecniche\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParametro\u003c\/th\u003e\n\u003cth\u003eSpecifica\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduttore\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModello\u003c\/td\u003e\n\u003ctd\u003e129478-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTipo di modulo\u003c\/td\u003e\n\u003ctd\u003eModulo di ingresso dell’alimentazione CC ad alta tensione (PIM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerie del sistema\u003c\/td\u003e\n\u003ctd\u003e3500\/15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTensione di ingresso\u003c\/td\u003e\n\u003ctd\u003eDa 88 a 140 Vcc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssorbimento di corrente dell’intero rack\u003c\/td\u003e\n\u003ctd\u003eMassimo 2,5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtezione\u003c\/td\u003e\n\u003ctd\u003eIl fusibile si apre in caso di sovratensione; la sottotensione non danneggia il PIM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensioni (A x L x P)\u003c\/td\u003e\n\u003ctd\u003e120,7 mm x 25,4 mm x 114,3 mm (4,75 in x 1,0 in x 4,5 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeso\u003c\/td\u003e\n\u003ctd\u003e0,34 kg (0,75 lb.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperatura di esercizio\u003c\/td\u003e\n\u003ctd\u003eDa -30 degC a +65 degC (da -22 degF a +150 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperatura di stoccaggio\u003c\/td\u003e\n\u003ctd\u003eDa -40 degC a +85 degC (da -40 degF a +185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUmidità\u003c\/td\u003e\n\u003ctd\u003e95%, senza condensa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eLinee guida per l’installazione\u003c\/h3\u003e\n\u003cp\u003eIl modulo di ingresso dell’alimentazione è uno speciale modulo a mezza altezza situato direttamente dietro il modulo di alimentazione associato, sul lato sinistro del rack. Installare l’unità nell’apposito slot posteriore del rack. Verificare il corretto posizionamento del fusibile (codice del fusibile sostitutivo 01720025) prima di applicare l’alimentazione. Per il funzionamento non è richiesto alcun carico minimo del rack.\u003c\/p\u003e\n\u003ch3\u003eConformità e certificazioni\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNorme EMC:\u003c\/strong\u003e EN 61000-6-2, EN 55011\/CISPR 11, EN 61000-6-4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDirettive della Comunità Europea:\u003c\/strong\u003e Direttiva EMC 2004\/108\/CE\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNorme di sicurezza elettrica:\u003c\/strong\u003e EN 61010-1, Direttiva Bassa Tensione 2006\/95\/CE\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOmologazioni per aree pericolose (Opzione nordamericana 01):\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eCon barriere interne: Ex nC [ia] IIC: Classe I, Div 1; AEx nC [ia] IIC: Classe 1, Zona 2\/0, Gruppi A, B, C, D; T4 @ Ta = da -20 degC a +65 degC\u003c\/li\u003e\n\u003cli\u003eSenza barriere interne: Ex nC [L] IIC: Classe I, Div 2; AEx nC IIC: Classe 1, Div 2, Gruppi A, B, C, D; T4 @ Ta = da -20 degC a +65 degC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOmologazioni per aree pericolose (Opzione ATEX 02):\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eCon barriere interne: II 3\/(1) G, Ex nC[ia Ga] IIC T4 Gc, T4 @ Ta = da -20 degC a +65 degC\u003c\/li\u003e\n\u003cli\u003eSenza barriere interne: II 3\/(3) G, Ex nC[nL Gc] IIC T4 Gc, T4 @ Ta = da -20 degC a +65 degC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOmologazione brasiliana (Opzione 02):\u003c\/strong\u003e BR-Ex nC [nL] IIC T4, T4 @ Ta = da -20 degC a +65 degC\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666847592811,"sku":"129478-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-129478-01-high-dc-power-input-module-xx5cs5db2eg_b79155a2-f03c-4e2b-b4e1-7ef67da26e9a.jpg?v=1765448965"},{"product_id":"bently-nevada-3500-61-02-00-133827-02-temperature-monitor-rtd-tc-non-isolated-i-o-module","title":"Bently Nevada 3500\/61-02-00 133827-02 modulo I\/O del monitor di temperatura RTD\/TC non isolato","description":"\u003ch3\u003eDescrizione\u003c\/h3\u003e\n\u003cp\u003eIl \u003cstrong\u003e3500\/61-02-00\u003c\/strong\u003e è un modulo di monitoraggio della temperatura a sei canali progettato per il \u003cstrong\u003eBently Nevada 3500 Machinery Protection System\u003c\/strong\u003e. Il modulo accetta ingressi di temperatura sia RTD sia da termocoppia ed esegue funzioni continue di misurazione della temperatura e confronto degli allarmi per applicazioni con macchinari rotanti critici.\u003c\/p\u003e\n\u003cp\u003eIl \u003cstrong\u003e133827-02\u003c\/strong\u003e Il modulo I\/O RTD\/TC non isolato utilizza terminazioni esterne e supporta configurazioni miste degli ingressi RTD e TC. Gli utenti possono configurare i singoli canali tramite il software 3500 Rack Configuration per il funzionamento con RTD o termocoppia.\u003c\/p\u003e\n\u003cp\u003eIl \u003cstrong\u003e3500\/61\u003c\/strong\u003e la serie differisce dalla \u003cstrong\u003e3500\/60\u003c\/strong\u003e fornendo uscite del registratore per ciascun canale di monitoraggio. Le uscite del registratore supportano la trasmissione da 4 a 20 mA proporzionale all'intervallo del fondo scala configurato del monitor.\u003c\/p\u003e\n\u003cp\u003eIl modulo supporta fino a sei ingressi per trasduttori e fornisce setpoint di allarme programmabili di Avviso e Pericolo. Nei sistemi Triple Modular Redundant (TMR), i monitor della temperatura vengono installati adiacenti in gruppi di tre per supportare la logica di voto ridondante e la tolleranza ai guasti.\u003c\/p\u003e\n\u003cp\u003eIl modulo è adatto per sistemi di monitoraggio delle turbine, treni di compressori, impianti di processo, strutture per la generazione di energia e applicazioni di protezione dei macchinari industriali che richiedono la supervisione della temperatura e la gestione degli allarmi.\u003c\/p\u003e\n\u003ch3\u003eCaratteristiche\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMonitoraggio della temperatura a sei canali\u003c\/li\u003e\n\u003cli\u003eSupporta ingressi RTD e termocoppia\u003c\/li\u003e\n\u003cli\u003eSupporta la configurazione mista dei canali RTD e TC\u003c\/li\u003e\n\u003cli\u003eDesign I\/O non isolato con terminazioni esterne\u003c\/li\u003e\n\u003cli\u003eUscite del registratore per tutti e sei i canali\u003c\/li\u003e\n\u003cli\u003eSetpoint di allarme configurabili dall'utente\u003c\/li\u003e\n\u003cli\u003eModalità di misurazione RTD o TC configurabile tramite software\u003c\/li\u003e\n\u003cli\u003eCompatibile con il software 3500 Rack Configuration\u003c\/li\u003e\n\u003cli\u003eSupporta l'architettura dei sistemi TMR\u003c\/li\u003e\n\u003cli\u003eLED OK, TX\/RX e Bypass sul pannello frontale\u003c\/li\u003e\n\u003cli\u003eUscite del registratore da 4 a 20 mA\u003c\/li\u003e\n\u003cli\u003eConfigurazione del fondo scala dei canali tramite software\u003c\/li\u003e\n\u003cli\u003eNon è necessaria alcuna calibrazione\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplicazioni\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMonitoraggio della temperatura delle turbine a vapore\u003c\/li\u003e\n\u003cli\u003eSistemi di protezione delle turbine a gas\u003c\/li\u003e\n\u003cli\u003eSupervisione della temperatura dei compressori\u003c\/li\u003e\n\u003cli\u003eMonitoraggio dei macchinari rotanti industriali\u003c\/li\u003e\n\u003cli\u003eSistemi di arresto degli impianti di processo\u003c\/li\u003e\n\u003cli\u003eProtezione delle apparecchiature per la generazione di energia\u003c\/li\u003e\n\u003cli\u003eMonitoraggio dei processi petrolchimici\u003c\/li\u003e\n\u003cli\u003eMonitoraggio dei macchinari negli impianti LNG\u003c\/li\u003e\n\u003cli\u003eSistemi di allarme per apparecchiature critiche\u003c\/li\u003e\n\u003cli\u003eInstallazioni di protezione dei macchinari TMR\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInformazioni per l'ordinazione\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e3500\/61-02-00: kit completo di monitoraggio RTD\/TC con terminazioni esterne\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eSpecifica il kit completo contenente il modulo monitor principale 3500\/61 e la specifica scheda I\/O posteriore non isolata.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-02: Opzione del tipo di modulo I\/O\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eModulo I\/O non isolato RTD\/TC con terminazioni esterne (numero di parte della scheda posteriore: \u003cstrong\u003e133827-02\u003c\/strong\u003e).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-00: Opzione di approvazione dell'ente\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eNon sono necessarie approvazioni o certificazioni di enti per aree pericolose.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRicambi e accessori\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eNumero di parte \u003cstrong\u003e133827-02\u003c\/strong\u003e: Modulo I\/O non isolato RTD\/TC 3500\/61 sostitutivo con terminazioni esterne.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifiche tecniche\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCategoria\u003c\/th\u003e\n\u003cth\u003eSpecifiche\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduttore\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTipo di prodotto\u003c\/td\u003e\n\u003ctd\u003eModulo I\/O non isolato per monitoraggio della temperatura RTD\/TC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerie\u003c\/td\u003e\n\u003ctd\u003eSerie 3500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModello\u003c\/td\u003e\n\u003ctd\u003e3500\/61-02-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumero di parte di ricambio\u003c\/td\u003e\n\u003ctd\u003e133827-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCanali di ingresso\u003c\/td\u003e\n\u003ctd\u003eDa 1 a 6 segnali di trasduttori RTD o TC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpedenza d'ingresso\u003c\/td\u003e\n\u003ctd\u003e10 Mohm per ciascun ingresso del conduttore\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConsumo energetico\u003c\/td\u003e\n\u003ctd\u003e9 W nominali\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUscita del registratore\u003c\/td\u003e\n\u003ctd\u003eDa +4 a +20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConformità della tensione\u003c\/td\u003e\n\u003ctd\u003eDa 0 a +12 Vcc sul carico\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistenza di carico\u003c\/td\u003e\n\u003ctd\u003eDa 0 a 600 ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRisoluzione\u003c\/td\u003e\n\u003ctd\u003e0,3662 uA per bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSorgente di corrente RTD\u003c\/td\u003e\n\u003ctd\u003e925 +\/-15 uA a 25 °C per trasduttore\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntervallo di ritardo dell'allarme\u003c\/td\u003e\n\u003ctd\u003eAllerta: da 1 a 60 s, Pericolo: da 1 a 60 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperatura di esercizio\u003c\/td\u003e\n\u003ctd\u003e-30 °C a +65 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperatura di stoccaggio\u003c\/td\u003e\n\u003ctd\u003e-40 °C a +85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensioni del monitor\u003c\/td\u003e\n\u003ctd\u003e241,3 x 24,4 x 241,8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeso del monitor\u003c\/td\u003e\n\u003ctd\u003e0,91 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensioni del modulo I\/O\u003c\/td\u003e\n\u003ctd\u003e241,3 x 24,4 x 99,1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeso del modulo I\/O\u003c\/td\u003e\n\u003ctd\u003e0,45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRequisiti degli slot del rack\u003c\/td\u003e\n\u003ctd\u003e1 slot frontale a tutta altezza e 1 slot posteriore\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigine\u003c\/td\u003e\n\u003ctd\u003eStati Uniti\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSpecifiche dei RTD\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTipo di RTD\u003c\/td\u003e\n\u003ctd\u003eIntervallo di misura\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTD al platino da 100 ohm, alfa 0,00385\u003c\/td\u003e\n\u003ctd\u003e-200 °C a +850 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTD al platino da 100 ohm, alfa 0,00392\u003c\/td\u003e\n\u003ctd\u003e-200 °C a +700 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTD in nichel da 120 ohm\u003c\/td\u003e\n\u003ctd\u003e-80 °C a +260 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTD in rame da 10 ohm\u003c\/td\u003e\n\u003ctd\u003e-100 °C a +260 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSpecifiche delle termocoppie\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTipo di termocoppia\u003c\/td\u003e\n\u003ctd\u003eIntervallo di misura\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTipo E\u003c\/td\u003e\n\u003ctd\u003e-100 °C a +1000 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTipo J\u003c\/td\u003e\n\u003ctd\u003e-18 °C a +760 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTipo K\u003c\/td\u003e\n\u003ctd\u003e-18 °C a +1370 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTipo T\u003c\/td\u003e\n\u003ctd\u003e-160 °C a +400 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSpecifiche del condizionamento del segnale\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eParametro\u003c\/td\u003e\n\u003ctd\u003eSpecifiche\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRisoluzione RTD e TC\u003c\/td\u003e\n\u003ctd\u003e1 °C o 1 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRisoluzione del RTD in rame\u003c\/td\u003e\n\u003ctd\u003e1 °C o 1 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrecisione della compensazione della giunzione fredda\u003c\/td\u003e\n\u003ctd\u003e+\/-1 °C a 25 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrecisione dell'allarme\u003c\/td\u003e\n\u003ctd\u003eEntro lo 0,13% del valore desiderato\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrecisione della terminazione esterna non isolata\u003c\/td\u003e\n\u003ctd\u003e+\/-1 °C a 25 °C, rack standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrecisione del rack con montaggio a pannello\u003c\/td\u003e\n\u003ctd\u003e+\/-3 °C a 25 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eUscite e indicatori\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndicatore o uscita\u003c\/td\u003e\n\u003ctd\u003eFunzione\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLED OK\u003c\/td\u003e\n\u003ctd\u003eIndica il corretto funzionamento del monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLED TX\/RX\u003c\/td\u003e\n\u003ctd\u003eIndica la comunicazione con i moduli del rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLED bypass\u003c\/td\u003e\n\u003ctd\u003eIndica la modalità bypass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUscite del registratore\u003c\/td\u003e\n\u003ctd\u003eUscite individuali da 4 a 20 mA per canale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eNote di progettazione\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelezione RTD al platino\u003c\/strong\u003e: i RTD al platino con coefficiente alfa 0,00385 sono conformi agli standard industriali globali e sono consigliati per tutte le nuove installazioni di circuiti di temperatura.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eImmunità al cortocircuito del registratore\u003c\/strong\u003e: I circuiti interni garantiscono che il monitoraggio dei macchinari principali e la logica di allarme rimangano inalterati dai cortocircuiti sui circuiti esterni dei registratori.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSetpoint inferiori e superiori\u003c\/strong\u003e: Il motore di elaborazione interno fornisce limiti di allarme sia superiori sia inferiori per una protezione multidirezionale, ad esempio in condizioni criogeniche o di surriscaldamento.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRequisiti TMR\u003c\/strong\u003e: Quando configurati per la ridondanza modulare tripla, tre monitor di temperatura identici devono essere installati in slot consecutivi e adiacenti sul telaio anteriore.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eLinee guida operative\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCablaggio delle terminazioni esterne\u003c\/strong\u003e: Instradare tutti i cavi dei conduttori RTD o TC verso il blocco di terminazione esterno, assicurando connessioni pulite ed ermetiche ai gas per mantenere l'accuratezza della CJC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMessa a terra delle schermature\u003c\/strong\u003e: Collegare le schermature dei cavi esclusivamente al terminale designato per la messa a terra della schermatura sul modulo I\/O, per evitare anelli di massa e schermare dai disturbi elettromagnetici.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAbbinamento del sensore CJC\u003c\/strong\u003e: Assicurarsi che il sensore di compensazione della giunzione fredda sia fissato saldamente alla base dei terminali per garantire una compensazione accurata della temperatura ambiente durante le misurazioni con termocoppie.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRiduzione al minimo della resistenza dei cavi\u003c\/strong\u003e: Per i collegamenti RTD a 3 e 4 fili, mantenere identiche le lunghezze dei cavi per bilanciare la caduta di tensione sulla linea e garantire una compensazione accurata del ponte.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ tecniche e sugli approvvigionamenti\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eD: Qual è la differenza principale tra i moduli 3500\/60 e 3500\/61?\u003c\/strong\u003e R: Entrambi i moduli offrono un monitoraggio della temperatura e una logica di allarme identici, ma il 3500\/61 dispone di sei uscite indipendenti per registratori, da +4 a +20 mA, mentre il 3500\/60 ne è privo.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eD: Questa specifica opzione di modulo I\/O non isolato fornisce un isolamento tra i canali?\u003c\/strong\u003e R: No, questa è l'opzione 02, non isolata; se è necessario l'isolamento tra i canali per contrastare gravi guasti a terra o incroci di linee ad alta tensione, è necessario specificare la versione del modulo I\/O isolato.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eD: È necessaria la calibrazione sul campo per il modulo 3500\/61 al momento dell'installazione?\u003c\/strong\u003e R: Non è necessaria alcuna calibrazione sul campo, poiché gli intervalli a fondo scala e i tipi di sensore vengono configurati digitalmente tramite il software di configurazione del rack 3500.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666847691115,"sku":"3500\/61-02-00 133827-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-61-02-00-133827-02-rtd-tc-temperature-i-o-module-tul1fywpxs1_6cd7fe54-1ece-464e-8d43-bdb06cb565fb.jpg?v=1765448969"},{"product_id":"bently-nevada-3500-33-04-00-149992-04-low-current-16-channel-failsafe-relay-output-module","title":"Bently Nevada 3500\/33-04-00 149992-04 modulo di uscita relè fail-safe a bassa corrente e 16 canali","description":"\u003ch3\u003eDescrizione\u003c\/h3\u003e\n\u003cp\u003eIl \u003cstrong\u003eBently Nevada 3500\/33-04-00 149992-04\u003c\/strong\u003e è un \u003cstrong\u003emodulo di uscita relè fail-safe a 16 canali\u003c\/strong\u003e utilizzato come modulo principale o di ricambio nei \u003cstrong\u003esistemi di protezione dei macchinari 3500\u003c\/strong\u003e. Fornisce 16 uscite relè programmabili indipendentemente con logica di attivazione degli allarmi e supporta combinazioni logiche AND\/OR degli stati di avviso, pericolo e Non-OK, nonché delle variabili misurate da qualsiasi canale del monitor. Ogni uscita relè può eseguire logiche di votazione e integrarsi con il \u003cstrong\u003esoftware di configurazione rack 3500\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eQuesto modulo si interfaccia con sistemi \u003cstrong\u003ePLC, DCS, SIS e TSI\u003c\/strong\u003e, offrendo il funzionamento normalmente diseccitato (ND) e normalmente eccitato (NE), selezionabile in quattro gruppi di quattro canali. I LED sul pannello frontale indicano lo stato del modulo, l'attività di comunicazione e gli stati di allarme dei canali.\u003c\/p\u003e\n\u003cp\u003eSupporta applicazioni di commutazione a bassa corrente con contatti placcati in oro, adatti a configurazioni standard, fail-safe o per aree pericolose. Il modulo può essere installato a destra dell'interfaccia dati transitori (TDI) in un \u003cstrong\u003erack 3500\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eCaratteristiche\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e16 uscite relè con logica programmabile indipendente\u003c\/li\u003e\n\u003cli\u003eLogica di attivazione degli allarmi con condizioni AND\/OR\u003c\/li\u003e\n\u003cli\u003eFunzionamento selezionabile normalmente diseccitato (ND) o normalmente eccitato (NE)\u003c\/li\u003e\n\u003cli\u003eLED sul pannello frontale per lo stato OK, TX\/RX e gli allarmi dei canali\u003c\/li\u003e\n\u003cli\u003eRelè sigillati con resina epossidica e soppressori d'arco (250 Vrms)\u003c\/li\u003e\n\u003cli\u003eDurata dei relè fino a 10.000 cicli\u003c\/li\u003e\n\u003cli\u003eOpzione con contatti placcati in oro per basse correnti, per un carico minimo di 1 mA a 1 Vcc\u003c\/li\u003e\n\u003cli\u003eCompatibile con il software di configurazione rack 3500\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplicazioni\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMonitoraggio e protezione di macchinari industriali\u003c\/li\u003e\n\u003cli\u003eUscite di allarme per l'automazione dei processi\u003c\/li\u003e\n\u003cli\u003eInterfacciamento dei relè in aree pericolose\u003c\/li\u003e\n\u003cli\u003eIntegrazione con sistemi PLC, DCS, SIS e TSI\u003c\/li\u003e\n\u003cli\u003eCommutazione di segnali a bassa corrente nei pannelli di controllo\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInformazioni per l'ordine\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e3500\/33-04-00: Gruppo completo del modulo relè a 16 canali\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eSpecifica la combinazione preconfigurata composta dalla scheda del modulo principale anteriore e dalla scheda di uscita posteriore fail-safe per basse correnti.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-04: Opzione del tipo di modulo di uscita\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eModulo di uscita relè fail-safe a 16 canali per basse correnti, con contatti placcati in oro (modulo I\/O posteriore di ricambio: \u003cstrong\u003e149992-04\u003c\/strong\u003e).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-00: Opzione di approvazione per aree pericolose\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eNon sono richieste approvazioni o certificazioni da parte di enti per aree pericolose.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRicambi e accessori\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eCodice articolo \u003cstrong\u003e149992-04\u003c\/strong\u003e: Modulo di ricambio con uscite a relè Failsafe a bassa corrente e 16 canali.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifiche tecniche\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCategoria\u003c\/th\u003e\n\u003cth\u003eSpecifiche\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduttore\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigine\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeso\u003c\/td\u003e\n\u003ctd\u003eModulo principale: 0,7 kg (1,6 lb), modulo I\/O: 0,4 kg (1,0 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensioni\u003c\/td\u003e\n\u003ctd\u003eModulo principale: 241 x 24,4 x 242 mm (9,50 x 0,96 x 9,52 pollici), modulo I\/O: 241 x 24,4 x 99,1 mm (9,50 x 0,96 x 3,90 pollici)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpazio nel rack\u003c\/td\u003e\n\u003ctd\u003eModulo principale: 1 slot anteriore a tutta altezza, I\/O: 1 slot posteriore a tutta altezza\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConsumo energetico\u003c\/td\u003e\n\u003ctd\u003e5,8 watt tipici\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTipo di relè\u003c\/td\u003e\n\u003ctd\u003eSPDT (unipolare a due vie)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDurata dei contatti\u003c\/td\u003e\n\u003ctd\u003e10.000 cicli\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSoppressore dell'arco del relè\u003c\/td\u003e\n\u003ctd\u003e250 Vrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCorrente minima commutata\u003c\/td\u003e\n\u003ctd\u003eStandard: 100 mA a 5 Vcc, bassa corrente: 1 mA a 1 Vcc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCorrente massima commutata\u003c\/td\u003e\n\u003ctd\u003eCC: 5 A, CA: 5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePotenza massima commutata\u003c\/td\u003e\n\u003ctd\u003eCC: 70 W a 24 Vcc, CA: 1200 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTensione massima commutata\u003c\/td\u003e\n\u003ctd\u003eCC: 125 Vcc, CA: 250 Vca\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCaratteristiche ambientali\u003c\/td\u003e\n\u003ctd\u003eSigillato con resina epossidica\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndicatori LED\u003c\/td\u003e\n\u003ctd\u003eOK, TX\/RX, allarme CH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eCollegamenti\/Interfacce\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003ePin del connettore\u003c\/th\u003e\n\u003cth\u003eFunzione\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/D-Agent_1-_work-77-s-Upload-162096J1.pdf?v=1780026391\"\u003eConsultare il manuale del rack 3500\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eUscite relè, collegamenti di alimentazione e comunicazione\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eLinee guida per l'installazione\u003c\/h3\u003e\n\u003ch4\u003eMessa a terra e schermatura\u003c\/h4\u003e\n\u003cp\u003eAssicurarsi che il telaio del rack sia correttamente collegato alla terra della strumentazione dell'impianto prima di inserire i moduli. Le schermature del cablaggio di campo devono essere terminate sugli appositi terminali di schermatura del modulo I\/O per ridurre al minimo le interferenze elettromagnetiche e garantire l'integrità del segnale.\u003c\/p\u003e\n\u003ch4\u003ePrecauzioni per aree pericolose\u003c\/h4\u003e\n\u003cp\u003eNon scollegare il cablaggio di campo o i collegamenti del modulo mentre il circuito è sotto tensione, a meno che non sia stato verificato che l'area non sia pericolosa. La manipolazione sotto tensione in atmosfere esplosive può comportare rischi di innesco dovuti ad archi elettrici.\u003c\/p\u003e\n\u003ch4\u003ePosizionamento del modulo\u003c\/h4\u003e\n\u003cp\u003eAllineare il modulo principale con lo slot anteriore scelto, a destra del modulo TDI. Farlo scorrere saldamente nei connettori del backplane e serrare le viti del pannello. Installare il modulo I\/O corrispondente nello slot direttamente sul retro del gruppo rack.\u003c\/p\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eChe cosa indica l'opzione 04 nel codice articolo di questo modulo?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e Il codice 04 specifica che si tratta della variante Failsafe a bassa corrente e 16 canali, dotata di contatti placcati in oro.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQual è la corrente nominale minima per la versione con contatti placcati in oro?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eLa corrente minima commutabile nominale è 1 mA a 1 Vdc.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePosso combinare la configurazione per le modalità Normally Energized e Normally De-energized?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSì, i sedici canali sono suddivisi in quattro gruppi distinti di quattro canali, e ciascun gruppo può essere selezionato indipendentemente tramite un interruttore.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQual è la funzione del LED TX\/RX sul pannello frontale?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIl LED TX\/RX lampeggia per indicare la trasmissione e la ricezione attive dei dati di comunicazione tra questo modulo e gli altri moduli del rack.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuesto pacchetto hardware contiene una protezione integrata contro le scintille per i contatti?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSì, sui canali hardware è installato di serie un soppressore d'arco interno per relè, sigillato in resina epossidica, da 250 Vrms.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuesta unità può elaborare contemporaneamente singole variabili provenienti da più moduli monitor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSì, la logica Alarm Drive Logic può combinare ingressi Alert, Danger o Not-OK provenienti da qualsiasi canale del monitor o da qualsiasi combinazione di canali del monitor all'interno del rack.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuale strumento software è necessario per configurare i percorsi della logica di voto?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eLa logica del sistema viene progettata e caricata utilizzando il software 3500 Rack Configuration Software.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eChe cosa accade al funzionamento del relè se il modulo rileva un guasto interno?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIl design Failsafe garantisce che, in caso di guasto grave o perdita del controllo, i relè passino allo stato sicuro diseccitato o allo stato predefinito, a seconda del cablaggio.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eÈ sicuro superare i 5 mA quando si utilizza una tensione di alimentazione CA fino a 120 Vac?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, correnti superiori a 5 mA su questi relè dorati a bassa corrente deteriorano o danneggiano permanentemente la placcatura dei contatti.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuanti slot occupa l'intero gruppo principale e I\/O?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eOccupa uno slot a tutta altezza nella parte anteriore del rack e uno slot corrispondente a tutta altezza sul pannello posteriore.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePosso inserire questo modulo nello slot immediatamente adiacente all'alimentatore?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDeve essere installato in uno slot disponibile qualsiasi situato a destra del modulo Transient Data Interface.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eChe cosa indica una spia fissa sul LED OK?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUna spia fissa indica che l'hardware è acceso, ha superato gli autotest iniziali e funziona correttamente.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666848837995,"sku":"3500\/33-04-00 149992-04","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-33-04-00-149992-04-relay-i-o-module-fkulr4tcehu_c36c9898-9ec7-4d81-a6b1-b3299e531e38.jpg?v=1765448997"},{"product_id":"bently-nevada-3500-15-04-04-01-133300-01-legacy-low-voltage-dc-power-input-module","title":"Bently Nevada 3500\/15-04-04-01 133300-01 Legacy Low Voltage DC Power Input Module","description":"\u003cp style=\"color: #2d3748;\"\u003eThe \u003cstrong\u003eBently Nevada 3500\/15-04-04-01\u003c\/strong\u003e, operating in absolute conjunction with the \u003cstrong\u003e133300-01\u003c\/strong\u003e rear interface, is an industrial-grade half-height rack power conversion engine designed for the 3500 Series Machinery Protection System. This specific hardware combination forms a legacy low-voltage direct current input infrastructure, receiving raw plant supply vectors and executing high-isolation step-down regulation to feed the internal passive backplane rails with tightly monitored DC operating potentials.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 5px;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px;\"\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eTrue N+1 Redundant Topology:\u003c\/strong\u003e Supports continuous dual-supply allocation within a single rack configuration where the lower bay functions as the primary power source and the upper bay serves as an un-interrupted hot-standby unit.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eZero-Downtime Hot Swappability:\u003c\/strong\u003e Internal dynamic balancing circuits permit the physical removal or insertion of either power card while the machinery monitor rack remains fully energized, preventing false trips or protection blind spots.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eGalvanic Isolation Barrier:\u003c\/strong\u003e Designed with heavily separated circuitry paths between input terminals and backplane connections to absorb massive field-side voltage transients and ground-loop fluctuations.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eDedicated Power Input Module (PIM):\u003c\/strong\u003e Paired with the legacy 133300-01 rear module featuring robust terminal blocks and optimized input filter footprints dedicated to low-voltage battery banks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 5px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px;\"\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eCritical Turbomachinery Protection:\u003c\/strong\u003e Delivers stable operational rails for critical shaft vibration, thrust position, and speed monitoring modules across steam and gas turbine trains.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003ePlant Battery Bank Integration:\u003c\/strong\u003e Direct connection to central industrial 24V DC battery backup systems inside power generation and petrochemical processing facilities.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eHigh-Availability Control Cabinets:\u003c\/strong\u003e Deployment in remote machine enclosures demanding maximum system uptime via redundant instrumentation power.