{"product_id":"beckhoff-ip1001-b400-interbus-fieldbus-box","title":"BECKHOFF IP1001-B400 Interbus Fieldbus Box","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBECKHOFF IP1001-B400\u003c\/strong\u003e is a high-performance, decentralized Interbus Fieldbus Box designed to interface 8 digital inputs directly with an Interbus network. Engineered for direct machine-level installation, this robust module eliminates the need for protective control enclosures, enabling distributed control topologies in space-constrained or harsh manufacturing environments.\u003c\/p\u003e\n\n\u003cp\u003eThis module features 8 independent digital input channels operating at a nominal 24 V DC voltage level. An integrated 3 ms hardware input filter stabilizes signals, ensuring reliable operation when interfacing with mechanical switches, proximity sensors, or other standard digital field devices. Input signals are connected using robust, space-saving M8 circular connectors to withstand intense industrial vibration.\u003c\/p\u003e\n\n\u003cp\u003eFieldbus communication for the \u003cstrong\u003eBECKHOFF IP1001-B400\u003c\/strong\u003e is routed through standardized M23 connection ports, offering direct IN and OUT loop capabilities for easy system daisy-chaining. The modular power architecture separates control voltage from the sensor power feed, providing simplified electrical grouping and enhanced diagnostic isolation across the machine footprint.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e8 digital input channels optimized for 24 V DC field signals\u003c\/li\u003e\n  \u003cli\u003eInterbus system connection via 1 x male and 1 x female 9-pin M23 connectors\u003c\/li\u003e\n  \u003cli\u003eIntegrated 3 ms input filter for noise suppression and signal stabilization\u003c\/li\u003e\n  \u003cli\u003eCompact M8 screw-type connection technology for individual digital sensors\u003c\/li\u003e\n  \u003cli\u003eHigh-density IP65\/66\/67 environmental protection rating\u003c\/li\u003e\n  \u003cli\u003eSeparate control voltage and sensor power routing to maximize diagnostic grouping\u003c\/li\u003e\n  \u003cli\u003eDevice configuration and parameter setup support via KS2000 software\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDecentralized input mapping in Interbus-controlled assembly lines\u003c\/li\u003e\n  \u003cli\u003eField-level signal acquisition on material handling conveyor systems\u003c\/li\u003e\n  \u003cli\u003eDirect machine-mount sensor integration in packaging and processing machinery\u003c\/li\u003e\n  \u003cli\u003eDistributed IO architectures exposed to moisture, dust, and mechanical vibration\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth colspan=\"2\"\u003eGeneral Data\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBECKHOFF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModel\u003c\/td\u003e\n      \u003ctd\u003eIP1001-B400\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003eFieldbus Box (Digital Input)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFieldbus Protocol\u003c\/td\u003e\n      \u003ctd\u003eInterbus\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eSignal and I\/O Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNumber of Inputs\u003c\/td\u003e\n      \u003ctd\u003e8 digital inputs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n      \u003ctd\u003e24 V DC (-15% \/ +20%)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInput Filter Time\u003c\/td\u003e\n      \u003ctd\u003e3 ms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSensor Connection\u003c\/td\u003e\n      \u003ctd\u003e8 x M8 female sockets, 3-pin\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eElectrical Data\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eControl Voltage\u003c\/td\u003e\n      \u003ctd\u003e24 V DC (20...29 V DC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBox Current Consumption\u003c\/td\u003e\n      \u003ctd\u003e85 mA + sensor current (max. 0.5 A total)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eElectrical Isolation\u003c\/td\u003e\n      \u003ctd\u003eControl voltage\/fieldbus: No; Control voltage\/inputs: No (common ground)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Supply Connection\u003c\/td\u003e\n      \u003ctd\u003eFeed: 1 x M8 male, 4-pin; Downstream: 1 x M8 female, 4-pin\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eMechanical and Environmental\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n      \u003ctd\u003eapprox. 30 mm x 175 mm x 26.5 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eWeight\u003c\/td\u003e\n      \u003ctd\u003eapprox. 350 g\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProtection Class\u003c\/td\u003e\n      \u003ctd\u003eIP65\/66\/67 (conforms to EN 60529)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n      \u003ctd\u003e0 degC to +55 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStorage Temperature Range\u003c\/td\u003e\n      \u003ctd\u003e-25 degC to +85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eVibration\/Shock Resistance\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 60068-2-6 \/ EN 60068-2-27\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEMC Immunity\/Emission\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 61000-6-2 \/ EN 61000-6-4\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eInterface Port\u003c\/th\u003e\n      \u003cth\u003eConnection Type\u003c\/th\u003e\n      \u003cth\u003eFunction\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInterbus IN\u003c\/td\u003e\n      \u003ctd\u003e9-pin M23 male connector\u003c\/td\u003e\n      \u003ctd\u003eInterbus network incoming signal line\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInterbus OUT\u003c\/td\u003e\n      \u003ctd\u003e9-pin M23 female connector\u003c\/td\u003e\n      \u003ctd\u003eInterbus network loop continuation line\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDigital Inputs 1 - 8\u003c\/td\u003e\n      \u003ctd\u003e8 x 3-pin M8 female sockets\u003c\/td\u003e\n      \u003ctd\u003eStandard digital sensor input channels\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Supply Feed\u003c\/td\u003e\n      \u003ctd\u003e4-pin M8 male connector\u003c\/td\u003e\n      \u003ctd\u003e24 V DC control and sensor power feed input\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Downstream\u003c\/td\u003e\n      \u003ctd\u003e4-pin M8 female connector\u003c\/td\u003e\n      \u003ctd\u003ePower distribution loop to subsequent modules\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eEnsure the entire automation system power supply is de-energized before mounting or wiring the device.\u003c\/li\u003e\n  \u003cli\u003eMount the module directly onto a flat machine surface or mounting profile using the designated integrated mounting holes. Secure the unit to prevent mechanical play.\u003c\/li\u003e\n  \u003cli\u003eConnect the incoming Interbus cable to the 9-pin M23 male socket, and loop to downstream units using the female M23 socket if required.\u003c\/li\u003e\n  \u003cli\u003eEnsure all M8 sensor cables are correctly aligned and tightened to preserve the IP67 environmental sealing.\u003c\/li\u003e\n  \u003cli\u003eVerify the power supply feeds meet the 24 V DC specification, and wire them using correct polarity via the standard 4-pin M8 connection.\u003c\/li\u003e\n  \u003cli\u003ePerform electrical and functional grounding checks to prevent EMI issues.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106466357611,"sku":"IP1001-B400","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ip1001-b400-ai0agmz2k2r.png?v=1776244863","url":"https:\/\/www.plcprotech.com\/it\/products\/beckhoff-ip1001-b400-interbus-fieldbus-box","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}