{"product_id":"allen-bradley-1756-l83e-controllogix-5580-controller","title":"Allen-Bradley 1756-L83E ControlLogix 5580 Controller","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 1756-L83E\u003c\/strong\u003e is a high-performance \u003cstrong\u003eControlLogix 5580 controller\u003c\/strong\u003e designed for demanding industrial automation, high-speed motion, and complex process control applications within the Integrated Architecture framework. Featuring \u003cstrong\u003e10 MB of user memory\u003c\/strong\u003e, this \u003cstrong\u003eprogrammable automation controller\u003c\/strong\u003e integrates an \u003cstrong\u003eembedded Gigabit Ethernet port\u003c\/strong\u003e to enable direct connection, high-speed communication, and seamless data exchange across industrial EtherNet\/IP networks without requiring a dedicated communication card.\u003c\/p\u003e\n\u003cp\u003eOperating within standard \u003cstrong\u003e1756 ControlLogix chassis\u003c\/strong\u003e, the \u003cstrong\u003e1756-L83E\u003c\/strong\u003e supports up to \u003cstrong\u003e128,000 digital I\/O points\u003c\/strong\u003e and \u003cstrong\u003e4,000 analog I\/O points\u003c\/strong\u003e, delivering exceptionally high message processing rates and real-time execution. The module incorporates \u003cstrong\u003eCIP Security\u003c\/strong\u003e capabilities, an \u003cstrong\u003eembedded non-removable energy storage module\u003c\/strong\u003e to protect volatile data upon power loss, and a pre-installed \u003cstrong\u003e4 GB microSD card\u003c\/strong\u003e for nonvolatile memory storage. It supports full controller redundancy, multi-discipline control across relay ladder logic, structured text, function block diagrams, and sequential function charts.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBuilt-in 10\/100\/1000 Mbps embedded Ethernet port for direct network communication and CIP Security support\u003c\/li\u003e\n\u003cli\u003eSupports up to 250 EtherNet\/IP nodes and 20,000 OPC UA nodes for extensive device integration\u003c\/li\u003e\n\u003cli\u003eIntegrated Motion control over EtherNet\/IP network and SERCOS interface support\u003c\/li\u003e\n\u003cli\u003eHigh-speed execution with capacity for 32 controller tasks (combination of continuous, periodic, and event tasks)\u003c\/li\u003e\n\u003cli\u003eMulti-language programming support including Relay Ladder Logic, Structured Text, Function Block Diagram, and Sequential Function Chart\u003c\/li\u003e\n\u003cli\u003eEmbedded non-removable energy storage module eliminating the requirement for external batteries\u003c\/li\u003e\n\u003cli\u003ePre-installed 4 GB nonvolatile microSD storage card (1784-SD4) for program and data backup\u003c\/li\u003e\n\u003cli\u003eFull support for controller redundancy systems to maximize operational availability\u003c\/li\u003e\n\u003cli\u003eFront USB 2.0 port for local programming, firmware updates, and system configuration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFactory automation and high-speed discrete manufacturing systems\u003c\/li\u003e\n\u003cli\u003eIntegrated Motion control for multi-axis machinery and packaging equipment\u003c\/li\u003e\n\u003cli\u003ePlant-wide process automation and batch control architectures\u003c\/li\u003e\n\u003cli\u003eHigh-availability redundant control architectures for critical infrastructure\u003c\/li\u003e\n\u003cli\u003eEnergy, power generation, and utility automation systems\u003c\/li\u003e\n\u003cli\u003eOil \u0026amp; gas pipeline monitoring and distributed process control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eConformal Coated\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1756-L83E\u003c\/td\u003e\n\u003ctd\u003eControlLogix 5580 Standard Controller, 10 MB Memory\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1756-L83EK\u003c\/td\u003e\n\u003ctd\u003eControlLogix 5580 Conformal Coated Controller, 10 MB Memory\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1756-L83EXT\u003c\/td\u003e\n\u003ctd\u003eControlLogix-XT 5580 Extended Temperature Controller, 10 MB Memory\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1756-L83E-NSE\u003c\/td\u003e\n\u003ctd\u003eControlLogix 5580 No Stored Energy Controller, 10 MB Memory\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1756-L83EP\u003c\/td\u003e\n\u003ctd\u003eControlLogix 5580 Process Controller, 10 MB Memory\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eRockwell Automation \/ Allen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1756-L83E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003eControlLogix 5580\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard User Memory\u003c\/td\u003e\n\u003ctd\u003e10 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital I\/O Capacity\u003c\/td\u003e\n\u003ctd\u003e128,000 max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog I\/O Capacity\u003c\/td\u003e\n\u003ctd\u003e4,000 max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal I\/O Capacity\u003c\/td\u003e\n\u003ctd\u003e128,000 max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmbedded Ethernet Port\u003c\/td\u003e\n\u003ctd\u003e1x RJ45 Port (10\/100\/1000 Mbps)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB Port\u003c\/td\u003e\n\u003ctd\u003e1x USB 2.0 Type-B Port (Full speed 12 Mbps)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEtherNet\/IP Nodes Supported\u003c\/td\u003e\n\u003ctd\u003eUp to 250 nodes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOPC UA Nodes Supported\u003c\/td\u003e\n\u003ctd\u003eUp to 20,000 nodes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNonvolatile Memory Storage\u003c\/td\u003e\n\u003ctd\u003e4 GB SD Card (1784-SD4 pre-installed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Storage Module\u003c\/td\u003e\n\u003ctd\u003eEmbedded, non-removable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Draw @ 1.2V DC\u003c\/td\u003e\n\u003ctd\u003e5.0 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Draw @ 5.1V DC\u003c\/td\u003e\n\u003ctd\u003e1.20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003e6.2 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal