{"product_id":"allen-bradley-1756-hsc-b-controllogix-high-speed-counter-module","title":"Allen-Bradley 1756-HSC\/B ControlLogix Modulo contatore ad alta velocità","description":"\u003ch3\u003ePanoramica del prodotto\u003c\/h3\u003e\n\u003cp\u003eIl\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1756-HSC\/B\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eè un modulo contatore ad alta velocità (HSC) ad alte prestazioni, progettato per la piattaforma Allen-Bradley ControlLogix. Questo modulo è concepito per applicazioni di conteggio e controllo del movimento di precisione che superano le capacità di scansione dei moduli di ingresso digitali standard. È in grado di elaborare con estrema accuratezza flussi di impulsi rapidi provenienti da encoder, misuratori di portata e sensori di prossimità.\u003c\/p\u003e\n\u003cp\u003eLa versione\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eserie B\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edi questo modulo offre una stabilità migliorata ed è un componente essenziale per le applicazioni che richiedono il rilevamento di eventi ad alta velocità, come le linee di imbottigliamento, la movimentazione dei materiali e il monitoraggio della velocità delle turbine. Spostando la logica di conteggio dalla CPU all'hardware del modulo, il\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1756-HSC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003egarantisce che gli impulsi non vengano mai \"persi\" a causa delle variazioni del tempo di scansione del PLC.\u003c\/p\u003e\n\u003ch3\u003eConfigurazione tecnica\u003c\/h3\u003e\n\u003cp\u003eIl 1756-HSC offre solide funzionalità di I\/O pensate per il conteggio industriale:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eArchitettura a doppio contatore:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edispone di due contatori indipendenti, consentendo il monitoraggio simultaneo di due diversi processi ad alta velocità.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTre ingressi per contatore:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eogni contatore accetta tre ingressi (in genere segnali A, B e Z\/indice), supportando gli encoder in quadratura completi per il rilevamento della direzione e della posizione.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSegnali di uscita quadrupli:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003einclude quattro uscite fisiche configurabili per l'attivazione in base a specifici valori di conteggio (valore preimpostato\/valore corrente), consentendo risposte hardware in tempo reale.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRisposta ad alta velocità:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprogettato per gestire frequenze fino a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1 MHz\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(in determinate configurazioni), offrendo la risoluzione necessaria per la produzione ad alta velocità.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEfficienza energetica:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eassorbe solo 300 mA dal backplane a 5,1 V e appena 3 mA dalla sorgente a 24 V, con un consumo totale ridotto sul backplane di 1,6 watt.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifiche tecniche\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCaratteristica\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDettagli delle specifiche\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModello\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1756-HSC (serie B)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMarchio\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley (Rockwell Automation)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLinea di prodotti\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eControlLogix\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCanali del contatore\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIngressi per contatore\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3 (A, B e Z)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eUscite\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCorrente del backplane\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e300 mA a 5,1 V CC \/ 3 mA a 24 V CC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDissipazione massima di potenza\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5,6 watt a 60 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDissipazione termica\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e19,1 BTU\/ora\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTemperatura di esercizio\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDa 0 a 60 °C (da 32 a 140 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLarghezza dello slot\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 slot\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePeso\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0,23 kg (0,50 lb)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eFAQ tecniche\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQual è la differenza tra la Serie A e la Serie B?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSebbene entrambe le serie condividano le stesse specifiche funzionali di base, la Serie B include generalmente revisioni hardware che migliorano la durata dei componenti e la resistenza alle interferenze elettromagnetiche (EMI). Per la maggior parte delle applicazioni, la Serie B è preferibile grazie alla compatibilità aggiornata del firmware e alla maggiore protezione dei circuiti.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuesto modulo supporta un encoder incrementale standard?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSì. La configurazione a tre ingressi per contatore è progettata specificamente per gli encoder incrementali. Supporta la decodifica in quadratura X1, X2 e X4, nonché il conteggio Su\/Giù e le modalità Impulso\/Direzione.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIl modulo richiede un'alimentazione esterna per gli ingressi?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSì. Gli ingressi e le uscite del 1756-HSC richiedono un'alimentazione esterna per il campo (in genere 12\/24 V CC). La corrente del backplane indicata è esclusivamente destinata alla logica interna del modulo e alla comunicazione con la CPU ControlLogix.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eGuida alla progettazione e all'installazione\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCablaggio e integrità del segnale\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIl conteggio ad alta velocità è estremamente sensibile al rumore elettrico. Per evitare \"conteggi fantasma\":\u003c\/p\u003e\n\u003col class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSchermatura:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUtilizzare cavi schermati a doppino intrecciato di alta qualità per tutti i collegamenti dell'encoder. Collegare la schermatura a un unico punto di messa a terra sul telaio.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInstradamento dei cavi:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNon instradare mai i cavi dell'encoder nella stessa canalina o nello stesso portacavi dei cavi dei motori CA ad alta tensione o dei cavi di uscita dei VFD.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMorsettiera:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAssicurarsi che la morsettiera rimovibile 1756-TBCH o 1756-TBSH (a 36 pin) sia inserita correttamente.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eConfigurazione del modulo in Studio 5000\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eQuando si aggiunge il\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1756-HSC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eall'albero I\/O:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSelezione del filtro:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConfigurare i filtri degli ingressi in base alla frequenza degli impulsi prevista. Impostare un filtro troppo basso può \"smussare\" impulsi ad alta velocità legittimi, mentre un'impostazione troppo alta può consentire il conteggio del rumore.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModalità contatore:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSelezionare \"Contatore\" (per il totalizzatore) oppure \"Encoder\" (per il posizionamento).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMemorizzazione:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUtilizzare la funzione \"Memorizzazione\" per acquisire il valore di conteggio corrente durante una transizione specifica dell'ingresso 'Z', per sequenze di homing precise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eGestione termica\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIl modulo 1756-HSC dissipa fino a 5,6 Watt. Assicurarsi che il telaio ControlLogix sia montato in un armadio ben ventilato. Se la temperatura interna dell'armadio si avvicina a 60 °C, valutare l'utilizzo di un raffreddamento ad aria forzata per evitare la riduzione delle prestazioni termiche della precisione di conteggio.\u003c\/p\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695190569323,"sku":"1756-HSC\/B","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-1756-hsc-b-hsc-module-ra4uewbbisd_8c782b85-0ecf-4a79-8a3b-67662f5047df.jpg?v=1766114611","url":"https:\/\/www.plcprotech.com\/it\/products\/allen-bradley-1756-hsc-b-controllogix-high-speed-counter-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}