{"product_id":"abb-ai910s-3kde175511l9100-s900-i-o-analog-input-module","title":"ABB AI910S 3KDE175511L9100 S900 I\/O Analog Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe ABB AI910S (3KDE175511L9100) is an intrinsically safe analog input module designed for the ABB S900 I\/O remote I\/O family. This 4-channel module (AI4-Ex) is engineered to interface field signals from hazardous areas directly into distributed control systems (DCS). It provides galvanic isolation between field inputs, system power, and internal bus communication, ensuring reliable and safe signal conditioning in explosive industrial atmospheres.\u003c\/p\u003e\n\u003cp\u003eAs part of the modular S900 I\/O system, the AI910S mounts onto standard termination units and supports zone 1 and zone 2 hazardous location installations. It processes standard industrial analog signals such as current and voltage inputs from transmitters, thermocouples, or resistance temperature detectors. The module includes comprehensive diagnostic capabilities to monitor for wire breaks, short circuits, and out-of-range conditions, communicating status flags back to the host control system.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eFour intrinsically safe analog input channels (AI4-Ex) for hazardous area signal acquisition\u003c\/li\u003e\n  \u003cli\u003eDesigned for integration within the ABB S900 remote I\/O product family\u003c\/li\u003e\n  \u003cli\u003eSupports connection of standard industrial transmitters and sensors\u003c\/li\u003e\n  \u003cli\u003eGalvanic isolation between channels, power supply, and system bus\u003c\/li\u003e\n  \u003cli\u003eBuilt-in channel diagnostics for wire break, short circuit, and overrange\/underrange detection\u003c\/li\u003e\n  \u003cli\u003eHot-swappable design allows module replacement without powering down the entire station\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eChemical and petrochemical processing plants\u003c\/li\u003e\n  \u003cli\u003eOil and gas upstream and downstream installations\u003c\/li\u003e\n  \u003cli\u003ePharmaceutical manufacturing facilities\u003c\/li\u003e\n  \u003cli\u003eHazardous environments requiring intrinsically safe I\/O interfaces\u003c\/li\u003e\n  \u003cli\u003eDistributed control system (DCS) remote data acquisition\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eABB\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Series\u003c\/td\u003e\n      \u003ctd\u003eS900 I\/O\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModel \/ Ordering Number\u003c\/td\u003e\n      \u003ctd\u003eAI910S \/ 3KDE175511L9100\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModule Type\u003c\/td\u003e\n      \u003ctd\u003eAnalog Input Module (AI4-Ex)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNumber of Channels\u003c\/td\u003e\n      \u003ctd\u003e4 channels\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEx-Rating\u003c\/td\u003e\n      \u003ctd\u003eIntrinsically safe [Ex ia] IIC \/ [Ex ia] IIB\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCommunication\u003c\/td\u003e\n      \u003ctd\u003eS900 I\/O backplane bus\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMounting\u003c\/td\u003e\n      \u003ctd\u003eS900 Series termination unit (DIN rail)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCountry of Origin\u003c\/td\u003e\n      \u003ctd\u003eGermany\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNet Weight\u003c\/td\u003e\n      \u003ctd\u003e0.25 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eVerify that the part number on the module matches your system engineering documentation.\u003c\/li\u003e\n  \u003cli\u003eEnsure all power supplies and field circuits are de-energized before handling hardware.\u003c\/li\u003e\n  \u003cli\u003eInspect the S900 termination unit for physical damage or debris in the connector pins.\u003c\/li\u003e\n  \u003cli\u003eMount the AI910S module securely onto the designated termination unit slot following proper mechanical alignment.\u003c\/li\u003e\n  \u003cli\u003eConnect field wiring to the designated intrinsically safe terminals, maintaining proper separation from non-Ex wiring.\u003c\/li\u003e\n  \u003cli\u003eApply power to the station and verify module status via system diagnostic LEDs and the host DCS configuration software.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668621422955,"sku":"ABB AI910S 3KDE175511L9100","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-ai910s-3kde175511l9100-analog-input-ai4-ex-fpdzk0yxv5h_8731e694-cb8c-43ac-b74d-a7fb00e2da9f.jpg?v=1765535814","url":"https:\/\/www.plcprotech.com\/it\/products\/abb-ai910s-3kde175511l9100-s900-i-o-analog-input-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}