{"product_id":"allen-bradley-5069-l330erms3-compact-guardlogix-5380-sil3-safety-controller","title":"Allen-Bradley 5069-L330ERMS3 Compact GuardLogix 5380 SIL3 Safety Controller","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 5069-L330ERMS3\u003c\/strong\u003e is a Compact GuardLogix 5380 safety controller designed to deliver high-performance standard and safety control for demanding industrial applications. Engineered on a quad-core processor architecture, this safety controller integrates dedicated system and safety memory to execute complex logic, integrated motion over EtherNet\/IP, and safety functions within a single unified platform. It provides functional safety capability up to SIL 3 (IEC 62061) and Performance Level e (PL e, ISO 13849-1), making it ideal for machinery and process applications requiring stringent safety standards.\u003c\/p\u003e\n\u003cp\u003eThe controller is equipped with 3.0 MB of standard user memory and 1.5 MB of dedicated safety memory. It supports system expansion with up to 31 local Compact 5000 I\/O modules, up to 60 EtherNet\/IP nodes, and up to 16 motion axes. Built-in dual gigabit EtherNet\/IP ports offer versatile networking configurations, supporting Dual-IP mode for separate network segmentation or Linear\/DLR (Device Level Ring) topologies for fault-tolerant network resiliency. System configuration and safety programming are performed seamlessly using the Studio 5000 Logix Designer application (version 32 or later).\u003c\/p\u003e\n\u003cp\u003ePower distribution across the \u003cstrong\u003e5069-L330ERMS3\u003c\/strong\u003e system relies on two distinct external connections: Module Power (MOD), which drives the controller processor and local I\/O module electronics, and Sensor\/Actuator Power (SA), which delivers power to field-side devices. For functional safety compliance, both MOD and SA power circuits require SELV\/PELV certified power supplies. Physical installation is simplified via DIN-rail mounting, featuring integrated chassis grounding directly through a zinc-plated chromate DIN rail.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Integrity Functional Safety\u003c\/strong\u003e: Certified for SIL 3 \/ SILCL 3 (EN 62061 \/ IEC 61508) and Cat. 4 \/ PL e (EN ISO 13849-1) safety execution.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Performance Memory Architecture\u003c\/strong\u003e: Features 3.0 MB standard memory and 1.5 MB dedicated safety memory driven by a quad-core processor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Motion Capability\u003c\/strong\u003e: Supports up to 16 axes of motion control over EtherNet\/IP alongside standard and safety logic execution.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Dual Gigabit Ethernet\u003c\/strong\u003e: Dual 1 Gb EtherNet\/IP ports support Dual-IP addressing for separate network segments or Linear\/DLR topologies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocal I\/O Capacity\u003c\/strong\u003e: Direct local expansion supporting up to 31 Compact 5000 I\/O modules on the right side of the controller.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Isolated Power Structure\u003c\/strong\u003e: Separate MOD (system-side) and SA (field-side) power connections isolate control electronics from field device transients.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOnboard Diagnostic Display\u003c\/strong\u003e: Features a 4-character visual status display and multiple LED indicators for immediate system, power, and network status diagnostics.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard USB Maintenance Port\u003c\/strong\u003e: Includes an front-panel USB port for local temporary programming, firmware flashing, and initial IP address configuration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomotive Assembly \u0026amp; Robotic Cells\u003c\/strong\u003e: Executing SIL 3 functional safety, interlocking, emergency stop monitoring, and multi-axis synchronized drive control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial Handling \u0026amp; High-Speed Packaging\u003c\/strong\u003e: Managing complex sorting, conveyancing, integrated motion, and safety light curtains over EtherNet\/IP networks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcess Machinery Safety Systems\u003c\/strong\u003e: Coordinating safe torque off (STO), safety zone control, and standard process logic in automated production lines.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiscrete Manufacturing Equipment\u003c\/strong\u003e: Providing dual-network segmentation and integrated motion control for standalone or networked OEM machine tools.