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 5px;\"\u003eOrdering Information\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"text-align: left; padding: 10px; font-weight: bold;\"\u003eOption Code\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 10px; font-weight: bold;\"\u003eEngineering Selection Detail\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\" colspan=\"2\"\u003e3500\/15-AA-BB-CC Base Configuration\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; padding-left: 20px;\"\u003eAA - 04\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eLegacy Low Voltage DC Power Supply (20 to 30 Vdc range)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; padding-left: 20px;\"\u003eBB - 04\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eLegacy Low Voltage DC Power Input Module (PIM)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; padding-left: 20px;\"\u003eCC - 01\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eAgency Approval Option: CSA-c-US (Class I, Division 2, Groups A, B, C, D)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\" colspan=\"2\"\u003eComponent Breakdown Part Numbers\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; padding-left: 20px;\"\u003e106M1081-01\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eLegacy Low Voltage DC Power Supply Main Card Assembly\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; padding-left: 20px;\"\u003e133300-01\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eLegacy Low Voltage DC Power Input Module (PIM) Rear Hardware\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 5px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"text-align: left; padding: 10px; font-weight: bold;\"\u003eTechnical Parameter\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 10px; font-weight: bold;\"\u003eVerified Engineering Value\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eInput Voltage Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e20 Vdc to 30 Vdc\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eMaximum Input Current\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e10.0 A continuous\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eTypical Power Consumption\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e230 Watts maximum under full chassis load configuration\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eOutput Regulated Rails\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e+5 Vdc, -5 Vdc, +15 Vdc, -15 Vdc distributed via passive backplane\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eDielectric Isolation Strength\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e500 Vdc terminal-to-chassis ground resistance rating\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eForm Factor Size\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eHalf-height card layout (Occupies specific left-side rack slots)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eOperating Temperature Limits\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e-20 Celsius to +65 Celsius\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eStorage Temperature Limits\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e-40 Celsius to +85 Celsius\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eRelative Humidity Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eUp to 95% relative humidity, non-condensing\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eFront Panel Status Monitoring\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eIntegrated green 'Supply OK' LED diode matrix\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eBently Nevada (A Baker Hughes Company)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eUnited States\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eMain Supply Card Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e0.77 kg (1.70 lb)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eRear Input PIM Card Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e0.31 kg (0.68 lb)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eTotal System Net Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e1.08 kg (2.38 lb)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e1.55 kg (Complete double-card boxed system)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e285 mm x 210 mm x 155 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 5px;\"\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"text-align: left; padding: 10px; font-weight: bold;\"\u003eTerminal Designation\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 10px; font-weight: bold;\"\u003eCircuit Interface Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eDC+\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003ePositive DC Input Line (Accepts +20 to +30 Vdc reference)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eDC-\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eNegative DC Return Line (Power circuit common return path)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eGND\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eSafety Earth Ground Connection (Direct metal frame path link)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 5px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 15px; margin-bottom: 20px; color: #9b2c2c;\"\u003e\n  \u003cstrong\u003eCRITICAL WARNING:\u003c\/strong\u003e Isolate the primary 24V DC upstream supply loop breaker before starting installation. Do not manipulate or wire live power lines directly to the 133300-01 rear compression block. Bridging live lines risks continuous arc flash generation, internal short circuits across the copper layers, and permanent failure of all monitoring cards on the common backplane.\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n  \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: inline-flex; align-items: center; justify-content: center; margin-right: 10px; flex-shrink: 0; font-weight: bold;\"\u003e1\u003c\/span\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eConnect a verified anti-static grounding wrist strap to the unpainted rack frame to discharge potential personal static build-up before opening module protection envelopes.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n  \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: inline-flex; align-items: center; justify-content: center; margin-right: 10px; flex-shrink: 0; font-weight: bold;\"\u003e2\u003c\/span\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003ePush the main half-height power card smoothly down its dedicated slot runners on the front left side of the 3500 chassis until it mates with the backplane pin assembly.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n  \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: inline-flex; align-items: center; justify-content: center; margin-right: 10px; flex-shrink: 0; font-weight: bold;\"\u003e3\u003c\/span\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eAlign the legacy 133300-01 power input card into the parallel rear bay position. Fully tighten the rear retaining screws to secure the unit against persistent mechanical vibrations.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n  \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: inline-flex; align-items: center; justify-content: center; margin-right: 10px; flex-shrink: 0; font-weight: bold;\"\u003e4\u003c\/span\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eStrip field feeder cables back by 7 millimeters, insert them firmly into the DC terminal clamp block matching the verified polarities, and torque the clamping screws down to specification.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666850673003,"sku":"3500\/15-04-04-01 133300-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-15-04-04-01-133300-01-low-voltage-dc-power-input-module-jkcdk13hega_bc249377-abc5-4e7b-890f-e8d2efa9342f.jpg?v=1765449036"},{"product_id":"bently-nevada-3300-30-six-channel-temperature-tc-input-monitor","title":"Bently Nevada 3300\/30 Six-Channel Temperature TC Input Monitor","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 3300\/30 Six-Channel Temperature Monitor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a six-channel temperature monitoring module designed for the legacy\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 3300 Monitoring System\u003c\/strong\u003e.\u003cbr\u003eThis version is specifically configured to accept\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eThermocouple (TC) inputs\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erather than RTD sensors.\u003c\/p\u003e\n\u003cp\u003eIt is commonly used to monitor critical temperature points in industrial machinery, including:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eBearing metal temperature\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eExhaust gas temperature\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStator winding temperature\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLube oil system temperature\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe monitor provides continuous protection through configurable alarm relays and standard recorder outputs, ensuring reliable thermal supervision in turbine, compressor, and generator applications.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ch3\u003e1. Inputs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eInput Capacity\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSupports up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esix (6) independent thermocouple inputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEach channel operates independently\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSupported Thermocouple Types\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eType\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eJ\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— Iron \/ Constantan\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eType\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eK\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— Chromel \/ Alumel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eType\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eE\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— Chromel \/ Constantan\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eType\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eT\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— Copper \/ Constantan\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCold Junction Compensation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eInternal compensation provided at the terminal block\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAutomatically corrects measurement drift caused by ambient temperature changes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnsures stable temperature accuracy across operating environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e2. Signal Conditioning\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eWithin\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e±2.2% of signal\u003c\/strong\u003e, plus thermocouple tolerance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReference temperature:\u003cbr\u003e\u003cstrong\u003e+25°C (+77°F)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOpen Thermocouple Detection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe monitor includes automatic fault detection when a thermocouple circuit opens.\u003c\/p\u003e\n\u003cp\u003eSelectable response modes:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUpscale drive\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— Forces reading to high value\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDownscale drive\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— Forces reading to low value\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis feature prevents machinery from operating without temperature protection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eScan Rate\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eAll six channels scanned approximately:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e0.5 seconds per cycle\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis scan speed is typical for machinery protection systems where temperature changes occur gradually compared to vibration signals.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e3. Outputs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRecorder Outputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUser-programmable analog outputs:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e+4 to +20 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e0 to -10 Vdc\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e+1 to +5 Vdc\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eBuffered Outputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAvailable for diagnostic and monitoring purposes:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eFront panel coaxial connectors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRear terminal block connections\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOne buffered output per channel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese outputs are typically connected to:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDCS systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePLC systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eData recorders\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCondition monitoring software\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e4. Alarms \u0026amp; Display\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e7-segment LCD temperature display\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShows real-time temperature value\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eChannel selection:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eUse the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ebutton\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCycles through Channel 1 to Channel 6\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAlarm Setpoints\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEach channel supports independent alarm configuration:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eAlert alarm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDanger alarm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBoth thresholds are fully adjustable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOK Indicator\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eOK LED\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econtinuously monitors system health, including:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMonitor electronics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThermocouple sensors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eField wiring integrity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eOrdering Information\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Format\u003c\/strong\u003e\u003c\/p\u003e\n\u003cpre class=\"overflow-visible! px-0!\"\u003e3300\/30-AXX-BXX-CXX-DXX-EXX\u003cbr\u003e\u003c\/pre\u003e\n\u003chr\u003e\n\u003ch3\u003eA — Full-Scale Range Option\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eCode\u003c\/th\u003e\n\u003cth class=\"\"\u003eTemperature Range\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003e0 to 100°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003e0 to 200°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e03\u003c\/td\u003e\n\u003ctd\u003e0 to 500°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e04\u003c\/td\u003e\n\u003ctd\u003e0 to 1000°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003e32 to 212°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e06\u003c\/td\u003e\n\u003ctd\u003e32 to 392°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e07\u003c\/td\u003e\n\u003ctd\u003e32 to 932°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e08\u003c\/td\u003e\n\u003ctd\u003e32 to 1832°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eB — Thermocouple Input Option\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eCode\u003c\/th\u003e\n\u003cth class=\"\"\u003eThermocouple Type\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eType J\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eType K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e03\u003c\/td\u003e\n\u003ctd\u003eType E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e04\u003c\/td\u003e\n\u003ctd\u003eType T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eC — Alarm Relay Option\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eCode\u003c\/th\u003e\n\u003cth class=\"\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eEpoxy-sealed relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eHermetically-sealed relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eD — Agency Approval Option\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eCode\u003c\/th\u003e\n\u003cth class=\"\"\u003eCertification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNot required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eCSA \/ NRTL \/ C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eATEX self-certification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eE — Safety Barrier Option\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eCode\u003c\/th\u003e\n\u003cth class=\"\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eExternal barriers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eInternal barriers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eEngineering \u0026amp; Installation Guide\u003c\/h2\u003e\n\u003ch3\u003eSpace Requirement\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300\/30 temperature monitor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDouble-width module\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eInstallation requirement:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOccupies\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003etwo (2) slots\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein the 3300 rack\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis is important when planning rack capacity in retrofit or expansion projects.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eThermocouple Lead Wire Requirement\u003c\/h3\u003e\n\u003cp\u003eAlways use the correct\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ethermocouple extension wire\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ethat matches the thermocouple type.\u003c\/p\u003e\n\u003cp\u003eExamples:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eType K → Type K extension wire\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eType J → Type J extension wire\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eUsing standard copper wire will introduce:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eJunction voltage errors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTemperature measurement drift\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCalibration inaccuracy\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis is one of the most common field installation mistakes.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eGrounding Practice\u003c\/h3\u003e\n\u003cp\u003eRecommended grounding method:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGround the thermocouple shield at the monitor rack only\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAvoid grounding at multiple points.\u003c\/p\u003e\n\u003cp\u003eImproper grounding can cause:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eGround loops\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSignal noise\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUnstable temperature readings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSpecial attention is required when using:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGrounded-tip thermocouples\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThese sensors are more sensitive to grounding configuration.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eCold Junction Environment Control\u003c\/h3\u003e\n\u003cp\u003eDo not install the monitor rack in locations with:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eRapid temperature changes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStrong airflow across terminal blocks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh thermal gradients\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese conditions can affect the accuracy of the internal cold junction compensation.\u003c\/p\u003e\n\u003cp\u003eTypical problematic locations:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eNear ventilation ducts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eClose to turbine exhaust paths\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOutdoor panels without thermal shielding\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666850935147,"sku":"3300\/30","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3300-30-position-monitor-module-aahygilvquw_7ed0cd2c-10d0-4b8c-b33c-9c8d65d61045.jpg?v=1765449041"},{"product_id":"bently-nevada-136703-01-3500-50-tachometer-monitor-i-o-module-with-internal-barriers-and-internal-terminations","title":"Bently Nevada 136703-01 3500\/50 Tachometer Monitor I\/O Module with Internal Barriers and Internal Terminations","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada \u003cstrong\u003e136703-01\u003c\/strong\u003e is a 3500\/50 Tachometer Monitor I\/O module designed for machinery protection and speed measurement applications in hazardous area environments. The \u003cstrong\u003e136703-01\u003c\/strong\u003e provides explosion protection as an intrinsically safe interface connected directly to the \u003cstrong\u003e3500 Machinery Protection System\u003c\/strong\u003e backplane and transducer systems.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIntegrates intrinsically safe internal barriers directly into the 3500 Machinery Protection System rack interface\u003c\/li\u003e\n\u003cli\u003eDesigned specifically for connection to 3500\/50 Tachometer Monitors with internal terminations\u003c\/li\u003e\n\u003cli\u003ePreserves system performance without degradation caused by external barriers\u003c\/li\u003e\n\u003cli\u003eProvides intrinsically safe earthing connection through the 3500 system backplane via dedicated IS Earthing Module\u003c\/li\u003e\n\u003cli\u003eAllows mixed installations of standard and internal barrier I\/O module types within the same 3500 rack\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMachinery protection and speed monitoring in hazardous process areas\u003c\/li\u003e\n\u003cli\u003eIndustrial rotating machinery including turbines, compressors, and large pumps\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003ePart Number\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e136703-01\u003c\/td\u003e\n\u003ctd\u003e3500\/50 I\/O Module with Internal Barriers and Internal Terminations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3500\/04-01\u003c\/td\u003e\n\u003ctd\u003eIS Earthing Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e136719-01\u003c\/td\u003e\n\u003ctd\u003eEarthing I\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e138257-01\u003c\/td\u003e\n\u003ctd\u003eEarthing Module Front Panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e136703-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500\/50 I\/O Module with Internal Barriers and Internal Terminations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Monitor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500\/50 Tachometer Monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRequired Firmware\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFirmware Version 1.05 Rev E or later\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRequired Software\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500 Rack Configuration software Revision 2.3 or later\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241.3 mm x 24.4 mm x 163.1 mm (9.50 in. x 0.96 in. x 6.42 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.46 kg (1.01 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Safety Voltage (Um)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOpen Circuit Voltage (Uo)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e27.45 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort Circuit Current (Io)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e113.24 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Capacitance (Co)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.086 uF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Inductance (Lo)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.77 mH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Power (Po)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e726.96 mW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmplitude Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3% @ 10 kHz, -15\/+10% @ 30 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-11 deg @ 10 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRequires a 3500\/04-01 IS Earthing Module installed in the same rack to provide the internal barrier IS earth connection.\u003c\/li\u003e\n\u003cli\u003eStandard 19-inch racks equipped with IS Earthing Modules are limited to 13 monitor positions.\u003c\/li\u003e\n\u003cli\u003eInternal barrier I\/O modules increase overall rack depth by approximately 50 mm (2 in) to provide required 50 mm (2 in) separation between hazardous and safe area field wiring.\u003c\/li\u003e\n\u003cli\u003eRoute hazardous area field wiring above the 3500 rack and safe area field wiring below the 3500 rack.\u003c\/li\u003e\n\u003cli\u003eGroup internal barrier I\/O modules in adjacent rack positions to simplify field wiring separation.\u003c\/li\u003e\n\u003cli\u003eNot compatible with Triple Modular Redundant (TMR) rack configurations or magnetic pick-up transducers.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification \/ Standard\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFCC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComplies with part 15 of FCC Rules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC Directive 2014\/30\/EU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN 61000-6-2, EN 61000-6-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLV Directive 2014\/35\/EU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN 61010-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRoHS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDirective 2011\/65\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMarine Approvals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABS - Marine and Offshore Applications; DNV GL Rules for Classification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCSA\/NRTL\/C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass I, Zone 2: AEx\/Ex nA nC ic IIC T4 Gc; Class I, Zone 2: AEx\/Ex ec nC ic IIC T4 Gc; Class I, Division 2, Groups A, B, C, D; T4 @ Ta= -20 degC to +65 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eATEX\/IECEx\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eII 3 G; Ex nA nC ic IIC T4 Gc; Ex ec nC ic IIC T4\/T5 Gc; T4 @ Ta= -20 degC to +65 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666851230059,"sku":"136703-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-136703-01-discrete-internal-barrier-i-o-module-blxxhvv0ljr_a844dcf0-a759-45c9-9f91-b7ee58da560f.jpg?v=1765449047"},{"product_id":"bently-nevada-135813-01-3500-93-display-interface-i-o-module","title":"Bently Nevada 135813-01 3500\/93 Display Interface I\/O Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada \u003cstrong\u003e135813-01\u003c\/strong\u003e is a Display Interface I\/O Module designed for local or remote visual indication of all 3500 Machinery Protection System information residing in the rack. The \u003cstrong\u003e135813-01\u003c\/strong\u003e interacts with the 3500 backplane network to collect current values, System Event Lists, Alarm Event Lists, and status data across all channel, monitor, relay, Keyphasor, or tachometer modules. The module provides hardware interface output connectivity for communication with the 3500\/93 Display Unit via an RS422 physical layer supporting Bently Nevada proprietary protocol and Modbus protocol.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOccupies 1 full-height rear slot in the 3500 rack\u003c\/li\u003e\n\u003cli\u003eFeatures a dedicated Display Communications Port for RS422 connection to the 3500\/93 Display Unit\u003c\/li\u003e\n\u003cli\u003eCollects machinery protection data and event status via a high-speed internal backplane network\u003c\/li\u003e\n\u003cli\u003eEnables rear cable routing option for connecting the display unit to the 3500 Machinery Protection System\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLocal or remote display interface connection for 3500 Machinery Protection Systems\u003c\/li\u003e\n\u003cli\u003eIndustrial rotating machinery monitoring and visual indication\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003ePart Number\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e135813-01\u003c\/td\u003e\n\u003ctd\u003e3500\/93 Display Interface I\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e135799-01\u003c\/td\u003e\n\u003ctd\u003e3500\/93 Display Interface Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e135799-02\u003c\/td\u003e\n\u003ctd\u003e3500\/93 Display Interface Module (use with A05 thru A08 options)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e135785-01\u003c\/td\u003e\n\u003ctd\u003e3500\/93 Display Unit, non back-lighted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e135785-02\u003c\/td\u003e\n\u003ctd\u003e3500\/93 Display Unit, back-lighted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e135813-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDisplay Interface I\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241.3 mm x 24.4 mm x 99.1 mm (9.50 in x 0.96 in x 3.90 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.38 kg (0.84 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRack Space Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 full-height rear slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 degC to +65 degC (-22 degF to +150 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC (-40 degF to +185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95%, noncondensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Hardware\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS422 Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGE Bently Nevada proprietary protocol, Modbus protocol (based on AEG PI-MBUS-300 Rev. E Reference Manual)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannel Update Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 second, typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eConnector \/ Port\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Communications Port\u003c\/td\u003e\n\u003ctd\u003eRS422 interface for connecting to the 3500\/93 Display Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstalls in 1 full-height rear slot of the 3500 Machinery Protection System rack.\u003c\/li\u003e\n\u003cli\u003eServes as the rear wiring interface point connecting to the front-mounted Display Interface Module (DIM) via the rack backplane.\u003c\/li\u003e\n\u003cli\u003eAllows display connection routing from the rear of the rack when the display is not face-mounted.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard \/ Directive\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC Standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN 61000-6-2 Immunity for Industrial Environments, EN 55011\/CISPR 11 ISM Equipment, EN 61000-6-4 Emissions for Industrial Environments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEuropean Community Directives\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEMC Directive 2004\/108\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical Safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN 61010-1, 2006\/95\/EC Low Voltage Directive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCSA\/NRTL\/C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOption (01): AEx nA IIC: Class I, Zone 2, Div 2 Groups A, B, C, D; T4 @ Ta = -30 degC to +65 degC (-22 degF to +150 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eATEX\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOption (02): II 3\/ (1) G Ex nC[nL Gc] IIC T4 Gc; T4 @ Ta = -20 degC to +65 degC (-4 degF to +150 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrazil\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOption (02): BR-Ex nC [nL] IIC T4; T4 @ Ta = -20 degC to +65 degC (-4 degF to +150 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSouth Africa\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOption (02): Ex nCAL [ia] IIC T4, Ex nCAL [L] IIC T4; T4 @ Ta = -20 degC to +65 degC (-4 degF to +150 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666851295595,"sku":"135813-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-135813-01-display-interface-i-o-module-q2bfa01gfs1_bc5bfd62-9a70-40b6-bcae-429336ab90ea.jpg?v=1765449050"},{"product_id":"bently-nevada-106m2686-01-universal-ac-power-input-module-for-3500-15","title":"Bently Nevada 106M2686-01 Universal AC Power Input Module for 3500\/15","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 106M2686-01\u003c\/strong\u003e is a power input module associated with the \u003cstrong\u003e3500\/15 Power Supply\u003c\/strong\u003e in the Bently Nevada 3500 machinery protection system.\u003c\/p\u003e\n\u003cp\u003eThe module accepts an AC input range of \u003cstrong\u003e85-250 VAC\u003c\/strong\u003e with a specified input frequency of \u003cstrong\u003e47-63 Hz\u003c\/strong\u003e. The listed maximum input current is \u003cstrong\u003e2.8 A\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe 106M2686-01 serves as the power-input interface for the associated 3500\/15 power supply assembly. Its function is to provide the required incoming AC power connection for the rack power supply architecture.\u003c\/p\u003e\n\u003cp\u003eBecause the part number is an individual 3500 system component, replacement work should verify both the exact module number and the installed 3500\/15 power supply configuration before installation.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003ePower input module for the Bently Nevada 3500\/15 Power Supply\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAC input range of 85-250 VAC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInput frequency range of 47-63 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaximum input current of 2.8 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDesigned for use within the Bently Nevada 3500 system power architecture\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSuitable for maintenance and replacement of an existing matching power input module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003ePower input interface for Bently Nevada 3500\/15 power supplies\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMachinery protection system rack maintenance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReplacement of matching 3500 power-supply input hardware\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower-system servicing in installed Bently Nevada 3500 racks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e106M2686-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eUniversal AC Power Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssociated System\u003c\/td\u003e\n\u003ctd\u003e3500 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssociated Module\u003c\/td\u003e\n\u003ctd\u003e3500\/15 Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e85-250 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Input Current\u003c\/td\u003e\n\u003ctd\u003e2.8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e47-63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.70 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cp\u003eVerify the exact part number \u003cstrong\u003e106M2686-01\u003c\/strong\u003e before removing the installed module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfirm that the existing rack uses the corresponding 3500\/15 power supply configuration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIsolate incoming power before servicing the rack power assembly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInspect the replacement module and mating connections before installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePreserve existing wiring identification before disconnecting the original module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReinstall connections according to the existing system documentation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCheck the power input and rack power-supply condition before returning the system to service.