{"product_id":"abb-acs480-04-03a4-4-lv-ac-general-purpose-drive-module","title":"ABB ACS480-04-03A4-4 LV AC General Purpose Drive Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB ACS480-04-03A4-4\u003c\/strong\u003e is a compact low-voltage AC general purpose drive module engineered for precise motor control in light industrial machinery and variable-torque applications. Operating on a 3-phase supply, this drive delivers reliable performance for standard induction motors in cabinet-mounted installations. It integrates essential features directly into the unit to streamline system integration, reduce engineering time, and optimize energy consumption across continuous and intermittent duty cycles.\u003c\/p\u003e\n\u003cp\u003eDesigned for seamless deployment in automation architectures, the ABB ACS480-04-03A4-4 features intuitive user interfaces, built-in assistants for guided commissioning, and broad fieldbus connectivity. It serves as a dependable control solution for original equipment manufacturers and panel builders seeking high reliability and straightforward configuration in space-constrained electrical enclosures.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCabinet-optimized module design for high-density side-by-side mounting\u003c\/li\u003e\n  \u003cli\u003eBuilt-in assistant control panel with clear graphical display for fast setup\u003c\/li\u003e\n  \u003cli\u003eIntegrated EMC filter and Modbus RTU communication as standard\u003c\/li\u003e\n  \u003cli\u003eSupport for optional plug-in fieldbus adapters for major industrial networks\u003c\/li\u003e\n  \u003cli\u003eEnergy efficiency features including load optimization and low standby losses\u003c\/li\u003e\n  \u003cli\u003eCoated boards for enhanced durability in harsh industrial environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eFans and ventilation systems\u003c\/li\u003e\n  \u003cli\u003eCentrifugal and positive displacement pumps\u003c\/li\u003e\n  \u003cli\u003eIndustrial compressors\u003c\/li\u003e\n  \u003cli\u003eMaterial handling conveyors\u003c\/li\u003e\n  \u003cli\u003eFood and beverage processing machinery\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eABB\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003eLV AC General Purpose Drive Module\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eExact Model\u003c\/td\u003e\n      \u003ctd\u003eACS480-04-03A4-4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRated Output Power (Normal Use)\u003c\/td\u003e\n      \u003ctd\u003e1.1 kW\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRated Output Current (In)\u003c\/td\u003e\n      \u003ctd\u003e3.3 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInput Voltage\u003c\/td\u003e\n      \u003ctd\u003e380 to 480 V (3-phase)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInput Frequency\u003c\/td\u003e\n      \u003ctd\u003e47.5 to 63 Hz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEnclosure Class\u003c\/td\u003e\n      \u003ctd\u003eIP20\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eAnalog Inputs \/ Outputs\u003c\/td\u003e\n      \u003ctd\u003e2 \/ 2\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDigital Inputs \/ Outputs\u003c\/td\u003e\n      \u003ctd\u003e6 DI \/ 3 DO (including relay outputs)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCommunication Interfaces\u003c\/td\u003e\n      \u003ctd\u003eRS-485 (Modbus RTU), USB (for PC tool connection)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n      \u003ctd\u003e223 x 73 x 208 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNet Weight\u003c\/td\u003e\n      \u003ctd\u003e1.7 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCountry of Origin\u003c\/td\u003e\n      \u003ctd\u003eFinland\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eInterface\u003c\/th\u003e\n      \u003cth\u003eFunction\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eL1, L2, L3\u003c\/td\u003e\n      \u003ctd\u003e3-phase line power input terminals\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eU, V, W\u003c\/td\u003e\n      \u003ctd\u003eMotor connection terminals\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDC+, DC- \/ R+\u003c\/td\u003e\n      \u003ctd\u003eDC link and external brake resistor terminals\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eAI1, AI2\u003c\/td\u003e\n      \u003ctd\u003eAnalog voltage\/current inputs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eAO1, AO2\u003c\/td\u003e\n      \u003ctd\u003eAnalog current outputs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDI1 through DI6\u003c\/td\u003e\n      \u003ctd\u003eDigital control inputs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRO1, RO2, RO3\u003c\/td\u003e\n      \u003ctd\u003eRelay output contacts\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePanel Port\u003c\/td\u003e\n      \u003ctd\u003eRJ45 connection for assistant control panel or PC tool\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eVerify that the part number ACS480-04-03A4-4 matches your system requirements and electrical supply ratings.\u003c\/li\u003e\n  \u003cli\u003eEnsure all power sources are completely disconnected and locked out before mechanical or electrical work begins.\u003c\/li\u003e\n  \u003cli\u003eInspect the drive module for any visible shipping damage or condensation before mounting.\u003c\/li\u003e\n  \u003cli\u003eMount the module vertically on a smooth, solid, non-flammable surface inside an appropriate cabinet ensuring required clearance gaps for cooling.\u003c\/li\u003e\n  \u003cli\u003eConnect the incoming 3-phase supply, motor cables, and control wiring in accordance with local electrical codes and the manufacturer terminal designations.\u003c\/li\u003e\n  \u003cli\u003eCheck all wiring connections for security before restoring power and initiating the guided startup assistant.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCE Declaration of Conformity\u003c\/li\u003e\n  \u003cli\u003eUL, cUL approval\u003c\/li\u003e\n  \u003cli\u003eRoHS compliance\u003c\/li\u003e\n  \u003cli\u003eREACH regulation compliance\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52701956145515,"sku":"ACS480-04-03A4-4","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/acs480-04-03a4-4-xb0c0x350pc_182f4fb0-e754-46d3-98e4-49510edeb39a.jpg?v=1766478081","url":"https:\/\/www.plcprotech.com\/it\/products\/abb-acs480-04-03a4-4-lv-ac-general-purpose-drive-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}