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eRockwell Automation \/ Allen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand \/ Platform\u003c\/td\u003e\n\u003ctd\u003eCompact GuardLogix 5380\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e5069-L330ERMS3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Identifier\u003c\/td\u003e\n\u003ctd\u003e889508554129\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eSingapore\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor\u003c\/td\u003e\n\u003ctd\u003eQuad Core\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Memory\u003c\/td\u003e\n\u003ctd\u003e3.0 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Memory\u003c\/td\u003e\n\u003ctd\u003e1.5 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Local I\/O Expansion\u003c\/td\u003e\n\u003ctd\u003e31 Compact 5000 I\/O modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax EtherNet\/IP Nodes\u003c\/td\u003e\n\u003ctd\u003e60 nodes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotion Axis Support\u003c\/td\u003e\n\u003ctd\u003e16 axes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e4-character status display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eElectrical \u0026amp; Power Distribution\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMOD Power Voltage Range\u003c\/td\u003e\n\u003ctd\u003e18…32V DC SELV\/PELV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMOD Power Bus Max Current\u003c\/td\u003e\n\u003ctd\u003e5 A max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMOD Power Inrush Current\u003c\/td\u003e\n\u003ctd\u003e2.375 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSA Power Voltage Range\u003c\/td\u003e\n\u003ctd\u003e0…32V DC SELV\/PELV (for safety applications)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSA Power Bus Max Current\u003c\/td\u003e\n\u003ctd\u003e10 A max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation at Full Load\u003c\/td\u003e\n\u003ctd\u003e18 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Power Consumption\u003c\/td\u003e\n\u003ctd\u003eConsumes power from MOD power bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eCommunication \u0026amp; Connectivity\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Ports\u003c\/td\u003e\n\u003ctd\u003e2 x 1 Gb EtherNet ports (RJ45)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Network Topologies\u003c\/td\u003e\n\u003ctd\u003eDual-IP, Linear, Device Level Ring (DLR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB Port\u003c\/td\u003e\n\u003ctd\u003e1 x USB port (temporary programming only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB Cable Length\u003c\/td\u003e\n\u003ctd\u003e3.0 m max (no hubs allowed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eMechanical \u0026amp; Environmental\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eEN50022 - 35 x 7.5 mm zinc-plated chromate steel DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 degC (32 to 140 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Type\u003c\/td\u003e\n\u003ctd\u003eOpen-type rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrounding Connection\u003c\/td\u003e\n\u003ctd\u003eDirect chassis grounding via DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e123.0 mm x 136.81 mm x 132.43 mm (4.84 in. x 5.39 in. x 5.21 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eIsolation\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSA and MOD to Module Bus\u003c\/td\u003e\n\u003ctd\u003e300V (continuous), basic insulation type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet to Module Bus\u003c\/td\u003e\n\u003ctd\u003e300V (continuous), basic insulation type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet to MOD Power\u003c\/td\u003e\n\u003ctd\u003e300V (continuous), double insulation type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet to SA Power\u003c\/td\u003e\n\u003ctd\u003e300V (continuous), double insulation type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB to Module Bus\u003c\/td\u003e\n\u003ctd\u003e300V (continuous), basic insulation type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB to MOD \/ SA Power\u003c\/td\u003e\n\u003ctd\u003e300V (continuous), double insulation type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Type Test\u003c\/td\u003e\n\u003ctd\u003e1500V AC for 60 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnection Point\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription \/ Function\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMOD Power Terminal Block\u003c\/td\u003e\n\u003ctd\u003eRemovable Terminal Block (5069-RTB4) for connecting +24V DC system power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSA Power Terminal Block\u003c\/td\u003e\n\u003ctd\u003eRemovable Terminal Block (5069-RTB6) for connecting +24V DC field sensor\/actuator power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDual RJ45 Ports\u003c\/td\u003e\n\u003ctd\u003eLocated on the bottom of the controller for 10\/100\/1000 Mbps EtherNet\/IP network connections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB Port\u003c\/td\u003e\n\u003ctd\u003eFront-access USB port for local configuration and Studio 5000 access\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSD Card Slot\u003c\/td\u003e\n\u003ctd\u003eMemory card slot supporting industrial SD card for non-volatile project backup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Verification\u003c\/strong\u003e: Ensure the mounting enclosure provides an open-type rating suitable for Pollution Degree 2 environments and ambient operation between 0 degC and 60 degC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Mounting\u003c\/strong\u003e: Mount a zinc-plated chromate steel DIN rail horizontally. Verify that the DIN rail is securely grounded to the enclosure frame backplate.