{"product_id":"beckhoff-ip2302-b730-fieldbus-box","title":"BECKHOFF IP2302-B730 Fieldbus Box","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBECKHOFF IP2302-B730\u003c\/strong\u003e is a compact Fieldbus Box designed for decentralized industrial automation applications. As part of the robust IP2302 series, this device integrates digital input and digital output channels within a durable machine-mount housing, allowing direct installation in harsh industrial environments without requiring a control cabinet. It establishes communication via a Modbus fieldbus interface and operates on a standard 24 V DC industrial supply.\u003c\/p\u003e\n\u003cp\u003eEngineered for modular machine and plant construction, the unit connects local sensors and actuators directly to the controller network. The decentralized IP67 construction protects internal circuitry against dust, moisture, and mechanical stress, supporting reliable signal acquisition and actuation directly at the process level.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDecentralized Fieldbus Box design with IP67 protection for cabinet-free machine mounting\u003c\/li\u003e\n  \u003cli\u003eIntegrated digital input and digital output channel configuration\u003c\/li\u003e\n  \u003cli\u003eModbus communication interface for network integration\u003c\/li\u003e\n  \u003cli\u003eStandard 24 V DC industrial operating voltage supply\u003c\/li\u003e\n  \u003cli\u003eM12 connection technology for secure sensor and actuator cabling\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDecentralized signal collection and actuator control in modular machine building\u003c\/li\u003e\n  \u003cli\u003eConveyor and material handling systems exposed to workshop environments\u003c\/li\u003e\n  \u003cli\u003eAutomated assembly and handling machinery requiring distributed I\/O nodes\u003c\/li\u003e\n  \u003cli\u003eIndustrial plant engineering where cabinet space is limited\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBECKHOFF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eExact Model\u003c\/td\u003e\n      \u003ctd\u003eIP2302-B730\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003eFieldbus Box\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eElectrical\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNominal Voltage\u003c\/td\u003e\n      \u003ctd\u003e24 V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOutput Current per Channel\u003c\/td\u003e\n      \u003ctd\u003e0.5 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eSignal and I\/O\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDigital Inputs\u003c\/td\u003e\n      \u003ctd\u003e4 channels\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDigital Outputs\u003c\/td\u003e\n      \u003ctd\u003e4 channels\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFilter \/ Response Time\u003c\/td\u003e\n      \u003ctd\u003e3 ms\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eCommunication\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFieldbus Protocol\u003c\/td\u003e\n      \u003ctd\u003eModbus\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eConnection\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConnection Technology\u003c\/td\u003e\n      \u003ctd\u003eM12\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eVerify that the exact model number (IP2302-B730) matches your system design requirements and network specifications.\u003c\/li\u003e\n  \u003cli\u003eEnsure all power supplies and fieldbus lines are completely de-energized before beginning mechanical mounting or electrical wiring.\u003c\/li\u003e\n  \u003cli\u003eMount the Fieldbus Box securely onto a flat, stable machine surface using appropriate mounting hardware, maintaining proper clearance for M12 cable connectors.\u003c\/li\u003e\n  \u003cli\u003eInspect all M12 sensor, actuator, power, and fieldbus cables for damage before connecting them to the corresponding ports.\u003c\/li\u003e\n  \u003cli\u003eVerify the 24 V DC supply polarity and voltage levels before restoring power to the system.\u003c\/li\u003e\n  \u003cli\u003ePower on the unit and check the diagnostic LED indicators to confirm proper operational status and network communication.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106451874155,"sku":"IP2302-B730","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ip2302-b730-3mxqspqiekh.png?v=1776245005","url":"https:\/\/www.plcprotech.com\/it\/products\/beckhoff-ip2302-b730-fieldbus-box","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}