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfirm normal system operation after replacement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eReplacement Recommendations\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada 106M2686-01 should be replaced only with a unit matching the installed 3500\/15 power supply arrangement.\u003c\/p\u003e\n\u003cp\u003eRecord the existing input wiring and rack configuration before removal. This reduces the risk of wiring errors during maintenance.\u003c\/p\u003e\n\u003cp\u003eDo not assume compatibility from the 3500 Series name alone. Verify the exact power supply assembly and part number before procurement.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666851688811,"sku":"106M2686-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-106m2686-01-relay-module-zoxy4pjs3so_5b822b51-dfae-40ed-b61c-de1813a3ddc8.jpg?v=1765449067"},{"product_id":"bently-nevada-136188-02-3500-92-ethernet-rs485-modbus-i-o-module","title":"Bently Nevada 136188-02 3500\/92 Ethernet\/RS485 Modbus I\/O Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 136188-02\u003c\/strong\u003e is an Ethernet\/RS485 Modbus I\/O Module designed for use with the \u003cstrong\u003e3500\/92 Communication Gateway\u003c\/strong\u003e in the 3500 Series machinery protection system. Installed in the rear slot of the 3500 rack, it provides both Ethernet TCP\/IP and serial RS485 communication interfaces to transmit rack-monitored values, module statuses, and current alarm statuses to process control and automation systems. This module supports Modbus\/TCP, serial Modbus RTU, and proprietary Bently Nevada protocols, enabling integration with DCS\/PLC platforms as well as 3500 Rack Configuration and Data Acquisition Software. This spare module package includes the Firmware Upgrade Kit (126M4118-01).\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProvides Ethernet TCP\/IP and serial RS485 communication interfaces for the 3500\/92 Communication Gateway.\u003c\/li\u003e\n\u003cli\u003eSupports Modbus\/TCP, Modbus RTU, and Bently Nevada host protocol communication.\u003c\/li\u003e\n\u003cli\u003eEnables data transmission of measured values, time stamps, module statuses, and alarm statuses across process automation systems.\u003c\/li\u003e\n\u003cli\u003eFeatures an RJ-45 connection for 10BASE-T Ethernet networks.\u003c\/li\u003e\n\u003cli\u003eIncludes the 126M4118-01 Firmware Upgrade Kit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMachinery protection system integration with Distributed Control Systems (DCS) and Programmable Logic Controllers (PLC).\u003c\/li\u003e\n\u003cli\u003eTurbomachinery and rotating equipment monitoring in oil and gas, power generation, and chemical processing facilities.\u003c\/li\u003e\n\u003cli\u003eRemote rack configuration and data collection via 3500 Configuration and Data Acquisition Software.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e3500\/92-AA-BB-CC\u003c\/td\u003e\n\u003ctd\u003e3500\/92 Communication Gateway\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA: I\/O Module Type - 04\u003c\/td\u003e\n\u003ctd\u003eEthernet\/RS485 Modbus I\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpares: 136188-02\u003c\/td\u003e\n\u003ctd\u003eEthernet\/RS485 Modbus I\/O Module (Includes Firmware Upgrade Kit 126M4118-01)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessory: 126M4118-01\u003c\/td\u003e\n\u003ctd\u003eFirmware Upgrade Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e136188-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eEthernet\/RS485 Modbus I\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003eBently Nevada 3500\/92 Communication Gateway\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Interface\u003c\/td\u003e\n\u003ctd\u003e10Mbps, conforms to IEEE802.3 Ethernet TCP\/IP frame and Modbus\/TCP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Connection\u003c\/td\u003e\n\u003ctd\u003eRJ-45 (telephone jack style) for 10BASE-T Ethernet cabling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Interface\u003c\/td\u003e\n\u003ctd\u003eRS485 Modbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-30 degC to +65 degC (-22 degF to +149 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC (-40 degF to +185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Module Dimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e241 mm x 24.4 mm x 99.1 mm (9.50 in x 0.96 in x 3.90 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Module Weight\u003c\/td\u003e\n\u003ctd\u003e0.44 kg (0.96 lb.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Space Requirements\u003c\/td\u003e\n\u003ctd\u003e1 full-height rear slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlot Placement:\u003c\/strong\u003e Install the Ethernet\/RS485 Modbus I\/O Module into a full-height rear slot directly behind the 3500\/92 Communication Gateway main module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEthernet Cabling:\u003c\/strong\u003e Use standard 10BASE-T shielded Category 5 cable with RJ-45 connectors for Ethernet communication.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSerial Cabling:\u003c\/strong\u003e Follow proper RS485 polarity and shield grounding guidelines. Total RS485 cable runs can be up to 4000 feet (1220 meters).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFirmware Upgrade:\u003c\/strong\u003e Ensure proper installation of the included Firmware Upgrade Kit (126M4118-01) if upgrading older 3500\/92 Communication Gateway modules to ensure hardware compatibility.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC:\u003c\/strong\u003e European Community Directive 2014\/30\/EU; EN 61000-6-2, EN 61000-6-4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Safety:\u003c\/strong\u003e European Community Directive 2014\/35\/EU; EN 61010-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e European Community Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFCC:\u003c\/strong\u003e Complies with part 15 of the FCC Rules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area Approvals:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003ecNRTLus: Class I, Zone 2: AEx\/Ex nA nC ic IIC T4 Gc; Class I, Zone 2: AEx\/Ex ec nC ic IIC T4 Gc; Class I, Division 2, Groups A, B, C, and D; T4 @ Ta = -20 degC to +65 degC (-4 degF to +149 degF)\u003c\/li\u003e\n\u003cli\u003eATEX\/IECEx: Ex II 3 G, Ex nA nC ic IIC T4 Gc, Ex ec nC ic IIC T4 Gc, T4 @ Ta = -20 degC to +65 degC (-4 degF to +149 degF)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaritime:\u003c\/strong\u003e DNV GL rules for classification; ABS Rules for Condition of Classification, Part 1\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666851787115,"sku":"136188-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-136188-02-ethernet-rs232-modbus-i-o-module-ud51yhs3c54_e91e93c7-3aee-4677-8851-cc029494f61a.jpg?v=1765449070"},{"product_id":"bently-nevada-3500-92-03-01-00-136188-01-ethernet-rs232-modbus-i-o-module","title":"Bently Nevada 3500\/92-03-01-00 136188-01 Ethernet\/RS232 Modbus I\/O Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 3500\/92-03-01-00\u003c\/strong\u003e is a \u003cstrong\u003eCommunication Gateway Module\u003c\/strong\u003e designed for the \u003cstrong\u003e3500 Series Machinery Protection System\u003c\/strong\u003e. Its primary purpose is to provide continuous, high-speed communication capability for all rack-monitored values and statuses, enabling seamless integration with distributed control systems (DCS), programmable logic controllers (PLC), human-machine interfaces (HMI), and other plant automation systems.\u003c\/p\u003e\n\u003cp\u003eThe module features comprehensive communication interfaces, utilizing both Ethernet TCP\/IP and serial channels (RS232) via the \u003cstrong\u003e136188-01 I\/O module\u003c\/strong\u003e. It handles internal data collection by pulling current measured values, time stamps, module statuses, and alarm statuses from other monitor modules within the rack via a high-speed internal network. Additionally, the \u003cstrong\u003e3500\/92\u003c\/strong\u003e supports direct Ethernet communication with proprietary \u003cstrong\u003e3500 Rack Configuration Software\u003c\/strong\u003e and \u003cstrong\u003eData Acquisition Software\u003c\/strong\u003e. This specific variant features a Configurable Modbus Register Utility to map system data efficiently into host automation networks.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eContinuous collection of rack data, including current measured values with time stamps, module statuses, and alarm statuses.\u003c\/li\u003e\n\u003cli\u003eSimultaneous communication capability over Ethernet TCP\/IP and serial links.\u003c\/li\u003e\n\u003cli\u003eConfigurable Modbus Register Utility to customize register mapping for host systems.\u003c\/li\u003e\n\u003cli\u003eHigh-speed internal network collection rate that updates all rack modules in less than 1 second.\u003c\/li\u003e\n\u003cli\u003eFront panel LED indicators for immediate monitoring of module operational status (OK) and communication activity (TX\/RX).\u003c\/li\u003e\n\u003cli\u003eBackward compatibility with software features of the original 3500\/90 module.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSteam and gas turbine vibration and status monitoring integration.\u003c\/li\u003e\n\u003cli\u003eCompressor and pump protection data transmission to plant DCS.\u003c\/li\u003e\n\u003cli\u003eIndustrial machinery condition monitoring and predictive maintenance networks.\u003c\/li\u003e\n\u003cli\u003ePower generation and petrochemical plant automation synchronization.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e3500\/92: Communication Gateway\u003c\/li\u003e\n\u003cli\u003e03: Ethernet\/RS232 Modbus I\/O Module\u003c\/li\u003e\n\u003cli\u003e01: Low Memory\u003c\/li\u003e\n\u003cli\u003e00: None Agency Approval Option\u003c\/li\u003e\n\u003cli\u003e136188-01: Ethernet\/RS232 Modbus I\/O Module Spare (Includes Firmware Upgrade Kit 126M4118-01)\u003c\/li\u003e\n\u003cli\u003e126M4118-01: Firmware Upgrade Kit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003e5.0 Watts typical with Modbus RS232\/RS422 I\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003e\u003cstrong\u003eData Types\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eCurrent measured values with time stamp, module statuses, current alarm statuses\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003e\u003cstrong\u003eUpdate Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003eLess than 1 second for all modules in the 3500 rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003e\u003cstrong\u003eOK LED Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003eIndicates when the 3500\/92 is operating properly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003e\u003cstrong\u003eTX\/RX LED Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003eIndicates when the 3500\/92 is communicating with other modules in the 3500 rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003e\u003cstrong\u003eBNC Host Protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003eEthernet TCP\/IP connection to 3500 Configuration and Data Acquisition Software\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003e\u003cstrong\u003eModbus Protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003eBased on AEG Modicon PI-MBUS-300 Reference Manual, Remote Terminal Unit (RTU) transmission mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003e\u003cstrong\u003eEthernet Link Speed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003e10 Mbps, conforms to IEEE 802.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"12\"\u003e\u003cstrong\u003eEthernet Protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"12\"\u003eEthernet TCP\/IP frame and Modbus\/TCP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"13\"\u003e\u003cstrong\u003eEthernet Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"13\"\u003eRJ-45 for 10BASE-T Ethernet cabling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"14\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"14\"\u003e-30 degC to +65 degC (-22 degF to +149 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"15\"\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"15\"\u003e-40 degC to +85 degC (-40 degF to +185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"16\"\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"16\"\u003e95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"17\"\u003e\u003cstrong\u003eMain Board Dimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"17\"\u003e241 mm x 24.4 mm x 242 mm (9.50 in x 0.96 in x 9.52 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"18\"\u003e\u003cstrong\u003eI\/O Module Dimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"18\"\u003e241 mm x 24.4 mm x 99.1 mm (9.50 in x 0.96 in x 3.90 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"19\"\u003e\u003cstrong\u003eMain Board Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"19\"\u003e0.82 kg (1.8 lb.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"20\"\u003e\u003cstrong\u003eI\/O Module Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"20\"\u003e0.44 kg (0.96 lb.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"21\"\u003e\u003cstrong\u003eTotal Assembly Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"21\"\u003e1.26 kg (2.76 lb.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eConnector Pin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eRJ-45 Jack\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e10BASE-T Ethernet TCP\/IP and Modbus\/TCP Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eSerial Port (RS232)\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eModicon Modbus RTU Serial Communication Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFirmware Verification:\u003c\/strong\u003e Ensure that older Communication Gateway main modules are upgraded using Firmware Upgrade Kit 126M4118-01 before installing the new 136188-01 I\/O module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack Insertion:\u003c\/strong\u003e Insert the main board into the designated communication slot of the 3500 rack, ensuring full seating and secure fastening of the chassis screws.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Module Alignment:\u003c\/strong\u003e Install the 136188-01 I\/O module directly behind the main module from the rear of the 3500 rack.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCabling Constraints:\u003c\/strong\u003e Use standard 10BASE-T Ethernet cabling with RJ-45 connectors for network setups, limiting cable runs according to IEEE 802.3 metrics.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Control:\u003c\/strong\u003e Ensure operating ambient conditions do not exceed 65 degC and that ventilation paths on the 3500 chassis remain unobstructed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ecNRTLus\u003c\/li\u003e\n\u003cli\u003eATEX\u003c\/li\u003e\n\u003cli\u003eIECEx\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the function of the 3500\/92 module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt acts as a communication gateway, exporting data from a 3500 machinery protection rack to external automation systems like PLCs and DCS.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhich interfaces are provided on the 136188-01 I\/O module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt provides an RJ-45 Ethernet connection and an RS232 serial interface.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat protocols can run over the Ethernet connection?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt supports Modbus\/TCP protocol as well as the proprietary Bently Nevada host protocol for software applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does this module differ from the older 3500\/90 module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt removes the fixed primary value Modbus registers and replaces them with a flexible Configurable Modbus Register Utility.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow long does it take for the module to refresh data from the rack?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe data collection rate varies by configuration but is guaranteed not to exceed 1 second for all modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the typical power consumption of this specific I\/O setup?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe system typically consumes 5.0 Watts when equipped with the Modbus RS232 I\/O module configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I connect my 3500 Configuration Software through this gateway?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, it allows Ethernet communications with the 3500 Rack Configuration and Data Acquisition Software packages.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat should I check if the TX\/RX LED is dark?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eVerify that the module is correctly seated and that the internal rack communication bus is active and functioning.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs a firmware upgrade mandatory when swapping in a new 136188-01 interface?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eOlder main gateway modules require a firmware upgrade using kit 126M4118-01 to properly recognize the new I\/O hardware.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the environmental storage limitations for this hardware?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module must be stored within an environment ambient temperature range of -40 degC to +85 degC.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666852540779,"sku":"3500\/92-03-01-00 136188-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-92-03-01-00-136188-01-ethernet-rs232-modbusi-o-module-p13m3rotikn_8ccc5100-a46c-4dba-8a08-f4cf661d45b3.jpg?v=1765449087"},{"product_id":"bently-nevada-3500-04-01-136719-01-earthing-i-o-module","title":"Bently Nevada 3500\/04-01 136719-01 Earthing I\/O Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 136719-01\u003c\/strong\u003e (part of the \u003cstrong\u003e3500\/04-01\u003c\/strong\u003e assembly) is an Earthing I\/O Module designed for intrinsically safe (IS) ground reference management within the 3500 Machinery Protection System. Installed directly into the rear of the 3500 system rack, the \u003cstrong\u003e136719-01\u003c\/strong\u003e provides the essential intrinsically safe earth connection through the 3500 system backplane to interface with internal barrier monitor I\/O modules. This configuration enables safe, direct interconnection with approved field transducers—such as 3300 XL Proximitor sensors, Velomitor sensors, thermocouples, and RTDs—operating in hazardous environments without requiring external barriers or compromising system performance.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProvides the intrinsically safe ground connection for internal barrier I\/O modules via the 3500 system backplane.\u003c\/li\u003e\n\u003cli\u003eInstalls in a dedicated monitor position within the standard 3500 Machinery Protection System rack.\u003c\/li\u003e\n\u003cli\u003eFully integrated backplane routing eliminates the need for external zener or galvanic isolation barrier units.\u003c\/li\u003e\n\u003cli\u003eSupports combined rack layouts hosting both internal barrier modules and standard I\/O modules.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIntrinsically safe field wiring grounding for 3500 Machinery Protection Systems in hazardous industrial areas.\u003c\/li\u003e\n\u003cli\u003eTurbomachinery vibration, speed, position, and temperature monitoring systems requiring IS loop protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003ePart Number \/ Option Code\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/04-AA-BB\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500\/04 Internal Barrier System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA: I\/O Module Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e01\u003c\/strong\u003e Earthing I\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB: Agency Approval\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e None\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e01\u003c\/strong\u003e North American Hazloc\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e Multi (CSA, ATEX, IECEx)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e136719-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEarthing I\/O Module (Spare Part)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e138257-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEarthing Module Front Panel (Spare Part)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification Category\u003c\/th\u003e\n\u003cth\u003eParameter \/ Value\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEarthing I\/O Module (3500\/04 IS Earthing Module)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241 mm x 24.4 mm x 103.1 mm (9.50 in. x 0.96 in. x 4.06 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.201 kg (0.443 lb.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack Slot Allocation:\u003c\/strong\u003e The \u003cstrong\u003e136719-01\u003c\/strong\u003e IS Earthing Module requires a dedicated monitor position in the rack, which limits a standard 19-inch rack to 13 monitor positions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePositioning:\u003c\/strong\u003e Locate the IS Earthing Module in a rack position that allows easy access for routine online maintenance. When positioned between internal barrier I\/O modules, allow a minimum of two rack positions to facilitate online access.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRequirement:\u003c\/strong\u003e Any 3500 rack containing internal barrier I\/O modules must be equipped with a 3500\/04-01 IS Earthing Module to provide the backplane IS earth path.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Separation:\u003c\/strong\u003e Route hazardous area field wiring above the 3500 rack and safe area wiring below to maintain a minimum physical separation of 50 mm (2 in).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard \/ Approval Type\u003c\/th\u003e\n\u003cth\u003eCertificate \/ Standard Level\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFCC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComplies with Part 15 of FCC Rules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC Directive\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEuropean Community Directive 2014\/30\/EU; EN 61000-6-2, EN 61000-6-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical Safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEuropean Community Directive 2014\/35\/EU; EN 61010-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMarine Classification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDNV GL rules for classification; ABS Rules Part 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ecNRTLus\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass I, Zone 2: AEx\/Ex nA nC ic IIC T4 Gc; Class I, Zone 2: AEx\/Ex ec nC ic IIC T4 Gc; Class I, Division 2, Groups A, B, C, D; T4 @ Ta = -20 degC to +65 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eATEX \/ IECEx\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eII 3 G; Ex nA nC ic IIC T4 Gc; Ex ec nC ic IIC T4 Gc; T4 @ Ta = -20 degC to +65 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666853032299,"sku":"136719-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-136719-01-earthing-i-o-module-xnvjpe1wthl_06e1e8b2-6df2-4bbe-ac6d-fe1d51d1ff8d.jpg?v=1765449103"},{"product_id":"bently-nevada-126599-01-3500-44m-aero-gt-i-o-module","title":"Bently Nevada 126599-01 3500\/44M Aero GT I\/O Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e126599-01\u003c\/strong\u003e is an Aero GT I\/O module with internal terminations manufactured by \u003cstrong\u003eBently Nevada\u003c\/strong\u003e for the 3500\/44M Aeroderivitive GT Vibration Monitor. Installed in a full-height rear slot of a 3500 rack, the \u003cstrong\u003e126599-01\u003c\/strong\u003e accepts input signals from interface modules (part numbers 86517 and 86497), Velomitors, and accelerometers to monitor aeroderivative gas turbine machinery. The module operates in conjunction with the 3500\/44M main monitor module, accepting inputs from two separate Keyphasor signals and routing signals for 1X vibration tracking, band-pass vibration, and signal integration. It includes internal termination connections for transducer inputs, recorder outputs, and inhibit controls.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFull-height rear I\/O module with internal termination wiring headers\u003c\/li\u003e\n\u003cli\u003eInterfaces with interface modules (PN 86517 and 86497), Velomitors, and accelerometers\u003c\/li\u003e\n\u003cli\u003eRoutes input signals for aeroderivative gas turbine monitoring applications\u003c\/li\u003e\n\u003cli\u003eSupports dual Keyphasor signal inputs across channel pairs\u003c\/li\u003e\n\u003cli\u003eConnects directly to the 3500\/44M Aeroderivitive GT Vibration Monitor main board via the rack backplane\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAeroderivative gas turbine vibration monitoring\u003c\/li\u003e\n\u003cli\u003eMachinery protection and automated alarm trip systems\u003c\/li\u003e\n\u003cli\u003eIndustrial gas turbine condition monitoring loops\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003ePart Number \/ Option\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/44-AA-BB\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAeroderivative Monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA: I\/O Module Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eAero GT I\/O Module with Internal Terminations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eAero GT I\/O Module with External Terminations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003eProx\/Velom I\/O Module with Internal Terminations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e06\u003c\/td\u003e\n\u003ctd\u003eProx\/Velom I\/O Module with External Terminations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e07\u003c\/td\u003e\n\u003ctd\u003eMultimode Prox\/Velom I\/O Module with Internal Terminations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e08\u003c\/td\u003e\n\u003ctd\u003eMultimode Prox\/Velom I\/O Module with External Terminations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB: Hazardous Area Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003ecNRTLus (Class 1, Division 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eATEX\/IECEx\/CSA (Class 1, Zone 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpares \u0026amp; Components\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e126599-01\u003c\/td\u003e\n\u003ctd\u003eAero GT I\/O Module Internal Terminations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e143490-01\u003c\/td\u003e\n\u003ctd\u003e3500\/44M Aeroderivitive GT Vibration Monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e143491-01\u003c\/td\u003e\n\u003ctd\u003e3500\/44M Aeroderivitive GT Vibration Monitor User Guide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e140471-01\u003c\/td\u003e\n\u003ctd\u003eProx\/Velom I\/O Module with Internal Terminations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e140482-01\u003c\/td\u003e\n\u003ctd\u003eProx\/Velom I\/O Module with External Terminations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e169459-01\u003c\/td\u003e\n\u003ctd\u003eMultimode Prox\/Velom I\/O Module with Internal Terminations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e169459-02\u003c\/td\u003e\n\u003ctd\u003eMultimode Prox\/Velom I\/O Module with External Terminations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00580434\u003c\/td\u003e\n\u003ctd\u003eEuro Style connector header, 8 pin, Green\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00580432\u003c\/td\u003e\n\u003ctd\u003eEuro Style connector header, 10 pin, Green\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00561941\u003c\/td\u003e\n\u003ctd\u003eProx\/Velom and Multimode Prox\/Velom I\/O Module ten-pin connector shunt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e166M2389\u003c\/td\u003e\n\u003ctd\u003eConnector Header Push-in-Spring Type (Alternative for PN 00580434)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e166M2388\u003c\/td\u003e\n\u003ctd\u003eConnector Header Push-in-Spring Type (Alternative for PN 00580432)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAero GT I\/O Module with Internal Terminations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Signal Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAccepts 1 to 4 signals from interface modules (86517, 86497), Velomitors, and accelerometers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGreater than 95 kOhm (Proximitor and acceleration inputs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer Power Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-23 Vdc nominal at 43 mA max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecorder Voltage Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+4 to +20 mA (Output proportional to monitor full-scale; load resistance 0 to 600 Ohm, +12 Vdc range across load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRack Space Requirement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 full-height rear slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eI\/O Module Dimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241.3 mm x 24.4 mm x 99.1 mm (9.50 in x 0.96 in x 3.90 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eI\/O Module Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.45 kg (1.0 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eConnector Pin\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePWR +\u003c\/td\u003e\n\u003ctd\u003eTransducer Power Positive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePWR -\u003c\/td\u003e\n\u003ctd\u003eTransducer Power Negative\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSHLD\u003c\/td\u003e\n\u003ctd\u003eTransducer Shield\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOM\u003c\/td\u003e\n\u003ctd\u003eCommon\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCH1 - CH4\u003c\/td\u003e\n\u003ctd\u003eChannel 1 through Channel 4 Transducer Inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eINHB\u003c\/td\u003e\n\u003ctd\u003eInhibit Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRET\u003c\/td\u003e\n\u003ctd\u003eReturn\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eREC1 - REC4\u003c\/td\u003e\n\u003ctd\u003eRecorder Outputs 1 through 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSHIELD\u003c\/td\u003e\n\u003ctd\u003eSystem Ground \/ Shield Connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the module into the full-height rear slot directly behind the 3500\/44M main monitor board.\u003c\/li\u003e\n\u003cli\u003eSecure field transducer and recorder wiring using compatible Euro-style connector headers or push-in spring terminal connectors.\u003c\/li\u003e\n\u003cli\u003eConnect channel shield wires to the designated SHLD terminals on the I\/O block.\u003c\/li\u003e\n\u003cli\u003eEnsure proper insertion and torque on rear panel retaining screws to secure backplane ground connection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFCC\u003c\/strong\u003e: Complies with part 15 of the FCC Rules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC\u003c\/strong\u003e: European Community Directive 2014\/30\/EU; Standards EN 61000-6-2, EN 61000-6-4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Safety\u003c\/strong\u003e: European Community Directive LV Directive 2014\/35\/EU; Standard EN 61010-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS\u003c\/strong\u003e: European Community Directive ROHS Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaritime\u003c\/strong\u003e: DNV GL rules for classification; ABS Rules for Condition of Classification (Part 1, Steel Vessels Rules, Offshore Units and Structures)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ecNRTLus (Without Internal Barriers)\u003c\/strong\u003e: Class I, Zone 2: AEx\/Ex nA nC ic IIC T4 Gc; Class I, Zone 2: AEx\/Ex ec nC ic IIC T4 Gc; Class I, Division 2, Groups A, B, C, and D; T4 @ Ta = -20 degC to +65 degC (-4 degF to +149 degF)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ecNRTLus (With Internal Barriers)\u003c\/strong\u003e: Class I, Zone 2: AEx\/Ex nA nC ic [ia Ga] IIC T4 Gc; Class I, Zone 2: AEx\/Ex ec nC ic [ia Ga] IIC T4 Gc; Class I, Division 2, Groups A, B, C, and D (W\/ IS Output for Division 1); T4 @ Ta = -20 degC to +65 degC (-4 degF to +149 degF)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX\/IECEx (Without Internal Barriers)\u003c\/strong\u003e: Ex II 3 G; Ex nA nC ic IIC T4 Gc; Ex ec nC ic IIC T4 Gc; T4 @ Ta = -20 degC to +65 degC (-4 degF to +149 degF)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX\/IECEx (With Internal Barriers)\u003c\/strong\u003e: Ex II (1) G; Ex nA nC ic [ia Ga] IIC T4 Gc; Ex ec nC ic [ia Ga] IIC T4 Gc; T4 @ Ta = -20 degC to +65 degC (-4 degF to +149 degF)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666854769003,"sku":"126599-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-126599-01-aero-gt-i-o-module-dj13igkyjdd_d5a289e7-dadc-46da-9523-073c47c97f8f.jpg?v=1765449147"},{"product_id":"bently-nevada-169459-01-3500-44m-multimode-prox-velom-i-o-module-with-internal-terminations","title":"Bently Nevada 169459-01 3500\/44M Multimode Prox\/Velom I\/O Module with Internal Terminations","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 169459-01\u003c\/strong\u003e is a \u003cstrong\u003evibration monitoring I\/O module\u003c\/strong\u003e designed for \u003cstrong\u003eaeroderivative gas turbine vibration monitoring systems\u003c\/strong\u003e within the 3500 Machinery Protection System. Installed in a full-height rear slot of the 3500 rack, it serves as the rear interface card for the \u003cstrong\u003e3500\/44M\u003c\/strong\u003e Aeroderivative GT Vibration Monitor. The module processes field signals from Proximitor sensors, Velomitors, and accelerometers with a high input impedance. Onboard internal termination headers allow direct wiring connection, accepting contact inputs for machine mode switching to alter alert and danger alarm parameter sets, while sending current outputs through 4 to 20 mA recorder channels.