{"title":"New arrivals","description":"\u003cp\u003eExplore our newest inventory of high-performance industrial automation hardware. This collection features the latest arrivals in PLC modules, DCS components, and machinery monitoring systems from industry leaders. We have recently updated our stock with genuine spares for\u003ca href=\"https:\/\/www.plcprotech.com\/collections\/abb-s800-i-o\" class=\"ng-star-inserted\" target=\"_blank\"\u003eABB S800 I\/O\u003c\/a\u003e,\u003ca href=\"https:\/\/www.plcprotech.com\/collections\/bently-nevada-3500-system-machinery-protection\" class=\"ng-star-inserted\" target=\"_blank\"\u003eBently Nevada 3500\u003c\/a\u003esensors, and\u003ca href=\"https:\/\/www.plcprotech.com\/collections\/honeywell-experion-pks-c300-series-c\" class=\"ng-star-inserted\" target=\"_blank\"\u003eHoneywell C300\u003c\/a\u003econtrollers. Whether you need urgent replacements for\u003ca href=\"https:\/\/www.plcprotech.com\/collections\/allen-bradley-controllogix\" class=\"ng-star-inserted\" target=\"_blank\"\u003eAllen-Bradley Controllogix\u003c\/a\u003eor\u003ca href=\"https:\/\/www.plcprotech.com\/collections\/ge-boards-turbine-control\" class=\"ng-star-inserted\" target=\"_blank\"\u003eGE Turbine Control\u003c\/a\u003eboards, our new arrivals are verified, 100% genuine, and ready for immediate global dispatch to minimize your facility's downtime.\u003c\/p\u003e","products":[{"product_id":"bently-nevada-285694-02-3500-61e-6-channel-temperature-monitor","title":"Bently Nevada 285694-02 3500\/61E Monitor di temperatura a 6 canali","description":"\u003ch3\u003ePanoramica del prodotto\u003c\/h3\u003e\n\u003cp\u003eIl\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e285694-02 (3500\/61E)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eè un modulo di monitoraggio della temperatura a sei canali ad alta precisione, progettato per il sistema di protezione dei macchinari Bently Nevada 3500 ENCORE. Utilizzato principalmente in turbine a gas per impieghi gravosi, turbine a vapore e compressori di grandi dimensioni nei settori della generazione di energia e del petrolio e gas, questo modulo fornisce una protezione fondamentale per gli avvolgimenti dei motori e le temperature dei cuscinetti. Elaborando continuamente i segnali dei rilevatori di temperatura a resistenza (RTD) e confrontandoli con i setpoint di Avviso e Pericolo programmabili dall'utente, il\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e285694-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003egarantisce il rilevamento delle escursioni termiche prima che si verifichi un guasto meccanico catastrofico. La capacità di integrarsi sia negli aggiornamenti dei rack legacy 3300 sia nei rack dei moderni sistemi ENCORE lo rende una soluzione versatile per ridurre i tempi di fermo dell'impianto e prolungare il ciclo di vita degli asset rotanti.\u003c\/p\u003e\n\u003ch3\u003eConfigurazione tecnica\u003c\/h3\u003e\n\u003cp\u003eIl\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e285694-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eè configurato come monitor RTD non isolato, ottimizzato per il rilevamento termico ad alta densità, in cui sono standard i sensori al platino a 3 o 4 fili.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVersatilità dei sensori:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupporta RTD al platino da 100 Ohm (alpha = 0.00385 o 0.00392), al nichel da 120 Ohm e al rame da 10 Ohm. L'RTD al platino (0.00385) è lo standard industriale mondiale consigliato per la massima precisione.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdattabilità del sistema:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIn modalità \"Aggiornamento rack\", si interfaccia con i moduli I\/O e i relè esistenti della serie 3300. In modalità \"Sistema ENCORE\", utilizza moduli relè programmabili tramite logica per l'attivazione degli allarmi.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrità del segnale:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFornisce una sorgente di corrente dedicata da 913 microampere per trasduttore (alimentazione singola per il cablaggio a 4 fili, doppia per quello a 3 fili) per garantire una misurazione stabile della resistenza anche su cavi di notevole lunghezza.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVisibilità operativa:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eÈ dotato di LED sul pannello frontale per indicare lo stato OK, Avviso, Pericolo e Bypass, fornendo un feedback diagnostico locale immediato al personale addetto alla manutenzione.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifiche tecniche\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttributo\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecifica\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModello\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e285694-02 (3500\/61E)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMarca\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTipo di ingresso\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRTD a 6 canali (rilevatore di temperatura a resistenza)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCompatibilità RTD\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePlatino da 100 Ohm, nichel da 120 Ohm, rame da 10 Ohm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConsumo energetico\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5.6 watt nominali (opzione RTD)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eUscita del registratore\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDa 4 a 20 mA (individuale per ciascun canale)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRisoluzione\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 grado C o 1 grado F\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePrecisione (platino)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e+\/- 1 grado C max (intervallo limitato a 150 gradi C)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTemperatura di esercizio\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDa -20 gradi C a +65 gradi C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eImpedenza di ingresso\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSuperiore a 3 MOhm per ciascun conduttore\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConformità della tensione\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntervallo da 0 a +12 VCC sul carico (da 0 a 600 Ohm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDomande frequenti di ingegneria\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCome gestisce il 3500\/61E le installazioni con \"Aggiornamento rack\" rispetto alle installazioni \"Sistema completo\"?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIn un aggiornamento rack, il 3500\/61E sostituisce il monitor 3300\/30 o 3300\/35 utilizzando l'I\/O e i relè originali del 3300. In un sistema ENCORE completo, utilizza nuovi moduli I\/O per la temperatura ENCORE e un modulo relè programmabile per attivare gli allarmi.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eÈ necessaria la calibrazione sul campo per questo modulo?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. Tutti i parametri di configurazione vengono impostati tramite il software di configurazione del rack 3500. I circuiti interni ad alta precisione del modulo eliminano la necessità di una calibrazione manuale sul campo una volta definiti il tipo e l'intervallo del trasduttore.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQual è l'impatto di un cortocircuito sulle uscite del registratore?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIl funzionamento del monitor non viene assolutamente influenzato dai cortocircuiti sulle uscite del registratore da 4 a 20 mA. Questo design garantisce che un guasto nella linea di segnale DCS\/PLC non comprometta la logica primaria di protezione dei macchinari.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eLinee guida per l'installazione e indicazioni per l'ingegneria sul campo\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePrecisione del cablaggio RTD:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePer le installazioni RTD a 3 fili, assicurarsi che tutti e tre i conduttori abbiano una resistenza quasi identica e siano instradati insieme. Il\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e285694-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eutilizza due sorgenti di corrente per la compensazione a 3 fili; uno squilibrio significativo nella resistenza dei conduttori introdurrà errori nella misurazione della temperatura, che potrebbero causare interventi intempestivi.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConsiderazioni sulle barriere:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eQuando si utilizzano barriere di sicurezza intrinseca esterne, tenere presente che il limite inferiore \"OK\" del sensore è generalmente ristretto a -50 gradi C. Assicurarsi che il software di configurazione 3500 sia regolato per tenere conto della resistenza aggiuntiva delle barriere e mantenere la precisione della misurazione.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGestione della logica dei relè:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIn una configurazione con sistema ENCORE, ricordare che il\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/61E\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003enon dispone di relè integrati. Deve essere associato a un modulo relè 3500. Verificare che lo stato \"Bypass\" del monitor sia correttamente riportato nella logica di interblocco di sicurezza dell'impianto durante la manutenzione, per evitare il funzionamento alla cieca.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBuone pratiche per la schermatura:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePer ridurre al minimo le interferenze elettromagnetiche (EMI) sui segnali RTD di basso livello, utilizzare cavi schermati a doppino intrecciato. Collegare le schermature esclusivamente alla sbarra di terra del rack 3500 per evitare loop di terra che possono causare \"derive\" del segnale o attivazioni irregolari degli stati di Avviso\/Pericolo.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666516668779,"sku":"3500\/61E 285694-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-61e-285694-02-temperature-monitor-f3g3ccfvs2b_d717d800-41d8-4ef7-ba75-cc9da7657211.jpg?v=1765440094"},{"product_id":"bently-nevada-330910-03-09-05-02-05-3300-nsv-proximity-probe","title":"Bently Nevada 330910-03-09-05-02-05 3300 NSv Sonda di prossimità","description":"\u003ch3\u003ePanoramica del prodotto\u003c\/h3\u003e\n\u003cp\u003eIl\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330910-03-09-05-02-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eè un trasduttore di prossimità specializzato 3300 NSv (Narrow Side View) progettato per il monitoraggio ad alta precisione delle vibrazioni e della posizione in ambienti industriali con spazi limitati. Questa sonda filettata M10X1 è lo standard del settore per compressori di processo, riduttori ad alta velocità e turbine a gas aeroderivative, dove lo spazio laterale è ridotto. Grazie allo stampaggio brevettato\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTipLoc\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eper un robusto collegamento tra punta e corpo e al design\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCableLoc\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econ resistenza alla trazione di 220 N, questa sonda offre una resistenza chimica significativamente superiore rispetto ai precedenti modelli 3300 RAM. Il suo campo magnetico ristretto consente una regolazione accurata del gap anche all’interno di alloggiamenti meccanici compatti, riducendo efficacemente le interferenze. Fornendo dati dinamici fondamentali sull’albero al sistema di protezione dei macchinari 3500, il\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330910-03-09-05-02-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esvolge un ruolo cruciale nella prevenzione di guasti catastrofici delle apparecchiature e nell’ottimizzazione dei cicli di manutenzione negli impianti petrolchimici e di generazione elettrica.\u003c\/p\u003e\n\u003ch3\u003eDecodifica del suffisso\u003c\/h3\u003e\n\u003cp\u003eLa sequenza alfanumerica del\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330910-03-09-05-02-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edefinisce i parametri meccanici e di certificazione specifici necessari per l’integrazione presso il sito:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e03 (Lunghezza non filettata):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSezione del corpo non filettata di 30 mm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e09 (Lunghezza complessiva del corpo):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eLunghezza complessiva del corpo di 90 mm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e05 (Lunghezza totale):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eLunghezza totale del cavo di collegamento di 0,5 metri (20 pollici).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02 (Connettore e cavo):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConnettore coassiale miniaturizzato ClickLoc con cavo standard e armatura integrata in acciaio inossidabile.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e05 (Omologazione dell’ente certificatore):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOmologazioni globali multiple, tra cui FCC, ATEX, IECEx e CSA, per l’uso in aree pericolose a sicurezza intrinseca.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifiche tecniche\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCaratteristica\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecifica\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModello\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330910-03-09-05-02-05\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMarca\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTipo di filettatura\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eM10X1 metrico\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLunghezza del corpo\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e90 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLunghezza del cavo di collegamento\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0,5 metri\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTemperatura di esercizio\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eda -52 a +177 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAltitudine massima\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2000 m\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTenuta alla pressione\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eO-ring in Viton (tenuta per pressione differenziale)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResistenza alla trazione\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e220 N (50 lb)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCoppia di montaggio\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e22,6 N-m (200 in-lb) massimo\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTaratura del bersaglio\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAcciaio AISI 4140 (standard)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDomande frequenti sulla protezione delle apparecchiature\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eLa sonda 3300 NSv è intercambiabile con la precedente serie 3300 RAM?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSì. La sonda 3300 NSv e i cavi di prolunga sono compatibili sia meccanicamente sia elettricamente con i precedenti componenti hardware 3300 RAM, consentendo aggiornamenti presso il sito senza interruzioni e con una maggiore resistenza chimica.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQual è il vantaggio della “Narrow Side View” negli spazi ristretti?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eLe sonde standard richiedono un’ampia area libera intorno alla punta per evitare interferenze dovute al “carico laterale” causato dall’alloggiamento della macchina. La serie NSv presenta caratteristiche superiori di visione laterale, consentendo di mantenere l’accuratezza del segnale quando viene regolata in canali stretti o vicino a superfici metalliche adiacenti.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerché l’esposizione prolungata a temperature inferiori a -34 °C è un problema?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSebbene la sonda sia omologata per il funzionamento fino a -52 °C, l’esposizione prolungata a temperature inferiori a -34 °C (-30 °F) può ridurre l’elasticità dell’O-ring interno in Viton, causando potenzialmente un guasto prematuro della tenuta alla pressione di processo.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eLinee guida tecniche per l’installazione e la messa in servizio\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eImpegno della filettatura e coppia:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePer i corpi delle sonde M10X1, l’impegno massimo della filettatura è limitato a 15 mm. Durante l’installazione, la coppia di montaggio non deve superare 22,6 N-m (200 in-lb) sui primi tre filetti, per evitare la deformazione del corpo. Utilizzare un secondo controdado per fissare la regolazione finale del gap e contrastare gli spostamenti causati dalle vibrazioni.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrità del connettore ClickLoc:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAssicurarsi che i connettori ClickLoc in ottone placcato oro siano completamente inseriti e “scattino” in posizione. Ciò previene l’attenuazione del segnale causata dall’allentamento. Negli ambienti con olio per turbine, evitare di utilizzare nastro in silicone sul raccordo tra sonda e cavo di prolunga; utilizzare invece protezioni per connettori specifiche per impedire l’ingresso dell’olio.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTenuta ambientale:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eL’O-ring in Viton garantisce una tenuta alla pressione differenziale tra la punta della sonda e il corpo. Se l’applicazione prevede gas di processo ad alta pressione o sostanze chimiche speciali, verificare la compatibilità chimica con il Viton e valutare una prova di pressione della tenuta dopo l’installazione, qualora richiesta dai protocolli di sicurezza del sito.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVerifica della tensione del gap:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDurante la regolazione del gap, utilizzare un alimentatore da -24 VDC e un carico da 10 kOhm. Assicurarsi che la sonda sia regolata a 1,0 mm (40 mil) rispetto a un bersaglio in acciaio AISI 4140 con diametro di 31 mm o superiore, per ottenere linearità e intercambiabilità ottimali.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666516767083,"sku":"330910-03-09-05-02-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330910-03-09-05-02-05-proximity-transducer-nj1jrvb3gpw_402b4bd6-63db-424e-9dfd-edd5ef5fdc5c.jpg?v=1765440096"},{"product_id":"bently-nevada-330909-00-80-10-02-05-3300-nsv-proximity-probe","title":"Bently Nevada 330909-00-80-10-02-05 3300 NSv Sonda di prossimità","description":"\u003ch3\u003ePanoramica del prodotto\u003c\/h3\u003e\n\u003cp\u003eIl\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330909-00-80-10-02-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eè una sonda di prossimità 3300 NSv ad alta precisione, progettata per la protezione di macchinari critici in ambienti con spazio limitato o chimicamente aggressivi. Questa sonda è specificamente progettata per compressori di processo e pompe centrifughe a piccolo diametro, spesso presenti nelle raffinerie di petrolio e negli impianti di trattamento chimico. Grazie all'elevata resistenza chimica e a un corpo filettato 3\/8-24 UNF con armatura integrata in acciaio inossidabile, il\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330909-00-80-10-02-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoffre una durata superiore rispetto ai sensori della precedente serie 3300 RAM. Utilizza tecnologie brevettate Bently Nevada, tra cui lo stampaggio TipLoc per un robusto collegamento tra punta e corpo e CableLoc per il fissaggio del cavo con elevata resistenza alla trazione. Fornendo misurazioni affidabili dello spostamento a correnti parassite, questo sistema trasduttore è essenziale per monitorare le vibrazioni e la posizione dell'albero, prevenendo efficacemente guasti catastrofici e riducendo al minimo i fermi non programmati dell'impianto.\u003c\/p\u003e\n\u003ch3\u003eDecodifica del suffisso\u003c\/h3\u003e\n\u003cp\u003eLa configurazione alfanumerica del\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330909-00-80-10-02-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edefinisce i parametri meccanici e di certificazione specifici per l'integrazione sul campo:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00 (Lunghezza non filettata):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003elunghezza non filettata di 0,0 pollici; corpo completamente filettato.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e80 (Lunghezza complessiva del corpo):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003elunghezza complessiva del corpo di 8,0 pollici, che offre una portata sufficiente per le penetrazioni in profondità nel corpo della macchina.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e10 (Lunghezza totale):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003elunghezza totale del cavo di 1,0 metro (39 pollici).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02 (Connettore e cavo):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econnettore coassiale miniaturizzato ClickLoc con cavo standard e armatura integrata in acciaio inossidabile per la protezione fisica.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e05 (Approvazione degli enti):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emolteplici approvazioni internazionali, tra cui FCC, ATEX, IECEx e CSA, per l'uso in aree pericolose a sicurezza intrinseca.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifiche tecniche\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttributo\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecifiche\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModello\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330909-00-80-10-02-05\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMarca\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensione della filettatura\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3\/8-24 UNF\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTipo di sonda\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 NSv (Narrow Side View)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLunghezza totale del sistema\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ecavo da 1,0 metro\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTemperatura di esercizio\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eda -52 a +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTenuta alla pressione\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003etenuta interna con O-ring in Viton\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMateriale del bersaglio\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eacciaio AISI 4140 (calibrazione standard)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCampo lineare\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1,5 mm (60 mil) tipico\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResistenza alla trazione\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e220 N (50 lb) mediante design CableLoc\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtezione\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003earmatura in acciaio inossidabile\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDomande frequenti sulla protezione dei macchinari\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eLa sonda 3300 NSv è compatibile con i sistemi 3300 RAM precedenti?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSì, la sonda 3300 NSv e i cavi di prolunga sono meccanicamente ed elettricamente intercambiabili con la precedente serie 3300 RAM. Tuttavia, la serie NSv offre una resistenza chimica significativamente migliore per le applicazioni con gas di processo.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQual è il vantaggio della configurazione \"Narrow Side View\"?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eLa designazione \"NSv\" indica un campo magnetico più concentrato. Ciò consente di installare la sonda in spazi più ristretti, con minori interferenze da parte del metallo circostante (vista laterale), rispetto alle sonde standard della serie 3000, garantendo un segnale di vibrazione più accurato nelle macchine compatte.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerché è importante evitare temperature inferiori a -34 deg C per periodi prolungati?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSebbene la sonda possa funzionare a -52 deg C, l'esposizione prolungata a temperature inferiori a -34 deg C (-30 deg F) può rendere fragile la tenuta interna alla pressione. Ciò può causare un cedimento prematuro della tenuta e una possibile perdita del fluido di processo nell'alloggiamento.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eDirettive di installazione e ingegneria sul campo\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMontaggio e ingaggio della filettatura:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eper il corpo filettato 3\/8-24 UNF, assicurarsi che l'ingaggio massimo della filettatura non superi 0,563 pollici, per evitare il grippaggio meccanico. Utilizzare una chiave dinamometrica calibrata per il serraggio finale del controdado, assicurandosi che la sonda rimanga ferma durante gli eventi ad alta vibrazione.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrità del connettore (ClickLoc):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003etutti i connettori ClickLoc sono in ottone placcato oro. Durante l'installazione, assicurarsi che i connettori scattino in posizione bloccata. Si consiglia vivamente di utilizzare protezioni per connettori o nastro siliconico per impedire l'ingresso di olio per turbine o umidità, che potrebbero creare un ponte sul segnale coassiale e causare lo stato \"Not OK\" sul monitor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGestione dell'armatura:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003el'armatura integrata in acciaio inossidabile protegge il cavo coassiale dall'abrasione meccanica. Tuttavia, mantenere un raggio di curvatura minimo di 25 mm (1,0 pollice) per evitare di danneggiare il conduttore coassiale miniaturizzato interno. Non consentire all'armatura di entrare in contatto diretto con linee ad alta tensione.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVerifica della tensione di gap:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edurante la messa in servizio, impostare il gap della sonda sul valore standard di 1,0 mm (40 mil), che corrisponde a circa -10 VDC sull'uscita di un Proximitor standard quando si utilizza un bersaglio in acciaio AISI 4140. Verificare sempre il materiale del bersaglio prima della regolazione finale del gap, poiché i materiali diversi dal 4140 richiedono una calibrazione specializzata del Proximitor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666516832619,"sku":"330909-00-80-10-02-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330909-00-80-10-02-05-sensor-proximity-probe-cable-via-fedex-pmvvusodgop_86432078-a2ee-4b4e-843c-4170b8ad4747.jpg?v=1765440097"},{"product_id":"bently-nevada-3500-50-133388-02-tachometer-module","title":"Bently Nevada 3500\/50 133388-02 Modulo contagiri","description":"\u003ch3\u003eDescrizione\u003c\/h3\u003e\n\u003cp\u003eIl \u003cstrong\u003e3500\/50\u003c\/strong\u003e, identificato dal numero di parte di ricambio \u003cstrong\u003e133388-02\u003c\/strong\u003e, è un componente hardware a 2 canali progettato per determinare la velocità di rotazione dell'albero, l'accelerazione del rotore o la direzione del rotore all'interno del sistema di protezione delle macchine 3500. Il modulo si interfaccia direttamente con trasduttori di sonde di prossimità grezzi o pickup magnetici passivi per monitorare la dinamica dell'apparecchiatura. Fungendo da livello di interfaccia analitica, confronta continuamente i dati di frequenza acquisiti con i setpoint di allarme programmabili dall'utente, modificando gli stati per attivare gli allarmi di sicurezza automatici quando le soglie vengono superate. Configurabile tramite il software 3500 Rack Configuration, il modulo può fornire segnali Keyphasor condizionati alla rete del backplane, eliminando la necessità di installazioni indipendenti dell'hardware Keyphasor. Lo strumento emette un segnale analogico indipendente da +4 a +20 mA per registratore per ciascun canale di misurazione, fornendo agli strumenti operativi e di registrazione dell'impianto indicatori diagnostici deterministici.\u003c\/p\u003e\n\u003ch3\u003eCaratteristiche\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFunzionalità a due canali indipendenti per il monitoraggio della frequenza multipunto o della direzione di rotazione.\u003c\/li\u003e\n\u003cli\u003eSupporto versatile dei sensori, compatibile sia con sistemi a correnti parassite con sonde di prossimità sia con pickup magnetici passivi.\u003c\/li\u003e\n\u003cli\u003eQuattro opzioni firmware standard per il monitoraggio della velocità, della banda di velocità, della velocità zero, dell'accelerazione e della rotazione inversa.\u003c\/li\u003e\n\u003cli\u003eLogica integrata di mantenimento del picco che acquisisce la velocità massima in avanti, la velocità massima inversa e le rotazioni inverse cumulative.\u003c\/li\u003e\n\u003cli\u003eDistribuzione interna dei segnali nel rack, con trasmissione dei dati di riferimento Keyphasor condizionati ai monitor adiacenti della serie 3500.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplicazioni\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMonitoraggio della velocità dell'albero del rotore e della rotazione di picco di turbine industriali a vapore e a gas.\u003c\/li\u003e\n\u003cli\u003eMonitoraggio dell'accelerazione e interfaccia per l'arresto di emergenza di compressori centrifughi per gas di processo.\u003c\/li\u003e\n\u003cli\u003eValidazione della velocità zero e notifica della rotazione inversa per ventilatori di torri di raffreddamento di grandi dimensioni.\u003c\/li\u003e\n\u003cli\u003eMonitoraggio del rapporto di velocità tra l'albero di ingresso e quello di uscita dei riduttori industriali ad alta potenza.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInformazioni per l'ordine\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCodice opzione\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescrizione\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/50-AXX-BXX\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eModulo tachimetrico\u003c\/strong\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA: tipo di modulo I\/O\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eModulo I\/O con terminazioni interne \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eModulo I\/O con terminazioni esterne \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e03\u003c\/td\u003e\n\u003ctd\u003eModulo I\/O TMR con terminazioni esterne \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e04\u003c\/td\u003e\n\u003ctd\u003eModulo I\/O con barriere interne e terminazioni interne \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB: opzione di approvazione dell'ente\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNessuno \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eCSA\/NRTL\/C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eC: utilizzo del monitor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eMisurazione della velocità \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eRotazione inversa \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRicambi\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e133388-02\u003c\/td\u003e\n\u003ctd\u003eModulo tachimetrico 3500\/50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSpecifiche tecniche\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParametro\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecifica\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduttore\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModello\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500\/50 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumero di parte\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e133388-02 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCanali di ingresso del segnale\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 trasduttori per sonde di prossimità o pickup magnetici \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIntervallo del segnale di tensione d'ingresso\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDa +10,0 V a -24,0 V \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImpedenza d'ingresso standard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 kΩ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImpedenza d'ingresso TMR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 kΩ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImpedenza d’ingresso della barriera interna\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7,15 kΩ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConsumo energetico nominale\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5,8 watt tipici \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUscita proporzionale del registratore\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDa +4 a +20 mA CC \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConformità della tensione del registratore\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDa 0 a +12 Vcc sul carico \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIntervallo di resistenza del carico del registratore\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDa 0 a 600 Ω \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUscita dell’alimentazione del trasduttore\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-24 Vcc, massimo 40 mA per canale \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequenza massima d’ingresso supportata\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 kHz \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIntervallo massimo della velocità a fondo scala\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e99.999 rpm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLimiti di frequenza della sonda di prossimità\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMinimo 0,0167 Hz (1 rpm per 1 evento\/giro) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLimiti di frequenza del sensore magnetico\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMinimo 3,3 Hz \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrecisione RPM (\u003c 100 rpm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEntro ±0,1 rpm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrecisione RPM (da 100 a 10.000 rpm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEntro ±1 rpm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrecisione RPM (\u003e 10.000 rpm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEntro ±0,01% della velocità effettiva dell’albero \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrecisione dell’accelerazione del rotore\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEntro ±20 giri\/min \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmpiezza di attivazione automatica\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMinimo 1 volt picco-picco \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCampo di attivazione manuale\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDa +9,5 Vcc a -23,5 Vcc con un minimo di 500 mV picco-picco \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsteresi di attivazione regolabile\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSelezionabile dall’utente da 0,2 a 2,5 volt \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIntervallo di ritardo dell’allarme 1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDa 1 a 60 secondi con intervalli di 1 secondo \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIntervallo di ritardo dell’allarme 2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDa 1 a 60 secondi con intervalli di 0,1 secondi \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperatura di esercizio (I\/O standard)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDa -30 Celsius a +65 Celsius (da -22 Fahrenheit a +150 Fahrenheit) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperatura di esercizio (I\/O con barriera)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDa 0 Celsius a +65 Celsius (da 32 Fahrenheit a +150 Fahrenheit) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLimiti della temperatura di stoccaggio\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDa -40 Celsius a +85 Celsius (da -40 Fahrenheit a +185 Fahrenheit) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUmidità massima di esercizio\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95% di umidità relativa senza condensa \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePeso del modulo monitor principale\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0,82 kg (1,8 lb) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePeso del modulo I\/O (senza barriera)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0,20 kg (0,44 lb) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePeso del modulo I\/O (con barriera)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0,46 kg (1,01 lb) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensioni del monitor principale\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241,3 mm x 24,4 mm x 241,8 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensioni del modulo I\/O (senza barriera)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241,3 mm x 24,4 mm x 99,1 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensioni del modulo I\/O (con barriera)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241,3 mm x 24,4 mm x 163,1 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRequisiti del rack dello chassis\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 slot anteriore a tutta altezza e 1 slot posteriore a tutta altezza \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnessioni\/Interfacce\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003ePin del morsetto \/ connettore\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunzione\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBNC CH1 (pannello frontale)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUscita coassiale bufferizzata del trasduttore per il canale 1 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBNC CH2 (pannello frontale)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUscita coassiale bufferizzata del trasduttore per il canale 2 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTRASDUTTORI I\/O (CHI)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMorsettiere PWR \/ COM \/ SIG \/ SHLD per l’ingresso del sensore 1 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTRASDUTTORI I\/O (CH2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMorsettiere PWR \/ COM \/ SIG \/ SHLD per l’ingresso del sensore 2 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMorsettiera CONTATTI\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInterblocchi di abilitazione RESET (PRST1 \/ PRST2) e barriera Zener \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBlocco TRASDUTTORI BUFFERIZZATI\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePin di uscita bufferizzati in stile Euro per oscilloscopi esterni \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBlocco USCITE DEL REGISTRATORE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInterfacce dedicate per loop di corrente COM \/ REC1 \/ REC2 \/ SHLD \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eLinee guida per l’installazione\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMessa a terra: terminare esplicitamente le schermature dei cavi dei sensori di campo sui pin SHLD designati dei blocchi di terminazione posteriori per creare un efficace percorso di Faraday contro il rumore elettrico ad alta frequenza.\u003c\/li\u003e\n\u003cli\u003eAllineamento dello slot: inserire il modulo frontale principale in un qualsiasi slot disponibile a tutta altezza, spingendo saldamente lungo le guide di allineamento finché la scheda non si innesta nelle linee di alimentazione del backplane del rack.\u003c\/li\u003e\n\u003cli\u003eEsclusioni dei sensori: non associare gli ingressi dei pickup magnetici alle funzioni di segnalazione della velocità zero o della rotazione inversa, poiché una bassa velocità dell'albero non è in grado di generare segnali con fronti netti per una corretta interpretazione del trigger.\u003c\/li\u003e\n\u003cli\u003eIntegrità della ventilazione: assicurarsi che siano mantenuti i percorsi di spazio libero sia sulla parte anteriore sia nelle aree dell'interfaccia posteriore, per facilitare i flussi di raffreddamento ad aria forzata attraverso lo chassis dello strumento.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConformità e certificazioni\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDirettive per la marcatura CE: EN50081-2, emissioni irradiate e condotte (Classe A); EN50082-2, norma sull'immunità in ambienti industriali.