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eController Placement\u003c\/strong\u003e: Position the 5069-L330ERMS3 as the leftmost module on the DIN rail. Press firmly onto the DIN rail until the latches click into place.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocal I\/O \u0026amp; End Cap\u003c\/strong\u003e: Install any local Compact 5000 I\/O modules to the right of the controller. Ensure the rightmost module is fitted with the 5069 terminal end cap to protect the exposed module bus connectors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Wiring\u003c\/strong\u003e: Wire the 5069-RTB4 (MOD) and 5069-RTB6 (SA) removable terminal blocks using SELV\/PELV power supplies. Tighten screw terminals to 0.4 Nm torque. Ensure power supplies are powered off before inserting terminal blocks into the controller.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Connectivity\u003c\/strong\u003e: Connect standard shielded RJ45 Ethernet cables to the gigabit Ethernet ports.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eConfiguration and Commissioning Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eInitial IP Assignment\u003c\/strong\u003e: Connect a PC to the controller via the front panel USB port or use the EtherNet\/IP BOOTP-DHCP Server utility (version 3.02.00 or later) \/ RSLinx Classic (version 4.10.00 or later) to allocate an initial IP address.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMode Selection\u003c\/strong\u003e: Choose between Dual-IP mode (independent IP addresses per port for enterprise\/control layer isolation) or Linear\/DLR mode within RSLinx Classic or Studio 5000 Logix Designer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Logic Programming\u003c\/strong\u003e: Open Studio 5000 Logix Designer (version 32 or later). Create a project selecting model 5069-L330ERMS3. Configure safety task signatures, safety network numbers (SNN), and safe motion profiles according to functional safety requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Verification \u0026amp; Backup\u003c\/strong\u003e: Perform mandatory safety system validation checks. Once commissioned, transfer the verified application binary and safety signature to the industrial SD card for non-volatile storage.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eReplacement Recommendations\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Isolation\u003c\/strong\u003e: Turn off external MOD power and SA power supplies before attempting replacement. \u003cstrong\u003eCaution\u003c\/strong\u003e: The controller does not support Removal and Insertion Under Power (RIUP). Removing the controller under power will cause arc flash hazards and interrupt the local module bus.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Disconnection\u003c\/strong\u003e: Release the handles on the 5069-RTB4 and 5069-RTB6 removable terminal blocks and pull them out without disturbing field wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHardware Swapping\u003c\/strong\u003e: Unclip Ethernet cables, pull the latch mechanisms downward, and remove the original unit from the DIN rail. Install the replacement 5069-L330ERMS3 controller.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRestoration\u003c\/strong\u003e: Reinsert terminal blocks and network cables. Apply MOD and SA power. Restore project logic and safety parameters via Studio 5000 Logix Designer or automatically load the project from the pre-existing SD memory card.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunctional Safety\u003c\/strong\u003e: Certified Cat. 4 \/ PL e (EN ISO 13849-1) and SIL 3 \/ SILCL 3 (EN 62061 \/ IEC 61508)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEuropean Machinery Directive\u003c\/strong\u003e: Compliant with 2006\/42\/EC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Locations\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003eNorth America: Class I, Division 2, Groups A, B, C, D\u003c\/li\u003e\n\u003cli\u003eATEX: II 3 G Ex nA IIC T4 Gc (DEMKO19ATEX2261X)\u003c\/li\u003e\n\u003cli\u003eIECEx: Ex nA IIC T4 Gc (IECEx UL 19.0081X)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE Compliance\u003c\/strong\u003e: Compliant with European Directives\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":53724085780843,"sku":"5069-L330ERMS3","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/5069-L330ERMS3_002_1200x1200_b7706f82-4b50-49ed-9ad3-bc2df020470d.jpg?v=1786713448","url":"https:\/\/www.plcprotech.com\/it\/products\/allen-bradley-5069-l330erms3-compact-guardlogix-5380-sil3-safety-controller","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}