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIntegrates directly into a single full-height rear slot of the 3500 system rack\u003c\/li\u003e\n\u003cli\u003eFeatures internal termination headers with Euro-Style or Push-in-Spring connector options for direct transducer and system wiring\u003c\/li\u003e\n\u003cli\u003eInterfaces with Proximitor sensors, Velomitor sensors, and accelerometers for aeroderivative gas turbine monitoring\u003c\/li\u003e\n\u003cli\u003eSupports multimode machine operation by accepting external mode switching contacts to toggle between up to eight alarm parameter sets\u003c\/li\u003e\n\u003cli\u003eProvides dedicated +4 to +20 mA recorder output channels proportional to overall monitor full-scale values\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAeroderivative gas turbine machinery protection and vibration monitoring\u003c\/li\u003e\n\u003cli\u003eDynamic signal processing for Proximitor, Velomitor, and accelerometer transducer loops\u003c\/li\u003e\n\u003cli\u003eMulti-mode machine operation tracking with automated alarm setpoint switching\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003ePart Number \/ Option\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/44-07-BB\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMultimode Prox\/Velom I\/O Module with Internal Terminations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e169459-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMultimode Prox\/Velom I\/O Module with Internal Terminations (Spare Part)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e00580434\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEuro Style connector header, 8 pin, Green (For I\/O modules with internal terminations)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e00580432\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEuro Style connector header, 10 pin, Green (For I\/O modules with internal terminations)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e00561941\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProx\/Velom and Multimode Prox\/Velom I\/O Module ten-pin connector shunt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e166M2389\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConnector Header, Push-in-Spring Type (Alternative for PN 00580434)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e166M2388\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConnector Header, Push-in-Spring Type (Alternative for PN 00580432)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManufacturer Name\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (a Baker Hughes Company)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInput Impedance (Prox\/Accel)\u003c\/td\u003e\n\u003ctd\u003e10 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInput Impedance (Velomitor)\u003c\/td\u003e\n\u003ctd\u003e3.5 MOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMultimode Aeroderivative Sensitivity\u003c\/td\u003e\n\u003ctd\u003e3.94 mV\/(mm\/s) (100 mV\/(in\/s)), 5.71 mV\/(mm\/s) (145 mV\/(in\/s)), 10.19 mV\/(m\/s2) (100 mV\/g), 2.55 mV\/(m\/s2) (25 mV\/g), or 1.02 mV\/(m\/s2) (10 mV\/g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransducer Power Supply\u003c\/td\u003e\n\u003ctd\u003e23 Vdc nominal at 43 mA max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRecorder Output\u003c\/td\u003e\n\u003ctd\u003e+4 to +20 mA proportional to monitor full-scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVoltage Compliance Range\u003c\/td\u003e\n\u003ctd\u003e0 to +12 Vdc across load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLoad Resistance Range\u003c\/td\u003e\n\u003ctd\u003e0 to 600 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.3662 uA per bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAccuracy (Room Temp)\u003c\/td\u003e\n\u003ctd\u003e+\/-0.25% error\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAccuracy (Over Temp)\u003c\/td\u003e\n\u003ctd\u003e+\/-0.7% error\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUpdate Rate\u003c\/td\u003e\n\u003ctd\u003e100 ms or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e241.3 mm x 24.4 mm x 99.1 mm (9.50 in x 0.96 in x 3.90 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.45 kg (1.0 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRack Requirement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSpace Requirement\u003c\/td\u003e\n\u003ctd\u003e1 full-height rear slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack Insertion\u003c\/strong\u003e: Install the module strictly in a full-height rear slot directly behind the associated \u003cstrong\u003e3500\/44M\u003c\/strong\u003e main monitor module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Wiring\u003c\/strong\u003e: Connect field transducer, recorder, and mode control wiring directly to the internal termination blocks using either Euro-Style or Push-in-Spring connector headers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eJumper Configuration\u003c\/strong\u003e: Configure module jumpers according to system channel setup prior to powering up the rack.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard Type\u003c\/th\u003e\n\u003cth\u003eDesignation \/ Specification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFCC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComplies with part 15 of FCC Rules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEuropean Community Directive 2014\/30\/EU; EN 61000-6-2, EN 61000-6-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical Safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEuropean Community Directive 2014\/35\/EU; EN 61010-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRoHS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEuropean Community Directive 2011\/65\/EU; China RoHS EFUP 15 years per SJ\/T 11364-2024\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaritime\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDNV GL rules for classification; ABS Rules for Condition of Classification Part 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHazardous Area (cNRTLus - No Barriers)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass I, Zone 2: AEx\/Ex nA nC ic IIC T4 Gc; Class I, Zone 2: AEx\/Ex ec nC ic IIC T4 Gc; Class I, Division 2, Groups A, B, C, D; T4 @ Ta = -20 degC to +65 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHazardous Area (cNRTLus - With Barriers)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass I, Zone 2: AEx\/Ex nA nC ic [ia Ga] IIC T4 Gc; Class I, Zone 2: AEx\/Ex ec nC ic [ia Ga] IIC T4 Gc; Class I, Division 2, Groups A, B, C, D (W\/ IS Output for Division 1); T4 @ Ta = -20 degC to +65 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHazardous Area (ATEX\/IECEx - No Barriers)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eII 3 G Ex nA nC ic IIC T4 Gc; Ex ec nC ic IIC T4 Gc; T4 @ Ta = -20 degC to +65 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHazardous Area (ATEX\/IECEx - With Barriers)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eII 3(1) G Ex nA nC ic [ia Ga] IIC T4 Gc; Ex ec nC ic [ia Ga] IIC T4 Gc; T4 @ Ta = -20 degC to +65 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666855522667,"sku":"169459-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-169459-01-multimode-prox-i-o-module-qmqb4cn3op4_25383307-c203-42b2-9be6-091597930ffa.jpg?v=1765449178"},{"product_id":"bently-nevada-140471-01-i-o-module-with-internal-terminations","title":"Bently Nevada 140471-01 I\/O Module with Internal Terminations","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 140471-01\u003c\/strong\u003e is an \u003cstrong\u003eI\/O Module with Internal Terminations\u003c\/strong\u003e designed for signal interfacing within the Bently Nevada 3500 Machinery Protection System. It connects field transducers—such as Proximitor sensors, acceleration sensors, Velomitor sensors, or HTVS—directly to the rear slot of compatible 3500 series monitor modules, including the 3500\/42M Proximitor Seismic Monitor and 3500\/72M Recip Rod Position Monitor.\u003c\/p\u003e\n\u003cp\u003eThe module provides power supply parameters to connected transducers androutes input signals to the main monitor board for signal conditioning, vibration evaluation, position measurement, and alarm setpoint comparison. Equipped with internal termination headers, the \u003cstrong\u003e140471-01\u003c\/strong\u003e accepts direct field wiring without requiring separate external termination blocks.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProvides direct internal screw-terminal wiring connections for field transducer wiring.\u003c\/li\u003e\n\u003cli\u003eOccupies one full-height rear chassis slot in the Bently Nevada 3500 system rack.\u003c\/li\u003e\n\u003cli\u003eDelivers nominal -24 Vdc transducer power supply output to connected proximity and seismic sensors.\u003c\/li\u003e\n\u003cli\u003eFeatures configurable jumpers for proximity, accelerometer, and Velomitor transducer selections.\u003c\/li\u003e\n\u003cli\u003eAccommodates Euro Style 8-pin green connector headers (PN 00580434) for field connections.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMachinery protection and condition monitoring in Bently Nevada 3500 series racks.\u003c\/li\u003e\n\u003cli\u003eSignal interfacing for 3500\/42M Proximitor Seismic Monitors.\u003c\/li\u003e\n\u003cli\u003eSignal interfacing for 3500\/72M Recip Rod Position Monitors.\u003c\/li\u003e\n\u003cli\u003eDirect field sensor wiring termination in industrial control environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eParameter \/ Value\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBasic Information\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e140471-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003eI\/O Module with Internal Terminations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhysical Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSlot Requirement\u003c\/td\u003e\n\u003ctd\u003e1 full-height rear slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e241.3 mm x 24.4 mm x 99.1 mm (9.50 in x 0.96 in x 3.90 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.20 kg (0.44 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer Power Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransducer Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e-24 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eSupply Parameters (Prox \/ Accel)\u003c\/td\u003e\n\u003ctd\u003eVoltage: 23.9 V, Current: 45.5 mA, Power: 1.09 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eSupply Parameters (Velomitor)\u003c\/td\u003e\n\u003ctd\u003eVoltage: 23.9 V, Current: 45.5 mA, Power: 1.09 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental Limits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-30 degC to +65 degC (-22 degF to +150 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC (-40 degF to +185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Connector Headers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard Euro Style (8-pin, Green)\u003c\/td\u003e\n\u003ctd\u003ePart Number 00580434\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eStandard Euro Style (3-pin, Green)\u003c\/td\u003e\n\u003ctd\u003ePart Number 00580441\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003ePush-in-spring Type\u003c\/td\u003e\n\u003ctd\u003ePart Number 166M2389 (Alternative to 00580434)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003ePush-in-spring Type\u003c\/td\u003e\n\u003ctd\u003ePart Number 166M4363 (Alternative to 00580441)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the module into a dedicated full-height rear slot of the Bently Nevada 3500 rack.\u003c\/li\u003e\n\u003cli\u003eEnsure proper jumper positioning on the module circuit board corresponding to the connected transducer type (e.g., Prox\/Accel or Velomitor) prior to operation.\u003c\/li\u003e\n\u003cli\u003eWire field transducers to the green Euro Style terminal connector headers according to the channel pinout definitions.\u003c\/li\u003e\n\u003cli\u003eSecure the terminal connector headers firmly to the rear panel of the I\/O module using the integral retention screws.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification \/ Standard\u003c\/th\u003e\n\u003cth\u003eSpecification \/ Approval\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC Directive\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEuropean Community Directive 2014\/30\/EU; EN 61000-6-2, EN 61000-6-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical Safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEuropean Community Directive 2014\/35\/EU; EN 61010-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHazardous Area (cNRTLus)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass I, Zone 2: AEx\/Ex nA nC ic IIC T4 Gc; Class I, Zone 2: AEx\/Ex ec nC ic IIC T4 Gc; Class I, Division 2, Groups A, B, C, D (Ta = -20 degC to +65 degC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHazardous Area (ATEX\/IECEx)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEx nA nC ic IIC T4 Gc; Ex ec nC ic IIC T4 Gc (Ta = -20 degC to +65 degC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRoHS Directive 2011\/65\/EU; China RoHS EFUP 15 years (SJ\/T 11364-2024)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666858701163,"sku":"140471-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-140471-01-proximitor-seismic-monitor-dmc5umdfwfz_d36390ff-d6f7-4ef9-a381-63f1ebe812c5.jpg?v=1765449246"},{"product_id":"bently-nevada-125720-02-3500-32m-4-channel-relay-output-module","title":"Bently Nevada 125720-02 3500\/32M 4-Channel Relay Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e125720-02\u003c\/strong\u003e is the dedicated full-height rear I\/O 4-Channel Relay Output Module required for hazardous area (Class I, Division 2 \/ Zone 2) and SIL functional safety applications in the Bently Nevada 3500 Machinery Protection System. Installed in the rear slot directly behind its corresponding \u003cstrong\u003e149986-02\u003c\/strong\u003e front relay control module, the \u003cstrong\u003e125720-02\u003c\/strong\u003e provides four single-pole, double-throw (SPDT) relay outputs for machine protection and shutdown logic. Each channel features switch-selectable operation and integrated arc suppression, with voltage and spacing compliance specifically rated for hazardous environments.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSpecialized rear I\/O configuration for hazardous area (Class I, Div 2 \/ Zone 2) and SIL functional safety compliance\u003c\/li\u003e\n\u003cli\u003eDirect interface with the \u003cstrong\u003e149986-02\u003c\/strong\u003e front 4-channel relay control module\u003c\/li\u003e\n\u003cli\u003eFour single-pole, double-throw (SPDT) relay channel connections\u003c\/li\u003e\n\u003cli\u003eEpoxy-sealed standard relays with internal 250 Vrms arc suppressors\u003c\/li\u003e\n\u003cli\u003eBuilt-in DIP switch selection for Normally De-energized (NDE) or Normally Energized (NE) operation\u003c\/li\u003e\n\u003cli\u003eRemovable terminal block connections for simplified field wiring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMachinery protection and emergency shutdown systems (ESD)\u003c\/li\u003e\n\u003cli\u003eRotating equipment monitoring in Class I, Division 2 \/ Zone 2 hazardous areas\u003c\/li\u003e\n\u003cli\u003eFunctional safety (SIL) rated turbine, compressor, and pump protection loops\u003c\/li\u003e\n\u003cli\u003eAutomated alarm and trip relay outputs in 3500 system racks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eComponent\u003c\/th\u003e\n\u003cth\u003ePart Number\u003c\/th\u003e\n\u003cth\u003eSelection \/ Function\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHazardous\/SIL Rear I\/O Module\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e125720-02\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSpare 4-Channel Relay Output Module (Hazardous Area \/ SIL Systems)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMatching Front Control Module\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e149986-02\u003c\/td\u003e\n\u003ctd\u003eSpare 4-Channel Relay Control Module (Front Slot)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eComplete System Ordering Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500\/32-01-01 \/ 3500\/32-01-02\u003c\/td\u003e\n\u003ctd\u003e3500\/32M Relay Module with 4-Channel Output \u0026amp; Hazardous Approval\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRequired Field Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e00580436\u003c\/td\u003e\n\u003ctd\u003e6-position green terminal header (or 166M2390 push-in spring type)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4-Channel Relay Output Module (Rear I\/O)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.8 Watts typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelay Contact Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle-pole, double-throw (SPDT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArc Suppressor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 Vrms, standard installed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContact Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100,000 cycles @ 5 A, 24 Vdc or 240 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Switched Voltage (Hazardous\/SIL)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 Vdc \/ 30 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Switched Current (Hazardous\/SIL)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 A @ 0V to 30 Vdc \/ 2 A @ 30 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Switched Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 mA @ 12 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 degC to +65 degC (-22 degF to +150 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC (-40 degF to +185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRack Space Requirement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 full-height rear slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241 mm x 24.4 mm x 99.1 mm (9.50 in. x 0.96 in. x 3.90 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.4 kg (1.0 lb.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eTerminal Pin\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNC\u003c\/td\u003e\n\u003ctd\u003eNormally Closed relay contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eARM\u003c\/td\u003e\n\u003ctd\u003eRelay Armature \/ Common contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNO\u003c\/td\u003e\n\u003ctd\u003eNormally Open relay contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Mode Switch\u003c\/td\u003e\n\u003ctd\u003eSelection switch for Normally De-energized (NDE) or Normally Energized (NE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInsert the \u003cstrong\u003e125720-02\u003c\/strong\u003e into the rear full-height slot directly aligned with the \u003cstrong\u003e149986-02\u003c\/strong\u003e front control module.\u003c\/li\u003e\n\u003cli\u003eSet the relay mode selection DIP switches (NE\/NDE) on the rear I\/O card prior to wiring.\u003c\/li\u003e\n\u003cli\u003eConnect field relay conductors using green 6-position terminal headers.\u003c\/li\u003e\n\u003cli\u003eObserve strict maximum operating voltage limits of 30 Vdc or 30 Vac to maintain hazardous area and SIL certifications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ecNRTLus\u003c\/strong\u003e: Class I, Zone 2: AEx\/Ex nA nC ic IIC T4 Gc; Class I, Zone 2: AEx\/Ex ec nC ic IIC T4 Gc; Class I, Division 2, Groups A, B, C, and D; T4 @ Ta = -20 degC to +65 degC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX\/IECEx\u003c\/strong\u003e: Ex II 3 G; Ex nA nC ic IIC T4 Gc; Ex ec nC ic IIC T4 Gc; T4 @ Ta = -20 degC to +65 degC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC \/ Safety\u003c\/strong\u003e: Directive 2014\/30\/EU (EN 61000-6-2, EN 61000-6-4), Directive 2014\/35\/EU (EN 61010-1), RoHS 2011\/65\/EU\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666858930539,"sku":"125720-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-125720-02-relay-output-module-dbpympnmaht_f6ece366-393c-4bfa-ad96-333a782dd976.jpg?v=1765449249"},{"product_id":"bently-nevada-3500-40m-125680-01-proximitor-i-o-module","title":"Bently Nevada 3500\/40M 125680-01 Proximitor I\/O Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"citation-127\"\u003eThe Bently Nevada\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e125680-01\u003c\/strong\u003e\u003cspan class=\"citation-127 citation-end-127\"\u003e\u003cspan\u003e \u003c\/span\u003eis a 4-channel Proximitor I\/O Module with Internal Terminations engineered for the 3500 Series Machinery Protection System.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eSeated in the rear slot of the 3500 instrumentation rack, this module serves as the direct hardware interface linking external eddy current proximity transducers to the front-facing 3500\/40M Proximitor Monitor module.\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"citation-126 citation-end-126\"\u003eThe unit provides stable sensor power excitation, receives raw analog displacement voltages, and channels these conditioned paths into the main processor card to calculate machinery metrics like radial vibration, shaft eccentricity, thrust position, differential expansion, and REBAM.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eArmed with an integrated screw-terminal block, the 125680-01 eliminates the need for separate external termination panels, saving critical footprint space within dense control room cabinets.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3500\/40M (Rear Component)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePart Number \/ ID\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e125680-01\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProximitor I\/O Module (Internal Terminations)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3500 Series Machinery Protection System\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eChannel Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 Non-Isolated Proximity Transducer Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSignal Input Impedance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 kΩ for Proximitor Inputs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTermination Connection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBuilt-in Multi-position Screw Terminal Block\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.7 Watts Typical\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTransducer Support\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada 3300 XL 8mm, 11mm, and 25mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMeasurements\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRadial Vibration, Thrust, Eccentricity, REBAM\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions (WxHxD)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24.4 mm x 241.3 mm x 99.1 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Net Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.20 kg (0.44 lb)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnited States (USA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eTurbomachinery monitoring hardware modifications dictate checking explicit spare part numbers. Procure replacements strictly matching the factory ordering codes below.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMain System Component Suffix:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3500\/40M\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFactory Order Part Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e125680-01\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Core Variant:\u003c\/strong\u003e\u003cspan class=\"citation-125 citation-end-125\"\u003e\u003cspan\u003e \u003c\/span\u003eStandard Full-Height Rear I\/O Module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Notes \u0026amp; Field Wiring Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eTransducer Signal Termination Layout\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe internal termination block of the 125680-01 handles up to four field proximity sensor arrays. Each signal channel grouping contains three dedicated screw terminals:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVTX \/ Prox (+):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTransducer power supply voltage rail (typically -24V DC excitation).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSIG \/ In (S):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eContinuous analog raw gap voltage returned from the Proximitor sensor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCOM \/ Gnd (-):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCommon instrumentation reference return line.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eStrip conductor insulation back exactly 7 mm. Use high-grade 3-wire twisted-shielded instrumentation cables (18 AWG to 22 AWG copper) to prevent magnetic induction anomalies from distorting high-frequency signals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Shield Grounding Protocols\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTerminate individual outer cable shields at the 3500 chassis frame to prevent EMI\/RFI noise. Shield lines must be bundled and bonded to the unpainted rack frame grounding bar using a wide-surface ground clamp.\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNever\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003etie the cable shield into the terminal block's signal common (COM) screws; doing so generates ground loops that can mask critical high-amplitude vibrations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLive-Swapping Safety Constraints\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 3500 architecture allows hot-swapping; however, pulling a rear I\/O module immediately cuts excitation power to field sensors, triggering a \"Monitor Fault.\"\u003c\/p\u003e\n\u003col class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eToggle the rack’s front keylock switch to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\"PROGRAM\"\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emode.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-124\"\u003eEnable software channel\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003ebypass flags\u003c\/strong\u003e\u003cspan class=\"citation-124 citation-end-124\"\u003e\u003cspan\u003e \u003c\/span\u003evia the 3500 Rack Configuration Software.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProceed with physical removal to prevent downstream emergency trip relays from activating.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003chr\u003e\n\u003ch3\u003eMaintenance \u0026amp; Troubleshooting FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the primary difference between the 125680-01 and external termination modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The 125680-01 contains built-in screw terminal arrays on its back faceplate, allowing field wiring to anchor directly to the module. External termination variants require high-density multi-pin ribbon cables to connect to a separate DIN-rail terminal panel mounted elsewhere.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the 125680-01 module accept signals from non-Bently Nevada proximity sensors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. Internal pathways and scaling matrices are calibrated specifically for Bently Nevada proximity transducers. Third-party probes will break linear scale factors, invalidating measurement conversions and generating calibration errors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How do you troubleshoot an individual channel showing a persistent \"NOT OK\" status?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Measure the raw DC gap voltage across the SIG and COM terminals with a multimeter. A healthy probe displays between -4V DC and -16V DC. If the voltage is near 0V or mirrors the full -24V supply, the fault is likely a cable short or open conductor in the field rather than an I\/O module failure.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666859290987,"sku":"125680-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-125680-01-proximitor-i-o-module-nch0io30ar2_8104b65d-e1e6-431e-b4e2-7a9ec8d0e125.jpg?v=1765449252"},{"product_id":"bently-nevada-125720-01-3500-32-4-channel-relay-output-module","title":"Bently Nevada 125720-01 3500\/32 4-Channel Relay Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 125720-01\u003c\/strong\u003e is a spare 4-channel relay I\/O module designed for use within the \u003cstrong\u003e3500\/32\u003c\/strong\u003e 4-Channel Relay Module system. Installed in a full-height rear slot of a 3500 rack, it provides the physical terminal interfaces to route switching outputs to external control or machinery protection equipment.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003e125720-01\u003c\/strong\u003e I\/O module operates in conjunction with the front 3500\/32 relay main module. Each of its four channels uses two single-pole, double-throw (SPDT) relays wired in a double-pole, double-throw (DPDT) configuration. Individual channels can be configured independently for Normally De-energized or Normally Energized operations and include onboard switches to select relay modes alongside standard 250 Vrms arc suppressors and epoxy environmental sealing.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEpoxy-Sealed Relay Circuits\u003c\/strong\u003e: Constructed with epoxy sealing to protect switching components from environmental exposure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Arc Suppression\u003c\/strong\u003e: Standard built-in 250 Vrms arc suppressors across relay contacts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitch-Selectable Operations\u003c\/strong\u003e: Individual channel switches allow configuration for Normally De-energized or Normally Energized modes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDPDT Relay Configuration\u003c\/strong\u003e: Employs two SPDT relays per channel combined in a double-pole, double-throw setup.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e3500 Series Machinery Protection Systems requiring discrete relay output interfaces\u003c\/li\u003e\n\u003cli\u003eAutomated machinery trip, alert logic actuation, and external control system interfacing\u003c\/li\u003e\n\u003cli\u003eIndustrial rotating equipment monitoring systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eU.S.A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSpare 4-Channel Relay I\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelay Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo SPDT relays connected in a DPDT configuration per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental Sealing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEpoxy-sealed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArc Suppressor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 Vrms, installed as standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContact Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100,000 cycles @ 5 A, 24 Vdc or 120 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperation Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch selectable per channel for Normally De-energized or Normally Energized\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Switched Power (Resistive)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC: 120 W; AC: 600 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMin Switched Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 mA @ 5 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Switched Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Switched Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC: 30 Vdc; AC: 250 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 degC to +65 degC (-22 degF to +150 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC (-40 degF to +185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241 mm x 24.4 mm x 99.1 mm (9.50 in x 0.96 in x 3.90 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.4 kg (1.0 lb.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRack Space Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 full-height rear slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlot Placement\u003c\/strong\u003e: Mount the \u003cstrong\u003e125720-01\u003c\/strong\u003e into a full-height rear slot directly behind its corresponding 3500\/32 front relay module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Connections\u003c\/strong\u003e: Connect wiring from external alarm and shutdown devices to the designated terminal connectors on the rear faceplate.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMode Selection\u003c\/strong\u003e: Set the relay mode switches on the module faceplate to Normally De-energized (NDE) or Normally Energized (NE) as required by the system control scheme.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eESD Protection\u003c\/strong\u003e: Use a single-use grounding wrist strap (p\/n 04425545) or equivalent protection when handling or installing the card.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCertification \/ Standard\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetail\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN 61010-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC Directives\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC 61000-6-4 (Radiated\/Conducted EN 55011 Class A), IEC 61000-6-2 (EN 61000-4-2, ENV 50140, ENV 50141, EN 61000-4-4, EN 61000-4-5, EN 61000-4-8, EN 61000-4-11, ENV 50204)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHazardous Area Approvals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCSA\/NRTL\/C (Class I, Div 2, Groups A, B, C, D; T4 @ Ta = -20 degC to +65 degC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666859389291,"sku":"125720-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-125720-01-relay-i-o-module-kfc5y12f2dq_7c88921d-483d-460e-98e5-bfa645a552dc.jpg?v=1765449254"},{"product_id":"bently-nevada-133434-01-3500-50m-tachometer-i-o-module","title":"Bently Nevada 133434-01 3500\/50M Tachometer I\/O Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 133434-01\u003c\/strong\u003e is a 3500\/50M Tachometer I\/O Module designed for external terminations within the Bently Nevada 3500 Monitoring System. The \u003cstrong\u003e133434-01\u003c\/strong\u003e interfaces with the 3500\/50M Tachometer main board to process input signals from up to two proximity probes or magnetic pickups to determine shaft rotative speed, rotor acceleration, or rotor direction. It routes transducer inputs, buffered transducer signals, and proportional 4 to 20 mA recorder outputs to External Termination (ET) Blocks via dedicated cabling.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal Termination Interface:\u003c\/strong\u003e Connects to external termination blocks via dedicated signal cables.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual-Channel Support:\u003c\/strong\u003e Handles inputs from up to two proximity transducers or magnetic pickups.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProportional Analog Outputs:\u003c\/strong\u003e Provides individual +4 to +20 mA recorder outputs proportional to full-scale speed or acceleration ranges.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuffered Signal Routing:\u003c\/strong\u003e Routes buffered transducer signals to external termination points.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRear-Slot Installation:\u003c\/strong\u003e Mounts in 1 full-height rear slot of the 3500 system rack.