\u003c\/li\u003e\n\u003cli\u003eDirettive sulla bassa tensione: EN 61010-1, requisiti di sicurezza ambientale per apparecchiature elettriche.\u003c\/li\u003e\n\u003cli\u003eCSA \/ NRTL \/ C: certificato per installazioni di Classe I, Divisione 2, Gruppi da A a D, se combinato con moduli di terminazione standard compatibili.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDomande frequenti tecniche e sugli approvvigionamenti\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eÈ possibile che questo strumento controlli autonomamente le valvole di blocco per sovravelocità dei macchinari dell'impianto?\u003c\/strong\u003e R: No, i moduli tachimetrici Bently Nevada non sono progettati come componenti per il controllo autonomo della velocità o la protezione diretta dalla sovravelocità, poiché non dispongono della ridondanza strutturale critica necessaria per le funzioni di arresto dei macchinari.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eD: Qual è la differenza operativa fisica tra il codice prodotto 133388-02 e la designazione della serie 3500\/50?\u003c\/strong\u003e R: 3500\/50 identifica la famiglia progettuale complessiva dei moduli tachimetrici funzionali, mentre il riferimento 133388-02 indica l'identificativo specifico del componente di ricambio a magazzino per l'assieme della scheda frontale.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eD: È necessaria una calibrazione manuale del circuito di uscita analogica al momento dell'installazione?\u003c\/strong\u003e R: No, non sono necessarie procedure di calibrazione sul campo, poiché tutti gli intervalli di ingresso del trasmettitore, le soglie di tensione e i parametri discreti vengono elaborati digitalmente tramite il livello software 3500.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eD: È possibile assegnare in sicurezza un pickup magnetico per verificare il comportamento della rotazione inversa?\u003c\/strong\u003e R: No, i pickup magnetici passivi non riescono a fornire un fronte del segnale distinto o pulito durante i cicli di rotazione lenta o di arresto dell'albero, causando potenzialmente gravi guasti o un rilevamento errato della direzione nel livello logico.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eD: In che modo un improvviso cortocircuito esterno sul circuito del registratore analogico influisce sul rilevamento complessivo della velocità?\u003c\/strong\u003e R: Le operazioni principali di rilevamento della velocità, monitoraggio degli allarmi ed elaborazione sul backplane rimangono completamente inalterate dai guasti di cortocircuito sui circuiti esterni del registratore.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666519552363,"sku":"3500\/50 133388-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-50-133388-02-tachometer-module-fzrkzbolckl_a2fc124d-c18b-438a-9eb8-c8d07efe8699.jpg?v=1765440133"},{"product_id":"bently-nevada-32000-28-05-15-080-03-02-metric-proximity-probe-housing-assembly","title":"Bently Nevada 32000-28-05-15-080-03-02 Gruppo alloggiamento metrico per sonda di prossimità","description":"\u003ch3\u003ePanoramica commerciale\u003c\/h3\u003e\n\u003cp\u003eIl\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e32000-28-05-15-080-03-02\u003c\/strong\u003e è un gruppo alloggiamento della sonda di prossimità con filettatura metrica, progettato da Bently Nevada per sistemi di protezione di macchinari per impieghi gravosi. Progettato per l'installazione in ambienti impegnativi, come centrali elettriche con turbine a gas, raffinerie petrolchimiche e sistemi di propulsione navale, questo hardware rinforzato protegge i sensori a correnti parassite critici dagli urti meccanici esterni e dall'esposizione a sostanze chimiche. L'alloggiamento principale di giunzione è stampato a iniezione in solfuro di polifenilene (PPS) rinforzato con fibra di vetro, offrendo un'eccezionale stabilità dimensionale e dissipazione delle cariche statiche. Consentendo di regolare in sicurezza i giochi esterni della sonda e sostituire i sensori mentre la macchina monitorata rimane in funzione, questo gruppo elimina i guasti catastrofici e riduce drasticamente i costi di manutenzione dell'impianto.\u003c\/p\u003e\n\u003ch3\u003eAnalisi del suffisso\u003c\/h3\u003e\n\u003cul class=\"ybc-ul-component list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e32000:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGruppo base dell'alloggiamento della sonda di prossimità con filettatura metrica, dotato di un involucro di giunzione in termoplastica PPS ad alte prestazioni e resistente alla corrosione.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-28:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGruppo integrato della sonda di prossimità 3300 XL da 8 mm con omologazioni per enti certificatori per ambienti pericolosi.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-05:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOpzione di lunghezza del cavo non armato della sonda configurata a 0,5 metri (20 pollici).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-15:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eLunghezza dell'adattatore del distanziatore esteso lavorata con precisione a 150 mm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-080:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eLunghezza standard di penetrazione del manicotto della sonda impostata su 80 mm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-03:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConfigurazione dei raccordi comprendente due tappi ciechi antideflagranti, un raccordo di ingresso per conduit M20 e uno speciale pressacavo con tenuta.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-02:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConnessione di montaggio con filettatura di accoppiamento esterna 3\/4-14 NPT per l'installazione dell'adattatore del distanziatore rigido.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifiche tecniche\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\n\u003cp\u003eParametro\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eSpecifiche\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eModello\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e32000-28-05-15-080-03-02\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMarca\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eBently Nevada\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOrigine\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eStati Uniti\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eTipo di prodotto\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGruppo alloggiamento della sonda di prossimità\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMateriale dell'involucro\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSolfuro di polifenilene (PPS) caricato con fibra di vetro\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMateriale del manicotto e del distanziatore\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAcciaio inossidabile AISI 304\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eTipo di trasduttore\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSonda di prossimità 3300 XL da 8 mm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eLunghezza del distanziatore\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e150 mm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eProfondità di penetrazione\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e80 mm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eInterfaccia di montaggio\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e3\/4-14 NPT esterna\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFilettatura di ingresso del conduit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eM20 x 1,5\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eGrado di protezione dall'ingresso\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIP66 \/ Tipo 4X\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eIntervallo di temperatura ambiente\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eDa -35 a 177 °C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePeso approssimativo\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2,2 kg\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eDimensioni\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e315 mm x 115 mm x 115 mm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDomande frequenti operative\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQual è la differenza strutturale fondamentale tra questo modello e la variante con distanziatore più corto -08?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIl suffisso -15 indica una lunghezza estesa di 150 mm dell’adattatore distanziatore. Questa configurazione estesa offre uno spazio aggiuntivo per superare spessi materassini isolanti termici o complesse reti di tubazioni esterne comunemente presenti su turbine a vapore o a gas ad alta temperatura.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCome si comporta l’alloggiamento in plastica PPS quando è esposto a sostanze chimiche industriali aggressive?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eLa struttura in PPS rinforzato con fibra di vetro presenta un’eccellente inerzia chimica. Resiste all’esposizione prolungata a lubrificanti sintetici, ammoniaca, acido solfidrico e agenti caustici di lavaggio senza incrinarsi, corrodersi o perdere le proprie proprietà dissipative statiche.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eÈ necessario un cavo di messa a terra esterno per questo alloggiamento di giunzione non metallico?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. La formulazione avanzata in PPS è progettata intrinsecamente per dissipare le cariche elettrostatiche. Tuttavia, l’adattatore distanziatore e il manicotto in acciaio inossidabile forniscono un collegamento diretto metallo-metallo con il carter della macchina, garantendo un’adeguata messa a terra del sistema.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eDirettive per la messa in servizio sul campo e la sicurezza\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eAdattamento meccanico iniziale\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIspezionare le filettature della porta della macchina prima dell’installazione. Avvitare il manicotto in acciaio inossidabile attraverso l’adattatore di montaggio 3\/4-14 NPT finché la punta della sonda 3300 XL non si posiziona con attenzione contro l’area dell’albero target.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAllineamento dell’intervallo lineare\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCollegare un multimetro digitale standard tra le linee del segnale e COM del monitor Proximitor corrispondente. Svitare lentamente il manicotto finché la tensione di gap CC raggiunge -10,0 VCC (il punto medio nominale dell’intervallo lineare di 80 mil) prima di bloccarlo.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplicazione della coppia\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFissare il gruppo del controdado esterno utilizzando una chiave calibrata con un limite di coppia di 34 N-m. Il superamento di questo limite di coppia durante la manipolazione dell’alloggiamento strutturale in polimero PPS può causare lo spanamento localizzato della filettatura o la fratturazione dell’involucro.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProtezione dell’instradamento dei cavi\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eInstradare il cavo interno della sonda da 0,5 metri attraverso il pressacavo fornito, evitando curve strette sulla linea coassiale. Assicurarsi di mantenere all’interno dell’involucro un raggio di curvatura minimo di 25,4 mm (1,0 pollice).\u003c\/p\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666541146475,"sku":"32000-28-05-15-080-03-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-32000-28-05-15-080-03-02-metric-proximity-probe-housingassemblies-tpqyhvp4a0q_4a8a7495-09e1-4093-b084-023216670481.jpg?v=1765440468"},{"product_id":"bently-nevada-991-25-70-01-05-thrust-transmitter","title":"Bently Nevada 991-25-70-01-05 Trasmettitore di spinta","description":"\u003cp\u003eIl Bently Nevada 991-25-70-01-05 è un trasmettitore di spinta (spostamento assiale) a 2 fili, alimentato dall’anello, sviluppato per applicazioni OEM di monitoraggio dei macchinari su compressori, pompe, motori e apparecchiature rotanti. Converte il segnale della sonda di prossimità in un’uscita standard da 4–20 mA per l’integrazione diretta con PLC, DCS o sistemi di controllo.\u003c\/p\u003e\n\u003ch3\u003eInformazioni per l’ordine\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eCodice suffissoOpzione \/ ParametroDescrizione tecnica\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003e-25\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eOpzione di fondo scala\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e25-0-25 mil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003e-70\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eOpzione di lunghezza del sistema\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003e7,0 metri (23,0 piedi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003e-01\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eOpzione di montaggio\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eClip per guida DIN da 35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003e-05\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eOpzione di approvazione dell’ente\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eApprovazioni CSA Divisione 2, ATEX Zona 0, ATEX Zona 2 e ABS per uso marittimo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCaratteristiche principali\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCircuito integrato di pilotaggio della sonda di prossimità\u003c\/li\u003e\n\u003cli\u003eUscita proporzionale allo spostamento assiale da 4–20 mA\u003c\/li\u003e\n\u003cli\u003eRegolazioni indipendenti di Zero e Span\u003c\/li\u003e\n\u003cli\u003eSoppressione del segnale all’accensione per evitare falsi interventi\u003c\/li\u003e\n\u003cli\u003eDiagnostica di soppressione del segnale “Non OK”\u003c\/li\u003e\n\u003cli\u003eConnettore dedicato per il segnale dinamico PROX OUT\u003c\/li\u003e\n\u003cli\u003eStruttura incapsulata per ambienti ad alta umidità\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifiche\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eParametroDescrizione\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eSonda compatibile\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eSonda di prossimità 3300 NSv\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eSegnale di uscita\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eAnello CC da 4–20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eAlimentazione\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eDa +12 a +35 Vcc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eUscita dinamica\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eConnettore coassiale PROX OUT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eGrado di umidità\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e100% con condensa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003ePeso netto\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e0,43 kg (0,95 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003eMontaggio\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003eGuida DIN da 35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFasi di installazione\u003c\/h3\u003e\n\u003ch4\u003eMontaggio meccanico fisico\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eAgganciare il trasmettitore a una guida DIN standard da 35 mm\u003c\/li\u003e\n\u003cli\u003eInstallare lontano da fonti di alta temperatura\u003c\/li\u003e\n\u003cli\u003eUtilizzare un involucro in acciaio inossidabile 304 per gli ambienti esterni\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eInstallazione e distanza della sonda\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eUtilizzare esclusivamente sistemi con sonda 3300 NSv abbinati\u003c\/li\u003e\n\u003cli\u003eMantenere la lunghezza totale del cavo del sistema esattamente a 7,0 metri\u003c\/li\u003e\n\u003cli\u003eVerificare che l’area di rilevamento dell’albero soddisfi i requisiti minimi di dimensionamento\u003c\/li\u003e\n\u003cli\u003eRegolare la sonda sul punto medio dell’intervallo operativo lineare\u003c\/li\u003e\n\u003cli\u003eConfermare che la tensione PROX OUT sia di circa 6,5 Vcc\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCablaggio del circuito elettrico\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eCollegare il trasmettitore a un'alimentazione del circuito da +12 a +35 Vcc\u003c\/li\u003e\n\u003cli\u003eVerificare la polarità di Power (+) e Signal (-) prima di alimentare il sistema\u003c\/li\u003e\n\u003cli\u003eSerrare saldamente il connettore coassiale miniaturizzato\u003c\/li\u003e\n\u003cli\u003eCollegare la schermatura del cavo a massa solo sul lato dell'armadio di controllo\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCalibrazione di Zero e Span\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRegolare il potenziometro Zero nella posizione centrale meccanica\u003c\/li\u003e\n\u003cli\u003eImpostare la corrente di uscita del circuito a 12 mA durante la calibrazione del punto centrale\u003c\/li\u003e\n\u003cli\u003eRegolare il potenziometro Span alla massima corsa\u003c\/li\u003e\n\u003cli\u003eI potenziometri indipendenti minimizzano le iterazioni di ricalibrazione\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDomande frequenti\u003c\/h3\u003e\n\u003ch4\u003ePerché è importante la distanza iniziale della sonda?\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eDistanze errate limitano l'intervallo di misura utilizzabile\u003c\/li\u003e\n\u003cli\u003eUn'installazione non corretta può consentire il contatto tra la sonda e il rotore\u003c\/li\u003e\n\u003cli\u003eLa distanza operativa deve rimanere compresa tra 0,25 e 1,65 mm (10 e 65 mil)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003ePerché la corrente del circuito scende al di sotto di 3,6 mA?\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eIl trasmettitore è entrato in modalità di protezione “Not OK”\u003c\/li\u003e\n\u003cli\u003eLa sonda o il cavo di prolunga potrebbero essere interrotti o in cortocircuito\u003c\/li\u003e\n\u003cli\u003eIl connettore coassiale potrebbe non essere inserito completamente\u003c\/li\u003e\n\u003cli\u003eL'uscita failsafe impedisce falsi segnali di intervento del PLC o del DCS\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eÈ possibile collegare un oscilloscopio direttamente alla porta PROX OUT?\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eIl connettore PROX OUT non è isolato dal circuito 4–20 mA\u003c\/li\u003e\n\u003cli\u003eGli oscilloscopi standard con messa a terra possono creare anelli di massa\u003c\/li\u003e\n\u003cli\u003eUtilizzare invece un misuratore alimentato a batteria o un adattatore di interfaccia isolato\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eÈ possibile accorciare o giuntare il cavo di prolunga?\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eÈ severamente vietato modificare la lunghezza del cavo\u003c\/li\u003e\n\u003cli\u003eLe variazioni di impedenza del cavo influiscono sulla precisione della calibrazione\u003c\/li\u003e\n\u003cli\u003eAccorciare o allungare il cavo invalida la calibrazione di fabbrica\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNote sulla compatibilità\u003c\/h3\u003e\n\u003cp\u003eIl trasmettitore è progettato specificamente per l'uso con:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSistemi di sonde di prossimità Bently Nevada 3300 NSv\u003c\/li\u003e\n\u003cli\u003eCompressori centrifughi OEM\u003c\/li\u003e\n\u003cli\u003ePiccole pompe e macchinari rotanti\u003c\/li\u003e\n\u003cli\u003eSistemi di ingressi analogici PLC e DCS\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666735296875,"sku":"991-25-70-01-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-991-25-70-01-05-thrust-transmitter-4nnys1eggun_8af749c8-fb0e-4137-a612-cfed2c951e30.jpg?v=1765446775"},{"product_id":"bently-nevada-9200-06-02-10-00-two-wire-transducer","title":"Bently Nevada 9200-06-02-10-00 Trasduttore a due fili","description":"\u003cp\u003eIl \u003cstrong\u003e9200\u003c\/strong\u003e trasduttore di velocità standard, numero di parte completo \u003cstrong\u003e9200-06-02-10-00\u003c\/strong\u003e, è un trasduttore a bobina mobile a due fili progettato per misurare la vibrazione assoluta dell’alloggiamento nei macchinari rotanti. Il sistema meccanico presenta una bobina sospesa tramite fili che si muove attorno a un magnete permanente, fornendo un’uscita in tensione direttamente proporzionale alla velocità di vibrazione. Questo sensore autogenerante non richiede alimentazione esterna e funziona all’interno di una finestra di orientamento dedicata, definita dalla configurazione dell’opzione specifica. La serie 9200 utilizza principi di dinamica del rotore per monitorare continuamente il movimento strutturale dell’alloggiamento, garantendo la protezione dei macchinari critici e interfacciandosi direttamente con i sistemi di monitoraggio Bently Nevada tramite trasmissione del segnale a bassa impedenza.\u003c\/p\u003e\n\u003ch3\u003eInformazioni per l’ordinazione\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e-06: Angolo di montaggio del trasduttore \/ Frequenza operativa minima\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e0 ±100° (orientamento di posizionamento orizzontale), frequenza operativa minima di 10 Hz (600 cpm).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterfaccia con connettore ermetico a 2 pin per montaggio laterale.\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e-02: Opzione del connettore\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGeometria della base circolare con collegamento tramite prigioniero filettato M10X1.\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e-10: Opzione della base di montaggio\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-00: Opzione di approvazione dell’agenzia\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eNon sono richieste approvazioni o certificazioni standard per aree pericolose.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifiche hardware\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParametro\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecifica\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduttore\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumero di parte\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9200-06-02-10-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTipo di trasduttore\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eA bobina mobile a due fili\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrientamento di montaggio\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 ±100° (orizzontale)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequenza operativa minima\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 Hz (600 cpm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrientamento del connettore\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMontaggio laterale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGeometria della base di montaggio\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCircolare con prigioniero filettato M10X1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMateriale dell’alloggiamento e dell’adattatore\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAlluminio anodizzato A204\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAltezza del sensore\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e102 mm tipici\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiametro del sensore\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e41 mm tipici\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApprovazioni\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNessuna\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eNote di progettazione\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAssicurarsi che l’angolo di installazione del sensore corrisponda esattamente alla specifica dell’intervallo orizzontale 0 ±100° per evitare che la bobina interna si blocchi fisicamente contro l’alloggiamento del magnete.\u003c\/li\u003e\n\u003cli\u003eIl funzionamento del trasduttore al di sotto del limite di frequenza specificato di 10 Hz causa una significativa attenuazione dell’ampiezza e errori di sfasamento nei dati di velocità.\u003c\/li\u003e\n\u003cli\u003eLa sensibilità alle vibrazioni trasversali deve essere ridotta al minimo allineando l’asse di misurazione principale direttamente parallelo alla direzione prevista della vibrazione del macchinario.\u003c\/li\u003e\n\u003cli\u003eIl gruppo bobina autoalimentato introduce un’impedenza interna fissa che deve essere adattata agli ingressi di strumentazione di monitoraggio compatibili, per prevenire effetti di carico sul segnale.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eLinee guida per l’installazione sul campo\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eImplementare protocolli dedicati per la messa a terra della schermatura, collegando la schermatura del cavo solo all’estremità del rack di monitoraggio e mantenendo isolata l’estremità del trasduttore, per eliminare i loop di massa.\u003c\/li\u003e\n\u003cli\u003eMantenere un’adeguata separazione del percorso dei cavi, separando le linee di segnale del trasduttore dalle canaline di distribuzione dell’alimentazione CA ad alta tensione, per ridurre le interferenze elettromagnetiche.\u003c\/li\u003e\n\u003cli\u003eEvitare di superare il raggio minimo di curvatura del cavo di cablaggio di campo, per prevenire danni ai conduttori interni o il deterioramento della barriera isolante.\u003c\/li\u003e\n\u003cli\u003eVerificare l’integrità strutturale della superficie di montaggio M10X1, assicurandosi che sia piana, liscia e priva di vernice o detriti, per garantire una trasmissione accurata delle vibrazioni ad alta frequenza.\u003c\/li\u003e\n\u003cli\u003eApplicare le specifiche di coppia corrette durante il fissaggio della base circolare di montaggio alla carcassa della macchina, per evitare che le frequenze di risonanza distorcano le letture della velocità.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDomande frequenti tecniche e sugli acquisti\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eD: Questo modello 9200-06-02-10-00 può essere montato in posizione esclusivamente verticale su una carcassa della macchina?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eR: No, il suffisso -06 designa una configurazione di montaggio orizzontale di 0 ±100 gradi; il montaggio verticale richiede un diverso codice opzione per calibrare l’allineamento interno della molla e della bobina.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eD: Quali componenti sono inclusi nella confezione di spedizione per questo specifico codice prodotto?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eR: La confezione contiene il gruppo trasduttore di velocità originale nuovo di zecca 9200-06-02-10-00, con connettore integrato montato lateralmente e perno circolare della base di montaggio M10X1.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eD: Questo specifico modulo trasduttore richiede un alimentatore esterno separato per emettere il segnale di velocità?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No, si tratta di un sensore elettromagnetico a bobina mobile autoalimentato che produce una propria tensione di uscita proporzionale alla velocità, senza richiedere alimentazione esterna del circuito.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666764493163,"sku":"9200-06-02-10-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-9200-06-02-10-00-two-wire-transducer-wh1b32koul4_e61ad530-9ea0-4ba5-a008-11769c81ce20.jpg?v=1765447197"},{"product_id":"bently-nevada-125712-01-spare-4-channel-relay-module","title":"Bently Nevada 125712-01 modulo relè di riserva a 4 canali","description":"\u003ch3\u003eDescrizione\u003c\/h3\u003e\n\u003cp\u003eIl \u003cstrong\u003e125712-01\u003c\/strong\u003e è un modulo di ricambio a tutta altezza progettato per fornire quattro uscite a relè programmabili indipendenti all'interno di un sistema di protezione dei macchinari. Funziona come componente principale del sistema \u003cstrong\u003e3500\/32\u003c\/strong\u003e, consentendo all'utente di programmare la logica di votazione per attivare allarmi automatici specifici in base alle condizioni della macchina. Ogni uscita integra la \u003cstrong\u003elogica di attivazione degli allarmi\u003c\/strong\u003e, consentendo configurazioni complesse di porte AND e OR che utilizzano ingressi di avviso e pericolo aggregati da qualsiasi combinazione di canali di monitoraggio all'interno dello stesso rack. Il modulo si interfaccia perfettamente con le schede di terminazione del backplane compatibili per attivare sistemi di sicurezza, meccanismi di arresto di emergenza o indicatori esterni su diversi asset rotanti ad alta criticità.\u003c\/p\u003e\n\u003ch3\u003eCaratteristiche\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eQuattro canali a relè indipendenti e altamente configurabili, in grado di elaborare la logica di votazione dei singoli asset.\u003c\/li\u003e\n\u003cli\u003eLa \u003cstrong\u003elogica di attivazione degli allarmi\u003c\/strong\u003e avanzata supporta strutture combinatorie AND\/OR per ottimizzare le sequenze di arresto protettivo.\u003c\/li\u003e\n\u003cli\u003ePosizionamento flessibile nello slot, che consente l'installazione in qualsiasi slot disponibile a destra del modulo di interfaccia del rack.\u003c\/li\u003e\n\u003cli\u003eIndicatori diagnostici completi sul pannello frontale che mostrano lo stato operativo (OK), le comunicazioni attive con il rack (TX\/RX) e gli stati di allarme indipendenti dei canali.\u003c\/li\u003e\n\u003cli\u003eSoppressori d'arco integrati e forniti di serie per mitigare in sicurezza le sovratensioni elettriche sui carichi di uscita.\u003c\/li\u003e\n\u003cli\u003eFacilmente programmabile tramite l'utility software specializzata per adattarsi ai criteri specifici del sistema.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplicazioni\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCircuiti di protezione ad alta velocità per turbomacchine e compressori.\u003c\/li\u003e\n\u003cli\u003eLogica di sicurezza automatizzata per le apparecchiature di generazione elettrica e le pompe industriali.\u003c\/li\u003e\n\u003cli\u003eInterfacciamento degli indicatori di condizioni critiche con i sistemi di controllo distribuito (\u003cstrong\u003eDCS\u003c\/strong\u003e) e i sistemi di arresto di emergenza (\u003cstrong\u003eESD\u003c\/strong\u003e).\u003c\/li\u003e\n\u003cli\u003eSistemi di monitoraggio delle vibrazioni multicanale in cui i criteri di votazione logica impediscono falsi arresti del processo.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInformazioni per l'ordine\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eNumero di parte \/ codice opzione\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescrizione\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/32-AXX-BXX\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConfigurazione completa del gruppo del modulo a relè a 4 canali.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA: 01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModulo I\/O a relè a 4 canali.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB: 00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOpzione di omologazione: nessuna.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB: 01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOpzione di omologazione: CSA\/NRTL\/C.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e125712-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eParti di ricambio:\u003c\/strong\u003e modulo a relè di ricambio a 4 canali.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e125720-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eParti di ricambio:\u003c\/strong\u003e modulo I\/O a relè di ricambio a 4 canali.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e132319-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eParti di ricambio:\u003c\/strong\u003e IC del firmware.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e00580436\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eParti di ricambio:\u003c\/strong\u003e Connettore maschio, terminazione interna, 6 posizioni, verde.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSpecifiche tecniche\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCategoria del parametro\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDettagli delle specifiche\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduttore\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCodice modello\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500\/32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumero di parte di ricambio\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e125712-01\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConsumo energetico\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 watt tipici\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConfigurazione del relè\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDue relè unipolari a due vie (SPDT) collegati in una configurazione bipolare a due vie (DPDT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTipo di sigillatura del relè\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSigillatura in resina epossidica\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSoppressore d'arco\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 Vrms, installato come standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDurata dei contatti\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100.000 cicli a 5 A, 24 Vcc o 120 Vca\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModalità di funzionamento del canale\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSelezionabile tramite interruttore per normalmente diseccitato o normalmente eccitato\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePotenza commutata resistiva\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCC max.: 120 W | CA max.: 600 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCarico minimo commutato\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 mA a 5 Vcc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCorrente massima commutata\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTensione massima commutata\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003eCC: 30 Vcc | CA: 250 Vca\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperatura di esercizio\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDa -30 °C a +65 °C (da -22 °F a +150 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperatura di stoccaggio\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDa -40 °C a +85 °C (da -40 °F a +185 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUmidità\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95%, senza condensa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensioni del modulo principale\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241 mm x 24,4 mm x 242 mm (9,50 pollici x 0,96 pollici x 9,52 pollici)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensioni del modulo I\/O\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241 mm x 24,4 mm x 99,1 mm (9,50 pollici x 0,96 pollici x 3,90 pollici)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePeso del modulo principale\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0,7 kg (1,6 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePeso del modulo I\/O\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0,4 kg (1,0 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRequisiti degli slot del rack\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 slot anteriore a tutta altezza per il modulo principale, 1 slot posteriore a tutta altezza per i moduli I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eCollegamenti\/Interfacce\u003c\/h3\u003e\n\u003cp\u003eLe configurazioni dell'interfaccia forniscono letture diagnostiche dedicate e morsetti di contatto per una segnalazione affidabile del loop:\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eElemento di interfaccia\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunzione \/ Assegnazione\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLED OK\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndicatore del pannello anteriore; rimane acceso quando il circuito interno funziona correttamente.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLED TX\/RX\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndicatore del pannello anteriore; lampeggia continuamente per segnalare la normale attività di comunicazione con il backplane del rack.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLED DI ALLARME CH (1 - 4)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndicatori indipendenti; si illuminano direttamente quando il relativo canale del relè attiva uno stato di allarme.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMorsetti di uscita\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMorsettiere di collegamento dei cavi sulla scheda posteriore utilizzate per collegare i punti di contatto ai sistemi di automazione dell'impianto.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterruttori hardware\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMeccanismi di controllo integrati utilizzati per definire lo stato operativo di base dei contatti di uscita.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eLinee guida per l'installazione\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePosizionamento del modulo:\u003c\/strong\u003e Inserire il componente in un singolo slot anteriore a tutta altezza dell'alloggiamento principale, posizionandolo a destra della scheda di interfaccia primaria.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMitigazione ESD:\u003c\/strong\u003e Prima di toccare o maneggiare le schede elettroniche, fissare un braccialetto di messa a terra antistatico approvato per ridurre il rischio di scariche elettrostatiche involontarie.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMappatura della logica:\u003c\/strong\u003e Aprire il framework dell’utility personalizzata per definire le mappe di intervento desiderate prima di testare i canali di uscita del sistema.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelezione dello stato:\u003c\/strong\u003e Posizionare manualmente gli interruttori di configurazione fisici per selezionare gli stati Normalmente eccitato o Normalmente diseccitato prima di mettere in servizio i circuiti del relè di uscita.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEsclusione TMR:\u003c\/strong\u003e Si noti che le opzioni standard a quattro canali non sono adatte ai circuiti a ridondanza modulare tripla; per l’architettura di protezione TMR, utilizzare il modello di assieme di votazione dedicato appropriato.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConformità e certificazioni\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEmissioni EMC:\u003c\/strong\u003e EN50081-2, EN 55011 Classe A (Emissioni condotte e irradiate).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eImmunità EMC:\u003c\/strong\u003e EN50082-2, EN 61000-4-2 (Criterio ESD B), ENV 50140 (Criterio di suscettibilità irradiata A), ENV 50141 (Criterio di suscettibilità condotta A), EN 61000-4-4 (Criterio EFT B), EN 61000-4-5 (Criterio di sovratensione B), EN 61000-4-8 (Criterio di campo magnetico A), EN 61000-4-11 (Criterio di caduta dell’alimentazione B), ENV 50204 (Criterio per telefoni radio B).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDirettive sulla bassa tensione:\u003c\/strong\u003e EN 61010-1 Requisiti di sicurezza.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNorme per aree pericolose:\u003c\/strong\u003e CSA\/NRTL\/C Classe I, Divisione 2, Gruppi da A a D.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDomande frequenti\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQual è la differenza specifica tra questo ricambio e un codice d’ordine standard 3500\/32?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIl modello 3500\/32 descrive la famiglia funzionale generale o la configurazione del sistema composta da più componenti, mentre il codice prodotto distinto definisce la singola scheda frontale sostituibile a caldo fornita come ricambio.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eÈ possibile assegnare manualmente questi canali relè agli allarmi su qualsiasi scheda di monitoraggio delle vibrazioni all’interno dello stesso telaio di sistema?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSì, l’algoritmo di elaborazione memorizzato internamente acquisisce i segnali operativi e gli stati di allarme da qualsiasi combinazione di slot standard nella configurazione attiva del rack.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCome si regola un canale relè tra il comportamento Normalmente eccitato e Normalmente diseccitato?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eLa configurazione desiderata richiede la regolazione dei singoli interruttori hardware fisici situati sull’assieme, oltre alla modifica dei parametri nell’utility di configurazione.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eUn componente standard 125712-01 viene fornito con il modulo di ingresso\/uscita posteriore corrispondente?