{"product_id":"beckhoff-epp1819-0022-ethercat-p-box","title":"BECKHOFF EPP1819-0022 EtherCAT P Box","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe BECKHOFF EPP1819-0022 is an EtherCAT P Box designed for decentralized industrial automation networks. This module functions as a digital input device featuring 16 channels, engineered to acquire binary control signals from industrial sensors and switches in harsh shop-floor environments. It connects directly to the high-speed EtherCAT P communication and power infrastructure, integrating input data acquisition while streamlining cabling architecture through its combined bus and supply line.\u003c\/p\u003e\n\u003cp\u003eEquipped with a ruggedized housing, the EPP1819-0022 maintains high protection ratings against dust, moisture, and mechanical stress. It serves machine builders and system integrators requiring decentralized signal collection without the necessity of control cabinet enclosures.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e16 digital inputs compliant with EN 61131-2, type 1\/3 specifications\u003c\/li\u003e\n  \u003cli\u003eEtherCAT P communication interface with 2 M8 sockets, shielded, screw type, P-coded\u003c\/li\u003e\n  \u003cli\u003eM12 x 1, 5-pin, A-coded connection technology for input channels\u003c\/li\u003e\n  \u003cli\u003eSensor supply sourced from control voltage with short-circuit protection\u003c\/li\u003e\n  \u003cli\u003eDesigned for direct machine mounting in IP65, IP66, and IP67 rated environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDecentralized machine automation and modular plant engineering\u003c\/li\u003e\n  \u003cli\u003eAutomated assembly lines and material handling equipment\u003c\/li\u003e\n  \u003cli\u003eConveyor systems and packaging machinery requiring cabinet-free I\/O distribution\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBECKHOFF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eExact Model\u003c\/td\u003e\n      \u003ctd\u003eEPP1819-0022\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003eEtherCAT P Box\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProtocol\u003c\/td\u003e\n      \u003ctd\u003eEtherCAT\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBus Interface\u003c\/td\u003e\n      \u003ctd\u003e2 x M8 socket, shielded, screw type, P-coded\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNumber of Inputs\u003c\/td\u003e\n      \u003ctd\u003e16\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInput Connections\u003c\/td\u003e\n      \u003ctd\u003eM12 x 1, 5-pin, A-coded\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n      \u003ctd\u003e24 V DC (-15 % \/ +20 %)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInput Filter\u003c\/td\u003e\n      \u003ctd\u003e10 us\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSignal Voltage \"0\"\u003c\/td\u003e\n      \u003ctd\u003e-3 to +5 V (EN 61131-2, type 3)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSignal Voltage \"1\"\u003c\/td\u003e\n      \u003ctd\u003e11 to 30 V (EN 61131-2, type 3)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInput Current\u003c\/td\u003e\n      \u003ctd\u003eTyp. 3 mA (EN 61131-2, type 3)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSensor Supply\u003c\/td\u003e\n      \u003ctd\u003eFrom control voltage, max. 0.5 A total, short-circuit proof\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCurrent Consumption from US\u003c\/td\u003e\n      \u003ctd\u003eTyp. 100 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eElectrical Isolation\u003c\/td\u003e\n      \u003ctd\u003e500 V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProtection Rating\u003c\/td\u003e\n      \u003ctd\u003eIP65 \/ IP66 \/ IP67 (conforms to EN 60529)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd\u003e-25 to +60 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStorage Temperature\u003c\/td\u003e\n      \u003ctd\u003e-40 to +85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eVibration \/ Shock Resistance\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 60068-2-6 \/ EN 60068-2-27\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEMC Immunity \/ Emission\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 61000-6-2 \/ EN 61000-6-4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInstallation Position\u003c\/td\u003e\n      \u003ctd\u003eVariable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eApprovals \/ Markings\u003c\/td\u003e\n      \u003ctd\u003eCE, UL\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eInterface\u003c\/th\u003e\n      \u003cth\u003eFunction\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e2 x M8 Socket (P-coded)\u003c\/td\u003e\n      \u003ctd\u003eEtherCAT P input and output \/ daisy chain connection\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eM12 x 1 Sockets (5-pin, A-coded)\u003c\/td\u003e\n      \u003ctd\u003eDigital signal inputs (Channels 0 to 15) and sensor power supply\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eEnsure the system is completely de-energized before mounting or wiring the module.\u003c\/li\u003e\n  \u003cli\u003eInspect the EPP1819-0022 housing, seals, and interface connectors for any signs of transit damage.\u003c\/li\u003e\n  \u003cli\u003eMount the box securely to a flat machine surface or mounting plate using appropriate fastening hardware.\u003c\/li\u003e\n  \u003cli\u003eConnect the incoming and outgoing EtherCAT P cables to the M8 P-coded bus interfaces.\u003c\/li\u003e\n  \u003cli\u003eConnect field sensors to the M12 A-coded input sockets, ensuring correct pin assignment and torque limits.\u003c\/li\u003e\n  \u003cli\u003eVerify all cable shields and ground connections to maintain EMC performance.\u003c\/li\u003e\n  \u003cli\u003ePower on the control system and verify communication status via the diagnostic LEDs prior to commissioning.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106528256363,"sku":"EPP1819-0022","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/epp1819-0022-ytidhqlq5t4.png?v=1776244725","url":"https:\/\/www.plcprotech.com\/it\/products\/beckhoff-epp1819-0022-ethercat-p-box","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}