Dissipation\u003c\/td\u003e\n\u003ctd\u003e21.2 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Power Cycles\u003c\/td\u003e\n\u003ctd\u003e80,000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e50V (continuous), Basic Insulation type, USB-to-backplane, Ethernet-to-backplane, USB-to-Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Slot Width\u003c\/td\u003e\n\u003ctd\u003e1 slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocation\u003c\/td\u003e\n\u003ctd\u003eChassis-based, any slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Chassis\u003c\/td\u003e\n\u003ctd\u003e1756-A4, 1756-A4K, 1756-A7, 1756-A7K, 1756-A10, 1756-A10K, 1756-A13, 1756-A13K, 1756-A17, 1756-A17K (Series B \u0026amp; C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Standard Power Supplies\u003c\/td\u003e\n\u003ctd\u003e1756-PA50, 1756-PA50K, 1756-PA72, 1756-PA72K, 1756-PA75, 1756-PA75K, 1756-PB50, 1756-PB50K, 1756-PB72, 1756-PB72K, 1756-PB75, 1756-PB75K, 1756-PC75, 1756-PH75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Redundant Power Supplies\u003c\/td\u003e\n\u003ctd\u003e1756-PA75R, 1756-PA75RK, 1756-PB75R, 1756-PB75RK, 1756-PSCA2, 1756-PSCA2K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Code\u003c\/td\u003e\n\u003ctd\u003eT4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 degC to +60 degC (+32 degF to +140 degF) for Series C chassis; 0 degC to +50 degC (+32 degF to +122 degF) for Series B chassis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNonoperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC (-40 degF to +185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% noncondensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Type Rating\u003c\/td\u003e\n\u003ctd\u003eNone (open-style)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.394 kg (0.868 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eInterface \/ Port\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmbedded Ethernet Port (RJ45)\u003c\/td\u003e\n\u003ctd\u003e10\/100\/1000 Mbps industrial EtherNet\/IP communication port for I\/O, HMI, messaging, and CIP Security\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB Port (USB 2.0)\u003c\/td\u003e\n\u003ctd\u003eTemporary local programming, configuration, firmware updates, and online editing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Connector\u003c\/td\u003e\n\u003ctd\u003eHigh-speed multi-gigabit ControlLogix backplane interface for local chassis I\/O and communication modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSD Card Slot\u003c\/td\u003e\n\u003ctd\u003eSecure Digital slot housing pre-installed nonvolatile 4 GB microSD card (1784-SD4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Mounting:\u003c\/strong\u003e Ensure the ControlLogix chassis is powered off before inserting or removing the controller module into any available chassis slot.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Verify proper chassis grounding in accordance with Industrial Automation Wiring and Grounding Guidelines (publication 1770-4.1).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Routing:\u003c\/strong\u003e Use industrial-grade Category 5e or Category 6 Ethernet cabling rated for industrial environments following IEC 61918 and IEC 61784-5-2 guidelines.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUSB Usage:\u003c\/strong\u003e The front USB port is intended only for temporary local programming and diagnostic purposes; do not use USB connection in hazardous location environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVentilation:\u003c\/strong\u003e Maintain adequate space around the chassis enclosure to ensure proper thermal dissipation and prevent ambient temperatures from exceeding 60 degC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOpen-Style Enclosure:\u003c\/strong\u003e Install the module inside an appropriate NEMA or IP-rated industrial protective enclosure to safeguard against airborne contaminants.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ec-UL-us:\u003c\/strong\u003e UL Listed Industrial Control Equipment (UL File E65584); UL Listed for Class I, Division 2 Group A, B, C, D Hazardous Locations (UL File E194810)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFM:\u003c\/strong\u003e FM Approved Equipment for use in Class I, Division 2 Group A, B, C, D Hazardous Locations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e European Union 2014\/30\/EU EMC Directive compliant (EN 61326-1, EN 61000-6-2, EN 61000-6-4, EN 61131-2)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX:\u003c\/strong\u003e European Union 2014\/34\/EU ATEX Directive compliant (EN IEC 60079-0, EN IEC 60079-7, II 3 G Ex ec IIC T4 Gc, Certificate UL 22 ATEX 2817X)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIECEx:\u003c\/strong\u003e IECEx System compliant (IEC 60079-0, IEC 60079-7, II 3 G Ex ec IIC T4 Gc, Certificate IECEx UL 22.0062X)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKEX \/ UKCA:\u003c\/strong\u003e Compliant with UK Electromagnetic Compatibility and Explosive Atmospheres Regulations 2016\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRCM:\u003c\/strong\u003e Australian Radiocommunications Act compliant with EN 61000-6-4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKC:\u003c\/strong\u003e Korean Registration of Broadcasting and Communications Equipment compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification (2020122309111998)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEtherNet\/IP \u0026amp; CIP Security:\u003c\/strong\u003e ODVA conformance tested to EtherNet\/IP and CIP Security specifications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTUV Certified for Security:\u003c\/strong\u003e IEC 62443-4-2 SL1 security certified\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695179002219,"sku":"1756-L83E","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-1756-l83e-controllogix-controllers-iyu41xv3a1i_ff77b1b3-6430-40f8-8300-676879aef41c.jpg?v=1766114230","url":"https:\/\/www.plcprotech.com\/it\/products\/allen-bradley-1756-l83e-controllogix-5580-controller","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}