{"product_id":"beckhoff-ip1000-b730-fieldbus-box","title":"BECKHOFF IP1000-B730 Fieldbus Box","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBECKHOFF IP1000-B730\u003c\/strong\u003e is a Modbus RTU\/ASCII Fieldbus Box designed to act as a decentralized interface in demanding industrial automation environments. This compact module enables reliable communication and integration of field devices into Modbus serial networks, ensuring steady operation and high environmental durability. Built to survive challenging field conditions, it features a fully sealed design that facilitates direct machine mounting without the need for an additional protective enclosure.\u003c\/p\u003e\n\u003cp\u003eBy shifting the communication interface directly into the field, the \u003cstrong\u003eBECKHOFF IP1000-B730\u003c\/strong\u003e minimizes wiring overhead and simplifies distributed machine architectures. It offers configuration options via onboard address selection switches or specialized configuration software, providing flexibility during commissioning and system integration.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eProtocol support for Modbus RTU and Modbus ASCII standards.\u003c\/li\u003e\n  \u003cli\u003eFlexible address configuration using integrated physical rotary switches or the KS2000 software tool.\u003c\/li\u003e\n  \u003cli\u003eWide range of supported serial data transfer rates from 150 to 38,400 baud.\u003c\/li\u003e\n  \u003cli\u003eStandardized M12 fieldbus interface with secure B-coding.\u003c\/li\u003e\n  \u003cli\u003eM8 power supply connection system featuring feed and downstream daisy-chain capability.\u003c\/li\u003e\n  \u003cli\u003eElectrical isolation between the control voltage and the fieldbus interface for enhanced noise immunity.\u003c\/li\u003e\n  \u003cli\u003eHigh protection rating of IP65\/66\/67, permitting direct mounting in wet, dusty, or harsh industrial environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDecentralized machine control and distributed I\/O network architectures.\u003c\/li\u003e\n  \u003cli\u003eField-level sensor and actuator communication using Modbus serial communication.\u003c\/li\u003e\n  \u003cli\u003eIn-the-field installations requiring robust environmental protection without control cabinets.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBECKHOFF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModel\u003c\/td\u003e\n      \u003ctd\u003eIP1000-B730\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003eFieldbus Box\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eCommunication \u0026amp; Configuration\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProtocol\u003c\/td\u003e\n      \u003ctd\u003eModbus RTU \/ Modbus ASCII\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eData Transfer Rates\u003c\/td\u003e\n      \u003ctd\u003e150, 300, 600, 1200, 2400, 4800, 9600, 19,200, 38,400 baud\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConfiguration Method\u003c\/td\u003e\n      \u003ctd\u003eAddress selection switch or KS2000 software\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBus Interface\u003c\/td\u003e\n      \u003ctd\u003e1 x M12 socket, 5-pin, B-coded\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eElectrical Data\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eControl Voltage\u003c\/td\u003e\n      \u003ctd\u003e24 V DC (-15% \/ +20%)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Supply Connection\u003c\/td\u003e\n      \u003ctd\u003eFeed: 1 x M8 male socket (4-pin); Downstream: 1 x M8 female socket (4-pin)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBox Supply Current\u003c\/td\u003e\n      \u003ctd\u003e45 mA + sensor current consumption (max. 0.5 A)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eElectrical Isolation\u003c\/td\u003e\n      \u003ctd\u003eControl voltage to fieldbus: Yes\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eMechanical \u0026amp; Environmental\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eWeight\u003c\/td\u003e\n      \u003ctd\u003eApprox. 210 g\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd\u003e0 degC to +55 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStorage Temperature\u003c\/td\u003e\n      \u003ctd\u003e-25 degC to +85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eIngress Protection\u003c\/td\u003e\n      \u003ctd\u003eIP65 \/ IP66 \/ IP67 (conforms to EN 60529)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eVibration \u0026amp; Shock Resistance\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 60068-2-6 \/ EN 60068-2-27\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEMC Immunity \u0026amp; Emission\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 61000-6-2 \/ EN 61000-6-4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eApprovals \u0026amp; Markings\u003c\/td\u003e\n      \u003ctd\u003eCE, UL\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eVerify that the system power supply is completely de-energized before beginning installation of the \u003cstrong\u003eBECKHOFF IP1000-B730\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003eMount the Fieldbus Box securely to a flat mounting surface using appropriate fastening screws to ensure mechanical stability.\u003c\/li\u003e\n  \u003cli\u003eSet the required Modbus node address using the integrated address selection switches or prepare the unit for KS2000 software configuration.\u003c\/li\u003e\n  \u003cli\u003eConnect the 24 V DC control voltage supply to the 4-pin M8 male feed socket, paying close attention to correct pin alignment.\u003c\/li\u003e\n  \u003cli\u003eAttach the Modbus RTU\/ASCII network cable to the 5-pin B-coded M12 socket connector.\u003c\/li\u003e\n  \u003cli\u003eSeal any unused M8 or M12 connector ports with matching protective caps to preserve the IP65\/IP66\/IP67 environmental protection rating.\u003c\/li\u003e\n  \u003cli\u003eRe-energize the system and verify communication and device operation using the diagnostic indicators.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106528715115,"sku":"IP1000-B730","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ip1000-b730-c3l0aknxpv0.png?v=1776244859","url":"https:\/\/www.plcprotech.com\/it\/products\/beckhoff-ip1000-b730-fieldbus-box","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}