{"product_id":"allen-bradley-1756-l85e-controllogix-5580-programmable-automation-controller","title":"Allen-Bradley 1756-L85E ControlLogix 5580 Programmable Automation Controller","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 1756-L85E\u003c\/strong\u003e is a ControlLogix 5580 Programmable Automation Controller engineered to deliver high-capacity processing, real-time control, and integrated communication within the Allen-Bradley ControlLogix system architecture. Operating as a high-performance CPU module inside a standard or extreme-environment 1756 chassis, the \u003cstrong\u003e1756-L85E\u003c\/strong\u003e coordinates complex discrete, motion, and process control tasks across demanding industrial environments.\u003c\/p\u003e\n\u003cp\u003eFeaturing high-density program storage and multi-tasking execution, the \u003cstrong\u003e1756-L85E\u003c\/strong\u003e controller supports up to \u003cstrong\u003e32 distinct tasks\u003c\/strong\u003e with up to \u003cstrong\u003e1000 programs per task\u003c\/strong\u003e. The unit features an embedded \u003cstrong\u003e1 Gb Ethernet port\u003c\/strong\u003e (supporting 10\/100\/1000 Mbps operation) for network integration, motion control, and distributed I\/O communication, alongside an onboard \u003cstrong\u003eUSB port\u003c\/strong\u003e for local engineering maintenance and programming.\u003c\/p\u003e\n\u003cp\u003eDesigned for flexible deployment in industrial backplanes, the module operates without local I\/O event trigger limitations and includes a front-panel 4-character diagnostic display for real-time status monitoring. An included \u003cstrong\u003e2 GB Secure Digital (SD) card (1784-SD2)\u003c\/strong\u003e provides optional nonvolatile memory to store program code, tag metadata, and backup configurations.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Capacity Task Execution\u003c\/strong\u003e: Supports up to 32 independent tasks and up to 1000 programs per task to handle large-scale automation routines.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGigabit Ethernet Connectivity\u003c\/strong\u003e: Features an onboard RJ45 Ethernet port supporting 10, 100, and 1000 Mbps speeds for deterministic system-wide networking.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Motion Capabilities\u003c\/strong\u003e: Enables Motion over EtherNet\/IP for up to 256 axes via the embedded high-performance Ethernet port.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocal Maintenance Interface\u003c\/strong\u003e: Equipped with a USB port offering up to 12 Mbps transfer rates for temporary programming and diagnostic access.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNonvolatile Data Backup\u003c\/strong\u003e: Ships with a preinstalled 1784-SD2 2 GB SD card for secure user program and tag data storage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReal-Time System Diagnostics\u003c\/strong\u003e: Front-panel 4-character LED display and status indicators enable instant operational verification and fault isolation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnrestricted Local Event Triggers\u003c\/strong\u003e: Operates without limit on local I\/O event triggers to maximize real-time processing responsiveness.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Speed Discrete Manufacturing\u003c\/strong\u003e: Fast execution of complex logic and motion routines in automated assembly, packaging, and material handling systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDistributed Motion Control\u003c\/strong\u003e: Coordination of multi-axis drives over EtherNet\/IP networks without dedicated motion interface modules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcess Automation \u0026amp; DCS Integration\u003c\/strong\u003e: Centralized logic processing and continuous control within plant-wide ControlLogix platform architectures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Density I\/O Networks\u003c\/strong\u003e: Large-scale data acquisition and control across distributed Ethernet, ControlNet, and DeviceNet remote I\/O nodes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley \/ Rockwell Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003eControlLogix 5580\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1756-L85E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eProgrammable Automation Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Type Rating\u003c\/td\u003e\n\u003ctd\u003eOpen-style\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Weight\u003c\/td\u003e\n\u003ctd\u003eApprox. 394 g (0.868 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eSystem Performance \u0026amp; Memory\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Number of Tasks\u003c\/td\u003e\n\u003ctd\u003e32 Tasks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Programs per Task\u003c\/td\u003e\n\u003ctd\u003e1000 Programs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotion Axis Capacity\u003c\/td\u003e\n\u003ctd\u003eIntegrated Motion over EtherNet\/IP up to 256 axes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvent Triggers Option\u003c\/td\u003e\n\u003ctd\u003eNo limit for local I\/O triggers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNonvolatile Memory\u003c\/td\u003e\n\u003ctd\u003e2 GB Secure Digital Card (1784-SD2 preinstalled)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eElectrical \u0026amp; Power Ratings\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current (5.1V DC)\u003c\/td\u003e\n\u003ctd\u003e1200 mA @ 5.1V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current (1.2V DC)\u003c\/td\u003e\n\u003ctd\u003e5.0 mA @ 1.2V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e50V (continuous), Basic Insulation type, USB-to-Backplane, Ethernet-to-Backplane, and USB-to-Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Test Voltage\u003c\/td\u003e\n\u003ctd\u003eType tested at 1000V AC for 60 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eCommunication Interfaces\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmbedded Ethernet Port\u003c\/td\u003e\n\u003ctd\u003e1 Port (RJ45), 10\/100\/1000 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB Interface Port\u003c\/td\u003e\n\u003ctd\u003e1 Port (USB 2.0 full-speed up to 12 Mbps)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Communications\u003c\/td\u003e\n\u003ctd\u003eEthernet, DeviceNet, ControlNet, Remote I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eEnvironmental Ratings\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature (Chassis Series C)\u003c\/td\u003e\n\u003ctd\u003e0 degC to +60 degC (+32 degF to +140 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature (Chassis Series B)\u003c\/td\u003e\n\u003ctd\u003e0 degC to +50 degC (+32 degF to +122 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Surrounding Air Temperature\u003c\/td\u003e\n\u003ctd\u003e60 degC (140 degF) in Series C chassis \/ 50 degC (122 degF) in Series B chassis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConformal Coated\u003c\/td\u003e\n\u003ctd\u003eNo (Standard Version)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Code\u003c\/td\u003e\n\u003ctd\u003eT4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEthernet Port (RJ45)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePrimary network connection for EtherNet\/IP communication, motion control, and distributed I\/O messaging.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUSB Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLocal maintenance interface for temporary programming and firmware loading via Studio 5000.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSD Card Slot\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHolds the removable 1784-SD2 Secure Digital card for program data storage behind the protective door.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMode Switch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThree-position key switch to select RUN, PROG (Program), or REM (Remote) operating mode.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e4-Character Display\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVisual readout for controller status, diagnostic codes, and initialization messages.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrostatic Discharge (ESD) Protection\u003c\/strong\u003e: Always wear an approved grounding wrist strap and handle the controller circuit board only by its housing to prevent static damage to internal components.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Compatibility Check\u003c\/strong\u003e: Ensure the host 1756 ControlLogix chassis and power supply are installed and powered down before insertion. Note that operation up to 60 degC requires a Series C chassis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhysical Mounting\u003c\/strong\u003e: Align the top and bottom circuit board guides with the chosen slot in the 1756 backplane and slide the module firmly until it latches flush with adjacent units.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMemory \u0026amp; Key Initialization\u003c\/strong\u003e: Confirm the 1784-SD2 card is properly seated in its slot behind the front door and insert the 1756-KY1 mode switch key.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Cabling\u003c\/strong\u003e: Connect standard Category 5e\/6 shielded Ethernet cabling to the onboard RJ45 port following IEC 61918 industrial wiring practices.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eConfiguration Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eFirmware Matching\u003c\/strong\u003e: Verify and match controller firmware revisions using Rockwell Automation Product Compatibility and Download Center (PCDC) prior to commissioning.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP Address Assignment\u003c\/strong\u003e: Set the Ethernet port IP configuration using RSLinx Classic or Studio 5000 Logix Designer software.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUSB Usage Limits\u003c\/strong\u003e: Restrict USB port connections to temporary local maintenance using un-hubbed cables shorter than 3.0 meters (9.84 ft).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProgram Backup\u003c\/strong\u003e: Write final application logic and tag databases to the nonvolatile 2 GB SD card to ensure rapid restore capability after power cycles.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":53723859222891,"sku":"1756-L85E","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/1756-L85E_001_1200x1200_c456b216-22ef-4ec6-988b-38e228fba65e.jpg?v=1786709754","url":"https:\/\/www.plcprotech.com\/it\/products\/allen-bradley-1756-l85e-controllogix-5580-programmable-automation-controller","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}