{"product_id":"beckhoff-cx1500-m310-profibus-master-fieldbus-connection","title":"BECKHOFF CX1500-M310 PROFIBUS Master Fieldbus Connection","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe BECKHOFF CX1500-M310 is a PROFIBUS master fieldbus connection designed for integration with the CX series Embedded PC system architecture. This hardware module enables the controller to operate as a PROFIBUS master, facilitating deterministic communication with distributed field devices, sensors, and actuators in industrial automation environments.\u003c\/p\u003e\n\u003cp\u003eThe module interfaces directly with the CPU via an ISA plug and play connection utilizing 2 kbytes of DPRAM. It supports PROFIBUS DP, DP-V1, and DP-V2 (MC) communication protocols, allowing flexible data exchange, parameterization, and diagnostic handling for complex machine control topologies.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003ePROFIBUS DP, DP-V1, and DP-V2 (MC) master functionality\u003c\/li\u003e\n  \u003cli\u003eData transfer rates ranging from 9.6 kbaud to 12 Mbaud\u003c\/li\u003e\n  \u003cli\u003eSupports up to 125 PROFIBUS slaves with up to 244 bytes of input, output, parameter, configuration, or diagnostic data per slave\u003c\/li\u003e\n  \u003cli\u003eConfigurable DP cycle times for individual slaves\u003c\/li\u003e\n  \u003cli\u003eFreely configurable error management for each network participant\u003c\/li\u003e\n  \u003cli\u003eSingle 9-pin D-sub socket bus interface\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eIndustrial machinery and automated manufacturing lines utilizing PROFIBUS fieldbus networks\u003c\/li\u003e\n  \u003cli\u003eDistributed control architectures connected to BECKHOFF CX series Embedded PCs\u003c\/li\u003e\n  \u003cli\u003eProcess and factory automation systems requiring master-level communication with decentralized slave devices\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBECKHOFF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eExact Model\u003c\/td\u003e\n      \u003ctd\u003eCX1500-M310\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003ePROFIBUS Master Fieldbus Connection\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFieldbus\u003c\/td\u003e\n      \u003ctd\u003ePROFIBUS DP, DP-V1, DP-V2 (MC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eData Transfer Rates\u003c\/td\u003e\n      \u003ctd\u003e9.6 kbaud to 12 Mbaud\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBus Interface\u003c\/td\u003e\n      \u003ctd\u003e1 x D-sub socket, 9-pin\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMax. Number of Slaves\u003c\/td\u003e\n      \u003ctd\u003e125 slaves\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eData per Slave\u003c\/td\u003e\n      \u003ctd\u003eMax. 244 bytes input, output, parameter, configuration, or diagnostic data\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInterface to CPU\u003c\/td\u003e\n      \u003ctd\u003eISA plug and play, 2 kbytes DPRAM\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMax. Power Loss\u003c\/td\u003e\n      \u003ctd\u003e1.8 W\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSoftware Compatibility\u003c\/td\u003e\n      \u003ctd\u003eTwinCAT 2\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n      \u003ctd\u003e38 mm x 100 mm x 91 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eWeight\u003c\/td\u003e\n      \u003ctd\u003eApprox. 190 g\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n      \u003ctd\u003e0 to +55 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStorage Temperature Range\u003c\/td\u003e\n      \u003ctd\u003e-25 to +85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRelative Humidity\u003c\/td\u003e\n      \u003ctd\u003e95 %, no condensation\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eVibration\/Shock Resistance\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 60068-2-6 \/ EN 60068-2-27\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEMC Immunity\/Emission\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 61000-6-2 \/ EN 61000-6-4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProtection Rating\u003c\/td\u003e\n      \u003ctd\u003eIP20\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eApprovals\/Markings\u003c\/td\u003e\n      \u003ctd\u003eCE, UL\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eInterface\u003c\/th\u003e\n      \u003cth\u003eFunction\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e9-pin D-sub socket\u003c\/td\u003e\n      \u003ctd\u003ePROFIBUS master communication interface\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eISA plug and play connector\u003c\/td\u003e\n      \u003ctd\u003eInternal connection and data exchange with the CPU via DPRAM\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eEnsure the entire control system is fully de-energized before mounting or removing the CX1500-M310 module.\u003c\/li\u003e\n  \u003cli\u003eInspect the hardware interface and pins for any signs of damage or contamination.\u003c\/li\u003e\n  \u003cli\u003eAttach the module securely to the designated slot on the compatible BECKHOFF CX series Embedded PC, ensuring proper alignment with the internal ISA interface.\u003c\/li\u003e\n  \u003cli\u003eConnect the PROFIBUS network cable to the 9-pin D-sub socket, applying proper shielding and grounding practices.\u003c\/li\u003e\n  \u003cli\u003eVerify all wiring, power supplies, and network terminations before restoring power to the system.\u003c\/li\u003e\n  \u003cli\u003eConfigure the PROFIBUS network parameters and slave devices within the TwinCAT engineering environment prior to commissioning.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106451120491,"sku":"CX1500-M310","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/cx1500-m310-dpn15iw415q.png?v=1776244155","url":"https:\/\/www.plcprotech.com\/it\/products\/beckhoff-cx1500-m310-profibus-master-fieldbus-connection","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}