{"product_id":"abb-ci920s-3bds014111-communication-interface-cipb-ex","title":"ABB CI920S 3BDS014111 Communication Interface CIPB-Ex","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe ABB CI920S 3BDS014111 (3BDS014111-50) is a specialized communication interface module designed for hazardous area applications within the ABB AC500 PLC and control system ecosystem. Operating as a CIPB-Ex interface, this module facilitates secure, explosion-protected data exchange and networking capabilities for distributed control and automation architectures. It provides reliable connectivity between standard control environments and field devices installed in potentially explosive atmospheres.\u003c\/p\u003e\n\u003cp\u003eEngineered for demanding industrial installations, the CI920S module supports robust communication protocols to ensure deterministic data transfer and high network availability. Its design integrates diagnostic features that simplify system monitoring, error detection, and maintenance workflows, contributing to maximized uptime in continuous process industries.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDesigned for ABB AC500 control system architectures and related automation platforms\u003c\/li\u003e\n  \u003cli\u003eExplosion-protected CIPB-Ex specification for hazardous industrial locations\u003c\/li\u003e\n  \u003cli\u003eHigh-integrity communication interface supporting reliable field device networking\u003c\/li\u003e\n  \u003cli\u003eIntegrated diagnostic indicators for rapid status monitoring and troubleshooting\u003c\/li\u003e\n  \u003cli\u003eRobust industrial construction built to withstand harsh environmental conditions\u003c\/li\u003e\n  \u003cli\u003eDIN-rail mountable for efficient panel integration and space-saving installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eProcess automation and control in oil, gas, and petrochemical facilities\u003c\/li\u003e\n  \u003cli\u003eChemical and pharmaceutical manufacturing plants with hazardous classification areas\u003c\/li\u003e\n  \u003cli\u003eWater and wastewater treatment infrastructure requiring remote telemetry\u003c\/li\u003e\n  \u003cli\u003ePower generation and distribution control systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eABB\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eExact Model\u003c\/td\u003e\n      \u003ctd\u003eCI920S \/ 3BDS014111\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003eCommunication Interface CIPB-Ex\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Range\u003c\/td\u003e\n      \u003ctd\u003eABB AC500\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMounting Type\u003c\/td\u003e\n      \u003ctd\u003eDIN Rail\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCountry of Origin\u003c\/td\u003e\n      \u003ctd\u003eSweden\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNet Weight\u003c\/td\u003e\n      \u003ctd\u003e0.12 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDimensions\u003c\/td\u003e\n      \u003ctd\u003e2.0 x 10.5 x 11.0 cm\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eVerify the part number and inspect the CI920S module for any transit damage prior to installation.\u003c\/li\u003e\n  \u003cli\u003eEnsure all power to the control panel and associated backplanes is de-energized and locked out.\u003c\/li\u003e\n  \u003cli\u003eMount the communication interface securely onto the designated DIN rail within the cabinet.\u003c\/li\u003e\n  \u003cli\u003eConnect ground and shielding provisions according to hazardous area wiring standards.\u003c\/li\u003e\n  \u003cli\u003eAttach communication cables and apply power to initiate configuration and network handshaking.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668615098731,"sku":"CI920S 3BDS014111","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-ci920s-3bds014111-communication-interface-cipb-ex-rzp1p0jof4j_aae146b1-0581-447d-843a-25d5239298e1.jpg?v=1765535635","url":"https:\/\/www.plcprotech.com\/it\/products\/abb-ci920s-3bds014111-communication-interface-cipb-ex","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}