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, questo codice prodotto designa specificamente la sola scheda principale del processore sul lato anteriore; se è necessaria la scheda di terminazione posteriore, deve essere ordinata con il relativo codice prodotto.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666847658347,"sku":"3500\/32 125712-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-32-125712-01-4-channel-relay-module-apgs2pgvaqc_1bd7426c-4cca-42dc-afd3-fce09079cbbe.jpg?v=1765448967"},{"product_id":"bently-nevada-134652-01-tdxnet-cpu-processor-board","title":"Bently Nevada 134652-01 TDXnet CPU Processor Board","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada \u003cstrong\u003e134652-01\u003c\/strong\u003e is a CPU Processor Board designed to provide the processing interface between compatible machinery protection systems and Bently Nevada on-line machinery management software. The \u003cstrong\u003e134652-01\u003c\/strong\u003e continuously collects steady-state and startup\/shutdown transient data in parallel from connected monitoring channels. Operating within the TDXnet communications processor, the board manages data collection, processes 4 Keyphasor input channels, and routes processed static, orbit, and spectrum data to host systems over Ethernet (IEEE 802.3 TCP\/IP) or RS485 serial multidrop SDI links.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eImmediate recovery from power loss\u003c\/li\u003e\n\u003cli\u003eHigh-resolution static, orbit, and spectrum data acquisition\u003c\/li\u003e\n\u003cli\u003eEthernet link to Data Manager 2000 host computers\u003c\/li\u003e\n\u003cli\u003eTwo independent startup\/shutdown data buffers and one independent delta-time buffer\u003c\/li\u003e\n\u003cli\u003eParallel collection of steady-state and startup\/shutdown data\u003c\/li\u003e\n\u003cli\u003eKeyphasor-based startup and shutdown data acquisition eliminating external contact closures\u003c\/li\u003e\n\u003cli\u003eRS485 multidrop interface supporting Allen-Bradley and Modbus SDI protocols\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOnline machinery condition monitoring and transient data acquisition\u003c\/li\u003e\n\u003cli\u003eReal-time startup and coastdown data processing for industrial rotating machinery\u003c\/li\u003e\n\u003cli\u003eSystem interface for Bently Nevada 3500, 3300, and 2201 Machinery Protection Systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e134652-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eComponent Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTDXnet CPU Processor Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKeyphasor Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 per unit, 60 to 60,000 rpm range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEthernet Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 Mbps, conforming to IEEE 802.3 (RJ-45 and 15-pin AUI connections)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEthernet Protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTCP\/IP encapsulating Bently Nevada proprietary protocol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSerial SDI Communications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS485 multidrop link supporting Allen-Bradley and Modbus protocols\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWaveform Sampling Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC coupled, ±25 Volts input with up to 25 Volts peak-to-peak AC signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSynchronous Waveform Sampling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUser configurable: 128 samples\/rev (8 revs), 64 samples\/rev (16 revs), 32 samples\/rev (32 revs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAsynchronous Waveform Sampling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupports 400-line Spectrum at 20 kHz frequency span (anti-alias filtered)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransient Buffers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 independent Startup\/Shutdown buffers, 1 independent Delta-Time buffer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuffer Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e320 vector records and 32 waveform records per delta time\/RPM buffer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+90 to +240 Vac, 50 to 60 Hz; 89 Watts maximum power consumption\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 degC to +65 degC (+32 degF to +149 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC (-40 degF to +185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0% to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eConnector Pin\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRJ-45 \/ 15-pin AUI\u003c\/td\u003e\n\u003ctd\u003eEthernet 10Base-T \/ 10Base-2 network interface to host computer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRS485 SDI Port\u003c\/td\u003e\n\u003ctd\u003eSerial Distributed Interface link for DCS\/Modbus\/Allen-Bradley communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDynamic \/ Static Connectors\u003c\/td\u003e\n\u003ctd\u003eConnection interfaces to monitoring system racks (3500, 3300, 2201)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKeyphasor Inputs\u003c\/td\u003e\n\u003ctd\u003eTerminal\/connector interface for 4 Keyphasor transducer signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure the TDXnet enclosure is isolated from line power before installing or removing circuit boards.\u003c\/li\u003e\n\u003cli\u003eMount the CPU board securely inside the designated slot within the TDXnet communications processor assembly.\u003c\/li\u003e\n\u003cli\u003eMaintain proper electrostatic discharge (ESD) precautions during handling; handle circuit assemblies by the edges or shield handles.\u003c\/li\u003e\n\u003cli\u003eRoute Ethernet cables and RS485 serial communication cabling away from high-voltage lines to minimize signal interference.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard \/ Directive\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC Directives\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCertificate 158809: EN50081-2 (EN55011 Class A Radiated\/Conducted Emissions), EN50082-2 (ENV50140, ENV50204, ENV50141, EN61000-4-2, EN61000-4-4, EN61000-4-8, EN61000-4-11)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLow Voltage Directives\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCertificate 158809: EN61010-1 Safety Requirements, EN61000-3-2:1995 Harmonic Content\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCSA\/NRTL\/C Approval\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOption (01): Class 1, Division 2, Groups A, B, C, D; T4 @ Ta = 65 degC (Certification CSA 150368 \/ LR 26744)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666852508011,"sku":"134652-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-134652-01-transient-data-interface-card-gbg00mtzmmz_e61454ba-70f2-492c-a47d-cfca8e26c851.jpg?v=1765449086"},{"product_id":"honeywell-mc-taih02-51304453-150-tps-process-manage-high-level-analog-input-sti-fta","title":"Honeywell MC-TAIH02 51304453-150 TPS Process Manage High Level Analog Input\/STI FTA","description":"\u003cp\u003eThe Honeywell \u003cstrong\u003eMC-TAIH02\u003c\/strong\u003e is a High Level Analog Input \/ Smart Transmitter Interface Field Termination Assembly (FTA) designed for process signal termination and field wiring interfacing within TotalPlant Solution (TPS) Process Manager systems.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAccommodates up to 16 differential input channels for analog voltage\/current signals or digital smart transmitter communications.\u003c\/li\u003e\n\u003cli\u003eIntegrates resistor current limiting (145 ohm, non-fused) for transmitter power conditioning in Class 1, Div 2 hazardous location interfacing.\u003c\/li\u003e\n\u003cli\u003eFeatures compression-type termination blocks capable of accepting wire sizes up to 14 AWG (~1.6 mm).\u003c\/li\u003e\n\u003cli\u003eSupports high-density A-size assembly footprint for cabinet space efficiency.\u003c\/li\u003e\n\u003cli\u003eProvided with standard conformal coating for harsh environment and corrosion protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-level analog voltage and current field loop terminations\u003c\/li\u003e\n\u003cli\u003eSmart Transmitter Interface (DE protocol) field device wiring\u003c\/li\u003e\n\u003cli\u003eProcess Manager (PM), Advanced Process Manager (APM), High Performance Process Manager (HPM), and Enhanced High Performance Process Manager (EHPM) I\/O subsystems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMC-TAIH02\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e51304453-150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBase Model Equivalent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMU-TAIH02 (Conformally Coated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 differential channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible IOP Modules\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMC-PAIH03, MU-PSTX03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Signal Types\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVoltage, current (2-wire or self-powered), Honeywell DE protocol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmitter Power Conditioning\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResistor Current Limited (145 ohm, not fused)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Block Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCompression-Type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Wire Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 AWG (~1.6 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFTA Assembly Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSize A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConformally Coated (G3 \/ Harsh Atmosphere rating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSurge Withstand Capability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eANSI\/IEEE C37.90.1-1978\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Wiring Connection:\u003c\/strong\u003e Route field wiring to the compression terminals ensuring conductors do not exceed 14 AWG (~1.6 mm).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Common Reference:\u003c\/strong\u003e The low-side input connection is normally connected to system common via a wire jumper on the FTA, which can be removed subject to operating within Common Mode Voltage limits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Routing:\u003c\/strong\u003e Connect the FTA to the corresponding Input\/Output Processor (IOP) using approved Honeywell FTA cables up to 50 meters in length.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCorrosion Protection:\u003c\/strong\u003e Maintain conformal coating integrity when installed in non-G1 process environments.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667747041643,"sku":"MC-TAIH02 51304453-150","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/MC-TAIH02-51304453-150_001_1200x1200_8abf2705-8fd1-4415-8072-1ee73a4082cf.jpg?v=1786518694"},{"product_id":"honeywell-k4lcn-16-51403519-160-lcn-node-processor-board","title":"Honeywell K4LCN-16 51403519-160 LCN Node Processor Board","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell K4LCN-16 51403519-160\u003c\/strong\u003e is a Local Control Network (LCN) node processor board designed for high-performance computing within Honeywell TotalPlant Solution (TPS) and TDC 3000X system environments. It functions as the central LCN node processor kernel, executing core control system software, managing Local Control Network point data, and providing the processing baseline required for advanced process control and Application ModuleX (AXM) coprocessor integration.\u003c\/p\u003e\n\u003cp\u003eFeaturing a 68040 microprocessor with integrated floating-point calculation hardware, the \u003cstrong\u003eHoneywell K4LCN-16 51403519-160\u003c\/strong\u003e provides on-board processing speed and execution capacity for complex control algorithms, custom data segments, and Control Language (CL) applications. The board is equipped with 16 megawords of memory via a horizontally pluggable DIMM-style mezzanine board assembly (51402755-100), fulfilling the expanded memory requirements needed for TPS Software Release 500 and later.\u003c\/p\u003e\n\u003cp\u003eOperating in five-slot chassis configurations, the \u003cstrong\u003eHoneywell K4LCN-16 51403519-160\u003c\/strong\u003e interfaces directly with the LCN backplane through an associated CLCN A\/B I\/O or LCN I\/O board. In Application ModuleX architectures, it operates alongside an HP-UX-based coprocessor (WSI2 assembly) to bridge high-level UNIX process control solutions with low-level TDC 3000 real-time plant data structures.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDriven by a 68040 processor with dedicated floating-point calculation hardware capability for high-speed control execution.\u003c\/li\u003e\n\u003cli\u003eEquipped with 16 megawords of on-board memory utilizing a Dual In-line Memory Module (DIMM) style mezzanine card.\u003c\/li\u003e\n\u003cli\u003eServes as the LCN node processor kernel supporting TotalPlant Solution (TPS) system software Release 500 and later.\u003c\/li\u003e\n\u003cli\u003eDirect integration capability with HP-UX coprocessors (WSI2 boards) in Application ModuleX (AXM) node architectures.\u003c\/li\u003e\n\u003cli\u003eComprehensive front-edge visual diagnostic status array, including a 3-digit alphanumeric Node Address\/Error Display.\u003c\/li\u003e\n\u003cli\u003eOn-board Error Detection and Correction (EDAC) with LED indication for single-bit and multi-bit RAM errors.\u003c\/li\u003e\n\u003cli\u003eIntegrated diagnostic tracking for DTAK timeout, BGAK timeout, bus parity errors, data compare errors, and LCN transaction failures.\u003c\/li\u003e\n\u003cli\u003eBackplane compatibility with CLCN A\/B I\/O and standard LCN I\/O cards for dual-redundant coaxial LCN cable connections.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotalPlant Solution (TPS) LCN Nodes:\u003c\/strong\u003e Functions as the primary processing engine for LCN-based system nodes requiring high-speed floating-point computations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication ModuleX (AXM) Execution:\u003c\/strong\u003e Executes real-time Control Language (CL) routines, maintains LCN point databases, and interfaces directly with HP-UX coprocessor solutions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLegacy TDC 3000X Upgrades:\u003c\/strong\u003e Provides memory expansion to 16 megawords required when upgrading system software to Release 500 or higher.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlant Information Network (PIN) Data Gateway:\u003c\/strong\u003e Serves as the real-time control link bridging LCN process data with higher-level plant information networks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e51403519-160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Identifier\u003c\/td\u003e\n\u003ctd\u003eK4LCN-16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor Architecture\u003c\/td\u003e\n\u003ctd\u003eMotorola 68040 with integrated floating-point unit (FPU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Capacity\u003c\/td\u003e\n\u003ctd\u003e16 Megawords\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Board Style\u003c\/td\u003e\n\u003ctd\u003eDIMM-style mezzanine board (Assembly 51402755-100)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSoftware Compatibility\u003c\/td\u003e\n\u003ctd\u003eTotalPlant Solution (TPS) R500 and later\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardware Chassis Compatibility\u003c\/td\u003e\n\u003ctd\u003e5-Slot LCN Chassis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNode Address Display\u003c\/td\u003e\n\u003ctd\u003e3-digit alphanumeric LED display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostic Status LEDs (Red)\u003c\/td\u003e\n\u003ctd\u003eRST\/PWR Fail, Self-Test Error, Data Compare Error, DTAK Time Out, BGAK Time Out, Data Parity Error, Bus Error, EDAC Single-Bit Error, EDAC Multi-Bit Error, LCN Transaction Error\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostic Status LEDs (Green)\u003c\/td\u003e\n\u003ctd\u003eSelf-Test Pass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostic Status LEDs (Yellow)\u003c\/td\u003e\n\u003ctd\u003eTX (LCN Transmit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Redundancy Support\u003c\/td\u003e\n\u003ctd\u003eDual LCN coaxial connections via CLCN A\/B I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eInterface \/ Component\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Edge Connector\u003c\/td\u003e\n\u003ctd\u003eModule bus interface for power, data, and system bus communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMezzanine Memory Connector\u003c\/td\u003e\n\u003ctd\u003eInterface for 16 Megaword DIMM memory board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTS1 \/ TS2 Pinning Block\u003c\/td\u003e\n\u003ctd\u003eOn-board LCN address pinning (Must have all jumpers removed when used with CLCN A\/B I\/O or LCN I\/O board)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003ePre-Installation Inspection:\u003c\/strong\u003e Verify the physical integrity of the circuit board, edge connectors, and the mounted 16 Megaword memory mezzanine card (51402755-100).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAddress Pinning Verification:\u003c\/strong\u003e Ensure all LCN address jumpers on the K4LCN-16 board (TS1\/TS2 block) are completely removed when installing behind a CLCN A\/B I\/O or LCN I\/O card. Pinning must be set exclusively on the rear I\/O board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Preparation:\u003c\/strong\u003e Confirm system power is switched OFF at the node power supply. Electrostatic Discharge (ESD) protective grounding must be used during handling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBoard Mounting:\u003c\/strong\u003e Slide the board into Slot 1 of the 5-slot LCN chassis until the backplane connectors seat firmly. Secure the board using the top and bottom extraction\/insertion levers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Cabling Check:\u003c\/strong\u003e Confirm that LCN Coax A and Coax B network cables are securely attached to the corresponding CLCN A\/B rear I\/O card.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eReplacement Recommendations\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSoftware Shutdown:\u003c\/strong\u003e Before removing power, execute an orderly node processor software shutdown via the LCN AM Status display. Perform a second shutdown command to force the node into a failed state, preventing surrounding LCN nodes from marking it isolated.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Down Sequence:\u003c\/strong\u003e Turn off the chassis power supply only after confirming that dependent coprocessor systems (such as the WSI2 board yellow LED) have completely shut down.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMemory Board Handling:\u003c\/strong\u003e Replacement K4LCN boards ordered from spare parts may arrive without the memory mezzanine board. Transfer or install a dedicated 16 Megaword board prior to insertion.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePost-Replacement Commissioning:\u003c\/strong\u003e Apply power and observe the front panel LEDs. Ensure the green \"Self-Test Pass\" LED illuminates and the 3-digit display correctly reflects the node address assigned on the rear LCN I\/O board.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667754938731,"sku":"K4LCN-16 51403519-160","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-k4lcn-16-51403519-160-control-board-bdewkwo0fya_ff9df4ad-ee56-4ef3-bd5c-82c2ab988de8.jpg?v=1765501620"},{"product_id":"honeywell-fc-iochas-0001s-safety-manager-i-o-chassis","title":"Honeywell FC-IOCHAS-0001S Safety Manager I\/O Chassis","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell FC-IOCHAS-0001S\u003c\/strong\u003e is a single I\/O chassis designed for process safety, emergency shutdown (ESD), and critical control applications in industrial environments. Constructed to accommodate Safety Manager I\/O modules and associated bus components, the assembly features a 19-inch rack-mountable form factor with integrated backplane interconnects, key coding positions, and power distribution interfaces for process automation architectures.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for single Safety Manager controller configurations requiring dedicated I\/O expansion.\u003c\/li\u003e\n\u003cli\u003eEquipped with backplane connectors featuring SOURIAU 5159 mechanical key coding pin positions to prevent module misplacement.\u003c\/li\u003e\n\u003cli\u003eProvides integrated bus printed circuit board (PCB) routing for internal 5 Vdc logic power distribution and watchdog signals.\u003c\/li\u003e\n\u003cli\u003eIncorporates card connector slots for standard input, output, and special-function modules.\u003c\/li\u003e\n\u003cli\u003eFeatures robust mechanical mounting design compatible with standard 19-inch cabinet frames and swing frame structures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSafety Instrumented Systems (SIS)\u003c\/li\u003e\n\u003cli\u003eEmergency Shutdown Systems (ESD)\u003c\/li\u003e\n\u003cli\u003eFire and Gas Detection Systems (F\u0026amp;G)\u003c\/li\u003e\n\u003cli\u003eBurner Management Systems (BMS) and Boiler Protection\u003c\/li\u003e\n\u003cli\u003eCritical Process Control in Chemical, Petrochemical, and Energy Plants\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFC-IOCHAS-0001S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSafety Manager I\/O Chassis (Single)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSub-assembly \/ Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIOCHAS-0001S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConformal Coated (FC Prefix)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5 degC to 70 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 degC to 85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5% to 95% (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSinusoidal Vibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 to 57 Hz: 0.075 mm amplitude; 57 to 150 Hz: 1 G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical Shock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 G peak acceleration (11 ms pulse duration, 3 axes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24 Vdc Supply Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 Vdc (+30% \/ -15%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKey Coding System\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSOURIAU type 5159 (pins 5159.009.17.22)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIngress Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP 20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCabinet Mount:\u003c\/strong\u003e Install the chassis securely inside a standard cabinet or 180-degree swing frame using appropriate captive nuts and mounting hardware.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Keying:\u003c\/strong\u003e Ensure that all backplane chassis pin positions are properly populated with SOURIAU 5159 coding pins matching the intended I\/O module type prior to card insertion.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower \u0026amp; Logic Connections:\u003c\/strong\u003e Verify proper termination of the 5 Vdc supply line, 24 Vdc power bus, and watchdog signal lines via dedicated distribution boards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Connect the chassis frame directly to the cabinet safety earth bar using approved earthing straps.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVentilation:\u003c\/strong\u003e Maintain unobstructed vertical airflow across all installed card slots to ensure operation within specified thermal limits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 61508 \/ IEC 61511:\u003c\/strong\u003e Functional safety up to SIL 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 61010-1 \/ IEC 61131-2:\u003c\/strong\u003e Safety requirements and equipment specifications for programmable controllers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 61000-6-2 \/ IEC 61326-3-1:\u003c\/strong\u003e Immunity for industrial and safety-related systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 508 \/ UL 508A:\u003c\/strong\u003e Standard for Industrial Control Equipment \/ Industrial Control Panels\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 142:\u003c\/strong\u003e Process Control Equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFM3600 \/ FM 3611:\u003c\/strong\u003e Class I, Division 2, Groups A, B, C \u0026amp; D hazardous location compliance\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667756904811,"sku":"FC-IOCHAS-0001S","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/FS-IOCHAS-0001S_001_1200x1200_e5fbcd8d-9a34-40c5-b657-362718070cbf.jpg?v=1786425574"},{"product_id":"bently-nevada-330180-x1-cn-mod-145004-81-3300-xl-proximitor-sensor","title":"Bently Nevada 330180-X1-CN MOD 145004-81 3300 XL Proximitor Sensor","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330180-X1-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3300 XL Proximitor Sensor from\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003eBently Nevada\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eis a DIN mount signal conditioning module used in 5 mm and 8 mm proximity transducer systems for industrial machinery protection. It processes eddy current probe signals into stable vibration and shaft position outputs for turbines, compressors, generators, and heavy rotating equipment operating in refinery, petrochemical, and power generation environments where continuous condition monitoring is critical to prevent mechanical failure.\u003c\/p\u003e\n\u003cp\u003eThis configuration includes MOD 145004-81 calibration data and is specifically engineered for SNCM 439 target material applications, commonly used in high-strength industrial shaft systems such as Hitachi machinery packages. The DIN rail mounting structure (X1 modification) enables compact installation inside control cabinets, reducing wiring complexity while maintaining stable signal integrity under electrical noise, vibration, and thermal variation.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eSegment\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e330180\u003c\/td\u003e\n\u003ctd\u003e3300 XL Proximitor Sensor base model\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eX1\u003c\/td\u003e\n\u003ctd\u003eDIN rail mounting modification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCN\u003c\/td\u003e\n\u003ctd\u003eCountry specific hazardous area approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMOD 145004-81\u003c\/td\u003e\n\u003ctd\u003eCalibration and configuration dataset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCT-0733\u003c\/td\u003e\n\u003ctd\u003eTarget calibration reference\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJob 162285\u003c\/td\u003e\n\u003ctd\u003eApplication specific configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterial SNCM 439\u003c\/td\u003e\n\u003ctd\u003eTarget shaft material calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemark\u003c\/td\u003e\n\u003ctd\u003eHitachi only application specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe 330180-X1-CN module is designed as part of the 3300 XL proximity measurement chain, interfacing with 5 mm and 8 mm proximity probes and extension cables.\u003c\/p\u003e\n\u003cp\u003eIt performs signal conditioning, demodulation, and linearization of eddy current-based displacement signals. The DIN rail architecture allows direct integration into industrial control cabinets and protection systems, ensuring stable operation in environments with high electromagnetic interference and continuous vibration exposure.\u003c\/p\u003e\n\u003cp\u003eTarget material calibration is critical in this configuration, ensuring accurate measurement response when used with SNCM 439 alloy shafts, commonly found in high-performance rotating machinery.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330180-X1-CN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eU.S.A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eProximitor Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eDIN rail (X1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003eMOD 145004-81\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTarget Material\u003c\/td\u003e\n\u003ctd\u003eSNCM 439\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCT Reference\u003c\/td\u003e\n\u003ctd\u003eCT-0733\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJob Number\u003c\/td\u003e\n\u003ctd\u003e162285\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003e3300 XL 5 mm and 8 mm probes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-51 to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-51 to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e12 to 24 VDC system supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox 0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eMachinery vibration and shaft position monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs 330180-X1-CN compatible with standard 3300 XL probes?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. It is fully compatible with both 5 mm and 8 mm 3300 XL proximity probes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does MOD 145004-81 indicate?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt represents a factory calibration and configuration dataset specific to target material SNCM 439 applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is SNCM 439 material specified?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt ensures accurate calibration for high-strength industrial shaft materials used in heavy machinery systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this module be used in general industrial applications?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt is primarily designed for application-specific systems, especially Hitachi machinery configurations.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation and Engineering Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the module on a properly grounded DIN rail inside a vibration-isolated control cabinet to ensure signal stability.\u003c\/p\u003e\n\u003cp\u003eMaintain strict separation between probe signal wiring and high-power VFD or motor cables to prevent electromagnetic interference.\u003c\/p\u003e\n\u003cp\u003eVerify calibration parameters (MOD 145004-81) before commissioning to ensure correct target material response.\u003c\/p\u003e\n\u003cp\u003eEnsure cabinet thermal management keeps operating conditions within specified limits to avoid signal drift.\u003c\/p\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668317925739,"sku":"145004-81","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/mod145004-81-nsngaptzanv_c2e44692-f942-4f9e-8780-32b8a44ba1d4.jpg?v=1765521087"},{"product_id":"bently-nevada-330195-02-12-10-cn-3300-xl-8-mm-extended-temperature-range-etr-reverse-mount-probe","title":"Bently Nevada 330195-02-12-10-CN 3300 XL 8 mm Extended Temperature Range (ETR) Reverse Mount Probe","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada 330195-02-12-10-CN is a specialized 8 mm eddy current proximity probe part of the 3300 XL Extended Temperature Range (ETR) series. This transducer is specifically engineered for reverse mount applications where the probe must be installed from the interior of a machine housing or through a probe sleeve. The ETR version is rated for significantly higher operating temperatures than standard probes, making it the primary choice for monitoring radial vibration and axial position in steam turbines, gas turbines, and other high-heat rotating machinery.\u003c\/p\u003e\n\u003cp\u003eThis specific model features a 3\/8-24 UNF thread and is configured with a 1.0-metre (3.3 feet) total cable length. The \"CN\" suffix denotes compliance with country-specific hazardous area certifications, including NEPSI approvals for the Chinese market. When integrated with a 3300 XL ETR extension cable and Proximitor sensor, the system delivers a stable linear scale factor of 7.87 V\/mm (200 mV\/mil) even under extreme thermal cycling conditions.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330195-02-12-10-CN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 mm ETR Reverse Mount Proximity Probe\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 XL\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eReverse Mount\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eThread Size\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3\/8-24 UNF\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal Cable Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.0 Metre (3.3 feet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMiniature coaxial ClickLoc™\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAgency Approval\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCN (NEPSI \/ China Specific)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-35°C to +260°C (-31°F to +500°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eScale Factor\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.87 V\/mm (200 mV\/mil)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMade in U.S.A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.323 Kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eReverse mount probes are distinct from standard mount probes in their mechanical housing. Ensure the part number matches the internal machine clearances and the corresponding Proximitor sensor calibration.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e330195\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 XL 8 mm ETR Reverse Mount Probe, 3\/8-24 UNF thread\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-02\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProbe Option: 8 mm ETR Probe\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-12\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eConnector and Cable Option: Miniature coaxial ClickLoc connector, standard cable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-10\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTotal Length Option: 1.0 metre (3.3 feet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-CN\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAgency Approval Option: NEPSI \/ China specific approvals\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Notes\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eReverse Mount Considerations:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUnlike standard probes, the 330195 series is designed to be threaded into a housing from the \"back.\" This is typically required when using Bently Nevada probe housing assemblies or when internal machine space prevents standard front-side access. Ensure that the internal cable routing does not exceed the minimum bend radius of 25.4 mm (1.0 in) to prevent coaxial signal degradation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Expansion Management:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Extended Temperature Range (ETR) probes are designed for environments up to 260°C (500°F). When gapping the probe at ambient temperature, engineers must account for the thermal expansion of the machine shaft and housing. Failure to calculate the \"hot gap\" can result in the probe tip making contact with the shaft (rubbing) or moving out of the linear range during operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Integrity in High-Heat Zones:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 1.0-metre integral cable is rated for the same temperature as the probe tip. However, where the cable exits the high-temperature zone and connects to the extension cable, the ClickLoc™ junction should be housed in a dry, protected location. Use of silicone connector protectors is mandatory in oil-mist environments to prevent fluid \"wicking\" into the coaxial core, which causes signal drift.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding \u0026amp; Shielding:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMaintain a single-point ground. The coaxial shield should be grounded only at the Proximitor end (usually at the monitor rack). In high-interference environments typical of gas turbine halls, ensure the extension cable is routed through a dedicated, grounded conduit to maintain a high signal-to-noise ratio.\u003c\/p\u003e\n\u003ch3\u003eTroubleshooting FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I use a standard 3300 XL extension cable with this ETR probe?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: While they are physically compatible, for maximum accuracy at high temperatures, you must use a 3300 XL ETR extension cable. Standard cables may not withstand the heat or provide the necessary temperature compensation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How do I verify the gapping on a reverse-mount probe?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Use a digital voltmeter at the Proximitor output terminals. For a 3300 XL system, the mid-range gap is typically reached at -10.0 Vdc. Adjust the probe position within the reverse mount sleeve until this value is stabilized.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What indicates a temperature-related probe failure?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: If the DC gap voltage drifts significantly as the machine warms up, but the shaft position is known to be stable, the sensing coil or the coaxial junction may be failing due to thermal stress.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between standard \"02\" and \"CN\" approvals?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Functionally, the probes are identical. The \"CN\" version is specifically labeled and documented to meet the regulatory import and safety requirements of the People's Republic of China (NEPSI).\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668318286187,"sku":"330195-02-12-10-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330195-02-12-10-cn-3pymyxlta3z_2a284877-f821-4717-b103-ab6887ce96a3.jpg?v=1765521099"},{"product_id":"bently-nevada-330101-00-25-10-02-cn-3300-xl-8-mm-proximity-probe","title":"Bently Nevada 330101-00-25-10-02-CN 3300 XL 8 mm Proximity Probe","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada 330101-00-25-10-02-CN is a high-precision 8 mm eddy current proximity probe, a core component of the 3300 XL Transducer System. This system is designed for non-contacting displacement measurements on critical rotating machinery, providing vital data for vibration monitoring, radial position, and axial thrust analysis. It is fully compliant with API 670 standards for machinery protection.\u003c\/p\u003e\n\u003cp\u003eThis specific configuration features a 3\/8-24 UNF thread, a 2.5-inch overall case length, and is supplied without stainless steel armor. The assembly includes a 1.0-metre (3.3 feet) integral cable terminated with a miniature coaxial ClickLoc connector. The \"CN\" suffix denotes country-specific agency approvals, primarily NEPSI, for hazardous area installations within the People's Republic of China. When integrated into a complete loop with a 3300 XL extension cable and Proximitor sensor, it delivers a linear scale factor of 7.87 V\/mm (200 mV\/mil).\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330101-00-25-10-02-CN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 XL 8 mm Proximity Probe\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 XL\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eThread Size\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3\/8-24 UNF\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eUnthreaded Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.0 in\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOverall Case Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.5 in\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal Cable Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.0 Metre (3.3 feet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMiniature coaxial ClickLoc\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eArmor Option\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWithout Armor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAgency Approval\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCN (NEPSI \/ China Specific)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-35°C to +177°C (-31°F to +350°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePressure Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFully sealed tip; resistant to water and oil\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMade in U.S.A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eAccurate identification of the probe configuration is essential for system compatibility. The part number 330101-00-25-10-02-CN is derived from the following option codes:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e330101\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBase Model\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 XL 8 mm Probe, 3\/8-24 UNF thread, without armor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-00\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnthreaded Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.0 in\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-25\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOverall Case Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.5 in\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-10\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTotal Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.0 Metre (3.3 feet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-02\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eConnector\/Cable Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eClickLoc connector, standard cable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-CN\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAgency Approval\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNEPSI \/ China specific approvals\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eLoop Calibration and Total Length:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 3300 XL 8 mm probe is an inductive component within a tuned resonant circuit. This 1.0-metre probe must be paired with an extension cable to reach the required total system length (typically 5.0 or 9.0 metres) as calibrated for the Proximitor sensor. Using a mismatched total loop length will cause significant scale factor errors and zero-point drift.