{"product_id":"beckhoff-il2301-c310-plc-box","title":"BECKHOFF IL2301-C310 PLC Box","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe BECKHOFF IL2301-C310 is a PLC Box designed for decentralized automation tasks in industrial environments without the need for a control cabinet. Functioning as a compact programmable control device, this unit integrates processing capability directly into the machine-level architecture, allowing local data pre-processing and control execution close to sensors and actuators. It connects into a PROFIBUS DP network via an integrated bus interface and supports DP-V1 extensions for flexible configuration and parameterization.\u003c\/p\u003e\n\u003cp\u003eEquipped with robust M-style connectors for communication, power supply, and field connections, the IL2301-C310 is engineered for harsh floor-level conditions, featuring a high protection rating that guards against dust and moisture ingress. It operates on a standard 24 V DC control voltage supply and provides automated data transfer rate detection up to 12 Mbaud to integrate efficiently into existing PROFIBUS architectures.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDecentralized PLC functionality designed for machine-level installation without a control cabinet\u003c\/li\u003e\n  \u003cli\u003eIntegrated PROFIBUS DP interface with automatic baud rate detection up to 12 Mbaud\u003c\/li\u003e\n  \u003cli\u003eSupport for DP-V1 extensions for enhanced configuration and diagnostics\u003c\/li\u003e\n  \u003cli\u003eRugged IP65, IP66, and IP67 protected housing suitable for demanding industrial settings\u003c\/li\u003e\n  \u003cli\u003eM8 and M12 connection technology for secure, tool-managed cabling\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDecentralized machine control and data pre-processing\u003c\/li\u003e\n  \u003cli\u003eModular assembly systems and conveyor lines\u003c\/li\u003e\n  \u003cli\u003eDistributed packaging and material handling machinery\u003c\/li\u003e\n  \u003cli\u003eIndustrial automation environments utilizing PROFIBUS DP networks\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBECKHOFF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eExact Model\u003c\/td\u003e\n      \u003ctd\u003eIL2301-C310\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003ePLC Box\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eCommunication\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBus Interface\u003c\/td\u003e\n      \u003ctd\u003e1 x M12 socket, 5-pin, B-coded\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eData Transfer Rates\u003c\/td\u003e\n      \u003ctd\u003eAutomatic detection up to 12 Mbaud\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConfiguration Possibility\u003c\/td\u003e\n      \u003ctd\u003eVia KS2000 or the controller, DP-V1 extensions supported\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eElectrical\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eControl Voltage Power Supply\u003c\/td\u003e\n      \u003ctd\u003e24 V DC (-15 %\/+20 %)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLoad Voltage Power Supply\u003c\/td\u003e\n      \u003ctd\u003eAccording to I\/O type\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Supply Connection\u003c\/td\u003e\n      \u003ctd\u003eFeed: 1 x M8 male socket, 4-pin; Downstream connection: 1 x M8 female socket, 4-pin\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBox Supply Current\u003c\/td\u003e\n      \u003ctd\u003e85 mA + current consumption of sensors, max. 0.5 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eAuxiliary Power Current\u003c\/td\u003e\n      \u003ctd\u003eAccording to I\/O type\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eElectrical Isolation\u003c\/td\u003e\n      \u003ctd\u003eControl voltage\/fieldbus: No, Control voltage\/inputs or outputs: According to I\/O type\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eEnvironmental and Mechanical\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n      \u003ctd\u003e0 to +55 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStorage Temperature Range\u003c\/td\u003e\n      \u003ctd\u003e-25 to +85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eVibration Resistance\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 60068-2-6\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eShock Resistance\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 60068-2-27\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEMC Immunity\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 61000-6-2\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEMC Emission\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 61000-6-4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProtection Rating\u003c\/td\u003e\n      \u003ctd\u003eIP65 \/ IP66 \/ IP67 (conforms to EN 60529)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInstallation Position\u003c\/td\u003e\n      \u003ctd\u003eVariable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eApprovals and Markings\u003c\/td\u003e\n      \u003ctd\u003eCE, UL\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eInterface\u003c\/th\u003e\n      \u003cth\u003eFunction\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e1 x M12 Socket (5-pin, B-coded)\u003c\/td\u003e\n      \u003ctd\u003ePROFIBUS DP bus interface\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e1 x M8 Male Socket (4-pin)\u003c\/td\u003e\n      \u003ctd\u003ePower supply feed\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e1 x M8 Female Socket (4-pin)\u003c\/td\u003e\n      \u003ctd\u003ePower supply downstream connection\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eEnsure all power sources feeding the control voltage and field supplies are switched off and locked out before beginning installation.\u003c\/li\u003e\n  \u003cli\u003eInspect the unit and connectors for any visible signs of damage or contamination.\u003c\/li\u003e\n  \u003cli\u003eMount the PLC Box securely in a variable position suitable for the machine layout, ensuring adequate clearance for connected M-coded cables.\u003c\/li\u003e\n  \u003cli\u003eConnect the 24 V DC control voltage feed to the designated M8 male socket and daisy-chain downstream power if required using the M8 female socket.\u003c\/li\u003e\n  \u003cli\u003eAttach the PROFIBUS DP network cable to the 5-pin B-coded M12 socket.\u003c\/li\u003e\n  \u003cli\u003eVerify that all field-side connections, sensor lines, and potential assignments comply with the exact specification requirements before restoring power.\u003c\/li\u003e\n  \u003cli\u003eCommission the system by configuring the device parameters via the controller or KS2000 software interface.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106427986283,"sku":"IL2301-C310","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/il2301-c310-ypgxj4hl01h.png?v=1776244848","url":"https:\/\/www.plcprotech.com\/it\/products\/beckhoff-il2301-c310-plc-box","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}