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTurbomachinery rotative speed monitoring\u003c\/li\u003e\n\u003cli\u003eRotor acceleration and speed band measurement\u003c\/li\u003e\n\u003cli\u003eReverse rotation detection and zero speed notification\u003c\/li\u003e\n\u003cli\u003eIndustrial machinery monitoring requiring external terminal wiring configurations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003ePart Number \/ Option\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e133434-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eI\/O Module with External Terminations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/50-02-BB\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500\/50M Tachometer Module with I\/O Module with External Terminations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e125808-05\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTachometer ET Block (Euro Style connectors)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e128015-05\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTachometer ET Block (Terminal Strip connectors)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e128702-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRecorder ET Block (Euro Style connectors)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e128710-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRecorder ET Block (Terminal Strip connectors)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e135101-AAAA-BB\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500 Tachometer Signal to ET Block Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e129529-AAAA-BB\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500 Recorder Output to ET Block Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e133434-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTachometer I\/O Module with External Terminations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRack Space Requirement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 full-height rear slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241.3 mm x 24.4 mm x 99.1 mm (9.50 in x 0.96 in x 3.90 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.20 kg (0.44 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Signal Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+10.0 V to -24.0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 k Ohm (standard)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer Power Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 Vdc, 40 mA maximum per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecorder Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+4 to +20 mA (Load resistance 0 to 600 Ohm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the I\/O module in 1 full-height rear slot corresponding directly to the slot containing the 3500\/50M Tachometer Monitor Module on the front of the rack.\u003c\/li\u003e\n\u003cli\u003eWhen using External Termination I\/O modules, External Termination Blocks and signal cables must be ordered separately.\u003c\/li\u003e\n\u003cli\u003eExternal Termination Blocks cannot be used with Internal Termination I\/O modules.\u003c\/li\u003e\n\u003cli\u003eUse Bussed External Termination Blocks with TMR I\/O modules only.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC:\u003c\/strong\u003e European Community Directive 2014\/30\/EU; Standards: EN 61000-6-2, EN 61000-6-4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Safety:\u003c\/strong\u003e European Community Directive 2014\/35\/EU; Standard: EN 61010-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e European Community Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChina RoHS:\u003c\/strong\u003e Cables EFUP designation of 15 years per SJ\/T 11364-2024\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaritime:\u003c\/strong\u003e DNV GL rules for classification; ABS Rules for Condition of Classification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ecNRTLus (Non-barrier options):\u003c\/strong\u003e Class I, Zone 2: AEx\/Ex nA nC ic IIC T4 Gc; AEx\/Ex ec nC ic IIC T4 Gc; Class I, Division 2, Groups A, B, C, and D (T4 @ Ta = -20 degC to +65 degC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX\/IECEx (Non-barrier options):\u003c\/strong\u003e II 3 G Ex nA nC ic IIC T4 Gc; Ex ec nC ic IIC T4 Gc (T4 @ Ta = -20 degC to +65 degC)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666859487595,"sku":"133434-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-133434-01-tachometer-i-o-module-3c3j5gb4y0p_3594324a-d219-4a55-8f2d-09f7aa724d67.jpg?v=1765449258"},{"product_id":"bently-nevada-126632-01-3500-45-bussed-tmr-position-i-o-module","title":"Bently Nevada 126632-01 3500\/45 Bussed TMR Position I\/O Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 126632-01\u003c\/strong\u003e is a Bussed Triple Modular Redundant (TMR) Position Input\/Output Module designed for rear-slot installation in a 3500 Series machinery protection rack. Operating in conjunction with the \u003cstrong\u003e3500\/45\u003c\/strong\u003e Position Monitor, the \u003cstrong\u003e126632-01\u003c\/strong\u003e conditions signal inputs from proximity transducers to provide continuous machinery protection, axial thrust measurement, differential expansion, and vibration monitoring for critical rotating assets. The module connects to External Termination Blocks to route signal inputs and recorder outputs, ensuring high availability and fault-tolerant operation in fault-critical applications.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBussed TMR Support:\u003c\/strong\u003e Enables Triple Modular Redundant processing across three monitor channels for fault-tolerant operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal Termination Design:\u003c\/strong\u003e Utilizes external termination blocks and cabling to simplify field wiring and maintain rack modularity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProximitor Compatibility:\u003c\/strong\u003e Specialized interface dedicated for use with Proximitor transducer inputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFull-Height Form Factor:\u003c\/strong\u003e Designed for direct insertion into a single full-height rear rack slot of a 3500 system.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTurbine axial (thrust) position monitoring\u003c\/li\u003e\n\u003cli\u003eSingle and dual ramp differential expansion measurement\u003c\/li\u003e\n\u003cli\u003eComplementary Input Differential Expansion (CIDE)\u003c\/li\u003e\n\u003cli\u003eIndustrial rotating equipment protection in power generation, oil \u0026amp; gas, and petrochemical plants\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e126632-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBussed TMR Position I\/O Module with External Terminations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProximitor inputs only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer Power Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-24 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eI\/O Module Dimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241.2 mm x 24.4 mm x 99.1 mm (9.50 in x 0.96 in x 3.90 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eI\/O Module Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.45 kg (1.0 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRack Space Requirement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 full-height rear slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 degC to +65 degC (-22 degF to +150 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC (-40 degF to +185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack Mounting:\u003c\/strong\u003e Install the module into a single full-height rear slot corresponding to the associated \u003cstrong\u003e3500\/45\u003c\/strong\u003e Position Monitor front card.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCabling:\u003c\/strong\u003e Use dedicated 3500 transducer signal cables (129525-AXXXX-BXX series) to connect the module to the external termination block.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal Terminations:\u003c\/strong\u003e Required external termination blocks (such as 132242-01 or 132234-01) and cables must be ordered separately.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Requirements:\u003c\/strong\u003e Ensure the 3500 Rack Interface Module (RIM) firmware is revision G or later and 3500 Configuration Software version 2.41 or higher is installed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA\/NRTL\/C:\u003c\/strong\u003e Class 1, Div 2, Groups A, B, C, D; T4 @ Ta = -20 degC to +65 degC (-4 degF to +150 degF); Certification CSA 150268-1002151 (LR 26744)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE Mark Directives:\u003c\/strong\u003e EMC Directives EN 61000-6-4, EN 55011 Class A, EN 61000-6-2, EN 61010-1\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666859520363,"sku":"126632-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-126632-01-tmr-i-o-module-2vhwxnwtvb5_186fb792-06ab-4af0-adc9-e38594b96680.jpg?v=1765449260"},{"product_id":"bently-nevada-133396-01-overspeed-detection-i-o-module","title":"Bently Nevada 133396-01 Overspeed Detection I\/O Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 133396-01\u003c\/strong\u003e is an Overspeed Detection I\/O Module designed for use in the 3500 Series Machinery Detection System. It serves as a rear I\/O interface for the 3500\/53 Electronic Overspeed Detection System, providing critical signal routing, power supply conditioning, and interface connections for tachometer protection applications.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003e133396-01\u003c\/strong\u003e module interfaces with proximity probes or passive magnetic pickups to supply a -24 Vdc power source to transducers and routes proportional +4 to +20 mA recorder output values corresponding to system full-scale speed (rpm). It is epoxy-sealed for environmental protection and operates within 3500 racks configured with redundant power supplies to meet API 670 and API 612 standard requirements for highly reliable machinery overspeed protection.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEpoxy-Sealed Construction\u003c\/strong\u003e: Designed with epoxy sealing to protect internal circuitry from environmental exposure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Transducer Power Supply\u003c\/strong\u003e: Delivers -24 Vdc power directly to connected proximity transducers or sensors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProportional Recorder Output\u003c\/strong\u003e: Provides a +4 to +20 mA current output proportional to the module's full-scale speed range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort-Circuit Immunity\u003c\/strong\u003e: Operation remains unaffected by potential short circuits on the recorder output line.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundant System Integration\u003c\/strong\u003e: Designed for full integration with 3500\/53 monitor modules in 2-out-of-2 or 2-out-of-3 voting architectures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAPI 670 and API 612 compliant machinery overspeed protection systems\u003c\/li\u003e\n\u003cli\u003eSteam turbine, gas turbine, and industrial rotating equipment monitoring\u003c\/li\u003e\n\u003cli\u003e3500 Series Machinery Detection System installations requiring rear I\/O signal interfaces\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e133396-01\u003c\/td\u003e\n\u003ctd\u003eOverspeed Detection I\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eU.S.A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.0 watts, typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer Power Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-24 Vdc, 40 mA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental Sealing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEpoxy sealed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecorder Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+4 to +20 mA (Proportional to full-scale rpm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecorder Output Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnaffected by short circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.45 kg (1.0 lb.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241.3 mm x 24.4 mm x 99.1 mm (9.50 in x 0.96 in x 3.90 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRack Space Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 full-height rear slot per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack Location\u003c\/strong\u003e: Install the \u003cstrong\u003e133396-01\u003c\/strong\u003e module into a full-height rear slot corresponding directly to the 3500\/53 main monitor module slot location.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply Requirements\u003c\/strong\u003e: Verify that the host 3500 rack utilizes redundant power supplies as required for overspeed protection applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eESD Precautions\u003c\/strong\u003e: Use a single-use grounding wrist strap (p\/n 04425545) or equivalent ESD protection during handling and installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Terminations\u003c\/strong\u003e: Ensure signal and power cabling are connected securely using compatible terminal block connector headers.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCertification \/ Standard\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetail\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN 61010-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC Directives\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN 50081-2, EN 50082-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHazardous Area Approvals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCSA\/NRTL\/C (Class I, Div 2, Groups A, B, C, D; T4 @ Ta = -20 degC to +65 degC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndustry Standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAPI 670, API 612 compliant system component\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666859618667,"sku":"133396-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-133396-01-overspeed-detection-i-o-module-524g4w1camw_79def0b6-6d50-405d-990e-7593339575e6.jpg?v=1765449262"},{"product_id":"bently-nevada-81544-01-3300-transducer-input-output-and-recorder-terminal-module","title":"Bently Nevada 81544-01 3300 Transducer Input\/Output and Recorder Terminal Module","description":"\u003cp\u003eThe \u003cstrong\u003e81544-01\u003c\/strong\u003e Transducer Input\/Output and Recorder Terminal Module, alternative factory part number \u003cstrong\u003e78462-02\u003c\/strong\u003e, is a rear-mounting interface component engineered exclusively for the Bently Nevada 3300\/45 Dual Differential Expansion Monitor within a Turbine Supervisory Instrumentation system. The module facilitates the dual-channel routing of dynamic signal inputs from two separate proximity probe transducer setups to evaluate absolute axial rotor displacement relative to the machine casing caused by thermal expansion during startup and shutdown. Electrically configured with a fixed input impedance of 10 kΩ, it supports the monitor's control logic which processes both the magnitude and direction of differential expansion across four programmable alert thresholds consisting of two over-alarm and two under-alarm setpoints. This passive terminal architecture is executed without onboard electromechanical relay contacts, operating instead as a direct signal pass-through and recorder distribution hub for continuous machinery protection.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e81544-01 (78462-02)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300 System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Monitor Module\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300\/45 Dual Differential Expansion Monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannel Count\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 Independent channels (Channel B can be turned OFF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer Interfacing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 Proximity probe transducer signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAlarm Capacity Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 Setpoints total (2 Over-alarms, 2 Under-alarms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelay Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo onboard relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Manufacture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnited States (USA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEngineering Notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe 10 kΩ input impedance is optimized to match the output parameter of standard Bently Nevada Proximitor sensors, ensuring zero signal degradation across the differential expansion measurement arc.\u003c\/li\u003e\n\u003cli\u003eWhen single-point axial measurements are required on smaller machine casings, Channel B must be programmatically disabled within the 3300\/45 monitor to suppress open-circuit gap voltage faults.\u003c\/li\u003e\n\u003cli\u003eBecause the 81544-01 contains no mechanical relays, all interlocking alarm and trip execution commands must be processed via the system backplane to an adjacent 3300 system relay module.\u003c\/li\u003e\n\u003cli\u003eThermal expansion changes during turbine ramp-up alter the baseline gap voltage; raw recorder outputs from this terminal map these proportional DC shifts for trend plotting.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eImplement rigorous shield grounding at the designated terminal strip block, ensuring the outer shield drain wire of the proximity probe extension cable is tied to instrument ground while remaining isolated at the sensor housing.\u003c\/li\u003e\n\u003cli\u003eMaintain separate wire routing paths for the low-impedance sensor inputs and any neighboring high-voltage AC control circuits to avoid cross-talk within the TSI panel enclosure.\u003c\/li\u003e\n\u003cli\u003ePrior to commissioning, verify that terminal lug screws are tightened to standard torque specifications to eliminate intermittent gap voltage fluctuations caused by physical contact resistance.\u003c\/li\u003e\n\u003cli\u003eEnsure proper spacing and mechanical alignment when sliding the 81544-01 terminal block onto the rear rack connectors to prevent pin distortion or open circuit paths on the 3300 backplane.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical \u0026amp; Procurement FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the 81544-01 terminal block module include mechanical relay contacts for driving local trip solenoids?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No, the 81544-01 is designated as a No Relays module; it routes raw transducer and recorder signals, relying on the 3300 backplane to pass alarm states to a dedicated relay module.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this component be utilized with any standard 3300 series proximity probe monitor, such as a radial vibration module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No, this part number is mapped directly to the hardware parameters of the 3300\/45 Dual Differential Expansion Monitor and cannot be substituted into other monitoring slots.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the technical function of the alternate part number 78462-02 listed on the assembly?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The number 78462-02 represents the bare raw board or sub-assembly designation used during production, which corresponds identically to the complete top-level part number 81544-01.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666860306795,"sku":"81544-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-81544-01-xducr-i-o-and-record-terminals-phquym4p1wm_e2995e0f-7667-420e-acd8-3471ac8b1dcc.jpg?v=1765449280"},{"product_id":"bently-nevada-106m1081-01-3500-15-universal-ac-power-input-module","title":"Bently Nevada 106M1081-01 3500\/15 Universal AC Power Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e106M1081-01\u003c\/strong\u003e Universal AC Power Input Module (PIM) is a rear-mount power interface module engineered for the \u003cstrong\u003eBently Nevada 3500\/15\u003c\/strong\u003e AC and DC Power Supplies system. Positioned in the rear slot directly behind its associated front-facing power supply module, the \u003cstrong\u003e106M1081-01\u003c\/strong\u003e receives line AC power and routes it to the \u003cstrong\u003e106M1079-01\u003c\/strong\u003e Universal AC Power Supply module. It converts incoming AC line voltage into acceptable operating levels for the 3500 Series Machinery Protection System rack. Note that the \u003cstrong\u003e106M1081-01\u003c\/strong\u003e Universal AC PIM is not compatible with legacy 3500 AC power supplies or legacy AC power input modules.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAccepts nominal 110 to 220 Vac input with wide operating limits (85 to 264 Vac rms for non-hazardous areas, 85 to 250 Vac rms for hazardous areas).\u003c\/li\u003e\n\u003cli\u003eDedicated half-height module design installed directly behind the matching front-facing power supply module.\u003c\/li\u003e\n\u003cli\u003eOperates in combination with the 3500\/15 Universal AC Power Supply module (\u003cstrong\u003e106M1079-01\u003c\/strong\u003e).\u003c\/li\u003e\n\u003cli\u003eIntegrated over-voltage protection via fuse located on the power input module.\u003c\/li\u003e\n\u003cli\u003eBuilt-in protection ensuring under-voltage conditions cause no damage to the module or power supply.\u003c\/li\u003e\n\u003cli\u003eSupports seamless module insertion and removal without interrupting rack operation in dual-redundant power configurations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAC-powered 3500 Series Machinery Protection System racks.\u003c\/li\u003e\n\u003cli\u003eTurbomachinery vibration, axial position, and condition monitoring systems.\u003c\/li\u003e\n\u003cli\u003eContinuous critical machinery protection in power generation, oil and gas, and petrochemical facilities.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada \/ Baker Hughes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e106M1081-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUniversal AC Power Input Module (PIM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500\/15 Power Supply System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Input Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110 to 220 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage Range (Non-hazardous)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 to 264 Vac rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage Range (Hazardous)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 to 250 Vac rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePeak Input Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 to 373 Vac pk\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e47 to 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull Rack Current Draw\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.8 A rms (maximum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOver-Voltage Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuse opens on the PIM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnder-Voltage Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnder-voltage does not harm supply or PIM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReplacement Fuse Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120M3877 (Fast blow rated at 5A\/500 Vac, Size 6.3 x 32 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReplacement Connector Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e118M0915-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120.7 mm x 25.4 mm x 114.3 mm (4.75 in x 1.0 in x 4.5 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.34 kg (0.75 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 degC to +65 degC (-22 degF to +150 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC (-40 degF to +185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack Mounting Location:\u003c\/strong\u003e Mount the module in the special half-height rear slot located directly behind the associated 3500\/15 Universal AC Power Supply module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundant Operations:\u003c\/strong\u003e In dual-supply rack setups, inserting or removing either power supply module will not interrupt rack operation as long as a secondary supply is active.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage and Wiring Security:\u003c\/strong\u003e Ensure AC supply lines adhere to specified input voltage limits (85 to 264 Vac rms non-hazardous \/ 85 to 250 Vac rms hazardous) and frequency range (47 to 63 Hz).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuse Maintenance:\u003c\/strong\u003e If an over-voltage condition causes the module fuse to open, replace it using verified replacement fuse part number \u003cstrong\u003e120M3877\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatibility Check:\u003c\/strong\u003e Verify that the front power supply module is the matching \u003ca href=\"https:\/\/www.plcprotech.com\/products\/bently-nevada-106m1079-01-3500-15-universal-ac-power-supply-module\"\u003e\u003cstrong\u003e106M1079-01\u003c\/strong\u003e\u003c\/a\u003e Universal AC Power Supply, as legacy AC modules are incompatible.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFCC:\u003c\/strong\u003e Part 15 Class A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Directives:\u003c\/strong\u003e European Community Directive 2014\/30\/EU; EN 61000-6-2, EN 61000-6-4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Safety:\u003c\/strong\u003e European Community Directive 2014\/35\/EU; EN 61010-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e European Community Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaritime Approvals:\u003c\/strong\u003e DNV GL rules for classification; ABS Rules for Condition of Classification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area Approvals:\u003c\/strong\u003e Class I, Zone 2: AEx\/Ex nA nC ic IIC T4 Gc; Class I, Zone 2: AEx\/Ex ec nC ic IIC T4 Gc; Class I, Division 2, Groups A, B, C, and D (T4 @ Ta = -20 degC to +65 degC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX \/ IECEx:\u003c\/strong\u003e Ex II 3 G; Ex nA nC ic IIC T4 Gc; Ex ec nC ic IIC T4 Gc (T4 @ Ta = -20 degC to +65 degC)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666860863851,"sku":"106M1081-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-106m1081-01-universal-ac-power-input-module-2iscrzxamv1_ee5a5891-57ac-4c7e-a824-63ebbae2a446.jpg?v=1765449293"},{"product_id":"bently-nevada-133827-01-3500-60-rtd-tc-non-isolated-i-o-module","title":"Bently Nevada 133827-01 3500\/60 RTD\/TC Non-Isolated I\/O  Module","description":"\u003ch3\u003eCore Product Insights\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e133827-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(133827-01) functions as a high-reliability\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/60\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRTD\/TC Non-Isolated I\/O Module designed for External Terminations. This module interfaces directly with external terminal blocks to process critical temperature inputs from Resistance Temperature Detectors (RTDs) and Thermocouples (TCs). In heavy industries such as petrochemical refining, LNG processing, and power generation, thermal anomalies indicate impending machinery failure. By delivering continuous, high-precision thermal monitoring to the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMachinery Protection System, this component prevents catastrophic failures, eliminates false trips, and significantly reduces un-scheduled industrial downtime.\u003c\/p\u003e\n\u003ch3\u003eHardware Architecture \u0026amp; Interface Options\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e133827-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ehardware is engineered for high-density signal processing within the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erack backplane. It serves as the physical link between field-mounted temperature sensors and the main\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/60\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emonitor card. The external termination architecture allows engineers to route field wiring to a separate termination block located outside the main rack enclosure. This setup simplifies high-density cabinet wiring, facilitates rapid maintenance, and improves cable management. The non-isolated circuit design relies on correct system-level grounding and external premium shielding to maintain signal integrity across long-distance industrial sensor runs.\u003c\/p\u003e\n\u003ch3\u003eCrucial Data Parameters\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e133827-01\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e3500\u003c\/strong\u003e Series Machinery Protection System\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRTD\/TC Non-Isolated I\/O Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eExternal Terminations\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.45 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e244 mm x 23 mm x 112 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-30 to +65 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to +85 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.5 W typical\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSensor Input Support\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePlatinum RTD, Copper RTD, Nickel RTD, Type E\/J\/K\/T\/S\/R Thermocouples\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the 133827-01 handle signal noise given its non-isolated design?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module relies on high-quality external shielded twisted pair cabling and a single-point industrial ground network. Engineers must ensure proper shield termination at the external block to mitigate common-mode noise interferences.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary advantage of selecting external terminations over internal ones?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eExternal terminations allow maintenance personnel to replace the I\/O module without disconnecting any field wiring. This layout drastically minimizes human wiring errors during field replacement procedures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this module mix RTD and Thermocouple inputs on the same card simultaneously?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/60\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emonitor software allows independent channel configuration. You can program specific channels for RTDs and others for Thermocouples on the same\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e133827-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003einterface.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Deployment \u0026amp; Wiring Engineering Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShielding Protocols:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGround all sensor wire shields strictly at the external termination block. Do not ground the shield at the sensor end in the field. This prevents dangerous ground loops from corrupting the micro-volt signals of the thermocouples.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTightening Torque:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen fastening the I\/O module to the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003echassis rear rails, tighten the retaining chassis screws to exactly\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0.5 N m\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eof torque to prevent backplane connector strain.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Routing Guidelines:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure the external termination cables are routed away from high-voltage AC motor lines or variable frequency drives (VFD) to protect the non-isolated circuitry from electromagnetic cross-talk.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666861289835,"sku":"133827-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-133827-01-pc-board-plc-add-on-board-taordovzb0n_6f56e6e5-a692-4318-9449-b1d0067d7924.jpg?v=1765449309"},{"product_id":"bently-nevada-115m7750-01-3500-15-high-voltage-dc-power-input-module","title":"Bently Nevada 115M7750-01 3500\/15 High Voltage DC Power Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e115M7750-01 High Voltage DC Power Input Module (PIM)\u003c\/strong\u003e is a rear-mount power interface component designed for the Bently Nevada 3500\/15 AC and DC Power Supplies system. Installed directly behind the corresponding front-facing power supply module, the \u003cstrong\u003e115M7750-01\u003c\/strong\u003e provides the primary high-voltage DC power connection and input conditioning for the 3500 Series Machinery Protection System rack.\u003c\/p\u003e\n\n\u003cp\u003eIt connects an external high-voltage DC source to the front-facing \u003cstrong\u003e114M5329-01 High Voltage DC Power Supply Module\u003c\/strong\u003e. This allows incoming voltage to be safely routed and converted for internal rack utilization.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAccepts a high-voltage DC input range from 88 Vdc to 140 Vdc.\u003c\/li\u003e\n\u003cli\u003eUses a half-height rear module footprint directly behind the associated power supply.\u003c\/li\u003e\n\u003cli\u003eWorks with the 3500\/15 High Voltage DC Power Supply Module, part number \u003cstrong\u003e114M5329-01\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eIncludes onboard fuse protection against over-voltage conditions.\u003c\/li\u003e\n\u003cli\u003eUnder-voltage conditions do not damage the module or power supply.\u003c\/li\u003e\n\u003cli\u003eSupports hot-swappable replacement in dual-redundant power configurations without interrupting rack operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-voltage DC-powered 3500 Series Machinery Protection System racks.\u003c\/li\u003e\n\u003cli\u003eTurbomachinery vibration and condition monitoring systems.\u003c\/li\u003e\n\u003cli\u003eContinuous machinery protection in oil and gas facilities.\u003c\/li\u003e\n\u003cli\u003ePower generation plants.\u003c\/li\u003e\n\u003cli\u003eChemical and process industry installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada \/ Baker Hughes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel \/ Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e115M7750-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHigh Voltage DC Power Input Module (PIM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500\/15 Power Supply System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e88 to 140 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull Rack Current Draw\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 A maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOver-Voltage Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOver-voltage causes the fuse on the PIM to open\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnder-Voltage Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnder-voltage does not damage the power supply or PIM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReplacement Fuse Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e129M0198\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H × W × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120.7 × 25.4 × 114.3 mm (4.75 × 1.0 × 4.5 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.34 kg (0.75 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30°C to +65°C (-22°F to +150°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°C to +85°C (-40°F to +185°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack Location:\u003c\/strong\u003e Install the module in the special half-height slot at the rear of the rack. It must be positioned directly behind the associated front-facing 3500\/15 High Voltage DC Power Supply Module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy Configuration:\u003c\/strong\u003e In a dual-supply system, the PIM can be inserted or replaced without interrupting rack operation, provided the second power supply remains operational.