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Mounting Clearances:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTo ensure a linear output and prevent \"side-view\" interference, a minimum side clearance of 13 mm (0.5 in) from metallic surfaces must be maintained around the probe tip. If installing through a mounting bracket, ensure the bracket is rigid enough to avoid resonance frequencies within the machine's operating range.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGap Setting and Voltage:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe probe should be gapped at the electrical center of its linear range. For a 3300 XL system, the nominal mid-range gap is 1.27 mm (50 mils), which typically corresponds to a DC voltage output of -10.0 Vdc at the Proximitor sensor's \"OUT\" terminal.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Protection:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe ClickLoc coaxial connector is sensitive to moisture and lubricant ingress. In oil-mist environments (common in bearing housings), it is mandatory to use the connector protector or oil-resistant heat-shrink tubing to prevent signal \"spiking\" or low insulation resistance faults.\u003c\/p\u003e\n\u003ch3\u003eMaintenance \u0026amp; Troubleshooting FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this probe be used with a legacy (non-XL) 3300 Proximitor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: While physically compatible, the 3300 XL series has a different temperature compensation profile and scale factor stability. For maximum accuracy and API 670 compliance, always match 3300 XL probes with 3300 XL Proximitors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What indicates a faulty ClickLoc connection?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: High-frequency noise or intermittent \"Not OK\" status in the vibration monitor often indicates a loose or contaminated coaxial connection. Inspect the center pin for continuity and ensure the junction is dry.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How do I handle a \"Material Error\"?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Standard probes are calibrated for AISI 4140 steel targets. If the target shaft is a different alloy, the scale factor (V\/mm) will change. This requires a software-based scale factor adjustment or a Material Correction Factor (MCF).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the \"CN\" approval functionally different from standard approvals?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. The \"CN\" suffix ensures the unit carries the NEPSI markings required by Chinese regulatory authorities for explosive atmospheres. The electrical and mechanical performance remains identical to standard 3300 XL probes.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668318318955,"sku":"330101-00-25-10-02-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330101-00-25-10-02-cn-o15jtrnz0a3_50ae2112-bc75-415e-a02b-019f51b4dc81.jpg?v=1765521100"},{"product_id":"bently-nevada-330101-00-25-10-02-00-3300-xl-8-mm-proximity-probes-metric","title":"Bently Nevada 330101-00-25-10-02-00 | 3300 XL 8 mm Proximity Probes, Metric","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada 330101-00-25-10-02-00 is an 8 mm eddy current proximity probe belonging to the 3300 XL series. This transducer is designed for non-contacting displacement and vibration measurements in critical machinery protection systems (TSI). It is a standard component of the 3300 XL Proximity Transducer System, used to monitor radial shaft vibration, axial position, and speed on high-speed rotating equipment such as steam turbines, centrifugal compressors, and motors.\u003c\/p\u003e\n\u003cp\u003eThis specific configuration utilizes a 3\/8-24 UNF thread with a 2.5-inch overall case length and is supplied without stainless steel armor. The assembly features a 1.0-metre (3.3 feet) integral cable terminated with a miniature coaxial ClickLoc™ connector. It provides a linear range of 2.0 mm (80 mils) and a standard scale factor of 7.87 V\/mm (200 mV\/mil) when paired with the corresponding 3300 XL Proximitor sensor and extension cable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330101-00-25-10-02-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 mm Proximity Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300 XL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThread Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/8-24 UNF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnthreaded Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Case Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Cable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.0 Metre (3.3 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc™\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArmor Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout Armor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAgency Approval\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNot Required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-35°C to +177°C (-31°F to +350°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMade in U.S.A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eThis assembly is defined by its alphanumeric suffix codes. Procurement and engineering teams must verify all parameters to ensure mechanical fit and electrical compatibility with the system loop.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e330101\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm Probe, 3\/8-24 UNF thread, without armor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnthreaded Length: 0.0 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-25\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOverall Case Length: 2.5 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-10\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTotal Length: 1.0 Metre (3.3 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-02\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc™ connector, standard cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAgency Approval: Not required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Loop Integrity:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 3300 XL 8 mm probe is a component of a tuned resonant circuit. This 1.0-metre probe must be paired with an extension cable to reach the required total system length (typically 5.0 or 9.0 metres) as calibrated for the Proximitor sensor. Using a mismatched total length will cause significant scale factor errors and non-linearity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Installation:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen installing the 3\/8-24 UNF threads, do not exceed the maximum torque of 13.5 N·m (120 in·lb). Over-torquing can lead to case distortion or internal sensing coil damage. For radial vibration monitoring, ensure the probe tip has a minimum side clearance of 13 mm (0.5 in) from surrounding metallic surfaces to prevent signal interference.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eField Wiring and Grounding:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe ClickLoc™ connector must be kept clean and dry. In oil-mist environments, it is mandatory to use a connector protector or silicone heat-shrink tubing to prevent lubricant ingress. The coaxial cable shield should be grounded only at the monitor\/Proximitor end to prevent ground loops that introduce 50\/60 Hz noise into the signal.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReplacement Precautions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen replacing legacy 3300 probes (non-XL) with 3300 XL series probes, verify the Proximitor sensor is also upgraded to the 3300 XL series. While physically compatible, the XL series has a different temperature compensation profile and scale factor stability.\u003c\/p\u003e\n\u003ch3\u003eMaintenance \u0026amp; Troubleshooting FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this 1.0m probe be used as a standalone sensor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. A 1.0-metre probe is designed to connect to an extension cable. The Proximitor sensor requires the total loop impedance of the specified system length (5m or 9m) to function.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What indicates a faulty ClickLoc connection?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: High-frequency \"spiking\" or an unstable DC gap voltage typically indicates a loose or contaminated coaxial connection. Clean the contacts with an approved electronic cleaner and ensure the connector is dry.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How do I verify the DC gap voltage for a 3300 XL system?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: For most applications, the nominal mid-range gap is 1.27 mm (50 mils), which corresponds to approximately -10.0 Vdc at the Proximitor output terminal.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the impact of target material on calibration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Standard probes are calibrated for AISI 4140 steel. If the target shaft is a different alloy, the scale factor will change, requiring a Material Correction Factor (MCF) adjustment in the monitoring software.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668318351723,"sku":"330101-00-25-10-02-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330101-00-25-10-02-00-kyxwvwtr0nr_268b1358-092e-4668-9dad-d1768226f631.jpg?v=1765521102"},{"product_id":"bently-nevada-330173-00-03-10-02-cn-3300-5mm-proximity-transducer","title":"Bently Nevada 330173-00-03-10-02-CN 3300 5mm Proximity Transducer","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada 330173-00-03-10-02-CN is a 5mm eddy current proximity transducer belonging to the 3300 series. This transducer is specifically engineered for applications where physical space constraints prevent the use of standard 8mm probes. It is primarily utilized in the monitoring of fluid-film bearing machines, including small turbines, compressors, and pumps, to measure radial vibration, axial thrust, and eccentricity.\u003c\/p\u003e\n\u003cp\u003eThe 5mm system is designed to provide a standard scale factor of 7.87 V\/mm (200 mV\/mil) when paired with a compatible 3300 XL Proximitor sensor and extension cable. This specific configuration features an M8 x 1 metric thread, a 30mm overall case length, and a 1.0-metre total cable length. The \"CN\" designation indicates compliance with country-specific hazardous area certifications, including NEPSI approvals for the Chinese market. It utilizes the Miniature coaxial ClickLoc™ connector to ensure signal stability in high-vibration environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330173-00-03-10-02-CN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5mm Proximity Transducer\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eThread Size\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eM8 x 1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eUnthreaded Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOverall Case Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e30 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal Cable Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.0 Metre (3.3 feet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMiniature coaxial ClickLoc™\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAgency Approvals\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCN (NEPSI \/ Hazardous Area)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-35°C to +177°C (-31°F to +350°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePressure Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e70 psi (4.8 bar)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMade in U.S.A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eThe part number is defined by specific mechanical and electrical options. Procurement must ensure suffix compatibility with the installed Proximitor and machine casing depth.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eOption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e330173\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBase Model\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 5mm Transducer, M8 x 1 thread\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-00\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnthreaded Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-03\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCase Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e30 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-10\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTotal Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.0 Metre (3.3 feet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-02\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eConnector\/Cable\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eClickLoc connector, standard cable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-CN\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAgency Approval\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eChina specific approvals (NEPSI)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eMounting and Clearance:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDue to the 5mm tip diameter, this transducer has a smaller linear range than 8mm probes. Maintain a minimum side clearance of 7.6 mm (0.3 in) from surrounding metallic surfaces to prevent signal distortion. When installing in an M8 x 1 tapped hole, do not exceed the maximum torque of 4.5 N·m (40 in·lb) to avoid damaging the sensor tip or the internal sensing coil.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCalibration and Loop Length:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 330173-00-03-10-02-CN is a 1.0-metre transducer. It must be paired with an extension cable (e.g., 4.0m or 8.0m) to reach the required total system length (5m or 9m) as specified by the Proximitor sensor. Using a mismatched total loop length will cause significant errors in the scale factor and DC gap voltage readings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding and Shielding:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eProper signal integrity relies on the coaxial cable shield being grounded at the monitor end only. Ensure the probe body is electrically bonded to the machine casing but that the cable shield remains isolated at the transducer end to prevent ground loops. In high-EMI environments, ensure the extension cable is routed through a dedicated grounded conduit.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConnector Care:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe ClickLoc™ connector must be kept clean and dry. In oil-mist environments, it is mandatory to use the connector protector or silicone heat-shrink tubing to prevent lubricant ingress into the coaxial junction, which can lead to signal \"spiking\" or false trips.\u003c\/p\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can a 3300 5mm transducer be used with a 3300 XL Proximitor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes, provided the Proximitor is specifically calibrated for the 5mm probe. Using a Proximitor calibrated for an 8mm probe will result in incorrect vibration data.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the significance of the \"CN\" approval?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The \"CN\" suffix confirms that the product meets the legal regulatory requirements for hazardous area installations within China (NEPSI). It is functionally identical to the standard version but includes specific labeling and documentation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How do I handle unstable DC gap voltages during commissioning?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: This often indicates a loose ClickLoc connector or a damaged cable. Check for continuity and ensure the connector is dry. Also, verify that the target material is AISI 4140 steel, as other alloys will shift the DC gap curve.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668318384491,"sku":"330173-00-03-10-02-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330173-00-03-10-02-cn-tc1uqcz4gqo_e88bdad5-ee2f-4651-a1f9-0a133e3fa7f0.jpg?v=1765521103"},{"product_id":"bently-nevada-330103-00-03-10-02-cn-3300-xl-proximity-probe","title":"Bently Nevada 330103-00-03-10-02-CN 3300 XL Proximity Probe","description":"\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada 330103-00-03-10-02-CN is an 8 mm eddy current proximity probe part of the 3300 XL series. This transducer is engineered for non-contacting displacement and vibration measurements in critical machinery applications, including steam and gas turbines, centrifugal compressors, and industrial pumps. The 3300 XL system provides an advanced scale factor of 7.87 V\/mm (200 mV\/mil), offering high-fidelity data for radial vibration, axial position, and speed measurements.\u003c\/p\u003e\n\u003cp\u003eThis specific configuration features a 3\/8-24 UNF thread with a 0.3-inch overall case length and is supplied without stainless steel armor. The assembly includes a 1.0-metre (3.3 feet) integral cable terminated with a miniature coaxial ClickLoc™ connector. The \"CN\" suffix indicates compliance with country-specific hazardous area certifications, including NEPSI approvals for the Chinese market. It is designed to operate within the 3300 XL Proximitor® sensor loop for reliable machinery protection and diagnostic monitoring.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330103-00-03-10-02-CN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProximity Probes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 XL\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eThread Size\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3\/8-24 UNF\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eUnthreaded Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.0 in\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOverall Case Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.3 in\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal Cable Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.0 Metre (3.3 feet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMiniature coaxial ClickLoc™\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eArmor Option\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWithout Armor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAgency Approval\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCN (Country Specific \/ NEPSI)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-35°C to +177°C (-31°F to +350°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMade in U.S.A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eThis assembly is defined by its alphanumeric suffix codes. Procurement and engineering teams must verify all parameters to ensure mechanical fit and electrical compatibility with the system loop.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e330103\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 XL 8 mm Probe, 3\/8-24 UNF thread, without armor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-00\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnthreaded Length: 0 in\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-03\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOverall Case Length: 0.3 in\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-10\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTotal Length: 1.0 Metre (3.3 feet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-02\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMiniature coaxial ClickLoc connector, standard cable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-CN\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAgency Approval: Country specific (e.g., NEPSI)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Mounting and Clearance:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 330103 probe must be mounted in a rigid bracket to prevent false vibration readings caused by bracket resonance. Ensure a minimum side clearance of 13 mm (0.5 in) from metallic surfaces surrounding the probe tip to maintain the 7.87 V\/mm scale factor. When installing the 0.3-inch case, use a torque wrench to ensure the 3\/8-24 UNF threads do not exceed 13.5 N·m (120 in·lb) to prevent case distortion.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLoop Calibration:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 3300 XL 8 mm probe is a component of a tuned resonant circuit. This 1.0-metre probe must be paired with the correct length of extension cable (e.g., 4.0 m or 8.0 m) to reach the required 5.0-metre or 9.0-metre total system length calibrated for the Proximitor® sensor. Deviation from the specified total length will result in significant sensitivity errors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eField Wiring and Shielding:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe coaxial ClickLoc™ connector must be protected from environmental contamination. For internal machine applications, use oil-resistant heat-shrink tubing or connector protectors to prevent moisture and lubricant ingress. The shield of the extension cable must be grounded at the monitor end only to prevent ground loops that introduce 50\/60 Hz noise into the vibration signal.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTarget Material Requirements:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eStandard calibration is performed using AISI 4140 steel. If the target shaft is composed of different materials (e.g., stainless steel or chrome-plated shafting), a Scale Factor Error will occur. Technical staff must apply a Material Correction Factor within the monitoring system configuration to ensure accurate displacement readings.\u003c\/p\u003e\n\u003ch3\u003eMaintenance \u0026amp; Troubleshooting FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this 1.0m probe be used as a standalone sensor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. A 1.0-metre probe must be connected to an extension cable. The Proximitor® requires a specific total loop impedance (5m or 9m) to maintain its linear output.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What indicates a faulty ClickLoc connection?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Signal \"spiking\" or high-frequency noise in the monitor usually indicates a loose or contaminated coaxial connection. Inspect the center pin for continuity and ensure the connector is dry and free of metallic debris.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How do I verify the DC gap voltage?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: For a 3300 XL system, the nominal mid-range gap voltage is -10.0 Vdc. Use a voltmeter at the Proximitor terminals during installation to set the physical gap until this voltage is achieved.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is this probe compatible with older 3300 series monitors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes, 3300 XL probes are generally backward compatible with 3300 systems, but it is recommended to use 3300 XL Proximitor sensors to take full advantage of the improved scale factor and temperature stability.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668318417259,"sku":"330103-00-03-10-02-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330103-00-10-10-02-cn-extension-cable-gcvwrdoz53m_77ce8065-4b50-4c36-b5ba-03af14d6511e.jpg?v=1765449495"},{"product_id":"bently-nevada-21000-28-05-00-047-04-02-proximity-probe-housing-assembly","title":"Bently Nevada 21000-28-05-00-047-04-02 Proximity Probe Housing Assembly","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada 21000-28-05-00-047-04-02 is an external mounting Proximity Probe Housing Assembly designed to facilitate the installation of proximity transducers through machine casings. It is a primary component for Turbine Supervisory Instrumentation (TSI) systems, allowing for the adjustment or replacement of probes without disassembling the machine. The assembly provides environmental protection for the probe and maintains a seal against machine internal pressure.\u003c\/p\u003e\n\u003cp\u003eThis specific 21000 series configuration includes an integrated 3300 XL 8 mm proximity probe with multiple agency approvals and a 0.5-metre (20 in) integral cable. The housing is specified with a 4.7-inch probe penetration depth and a 3\/4-14 NPT mounting thread. It is commonly utilized in power generation and petrochemical industries for monitoring radial vibration and axial thrust on steam turbines, compressors, and large gearboxes where external accessibility to the transducer is required.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e21000-28-05-00-047-04-02\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProximity Probe Housing Assemblies\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProbe Option\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 XL 8 mm (Multiple Approvals)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProbe Cable Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 Metre (20 in)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStandoff Adapter\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e00 (None)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProbe Penetration\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.7 Inches (Code 047)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFittings Option\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOne 3\/4-14 NPT plug only\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting Thread\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3\/4-14 NPT\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAluminum (Standard) or Stainless Steel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-35°C to +177°C (-31°F to +350°F) for Probe\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMade in U.S.A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eThis assembly is configured based on specific application requirements. Ensure the penetration depth and mounting threads match the machine casing specifications.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e21000\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBase Model\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eExternal Mounting Proximity Probe Housing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-28\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProbe Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 XL 8 mm probe, Multiple Approvals\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-05\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCable Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 metre (20 in)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-00\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandoff Adapter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNone\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-047\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePenetration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.7 inches\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-04\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFittings\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOne 3\/4-14 NPT plug only\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-02\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMounting Thread\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3\/4-14 NPT\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Alignment and Gapping:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 21000 housing allows for the probe to be gapped externally. During installation, the probe is threaded into the sleeve until it reaches the target. It must then be backed off to achieve the desired DC gap voltage (typically -10.0 Vdc for 3300 XL systems). Once gapped, the locknut must be secured to prevent the probe from moving due to machine vibration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePressure Sealing:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 3\/4-14 NPT mounting thread must be treated with a high-quality thread sealant to ensure a leak-proof connection with the machine casing. If the machine utilizes high-pressure lubricants or is under vacuum, verify the integrity of the O-rings within the housing assembly during routine maintenance intervals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Protection:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 0.5-metre integral cable is terminated with a miniature coaxial ClickLoc connector. This connector should be housed within the terminal head of the 21000 assembly. Ensure the cable is not pinched when closing the housing cover. Use the provided 3\/4-14 NPT plug for unused conduit entries to maintain the environmental rating of the enclosure.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReplacement Precautions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen replacing a probe within the 21000 housing, ensure the replacement probe matches the \"Total Length\" of the original system (typically 5m or 9m total). This 0.5m probe requires a specific extension cable to reach the Proximitor sensor. Using mismatched lengths will lead to calibration errors in the vibration monitor.\u003c\/p\u003e\n\u003ch3\u003eTroubleshooting FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I change the penetration depth in the field?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. The penetration depth (047 = 4.7 inches) is factory-set based on the internal sleeve and probe length. Attempting to modify this will compromise the mechanical limits and gapping capability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What if oil is leaking from the housing head?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: This indicates a failure of the internal seal or O-ring between the probe sleeve and the housing body. Inspect the O-rings for degradation or hardening and replace them with authentic Bently Nevada seal kits.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How do I identify a grounding issue with the 21000 housing?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: If the vibration signal shows 50\/60 Hz interference, verify that the housing is electrically bonded to the machine casing and that the cable shield is only grounded at the Proximitor\/Rack end to avoid ground loops.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the 3300 XL probe inside the housing replaceable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. The probe is a discrete component (-28 option). However, it is highly recommended to replace the probe with the exact same option code to maintain the hazardous area certifications associated with the assembly.\u003c\/p\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668318450027,"sku":"21000-28-05-00-047-04-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-21000-28-05-00-047-04-02-proximity-probe-housingassemblies-i0wr22qjvp4_c6596c84-1084-4307-9e8a-4ce8b22f459d.jpg?v=1765446987"},{"product_id":"bently-nevada-330904-xx-xx-10-02-cn-158268-00-34-3300-nsv-proximity-probe","title":"Bently Nevada 330904-XX-XX-10-02-CN (158268-00-34) 3300 NSv Proximity Probe","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada 330901-XX-XX-10-02-CN (Engineering Part Number 158268-00-34) is an eddy current proximity transducer belonging to the 3300 NSv series. The NSv (Narrow Side View) system is specifically designed for applications where standard 8 mm probes cannot be used due to physical space constraints or tight mounting clearances. It is predominantly used for vibration and position monitoring on small-diameter shafts or within machinery with restricted internal access, such as centrifugal compressors, high-speed pumps, and aeroderivative turbines.\u003c\/p\u003e\n\u003cp\u003eThis specific model features an M8 x 1 metric thread and is equipped with stainless steel armor for enhanced mechanical protection of the coaxial cable. The 1.0-metre total length assembly is terminated with a miniature coaxial ClickLoc connector. The \"CN\" suffix confirms adherence to country-specific hazardous area approvals, including NEPSI certification for the Chinese market. It provides a linear output when paired with a matched 3300 NSv Proximitor Sensor.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330904-XX-XX-10-02-CN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEngineering Part No.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e158268-00-34\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProximity Probes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 NSv\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eThread Size\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eM8 x 1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eArmor Option\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWith Stainless Steel Armor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal Cable Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.0 Metre (39 in)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMiniature coaxial ClickLoc\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAgency Approval\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCN (NEPSI\/Hazardous Area)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-35°C to +177°C (-31°F to +350°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMade in U.S.A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eIndustrial procurement should reference both the model number and the engineering part number to ensure exact configuration matching.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e330904-XX-XX-10-02-CN\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e158268-00-34\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 NSv Probe, M8 x 1, Armor, 1.0m Length\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eMounting and Clearance Requirements:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 3300 NSv series is designed to reduce the \"side-view\" effect; however, a minimum clearance from surrounding metal is still required to maintain linearity. Ensure the probe tip is not recessed into the mounting bracket. For M8 x 1 threads, the recommended mounting torque is 4.5 N·m (40 in·lb) to prevent case distortion or thread damage.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Protection (Armor):\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis model is supplied with stainless steel armor. The armor protects the coaxial core from abrasion and crushing; however, it is not fluid-tight. In environments with heavy oil or chemical exposure, ensure the armored cable is further protected or routed such that liquids cannot migrate into the ClickLoc connector.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding and Shielding:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eProper signal integrity relies on a single-point ground. The shield of the extension cable should be grounded at the Proximitor end (usually in the monitor rack or local junction box). Ensure the probe armor does not inadvertently ground at the machine casing if the system design requires isolated grounds.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReplacement Precautions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 158268-00-34 is a specific engineering configuration. When replacing an existing probe, verify the unthreaded and overall case length (marked as XX-XX in the ordering string) to ensure the probe tip reaches the target shaft without mechanical interference.\u003c\/p\u003e\n\u003ch3\u003eMaintenance \u0026amp; Troubleshooting FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the 3300 NSv probe be used with a standard 3300 XL Proximitor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. The 3300 NSv probe must be paired with a 3300 NSv Proximitor. The internal sensing coil and frequency response of the NSv series differ from the 3300 XL series, and mixing them will result in significant measurement errors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the purpose of the ClickLoc connector protector?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The protector prevents the miniature coaxial connector from loosening due to machine vibration and prevents environmental contaminants (dust\/oil) from entering the signal path. It should always be installed and seated correctly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How do I handle unstable DC gap voltage?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Unstable gap voltage often indicates a loose connection at the ClickLoc junction or moisture ingress. Disconnect the cable, clean the contacts with an approved electronic cleaner, and dry thoroughly before reconnecting.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the target material calibration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Standard Bently Nevada proximity probes are calibrated for AISI 4140 steel. If the target shaft is a different alloy, the scale factor (V\/mm) will change, requiring a software scale factor adjustment in the monitoring system.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668318482795,"sku":"330904-XX-XX -10-02-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330904-xx-xx-10-02-cn-wqkn2jbrtsd_efaefd85-80ff-4ee4-869a-7091b6f00dca.jpg?v=1765521106"},{"product_id":"bently-nevada-330101-00-24-05-02-00-3300-xl-proximity-probe","title":"Bently Nevada 330101-00-24-05-02-00 3300 XL Proximity Probe","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada 330101-00-24-05-02-00 is a high-precision 8 mm eddy current proximity probe part of the 3300 XL series. This transducer is engineered for non-contacting displacement measurements in critical rotating machinery, providing essential data for vibration monitoring, radial position, and axial thrust analysis. It is compatible with 3300 XL Proximitor Sensors and is widely utilized in the monitoring of steam turbines, centrifugal compressors, and industrial pumps.\u003c\/p\u003e\n\u003cp\u003eThis specific configuration features a 3\/8-24 UNF thread with a 2.4-inch overall case length and is supplied without stainless steel armor. The assembly includes a 0.5-metre (1.6 feet) integral cable terminated with a miniature coaxial ClickLoc connector. Designed to operate under extreme industrial conditions, the probe maintains a linear scale factor of 7.87 V\/mm (200 mV\/mil) when paired with the appropriate 3300 XL extension cable and Proximitor.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330101-00-24-05-02-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProximity Probes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 XL\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProbe Tip Diameter\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eThread Size\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3\/8-24 UNF\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eUnthreaded Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.0 in\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOverall Case Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.4 in\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal Cable Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 Metre (1.6 feet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMiniature coaxial ClickLoc\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eArmor Option\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWithout Armor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAgency Approval\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Required\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMade in U.S.A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-35°C to +177°C (-31°F to +350°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.5 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eAccurate identification of the probe configuration is essential for system compatibility. The part number 330101-00-24-05-02-00 is derived from the following option codes:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e330101\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 XL 8 mm Probe, 3\/8-24 UNF thread, without armor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-00\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnthreaded Length: 0 in\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-24\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOverall Case Length: 2.4 in\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-05\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTotal Length: 0.5 metre (1.6 feet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-02\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMiniature coaxial ClickLoc connector, standard cable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-00\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAgency Approval: Not required\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCalibration and Loop Length:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 3300 XL 8 mm probe is a component of a tuned resonant circuit. This 0.5-metre probe must be used with a 4.5-metre or 8.5-metre extension cable to reach the required 5.0-metre or 9.0-metre total system length. Using a total length that deviates from the Proximitor's calibrated specification will result in an incorrect Scale Factor (SSF) and non-linear output.