{"product_id":"beckhoff-epp1008-0002-ethercat-p-box","title":"BECKHOFF EPP1008-0002 EtherCAT P Box","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe BECKHOFF EPP1008-0002 is an 8-channel digital input EtherCAT P Box designed to acquire binary control signals from the physical process level. This industrial I\/O block is engineered to transmit data and control signals directly to the controller via a highly efficient EtherCAT P connection, which combines high-speed communication and power distribution (Us and Up) into a single, standardized 4-wire cable.\u003c\/p\u003e\n\u003cp\u003eHoused in a compact, durable polyamide shell, the BECKHOFF EPP1008-0002 is built for direct machine integration. By removing the need for a protective control cabinet, this device minimizes field-level wiring distances, lowers system installation overhead, and simplifies layout expansion in complex automation projects.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eEight digital inputs with 24 V DC nominal voltage rating\u003c\/li\u003e\n  \u003cli\u003eEtherCAT P interface utilizing two P-coded M8 screw-type connectors for combined data and power transmission\u003c\/li\u003e\n  \u003cli\u003eFive-pin, A-coded M12 screw-type input connection points\u003c\/li\u003e\n  \u003cli\u003eIntegrated 3.0 ms input filter to suppress signal bouncing and electrical noise\u003c\/li\u003e\n  \u003cli\u003eSensor power supply derived directly from the control voltage (Us)\u003c\/li\u003e\n  \u003cli\u003eShort-circuit proof sensor supply up to 0.5 A in total\u003c\/li\u003e\n  \u003cli\u003eHigh environmental protection rating suitable for direct machine mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDecentralized input acquisition without control cabinets\u003c\/li\u003e\n  \u003cli\u003eMachine tool, assembly, and material handling systems\u003c\/li\u003e\n  \u003cli\u003eConveyor systems and robotic cell monitoring\u003c\/li\u003e\n  \u003cli\u003eDamp, dusty, or high-vibration industrial field environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBECKHOFF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eExact Model\u003c\/td\u003e\n      \u003ctd\u003eEPP1008-0002\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003eEtherCAT P Box (Digital Input)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProtocol\u003c\/td\u003e\n      \u003ctd\u003eEtherCAT P\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNumber of Inputs\u003c\/td\u003e\n      \u003ctd\u003e8\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBus Interface\u003c\/td\u003e\n      \u003ctd\u003e2 x M8 socket, shielded, screw type, P-coded\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInput Connection Type\u003c\/td\u003e\n      \u003ctd\u003eM12, 5-pin, A-coded\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n      \u003ctd\u003e24 V DC (-15% \/ +20%)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInput Filter Time\u003c\/td\u003e\n      \u003ctd\u003e3.0 ms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSignal Voltage \"0\"\u003c\/td\u003e\n      \u003ctd\u003e-3 to +5 V (conforms to EN 61131-2, type 3)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSignal Voltage \"1\"\u003c\/td\u003e\n      \u003ctd\u003e11 to 30 V (conforms to EN 61131-2, type 3)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInput Current\u003c\/td\u003e\n      \u003ctd\u003etyp. 3 mA (conforms to EN 61131-2, type 3)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDistributed Clocks\u003c\/td\u003e\n      \u003ctd\u003eNo\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSensor Supply\u003c\/td\u003e\n      \u003ctd\u003eFrom control voltage Us, max. 0.5 A total, short-circuit proof\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCurrent Consumption from Us\u003c\/td\u003e\n      \u003ctd\u003etyp. 100 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eHousing Material\u003c\/td\u003e\n      \u003ctd\u003ePA6 (polyamide)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n      \u003ctd\u003e30 mm x 126 mm x 26.5 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eWeight\u003c\/td\u003e\n      \u003ctd\u003eapprox. 165 g\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd\u003e-25 to +60 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStorage Temperature\u003c\/td\u003e\n      \u003ctd\u003e-40 to +85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProtection Rating\u003c\/td\u003e\n      \u003ctd\u003eIP65 \/ IP66 \/ IP67 (conforms to EN 60529)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eVibration\/Shock Resistance\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 60068-2-6 \/ EN 60068-2-27\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEMC Immunity\/Emission\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 61000-6-2 \/ EN 61000-6-4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eApprovals\u003c\/td\u003e\n      \u003ctd\u003eCE, UL\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eVerify the system layout and check that the BECKHOFF EPP1008-0002 matches the plan specifications.\u003c\/li\u003e\n  \u003cli\u003eDe-energize all field power supplies before mounting or connecting wires.\u003c\/li\u003e\n  \u003cli\u003eMount the unit on a flat machine surface using two 3.5 mm diameter fixing holes suitable for M3 screws.\u003c\/li\u003e\n  \u003cli\u003eConnect the incoming and outgoing EtherCAT P lines using shielded, P-coded M8 cables. Tighten the screw connectors securely to maintain the IP protection rating.\u003c\/li\u003e\n  \u003cli\u003eWire sensors to the 5-pin, A-coded M12 sockets according to standard pin assignments. Ensure unused sockets are sealed with protective caps to prevent moisture ingress.\u003c\/li\u003e\n  \u003cli\u003ePower up the control system and configure the node in the TwinCAT engineering environment.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106561843563,"sku":"EPP1008-0002","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/epp1008-0002-eptqshbqzfj.png?v=1776244710","url":"https:\/\/www.plcprotech.com\/it\/products\/beckhoff-epp1008-0002-ethercat-p-box","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}