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring and Terminal Safety:\u003c\/strong\u003e Verify that the DC power connection remains within the specified 88 to 140 Vdc range. Confirm the correct polarity before applying input power.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection and Fusing:\u003c\/strong\u003e An over-voltage event will cause the PIM fuse to open. Replace it only with the specified \u003cstrong\u003e129M0198\u003c\/strong\u003e replacement fuse.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFCC:\u003c\/strong\u003e Part 15, Class A.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Directives:\u003c\/strong\u003e European Community Directive 2014\/30\/EU; EN 61000-6-2; EN 61000-6-4.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Safety:\u003c\/strong\u003e European Community Directive 2014\/35\/EU; EN 61010-1.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e European Community Directive 2011\/65\/EU.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaritime Approvals:\u003c\/strong\u003e DNV GL rules for classification; ABS Rules for Conditions of Classification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area Approvals:\u003c\/strong\u003e Class I, Zone 2: AEx\/Ex nA nC ic IIC T4 Gc; AEx\/Ex ec nC ic IIC T4 Gc; Class I, Division 2, Groups A, B, C, and D. T4 at Ta = -20°C to +65°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX \/ IECEx:\u003c\/strong\u003e II 3 G; Ex nA nC ic IIC T4 Gc; Ex ec nC ic IIC T4 Gc. T4 at Ta = -20°C to +65°C.\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666861519211,"sku":"115M7750-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-115m7750-01-dc-power-input-module-aueqymfo5xi_f16d090a-7edb-444f-bc77-627946db8204.jpg?v=1765449315"},{"product_id":"bently-nevada-149992-01-3500-33-16-channel-relay-output-module","title":"Bently Nevada 149992-01 3500\/33 16-Channel Relay Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada \u003cstrong\u003e149992-01\u003c\/strong\u003e is a 16-channel relay output module designed for machinery protection and alarm expansion within the \u003cstrong\u003e3500 Series\u003c\/strong\u003e machinery monitoring system. Installed in a full-height rear slot of the 3500 rack, the module provides 16 independent relay outputs driven by Alarm Drive Logic to execute voting schemes based on alarming inputs, Not-OK conditions, or individual measured variables from monitoring channels across the system. It features epoxy-sealed single-pole double-throw (SPDT) relays equipped with built-in 250 Vrms arc suppressors and physical switch selection for Normally Energized (NE) or Normally De-energized (NDE) operation across four distinct channel groups.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProvides 16 independently programmable single-pole double-throw (SPDT) relay output channels\u003c\/li\u003e\n\u003cli\u003eFeatures physical relay mode selection switches on the module for setting Normally Energized (NE) or Normally De-energized (NDE) operation in groups of four channels\u003c\/li\u003e\n\u003cli\u003eBuilt-in 250 Vrms relay arc suppressors installed as standard on contact outputs\u003c\/li\u003e\n\u003cli\u003eOnboard epoxy-sealed relay units designed for 10,000 cycles of contact life\u003c\/li\u003e\n\u003cli\u003eSupports independently programmed Alarm Drive Logic utilizing AND and OR voting logic configurations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTurbine machinery trip and emergency shutdown systems\u003c\/li\u003e\n\u003cli\u003eMachinery protection alarm expansion in oil and gas production\u003c\/li\u003e\n\u003cli\u003ePower generation plant rotating equipment monitoring\u003c\/li\u003e\n\u003cli\u003eIndustrial process alarm signaling and interlocking\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOrdering Option \/ Part Number\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/33-AA-BB\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500\/33 16-Channel Relay Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA: Output Module Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003e16-Channel Relay Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003e16-Channel Failsafe Relay Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e03\u003c\/td\u003e\n\u003ctd\u003eLow Current 16-Channel Relay Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e04\u003c\/td\u003e\n\u003ctd\u003eLow Current 16-Channel Failsafe Relay Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB: Hazardous Area Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eCNRTLUS (Class 1, Division 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eATEX \/ IECEx \/ CSA (Class 1, Zone 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpares\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e149986-01\u003c\/td\u003e\n\u003ctd\u003eSpare 16-Channel Relay Control Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e149992-01\u003c\/td\u003e\n\u003ctd\u003eSpare 16-Channel Relay Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e149992-02\u003c\/td\u003e\n\u003ctd\u003eSpare 16-Channel Failsafe Relay Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e149992-03\u003c\/td\u003e\n\u003ctd\u003eSpare 16-Channel Low Current Relay Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e149992-04\u003c\/td\u003e\n\u003ctd\u003eSpare 16-Channel Low Current Failsafe Relay Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e04425545\u003c\/td\u003e\n\u003ctd\u003eGrounding Wrist Strap (single use)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e162291\u003c\/td\u003e\n\u003ctd\u003e16-Channel Relay Module User Guide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00580453\u003c\/td\u003e\n\u003ctd\u003eConnector Header Internal Termination 16-position Green\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e166M2381\u003c\/td\u003e\n\u003ctd\u003eConnector Header Push-in-Spring Type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhysical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eI\/O Module Dimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e241 mm x 24.4 mm x 99.1 mm (9.50 in x 0.96 in x 3.90 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eI\/O Module Weight\u003c\/td\u003e\n\u003ctd\u003e0.4 kg (1.0 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eRack Space Requirements\u003c\/td\u003e\n\u003ctd\u003e1 full-height rear slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5.8 watts typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eRelay Type\u003c\/td\u003e\n\u003ctd\u003eSingle-pole Double-throw (SPDT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eRelay Environmental Sealing\u003c\/td\u003e\n\u003ctd\u003eEpoxy-sealed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eRelay Arc Suppressor\u003c\/td\u003e\n\u003ctd\u003e250 Vrms installed as standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eRelay Contact Life\u003c\/td\u003e\n\u003ctd\u003e10,000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard Relays (DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMin Switched Current\u003c\/td\u003e\n\u003ctd\u003e100 mA @ 5 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eMax Switched Current\u003c\/td\u003e\n\u003ctd\u003e5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eMax Switched Power\u003c\/td\u003e\n\u003ctd\u003e70 W @ 24 Vdc, 10 W @ 48 Vdc, 9 W @ 60 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eMax Switched Voltage\u003c\/td\u003e\n\u003ctd\u003e125 Vdc (30 Vdc for Failsafe\/Hazardous Area Systems)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard Relays (AC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMin Switched Current\u003c\/td\u003e\n\u003ctd\u003e100 mA @ 5 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eMax Switched Current\u003c\/td\u003e\n\u003ctd\u003e5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eMax Switched Power\u003c\/td\u003e\n\u003ctd\u003e1200 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eMax Switched Voltage\u003c\/td\u003e\n\u003ctd\u003e250 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eConnector Pin\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNC\u003c\/td\u003e\n\u003ctd\u003eNormally Closed Contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eARM\u003c\/td\u003e\n\u003ctd\u003eRelay Armature (Common Contact)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNO\u003c\/td\u003e\n\u003ctd\u003eNormally Open Contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure power to the module\/slot is disconnected prior to servicing or maintenance when installed in live environments.\u003c\/li\u003e\n\u003cli\u003eFollow static-sensitive handling procedures and utilize a grounding wrist strap during installation.\u003c\/li\u003e\n\u003cli\u003eEnsure proper terminal wiring to the 16-position internal termination green connector header or push-in spring header.\u003c\/li\u003e\n\u003cli\u003eSet the Relay Mode Selection Switch on the side of the I\/O module to NDE or NE for channels 1-4, 5-8, 9-12, and 13-16 prior to final mounting.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification \/ Standard\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFCC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComplies with Part 15 of FCC Rules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEuropean Community Directive 2014\/30\/EU; Standards: EN 61000-6-2, EN 61000-6-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical Safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEuropean Community Directive 2014\/35\/EU; Standard: EN 61010-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eROHS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEuropean Community Directive 2011\/65\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaritime\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDNV GL rules for classification; ABS Rules for Condition of Classification (Steel Vessels Rules, Offshore Units and Structures)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHazardous Area Approvals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ecNRTLus: Class I, Zone 2: AEx\/Ex nA nC ic IIC T4 Gc; Class I, Zone 2: AEx\/Ex ec nC ic IIC T4 Gc; Class I, Division 2, Groups A, B, C, D; T4 @ Ta = -20 degC to +65 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eATEX\/IECEx: Ex II 3 G, Ex nA nC ic IIC T4 Gc, Ex ec nC ic IIC T4 Gc; T4 @ Ta = -20 degC to +65 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666861945195,"sku":"149992-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-149992-01-relay-output-module-hb1n3kl13yj_c3d7b158-b5ce-414e-929f-e72c4d114be6.jpg?v=1765449325"},{"product_id":"bently-nevada-138708-01-shaft-absolute-i-o-module-with-internal-terminations","title":"Bently Nevada 138708-01 Shaft Absolute I\/O Module with Internal Terminations","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 138708-01\u003c\/strong\u003e is a Shaft Absolute I\/O Module with Internal Terminations designed for machinery protection and condition monitoring within the 3500\/42M Proximitor\/Seismic Monitor system. Interfacing directly with the 3500\/42M main monitor board via the 3500 backplane, the module routes field signals from proximity, Velomitor, or Seismoprobe transducers to condition raw signal inputs and measure critical parameters like shaft absolute vibration. The board continuously feeds static and dynamic variables to the 3500 Rack Configuration Software and host monitoring systems, providing continuous alarm setpoint evaluation against active static values to safeguard industrial rotating machinery.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDirect connection for internal field wiring terminations without requiring external termination blocks\u003c\/li\u003e\n\u003cli\u003eInput signal processing for proximity transducers, Velomitors, and Seismoprobes\u003c\/li\u003e\n\u003cli\u003eIntegrated signal routing for shaft absolute vibration measurements within the 3500\/42M Proximitor\/Seismic Monitor\u003c\/li\u003e\n\u003cli\u003eStandard 8-pin and 10-pin Euro style internal connector header compatibility\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eShaft absolute vibration measurement on industrial rotating machinery\u003c\/li\u003e\n\u003cli\u003eContinuous machinery protection and alarm monitoring\u003c\/li\u003e\n\u003cli\u003eOperations and maintenance asset condition monitoring in 3500 Series racks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOrdering Code \/ Part Number\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/42-A07-BXX\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500\/42M Monitor with Shaft Absolute I\/O Module with Internal Terminations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e138708-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShaft Absolute I\/O Module with internal terminations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e00517018\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500\/42M Shaft Absolute I\/O Module 8-pin connector shunt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e00580434\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInternal I\/O Module connector header, Euro style, 8-pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e00580432\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInternal I\/O Module connector header, Euro style, 10-pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e138708-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShaft Absolute I\/O Module with Internal Terminations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupported System\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500\/42M Proximitor\/Seismic Monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Transducers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProximity Transducers, Velomitors, Seismoprobes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Supply (Prox \u0026amp; Velomitor)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eU = 23.9 V, I = 45.5 mA, P = 1.09 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Supply (Prox \u0026amp; Seismoprobe)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eU = 6.82 V, I = 45.5 mA, P = 0.31 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFirmware Requirement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500\/42M Module Firmware, revision B or later\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSoftware Requirement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500\/01 Software version 2.61 or later; DM2000 Software version 3.10 or later\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the \u003cstrong\u003e138708-01\u003c\/strong\u003e module into the rear slot of the 3500 rack directly behind the corresponding 3500\/42M main monitor board.\u003c\/li\u003e\n\u003cli\u003eWire field transducer leads directly to the internal Euro style screw terminal connectors.\u003c\/li\u003e\n\u003cli\u003eVerify that external termination blocks are not used with this module, as it uses direct internal terminations.\u003c\/li\u003e\n\u003cli\u003eSecure the card in place using the chassis retaining screws to ensure stable ground contact through the 3500 rack frame.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard \/ Directive\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCE Directives\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCE Marked\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCSA \/ NRTL \/ C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass 1, Division 2 (Option B01)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eATEX \/ IECEx \/ CSA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass 1, Zone 2 (Option B02)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666862272875,"sku":"138708-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-138708-01-proximity-input-pkrbjapaoat_9f18948c-66c7-4082-a30b-b83460d588f6.jpg?v=1765449336"},{"product_id":"bently-nevada-135489-04-3500-40m-proximitor-i-o-module-with-internal-barriers","title":"Bently Nevada 135489-04 3500\/40M Proximitor I\/O Module with Internal Barriers","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e135489-04\u003c\/strong\u003e (135489-04) is a high-performance Input\/Output module specifically engineered for the Bently Nevada \u003cstrong\u003e3500\/40M\u003c\/strong\u003e Proximitor Monitor system. This four-channel interface is designed to bridge field transducers with the machinery protection rack, providing integrated \u003cstrong\u003eInternal Barriers\u003c\/strong\u003e and \u003cstrong\u003eInternal Terminations\u003c\/strong\u003e. This configuration is critical for hazardous area installations, as the built-in safety barriers limit electrical energy to prevent ignition in explosive atmospheres.\u003c\/p\u003e\n\u003cp\u003eThe module processes pulse and displacement signals from proximity transducers to monitor essential machinery parameters, including radial vibration, thrust position, eccentricity, differential expansion, and REBAM. By delivering continuous machinery protection and high-fidelity data to operations personnel, the \u003cstrong\u003e135489-04\u003c\/strong\u003e serves as a vital component in reducing unscheduled downtime for critical assets in power generation, oil and gas, and petrochemical processing.\u003c\/p\u003e\n\u003ch3\u003eHardware Architecture \u0026amp; Signal Processing\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e135489-04\u003c\/strong\u003e module is designed with a high-density architecture that supports up to four proximity transducer signals simultaneously. It features internal galvanic isolation and safety components that comply with CSA-NRTL\/C and ATEX\/IECEx entity parameters.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel Programming\u003c\/strong\u003e: Monitor channels are programmed in pairs, allowing the system to perform up to two distinct functions at once (e.g., Channels 1 and 2 monitoring radial vibration while Channels 3 and 4 monitor thrust).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Barriers\u003c\/strong\u003e: The module incorporates a Proximitor Barrier circuit with specific power (PWR) and signal (SIG) parameters, ensuring Vmax and Imax levels remain within safe operational limits for intrinsic safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Conditioning\u003c\/strong\u003e: The hardware provides advanced filtering capabilities, including direct filters (up to 4000 Hz), gap filters, and constant Q notch filters for 1X and 2X vector tracking.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e135489-04\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProximitor I\/O Module with Internal Barriers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Signals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 to 4 Proximity Transducers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.7 Watts Typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to +65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241.3 mm x 24.4 mm x 163.1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.46 kg (1.01 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the internal barrier affect the field wiring requirements?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003e135489-04\u003c\/strong\u003e includes built-in safety barriers, which eliminates the need for external zener barriers or galvanic isolators between the rack and the hazardous area. This simplifies cabinet layout and reduces overall loop impedance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this module be used for both radial vibration and thrust position?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The 3500\/40M monitor paired with this I\/O module allows channels to be configured in pairs for different functions, such as radial vibration on one pair and thrust position on the other.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the primary entity parameters for the internal barriers?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFor the Proximitor Barrier (PWR), the Vmax is 26.25 V and Imax is 110.48 mA. For the Signal (SIG), Vmax is 13.65 V and Imax is 2.74 mA.\u003c\/p\u003e\n\u003ch3\u003e🛠️ Installation Guide \u0026amp; Key Steps\u003c\/h3\u003e\n\u003cp\u003eThe 135489-04 is an I\/O module with \u003cspan\u003eInternal Barriers\u003c\/span\u003e and \u003cspan\u003eInternal Terminations\u003c\/span\u003e . It mounts at the rear of the 3500 rack, directly behind the \u003cspan\u003e3500\/40M Proximitor Monitor\u003c\/span\u003e . It provides intrinsically safe (IS) isolation for transducers located in hazardous areas .\u003c\/p\u003e\n\u003ch4\u003e1. Hardware Installation\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003cspan\u003eBypass Channels:\u003c\/span\u003e Before inserting the module, place the associated monitor channels in \u003cspan\u003eBypass\u003c\/span\u003e mode to prevent accidental machinery trips.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cspan\u003eSlot Alignment:\u003c\/span\u003e Insert the I\/O module into the full-height slot at the rear of the rack that corresponds exactly to the 3500\/40M monitor module in the front .\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cspan\u003eSeating \u0026amp; Securing:\u003c\/span\u003e Guide the module along the chassis rails until it connects firmly with the backplane connectors. Tighten the two thumb screws on the front panel.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cspan\u003eIS Grounding:\u003c\/span\u003e The 3500 rack \u003cspan\u003emust contain a 3500\/04 IS Earthing Module\u003c\/span\u003e. Ensure that the grounding fingers on the rear of the I\/O module make secure contact with the rack's IS earth bus bar.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e2. Wiring \u0026amp; Physical Separation\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003cspan\u003eColor-Coded Terminals:\u003c\/span\u003e Connect hazardous area transducer field wiring to the \u003cspan\u003eBlue\u003c\/span\u003e terminals. Connect safe area output signals to the \u003cspan\u003eGreen\u003c\/span\u003e terminals.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cspan\u003e50 mm (2 in) Spacing:\u003c\/span\u003e Maintain a minimum physical distance of \u003cspan\u003e50 mm (2 inches)\u003c\/span\u003e between hazardous (intrinsically safe) wiring and non-hazardous (safe area) wiring.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cspan\u003eRouting Path:\u003c\/span\u003e Route hazardous area wiring upward into the upper wiring troughs and safe area wiring downward into the lower wiring troughs to prevent cross-contamination of signals.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e🛒 Procurement Notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eNo Bussed Transducers:\u003c\/strong\u003e Internal barrier I\/O modules \u003cspan\u003edo not support\u003c\/span\u003e bussed transducers (shared power lines). Each transducer must be wired independently.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eEnclosure Depth Requirements: \u003c\/strong\u003eInternal barrier modules are deeper than standard I\/O modules. They \u003cspan\u003ecannot fit into standard 400 mm deep cabinets\u003c\/span\u003e. A minimum cabinet depth of \u003cspan\u003e600 mm\u003c\/span\u003e or a Bulkhead\/Panel-mount housing is required.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eSlot Count Reduction:\u003c\/strong\u003e Installing the mandatory 3500\/04 IS Earthing Module consumes one dedicated I\/O slot. This reduces the maximum number of available monitor slots in a standard 19-inch rack \u003cspan\u003efrom 14 down to 13\u003c\/span\u003e.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eInternal Terminations Only: \u003c\/strong\u003eThis specific model (-04) features internal screw terminals. It \u003cspan\u003ecannot be used\u003c\/span\u003e with External Termination Blocks (ETBs) or pre-fabricated cables.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eTemperature Restrictions: \u003c\/strong\u003eRacks equipped with internal barriers have a narrower operating temperature range of \u003cspan\u003e0°C to +65°C\u003c\/span\u003e (32°F to +150°F), compared to the standard -30°C lower limit. Ensure proper cabinet ventilation.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666863583595,"sku":"135489-04","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-135489-04-i-o-module-with-internal-barriers-and-internal-terminations-pfud1qtzn2t_898c93e6-a81e-4c17-af39-a2ae95a5f4a2.jpg?v=1765449377"},{"product_id":"bently-nevada-135137-01-3500-45-position-i-o-module","title":"Bently Nevada 135137-01 3500\/45 Position I\/O Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 135137-01\u003c\/strong\u003e is a Position I\/O Module with Internal Terminations designed for use with Proximitors, Rotary Position Transducers (RPTs), or DC Linear Variable Differential Transformers (DC LVDTs) within the 3500\/45 Position Monitor system. The \u003cstrong\u003e135137-01\u003c\/strong\u003e attaches to the rear of the 3500 rack to route input signals from proximity probes, RPTs, and DC LVDTs directly to the 3500\/45 main monitor board for continuous signal conditioning, machinery protection, and position parameter processing.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInternal termination connectors for direct transducer wiring\u003c\/li\u003e\n\u003cli\u003eAccepts signal inputs from Proximitors, RPTs, and DC LVDTs\u003c\/li\u003e\n\u003cli\u003eFull-height rear slot installation design in 3500 rack systems\u003c\/li\u003e\n\u003cli\u003eOperating temperature range of -30 degC to +65 degC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAxial (thrust) position monitoring\u003c\/li\u003e\n\u003cli\u003eDifferential expansion measurement\u003c\/li\u003e\n\u003cli\u003eSingle and dual ramp differential expansion\u003c\/li\u003e\n\u003cli\u003eComplementary Input Differential Expansion (CIDE)\u003c\/li\u003e\n\u003cli\u003eCase expansion monitoring\u003c\/li\u003e\n\u003cli\u003eValve position monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003ePart Number\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e135137-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePosition I\/O Module with Internal Terminations for use with Proximitors, RPTs or DC LVDTs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e135145-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePosition I\/O Module with External Terminations for use with Proximitors, RPTs or DC LVDTs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e139554-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC LVDT Position I\/O Module with Internal Terminations for use with AC LVDTs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e139567-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC LVDT Position I\/O Module with External Terminations for use with AC LVDTs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e176449-04\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500\/45 Position Monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical\u003c\/td\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e241.3 mm x 24.4 mm x 99.1 mm (9.50 in x 0.96 in x 3.90 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical\u003c\/td\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.20 kg (0.44 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical\u003c\/td\u003e\n\u003ctd\u003eRack Space Requirements\u003c\/td\u003e\n\u003ctd\u003e1 full-height rear slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e10 kOhm (Proximitor or RPT inputs), 1 MOhm (DC LVDT inputs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003eTransducer Power Supply\u003c\/td\u003e\n\u003ctd\u003e-24 Vdc (Proximitor or RPT), +15 Vdc (DC LVDT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental\u003c\/td\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-30 degC to +65 degC (-22 degF to +150 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental\u003c\/td\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC (-40 degF to +185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental\u003c\/td\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e95% Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the module into one full-height rear slot directly behind the associated 3500\/45 Position Monitor main board.\u003c\/li\u003e\n\u003cli\u003eSecure field transducer wiring to the internal termination blocks using proper shield grounding techniques.\u003c\/li\u003e\n\u003cli\u003eEnsure operating ambient temperatures around the module do not exceed -30 degC to +65 degC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Directives:\u003c\/strong\u003e European Community Directive 2014\/30\/EU; EN 61000-6-2, EN 61000-6-4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Safety:\u003c\/strong\u003e European Community Directive 2014\/35\/EU; EN 61010-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e European Community Directive 2011\/65\/EU; China RoHS SJ\/T 11364-2024 EFUP 15 years\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaritime:\u003c\/strong\u003e DNV GL rules; ABS Rules (Steel Vessels Rules, Offshore Units and Structures)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area Approvals:\u003c\/strong\u003e cNRTLus Class I, Zone 2 \/ Class I, Division 2, Groups A, B, C, D T4; ATEX\/IECEx II 3 G Ex nA nC ic IIC T4 Gc \/ Ex ec nC ic IIC T4 Gc\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666863616363,"sku":"135137-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-135137-01-position-i-o-module-with-internal-terminations-vf2us0fa5l1_f8077595-c1e7-4dea-afb1-d3e94a83fd76.jpg?v=1765449380"},{"product_id":"bently-nevada-3500-20-02-01-00-135031-01-rack-interface-i-o-module","title":"Bently Nevada 3500\/20-02-01-00 135031-01 Rack Interface I\/O Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 3500\/20-02-01-00 135031-01\u003c\/strong\u003e is a specialized rear-facing interface component that serves as the essential input\/output hub for the \u003cstrong\u003e3500 Series Machinery Protection System\u003c\/strong\u003e. This hardware combination pairs the \u003cstrong\u003e3500\/20\u003c\/strong\u003e Rack Interface Module (RIM) structure with the \u003cstrong\u003e135031-01\u003c\/strong\u003e backplane interface board, incorporating dual RS422\/RS485 serial communication ports and a dedicated RS232 configuration port. The assembly processes proprietary configuration protocols and machinery status data, enabling direct connectivity between monitoring racks, configuration software utilities, and plant host control networks. Beyond digital serial communications, the hardware integrates built-in \u003cstrong\u003esystem contacts\u003c\/strong\u003e including specialized hardware lines for remote rack resetting and a dedicated \u003cstrong\u003eNot-OK Relay\u003c\/strong\u003e configuration to transmit system status faults directly to supervisory automation systems without interrupting the critical machinery protection monitoring path.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eComplete integrated communication assembly combining the \u003cstrong\u003e3500\/20-02-01-00\u003c\/strong\u003e ordering configuration and the \u003cstrong\u003e135031-01\u003c\/strong\u003e serial interface board.\u003c\/li\u003e\n\u003cli\u003eDual independent serial ports configurable for RS422 or RS485 communication protocols via backplane hardware selection.\u003c\/li\u003e\n\u003cli\u003eDedicated front-panel and rear-board RS232 connections optimized for field diagnostics and rack configuration tools.\u003c\/li\u003e\n\u003cli\u003eOnboard dedicated hardware \u003cstrong\u003esystem contacts\u003c\/strong\u003e supporting remote Rack Reset commands and external Configuration Lock mechanisms.\u003c\/li\u003e\n\u003cli\u003eIntegrated \u003cstrong\u003eNot-OK Relay\u003c\/strong\u003e providing an automated hardware contact trip if a fault is detected in any monitoring channel.\u003c\/li\u003e\n\u003cli\u003eNon-interfering communication architecture ensuring data polling and configurations do not impact the baseline machinery protection path.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSerial Modbus or proprietary communication linking vibration monitoring racks to industrial PLCs and Distributed Control Systems (\u003cstrong\u003eDCS\u003c\/strong\u003e).\u003c\/li\u003e\n\u003cli\u003eRemote plant machinery asset tracking and centralized multi-rack configuration management.\u003c\/li\u003e\n\u003cli\u003eIntegrating hardware-level rack fault warnings with safety interlock loops via the system contact relays.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOrdering Code \/ Part Number\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/20-AXX-BXX-CXX\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRack Interface Module complete ordering matrix.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA: 02\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRack Interface I\/O Module with RS422\/RS485 Internal Terminations.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB: 01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCommunication Option: RS232\/RS422\/RS485 Serial Communications.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eC: 00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAgency Approval Option: None.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e135031-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eI\/O Board Component:\u003c\/strong\u003e Rack Interface I\/O Module with RS422\/RS485 Internal Terminations.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e125744-02\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eMain Component:\u003c\/strong\u003e Rack Interface Module (Front-facing card).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter Category\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCombined Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/20-02-01-00 135031-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRack Interface I\/O Module with Serial Communications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.3 Watts typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSerial Communication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS422 and RS485 (Switch-selectable protocols)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConfiguration Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS232 protocol via 9-pin D-sub connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNot-OK Relay Contact\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 A @ 24 Vdc or 120 Vac, epoxy-sealed SPDT design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Input Contacts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRack Reset, Configuration Lock, and Trip Multiply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 degC to +65 degC (-22 degF to +150 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC (-40 degF to +185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMain Card Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241.3 mm x 24.4 mm x 241.8 mm (9.50 in x 0.96 in x 9.52 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eI\/O Card Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241.3 mm x 24.4 mm x 99.1 mm (9.50 in x 0.96 in x 3.90 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMain Module Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.91 kg (2.0 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eI\/O Module Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.45 kg (1.0 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cp\u003eThe terminal interfaces and visual indicators on the \u003cstrong\u003e3500\/20-02-01-00 135031-01\u003c\/strong\u003e layout provide specific signaling and connection tracking:\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003ePort \/ Terminal Block\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction \/ Assignment\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOK LED\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront panel indicator; remains lit green when the interface processes software tasks without internal fault.