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Installation:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen installing the 3\/8-24 UNF probe through the machine casing, ensure the mounting bracket is rigid to avoid resonance. Tighten the probe to a maximum torque of 13.5 N·m (120 in·lb). Exceeding this limit can cause case distortion or damage to the internal sensing coil.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGap Setting:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe probe should be gapped at the mechanical center of its linear range. For a 3300 XL system, the nominal mid-range gap is 1.27 mm (50 mils), which typically corresponds to a DC voltage output of -10.0 Vdc from the Proximitor sensor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConnector Protection:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe ClickLoc connector (-02) is designed for secure coupling but remains sensitive to environmental contamination. For internal machine applications, the use of connector protectors or oil-resistant heat-shrink tubing is recommended to prevent moisture or lubricant ingress, which can lead to signal \"spiking\" or drift.\u003c\/p\u003e\n\u003ch3\u003eTroubleshooting FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I use this probe with a standard 3300 (non-XL) Proximitor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: While 3300 XL probes are physically compatible, the 3300 XL system has a different scale factor and temperature compensation profile. For maximum accuracy, it is recommended to use 3300 XL Proximitor sensors with 3300 XL probes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What indicates a faulty ClickLoc connection?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: High-frequency noise or \"spiking\" in the vibration signal often indicates a loose or contaminated coaxial connection. Check the center pin for continuity and ensure the connector is dry.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the 0.5m length sufficient for my installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The 0.5-metre probe is typically used when the connection to the extension cable occurs inside the machine or a nearby junction box. Ensure the total length (probe + extension cable) matches your specific Proximitor model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does this probe require a safety barrier?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Since this model is \"Not Required\" (Option 00) for agency approvals, it does not carry intrinsic safety certifications. If the installation area is classified as hazardous, a probe with the appropriate approval code (e.g., -05 for multi-approvals) must be selected.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668318548331,"sku":"330101-00-24-05-02-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330101-00-24-05-02-00-ajtyggij1xx_d67f1f3a-9448-457d-8f8d-c2fabc603500.jpg?v=1765521108"},{"product_id":"bently-nevada-330101-00-30-05-02-00-3300-xl-proximity-probe","title":"Bently Nevada 330101-00-30-05-02-00 3300 XL Proximity Probe","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada 330101-00-30-05-02-00 is a high-performance 8 mm eddy current proximity probe belonging to the 3300 XL series. This transducer is a primary component for vibration monitoring, radial position, and axial thrust measurement in critical rotating machinery, including steam turbines, centrifugal compressors, and industrial pumps. Utilizing the eddy current principle, it provides a non-contacting method to observe the target shaft's movement relative to the machine housing.\u003c\/p\u003e\n\u003cp\u003eThis specific configuration features a 3\/8-24 UNF thread with a 3.0-inch overall case length and is supplied without stainless steel armor. With a total electrical length of 0.5 metres (1.6 feet), it is intended for internal mounting applications where the probe is installed through a machine casing and connected to an extension cable. The assembly utilizes the ClickLoc miniature coaxial connector, ensuring signal integrity through vibration-resistant coupling.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330101-00-30-05-02-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProximity Probes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 XL\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProbe Tip Diameter\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eThread Size\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3\/8-24 UNF\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eUnthreaded Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.0 in\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOverall Case Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.0 in\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal Cable Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 Metre (1.6 feet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMiniature Coaxial ClickLoc\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eArmor Option\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWithout Armor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAgency Approval\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Required\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMade in U.S.A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-35°C to +177°C (-31°F to +350°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eThis assembly is defined by its alphanumeric suffix codes. Procurement and engineering teams must verify all parameters to ensure mechanical fit and electrical compatibility with the system loop.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e330101\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 XL 8 mm Probe, 3\/8-24 UNF thread, without armor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-00\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnthreaded Length: 0.0 in\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-30\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOverall Case Length: 3.0 in\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-05\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTotal Length: 0.5 metre (1.6 feet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-02\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMiniature coaxial ClickLoc connector, standard cable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-00\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAgency Approval: Not required\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eMounting Clearances:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTo ensure a linear output and prevent \"side-view\" interference, a minimum side clearance of 13 mm (0.5 in) from metallic surfaces must be maintained around the probe tip. If installing multiple probes in a single radial bearing plane, maintain a minimum spacing of 40 mm (1.6 in) between probe centers to avoid crosstalk.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLoop Calibration and Cable Length:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 3300 XL 8 mm probe is part of a tuned system. This 0.5-metre probe must be paired with an extension cable to reach the total system length (typically 5.0 or 9.0 metres) required by the 3300 XL Proximitor Sensor. Using a probe\/cable combination that does not match the Proximitor’s calibrated length will result in significant sensitivity errors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConnector Integrity:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe ClickLoc connector (-02) is designed for reliable signal transmission but is sensitive to environmental contamination. During installation, ensure connectors are free of moisture, oil, and metallic debris. The use of connector protectors or silicone heat-shrink tubing is recommended for internal machine environments to prevent connector loosening due to vibration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Installation:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 3\/8-24 UNF threads should be tightened to a maximum torque of 13.5 N·m (120 in·lb). Over-torquing can lead to case distortion or thread stripping, which may compromise the hermetic seal of the probe tip.\u003c\/p\u003e\n\u003ch3\u003eMaintenance \u0026amp; Troubleshooting FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this 0.5m probe be used as a standalone sensor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. A 0.5-metre probe is designed to be connected to an extension cable. The 3300 XL Proximitor requires a total loop length (e.g., 5m or 9m) to function within its linear range.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What should the DC gap voltage be for a standard installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: For a 3300 XL system, the nominal mid-range gap voltage is typically -10.0 Vdc. Set the physical gap during installation to reach this voltage at the Proximitor output for optimal linear range.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How do I handle a \"Probe Not Found\" or \"Not OK\" status on the monitor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Check the continuity of the center pin on the ClickLoc connector. Ensure the total resistance of the probe (center to outer conductor) is within factory limits (typically 3.0 to 12.0 ohms depending on cable length).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is this probe compatible with the original 3300 system?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: While 3300 XL probes are generally compatible with older 3300 systems, there may be slight differences in the scale factor. It is best practice to use 3300 XL components throughout the entire signal string.\u003c\/p\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668318581099,"sku":"330101-00-30-05-02-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330101-00-30-05-02-00-sqwnomiy32m_03c00db5-4d96-4ac2-82af-7f73900aaa47.jpg?v=1765521109"},{"product_id":"bently-nevada-330901-00-90-10-01-cn-3300-nsv-proximity-probe","title":"Bently Nevada 330901-00-90-10-01-CN 3300 NSv Proximity Probe","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada 330901-00-90-10-01-CN is a high-precision proximity probe belonging to the 3300 NSv (Narrow Side View) series. This transducer system is specifically engineered for applications with tight physical constraints or where the target surface is small, such as centrifugal compressors, pumps, and small turbines. The NSv series is designed to minimize \"side-view\" effects, allowing the probe to be used in proximity to neighboring metallic surfaces that would interfere with standard 8 mm probes.\u003c\/p\u003e\n\u003cp\u003eThis specific model features a 1\/4-28 UNF thread and is configured with a 9.0-inch overall case length and a 1.0-metre total length. It is supplied without stainless steel armor on the cable and includes a miniature coaxial ClickLoc connector with a connector protector. The \"CN\" suffix indicates compliance with ATEX\/IECEx and Chinese NEPSI hazardous area standards, making it suitable for global and domestic Chinese industrial projects.\u003c\/p\u003e\n\u003ch3\u003eHardware Configuration\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330901-00-90-10-01-CN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProximity Probes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 NSv\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eThread Size\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1\/4-28 UNF\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eUnthreaded Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.0 in\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOverall Case Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9.0 in\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal Cable Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.0 Metre (39 in)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMiniature coaxial ClickLoc with protector\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eArmor Option\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWithout Armor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHazardous Area Approvals\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eATEX, IECEx, NEPSI (CN)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-35°C to +177°C (-31°F to +350°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e~150 g (Net) \/ 1.0 kg (Shipping)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eThis part number is generated based on a specific configuration of the 330901 base model. Ensure all suffix codes match existing field documentation before ordering.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e330901\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 NSv Proximity Probe (1\/4-28 UNF thread)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-00\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnthreaded Length: 0.0 in\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-90\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOverall Case Length: 9.0 in\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-10\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTotal Length: 1.0 Metre (39 in)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-01\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMiniature coaxial ClickLoc connector with protector\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-CN\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eATEX\/IECEx and NEPSI hazardous area markings\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInstallation \u0026amp; Engineering Notes\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eTarget Material and Surface Finish:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 3300 NSv system is factory-calibrated for AISI 4140 steel. If the target shaft is made of a different material, the Proximitor sensor output will require recalibration or a scale factor adjustment. The target area should be at least 1.5 times the probe tip diameter (approx. 9.5 mm \/ 0.375 in) to ensure a linear output.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMounting Clearances:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe NSv series is designed for tight spaces; however, a minimum side clearance of 1.5 mm (0.06 in) from the probe tip to surrounding metallic objects must be maintained to prevent signal distortion. When installing the 9.0-inch case, ensure the probe is not over-torqued into the mounting bracket; recommended torque for 1\/4-28 UNF threads is 2.3 N·m (20 in·lb).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Protection and Routing:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis model (-01) is supplied without armor. In environments with high mechanical risk or chemical exposure, the cable should be protected using a dedicated flexible conduit. All coaxial connections must be kept clean and dry. The ClickLoc connector protector must be properly seated to maintain signal integrity and prevent environmental contamination.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHazardous Area Compliance:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \"CN\" approval code is mandatory for installations within the People's Republic of China requiring NEPSI certification. For global projects, the ATEX and IECEx markings ensure the probe can be used in intrinsically safe (IS) circuits when paired with an approved Proximitor sensor and safety barrier.\u003c\/p\u003e\n\u003ch3\u003eTroubleshooting FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can a 3300 NSv probe be used with a standard 3300 XL Proximitor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. 3300 NSv probes require a dedicated 3300 NSv Proximitor sensor. Using a standard 3300 XL Proximitor will result in incorrect sensitivity and non-linear data.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the maximum recommended distance between the probe and Proximitor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The total length of the probe plus the extension cable must match the Proximitor sensor’s design (typically 5.0 or 7.0 metres). This specific probe is 1.0 metre; thus, a 4.0 or 6.0 metre extension cable is required.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How do I identify a faulty ClickLoc connector?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: If the vibration signal shows high-frequency \"spiking\" or the DC gap voltage is unstable, inspect the miniature coaxial center pin. Ensure the connector protector is not cracked and that no moisture has entered the junction.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668318613867,"sku":"330901-00-90-10-01-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330901-00-90-10-01-cn-mir0klbszv1_82935524-d760-4f38-a316-3ff7fe45160e.jpg?v=1765521111"},{"product_id":"bently-nevada-24701-28-05-xx-028-04-xx-mod-323933-00-02-proximity-probe-housing-assembly","title":"Bently Nevada 24701-28-05-XX-028-04-XX MOD 323933-00-02 Proximity Probe Housing Assembly","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada 24701-28-05-XX-028-04-XX MOD 323933-00-02 is a specialized Proximity Probe Housing Assembly designed for internal mounting applications within the 3300 XL series vibration monitoring systems. This assembly facilitates the secure installation and environmental protection of an 8 mm proximity probe through the machine casing.\u003c\/p\u003e\n\u003cp\u003eConstructed with a 303 stainless steel body and a 304 stainless steel sleeve, the housing is engineered to withstand high-pressure lubricants and corrosive atmospheres common in steam turbines, centrifugal compressors, and industrial gearboxes. This specific configuration includes a 3300 XL 8 mm probe with multiple hazardous area approvals, a 0.5-metre integral cable, and a 2.8-inch probe penetration depth. The \"MOD\" suffix indicates a custom factory modification (323933-00-02) tailored to specific OEM or end-user engineering requirements, ensuring precise alignment with machine internal clearances.\u003c\/p\u003e\n\u003ch3\u003eHardware Configuration\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24701-28-05-XX-028-04-XX MOD 323933-00-02\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProximity Probe Housing Assemblies\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 XL\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBody Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e303 Stainless Steel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSleeve Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e304 Stainless Steel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProbe Option\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 XL 8 mm (Multiple Approvals)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProbe Cable Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 Metre (20 in)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProbe Penetration\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.8 inch\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStandoff Adapter\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNone\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFittings Option\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOne 3\/4-14 NPT plug only\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModification Info\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMOD 323933-00-02\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.8 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eThis assembly is configured according to Bently Nevada standard option codes. Procurement should verify all suffix segments to ensure mechanical compatibility.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e24701\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProximity Probe Housing Assembly Base Model\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-28\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 XL 8 mm probe with connector and multiple approvals\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-05\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 metre (20 in) probe cable length\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-XX\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo standoff adapter required\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-028\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.8 inch probe penetration depth\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-04\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOne 3\/4-14 NPT plug\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-XX\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo additional options\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMOD 323933-00-02\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFactory Modified Specification\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eProbe Penetration and Air Gap Setting:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 2.8-inch penetration depth must be verified against the machine casing thickness and the required standoff from the shaft. Precise air gap adjustment is critical for the linear range of the 3300 XL system. Use a calibrated voltmeter to set the gap voltage (typically -10.0 Vdc for a mid-range gap) before final torquing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSealing and Pressure Integrity:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 24701 housing is designed to maintain a seal against machine internal pressure. Ensure the NPT threads are treated with appropriate industrial-grade sealant (e.g., Loctite 567 or equivalent) to prevent oil leakage. Avoid over-torquing the probe within the sleeve, as this can damage the probe tip or the internal threading.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Protection:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 0.5-metre cable segment is susceptible to mechanical damage during installation. All internal wiring should be secured using stainless steel clips to prevent cable whip or fatigue caused by machine vibration. Use flexible conduit for the external portion of the cable run to the Proximitor Sensor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReplacement Precautions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen replacing an existing housing, ensure the MOD 323933-00-02 specification matches the original installation. Standard 24701 units may lack the specific internal clearances or thread modifications present in this MOD version, potentially leading to mechanical interference or seal failure.\u003c\/p\u003e\n\u003ch3\u003eTroubleshooting FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can a standard 3300 XL probe be used as a replacement within this housing?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: While the housing accepts 8 mm probes, the specific probe in this assembly (-28 option) includes multiple approvals and a specialized connector. Always match the probe part number found on the cable tag to ensure electrical compatibility with the Proximitor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How do I identify the specific modification in MOD 323933-00-02?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: MOD numbers are internal factory records. This modification typically involves non-standard sleeve lengths, specialized thread pitches, or unique material treatments. Refer to your original machine OEM manual or Bently Nevada data sheet for this MOD code.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the significance of the 3\/4-14 NPT plug?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Option -04 provides one plug for unused conduit entries in the housing head. Ensure this is installed and tightened to maintain the IP\/NEMA rating of the assembly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is this housing suitable for high-temperature service?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The stainless steel construction is rated for high temperatures, but the limit is governed by the 3300 XL probe's specifications. Generally, the probe is rated up to 177°C (350°F).\u003c\/p\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668318646635,"sku":"323933-00-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/24701-28-05-xx-028-04-xx-mod-323933-00-02-31epxd14pkj_14a9666f-18b1-4087-9b4b-e8db977d8eb0.jpg?v=1765521111"},{"product_id":"330877-080-36-cn-bently-nevada-3300-xl-50-mm-extension-cable","title":"330877-080-36-CN Bently Nevada 3300 XL 50 mm Extension Cable","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330877-080-36-CN (330877-080-36-CN)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance 3300 XL 50 mm extension cable manufactured by Bently Nevada, specifically engineered for critical machinery protection and proximity sensor systems. As a vital component of the 3300 XL 50 mm Proximitor sensor system, this cable maintains signal integrity between the probe and the Proximitor sensor in large-scale rotating equipment. Featuring the specialized FluidLoc technology and PFA insulation, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330877-080-36-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed to prevent hazardous fluids from wicking through the cable, making it an essential solution for oil-filled environments such as turbines, compressors, and large industrial pumps in the oil and gas or power generation sectors.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330877-080-36-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eutilizes a 75 ohm triaxial architecture, insulated with perfluoroalkoxyethylene (PFA) to ensure extreme temperature resilience and chemical resistance. This specific configuration features a cable length of 8.0 meters (26.2 feet) and utilizes the \"36\" FluidLoc option, which provides an additional layer of protection against fluid migration—a common cause of sensor failure in pressurized machinery. The \"CN\" agency approval indicates country-specific compliance, ensuring the hardware meets rigorous safety and technical standards for localized industrial deployments. With a typical capacitance of 69.9 pF\/m, the cable is tuned to maintain the precise electrical characteristics required for accurate vibration and position measurements.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330877-080-36-CN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMade in U.S.A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCable Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 XL 50 mm Extension Cable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8.0 meters (26.2 feet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCable Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e75 ohm triaxial, PFA insulated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eArmor\/Cable Option\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFluidLoc technology (Option 36)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCapacitance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e69.9 pF\/m (Typical)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 to +200 Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 to +200 Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAgency Approval\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCN (Country Specific)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary benefit of the FluidLoc (Option 36) cable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe FluidLoc extension cable is specifically designed with a proprietary internal seal that prevents oil, moisture, or other process fluids from leaking through the inside of the cable. This protects the Proximitor sensor electronics from contamination if a probe seal fails in an oil-filled machine housing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 330877-080-36-CN compatible with standard 3300 XL 8 mm probes?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. This extension cable is specifically designed for the 3300 XL 50 mm system. The electrical characteristics (capacitance and impedance) of 50 mm cables differ from 8 mm or 11 mm systems. Using mismatched cables will result in significant calibration errors and inaccurate machinery vibration data.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this cable withstand extreme high-temperature environments?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Thanks to the PFA (perfluoroalkoxyethylene) insulation, the cable is rated for continuous operation in temperatures ranging from -51 Celsius to +200 Celsius, making it suitable for mounting inside hot turbine enclosures or near steam lines.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnector Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDuring installation, ensure the miniature coaxial connectors remain clean and dry. Use a silicone lubricant only on the connector threads if required by the manual, but never on the signal-carrying pins. It is highly recommended to use connector protectors or heat-shrink tubing to seal the connection point between the probe and the extension cable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bend Radius:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo avoid damaging the triaxial shielding and the FluidLoc seal, observe the minimum bend radius during routing. Avoid sharp 90-degree bends; instead, use sweeping curves to maintain the 75 ohm impedance and prevent signal attenuation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRouting and Interference:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRoute the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330877-080-36-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ethrough grounded metal conduit wherever possible. Avoid running the extension cable parallel to high-voltage AC motor leads or VFD cables, as electromagnetic interference (EMI) can introduce noise into the low-voltage proximity signal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668318679403,"sku":"330877-080-36-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330877-080-36-cn-aqxqi3pbqbs_b6b0a565-3d1e-4920-94a6-c1ddfde9ed58.jpg?v=1765521112"},{"product_id":"bently-nevada-3500-15-05-05-cn-3500-15-dual-channel-power-supply-module","title":"Bently Nevada 3500\/15-05-05-CN 3500\/15 Dual Channel Power Supply Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 3500\/15-05-05-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a 3500 Series rack power supply module designed to provide regulated and reliable electrical power for Bently Nevada 3500 machinery protection systems. It is widely used in power plants, oil and gas facilities, and heavy industrial processing units where continuous condition monitoring depends on stable rack-level power delivery.\u003c\/p\u003e\n\u003cp\u003eThis module supports universal AC input and dual-slot redundancy configuration, ensuring uninterrupted operation of critical monitoring systems. The design allows simultaneous installation of two power supplies for redundancy, reducing risk of system shutdown due to single power failure.\u003c\/p\u003e\n\u003cp\u003eThe CN configuration indicates country-specific hazardous area compliance requirements for regulated industrial environments.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003ePower Configuration Structure\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eElement\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e3500\/15\u003c\/td\u003e\n\u003ctd\u003e3500 Series power supply module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003eUniversal AC input 85 to 264 Vac rms (top slot)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003eUniversal AC input 85 to 264 Vac rms (bottom slot)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCN\u003c\/td\u003e\n\u003ctd\u003eCountry-specific approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThis configuration defines input compatibility and redundancy architecture for rack power distribution.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3500\/15-05-05-CN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e25.15 cm x 5.08 cm x 12.07 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eNot specified (typical rack module design approx. 2–3 kg system-level)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e85 to 264 Vac rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-30 deg C to +65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e95 percent non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem\u003c\/td\u003e\n\u003ctd\u003e3500 machinery protection system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs this power supply redundant?\u003c\/strong\u003e\u003cbr\u003eYes. The 3500\/15 supports dual power supply configuration for redundancy.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it operate on global voltage standards?\u003c\/strong\u003e\u003cbr\u003eYes. It supports universal AC input from 85 to 264 Vac.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if one power module fails?\u003c\/strong\u003e\u003cbr\u003eThe system continues operating using the remaining active supply.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this compatible with all 3500 racks?\u003c\/strong\u003e\u003cbr\u003eIt is compatible with standard Bently Nevada 3500 rack systems.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Notes\u003c\/h3\u003e\n\u003cp\u003eInstall both power supplies in dual configuration when system uptime is critical.\u003c\/p\u003e\n\u003cp\u003eEnsure proper rack grounding to reduce electrical noise and improve system stability.\u003c\/p\u003e\n\u003cp\u003eVerify airflow clearance to maintain thermal stability under high load conditions.\u003c\/p\u003e\n\u003cp\u003eDo not mix incompatible power module revisions within the same rack.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eOperational Engineering Guidance\u003c\/h3\u003e\n\u003cp\u003eUse redundant power configuration in turbine protection and compressor monitoring systems.\u003c\/p\u003e\n\u003cp\u003eMaintain stable environmental conditions to extend module lifecycle.\u003c\/p\u003e\n\u003cp\u003eInspect connectors during scheduled maintenance cycles to prevent intermittent power loss.\u003c\/p\u003e\n\u003cp\u003eEnsure correct slot placement to avoid configuration mismatch in rack systems.\u003c\/p\u003e\n\u003ch1\u003e\u003c\/h1\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668318712171,"sku":"3500\/15-05-05-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/350015-05-05-cn-tq34mqb1fs4_b60a0308-d0e3-4021-897f-fc7c07e1ae3d.jpg?v=1765521114"},{"product_id":"bently-nevada-330100-90-00-3300-proximitor-sensor-signal-conditioning-module","title":"Bently Nevada 330100-90-00 3300 Proximitor Sensor Signal Conditioning Module","description":"\n\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 330100-90-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a legacy 3300 series Proximitor Sensor used for vibration and displacement signal conditioning in proximity measurement systems. It is commonly deployed in legacy monitoring architectures across power generation, oil refinery, and heavy industrial rotating equipment where existing 3300 system infrastructure remains in operation.\u003c\/p\u003e\n\u003cp\u003eThis model is part of the original 3300 platform and has been superseded by the 3300 XL series, specifically the 330180-90-00 sensor. It still appears in installed base systems where upgrade cycles have not yet been completed.\u003c\/p\u003e\n\u003cp\u003eThe unit provides stable signal conversion from proximity probes into processed electrical outputs for vibration monitoring systems.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eProduct Status and Replacement Path\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eItem\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOriginal Model\u003c\/td\u003e\n\u003ctd\u003e330100-90-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e3300 Proximitor Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReplacement\u003c\/td\u003e\n\u003ctd\u003e330180-90-00 3300 XL Proximitor Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus\u003c\/td\u003e\n\u003ctd\u003eLegacy \/ Discontinued\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe 3300 XL replacement improves temperature stability, RFI immunity, and long-term signal accuracy.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330100-90-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.29 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003e3300 Proximitor Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e9.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApproval\u003c\/td\u003e\n\u003ctd\u003eMultiple approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem\u003c\/td\u003e\n\u003ctd\u003e3300 proximity monitoring system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs this model still in production?\u003c\/strong\u003e\u003cbr\u003eNo. It is a legacy product replaced by 3300 XL series sensors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the recommended replacement?\u003c\/strong\u003e\u003cbr\u003eThe direct replacement is Bently Nevada 330180-90-00.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it be used with existing 3300 probes?\u003c\/strong\u003e\u003cbr\u003eYes. It is designed for compatibility within 3300 legacy systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs performance better than 3300 XL?\u003c\/strong\u003e\u003cbr\u003eNo. The XL series provides improved accuracy and environmental stability.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Maintenance Notes\u003c\/h3\u003e\n\u003cp\u003eThis sensor is typically found in installed legacy monitoring systems that still operate reliably under industrial conditions.\u003c\/p\u003e\n\u003cp\u003eWhen maintaining existing systems, verify cable integrity and connector condition to avoid signal degradation.\u003c\/p\u003e\n\u003cp\u003eReplacement planning should consider migration to 3300 XL architecture for improved long-term reliability.\u003c\/p\u003e\n\u003cp\u003eEnsure proper grounding to reduce noise in older installations.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eProcurement Guidance\u003c\/h3\u003e\n\u003cp\u003eThis part is typically sourced for system maintenance rather than new installation projects.\u003c\/p\u003e\n\u003cp\u003eVerify compatibility with existing 3300 probe and extension cable configurations before procurement.\u003c\/p\u003e\n\u003cp\u003eFor long-term asset strategy, evaluate transition to 3300 XL platform to reduce lifecycle risk.\u003c\/p\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668318744939,"sku":"330100-90-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330100-90-00-qtgu1fbtb3g_4982d076-6387-4e99-bff3-6c605b2a05e8.jpg?v=1765521115"},{"product_id":"330103-00-07-10-12-cn-bently-nevada-3300-xl-8-mm-proximity-probes","title":"330103-00-07-10-12-CN | Bently Nevada | 3300 XL 8 mm Proximity Probes","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 330103-00-07-10-12-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a 3300 XL 8 mm proximity probe designed for precise vibration and shaft displacement monitoring in critical rotating machinery. It is widely applied in turbines, compressors, and refinery pumps where stable signal integrity directly supports machine protection and predictive maintenance strategies.\u003c\/p\u003e\n\u003cp\u003eThis model integrates FluidLoc cable technology, improving resistance against oil contamination and moisture ingress in industrial environments. The compact 70 mm case length supports installations in restricted mounting zones, while maintaining consistent measurement linearity under continuous operation.\u003c\/p\u003e\n\u003cp\u003eThe ClickLoc connector system ensures stable electrical contact in high-vibration conditions, reducing signal instability caused by mechanical loosening.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eConfiguration Breakdown\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eElement\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e330103\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm probe series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo unthreaded length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e07\u003c\/td\u003e\n\u003ctd\u003e70 mm overall case length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e1.0 m total cable length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003eClickLoc connector with FluidLoc cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCN\u003c\/td\u003e\n\u003ctd\u003eCountry-specific hazardous area approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThis configuration defines probe geometry, sealing technology, cable protection level, and compliance classification.