{"product_id":"allen-bradley-5069-l330erms2-compact-guardlogix-5380-sil2-safety-controller","title":"Allen-Bradley 5069-L330ERMS2 Compact GuardLogix 5380 SIL2 Safety Controller","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 5069-L330ERMS2\u003c\/strong\u003e is a Compact GuardLogix 5380 safety controller designed for high-performance machine control, integrated motion, and functional safety applications. Functioning as a dual-core processing unit within the CompactLogix platform, it supports standard control tasks while executing dedicated safety routines up to Safety Integrity Level 2 (SIL 2) and Performance Level d (PLd). The controller features 3.0 MB of standard user memory and 1.5 MB of safety user memory, providing a robust execution environment for complex ladder logic, structured text, function blocks, and motion commands.\u003c\/p\u003e\n\u003cp\u003eBuilt with dual embedded Ethernet ports, the \u003cstrong\u003e5069-L330ERMS2\u003c\/strong\u003e supports high-speed network topologies including Device Level Ring (DLR), Linear, and Star configurations. It provides native CIP Safety over EtherNet\/IP, enabling secure communication with distributed safety I\/O modules, drives, and field devices. Equipped with integrated motion capability, the unit can control up to 16 motion axes over an EtherNet\/IP network. The controller directly interfaces with up to 31 local Compact 5000 I\/O modules and manages up to 60 network nodes, serving as a scalable control hub for automated production lines and safety-critical machinery.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual-Memory Architecture:\u003c\/strong\u003e Equips 3.0 MB of standard memory and 1.5 MB of dedicated safety memory for high-integrity program execution.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunctional Safety Compliance:\u003c\/strong\u003e Achieves SIL 2 (IEC 61508) and PLd (ISO 13849-1) functional safety performance via dedicated safety tasks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Motion Control:\u003c\/strong\u003e Supports up to 16 axes of CIP Motion over EtherNet\/IP for synchronized servo and drive control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Network Topologies:\u003c\/strong\u003e Embedded dual Ethernet ports support Gigabit communication rates in DLR, Linear, and Star configurations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual-IP \u0026amp; Network Isolation:\u003c\/strong\u003e Supports Dual-IP mode to separate enterprise-level traffic from local machine-level device networks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocal Expansion Capability:\u003c\/strong\u003e Interfaces directly with up to 31 local Compact 5000 standard and safety I\/O modules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScalable Node Limit:\u003c\/strong\u003e Manages up to 60 EtherNet\/IP network nodes for remote I\/O, drives, and human-machine interfaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemovable Storage:\u003c\/strong\u003e Includes a 1784-SD2 Secure Digital card slot for non-volatile project backup, restore, and diagnostic logging.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety-Critical Machine Control:\u003c\/strong\u003e Safeguarding robotic cells, automated assembly lines, packaging machinery, and material handling systems requiring SIL 2 \/ PLd functional safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSynchronized Motion Systems:\u003c\/strong\u003e Controlling multi-axis servo drives, gantry systems, and indexing tables utilizing CIP Motion over EtherNet\/IP.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDistributed Industrial Networks:\u003c\/strong\u003e Interfacing central control systems with remote Compact 5000 I\/O, Guard I\/O, and POINT Guard I\/O across DLR networks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley \/ Rockwell Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eCompact GuardLogix 5380\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExact Model\u003c\/td\u003e\n\u003ctd\u003e5069-L330ERMS2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eCompact GuardLogix SIL2 Safety Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Memory\u003c\/td\u003e\n\u003ctd\u003e3.0 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Memory\u003c\/td\u003e\n\u003ctd\u003e1.5 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEtherNet\/IP Network Nodes\u003c\/td\u003e\n\u003ctd\u003e60 max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal I\/O Expansion\u003c\/td\u003e\n\u003ctd\u003e31 Compact 5000 I\/O modules max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated Motion Axes\u003c\/td\u003e\n\u003ctd\u003e16 axes max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eController Tasks\u003c\/td\u003e\n\u003ctd\u003e32 total tasks (31 standard tasks + 1 safety task)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrograms per Task\u003c\/td\u003e\n\u003ctd\u003e1000 max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-volatile Memory\u003c\/td\u003e\n\u003ctd\u003e1784-SD2 (1 GB) shipped with controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eElectrical \u0026amp; Power\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMOD Power Source Requirement\u003c\/td\u003e\n\u003ctd\u003e18...32V DC (SELV\/PELV rated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMOD Power Bus Current Limit\u003c\/td\u003e\n\u003ctd\u003e5 A max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSA Power Source Requirement\u003c\/td\u003e\n\u003ctd\u003e18...32V DC (SELV\/PELV rated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSA Power Bus Current Limit\u003c\/td\u003e\n\u003ctd\u003e10 A max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation at Full Load\u003c\/td\u003e\n\u003ctd\u003e9 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e4-character status display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eCommunication\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmbedded Communication Ports\u003c\/td\u003e\n\u003ctd\u003e2 x Ethernet (10\/100\/1000 Mbps RJ45), 1 x USB 2.0 Type B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Topologies\u003c\/td\u003e\n\u003ctd\u003eDevice Level Ring (DLR), Linear, Star\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEtherNet\/IP Modes\u003c\/td\u003e\n\u003ctd\u003eDual-IP mode, Linear\/DLR mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Protocols\u003c\/td\u003e\n\u003ctd\u003eEtherNet\/IP, CIP Safety, CIP Sync, Socket Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Port A1\u003c\/td\u003e\n\u003ctd\u003ePrimary network interface for DLR, Linear, or Device-level EtherNet\/IP connections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Port A2\u003c\/td\u003e\n\u003ctd\u003eSecondary network interface for Enterprise-level or dual-IP network separation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB Port\u003c\/td\u003e\n\u003ctd\u003eType B 2.0 full-speed port for local programming, firmware update, and diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMOD Power RTB\u003c\/td\u003e\n\u003ctd\u003eRemovable terminal block connection for 24V DC SELV\/PELV module power bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSA Power RTB\u003c\/td\u003e\n\u003ctd\u003eRemovable terminal block connection for 24V DC SELV\/PELV sensor\/actuator power bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSD Card Slot\u003c\/td\u003e\n\u003ctd\u003eHouses the 1784-SD2 card for firmware, project backup, and system diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Requirements:\u003c\/strong\u003e Install the controller in an IP54-rated (or equivalent) protective industrial enclosure accessible only with a tool.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Mounting:\u003c\/strong\u003e Secure the controller onto a standard EN 50022 35 x 7.5 mm or 35 x 15 mm DIN rail prior to wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Isolation:\u003c\/strong\u003e Ensure separate SELV\/PELV-listed 24V DC external power sources are provided for the MOD power and SA power terminal blocks to prevent system noise propagation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Verification:\u003c\/strong\u003e Verify correct polarity and wire gauge for MOD power (max 5 A bus limit) and SA power (max 10 A bus limit) connectors before applying power.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBus Termination:\u003c\/strong\u003e Always install the 5069-ECR end cap on the final Compact 5000 module or controller right side to protect internal power and communication buses from short circuits or ESD damage.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eConfiguration and Commissioning\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSoftware Environment:\u003c\/strong\u003e Configure the safety controller using Studio 5000 Logix Designer version 31.00.00 or later.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP Address Assignment:\u003c\/strong\u003e Assign network communication parameters using the BOOTP\/DHCP utility, RSLinx Classic, or Studio 5000 over USB or Ethernet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Network Number (SNN):\u003c\/strong\u003e Generate and assign a unique Safety Network Number to the controller and associated CIP Safety devices in the project tree to validate safety cross-checking.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Locking:\u003c\/strong\u003e Once safety routines and program logic are verified, generate the Safety Signature and apply safety-lock protection via Studio 5000 to prevent unauthorized logic modifications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-Volatile Backup:\u003c\/strong\u003e Transfer the fully validated project logic and network configuration onto the installed 1784-SD2 card for automatic restore on power cycles.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":53724037579115,"sku":"5069-L330ERMS2","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/5069-L330ERMS2_001_1200x1200_1244bb18-88b4-4ae4-8592-9825842ed3e0.jpg?v=1786712010","url":"https:\/\/www.plcprotech.com\/it\/products\/allen-bradley-5069-l330erms2-compact-guardlogix-5380-sil2-safety-controller","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}