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTX\/RX LED\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront panel indicator; flashes to show active digital data transmission over the backplane bus.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCONFIG Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront-facing 9-pin RS232 port dedicated to connecting a field PC running configuration software.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHOST Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRear \u003cstrong\u003e135031-01\u003c\/strong\u003e 9-pin RS232 connection utilized for host data polling interfaces.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRACK RS422 \/ RS485\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInternal termination screw blocks for routing long-distance serial networks to the plant control room.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSYSTEM CONTACTS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRear terminal block pins assigning lines for Rack Reset, Configuration Lock, and Not-OK relay outputs.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlot Allocation:\u003c\/strong\u003e Mount the companion front card exclusively into Slot 1 of the chassis frame, which is located directly adjacent to the power supply bay, and attach the \u003cstrong\u003e135031-01\u003c\/strong\u003e interface module into the corresponding rear slot position.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocol Selection:\u003c\/strong\u003e Set the internal hardware termination switches on the \u003cstrong\u003e135031-01\u003c\/strong\u003e circuit card to properly match the designated plant RS422 or RS485 balanced transmission network parameters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Termination:\u003c\/strong\u003e For end-of-line installations on a long-distance multi-drop serial bus, enable the onboard line-termination resistors to prevent signal reflections and data loss.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSecurity Wiring:\u003c\/strong\u003e Connect a physical external keyswitch to the Configuration Lock contacts on the rear terminal block to protect the rack configuration from unauthorized or accidental software changes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding Protocol:\u003c\/strong\u003e Ensure the serial data cable shields are securely terminated at the chassis ground block to prevent electromagnetic interference from distorting high-speed communication bursts.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Directives:\u003c\/strong\u003e European Community Directive 2014\/30\/EU.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Standards:\u003c\/strong\u003e EN 61000-6-2 (Industrial Immunity), EN 61000-6-4 (Industrial Emissions).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Safety:\u003c\/strong\u003e Low Voltage Directive 2014\/35\/EU, EN 61010-1 Standard.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Directive:\u003c\/strong\u003e 2011\/65\/EU European Compliance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNorth American Approvals:\u003c\/strong\u003e cNRTLus Class I, Division 2, Groups A, B, C, and D (T4 @ Ta = -20 degC to +65 degC).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX\/IECEx Approvals:\u003c\/strong\u003e II 3 G Ex nA nC ic IIC T4 Gc \/ Ex ec nC ic IIC T4 Gc.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the functional connection between the 3500\/20-02-01-00 code and the 135031-01 part number?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003e3500\/20-02-01-00\u003c\/strong\u003e represents the exact multi-digit factory ordering structure which mandates serial communications and specific internal terminal layouts, while the \u003cstrong\u003e135031-01\u003c\/strong\u003e is the exact manufacturer manufacturing part number assigned to the physical rear I\/O circuit board delivered inside that combination.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I toggle the rear serial port network options between RS422 and RS485 protocols?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe selection between protocols requires adjusting the physical positioning of hardware micro-switches located directly on the \u003cstrong\u003e135031-01\u003c\/strong\u003e rear card assembly prior to powering the device.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWill an absolute failure of this interface module interrupt the machinery protection trip loops?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, the module functions outside the primary, direct hardware monitoring path, meaning a complete loss of communication or power to this card has zero impact on the baseline asset trip loops or monitoring execution.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if a module fault occurs anywhere across the 3500 rack chassis?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe integrated Not-OK Relay contact loop hosted on the backplane block immediately shifts its hardware switch state, providing an instant hardwired system alert to an external PLC or alarm panel.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666864075115,"sku":"135031-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-20-02-01-00-135031-01-rack-interface-i-o-module-jytao5rpj3n_3f8ea88d-edeb-4043-ac6e-7df04fa03052.jpg?v=1765449387"},{"product_id":"bently-nevada-146031-01-3500-22m-10base-t-100base-tx-i-o-module","title":"Bently Nevada 146031-01 3500\/22M 10Base-T\/100Base-TX I\/O Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada \u003cstrong\u003e146031-01\u003c\/strong\u003e is a 10Base-T\/100Base-TX I\/O module designed for interfacing the 3500\/22M Transient Data Interface (TDI) module to host software via Ethernet in machinery protection and condition monitoring systems. It resides in a full-height rear slot of a 3500 rack and incorporates an RJ-45 copper Ethernet interface conforming to IEEE 802.3 standards to support BN Host Protocol and BN TDI Protocol over TCP\/IP. The module provides external physical interfaces for system contacts including Trip Multiply, Alarm Inhibit, and Rack Reset inputs, as well as an onboard OK Relay and a 2-pin Signal Common external grounding terminal.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIntegrates an autosensing 10Base-T\/100Base-TX copper Ethernet RJ-45 connection.\u003c\/li\u003e\n\u003cli\u003eFeatures an onboard OK Relay for rack status annunciation.\u003c\/li\u003e\n\u003cli\u003eProvides system contact input terminals for Trip Multiply, Alarm Inhibit, and Rack Reset.\u003c\/li\u003e\n\u003cli\u003eIncludes a 2-pin Signal Common terminal for connecting instrument ground.\u003c\/li\u003e\n\u003cli\u003eFeatures integrated arc suppressors for relay contact protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eReal-time steady-state and transient dynamic data collection in 3500 machinery protection systems.\u003c\/li\u003e\n\u003cli\u003eEthernet communication interface between 3500 racks and System 1 Condition Monitoring and Diagnostic Software.\u003c\/li\u003e\n\u003cli\u003eRemote system configuration via 3500 System Configuration Software over TCP\/IP networks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003ePart Number \/ Option\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/22-AA-BB-CC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTransient Data Interface Module and I\/O\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOption B: 01\u003c\/td\u003e\n\u003ctd\u003e10Base-T\/100Base-TX Ethernet I\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOption B: 02\u003c\/td\u003e\n\u003ctd\u003e100Base-FX (Fiber Optic) Ethernet I\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOption B: 03\u003c\/td\u003e\n\u003ctd\u003e10Base-T\/100Base-TX Ethernet I\/O Module with gold-plated OK Relay contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOption B: 04\u003c\/td\u003e\n\u003ctd\u003e100Base-FX (Fiber Optic) Ethernet I\/O Module with gold-plated OK Relay contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpares\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e146031-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e10Base-T\/100Base-TX I\/O Module\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e146031-02\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e100Base-FX (Fiber Optic) I\/O Module\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e146031-03\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e100Base-T\/100Base-TX I\/O Module GLD Plated\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e146031-04\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e100Base-FX (Fiber Optic) I\/O Module GLD Plated\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable style=\"width: 100%;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 23.6287%;\"\u003eCategory\u003c\/th\u003e\n\u003cth style=\"width: 24.8945%;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"width: 50.6329%;\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.6287%;\"\u003e\u003cstrong\u003eGeneral\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 24.8945%;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"width: 50.6329%;\"\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.6287%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 24.8945%;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"width: 50.6329%;\"\u003e146031-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.6287%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 24.8945%;\"\u003eCompatible Module\u003c\/td\u003e\n\u003ctd style=\"width: 50.6329%;\"\u003e3500\/22M Transient Data Interface (TDI) Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.6287%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 24.8945%;\"\u003eRack Space Requirements\u003c\/td\u003e\n\u003ctd style=\"width: 50.6329%;\"\u003e1 full-height rear slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.6287%;\"\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 24.8945%;\"\u003eEthernet Type\u003c\/td\u003e\n\u003ctd style=\"width: 50.6329%;\"\u003e10Base-T \/ 100Base-TX, autosensing (Conforms to IEEE802.3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.6287%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 24.8945%;\"\u003eConnector Type\u003c\/td\u003e\n\u003ctd style=\"width: 50.6329%;\"\u003eRJ-45 (telephone jack style)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.6287%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 24.8945%;\"\u003eProtocols Supported\u003c\/td\u003e\n\u003ctd style=\"width: 50.6329%;\"\u003eBN Host Protocol and BN TDI Protocol using Ethernet TCP\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.6287%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 24.8945%;\"\u003eMaximum Cable Length\u003c\/td\u003e\n\u003ctd style=\"width: 50.6329%;\"\u003e100 meters (328 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.6287%;\"\u003e\u003cstrong\u003eOK Relay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 24.8945%;\"\u003eStandard Contact Rating\u003c\/td\u003e\n\u003ctd style=\"width: 50.6329%;\"\u003e5 A @ 24 Vdc \/ 120 Vac, 120 Watts \/ 600 VA Switched Power (maximum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.6287%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 24.8945%;\"\u003eOperation\u003c\/td\u003e\n\u003ctd style=\"width: 50.6329%;\"\u003eNormally Energized\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.6287%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 24.8945%;\"\u003eContact Protection\u003c\/td\u003e\n\u003ctd style=\"width: 50.6329%;\"\u003eArc suppressors provided\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.6287%;\"\u003e\u003cstrong\u003eSystem Contacts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 24.8945%;\"\u003eTrip Multiply Contact\u003c\/td\u003e\n\u003ctd style=\"width: 50.6329%;\"\u003e\u0026lt;1 mAdc, Dry Contact to Common\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.6287%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 24.8945%;\"\u003eAlarm Inhibit Contact\u003c\/td\u003e\n\u003ctd style=\"width: 50.6329%;\"\u003e\u0026lt;1 mAdc, Dry Contact to Common\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.6287%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 24.8945%;\"\u003eRack Reset Contact\u003c\/td\u003e\n\u003ctd style=\"width: 50.6329%;\"\u003e\u0026lt;1 mAdc, Dry Contact to Common\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.6287%;\"\u003e\u003cstrong\u003eEnvironmental\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 24.8945%;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"width: 50.6329%;\"\u003e-30 degC to +65 degC (-22 degF to +149 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.6287%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 24.8945%;\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd style=\"width: 50.6329%;\"\u003e-40 degC to +85 degC (-40 degF to +185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.6287%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 24.8945%;\"\u003eHumidity\u003c\/td\u003e\n\u003ctd style=\"width: 50.6329%;\"\u003e95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.6287%;\"\u003e\u003cstrong\u003eMechanical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 24.8945%;\"\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd style=\"width: 50.6329%;\"\u003e241.3 mm x 24.4 mm x 99.1 mm (9.50 in x 0.96 in x 3.90 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.6287%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 24.8945%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"width: 50.6329%;\"\u003e0.20 kg (0.44 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eConnector Pin \/ Interface\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOK RELAY\u003c\/td\u003e\n\u003ctd\u003eInternal termination header for OK Relay contacts (Selectable OPEN or CLOSED contact)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOM \/ Signal Common\u003c\/td\u003e\n\u003ctd\u003e2-pin connector for connecting Signal Common to Instrument Ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRJ-45 Port\u003c\/td\u003e\n\u003ctd\u003eEthernet 10Base-T\/100Base-TX port for configuration and data collection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSYSTEM CONTACTS (TM)\u003c\/td\u003e\n\u003ctd\u003eTrip Multiply input terminal (Dry Contact to Common)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSYSTEM CONTACTS (INHB)\u003c\/td\u003e\n\u003ctd\u003eAlarm Inhibit input terminal (Dry Contact to Common)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSYSTEM CONTACTS (RST)\u003c\/td\u003e\n\u003ctd\u003eRack Reset input terminal (Dry Contact to Common)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUpgrade Sequence Advisory:\u003c\/strong\u003e When upgrading a 3500 rack from a 3500\/20 RIM to a 3500\/22 TDI, remove the existing RIM and RIM I\/O module before inserting the new TDI I\/O module and TDI front module to prevent damage to the TDI.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlot Allocation:\u003c\/strong\u003e Install the module in the 1 full-height rear slot directly behind the 3500\/22M TDI module in Slot 1.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding Connection:\u003c\/strong\u003e Use the 2-pin Signal Common connector to attach Signal Common to a single-point Instrument Ground for the rack.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Input Module (PIM) Adjustment:\u003c\/strong\u003e When connecting Signal Common to Instrument Ground via the I\/O module, slide the selector switch on the side of the Power Input Module (PIM) in the direction of the arrow marked \"HP\" to isolate Signal Common from chassis ground.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC:\u003c\/strong\u003e European Community Directive 2014\/30\/EU; EN 61000-6-2, EN 61000-6-4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Safety:\u003c\/strong\u003e European Community Directive 2014\/35\/EU; EN 61010-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e European Community Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFCC:\u003c\/strong\u003e Complies with part 15 of the FCC Rules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaritime:\u003c\/strong\u003e DNV GL rules for classification; ABS Rules for Condition of Classification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area Approvals:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ecNRTLus:\u003c\/strong\u003e Class I, Zone 2: AEx\/Ex nA nC ic IIC T4 Gc; Class I, Zone 2: AEx\/Ex ec nC ic IIC T4 Gc; Class I, Division 2, Groups A, B, C, and D (T4 @ Ta = -20 degC to +65 degC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX\/IECEx:\u003c\/strong\u003e Ex II 3 G, Ex nA nC ic IIC T4 Gc, Ex ec nC ic IIC T4 Gc (T4 @ Ta = -20 degC to +65 degC)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666865516907,"sku":"146031-01 3500\/22M","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-146031-01-transient-module-5waarynlxax_ca541a1e-7639-4df0-ae31-6efbdad78842.jpg?v=1765449431"},{"product_id":"bently-nevada-3500-33-03-00-149992-03-low-current-16-channel-relay-output-module","title":"Bently Nevada 3500\/33-03-00 149992-03 Low Current 16-Channel Relay Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 3500\/33-03-00 149992-03\u003c\/strong\u003e is a full-height 16-channel relay output module designed to provide advanced programmable safety voting and alarm drive logic for the \u003cstrong\u003e3500 Series Machinery Protection System\u003c\/strong\u003e. As a factory-configured low-current assembly, the \u003cstrong\u003e3500\/33-03-00 149992-03\u003c\/strong\u003e features specialized gold-plated relay contacts engineered specifically to ensure maximum contact integrity and prevent surface oxidation in low-power signaling applications. Each of its sixteen independent outputs possesses dedicated \u003cstrong\u003eAlarm Drive Logic\u003c\/strong\u003e, allowing operators to program complex combinational AND\/OR logic gates utilizing alert, danger, or Not-OK statuses gathered from any vibration, position, or temperature monitor module across the rack. This combined hardware and software solution serves as a highly reliable, hardware-voted emergency trip bridge between critical plant rotating assets and external Distributed Control Systems (\u003cstrong\u003eDCS\u003c\/strong\u003e), programmable logic controllers (\u003cstrong\u003ePLC\u003c\/strong\u003e), or Emergency Shutdown Systems (\u003cstrong\u003eESD\u003c\/strong\u003e).\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eComplete integrated 16-channel safety relay assembly consisting of the \u003cstrong\u003e3500\/33-03-00\u003c\/strong\u003e system code and the \u003cstrong\u003e149992-03\u003c\/strong\u003e gold-contact main processor board.\u003c\/li\u003e\n\u003cli\u003eOnboard gold-plated contacts optimized for highly stable low-voltage and low-current circuit switching.\u003c\/li\u003e\n\u003cli\u003eHighly flexible \u003cstrong\u003eAlarm Drive Logic\u003c\/strong\u003e matrix supporting customized voting schemes based on multi-channel alert and danger variables.\u003c\/li\u003e\n\u003cli\u003eLive-swap hot-pluggable architecture enabling seamless physical card replacement without disturbing adjacent online machinery protection loops.\u003c\/li\u003e\n\u003cli\u003eIndividual hardware switch assignments on the circuit board allowing independent Normally Energized (\u003cstrong\u003eNE\u003c\/strong\u003e) or Normally De-energized (\u003cstrong\u003eNDE\u003c\/strong\u003e) configuration per relay.\u003c\/li\u003e\n\u003cli\u003eClear front-panel LED diagnostics providing real-time visual assessment of module health (OK), backplane communication bus activity (TX\/RX), and individual channel alarm states.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLow-current alarm link interfaces connecting heavy rotating machinery protection racks to industrial PLCs and safety controllers.\u003c\/li\u003e\n\u003cli\u003eDistributed logic voting and automated emergency shutdown mapping for high-criticality steam turbines, gas turbines, and compressors.\u003c\/li\u003e\n\u003cli\u003eMulti-point protective trip signaling inside demanding petrochemical facilities, oil refineries, and power generation stations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOrdering Code \/ Component Part Number\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/33-03-00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16-Channel Relay Module complete assembly with Low Current Relays, No Agency Approvals.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA: 03\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Current Relay Module option (utilizes Output Module with Gold Contacts).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB: 00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAgency Approval Option: None.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e149992-03\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eMain Board Component:\u003c\/strong\u003e Low Current 16-Channel Relay Main Module with Gold-Plated Contacts.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter Category\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCombined Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/33-03-00 149992-03\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16-Channel Relay Module (Low Current Gold Variant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.8 Watts typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelay Contact Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle-pole, double-throw (SPDT) \/ Gold-plated contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Contact Load\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 V, 1 mA minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Contact Load\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 Vdc at 2 A resistive \/ 48 Vdc at 0.2 A resistive \/ 125 Vdc at 0.1 A resistive \/ 250 Vac at 2 A resistive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContact Operation Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOnboard switch-selectable for Normally De-energized (NDE) or Normally Energized (NE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 degC to +65 degC (-22 degF to +150 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC (-40 degF to +185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMain Card Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241.3 mm x 24.4 mm x 241.8 mm (9.50 in x 0.96 in x 9.52 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eI\/O Card Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241.3 mm x 24.4 mm x 99.1 mm (9.50 in x 0.96 in x 3.90 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMain Module Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.82 kg (1.8 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eI\/O Module Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.41 kg (0.9 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cp\u003eThe diagnostic readouts on the front and the physical terminations on the rear facilitate distinct interface tracking:\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eComponent Identifier\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunctional Description \/ Assignment\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOK LED\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront panel health light; remains solid green when internal software algorithms process normally.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTX\/RX LED\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront panel communication light; flashes rapidly to indicate active digital backplane traffic.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCHALRM LEDs (1 - 16)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChannel status lights; independent LEDs illuminate directly to show when a specific relay channel is tripped.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRear Terminal Block Contacts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eI\/O backplane connection pins grouping Common (COM), Normally Open (NO), and Normally Closed (NC) lines.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelay Mode Toggles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePhysical multi-position dual-throw onboard switches assigning individual channel states to NDE or NE.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack Positioning:\u003c\/strong\u003e Slide the complete \u003cstrong\u003e3500\/33-03-00 149992-03\u003c\/strong\u003e module assembly into any available full-height slot located strictly to the right of the Transient Data Interface (\u003cstrong\u003eTDI\u003c\/strong\u003e) module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRear Alignment:\u003c\/strong\u003e Secure the corresponding 16-channel internal termination input\/output module (such as 149986-01) into the matching rear slot directly behind the main card.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOnboard Switch Configuration:\u003c\/strong\u003e Adjust the internal physical toggle switches to determine the required Normally Energized or Normally De-energized status for each channel before sliding the board into the live slot.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoop Voltage Verification:\u003c\/strong\u003e Confirm that the downstream instrumentation loops comply strictly with low-voltage and low-current constraints; introducing heavy inductive or high-power loads will destroy the gold-plated contact surfaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLogic Deployment:\u003c\/strong\u003e Open the system rack software suite to map and download the intended AND\/OR safety voting matrix into the module non-volatile memory prior to system testing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Directives:\u003c\/strong\u003e European Community Directive 2014\/30\/EU (EMC Directive).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Standards:\u003c\/strong\u003e EN 61000-6-2 (Industrial Immunity), EN 61000-6-4 (Industrial Emissions).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Safety:\u003c\/strong\u003e Low Voltage Directive 2014\/35\/EU, EN 61010-1 Standard.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Directive:\u003c\/strong\u003e 2011\/65\/EU European Compliance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area Approvals:\u003c\/strong\u003e cNRTLus Class I, Zone 2: AEx\/Ex nA nC ic IIC T4 Gc \/ Class I, Division 2, Groups A, B, C, and D (T4 @ Ta = -20 degC to +65 degC).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX\/IECEx Approvals:\u003c\/strong\u003e II 3 G Ex nA nC ic IIC T4 Gc \/ Ex ec nC ic IIC T4 Gc.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the functional relationship between the 3500\/33-03-00 code and the 149992-03 part number?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003e3500\/33-03-00\u003c\/strong\u003e represents the complete factory ordering model number specifying a 16-channel relay system configured for low-current applications, while the \u003cstrong\u003e149992-03\u003c\/strong\u003e is the exact manufacturer part number printed on the physical low-current main processor board included in that specific combination.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is gold plating critical for the contacts on this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eGold plating is vital for low-current circuitry (down to 1 V, 1 mA) because standard silver contacts develop surface oxidation layers over time under low electrical loads, whereas gold resists tarnish to guarantee a clean connection path.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I perform a hot-swap on this module while machinery monitoring is actively running?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the unit features a fully hot-swappable architecture, allowing maintenance teams to remove or insert the card into the slot without disconnecting power or causing signal drops on adjacent monitor channels.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes a single order of this product supply both the front processor and the rear terminal board?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen purchased as a complete surplus or spare assembly assembly under these factory specifications, it typically denotes the main card; ensure you verify whether your specific system panel requires the matching 149986-01 rear internal termination block as well.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666865549675,"sku":"3500\/33-03-00 149992-03","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-33-03-00-149992-03-spare-16-channel-low-current-relay-output-module-mybdn1u1yaf_20bc0d4c-1b25-4073-ac9e-559a8b4766c0.jpg?v=1765449433"},{"product_id":"bently-nevada-3500-61-01-01-133835-02-temperature-monitor-isolated-i-o-module","title":"Bently Nevada 3500\/61-01-01 133835-02 Temperature Monitor Isolated I\/O Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/61-01-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e133835-02\u003c\/strong\u003e) is a high-performance Temperature Monitor Isolated Input\/Output (I\/O) Module featuring internal terminations. Designed for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMachinery Protection System, this module provides continuous tracking of machinery temperature variables to protect critical assets such as turbines, compressors, and large pumps from thermal damage.\u003c\/p\u003e\n\u003cp\u003eThis specific isolated configuration is engineered to eliminate ground loop interference, ensuring reliable data flow and preventing false trips in demanding environments like petrochemical refineries and power plants. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e133835-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the specific hardware component for isolated I\/O with internal termination resistors, facilitating direct thermocouple readings to the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ebackplane.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e3500\/61-01-01\u003c\/strong\u003e (\u003cstrong\u003e133835-02\u003c\/strong\u003e)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada (Baker Hughes)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIsolated Thermocouple I\/O Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Signal Types\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIsolated Thermocouples (Type E, J, K, T)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eInternal Terminations\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.0 W maximum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e500 VDC galvanic isolation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-30 to 65 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e241.3 mm x 24.4 mm x 103.1 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.82 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eAccurate identification of the model suffix is required to ensure compliance with hazardous area certifications and hardware compatibility.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/61-01-01\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e3500\/61\u003c\/strong\u003e: Temperature Monitor Series Module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e01\u003c\/strong\u003e: Isolated Thermocouple I\/O Module with Internal Terminations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e01\u003c\/strong\u003e: Agency Approval (CN, ATEX, and IECEx for Zone 2 and Class I, Division 2).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHardware Part Number\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e133835-02\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003ch3\u003eInstallation Steps\u003c\/h3\u003e\n\u003col class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHardware Inspection\u003c\/strong\u003e: Examine module pins for damage and verify that jumper settings on the monitor card match the intended sensor type.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eI\/O Module Installation (Rear)\u003c\/strong\u003e: Align the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e133835-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith the rear chassis guides of the target slot. Seat the module firmly into the backplane and secure the thumb screws.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMonitor Module Installation (Front)\u003c\/strong\u003e: Insert the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/61\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMonitor card into the front slot directly opposite the I\/O module. Secure with front panel screws.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eField Wiring\u003c\/strong\u003e: Connect sensor leads directly to the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e133835-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eterminal blocks. For Thermocouples (TC), ensure correct polarity of positive and negative extension wires.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e: Utilize the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConfiguration Software via the TDI port to define sensor types and set Alert\/Danger setpoints before downloading to the rack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eTechnical Notes\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInternal Terminations\u003c\/strong\u003e: This design allows field wiring to connect directly to the I\/O module, eliminating the need for external terminal blocks and reducing cabinet space requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSensor Failure Protection\u003c\/strong\u003e: The module features built-in detection for broken wires. A sensor fault triggers a \"Not OK\" status, alerting the DCS while preventing accidental machine trips.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Constraints\u003c\/strong\u003e: This specific configuration (\u003cstrong\u003e-01\u003c\/strong\u003e) is dedicated to isolated thermocouple inputs. It cannot mix RTD and thermocouple signals on the same I\/O block.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat certifications does the -01 approval option provide?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt includes ATEX, IECEx, and CN certifications for use in Zone 2 and Class I, Division 2 hazardous environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require external resistors for termination?