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330103-00-07-10-12-CN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.323 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm proximity probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase Length\u003c\/td\u003e\n\u003ctd\u003e70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Length\u003c\/td\u003e\n\u003ctd\u003e1.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003eFluidLoc sealed cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTip Material\u003c\/td\u003e\n\u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase Material\u003c\/td\u003e\n\u003ctd\u003eAISI 303 \/ 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the advantage of FluidLoc cable?\u003c\/strong\u003e\u003cbr\u003eIt reduces fluid ingress risk and improves reliability in oil-rich environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this probe suitable for turbine applications?\u003c\/strong\u003e\u003cbr\u003eYes. It is commonly used in turbine vibration monitoring systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes CN option affect performance?\u003c\/strong\u003e\u003cbr\u003eNo. It relates to certification and compliance only.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it replace standard 3300 XL probes?\u003c\/strong\u003e\u003cbr\u003eYes, if mechanical and electrical configuration matches system requirements.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Engineering Notes\u003c\/h3\u003e\n\u003cp\u003eMaintain correct probe gap calibration to ensure accurate displacement measurement.\u003c\/p\u003e\n\u003cp\u003eAvoid sharp cable bends near connector to preserve shielding integrity.\u003c\/p\u003e\n\u003cp\u003eRoute cables away from high EMI sources to maintain signal stability.\u003c\/p\u003e\n\u003cp\u003eEnsure secure mounting torque to prevent probe drift under vibration load.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication Engineering Guidance\u003c\/h3\u003e\n\u003cp\u003eFluidLoc cable improves performance in oil mist and moisture-prone environments.\u003c\/p\u003e\n\u003cp\u003eThe 70 mm case design allows installation in compact machine housings.\u003c\/p\u003e\n\u003cp\u003eClickLoc connector enhances field reliability under continuous vibration exposure.\u003c\/p\u003e\n\u003cp\u003eSuitable for continuous monitoring in power generation and process industries.\u003c\/p\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668318777707,"sku":"330103-00-07-10-12-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330103-00-07-10-12-cn-d5i5xv1x14b_aaac396f-a25b-4a3b-970a-454f02c85e64.jpg?v=1765521117"},{"product_id":"bently-nevada-330906-02-12-10-02-cn-3300-nsv-reverse-mount-proximity-probe","title":"Bently Nevada 330906-02-12-10-02-CN 3300 NSv Reverse Mount Proximity Probe","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 330906-02-12-10-02-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a 3300 NSv reverse mount proximity probe designed for vibration and shaft displacement monitoring in compact rotating machinery. It is typically used in auxiliary turbines, compressors, and pump systems where reverse installation geometry is required due to restricted mounting access.\u003c\/p\u003e\n\u003cp\u003eThe reverse mount design allows installation from the opposite direction of standard probe orientation, improving flexibility in dense mechanical assemblies. The NSv architecture maintains stable signal response in constrained environments while preserving compatibility with Bently Nevada monitoring systems.\u003c\/p\u003e\n\u003cp\u003eThe 1.0 meter cable configuration supports standard routing in industrial control layouts with moderate distance between probe and monitoring module.\u003c\/p\u003e\n\u003cp\u003eCN approval configuration supports deployment in regulated hazardous environments with regional certification requirements.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eConfiguration Breakdown\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eElement\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e330906\u003c\/td\u003e\n\u003ctd\u003e3300 NSv reverse mount probe series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eConnector\/cable configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003eMechanical case and mounting configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e1.0 m total cable length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eClickLoc connector, standard cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCN\u003c\/td\u003e\n\u003ctd\u003eCountry-specific hazardous area approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThis structure defines mounting direction, installation geometry, cable length, and compliance classification.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330906-02-12-10-02-CN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003e3300 NSv reverse mount proximity probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Length\u003c\/td\u003e\n\u003ctd\u003e1.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eShaft vibration and position monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Style\u003c\/td\u003e\n\u003ctd\u003eReverse mount configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApproval\u003c\/td\u003e\n\u003ctd\u003eCN hazardous area certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is a reverse mount probe used for?\u003c\/strong\u003e\u003cbr\u003eIt is used when standard probe access is blocked or limited by machine structure.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it compatible with standard NSv systems?\u003c\/strong\u003e\u003cbr\u003eYes. It follows NSv electrical and mechanical interface standards.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes reverse mounting affect signal accuracy?\u003c\/strong\u003e\u003cbr\u003eNo. Measurement performance remains unchanged if installation gap is correct.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs CN approval required for all installations?\u003c\/strong\u003e\u003cbr\u003eOnly for hazardous or regulated industrial environments.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation \u0026amp; Field Engineering Notes\u003c\/h3\u003e\n\u003cp\u003eEnsure probe alignment is verified during installation due to reverse mounting geometry.\u003c\/p\u003e\n\u003cp\u003eMaintain proper gap calibration after installation to ensure linear response accuracy.\u003c\/p\u003e\n\u003cp\u003eAvoid cable tension near connector to prevent long-term mechanical stress.\u003c\/p\u003e\n\u003cp\u003eUse proper grounding and shielding to reduce EMI influence in industrial environments.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Application Guidance\u003c\/h3\u003e\n\u003cp\u003eReverse mount configuration improves installation flexibility in restricted machinery layouts.\u003c\/p\u003e\n\u003cp\u003eNSv design ensures stable vibration measurement in compact rotating equipment.\u003c\/p\u003e\n\u003cp\u003eClickLoc connector improves field reliability under continuous vibration exposure.\u003c\/p\u003e\n\u003cp\u003eSuitable for refinery, power generation, and process industry monitoring systems.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668318810475,"sku":"330906-02-12-10-02-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330906-02-12-10-02-cn-wyzxxlhp0hb_98ae2c0b-5cbd-442a-910d-e7e83476e498.jpg?v=1765521119"},{"product_id":"bently-nevada-330902-00-95-05-02-00-3300-nsv-proximity-probe","title":"Bently Nevada 330902-00-95-05-02-00 3300 NSv Proximity Probe","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 330902-00-95-05-02-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a 3300 NSv proximity probe designed for compact machinery vibration and shaft position measurement. It is typically deployed in small rotating equipment such as auxiliary pumps, compressors, and packaged turbine systems where installation space is restricted but monitoring precision remains critical.\u003c\/p\u003e\n\u003cp\u003eThe NSv architecture focuses on compact geometry and stable signal response under constrained mechanical layouts. The 0.5 meter system length supports short-distance routing, reducing cable exposure in dense machine environments. The ClickLoc connector ensures stable electrical contact under continuous vibration conditions.\u003c\/p\u003e\n\u003cp\u003eThis probe is used in condition monitoring systems where early detection of mechanical instability prevents unplanned downtime.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eConfiguration Breakdown\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eElement\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e330902\u003c\/td\u003e\n\u003ctd\u003e3300 NSv probe series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo unthreaded length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e95\u003c\/td\u003e\n\u003ctd\u003e9.5 in overall case length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003e0.5 m total length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eClickLoc connector, standard cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo agency approval required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThis structure defines probe geometry, installation depth, and system connectivity configuration.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330902-00-95-05-02-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003e3300 NSv proximity probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase Length\u003c\/td\u003e\n\u003ctd\u003e9.5 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Length\u003c\/td\u003e\n\u003ctd\u003e0.5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread Type\u003c\/td\u003e\n\u003ctd\u003e1\/4-28 UNF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eCompact rotating machinery monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs this probe suitable for small machinery installations?\u003c\/strong\u003e\u003cbr\u003eYes. The NSv series is designed for compact equipment with limited mounting space.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it be used with 3300 XL systems?\u003c\/strong\u003e\u003cbr\u003eIt is designed for NSv architecture. Compatibility depends on system configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the advantage of 0.5 m cable length?\u003c\/strong\u003e\u003cbr\u003eIt reduces signal exposure and improves installation cleanliness in tight panels.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes ClickLoc improve reliability?\u003c\/strong\u003e\u003cbr\u003eYes. It reduces connector loosening under vibration conditions.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Installation \u0026amp; Engineering Notes\u003c\/h3\u003e\n\u003cp\u003eEnsure correct probe gap calibration during static alignment to stabilize baseline signal output.\u003c\/p\u003e\n\u003cp\u003eAvoid routing cables near high-current conductors to reduce EMI influence on signal quality.\u003c\/p\u003e\n\u003cp\u003eMaintain proper connector locking to prevent micro-disconnections in vibration-heavy environments.\u003c\/p\u003e\n\u003cp\u003eUse strain relief clamps near entry points to reduce mechanical fatigue.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eIndustrial Application Guidance\u003c\/h3\u003e\n\u003cp\u003eThis probe is optimized for compact rotating assets in industrial monitoring systems.\u003c\/p\u003e\n\u003cp\u003eIt provides stable displacement measurement in environments where traditional probe assemblies are too large.\u003c\/p\u003e\n\u003cp\u003eNSv design reduces installation footprint while maintaining vibration detection accuracy.\u003c\/p\u003e\n\u003cp\u003eProper grounding and shielding practices improve long-term signal stability in industrial environments.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668318843243,"sku":"330902-00-95-05-02-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330902-00-95-05-02-00-zzdrhchkw3n_b284c29a-787b-4c07-ba8e-dbd7a8a6687c.jpg?v=1765521121"},{"product_id":"bently-nevada-330191-00-16-10-cn-3300-xl-8-mm-extended-temperature-range-etr-proximity-probes","title":"Bently Nevada 330191-00-16-10-CN | 3300 XL 8 mm Extended Temperature Range (ETR) Proximity Probes","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 330191-00-16-10-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a 3300 XL 8 mm Extended Temperature Range (ETR) proximity probe designed for vibration and shaft displacement monitoring in high-temperature rotating machinery environments. It is commonly applied in turbines, compressors, and refinery pumps where thermal stability and measurement accuracy directly affect machine protection logic.\u003c\/p\u003e\n\u003cp\u003eThe ETR design extends operating capability beyond standard probe temperature limits, ensuring stable signal behavior in hot housing zones and aggressive industrial conditions. The 1.0 meter system length supports standard installation routing in compact machine assemblies.\u003c\/p\u003e\n\u003cp\u003eCN approval marking supports deployment in regulated hazardous areas with compliance requirements such as ATEX, IECEx, and NEPSI.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eConfiguration Interpretation\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eElement\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e330191\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm ETR probe series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo unthreaded length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003e1.6 in overall case length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e1.0 m total length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCN\u003c\/td\u003e\n\u003ctd\u003eHazardous area approvals (ATEX \/ IECEx \/ NEPSI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThis configuration defines probe geometry, installation depth, and compliance classification for industrial safety environments.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330191-00-16-10-CN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm ETR proximity probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread Type\u003c\/td\u003e\n\u003ctd\u003e3\/8-24 UNF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Length\u003c\/td\u003e\n\u003ctd\u003e1.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase Length\u003c\/td\u003e\n\u003ctd\u003e1.6 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Category\u003c\/td\u003e\n\u003ctd\u003eExtended Temperature Range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApprovals\u003c\/td\u003e\n\u003ctd\u003eATEX, IECEx, NEPSI (CN variant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs this probe suitable for high-temperature turbine environments?\u003c\/strong\u003e\u003cbr\u003eYes. The ETR design supports extended thermal operating conditions in rotating machinery zones.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes CN version change electrical performance?\u003c\/strong\u003e\u003cbr\u003eNo. CN refers to approval and compliance marking only.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it replace standard 3300 XL probes?\u003c\/strong\u003e\u003cbr\u003eYes, if mechanical and electrical specifications match system requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this probe compatible with 3300 XL extension cables?\u003c\/strong\u003e\u003cbr\u003eYes. It integrates with standard 3300 XL system architecture.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation \u0026amp; Field Engineering Notes\u003c\/h3\u003e\n\u003cp\u003eMaintain stable probe gap calibration during cold shutdown conditions for repeatable signal accuracy.\u003c\/p\u003e\n\u003cp\u003eAvoid direct contact between probe cable and hot surfaces to prevent insulation degradation.\u003c\/p\u003e\n\u003cp\u003eUse proper strain relief near connector to reduce vibration-induced mechanical stress.\u003c\/p\u003e\n\u003cp\u003eEnsure proper grounding of cable shield to maintain signal integrity in EMI-heavy environments.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Application Guidance\u003c\/h3\u003e\n\u003cp\u003eThe ETR probe structure is optimized for environments with elevated ambient and housing temperatures.\u003c\/p\u003e\n\u003cp\u003eIt improves signal stability in turbine bearing housings and compressor casings where thermal drift affects standard probes.\u003c\/p\u003e\n\u003cp\u003eMechanical design ensures compatibility with existing 3300 XL installation footprints.\u003c\/p\u003e\n\u003cp\u003eProper installation alignment is critical to avoid phase shift in vibration readings.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668318876011,"sku":"330191-00-16-10-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330191-00-16-10-cn-mgpvarytx5x_848cba76-b85f-4aa7-8dd1-63ab04fbe55f.jpg?v=1765521123"},{"product_id":"bently-nevada-330104-00-04-10-02-cn-3300-xl-8-mm-proximity-probe","title":"Bently Nevada 330104-00-04-10-02-CN 3300 XL 8 mm Proximity Probe","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada \u003cstrong\u003e330104-00-04-10-02-CN\u003c\/strong\u003e is an eddy current proximity transducer probe designed for non-contacting vibration and position measurement applications on fluid-film bearing machinery. It operates by detecting static displacement and dynamic vibration relative to an observed conductive surface, utilizing an eddy current sensing coil encapsulated in a Polyphenylene Sulfide (PPS) tip. Constructed with an AISI 303 or 304 stainless steel case and flexible armor, the \u003cstrong\u003e330104-00-04-10-02-CN\u003c\/strong\u003e transfers signals over a 75 ohm triaxial cable terminated with a gold-plated ClickLoc coaxial connector.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTipLoc Molding:\u003c\/strong\u003e Patented molding process ensures a secure bond between the probe tip and body.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCableLoc Design:\u003c\/strong\u003e Provides 330 N (75 lbf) pull strength at the cable-to-tip connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClickLoc Connector:\u003c\/strong\u003e Gold-plated coaxial connector locks finger-tight to prevent accidental loosening.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegral Armor:\u003c\/strong\u003e Flexible stainless steel armor jacket provides mechanical protection for the probe lead.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure Sealing:\u003c\/strong\u003e Includes an internal Viton O-ring to seal differential pressure between tip and case.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFluid-film bearing machine vibration monitoring\u003c\/li\u003e\n\u003cli\u003eAxial shaft position measurement\u003c\/li\u003e\n\u003cli\u003eKeyphasor timing reference sensing\u003c\/li\u003e\n\u003cli\u003eIndustrial speed and overspeed detection systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOption\u003c\/th\u003e\n\u003cth\u003eOption Description\u003c\/th\u003e\n\u003cth\u003eSelected Code\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnthreaded Length Option\u003c\/td\u003e\n\u003ctd\u003e00 (0 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOverall Case Length Option\u003c\/td\u003e\n\u003ctd\u003e04 (40 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTotal Length Option\u003c\/td\u003e\n\u003ctd\u003e10 (1.0 metre \/ 3.3 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConnector and Cable-Type Option\u003c\/td\u003e\n\u003ctd\u003e02 (Miniature coaxial ClickLoc connector, standard cable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAgency Approval Option\u003c\/td\u003e\n\u003ctd\u003eCN (Approvals country specific)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMade in U.S.A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330104 (M10x1 thread, with armor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Tip Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Case Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAISI 303 or 304 stainless steel (SST)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 ohm triaxial, FEP insulated with SST armor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 mm (80 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecommended Gap Setting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.27 mm (50 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIncremental Scale Factor (ISF)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil) nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Target Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15.2 mm (0.6 in) diameter flat target\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Shaft Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50.8 mm (2 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTensile Strength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330 N (75 lbf) probe case to lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature (Probe\/Lead)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-51 degC to +177 degC (-60 degF to +351 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Bend Radius\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTighten forward-mounted probe case to recommended torque of 11.2 N.m (100 in.lbf); do not exceed 33.9 N.m (300 in.lbf).\u003c\/li\u003e\n\u003cli\u003eEnsure a minimum target diameter of 15.2 mm (0.6 in) directly opposite the probe tip.\u003c\/li\u003e\n\u003cli\u003eMaintain a minimum separation distance between adjacent probe tips of at least 40 mm (1.6 in) for axial position or 38 mm (1.5 in) for radial vibration to minimize cross-talk.\u003c\/li\u003e\n\u003cli\u003eHand-tighten the gold-plated ClickLoc connector until it clicks into place; do not use pliers unless mating with a non-XL stainless steel connector.\u003c\/li\u003e\n\u003cli\u003eObserve the minimum cable bend radius of 25.4 mm (1.0 in) during cable routing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAgency Approval:\u003c\/strong\u003e CN (Approvals country specific)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668318908779,"sku":"330104-00-04-10-02-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330104-00-04-10-02-cn-02wvqkgdr51_32ca5a0a-ba68-4a79-ae16-efacd1bdf16f.jpg?v=1765521124"},{"product_id":"bently-nevada-330910-00-03-10-02-00-3300-nsv-armored-proximity-probe","title":"Bently Nevada 330910-00-03-10-02-00 3300 NSv Armored Proximity Probe","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 330910-00-03-10-02-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a 3300 NSv proximity probe designed for high-precision shaft vibration and position monitoring in compact industrial rotating machinery. It is commonly used in pumps, compressors, small turbines, and auxiliary equipment where installation space is limited but measurement reliability remains critical.\u003c\/p\u003e\n\u003cp\u003eThis probe uses an M10 x 1 threaded mounting interface and armored cable construction to ensure mechanical protection and stable signal transmission in high-vibration environments. It is part of the NSv series, optimized for narrow-space applications while maintaining full compatibility with Bently Nevada monitoring systems.\u003c\/p\u003e\n\u003cp\u003eThe 1.0 meter total length configuration supports flexible routing in confined machinery layouts.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eConfiguration Breakdown\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eElement\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e330910\u003c\/td\u003e\n\u003ctd\u003e3300 NSv probe series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo unthreaded length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e03\u003c\/td\u003e\n\u003ctd\u003e30 mm overall case length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e1.0 m total length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eClickLoc connector with standard cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo agency approval required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThis structure defines probe geometry, installation interface, cable length, and connector configuration.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330910-00-03-10-02-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.014 kg to 0.15 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003e3300 NSv proximity probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread Type\u003c\/td\u003e\n\u003ctd\u003eM10 x 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e1.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArmor\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eVibration and shaft position monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Interpretation Notes\u003c\/h3\u003e\n\u003cp\u003eThe NSv probe series is designed for compact machinery installations where standard probe geometries cannot be applied.\u003c\/p\u003e\n\u003cp\u003eArmored cable construction improves mechanical durability and reduces risk of damage in high-vibration zones.\u003c\/p\u003e\n\u003cp\u003eClickLoc connector design ensures stable electrical connection and reduces loosening under continuous mechanical stress.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Application Notes\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhere is this probe used?\u003c\/strong\u003e\u003cbr\u003eIt is used in small turbines, pumps, compressors, and compact rotating machinery.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy choose NSv probes?\u003c\/strong\u003e\u003cbr\u003eThey are optimized for tight installation spaces with full monitoring capability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes armor improve reliability?\u003c\/strong\u003e\u003cbr\u003eYes. It provides mechanical protection in vibration-intensive environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it compatible with standard Bently Nevada systems?\u003c\/strong\u003e\u003cbr\u003eYes. It integrates with 3300 NSv monitoring architecture.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation \u0026amp; Commissioning Notes\u003c\/h3\u003e\n\u003cp\u003eEnsure correct probe gap setup for accurate linear measurement response.\u003c\/p\u003e\n\u003cp\u003eAvoid sharp bends near connector and armored section to prevent mechanical fatigue.\u003c\/p\u003e\n\u003cp\u003eSecure probe mounting torque according to machine specifications.\u003c\/p\u003e\n\u003cp\u003eMaintain proper grounding of cable shield for signal stability.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Operational Guidance\u003c\/h3\u003e\n\u003cp\u003eUse proper strain relief to prevent connector stress during vibration operation.\u003c\/p\u003e\n\u003cp\u003eInspect armored section periodically for mechanical wear in harsh environments.\u003c\/p\u003e\n\u003cp\u003eMaintain separation from high-power electrical cables to reduce EMI interference.\u003c\/p\u003e\n\u003cp\u003eVerify connector locking during installation to ensure stable signal transmission.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668318974315,"sku":"330910-00-03-10-02-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330910-00-03-10-02-00-p0v5efj5lc2_08a8cbe4-e38d-45c1-b2ca-fd6c2d67b418.jpg?v=1765521125"},{"product_id":"bently-nevada-89477-20-interconnect-cable-20-ft-industrial-signal-link","title":"Bently Nevada 89477-20 Interconnect Cable 20 ft Industrial Signal Link","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 89477-20\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis an interconnect cable designed for vibration monitoring and machinery protection systems where stable signal transmission between field devices and monitoring modules is required. It is commonly used in turbines, compressors, pumps, and industrial rotating equipment across power generation and process industries.\u003c\/p\u003e\n\u003cp\u003eThis cable provides a direct electrical link between system components, ensuring reliable data transfer in environments with vibration, electrical noise, and continuous industrial operation. It supports consistent signal integrity for condition monitoring systems where measurement accuracy directly affects machine protection decisions.\u003c\/p\u003e\n\u003cp\u003eThe 20 ft length configuration supports flexible installation in control cabinets and field-mounted monitoring setups.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eConfiguration Breakdown\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eElement\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e89477\u003c\/td\u003e\n\u003ctd\u003eInterconnect cable series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e20 ft cable length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThis simplified configuration defines cable family type and physical length for system integration.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e89477-20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eInterconnect cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e20 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eSignal transmission for monitoring systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Role\u003c\/td\u003e\n\u003ctd\u003eInterconnect between monitoring and field devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003eIndustrial machinery monitoring systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Interpretation Notes\u003c\/h3\u003e\n\u003cp\u003eThis interconnect cable is designed for stable low-noise signal transmission in industrial environments where electromagnetic interference and mechanical vibration are present.\u003c\/p\u003e\n\u003cp\u003eIt ensures consistent connectivity between monitoring modules and field instrumentation, supporting accurate vibration and condition monitoring data acquisition.\u003c\/p\u003e\n\u003cp\u003eThe cable structure is optimized for durability under continuous industrial operation conditions.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Application Notes\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhere is this cable used?\u003c\/strong\u003e\u003cbr\u003eIt is used in turbine systems, compressors, pumps, and industrial monitoring panels.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is its main function?\u003c\/strong\u003e\u003cbr\u003eIt provides electrical interconnection between monitoring system components.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it suitable for harsh environments?\u003c\/strong\u003e\u003cbr\u003eYes. It is designed for industrial vibration and electrical noise conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes cable length affect performance?\u003c\/strong\u003e\u003cbr\u003eWithin specified design limits, 20 ft supports stable signal transmission.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation \u0026amp; Commissioning Notes\u003c\/h3\u003e\n\u003cp\u003eRoute cable away from high-voltage power lines to minimize electromagnetic interference.\u003c\/p\u003e\n\u003cp\u003eAvoid sharp bends to maintain conductor integrity and signal stability.\u003c\/p\u003e\n\u003cp\u003eEnsure connectors are fully seated to prevent intermittent signal loss.\u003c\/p\u003e\n\u003cp\u003eUse proper cable management to reduce vibration-induced mechanical stress.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Operational Guidance\u003c\/h3\u003e\n\u003cp\u003eMaintain proper grounding practices to ensure signal stability in noisy environments.\u003c\/p\u003e\n\u003cp\u003eInspect connector interfaces during scheduled maintenance cycles.\u003c\/p\u003e\n\u003cp\u003eAvoid mechanical tension on cable ends during installation.\u003c\/p\u003e\n\u003cp\u003eUse standardized routing paths inside control panels to improve reliability.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668319007083,"sku":"89477-20","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/89477-20-3chmqkzrnkk_aeabdb4b-577f-4515-af7c-d9847d23c650.jpg?v=1765521126"},{"product_id":"bently-nevada-21000-00-00-00-039-03-02-proximity-probe-housing-assemblies","title":"Bently Nevada 21000-00-00-00-039-03-02 Proximity Probe Housing Assemblies","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 21000-00-00-00-039-03-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a proximity probe housing assembly designed for industrial vibration monitoring systems where probe protection and mechanical installation flexibility are required. It is widely applied in turbines, compressors, pumps, and rotating machinery used in power plants, refineries, and heavy process industries.\u003c\/p\u003e\n\u003cp\u003eThis configuration supports installations where the probe and cable are not included, allowing system integrators to select external sensing components based on application requirements. It provides a stable mechanical interface for proximity measurement systems while maintaining environmental protection for the sensing point.\u003c\/p\u003e\n\u003cp\u003eThe housing ensures consistent probe positioning and mechanical isolation, improving measurement stability in vibration and shaft displacement monitoring applications.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eMechanical Configuration Breakdown\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eElement\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e21000\u003c\/td\u003e\n\u003ctd\u003eProximity probe housing assembly series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eProbe not required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eProbe cable not required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo standoff adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e039\u003c\/td\u003e\n\u003ctd\u003e3.9 in probe penetration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e03\u003c\/td\u003e\n\u003ctd\u003eNPT fittings with plugs, reducer, and cable sealing grips\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003e3\/4-14 NPT mounting thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThis structure defines a probe-less housing configuration intended for flexible sensor system integration.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e21000-00-00-00-039-03-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eProximity probe housing assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Requirement\u003c\/td\u003e\n\u003ctd\u003eNot included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Requirement\u003c\/td\u003e\n\u003ctd\u003eNot included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Penetration\u003c\/td\u003e\n\u003ctd\u003e3.9 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Thread\u003c\/td\u003e\n\u003ctd\u003e3\/4-14 NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing Material\u003c\/td\u003e\n\u003ctd\u003eAluminum body with 304 stainless steel sleeve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFittings\u003c\/td\u003e\n\u003ctd\u003eNPT plug, reducer, cable seal grip set\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eVibration monitoring system housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Interpretation Notes\u003c\/h3\u003e\n\u003cp\u003eThis housing assembly is designed for system-level flexibility, allowing engineers to integrate preferred probe and cable configurations based on machine monitoring requirements.\u003c\/p\u003e\n\u003cp\u003eThe aluminum body provides lightweight structural support, while the stainless steel sleeve enhances corrosion resistance in industrial environments.\u003c\/p\u003e\n\u003cp\u003eCable sealing grips ensure environmental protection across multiple cable diameter ranges, improving installation adaptability.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Application Notes\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhere is this housing used?\u003c\/strong\u003e\u003cbr\u003eIt is used in turbines, compressors, pumps, and industrial rotating machinery.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is probe not included?\u003c\/strong\u003e\u003cbr\u003eIt allows flexible selection of probe types based on application design.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it be used outdoors?\u003c\/strong\u003e\u003cbr\u003eYes. It is designed for industrial environments with environmental sealing features.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the advantage of modular configuration?\u003c\/strong\u003e\u003cbr\u003eIt supports customized sensor integration for different monitoring architectures.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation \u0026amp; Commissioning Notes\u003c\/h3\u003e\n\u003cp\u003eEnsure correct NPT thread engagement to maintain housing sealing integrity.\u003c\/p\u003e\n\u003cp\u003eSelect appropriate cable seal grip size to match installed cable diameter.\u003c\/p\u003e\n\u003cp\u003eAvoid mechanical stress on housing during probe alignment procedures.\u003c\/p\u003e\n\u003cp\u003eVerify probe penetration alignment before final tightening of assembly.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Operational Guidance\u003c\/h3\u003e\n\u003cp\u003eUse correct sealing components for environmental protection in outdoor installations.\u003c\/p\u003e\n\u003cp\u003eEnsure proper grounding of metallic housing components in electrically noisy environments.\u003c\/p\u003e\n\u003cp\u003eInspect cable seal grips periodically to maintain moisture resistance.\u003c\/p\u003e\n\u003cp\u003eAvoid over-tightening fittings to prevent housing deformation.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668319039851,"sku":"21000-00-00-00-039-03-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/21000-00-00-00-039-03-02-pdou1k3rmdk_83f53142-2932-44a3-bce4-213e9f7d8337.jpg?v=1765521127"},{"product_id":"bently-nevada-32000-16-05-00-080-03-02-32000-metric-proximity-probe-housing","title":"Bently Nevada 32000-16-05-00-080-03-02 | 32000 Metric Proximity Probe Housing","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 32000-16-05-00-080-03-02\u003c\/strong\u003e is a 32000 metric proximity probe housing designed for rugged industrial vibration monitoring applications. It is widely deployed in turbines, compressors, pumps, and heavy rotating machinery where environmental sealing and mechanical protection are required for stable proximity probe operation.\u003c\/p\u003e\n\u003cp\u003eThis housing integrates a 3300 XL 8 mm probe interface and provides sealed mechanical protection for measurement stability in harsh operating environments. It supports reliable shaft vibration and displacement monitoring in power generation, petrochemical, and heavy process industries.\u003c\/p\u003e\n\u003cp\u003eThe reinforced housing structure ensures long-term durability under high vibration, moisture exposure, and industrial contamination conditions.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eMechanical Configuration Breakdown\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eElement\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e32000\u003c\/td\u003e\n\u003ctd\u003eMetric proximity probe housing series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm probe compatibility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003e0.5 m probe cable length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo standoff adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e080\u003c\/td\u003e\n\u003ctd\u003e80 mm probe penetration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e03\u003c\/td\u003e\n\u003ctd\u003eM20 fittings with plugs and armored cable grip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003e3\/4-14 NPT mounting thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eEach parameter defines probe interface geometry, penetration depth, and installation hardware configuration for industrial assembly.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e32000-16-05-00-080-03-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eMetric proximity probe housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Compatibility\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Penetration\u003c\/td\u003e\n\u003ctd\u003e80 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e0.5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Thread\u003c\/td\u003e\n\u003ctd\u003e3\/4-14 NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP66, Type 4X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e-51 to 105 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing Material\u003c\/td\u003e\n\u003ctd\u003eGlass reinforced PPS thermoplastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMetal Components\u003c\/td\u003e\n\u003ctd\u003eAISI 304 and AISI 303 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eO-ring Material\u003c\/td\u003e\n\u003ctd\u003eNeoprene\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eVibration and shaft position monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Interpretation Notes\u003c\/h3\u003e\n\u003cp\u003eThe 32000 housing system is engineered for mechanical isolation and environmental sealing of proximity probes in harsh industrial environments.\u003c\/p\u003e\n\u003cp\u003eGlass reinforced PPS material provides high resistance to chemical exposure and mechanical impact, while maintaining dimensional stability under temperature variation.\u003c\/p\u003e\n\u003cp\u003eStainless steel components ensure corrosion resistance in offshore and chemical processing applications.