{"product_id":"beckhoff-ip1001-b310-fieldbus-box","title":"BECKHOFF IP1001-B310 Fieldbus Box","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBECKHOFF IP1001-B310\u003c\/strong\u003e is a decentralized Fieldbus Box designed to acquisition digital input signals directly in the field, bypassing the need for an industrial control cabinet. Engineered for direct machine mounting, this high-durability module connects up to eight digital sensors to a master controller via a PROFIBUS DP interface.\u003c\/p\u003e\n\u003cp\u003eThis module features space-saving M8 connection technology for standard sensors alongside robust power distribution and diagnostic capabilities. By placing the I\/O interface directly on the equipment, the module reduces wiring overhead and installation complexity in industrial automation systems.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eEight digital input channels for 24 V DC sensor signals.\u003c\/li\u003e\n  \u003cli\u003eIntegrated PROFIBUS DP interface supporting automatic baud rate detection.\u003c\/li\u003e\n  \u003cli\u003eDecentralized IP67 protection rating for enclosure-free field deployment.\u003c\/li\u003e\n  \u003cli\u003eInput signal filtering of 3 ms to prevent signal bounce and transient errors.\u003c\/li\u003e\n  \u003cli\u003eM8 connectors for compact, reliable sensor signal connections.\u003c\/li\u003e\n  \u003cli\u003eM12 fieldbus interface for secure industrial communication.\u003c\/li\u003e\n  \u003cli\u003ePower routing via dedicated M8 input feed and downstream loop-through connections.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCabinet-free machine architecture and decentralized automation setups.\u003c\/li\u003e\n  \u003cli\u003eMaterial handling, logistics, and conveyor lines.\u003c\/li\u003e\n  \u003cli\u003ePackaging, assembly, and industrial production plants.\u003c\/li\u003e\n  \u003cli\u003eDistributed sensor networks operating under standard PROFIBUS DP protocols.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBECKHOFF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModel\u003c\/td\u003e\n      \u003ctd\u003eIP1001-B310\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003eFieldbus Box\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eSignal and I\/O\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNumber of Inputs\u003c\/td\u003e\n      \u003ctd\u003e8 digital inputs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n      \u003ctd\u003e24 V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInput Filter Time\u003c\/td\u003e\n      \u003ctd\u003e3 ms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConnection Technology\u003c\/td\u003e\n      \u003ctd\u003eM8 screw-type\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eFieldbus and Communication\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProtocol\u003c\/td\u003e\n      \u003ctd\u003ePROFIBUS DP (DP-V1 supported)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eData Transfer Rates\u003c\/td\u003e\n      \u003ctd\u003eAutomatic detection up to 12 Mbaud\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBus Interface\u003c\/td\u003e\n      \u003ctd\u003e1 x M12 socket, 5-pin, B-coded\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConfiguration Options\u003c\/td\u003e\n      \u003ctd\u003eVia KS2000 software or master controller\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eElectrical\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eControl Voltage\u003c\/td\u003e\n      \u003ctd\u003e24 V DC (-15% \/ +20%)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Supply Connection\u003c\/td\u003e\n      \u003ctd\u003eFeed: 1 x M8 male, 4-pin; Downstream: 1 x M8 female, 4-pin\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBox Supply Current\u003c\/td\u003e\n      \u003ctd\u003e85 mA + sensor current consumption (max. 0.5 A)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eMechanical and Environmental\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProtection Class\u003c\/td\u003e\n      \u003ctd\u003eIP65, IP66, IP67 (conforms to EN 60529)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd\u003e0 to +55 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStorage Temperature\u003c\/td\u003e\n      \u003ctd\u003e-25 to +85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eVibration\/Shock Resistance\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 60068-2-6 \/ EN 60068-2-27\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEMC Immunity\/Emission\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 61000-6-2 \/ EN 61000-6-4\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eEnsure all electrical supplies are fully de-energized and locked out before starting installation.\u003c\/li\u003e\n  \u003cli\u003eSecure the module to the machine frame using appropriate mounting holes on the housing.\u003c\/li\u003e\n  \u003cli\u003eConnect the PROFIBUS DP network cable to the B-coded M12 fieldbus socket.\u003c\/li\u003e\n  \u003cli\u003eConnect the 24 V DC control voltage to the M8 male feed socket. If linking multiple modules, connect the downstream M8 cable to the next device.\u003c\/li\u003e\n  \u003cli\u003ePlug the 24 V DC sensors into the 8 x M8 input sockets, making sure all connections are securely tightened to maintain the IP67 environmental seal.\u003c\/li\u003e\n  \u003cli\u003eApply power and inspect the integrated status LEDs for correct network and device diagnosis.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106471993707,"sku":"IP1001-B310","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ip1001-b310-g32yr3lad3y.png?v=1776244862","url":"https:\/\/www.plcprotech.com\/it\/products\/beckhoff-ip1001-b310-fieldbus-box","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}