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e133835-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ehardware contains internal termination resistors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow is isolation achieved?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module provides 500 VDC galvanic isolation to protect signal integrity from ground loop interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666865779051,"sku":"3500\/61-01-01 133835-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-61-01-01-133835-02-rtd-tc-non-isolated-with-internal-terminations-otr0qowkozy_008e3679-5f87-4675-9c12-e49f7807f590.jpg?v=1765449441"},{"product_id":"bently-nevada-125800-01-3500-25-keyphasor-i-o-module","title":"Bently Nevada 125800-01 3500\/25 Keyphasor I\/O Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 125800-01\u003c\/strong\u003e is an internal termination Keyphasor I\/O module designed for use with the 3500\/25 Enhanced Keyphasor Module within a 3500 Machinery Protection System rack. The \u003cstrong\u003e125800-01\u003c\/strong\u003e receives input signals directly from proximity probes or magnetic pickups and delivers phase and speed timing signals to monitor modules across the rack system. Installed in a full-height rear slot, this non-isolated I\/O module provides direct internal wiring terminal connections and rear buffered Keyphasor signal outputs for machine diagnostics and TSI monitoring applications.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDirect internal termination connections using Euro-style\/screw terminal blocks for transducer field wiring\u003c\/li\u003e\n\u003cli\u003eDual-channel transducer input handling for proximity probe and magnetic pickup signals\u003c\/li\u003e\n\u003cli\u003eRear-panel buffered Keyphasor signal outputs via terminal headers\u003c\/li\u003e\n\u003cli\u003eSeamless integration with 3500\/25 main half-height cards across legacy and current 3500 system racks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMachinery protection systems requiring once-per-turn or multi-event timing reference signals\u003c\/li\u003e\n\u003cli\u003eShaft rotative speed and phase angle (1X vibration amplitude\/phase) tracking\u003c\/li\u003e\n\u003cli\u003eTurbine, compressor, and large rotating equipment condition monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter Category\u003c\/th\u003e\n\u003cth\u003eSpecification Details\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125800-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Signal Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+0.8 V to -21.0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e21.8 kOhm minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpeed\/Frequency Signal Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInput: 1 to 1,200,000 cpm (0.017 to 20 kHz); Output: 1 to 99,999 cpm (0.017 to 1667 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Signal Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.017 to 100 Hz: +\/-1 cpm; 101 to 500 Hz: +\/-8 cpm; 501 to 20 kHz: +\/-1% of cpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer Power Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-24 Vdc, 40 mA maximum per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuffered Output Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e504 Ohm maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSlot Requirement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 full-height rear slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 degC to +65 degC (-22 degF to +150 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC (-40 degF to +185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241.3 mm x 24.4 mm x 103.1 mm (9.50 in x 0.96 in x 4.06 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.46 kg (1.01 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eConnector Pin\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCH 1 - PWR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransducer Power (-24 Vdc) Channel 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCH 1 - COM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransducer Power Common Channel 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCH 1 - KPH\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eKeyphasor Signal Input Channel 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCH 1 - SHLD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransducer Cable Shield Channel 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCH 2 - PWR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransducer Power (-24 Vdc) Channel 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCH 2 - COM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransducer Power Common Channel 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCH 2 - KPH\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eKeyphasor Signal Input Channel 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCH 2 - SHLD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransducer Cable Shield Channel 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBUF 1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuffered Keyphasor Output Channel 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOM (BUF)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuffered Keyphasor Common Channel 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBUF 2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuffered Keyphasor Output Channel 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOM (BUF)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuffered Keyphasor Common Channel 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSHIELD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem Ground\/Shield Connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack Slot Placement:\u003c\/strong\u003e Mount the I\/O module in the full-height rear slot directly behind the corresponding 3500\/25 main half-height module position.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring \u0026amp; Shielding:\u003c\/strong\u003e Connect transducer field wiring to the internal terminal blocks (PWR, COM, KPH, SHLD). Ensure shield wires are properly landed at the assigned SHLD terminals to prevent signal noise.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal Termination Compatibility:\u003c\/strong\u003e Do not attempt to connect External Termination (ET) blocks or cables to this internal termination module.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Directives:\u003c\/strong\u003e European Community Directive 2014\/30\/EU; Standards EN 61000-6-2, EN 61000-6-4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Safety:\u003c\/strong\u003e European Community Directive 2014\/35\/EU; Standard EN 61010-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area (cNRTLus):\u003c\/strong\u003e Class I, Zone 2: AEx\/Ex nA nC ic IIC T4 Gc; Class I, Zone 2: AEx\/Ex ec nC ic IIC T4 Gc; Class I, Division 2, Groups A, B, C, and D (T4 @ Ta = -20 degC to +65 degC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area (ATEX\/IECEx):\u003c\/strong\u003e Ex nA nC ic IIC T4 Gc; Ex ec nC ic IIC T4 Gc (T4 @ Ta = -20 degC to +65 degC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaritime Approvals:\u003c\/strong\u003e DNV GL rules for classification (Ships, offshore units); ABS Rules for Condition of Classification Part 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Compliance:\u003c\/strong\u003e RoHS Directive 2011\/65\/EU; China RoHS SJ\/T 11364-2024\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666866336107,"sku":"125800-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-125800-01-keyphasor-i-o-module-g0u1ored1qb_f6776ea8-729d-4501-8bed-87071ff51568.jpg?v=1765449463"},{"product_id":"bently-nevada-140482-01-3500-42m-prox-velom-i-o-module-with-external-terminations","title":"Bently Nevada 140482-01 3500\/42M Prox\/Velom I\/O Module with External Terminations","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada 140482-01 is a Prox\/Velom I\/O module with external terminations designed for signal interfacing between transducers and the \u003cstrong\u003e3500\/42M Proximitor Seismic Monitor\u003c\/strong\u003e or \u003cstrong\u003e3500\/72M Recip Rod Position Monitor\u003c\/strong\u003e. The module routes input signals from \u003cstrong\u003eProximitor\u003c\/strong\u003e, \u003cstrong\u003eaccelerometer\u003c\/strong\u003e, \u003cstrong\u003eVelomitor\u003c\/strong\u003e, or \u003cstrong\u003eHTVS\u003c\/strong\u003e transducers located in the field through the rear slot of a 3500 system rack directly into the main monitor board. It conditions incoming signals and delivers power supply outputs while maintaining signal integrity for 4-channel vibration and position monitoring operations.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAccepts inputs from Proximitor, accelerometer, Velomitor, or HTVS transducers\u003c\/li\u003e\n\u003cli\u003eExternal termination interface design for off-rack field wiring connection\u003c\/li\u003e\n\u003cli\u003eSupports multi-channel signal routing to the 3500\/42M and 3500\/72M monitor main boards\u003c\/li\u003e\n\u003cli\u003eOccupies 1 full-height rear slot in the 3500 system rack\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMachinery protection and condition monitoring\u003c\/li\u003e\n\u003cli\u003eHydro-turbines, gas turbines, and steam turbines\u003c\/li\u003e\n\u003cli\u003eReciprocating compressor rod position and drop monitoring\u003c\/li\u003e\n\u003cli\u003eIndustrial pumps, fans, and motor assemblies\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003ePart \/ Option\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e140482-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProx\/Velom I\/O Module with External Terminations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e125808-08\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProximitor \/ Velomitor External Termination Block (Euro Style Connectors)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e128015-08\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProximitor \/ Velomitor External Termination Block (Terminal Strip Connectors)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e129525-AAAA-BB\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500 Transducer XDCR signal to External Termination Block Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e00561941\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500\/42M Prox\/Velom I\/O Module 10-pin connector shunt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (a Baker Hughes Company)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e140482-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProx\/Velom I\/O Module with External Terminations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Transducers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProx\/Accel, Velomitor, HTVS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Parameters (Prox\/Accel)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eU = 23.9 V, I = 45.5 mA, P = 1.09 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Parameters (Velomitor)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eU = 23.9 V, I = 45.5 mA, P = 1.09 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRack Space Requirement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 full-height rear slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 degC to +65 degC (-22 degF to +150 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC (-40 degF to +185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95%, noncondensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241.3 mm x 24.4 mm x 99.1 mm (9.50 in x 0.96 in x 3.90 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.20 kg (0.44 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the module into 1 full-height rear slot corresponding to the associated front monitor module in the 3500 rack.\u003c\/li\u003e\n\u003cli\u003eConnect the external termination block to the rear module using the designated 129525 external termination cable.\u003c\/li\u003e\n\u003cli\u003eEnsure proper field wiring connection on the external termination block with supported transducer types.\u003c\/li\u003e\n\u003cli\u003eDo not attempt to use external termination blocks with internal termination I\/O modules.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eStandard \/ Certification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN 61000-6-2, EN 61000-6-4 (Directive 2014\/30\/EU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical Safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN 61010-1 (Directive 2014\/35\/EU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRoHS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDirective 2011\/65\/EU; China RoHS EFUP 15 years (SJ\/T 11364-2024)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHazardous Area (cNRTLus)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass I, Zone 2: AEx\/Ex nA nC ic IIC T4 Gc; Class I, Zone 2: AEx\/Ex ec nC ic IIC T4 Gc; Class I, Division 2, Groups A, B, C, D (T4 @ Ta= -20 degC to +65 degC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHazardous Area (ATEX\/IECEx)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eII 3 G Ex nA nC ic IIC T4 Gc; Ex ec nC ic IIC T4 Gc (T4 @ Ta= -20 degC to +65 degC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaritime\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABS-Marine and Offshore Applications; DNV GL Rules for Classification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666866434411,"sku":"140482-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/140482-01_001_1200x1200_25e9d186-d5ea-4518-9420-73ccde3f9908.png?v=1787376250"},{"product_id":"bently-nevada-82926-01-3300-transducer-input-output-and-recorder-terminal-module","title":"Bently Nevada 82926-01 3300 Transducer Input\/Output and Recorder Terminal Module","description":"\u003cp\u003eThe \u003cstrong\u003e82926-01\u003c\/strong\u003e Transducer Input\/Output and Recorder Terminal Module is a rear-mounting backplane interface engineered for the Bently Nevada 3300\/20 Dual Thrust Position Monitor. This module supports two independent channels of continuous shaft axial position monitoring, processing raw DC gap voltage signals derived from proximity probe transducers to detect deviation relative to calibrated machine clearances. By establishing direct signal routing to the 3300 chassis bus, the hardware enables early warning of thrust bearing failure based on the position of the thrust collar relative to the axial bearing babbitt. The control logic of the associated monitor evaluates these dual-channel inputs against programmable alert and danger setpoints, providing isolated recorder terminal outputs for trend tracking and interfacing with emergency shutdown systems without on-board electro-mechanical relays.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e82926-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300 System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Monitor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300\/20 Dual Thrust Position Monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannel Count\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 Independent channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMonitored Parameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShaft axial position \/ Thrust displacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal Input Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProximity probe transducer signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelay Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo on-board relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApproximate Shipping Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.27 kg (5 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEngineering Notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe module translates the transducer gap voltage into precise axial displacement metrics, measuring how far the shaft has shifted from its calibrated electrical zero point.\u003c\/li\u003e\n\u003cli\u003eTo achieve proper rotor dynamics representation, the external proximity probes must be installed to observe the thrust collar directly rather than an arbitrary shaft shoulder.\u003c\/li\u003e\n\u003cli\u003eBecause the 82926-01 does not include mechanical relays, any active automatic machinery trip functions must be executed via backplane communication to a dedicated 3300 series relay module.\u003c\/li\u003e\n\u003cli\u003eDisconnecting or miswiring the terminal block outputs will register as a transducer fault or an out-of-limit gap voltage error on the front display of the 3300\/20 monitor.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eImplement dedicated shield grounding protocols at the rear terminal strip by landing the proximity probe extension cable shield at the chassis ground terminal and isolating it at the sensor case.\u003c\/li\u003e\n\u003cli\u003eMaintain strict separation between low-voltage transducer input lines and high-voltage AC utility or control wiring to minimize electromagnetic noise injection into the thrust position loop.\u003c\/li\u003e\n\u003cli\u003eEnsure all terminal lug screws are securely torqued during commissioning to prevent drift in the 4-20 mA recorder loops or intermittent sensor faults caused by mechanical vibration.\u003c\/li\u003e\n\u003cli\u003eAlign the module pins perfectly with the 3300 rack backplane before inserting to avoid bending contacts or disrupting cyclic data exchange with adjacent modules.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical \u0026amp; Procurement FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the 82926-01 terminal module feature integrated mechanical relays for machinery interlocks?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No, the 82926-01 is a passive transducer input\/output and recorder terminal module that passes signal states to the 3300 backplane, requiring a separate relay module for physical contact execution.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this terminal module be used to interface with radial vibration or casing velocity monitors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No, this specific part number is designed and mapped exclusively to match the electrical and channel parameters of the 3300\/20 Dual Thrust Position Monitor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the purpose of the recorder terminals on this rear module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The recorder terminals provide dedicated, continuous analog outputs proportional to the measured shaft axial position, allowing for direct connection to external DCS or chart recorders.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666866499947,"sku":"82926-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-82926-01-i-o-and-record-terminals-relay-module-5onmhshp13c_f9312740-5fab-45b3-a3b6-9cfa1c7c35b5.jpg?v=1765449471"},{"product_id":"bently-nevada-136711-02-3500-61-rtd-tc-i-o-module-with-internal-barriers-and-internal-terminations","title":"Bently Nevada 136711-02 3500\/61 RTD\/TC I\/O Module with Internal Barriers and Internal Terminations","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 136711-02\u003c\/strong\u003e is a non-isolated RTD\/TC I\/O module with internal barriers and internal terminations designed for processing temperature transducer inputs within the 3500 Machinery Protection System. Installed in a full-height rear slot directly behind the 3500\/61 Temperature Monitor main module, it accepts input signals from up to six Resistance Temperature Detector (RTD) or Thermocouple (TC) transducers. The \u003cstrong\u003e136711-02\u003c\/strong\u003e channels conditioned signals and +4 to +20 mA proportional recorder outputs through integrated internal barriers to support intrinsically safe machinery monitoring applications in industrial environments.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProvides internal zener barriers and internal termination wiring connectors for six input channels\u003c\/li\u003e\n\u003cli\u003eInterface options configurable for 3-wire RTD, 4-wire RTD, and Thermocouple transducers\u003c\/li\u003e\n\u003cli\u003eIntegrates directly behind the 3500\/61 Temperature Monitor via the 3500 system backplane\u003c\/li\u003e\n\u003cli\u003eRoutes +4 to +20 mA proportional recorder outputs for each individual channel\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBearing temperature monitoring in rotating machinery such as turbines, compressors, and pumps\u003c\/li\u003e\n\u003cli\u003eProcess temperature measurement using RTD and TC transducers in hazardous location areas\u003c\/li\u003e\n\u003cli\u003eMachinery protection and condition monitoring within the 3500 system architecture\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e136711-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Main Module\u003c\/td\u003e\n\u003ctd\u003e3500\/61 Temperature Monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eRTD\/TC Non-Isolated I\/O Module with Internal Barriers and Internal Terminations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003eAccepts 1 to 6 RTD or TC transducer signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003eGreater than 10 Mohm for each lead input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermocouple Types\u003c\/td\u003e\n\u003ctd\u003eType E (-100 degC to +1000 degC), Type J (0 degC to +760 degC), Type K (0 degC to +1370 degC), Type T (-160 degC to +400 degC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTD Types\u003c\/td\u003e\n\u003ctd\u003e100 ohm 3-wire \u0026amp; 4-wire platinum (alpha = 0.00385 or 0.00392), 120 ohm 3-wire \u0026amp; 4-wire nickel, 10 ohm 3-wire \u0026amp; 4-wire copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTD Current Source Value\u003c\/td\u003e\n\u003ctd\u003e925 +-15 uA at 25 degC per transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecorder Outputs\u003c\/td\u003e\n\u003ctd\u003e+4 to +20 mA proportional to monitor full-scale (individual per channel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Compliance (Current Output)\u003c\/td\u003e\n\u003ctd\u003e0 to +12 Vdc range across load (0 to 600 ohm load resistance)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecorder Output Resolution\u003c\/td\u003e\n\u003ctd\u003e0.3662 uA per bit +-0.15% error at room temperature (+-0.4% error over temperature range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 degC to +65 degC (32 degF to +150 degF) when used with Internal Barrier I\/O Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC (-40 degF to +185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Space Requirement\u003c\/td\u003e\n\u003ctd\u003e1 full-height rear slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e241.3 mm x 24.4 mm x 163.1 mm (9.50 in x 0.96 in x 6.42 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.46 kg (1.01 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the I\/O module in a single full-height rear slot positioned directly behind the corresponding 3500\/61 Temperature Monitor module.\u003c\/li\u003e\n\u003cli\u003eSecure wiring connections to the green and blue internal termination connector headers according to transducer type wiring configurations.\u003c\/li\u003e\n\u003cli\u003eEnsure operating ambient temperatures remain within the designated limit of 0 degC to +65 degC when internal barriers are active.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification \/ Standard\u003c\/th\u003e\n\u003cth\u003eStandard \/ Details\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC Directive\u003c\/td\u003e\n\u003ctd\u003e2004\/108\/EC (EN 61000-6-2, EN 55011\/CISPR 11, EN 61000-6-4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow Voltage Directive\u003c\/td\u003e\n\u003ctd\u003e2006\/95\/EC (EN 61010-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNorth American Hazardous Area Approval\u003c\/td\u003e\n\u003ctd\u003eEx nC [ia] IIC: Class I, Div 1; AEx nC [ia] IIC: Class 1, Zone 2\/0 Groups A, B, C, D; T4 @ Ta = -20 degC to +65 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eATEX Approval\u003c\/td\u003e\n\u003ctd\u003eII 3\/(1) G, Ex nC[ia Ga] IIC T4 Gc, T4 @ Ta = -20 degC to +65 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrazil Approval (3500\/61 only)\u003c\/td\u003e\n\u003ctd\u003eBR-Ex nC[nL] IIC T4, T4 @ Ta = -20 degC to +65 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSouth Africa Approval\u003c\/td\u003e\n\u003ctd\u003eEx nCAL [ia] IIC T4, Ex nCAL [L] IIC T4, T4 @ Ta = -20 degC to +65 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666867319147,"sku":"136711-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-136711-02-internal-barriers-ira3aicimyi_32129713-62e8-4d9f-b345-fc759ea1af04.jpg?v=1765449500"},{"product_id":"bently-nevada-128031-01-3500-series-i-o-module-cover","title":"Bently Nevada 128031-01 3500 Series I\/O Module Cover","description":"\u003cp\u003eThe \u003cstrong\u003e128031-01\u003c\/strong\u003e is a full-height rear I\/O module blank cover designed for the Bently Nevada 3500 Series Machinery Monitoring System. The \u003cstrong\u003e128031-01\u003c\/strong\u003e protects unused rear slots on the \u003cstrong\u003e3500\/05\u003c\/strong\u003e system rack from environmental contaminants and maintains proper physical structure across the chassis assembly. It is part of the \u003cstrong\u003e130768-01\u003c\/strong\u003e full-height blank monitor cover kit and requires two screws (\u003cstrong\u003e04310251\u003c\/strong\u003e) for secure mounting.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for full-height rear slots in \u003cstrong\u003e3500\/05\u003c\/strong\u003e system racks\u003c\/li\u003e\n\u003cli\u003ePart of the \u003cstrong\u003e130768-01\u003c\/strong\u003e full-height blank monitor cover kit\u003c\/li\u003e\n\u003cli\u003eFastened using part number \u003cstrong\u003e04310251\u003c\/strong\u003e screws\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProtecting unused rear I\/O slots in Bently Nevada \u003cstrong\u003e3500\/05\u003c\/strong\u003e system racks\u003c\/li\u003e\n\u003cli\u003eDust and debris shielding for open rack positions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003ePart Number\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e128031-01\u003c\/td\u003e\n\u003ctd\u003eI\/O Module Cover (qty 1) Order part 04310251 for screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e04310251\u003c\/td\u003e\n\u003ctd\u003eScrew for I\/O Module Cover (qty 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e130768-01\u003c\/td\u003e\n\u003ctd\u003eFull-height Blank Monitor Cover Kit (Includes 130944-01, 128031-01, and 04310251)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eComponent Type\u003c\/td\u003e\n\u003ctd\u003eFull-Height I\/O Module Blank Cover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible System\u003c\/td\u003e\n\u003ctd\u003e3500\/05 System Rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssociated Kit\u003c\/td\u003e\n\u003ctd\u003e130768-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFastener Requirement\u003c\/td\u003e\n\u003ctd\u003e2x Part 04310251 Screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAlign the \u003cstrong\u003e128031-01\u003c\/strong\u003e cover over the unpopulated rear slot of the \u003cstrong\u003e3500\/05\u003c\/strong\u003e system rack.\u003c\/li\u003e\n\u003cli\u003eSecure the cover to the rack chassis using two \u003cstrong\u003e04310251\u003c\/strong\u003e screws.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666867450219,"sku":"128031-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-128031-01-i-o-module-cover-ok3qf3m20hw_671c7e4d-de00-4620-a56d-7b6f0540b2a8.jpg?v=1765449501"},{"product_id":"bently-nevada-146031-02-3500-22m-100base-fx-fiber-optic-i-o-module","title":"Bently Nevada 146031-02 3500\/22M 100Base-FX (Fiber Optic) I\/O Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 146031-02\u003c\/strong\u003e is a 100Base-FX Fiber Optic Ethernet I\/O Module designed for use with the \u003cstrong\u003e3500\/22M Transient Data Interface Module\u003c\/strong\u003e within the Bently Nevada 3500 Machinery Protection System. Installed in the rear slot of a 3500 rack, the \u003cstrong\u003e146031-02\u003c\/strong\u003e provides full-duplex multimode fiber optic Ethernet communication to interface the rack with System 1 Condition Monitoring and Diagnostic software, 3500 System Configuration software, and 3500 Display software. It includes system contacts for Trip Multiply, Alarm Inhibit, and Rack Reset, an OK Relay contact for rack status annunciation, and a 2-pin terminal for connecting Signal Common to a single-point instrument ground.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProvides 100Base-FX fiber optic Ethernet interface for the 3500\/22M TDI.\u003c\/li\u003e\n\u003cli\u003eUtilizes MT-RJ male connector for multimode fiber optic cabling up to 2000 meters (6560 feet).\u003c\/li\u003e\n\u003cli\u003eSupports BN Host Protocol and BN TDI Protocol over Ethernet TCP\/IP.\u003c\/li\u003e\n\u003cli\u003eIncludes OK Relay output for indicating normal rack operation or fault conditions.\u003c\/li\u003e\n\u003cli\u003eFeatures dry contact system inputs for Trip Multiply, Alarm Inhibit, and Rack Reset.\u003c\/li\u003e\n\u003cli\u003eIncludes a 2-pin Signal Common connector for instrument ground connection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-noise industrial environments requiring electromagnetic immunity via fiber optic communication.\u003c\/li\u003e\n\u003cli\u003eLong-distance machinery protection network links up to 2000 meters between 3500 racks and control rooms.\u003c\/li\u003e\n\u003cli\u003eIntegration with System 1 Condition Monitoring and Diagnostic software and 3500 Configuration software.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e3500\/22-AA-BB-CC\u003c\/td\u003e\n\u003ctd\u003e3500\/22M TDI Module and I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOption B (I\/O Module Type) - 02\u003c\/td\u003e\n\u003ctd\u003e100Base-FX (Fiber Optic) Ethernet I\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOption B (I\/O Module Type) - 04\u003c\/td\u003e\n\u003ctd\u003e100Base-FX (Fiber Optic) Ethernet I\/O Module with gold-plated OK Relay contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpares: 146031-02\u003c\/td\u003e\n\u003ctd\u003e100Base-FX (Fiber Optic) I\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpares: 146031-04\u003c\/td\u003e\n\u003ctd\u003e100Base-FX (Fiber Optic) I\/O Module GLD Plated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e146031-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003e100Base-FX (Fiber Optic) Ethernet I\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eBently Nevada 3500\/22M TDI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eEthernet, 100Base-FX, Fiber Optic, full duplex multimode (IEEE802.3u compliant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtocols Supported\u003c\/td\u003e\n\u003ctd\u003eBN Host Protocol and BN TDI Protocol using Ethernet TCP\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Connection\u003c\/td\u003e\n\u003ctd\u003eMT-RJ Male Fiber Optic connector (requires MT-RJ Female on cabling)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Cable Length\u003c\/td\u003e\n\u003ctd\u003e2000 metres (6560 feet), multimode fiber optic cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard OK Relay Rating\u003c\/td\u003e\n\u003ctd\u003e5 A @ 24 Vdc \/ 120 Vac, 120 Watts \/ 600 VA Switched Power (maximum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Contacts\u003c\/td\u003e\n\u003ctd\u003eTrip Multiply, Alarm Inhibit, Rack Reset (\u0026lt;1 mAdc, Dry Contact to Common)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-30 degC to +65 degC (-22 degF to +149 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC (-40 degF to +185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e241.3 mm x 24.4 mm x 99.1 mm (9.50 in x 0.96 in x 3.90 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.20 kg (0.44 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Space Requirements\u003c\/td\u003e\n\u003ctd\u003e1 full-height rear slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Pin\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMT-RJ Male Connector\u003c\/td\u003e\n\u003ctd\u003e100Base-FX Fiber Optic Ethernet connection for configuration and data collection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOK Relay Terminal\u003c\/td\u003e\n\u003ctd\u003eRelay contact for rack OK status annunciation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Common Terminal\u003c\/td\u003e\n\u003ctd\u003e2-pin connector for connecting Signal Common to single point Instrument Ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Contacts\u003c\/td\u003e\n\u003ctd\u003eContacts for Trip Multiply, Alarm Inhibit, and Rack Reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlot Placement:\u003c\/strong\u003e Install the 146031-02 I\/O module into the full-height rear slot directly behind the 3500\/22M TDI main module in Slot 1 of the 3500 rack.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFiber Optic Cabling:\u003c\/strong\u003e The module features an MT-RJ Male connector. Fiber optic cables must use an MT-RJ Female connector to ensure proper mating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Grounding:\u003c\/strong\u003e When connecting Signal Common to a single-point instrument ground via the 2-pin connector, slide the selector switch on the side of the Power Input Module (PIM) in the direction of the \"HP\" arrow to isolate Signal Common from chassis ground.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUpgrade Sequence Caution:\u003c\/strong\u003e When upgrading a rack from a 3500\/20 RIM to a 3500\/22 TDI, always remove the RIM main module and RIM I\/O module before inserting the new TDI I\/O module and TDI main module to prevent hardware damage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC:\u003c\/strong\u003e European Community Directive 2014\/30\/EU; EN 61000-6-2, EN 61000-6-4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Safety:\u003c\/strong\u003e European Community Directive 2014\/35\/EU; EN 61010-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e European Community Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFCC:\u003c\/strong\u003e Complies with part 15 of the FCC Rules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaritime:\u003c\/strong\u003e DNV GL rules for classification; ABS Rules for Condition of Classification, Part 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area Approvals:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003ecNRTLus: Class I, Zone 2: AEx\/Ex nA nC ic IIC T4 Gc; Class I, Zone 2: AEx\/Ex ec nC ic IIC T4 Gc; Class I, Division 2, Groups A, B, C, and D; T4 @ Ta = -20 degC to +65 degC (-4 degF to +149 degF)\u003c\/li\u003e\n\u003cli\u003eATEX\/IECEx: Ex II 3 G, Ex nA nC ic IIC T4 Gc, Ex ec nC ic IIC T4 Gc, T4 @ Ta = -20 degC to +65 degC (-4 degF to +149 degF)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666867548523,"sku":"146031-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-146031-02-transient-data-interface-module-vxatwz05g2c_9c8ca786-0bbb-4941-8e3a-06aecca2c14c.jpg?v=1765449506"}],"url":"https:\/\/www.plcprotech.com\/it\/collections\/i-o-modules.oembed","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}