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Application Notes\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhere is this housing used?\u003c\/strong\u003e\u003cbr\u003eIt is used in turbines, compressors, pumps, and heavy industrial rotating equipment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it suitable for outdoor installation?\u003c\/strong\u003e\u003cbr\u003eYes. IP66 and Type 4X ratings support harsh outdoor environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat makes this housing impact resistant?\u003c\/strong\u003e\u003cbr\u003eCertified structural design allows repeated mechanical impact resistance under extreme temperatures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it be used in hazardous areas?\u003c\/strong\u003e\u003cbr\u003eYes. It meets electrostatic dissipation requirements for hazardous environments.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation \u0026amp; Commissioning Notes\u003c\/h3\u003e\n\u003cp\u003eEnsure correct NPT thread sealing to maintain environmental protection integrity.\u003c\/p\u003e\n\u003cp\u003eVerify probe penetration depth alignment before tightening final assembly.\u003c\/p\u003e\n\u003cp\u003eUse proper torque control during installation to avoid housing stress deformation.\u003c\/p\u003e\n\u003cp\u003eMaintain cable sealing integrity using correct M20 fitting configuration.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Operational Guidance\u003c\/h3\u003e\n\u003cp\u003eAvoid direct mechanical load on housing body during installation.\u003c\/p\u003e\n\u003cp\u003eEnsure grounding continuity for metallic components in hazardous environments.\u003c\/p\u003e\n\u003cp\u003eInspect sealing components periodically in corrosive or offshore environments.\u003c\/p\u003e\n\u003cp\u003eMaintain proper cable strain relief to avoid connector fatigue under vibration.\u003c\/p\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668319072619,"sku":"32000-16-05-00-080-03-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/32000-16-05-00-080-03-02-dswb4ne3znn_5643a083-40e0-4665-9c9a-ec00e19744b4.jpg?v=1765521129"},{"product_id":"bently-nevada-330190-045-00-00-3300-xl-extended-temperature-range-etr-extension-cable","title":"Bently Nevada 330190-045-00-00  | 3300 XL Extended Temperature Range (ETR) Extension Cable","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 330190-045-00-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a 3300 XL Extended Temperature Range (ETR) extension cable designed for vibration monitoring systems operating in thermally demanding industrial environments. It is commonly used in turbines, compressors, and process machinery where stable signal transmission must be maintained under elevated temperature conditions.\u003c\/p\u003e\n\u003cp\u003eThis cable supports reliable data transfer between proximity probes and monitoring modules while minimizing signal drift caused by thermal stress. It is applied in power generation, oil and gas, and heavy industrial systems where temperature stability directly affects machine protection accuracy.\u003c\/p\u003e\n\u003cp\u003eThe 4.5 meter configuration provides flexible routing in compact and mid-range machinery installations.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eConfiguration Breakdown\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eElement\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e330190\u003c\/td\u003e\n\u003ctd\u003e3300 XL ETR extension cable series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e045\u003c\/td\u003e\n\u003ctd\u003e4.5 m cable length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo additional cable option required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo agency approval required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eEach parameter defines cable length and configuration level within the ETR extension cable family.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330190-045-00-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eExtended temperature range extension cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e4.5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Construction\u003c\/td\u003e\n\u003ctd\u003eTriaxial ETR design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eProximity probe signal transmission\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Environment\u003c\/td\u003e\n\u003ctd\u003eHigh temperature industrial systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eBently Nevada 3300 XL series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Interpretation Notes\u003c\/h3\u003e\n\u003cp\u003eThe ETR cable design maintains stable electrical characteristics under elevated temperature conditions where standard extension cables may experience signal drift or insulation degradation.\u003c\/p\u003e\n\u003cp\u003eTriaxial construction ensures low-noise signal transmission and stable impedance performance, which is critical for accurate vibration monitoring in rotating machinery.\u003c\/p\u003e\n\u003cp\u003eThe cable is optimized for integration in high-temperature zones such as turbine casings and compressor housings.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Application Notes\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhere is this cable used?\u003c\/strong\u003e\u003cbr\u003eIt is used in turbines, compressors, and high-temperature industrial machinery.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of ETR design?\u003c\/strong\u003e\u003cbr\u003eIt ensures stable signal performance under elevated thermal conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it compatible with standard 3300 XL systems?\u003c\/strong\u003e\u003cbr\u003eYes. It integrates into the 3300 XL monitoring architecture.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes cable length affect performance?\u003c\/strong\u003e\u003cbr\u003eWithin specification, 4.5 m length maintains stable signal transmission.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation \u0026amp; Commissioning Notes\u003c\/h3\u003e\n\u003cp\u003eAvoid routing near high-temperature steam lines exceeding rated limits.\u003c\/p\u003e\n\u003cp\u003eMaintain proper separation from high-power electrical cables to reduce EMI interference.\u003c\/p\u003e\n\u003cp\u003eEnsure correct connector engagement to maintain signal stability.\u003c\/p\u003e\n\u003cp\u003eUse appropriate cable supports to prevent mechanical stress in high-vibration areas.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Operational Guidance\u003c\/h3\u003e\n\u003cp\u003eMaintain minimum bend radius to protect triaxial shielding integrity.\u003c\/p\u003e\n\u003cp\u003eInspect insulation condition during scheduled maintenance in high-heat environments.\u003c\/p\u003e\n\u003cp\u003eEnsure proper grounding of shielding for optimal noise suppression.\u003c\/p\u003e\n\u003cp\u003eAvoid direct contact with hot surfaces or radiant heat sources.\u003c\/p\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668319105387,"sku":"330190-045-00-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330190-045-00-00-extension-cable-vv44ifx1gve_81f44a4c-8bd7-4af8-8fdb-50fa958ad864.jpg?v=1765440498"},{"product_id":"bently-nevada-330730-080-13-cn-3300-xl-11-mm-extension-cable","title":"Bently Nevada 330730-080-13-CN 3300 XL 11 mm Extension Cable","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 330730-080-13-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a 3300 XL 11 mm extension cable designed for vibration monitoring systems used in heavy industrial rotating machinery. It is widely applied in turbines, compressors, and large motor-driven equipment in power plants, oil refineries, and mining operations.\u003c\/p\u003e\n\u003cp\u003eThis cable ensures stable signal transmission between 11 mm proximity probes and monitoring modules under high vibration and electrically noisy conditions. The armored FluidLoc construction improves mechanical protection and maintains signal integrity in harsh industrial environments.\u003c\/p\u003e\n\u003cp\u003eThe 8.0 meter length supports flexible installation layouts in distributed monitoring architectures while maintaining consistent electrical performance.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eConfiguration Breakdown\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eElement\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e330730\u003c\/td\u003e\n\u003ctd\u003e3300 XL 11 mm extension cable series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e080\u003c\/td\u003e\n\u003ctd\u003e8.0 m cable length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e13\u003c\/td\u003e\n\u003ctd\u003eArmored FluidLoc cable with connector protectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCN\u003c\/td\u003e\n\u003ctd\u003eCountry-specific approvals package\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eEach configuration element defines mechanical protection level, cable length, and compliance classification within the 3300 XL 11 mm system.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330730-080-13-CN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003e11 mm extension cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e8.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Construction\u003c\/td\u003e\n\u003ctd\u003eArmored FluidLoc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eConnector protectors included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eProximity probe signal transmission\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eBently Nevada 3300 XL 11 mm series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Interpretation Notes\u003c\/h3\u003e\n\u003cp\u003eThe 3300 XL 11 mm cable series is engineered for enhanced signal stability in large rotating machinery applications where longer cable runs and higher electromagnetic interference levels are present.\u003c\/p\u003e\n\u003cp\u003eArmored FluidLoc construction provides mechanical durability while maintaining low-noise electrical performance, reducing the risk of signal distortion caused by vibration or cable movement.\u003c\/p\u003e\n\u003cp\u003eConnector protectors improve long-term reliability by preventing contamination and mechanical wear at interface points.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Application Notes\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhere is this cable used?\u003c\/strong\u003e\u003cbr\u003eIt is used in turbines, compressors, and large industrial monitoring systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of armored FluidLoc design?\u003c\/strong\u003e\u003cbr\u003eIt increases mechanical durability and improves signal reliability in harsh environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it compatible with all 11 mm probes?\u003c\/strong\u003e\u003cbr\u003eIt is designed for Bently Nevada 3300 XL 11 mm proximity systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy are connector protectors important?\u003c\/strong\u003e\u003cbr\u003eThey reduce contamination and mechanical damage at connection interfaces.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation \u0026amp; Commissioning Notes\u003c\/h3\u003e\n\u003cp\u003eAvoid tight bending near connector ends to preserve signal stability.\u003c\/p\u003e\n\u003cp\u003eMaintain proper separation from high-voltage cables and VFD systems to reduce interference.\u003c\/p\u003e\n\u003cp\u003eEnsure connector locking is fully engaged during installation.\u003c\/p\u003e\n\u003cp\u003eSecure cable routing to avoid vibration-induced mechanical stress.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Operational Guidance\u003c\/h3\u003e\n\u003cp\u003eUse proper strain relief at both ends to avoid load transfer to connectors.\u003c\/p\u003e\n\u003cp\u003eInspect armor integrity during scheduled maintenance cycles.\u003c\/p\u003e\n\u003cp\u003eMaintain minimum bend radius for armored cable sections.\u003c\/p\u003e\n\u003cp\u003eEnsure grounding continuity for shielding effectiveness in noisy environments.\u003c\/p\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668319138155,"sku":"330730-080-13-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330730-080-13-cn-kzhtnrvtql2_2c22313d-9614-48ef-a61d-d34f6f313b5d.jpg?v=1765521131"},{"product_id":"bently-nevada-330101-00-10-10-02-00-3300-xl-8-mm-proximity-transducer-system","title":"Bently Nevada 330101-00-10-10-02-00 3300 XL 8 mm Proximity Transducer System","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 330101-00-10-10-02-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a 3300 XL 8 mm proximity transducer system designed for precise shaft vibration and position measurement in industrial rotating machinery. It is widely deployed in turbines, compressors, pumps, and generators across power generation, oil and gas, and heavy process industries.\u003c\/p\u003e\n\u003cp\u003eThis system provides stable, high-resolution displacement measurement for machine protection and condition monitoring applications. It supports early detection of mechanical faults such as imbalance, misalignment, and bearing wear, helping reduce unplanned shutdowns and maintenance risk.\u003c\/p\u003e\n\u003cp\u003eThe 1.0 meter system configuration enables compact integration in standard monitoring assemblies while maintaining signal integrity across the full measurement chain.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eConfiguration Breakdown\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eSegment\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e330101\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm probe, 3\/8-24 UNF thread, no armor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo unthreaded length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e1.0 in overall case length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e1.0 m total system length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eClickLoc connector with standard cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo agency approval required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eEach parameter defines probe geometry, mechanical interface, cable length, connector type, and certification scope.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330101-00-10-10-02-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e323 g per meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eProximity transducer system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Size\u003c\/td\u003e\n\u003ctd\u003e8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread Type\u003c\/td\u003e\n\u003ctd\u003e3\/8-24 UNF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e1.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eShaft vibration and position monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Interpretation Notes\u003c\/h3\u003e\n\u003cp\u003eThe 3300 XL transducer system is designed to deliver stable, linear response across industrial vibration ranges. It ensures accurate gap measurement between probe tip and target surface in rotating machinery.\u003c\/p\u003e\n\u003cp\u003eThe ClickLoc connector system improves installation reliability by reducing connector loosening under vibration conditions.\u003c\/p\u003e\n\u003cp\u003eThe system architecture supports consistent calibration behavior across the 3300 XL platform, enabling interchangeability within compatible monitoring systems.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Application Notes\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhere is this system used?\u003c\/strong\u003e\u003cbr\u003eIt is used in turbines, compressors, pumps, and industrial rotating equipment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the main function?\u003c\/strong\u003e\u003cbr\u003eIt measures shaft vibration and radial position.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it compatible with existing 3300 XL systems?\u003c\/strong\u003e\u003cbr\u003eYes. It integrates into standard 3300 XL monitoring architecture.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is system length important?\u003c\/strong\u003e\u003cbr\u003eIt defines installation flexibility and signal routing constraints in machinery layouts.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation \u0026amp; Commissioning Notes\u003c\/h3\u003e\n\u003cp\u003eEnsure correct probe gap setting during installation to maintain linear measurement accuracy.\u003c\/p\u003e\n\u003cp\u003eAvoid excessive bending near the connector to prevent signal degradation under vibration.\u003c\/p\u003e\n\u003cp\u003eVerify mechanical mounting torque to prevent probe displacement during operation.\u003c\/p\u003e\n\u003cp\u003eMaintain separation from high-voltage cables to reduce electromagnetic interference.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Operational Guidance\u003c\/h3\u003e\n\u003cp\u003eUse rigid mounting structures to maintain stable probe-to-target alignment.\u003c\/p\u003e\n\u003cp\u003eInspect connector locking mechanism during scheduled maintenance intervals.\u003c\/p\u003e\n\u003cp\u003eEnsure proper grounding of cable shielding for noise reduction in VFD environments.\u003c\/p\u003e\n\u003cp\u003eAvoid mechanical stress on probe housing during installation and alignment procedures.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668319170923,"sku":"330101-00-10-10-02-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330101-00-10-10-02-00-kzy2kisp4et_3539c89e-d628-4f99-8c51-34fb0fdfc3fa.jpg?v=1765521132"},{"product_id":"bently-nevada-330190-080-00-cn-3300-xl-extended-temperature-range-etr-extension-cable","title":"Bently Nevada 330190-080-00-CN | 3300 XL Extended Temperature Range (ETR) Extension Cable","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 330190-080-00-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a 3300 XL Extended Temperature Range (ETR) extension cable designed for vibration monitoring systems operating in elevated and thermally unstable industrial environments. It is applied in turbines, compressors, petrochemical units, and power generation systems where signal stability must be maintained under continuous thermal stress.\u003c\/p\u003e\n\u003cp\u003eThis cable supports reliable signal transmission between proximity probes and monitoring modules while maintaining electrical integrity across extended temperature conditions. It reduces measurement drift and protects machine protection systems from signal degradation in harsh operating zones.\u003c\/p\u003e\n\u003cp\u003eThe 8.0 meter configuration provides flexible installation for distributed monitoring layouts in large industrial machinery assemblies.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Configuration Breakdown\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eElement\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e330190\u003c\/td\u003e\n\u003ctd\u003e3300 XL extended temperature range cable series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e080\u003c\/td\u003e\n\u003ctd\u003e8.0 m cable length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eStandard cable configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCN\u003c\/td\u003e\n\u003ctd\u003eCountry-specific approvals package\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThis structure defines mechanical configuration, electrical design standard, and compliance classification within the ETR extension cable family.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330190-080-00-CN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eExtended temperature range extension cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e8.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Construction\u003c\/td\u003e\n\u003ctd\u003e75 ohm triaxial, FEP insulated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003e69.9 pF\/m typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Capability\u003c\/td\u003e\n\u003ctd\u003eExtended temperature design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eProximity probe signal transmission\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eBently Nevada 3300 XL systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Interpretation Notes\u003c\/h3\u003e\n\u003cp\u003eThe ETR cable series is designed for environments where standard extension cables cannot maintain stable electrical characteristics under elevated temperatures.\u003c\/p\u003e\n\u003cp\u003eFluoroethylene propylene (FEP) insulation improves thermal resistance and chemical stability, making the cable suitable for oil, gas, and high-temperature industrial environments.\u003c\/p\u003e\n\u003cp\u003eTriaxial construction ensures low-noise signal transmission and stable impedance characteristics across long cable runs.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Application Notes\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhere is this cable used?\u003c\/strong\u003e\u003cbr\u003eIt is used in turbines, compressors, and high-temperature industrial monitoring systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat makes ETR cables different?\u003c\/strong\u003e\u003cbr\u003eThey maintain electrical stability under extended temperature conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it compatible with standard 3300 XL systems?\u003c\/strong\u003e\u003cbr\u003eYes. It is fully compatible with 3300 XL proximity measurement architecture.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is triaxial construction important?\u003c\/strong\u003e\u003cbr\u003eIt reduces noise and improves signal stability in electrically harsh environments.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation \u0026amp; Commissioning Notes\u003c\/h3\u003e\n\u003cp\u003eAvoid routing near high-temperature steam lines or heat sources exceeding rated limits.\u003c\/p\u003e\n\u003cp\u003eEnsure proper grounding of shielding to maintain signal integrity in noisy electrical environments.\u003c\/p\u003e\n\u003cp\u003eMaintain proper bend radius to avoid degradation of triaxial shielding structure.\u003c\/p\u003e\n\u003cp\u003eVerify connector seating before commissioning to ensure stable measurement output.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Operational Guidance\u003c\/h3\u003e\n\u003cp\u003eUse thermal spacing in cable routing to avoid continuous exposure to radiant heat sources.\u003c\/p\u003e\n\u003cp\u003eEnsure proper strain relief at cabinet entry points to prevent mechanical stress transfer.\u003c\/p\u003e\n\u003cp\u003eInspect insulation condition periodically in high-temperature applications.\u003c\/p\u003e\n\u003cp\u003eMaintain separation from high-power electrical cables to minimize EMI interference.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668319203691,"sku":"330190-080-00-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330190-080-00-cn-smlnidfadci_9cfde8bb-9bc1-4ff1-8ff6-c9d3ef82773c.jpg?v=1765521134"},{"product_id":"bently-nevada-330130-040-11-00-3300-xl-extension-cable","title":"Bently Nevada 330130-040-11-00 3300 XL Extension Cable","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 330130-040-11-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a 3300 XL extension cable designed for reliable signal transmission in proximity measurement systems used for vibration and shaft position monitoring. It is commonly deployed in turbines, compressors, generators, and industrial rotating machinery where stable signal integrity directly impacts machine protection performance.\u003c\/p\u003e\n\u003cp\u003eThis cable supports armored FluidLoc construction, which improves resistance to mechanical damage, oil exposure, and harsh industrial handling conditions. It ensures stable electrical continuity between proximity probes and monitoring modules in high-vibration environments.\u003c\/p\u003e\n\u003cp\u003eThe 4.0 meter length configuration provides flexible installation in control cabinets and field-mounted monitoring systems while maintaining signal stability across extended routing paths.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eConstruction \u0026amp; Configuration Breakdown\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eElement\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e330130\u003c\/td\u003e\n\u003ctd\u003e3300 XL extension cable series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e040\u003c\/td\u003e\n\u003ctd\u003e4.0 m cable length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e11\u003c\/td\u003e\n\u003ctd\u003eArmored FluidLoc cable construction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo agency approval required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe configuration defines cable length, mechanical protection level, and compliance scope within the 3300 XL system architecture.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330130-040-11-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eExtension cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e4.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Construction\u003c\/td\u003e\n\u003ctd\u003eArmored FluidLoc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Type\u003c\/td\u003e\n\u003ctd\u003eMechanical abrasion resistant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eProximity probe signal transmission\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eBently Nevada 3300 XL systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Interpretation Notes\u003c\/h3\u003e\n\u003cp\u003eThis extension cable is engineered to maintain low-noise signal transmission between proximity probes and monitoring systems in high-vibration industrial environments.\u003c\/p\u003e\n\u003cp\u003eArmored FluidLoc construction provides enhanced mechanical durability, reducing risk of cable damage during installation and long-term operation in harsh machinery areas.\u003c\/p\u003e\n\u003cp\u003eThe shielding design ensures signal stability in electrically noisy environments such as turbine halls and compressor stations.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Application Notes\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhere is this cable used?\u003c\/strong\u003e\u003cbr\u003eIt is used in vibration monitoring systems for turbines, compressors, and industrial rotating machinery.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of armored FluidLoc design?\u003c\/strong\u003e\u003cbr\u003eIt improves mechanical protection and reduces signal disruption in harsh environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it compatible with all 3300 XL probes?\u003c\/strong\u003e\u003cbr\u003eYes. It is designed for Bently Nevada 3300 XL proximity measurement systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes cable length affect signal quality?\u003c\/strong\u003e\u003cbr\u003eWithin system specifications, 4.0 m length maintains stable signal performance.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation \u0026amp; Commissioning Notes\u003c\/h3\u003e\n\u003cp\u003eAvoid sharp bending during installation to prevent damage to internal conductors and shielding.\u003c\/p\u003e\n\u003cp\u003eMaintain proper separation from high-voltage and VFD cables to reduce electromagnetic interference.\u003c\/p\u003e\n\u003cp\u003eEnsure connectors are fully engaged and locked to prevent intermittent signal loss.\u003c\/p\u003e\n\u003cp\u003eSecure cable routing to avoid mechanical stress from vibration or movement.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Operational Guidance\u003c\/h3\u003e\n\u003cp\u003eMaintain minimum bend radius for armored construction to prevent long-term fatigue.\u003c\/p\u003e\n\u003cp\u003eUse proper strain relief at connection points to protect connector integrity.\u003c\/p\u003e\n\u003cp\u003eInspect cable shielding continuity during commissioning for optimal signal performance.\u003c\/p\u003e\n\u003cp\u003eEnsure proper grounding of system shielding to minimize electrical noise interference.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668319236459,"sku":"330130-040-11-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330130-040-11-00-extension-cable-qn2ay5mvagf_f310ea0b-ffcd-478a-8ed5-6392231e7e8a.jpg?v=1765440915"},{"product_id":"bently-nevada-84661-34-10-meter-velomitor-interconnect-cable","title":"Bently Nevada 84661-34 | 10 meter Velomitor Interconnect Cable","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 84661-34\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a 10 meter Velomitor interconnect cable designed for reliable signal transmission between velocity transducers and vibration monitoring systems. It is used in industrial machinery protection systems across power generation, oil and gas, and process industries where stable vibration signal integrity is critical.\u003c\/p\u003e\n\u003cp\u003eThis cable assembly provides a rugged armored construction to protect signal transmission in high-vibration and harsh environmental conditions. It ensures consistent data transfer from HTVS velocity sensors to monitoring equipment without degradation caused by electrical noise or mechanical stress.\u003c\/p\u003e\n\u003cp\u003eThe stainless steel armor layer enhances mechanical durability, making it suitable for installations exposed to abrasion, moisture, and industrial handling stress.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eConstruction \u0026amp; Design Breakdown\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eElement\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Core\u003c\/td\u003e\n\u003ctd\u003eShielded 22 AWG (0.382 mm2) conductors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArmor\u003c\/td\u003e\n\u003ctd\u003eStainless steel protective layer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor End\u003c\/td\u003e\n\u003ctd\u003eMoisture-resistant female connector (HTVS side)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitor End\u003c\/td\u003e\n\u003ctd\u003eRing lug termination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e10 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe structure is engineered to maintain signal integrity while providing mechanical protection in demanding industrial environments.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e84661-34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eArmored interconnect cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e10 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Size\u003c\/td\u003e\n\u003ctd\u003e22 AWG (0.382 mm2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArmor Material\u003c\/td\u003e\n\u003ctd\u003eStainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-29 to 121 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Connection\u003c\/td\u003e\n\u003ctd\u003eMoisture-resistant female connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitor Connection\u003c\/td\u003e\n\u003ctd\u003eRing lugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eVelocity transducer signal transmission\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Interpretation Notes\u003c\/h3\u003e\n\u003cp\u003eThis interconnect cable is designed to maintain stable low-noise signal transmission between velocity sensors and monitoring systems in electrically and mechanically harsh environments.\u003c\/p\u003e\n\u003cp\u003eStainless steel armor protects the internal conductors from abrasion and mechanical damage during installation and long-term operation.\u003c\/p\u003e\n\u003cp\u003eShielded conductor design reduces electromagnetic interference, ensuring signal accuracy in environments with variable frequency drives and high-power electrical systems.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Application Notes\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhere is this cable used?\u003c\/strong\u003e\u003cbr\u003eIt is used in power plants, refineries, and industrial machinery vibration monitoring systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is armored cable important?\u003c\/strong\u003e\u003cbr\u003eIt protects signal integrity against mechanical damage and harsh industrial handling.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it be used with all Velomitor sensors?\u003c\/strong\u003e\u003cbr\u003eIt is designed for compatible Bently Nevada Velomitor and HTVS systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it reduce electrical noise?\u003c\/strong\u003e\u003cbr\u003eYes. Shielded construction helps minimize EMI interference.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation \u0026amp; Commissioning Notes\u003c\/h3\u003e\n\u003cp\u003eAvoid excessive bending during installation to prevent internal conductor stress.\u003c\/p\u003e\n\u003cp\u003eEnsure proper grounding of shield layer to reduce electromagnetic interference.\u003c\/p\u003e\n\u003cp\u003eRoute cable away from high-voltage and VFD power lines for optimal signal integrity.\u003c\/p\u003e\n\u003cp\u003eSecure stainless steel armor properly at mounting points to prevent vibration-induced fatigue.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Operational Guidance\u003c\/h3\u003e\n\u003cp\u003eMaintain minimum bend radius to avoid long-term mechanical fatigue in armored structure.\u003c\/p\u003e\n\u003cp\u003eInspect connector sealing periodically in moisture-prone environments.\u003c\/p\u003e\n\u003cp\u003eUse proper strain relief at both ends to prevent mechanical load transfer to connectors.\u003c\/p\u003e\n\u003cp\u003eEnsure ring lug termination is firmly secured to monitoring system terminals for stable signal transmission.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668319269227,"sku":"84661-34","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/84661-34-xineykv00ar_bd189d67-6de3-412b-8dbc-91f4c1b8515a.jpg?v=1765521137"},{"product_id":"bently-nevada-1900-65a-00-01-01-cn-01-1900-65a-general-purpose-equipment-monitor","title":"Bently Nevada  1900\/65A-00-01-01-CN-01 | 1900\/65A General Purpose Equipment Monitor","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 1900\/65A-00-01-01-CN-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a general purpose equipment monitor designed for continuous condition monitoring of industrial rotating machinery. It is widely used in power plants, oil and gas facilities, and process industries to supervise vibration, temperature, and auxiliary equipment parameters through a centralized monitoring architecture.\u003c\/p\u003e\n\u003cp\u003eThis monitor supports real-time machine protection logic and integrates with PLC and DCS systems via Modbus communication. It is typically deployed on pumps, compressors, fans, and auxiliary machinery where early fault detection reduces unplanned downtime and protects critical assets.\u003c\/p\u003e\n\u003cp\u003eThe DIN rail mounting design enables compact installation inside control cabinets, supporting high-density industrial automation layouts.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eConfiguration Breakdown\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eSegment\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eMeaning\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1900\/65A\u003c\/td\u003e\n\u003ctd\u003eGeneral purpose equipment monitor series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003e18 to 36 Vdc power supply option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eAttached display module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eDIN rail mounting configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCN\u003c\/td\u003e\n\u003ctd\u003eCountry-specific approval configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eModbus communication interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eEach parameter defines power input range, display configuration, mounting method, certification scope, and communication protocol within the 1900\/65A platform.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1900\/65A-00-01-01-CN-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eGeneral purpose equipment monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e18 to 36 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003eAttached display module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eDIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd\u003eModbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eMachinery condition monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Integration\u003c\/td\u003e\n\u003ctd\u003ePLC, DCS, industrial monitoring systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Interpretation Notes\u003c\/h3\u003e\n\u003cp\u003eThe 1900\/65A platform is designed for centralized monitoring of multiple machine parameters in a single control unit. It reduces system complexity by consolidating data acquisition and alarm logic into a compact DIN rail device.\u003c\/p\u003e\n\u003cp\u003eModbus communication enables straightforward integration into existing industrial automation networks without requiring proprietary interfaces.\u003c\/p\u003e\n\u003cp\u003eThe attached display provides local visualization of machine status, reducing dependency on external HMI systems during commissioning and troubleshooting.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Application Notes\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhere is this monitor used?\u003c\/strong\u003e\u003cbr\u003eIt is used in power plants, refineries, and industrial process facilities.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it integrate with PLC systems?\u003c\/strong\u003e\u003cbr\u003eYes. It supports Modbus communication for PLC and DCS integration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of DIN rail mounting?\u003c\/strong\u003e\u003cbr\u003eIt allows compact and standardized installation inside control cabinets.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it suitable for multi-machine monitoring?\u003c\/strong\u003e\u003cbr\u003eYes. It is designed for general purpose equipment monitoring across multiple assets.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation \u0026amp; Commissioning Notes\u003c\/h3\u003e\n\u003cp\u003eEnsure stable 24 Vdc power supply within specified range to avoid system instability.\u003c\/p\u003e\n\u003cp\u003eInstall on DIN rail with proper mechanical locking to prevent vibration-induced loosening.\u003c\/p\u003e\n\u003cp\u003eRoute communication cables away from high-power circuits to reduce signal interference.\u003c\/p\u003e\n\u003cp\u003eVerify Modbus addressing configuration before system integration to ensure correct data mapping.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Operational Guidance\u003c\/h3\u003e\n\u003cp\u003eMaintain proper cabinet ventilation to avoid thermal accumulation during continuous operation.\u003c\/p\u003e\n\u003cp\u003eUse shielded communication cabling in electrically noisy environments to improve signal integrity.\u003c\/p\u003e\n\u003cp\u003ePerform periodic firmware and configuration checks to maintain monitoring accuracy.\u003c\/p\u003e\n\u003cp\u003eEnsure proper grounding of control cabinet to reduce electromagnetic interference effects.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668319301995,"sku":"1900\/65A-00-01-01-CN-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/190065a-00-01-01-cn-01-nthcmjs01rc_c0105460-47d4-4f07-a321-65c5e2791e08.jpg?v=1765521138"},{"product_id":"bently-nevada-330902-00-15-10-02-cn-3300-nsv-proximity-probe","title":"Bently Nevada 330902-00-15-10-02-CN 3300 NSv Proximity Probe","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 330902-00-15-10-02-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a 3300 NSv armored proximity probe designed for vibration and shaft position measurement in compact rotating machinery. It is typically applied in small turbines, compressors, and pump systems where installation space is limited but measurement stability remains essential for protection systems.\u003c\/p\u003e\n\u003cp\u003eThe NSv architecture focuses on compact geometry and stable signal output under high vibration conditions. The armored cable construction improves mechanical protection in harsh industrial environments where cable abrasion or impact risk exists.\u003c\/p\u003e\n\u003cp\u003eThis model supports 1.0 meter system length and integrates ClickLoc connector technology for stable electrical contact under continuous operation.\u003c\/p\u003e\n\u003cp\u003eThe CN configuration supports ATEX, IECEx, and NEPSI hazardous area compliance requirements.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eConfiguration Breakdown\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eElement\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e330902\u003c\/td\u003e\n\u003ctd\u003e3300 NSv probe series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo unthreaded length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003e1.5 in overall case length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e1.0 m total system length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eClickLoc connector, standard cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCN\u003c\/td\u003e\n\u003ctd\u003eHazardous area approvals (ATEX \/ IECEx \/ NEPSI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThis structure defines probe geometry, installation interface, cable system, and compliance classification.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330902-00-15-10-02-CN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e14 g to 150 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003e3300 NSv armored proximity probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread Type\u003c\/td\u003e\n\u003ctd\u003e1\/4-28 UNF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Length\u003c\/td\u003e\n\u003ctd\u003e1.