{"product_id":"beckhoff-ip1002-b310-fieldbus-box","title":"BECKHOFF IP1002-B310 Fieldbus Box","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBECKHOFF IP1002-B310\u003c\/strong\u003e is a decentralized Fieldbus Box featuring an integrated PROFIBUS interface and 8 digital inputs. Designed for machine-level installation without a control cabinet, this IP65\/66\/67-rated module connects binary control signals directly to a PROFIBUS DP network in harsh industrial environments.\u003c\/p\u003e\n\u003cp\u003eEquipped with M12 connectors for signal acquisition and M8 connectors for power distribution, the IP1002-B310 integrates into automated systems requiring distributed signal collection. Configuration is supported via the KS2000 software or the controller utilizing DP-V1 extensions, with automatic baud rate detection up to 12 Mbaud.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e8-channel digital input configuration conforming to EN 61131-2, type 2\u003c\/li\u003e\n  \u003cli\u003eIntegrated PROFIBUS DP interface with automatic baud rate detection up to 12 Mbaud\u003c\/li\u003e\n  \u003cli\u003eM12 connection technology for secure sensor wiring\u003c\/li\u003e\n  \u003cli\u003eM8 connectors for 24 V DC power feed and downstream connection\u003c\/li\u003e\n  \u003cli\u003eRugged PA6 polyamide housing with IP65\/66\/67 protection rating for cabinet-free installation\u003c\/li\u003e\n  \u003cli\u003eDP-V1 extension support for flexible parameterization and diagnostics\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDecentralized machine building and factory automation\u003c\/li\u003e\n  \u003cli\u003eConveyor and material handling systems\u003c\/li\u003e\n  \u003cli\u003eAssembly lines and packaging machinery\u003c\/li\u003e\n  \u003cli\u003eIndustrial environments requiring cabinet-free I\/O distribution\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBECKHOFF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eExact Model\u003c\/td\u003e\n      \u003ctd\u003eIP1002-B310\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003eFieldbus Box\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eHousing Type\u003c\/td\u003e\n      \u003ctd\u003eStandard housing\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaterial\u003c\/td\u003e\n      \u003ctd\u003ePA6 (polyamide)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n      \u003ctd\u003e30 mm x 175 mm x 26.5 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInstallation Position\u003c\/td\u003e\n      \u003ctd\u003eVariable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMounting\u003c\/td\u003e\n      \u003ctd\u003e2 fixing holes 3.5 mm diameter for M3\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eDigital Inputs\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNumber of Inputs\u003c\/td\u003e\n      \u003ctd\u003e8\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInput Connections\u003c\/td\u003e\n      \u003ctd\u003eM12, screw type\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n      \u003ctd\u003e24 V DC (-15 %\/+20 %)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInput Filter\u003c\/td\u003e\n      \u003ctd\u003e3.0 ms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\"0\" Signal Voltage\u003c\/td\u003e\n      \u003ctd\u003e-3 to +5 V (EN 61131-2, type 2)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\"1\" Signal Voltage\u003c\/td\u003e\n      \u003ctd\u003e11 to 30 V (EN 61131-2, type 2)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInput Current\u003c\/td\u003e\n      \u003ctd\u003etyp. 6 mA (EN 61131-2, type 2)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSensor Supply\u003c\/td\u003e\n      \u003ctd\u003efrom control voltage, max. 0.5 A, short-circuit proof in total\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBit Width in Process Image\u003c\/td\u003e\n      \u003ctd\u003e8 inputs\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eCommunication and PROFIBUS Interface\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBus System\u003c\/td\u003e\n      \u003ctd\u003ePROFIBUS DP\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBus Interface\u003c\/td\u003e\n      \u003ctd\u003e1 x M12 socket, 5-pin, B-coded\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eData Transfer Rates\u003c\/td\u003e\n      \u003ctd\u003eAutomatic detection up to 12 Mbaud\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConfiguration\u003c\/td\u003e\n      \u003ctd\u003eVia KS2000 or controller, DP-V1 extensions supported\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eElectrical\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eControl Voltage Supply\u003c\/td\u003e\n      \u003ctd\u003e24 V DC (-15 %\/+20 %)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Supply Connection\u003c\/td\u003e\n      \u003ctd\u003eFeed: 1 x M8 male socket, 4-pin; Downstream: 1 x M8 female socket, 4-pin\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBox Supply Current\u003c\/td\u003e\n      \u003ctd\u003e85 mA + current consumption of sensors, max. 0.5 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eElectrical Isolation\u003c\/td\u003e\n      \u003ctd\u003eControl voltage\/fieldbus: no; control voltage\/inputs: according to I\/O type\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eEnvironmental and Approvals\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n      \u003ctd\u003e0 to +55 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStorage Temperature Range\u003c\/td\u003e\n      \u003ctd\u003e-25 to +85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eVibration \/ Shock Resistance\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 60068-2-6 \/ EN 60068-2-27\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEMC Immunity \/ Emission\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 61000-6-2 \/ EN 61000-6-4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProtection Class\u003c\/td\u003e\n      \u003ctd\u003eIP65 \/ IP66 \/ IP67 (conforms to EN 60529)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eApprovals \/ Markings\u003c\/td\u003e\n      \u003ctd\u003eCE, UL\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eInterface \/ Terminal\u003c\/th\u003e\n      \u003cth\u003eFunction\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eM12 Socket (5-pin, B-coded)\u003c\/td\u003e\n      \u003ctd\u003ePROFIBUS DP bus interface\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eM12 Sockets (Screw type)\u003c\/td\u003e\n      \u003ctd\u003e8 x Digital inputs (channels 1 to 8)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eM8 Male Socket (4-pin)\u003c\/td\u003e\n      \u003ctd\u003eControl voltage power feed (24 V DC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eM8 Female Socket (4-pin)\u003c\/td\u003e\n      \u003ctd\u003eDownstream control voltage power connection\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eEnsure the system is completely de-energized before mounting or wiring the BECKHOFF IP1002-B310.\u003c\/li\u003e\n  \u003cli\u003eSecure the unit directly onto a flat mounting surface using two M3 screws through the 3.5 mm fixing holes.\u003c\/li\u003e\n  \u003cli\u003eConnect the 24 V DC control voltage supply to the M8 male feed socket using a compatible 4-pin cable.\u003c\/li\u003e\n  \u003cli\u003eConnect PROFIBUS communication cables to the B-coded M12 bus socket.\u003c\/li\u003e\n  \u003cli\u003eAttach binary sensors to the M12 input channels, ensuring signal levels conform to EN 61131-2, type 2 requirements.\u003c\/li\u003e\n  \u003cli\u003eVerify all M12 and M8 screw connections are securely fastened to maintain IP65\/66\/67 environmental protection.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106470584683,"sku":"IP1002-B310","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ip1002-b310-4dtcwfxwibh.png?v=1776244870","url":"https:\/\/www.plcprotech.com\/it\/products\/beckhoff-ip1002-b310-fieldbus-box","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}