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase Length\u003c\/td\u003e\n\u003ctd\u003e1.5 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003eArmored\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eCompact rotating machinery monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs this probe suitable for high vibration equipment?\u003c\/strong\u003e\u003cbr\u003eYes. The NSv design and armored cable improve durability in vibration-heavy environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does CN certification include?\u003c\/strong\u003e\u003cbr\u003eIt includes ATEX, IECEx, and NEPSI hazardous area approvals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it be used in standard 3300 XL systems?\u003c\/strong\u003e\u003cbr\u003eNo. It belongs to NSv architecture and requires compatible system configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of armored cable?\u003c\/strong\u003e\u003cbr\u003eIt provides mechanical protection against abrasion and impact damage.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Notes\u003c\/h3\u003e\n\u003cp\u003eEnsure correct probe gap calibration during static installation to maintain measurement accuracy.\u003c\/p\u003e\n\u003cp\u003eAvoid sharp cable bends near connector to prevent armor fatigue and internal conductor stress.\u003c\/p\u003e\n\u003cp\u003eRoute cable away from high-current conductors to reduce EMI influence.\u003c\/p\u003e\n\u003cp\u003eSecure mounting to prevent micro-movement under long-term vibration exposure.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eIndustrial Application Guidance\u003c\/h3\u003e\n\u003cp\u003eNSv armored probes are designed for compact rotating machinery requiring robust mechanical protection.\u003c\/p\u003e\n\u003cp\u003eArmored cable improves reliability in oil mist, dust, and mechanical contact risk environments.\u003c\/p\u003e\n\u003cp\u003eClickLoc connector ensures stable signal transmission under continuous industrial vibration.\u003c\/p\u003e\n\u003cp\u003eSuitable for compressor packages, pumps, and small turbine monitoring systems.\u003c\/p\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668320907627,"sku":"330902-00-15-10-02-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330902-00-15-10-02-cn-qw0htv3mvvg_6b0e0cbe-180f-4a28-bcee-e279b90ad4a0.jpg?v=1765521143"},{"product_id":"bently-nevada-330704-00-05-10-02-cn-3300-xl-11-mm-armored-proximity-probe","title":"Bently Nevada 330704-00-05-10-02-CN 3300 XL 11 mm Armored Proximity Probe","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 330704-00-05-10-02-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a 3300 XL 11 mm armored proximity probe designed for shaft vibration and position monitoring in turbines, compressors, generators, and heavy industrial rotating machinery. It operates within the Bently Nevada 3300 XL eddy-current system and delivers stable displacement signals in harsh mechanical and electrical environments.\u003c\/p\u003e\n\u003cp\u003eThis probe is built for applications requiring enhanced mechanical protection through armored cable construction. It is commonly deployed in refineries, power plants, and offshore installations where vibration, oil exposure, and mechanical abrasion are continuous operating conditions.\u003c\/p\u003e\n\u003cp\u003eThe M14 x 1.5 threaded interface provides secure installation and stable alignment under high vibration loads, ensuring long-term measurement consistency in critical machinery protection systems.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eConfiguration Breakdown\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eSegment\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eMeaning\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e330704\u003c\/td\u003e\n\u003ctd\u003e3300 XL 11 mm armored probe series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003e0 mm unthreaded length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003e5 mm case length option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e1.0 m system cable length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eClickLoc connector with standard cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCN\u003c\/td\u003e\n\u003ctd\u003eCountry-specific approval configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eEach parameter defines probe geometry, cable length, connector type, and regional compliance classification within the 3300 XL probe system.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330704-00-05-10-02-CN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003e11 mm armored proximity probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread Type\u003c\/td\u003e\n\u003ctd\u003eM14 x 1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003eArmored construction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e1.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-51 to 177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Tip Material\u003c\/td\u003e\n\u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Case Material\u003c\/td\u003e\n\u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSealing Material\u003c\/td\u003e\n\u003ctd\u003eViton O-ring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eVibration and shaft position monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Interpretation Notes\u003c\/h3\u003e\n\u003cp\u003eThe armored cable construction provides additional mechanical protection against abrasion, impact, and installation damage in harsh industrial environments. This improves long-term reliability in high-vibration machinery zones.\u003c\/p\u003e\n\u003cp\u003eThe PPS probe tip material ensures stable dielectric performance under elevated temperature conditions, maintaining linear response in eddy-current measurement systems.\u003c\/p\u003e\n\u003cp\u003eThe stainless steel probe body enhances corrosion resistance and mechanical rigidity, supporting long-term deployment in refinery and offshore applications.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Application Notes\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhere is this probe used?\u003c\/strong\u003e\u003cbr\u003eIt is used in turbines, compressors, and heavy rotating machinery in industrial plants.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of armored cable?\u003c\/strong\u003e\u003cbr\u003eIt provides mechanical protection against abrasion and external damage in harsh environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it compatible with standard 3300 XL systems?\u003c\/strong\u003e\u003cbr\u003eYes. It is fully compatible with Bently Nevada 3300 XL monitoring systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it operate in high-temperature zones?\u003c\/strong\u003e\u003cbr\u003eYes. It supports operation up to 177 deg C.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation \u0026amp; Commissioning Notes\u003c\/h3\u003e\n\u003cp\u003eEnsure correct M14 thread torque during installation to prevent misalignment under vibration stress.\u003c\/p\u003e\n\u003cp\u003eAvoid sharp bending of armored cable to maintain internal conductor integrity.\u003c\/p\u003e\n\u003cp\u003eRoute probe cable away from high-voltage and VFD output wiring to reduce EMI influence.\u003c\/p\u003e\n\u003cp\u003eVerify probe gap calibration before system commissioning to ensure correct signal linearity.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Operational Guidance\u003c\/h3\u003e\n\u003cp\u003eMaintain proper cable routing radius to avoid mechanical fatigue in armored sheath over time.\u003c\/p\u003e\n\u003cp\u003eInspect connector locking mechanism during installation to ensure stable electrical contact.\u003c\/p\u003e\n\u003cp\u003eAvoid mechanical shock during installation to protect probe tip alignment accuracy.\u003c\/p\u003e\n\u003cp\u003ePerform periodic inspection in high-vibration environments to ensure long-term stability of mounting and signal output.\u003c\/p\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668321071467,"sku":"330704-00-05-10-02-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330704-00-05-10-02-cn-qj3ibpvxrxi_48670bdc-4c6f-4ee7-b1a5-b70f6137f0ca.jpg?v=1765521144"},{"product_id":"bently-nevada-31000-28-05-15-042-06-02-31000-proximity-probe-housings","title":"Bently Nevada 31000-28-05-15-042-06-02 31000 Proximity Probe Housings","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 31000-28-05-15-042-06-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a 31000 series proximity probe housing assembly designed for 3300 XL 8 mm probe integration in hazardous and heavy-duty industrial environments. It is widely used in turbines, compressors, pumps, and refinery rotating equipment where stable probe positioning and environmental sealing directly impact machine protection reliability.\u003c\/p\u003e\n\u003cp\u003eThis housing supports high-integrity vibration and shaft displacement measurement under extreme mechanical stress, chemical exposure, and wide temperature variations. It is engineered for long-term deployment in critical asset monitoring systems where downtime reduction is a primary operational target.\u003c\/p\u003e\n\u003cp\u003eThe reinforced PPS thermoplastic body with conductive fibers provides electrostatic dissipation, while stainless steel structural elements ensure mechanical stability in high-vibration installations.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eConfiguration Breakdown\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eSegment\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eMeaning\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e31000\u003c\/td\u003e\n\u003ctd\u003e31000 series proximity probe housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e28\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm probe compatibility with approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003e0.5 m probe cable length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003e1.5 in standoff adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e042\u003c\/td\u003e\n\u003ctd\u003e4.2 in probe penetration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e06\u003c\/td\u003e\n\u003ctd\u003eMulti-fitting configuration with reducer and plugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003e3\/4-14 NPT mounting thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eEach segment defines probe compatibility, mechanical depth, mounting geometry, and installation flexibility for hazardous area applications.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e31000-28-05-15-042-06-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eProximity probe housing assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Probe\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e0.5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandoff Adapter\u003c\/td\u003e\n\u003ctd\u003e1.5 in (38 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Penetration\u003c\/td\u003e\n\u003ctd\u003e4.2 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Thread\u003c\/td\u003e\n\u003ctd\u003e3\/4-14 NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing Material\u003c\/td\u003e\n\u003ctd\u003eGlass-reinforced PPS with conductive fibers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMetal Components\u003c\/td\u003e\n\u003ctd\u003eAISI 303 \/ 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeal Material\u003c\/td\u003e\n\u003ctd\u003eNeoprene\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e-51 deg C to 105 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP66, Type 4X certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpact Resistance\u003c\/td\u003e\n\u003ctd\u003eUp to 7 Joule certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eHazardous area machinery monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Interpretation Notes\u003c\/h3\u003e\n\u003cp\u003eThis housing is designed for hazardous industrial zones where electrostatic control and mechanical durability are critical. The conductive PPS material dissipates static charge, reducing ignition risk in explosive atmospheres.\u003c\/p\u003e\n\u003cp\u003eStainless steel reinforcement ensures structural integrity under continuous vibration and thermal cycling conditions common in refinery and offshore installations.\u003c\/p\u003e\n\u003cp\u003eThe impact-tested design ensures survivability in harsh industrial environments where accidental mechanical shocks may occur during maintenance or operation.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Application Notes\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhere is this housing used?\u003c\/strong\u003e\u003cbr\u003eIt is used in refineries, petrochemical plants, offshore platforms, and heavy industrial rotating equipment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is PPS material important?\u003c\/strong\u003e\u003cbr\u003eIt provides electrostatic dissipation and chemical resistance in hazardous environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it suitable for explosion risk areas?\u003c\/strong\u003e\u003cbr\u003eYes. It is certified for hazardous area operation with appropriate protection ratings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of stainless steel structure?\u003c\/strong\u003e\u003cbr\u003eIt improves mechanical strength and corrosion resistance in harsh environments.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation \u0026amp; Commissioning Notes\u003c\/h3\u003e\n\u003cp\u003eEnsure correct NPT torque tightening to maintain sealing integrity in hazardous environments.\u003c\/p\u003e\n\u003cp\u003eVerify proper alignment of probe penetration depth before commissioning to maintain measurement accuracy.\u003c\/p\u003e\n\u003cp\u003eUse approved sealing methods for threaded connections to prevent fluid or gas ingress.\u003c\/p\u003e\n\u003cp\u003eAvoid mechanical stress on housing during installation to preserve internal alignment stability.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Operational Guidance\u003c\/h3\u003e\n\u003cp\u003eMaintain proper grounding strategy to ensure electrostatic discharge performance of conductive housing material.\u003c\/p\u003e\n\u003cp\u003eInspect sealing integrity periodically in corrosive environments such as offshore or chemical plants.\u003c\/p\u003e\n\u003cp\u003eAvoid over-tightening fittings to prevent stress fractures in thermoplastic housing structure.\u003c\/p\u003e\n\u003cp\u003eEnsure cable routing avoids high-voltage conductors to reduce EMI influence on measurement signals.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668321104235,"sku":"31000-28-05-15-042-06-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-31000-28-05-15-042-06-02-proximity-probe-housingassemblies-3zmymb5ddzt_41ebb7ce-f875-430f-9688-e40b999cde6e.jpg?v=1765447145"},{"product_id":"bently-nevada-21000-28-10-0-41-04-02-proximity-probe-housing-assembly","title":"Bently Nevada 21000-28-10-0-41-04-02 Proximity Probe Housing Assembly","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 21000-28-10-0-41-04-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a proximity probe housing assembly designed for secure installation of 3300 XL 8 mm proximity probes in industrial rotating machinery monitoring applications. It is widely applied in turbines, compressors, pumps, and heavy-duty process equipment where stable probe positioning is required for accurate vibration and shaft displacement measurement.\u003c\/p\u003e\n\u003cp\u003eThis housing system provides a rigid mechanical interface between the probe and machine casing, ensuring consistent probe penetration and alignment under continuous vibration and thermal stress. It supports reliable eddy-current signal generation in condition monitoring systems used for asset protection and predictive maintenance.\u003c\/p\u003e\n\u003cp\u003eThe 3\/4-14 NPT mounting interface enables standardized integration into industrial machine housings, supporting both OEM installation and retrofit applications in power generation and process industries.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eConfiguration Breakdown\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eSegment\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eMeaning\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e21000\u003c\/td\u003e\n\u003ctd\u003eProximity probe housing assembly platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e28\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm probe option with approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e1.0 m probe cable length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003ctd\u003eNo standoff adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e41\u003c\/td\u003e\n\u003ctd\u003eProbe penetration configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e04\u003c\/td\u003e\n\u003ctd\u003eOne 3\/4-14 NPT plug included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003e3\/4-14 NPT mounting thread option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eEach parameter defines probe compatibility, installation geometry, penetration depth, and mechanical interface configuration within the housing system architecture.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e21000-28-10-0-41-04-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eProximity probe housing assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Probe\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm proximity probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e1.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Penetration\u003c\/td\u003e\n\u003ctd\u003e41 configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Thread\u003c\/td\u003e\n\u003ctd\u003e3\/4-14 NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandoff Adapter\u003c\/td\u003e\n\u003ctd\u003eNot included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFittings\u003c\/td\u003e\n\u003ctd\u003eOne 3\/4-14 NPT plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eVibration and shaft displacement monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Interpretation Notes\u003c\/h3\u003e\n\u003cp\u003eThis housing assembly ensures fixed mechanical positioning of proximity probes to maintain measurement accuracy in high-vibration industrial environments. It eliminates installation variability caused by mechanical drift, thermal expansion, and housing deformation.\u003c\/p\u003e\n\u003cp\u003eProbe penetration configuration defines the physical depth relationship between probe tip and target surface, which directly affects signal linearity in eddy-current measurement systems.\u003c\/p\u003e\n\u003cp\u003eThe standardized NPT interface simplifies integration into machine housings without requiring custom machining or adapter structures.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Application Notes\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhere is this housing used?\u003c\/strong\u003e\u003cbr\u003eIt is used in turbines, compressors, pumps, and industrial rotating machinery requiring stable probe installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is probe penetration important?\u003c\/strong\u003e\u003cbr\u003eIt ensures correct gap positioning for accurate vibration signal generation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it be used with non-3300 XL probes?\u003c\/strong\u003e\u003cbr\u003eNo. It is designed specifically for Bently Nevada 3300 XL 8 mm probe systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of NPT mounting?\u003c\/strong\u003e\u003cbr\u003eIt allows standardized and reliable mechanical integration into industrial equipment housings.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation \u0026amp; Commissioning Notes\u003c\/h3\u003e\n\u003cp\u003eEnsure correct torque application during NPT thread installation to prevent misalignment or mechanical stress on housing structure.\u003c\/p\u003e\n\u003cp\u003eVerify probe penetration depth before system commissioning to ensure correct calibration of gap voltage output.\u003c\/p\u003e\n\u003cp\u003eMaintain clean mounting surfaces to avoid debris interference affecting probe alignment and measurement stability.\u003c\/p\u003e\n\u003cp\u003eRoute probe cables away from high-voltage conductors and VFD output lines to minimize electromagnetic interference.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Operational Guidance\u003c\/h3\u003e\n\u003cp\u003eAvoid mechanical impact during installation to preserve probe alignment accuracy and housing integrity.\u003c\/p\u003e\n\u003cp\u003eUse appropriate sealing practices on NPT threads to prevent fluid ingress in turbine and compressor environments.\u003c\/p\u003e\n\u003cp\u003eInspect housing periodically in high-vibration machinery to ensure long-term mechanical stability.\u003c\/p\u003e\n\u003cp\u003eEnsure consistent grounding practices to reduce electrical noise in proximity measurement signals.\u003c\/p\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668321137003,"sku":"21000-28-10-0-41-04-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/21000-28-10-0-41-04-02-sx5o0jx4jww_8c8e3708-d83a-4c0f-91b4-f739d7a5557e.jpg?v=1765521146"},{"product_id":"bently-nevada-190501-00-00-00-velomitor-ct-velocity-transducer-1","title":"Bently Nevada 190501-00-00-00 Velomitor CT Velocity Transducer","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 190501-00-00-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a Velomitor CT velocity transducer designed for continuous vibration monitoring of industrial rotating machinery such as pumps, fans, compressors, motors, and auxiliary equipment. It provides direct velocity output for condition monitoring systems used in power generation, oil and gas, and process industries.\u003c\/p\u003e\n\u003cp\u003eThe sensor is engineered for reliable operation in general-purpose machinery protection applications where compact installation and stable long-term vibration measurement are required. It converts mechanical vibration into a proportional velocity signal suitable for PLC, DCS, and dedicated vibration monitoring systems.\u003c\/p\u003e\n\u003cp\u003eThe MIL-C-5015 connection interface ensures robust electrical connectivity in industrial environments with high vibration, thermal cycling, and electrical noise exposure.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eConfiguration Breakdown\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eSegment\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eMeaning\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e190501\u003c\/td\u003e\n\u003ctd\u003eVelomitor CT velocity transducer series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo stud mounting hardware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eMIL-C-5015 electrical connector interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo agency approval requirement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eEach parameter defines mechanical mounting configuration, electrical interface type, and certification scope within the Velomitor CT platform.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e190501-00-00-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.297 kg (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eVelocity transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eMIL-C-5015 interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Hardware\u003c\/td\u003e\n\u003ctd\u003eNo stud\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eVelocity vibration signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eMachinery vibration monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eIndustrial PLC, DCS, and vibration systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Interpretation Notes\u003c\/h3\u003e\n\u003cp\u003eThe Velomitor CT is designed for direct velocity measurement, eliminating the need for external integration or signal conversion in most monitoring systems. This simplifies system architecture in general-purpose machinery protection applications.\u003c\/p\u003e\n\u003cp\u003eThe MIL-C-5015 connector provides rugged electrical connection suitable for industrial environments with continuous vibration and electrical interference.\u003c\/p\u003e\n\u003cp\u003eThe no-stud configuration allows flexible installation using application-specific mounting methods depending on machine housing design.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Application Notes\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhere is this sensor typically used?\u003c\/strong\u003e\u003cbr\u003eIt is used in pumps, fans, compressors, and general industrial rotating machinery.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the advantage of velocity output?\u003c\/strong\u003e\u003cbr\u003eIt provides direct vibration velocity measurement without additional signal conversion.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it replace proximity probes?\u003c\/strong\u003e\u003cbr\u003eNo. It is used for general vibration monitoring, not shaft displacement measurement.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs MIL-C-5015 important?\u003c\/strong\u003e\u003cbr\u003eYes. It ensures secure and reliable electrical connection in harsh industrial environments.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation \u0026amp; Commissioning Notes\u003c\/h3\u003e\n\u003cp\u003eEnsure firm mechanical coupling between sensor and machine surface to achieve accurate vibration transmission.\u003c\/p\u003e\n\u003cp\u003eAvoid loose mounting conditions, as poor coupling directly affects measurement accuracy and signal stability.\u003c\/p\u003e\n\u003cp\u003eRoute signal cables away from high-voltage and VFD output wiring to reduce electromagnetic interference.\u003c\/p\u003e\n\u003cp\u003eVerify connector locking during installation to prevent intermittent signal loss in high-vibration environments.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Operational Guidance\u003c\/h3\u003e\n\u003cp\u003eInstall sensor on rigid machine surfaces to avoid resonance amplification effects in measurement readings.\u003c\/p\u003e\n\u003cp\u003eMaintain proper grounding practices within the monitoring system to reduce electrical noise interference.\u003c\/p\u003e\n\u003cp\u003eAvoid installing in areas with structural flexibility, as this may distort vibration measurement accuracy.\u003c\/p\u003e\n\u003cp\u003ePerform periodic inspection in high-vibration applications to ensure long-term mounting integrity.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668321169771,"sku":"190501-00-00-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-190501-00-00-00-velomitor-ct-velocity-transducer-fgw3fgaxwrd_898b573d-f721-4202-a1ec-90d2c3b0ddd3.jpg?v=1765449534"},{"product_id":"bently-nevada-24701-16-05-00-073-04-02-proximity-probe-housing-assembly","title":"Bently Nevada 24701-16-05-00-073-04-02 Proximity Probe Housing Assembly","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 24701-16-05-00-073-04-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a proximity probe housing assembly designed for secure installation of 3300 XL 8 mm proximity probes in rotating machinery monitoring applications. It is widely applied in turbines, compressors, pumps, and industrial drivetrains where stable probe positioning is required for accurate vibration and shaft displacement measurement.\u003c\/p\u003e\n\u003cp\u003eThis housing assembly provides a mechanically stable interface between the probe and machine casing. It ensures consistent probe penetration depth and alignment, which directly affects signal accuracy in eddy-current measurement systems. The configuration supports harsh industrial environments where vibration, thermal expansion, and mechanical stress are continuous operating conditions.\u003c\/p\u003e\n\u003cp\u003eThe 3\/4-14 NPT mounting interface ensures compatibility with standard industrial threaded ports, making it suitable for both OEM installations and retrofit monitoring upgrades.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eConfiguration Breakdown\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eSegment\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eMeaning\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e24701\u003c\/td\u003e\n\u003ctd\u003eProximity probe housing assembly platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003eCompatible 3300 XL 8 mm probe option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003e0.5 m probe cable length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo standoff adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e073\u003c\/td\u003e\n\u003ctd\u003e7.3 in probe penetration depth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e04\u003c\/td\u003e\n\u003ctd\u003eOne 3\/4-14 NPT plug configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003e3\/4-14 NPT mounting thread option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eEach segment defines probe compatibility, installation geometry, penetration depth, and mechanical interface configuration.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e24701-16-05-00-073-04-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eProximity probe housing assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Probe\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm proximity probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e0.5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Penetration\u003c\/td\u003e\n\u003ctd\u003e7.3 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Thread\u003c\/td\u003e\n\u003ctd\u003e3\/4-14 NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandoff Adapter\u003c\/td\u003e\n\u003ctd\u003eNot included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFittings\u003c\/td\u003e\n\u003ctd\u003eOne 3\/4-14 NPT plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eVibration and shaft displacement monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Interpretation Notes\u003c\/h3\u003e\n\u003cp\u003eThis housing assembly ensures fixed mechanical positioning of proximity probes in applications where probe stability directly affects measurement accuracy. It is designed to eliminate installation drift caused by vibration or thermal expansion in machinery environments.\u003c\/p\u003e\n\u003cp\u003eThe defined penetration depth standardizes probe positioning relative to the target surface, which is critical for maintaining consistent gap voltage in eddy-current measurement systems.\u003c\/p\u003e\n\u003cp\u003eNPT threaded interface allows direct installation into machine housings without custom adapters, simplifying field deployment and maintenance procedures.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Application Notes\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhere is this housing used?\u003c\/strong\u003e\u003cbr\u003eIt is used in turbines, compressors, and industrial rotating equipment requiring stable proximity probe installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is penetration depth important?\u003c\/strong\u003e\u003cbr\u003eIt ensures correct probe-to-target distance for accurate vibration signal generation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it be used with non-3300 XL probes?\u003c\/strong\u003e\u003cbr\u003eNo. It is designed specifically for Bently Nevada 3300 XL 8 mm probes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of NPT mounting?\u003c\/strong\u003e\u003cbr\u003eIt provides standardized mechanical integration into industrial equipment housings.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation \u0026amp; Commissioning Notes\u003c\/h3\u003e\n\u003cp\u003eEnsure correct torque application during NPT thread installation to avoid misalignment or mechanical stress on the housing body.\u003c\/p\u003e\n\u003cp\u003eVerify probe penetration depth before commissioning to maintain correct gap calibration in the measurement system.\u003c\/p\u003e\n\u003cp\u003eMaintain clean internal housing surfaces to avoid debris interference with probe alignment and signal accuracy.\u003c\/p\u003e\n\u003cp\u003eRoute probe cable away from high-voltage and VFD wiring to minimize electromagnetic interference.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Operational Guidance\u003c\/h3\u003e\n\u003cp\u003eAvoid mechanical shock during installation, as it may affect probe alignment and penetration accuracy.\u003c\/p\u003e\n\u003cp\u003eUse proper sealing practices on NPT threads to prevent oil or gas ingress in turbine environments.\u003c\/p\u003e\n\u003cp\u003eInspect housing periodically in high-vibration machinery to ensure mechanical stability over long operating cycles.\u003c\/p\u003e\n\u003cp\u003eEnsure consistent grounding practices to reduce electrical noise in proximity measurement signals.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668321202539,"sku":"24701-16-05-00-073-04-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/24701-16-05-00-073-04-02-peopwauugbn_0a2a054b-bea6-489f-ab4d-dc7701387c7d.jpg?v=1765521149"},{"product_id":"149032-03-bently-nevada-3300-xl-proximitor-sensor-9-0m-system","title":"149032-03 Bently Nevada 3300 XL Proximitor® Sensor (9.0m System)","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e149032-03\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a foundational component of the Bently Nevada\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300 XL Proximity Transducer System\u003c\/strong\u003e. This Proximitor® Sensor acts as the sophisticated signal conditioning brain for eddy current probes. It performs two critical functions: it generates the high-frequency Radio Frequency (RF) signal that excites the probe tip and subsequently converts the returned modulated signal into a usable voltage output.\u003c\/p\u003e\n\u003cp\u003eSpecifically calibrated for a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9.0-meter total system length\u003c\/strong\u003e, the 149032-03 delivers a highly linear 7.87 V\/mm (200 mV\/mil) output proportional to the distance between the probe tip and the observed metal surface. This allows for the non-contact measurement of both static displacement (thrust\/position) and dynamic vibration in high-criticality rotating machinery, including steam turbines, centrifugal compressors, and large-scale industrial motors.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Configuration\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e149032-03\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econfiguration is engineered for seamless integration into 3500 Monitoring Systems or standalone PLC\/DCS architectures.\u003c\/p\u003e\n\u003ch3\u003eSystem Length Calibration (03)\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e-03\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoption indicates a factory calibration for a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9.0-meter (29.5 feet)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003etotal system length. To maintain the specified accuracy and Scale Factor, the combined length of the proximity probe and the extension cable must exactly total 9.0 meters.\u003c\/p\u003e\n\u003ch3\u003eAdvanced Signal Processing\u003c\/h3\u003e\n\u003cp\u003eThe 3300 XL hardware architecture provides superior suppression of \"radio frequency interference\" (RFI). This ensures that the vibration data remains clean even when the sensor is mounted in proximity to high-voltage motor starters or communication equipment.\u003c\/p\u003e\n\u003ch3\u003eRugged Physical Build\u003c\/h3\u003e\n\u003cp\u003eConstructed with a high-grade zinc-plated or aluminum housing, the 149032-03 resists corrosion and provides a robust shielding against electromagnetic noise. The internal electronics are fully encapsulated to prevent failure from moisture or vibration within the local instrument enclosure.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Value\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9.0 Meters (Total Probe + Extension)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Power\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-17.5 VDC to -26 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Sensitivity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.87 V\/mm (200 mV\/mil)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 mm (80 mils)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 Hz (DC) to 10 kHz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51°C to +100°C (-60°F to +212°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDIN Rail or Panel Mount\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e~0.25 Kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300 XL Proximitor® Sensor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoffers significant technical improvements over legacy 3300 and 7200 series models:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eComplete Interchangeability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 149032-03 allows for the replacement of probes or cables without the need for on-site recalibration, provided the total system length remains at 9.0 meters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eImproved Scale Factor Stability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe internal circuitry compensates for temperature variations, ensuring that a vibration reading in the heat of summer is just as accurate as one in the dead of winter.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSelf-Diagnostic Logic:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe sensor maintains a consistent \"Not OK\" status if the probe circuit is broken or shorted, preventing the monitoring system from providing false \"zero-vibration\" data during a sensor failure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eInstallation \u0026amp; Maintenance Guide\u003c\/h2\u003e\n\u003cp\u003eSuccessful deployment depends on correct electrical grounding and physical mounting.\u003c\/p\u003e\n\u003ch3\u003eMounting and Isolation\u003c\/h3\u003e\n\u003cp\u003eMount the Proximitor® on a standard\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e35mm DIN rail\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor directly to a backplate. For optimal performance, ensure the sensor housing is electrically isolated from the machine ground to prevent ground loops. Use the factory-supplied isolation washers if mounting to a metal plate.\u003c\/p\u003e\n\u003ch3\u003ePower and Signal Wiring\u003c\/h3\u003e\n\u003cp\u003eUse high-quality shielded, twisted-pair cable for the connection between the 149032-03 and the monitoring rack. Connect the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e-VT\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Voltage Terminal),\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCOM\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Common), and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eOUT\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Signal) terminals precisely. Ensure the shield is grounded at the monitor end only.\u003c\/p\u003e\n\u003ch3\u003eField Verification\u003c\/h3\u003e\n\u003cp\u003eAfter installation, verify the \"Gap Voltage\" at the PROXIMITOR test points. For a standard 8mm probe, a reading of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e-10.0 VDC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eindicates the probe is positioned at the center of its linear range, providing maximum headroom for both vibration and thrust measurements.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Can I use the 149032-03 with a 5.0-meter cable system?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA1: No. The 149032-03 is specifically calibrated for a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9.0-meter system\u003c\/strong\u003e. Using a 5.0-meter setup will cause a significant Scale Factor error, resulting in vibration readings that are inaccurate by 20% or more. Always match the Proximitor® to your total cable length.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What is the difference between the 149032 series and the older 330180 Proximitors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA2: The 149032 is the updated 3300 XL Proximitor® Sensor. While they share similar footprints, the 149032 offers better RFI immunity and improved thermal stability. It is a direct functional replacement for the older 330180-series modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Does this sensor require a separate power supply?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA3: Yes. It requires a stable\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e-24 VDC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003epower source (standard for Bently Nevada systems). This power is usually provided directly from the 3500\/M or 3701\/M monitoring rack.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: Is the 149032-03 compatible with 11mm or NSv probes?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA4: No. This specific model is designed for use with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300 XL 8mm probes\u003c\/strong\u003e. 11mm and NSv systems require their own dedicated Proximitor® models due to differences in tip diameter and electrical impedance.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668325724523,"sku":"149032-03","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/149032-03-1p4kzakxebm_8577a64c-5a3b-4077-80dd-0ee36d623830.jpg?v=1765521305"}],"url":"https:\/\/www.plcprotech.com\/it\/collections\/new-arrivals.oembed","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}