{"product_id":"beckhoff-ip2332-b518-fieldbus-box","title":"BECKHOFF IP2332-B518 Fieldbus Box","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBECKHOFF IP2332-B518\u003c\/strong\u003e is a compact decentralized Fieldbus Box designed for industrial automation environments requiring distributed signal acquisition and control. Engineered for direct machine-level mounting without the need for control cabinets, this IP65, IP66, and IP67 protected module integrates into CANopen network architectures. It facilitates reliable data communication, process data exchange, and sensor or actuator connection across harsh industrial machinery and plant floors.\u003c\/p\u003e\n\u003cp\u003eEquipped with an integrated CANopen interface, the unit supports extensive process data object (PDO) configurations and diagnostic functions. Power distribution, fieldbus connections, and peripheral signal integration are handled via robust industrial circular connectors, supporting decentralized system topologies where space efficiency and environmental resistance are critical.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eIntegrated CANopen bus interface with automatic baud rate detection from 10 kbaud up to 1 Mbaud\u003c\/li\u003e\n  \u003cli\u003eSupports up to 16 send and 16 receive process data objects (PDOs)\u003c\/li\u003e\n  \u003cli\u003eComprehensive CANopen features including life guarding, node guarding, emergency objects, variable mapping, and store\/restore functionality\u003c\/li\u003e\n  \u003cli\u003eRobust IP65, IP66, and IP67 protection rating for harsh industrial environments without control cabinets\u003c\/li\u003e\n  \u003cli\u003eFlexible configuration options via the KS2000 configuration software or through service data objects (SDOs) from the controller\u003c\/li\u003e\n  \u003cli\u003eIntegrated M12 tee-connector for streamlined bus wiring topology\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDecentralized machine control and automation systems\u003c\/li\u003e\n  \u003cli\u003eAutomotive assembly lines and material handling equipment\u003c\/li\u003e\n  \u003cli\u003ePackaging and sorting machinery requiring cabinet-free I\/O distribution\u003c\/li\u003e\n  \u003cli\u003eConveyor systems and distributed manufacturing cells\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBECKHOFF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eExact Model\u003c\/td\u003e\n      \u003ctd\u003eIP2332-B518\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003eFieldbus Box\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eExtension modules\u003c\/td\u003e\n      \u003ctd\u003e-\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eCommunication and Bus Interface\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBus Interface\u003c\/td\u003e\n      \u003ctd\u003e1 x M12 plug, 5-pin; 1 x M12 socket, 5-pin (tee-connector integrated)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eData Transfer Rates\u003c\/td\u003e\n      \u003ctd\u003eAutomatic detection of 10 kbaud up to 1 Mbaud\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eData Transfer Medium\u003c\/td\u003e\n      \u003ctd\u003eShielded copper cable, 2 x signal, 1 x CAN ground (recommended)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNumber of PDOs (CANopen)\u003c\/td\u003e\n      \u003ctd\u003e16 send and 16 receive process data objects\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eAdditional CANopen Features\u003c\/td\u003e\n      \u003ctd\u003eLife, node guarding, emergency object, variable mapping, store\/restore\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eI\/O Communication Types\u003c\/td\u003e\n      \u003ctd\u003eEvent driven, cyclic, synchron, polling\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConfiguration Possibility\u003c\/td\u003e\n      \u003ctd\u003eThrough KS2000 or the controller (service data objects)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eElectrical\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Supply Control Voltage\u003c\/td\u003e\n      \u003ctd\u003e24 V DC (-15 %\/+20 %)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Supply Load Voltage\u003c\/td\u003e\n      \u003ctd\u003eAccording to I\/O type\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Supply Connection\u003c\/td\u003e\n      \u003ctd\u003eFeed: 1 x M8 male socket, 4-pin; Downstream connection: 1 x M8 female socket, 4-pin\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBox Supply Current\u003c\/td\u003e\n      \u003ctd\u003e45 mA + current consumption of sensors, max. 0.5 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eAuxiliary Power Current\u003c\/td\u003e\n      \u003ctd\u003eAccording to I\/O type\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eElectrical Isolation\u003c\/td\u003e\n      \u003ctd\u003eControl voltage\/fieldbus: 500 V; Control voltage\/inputs or outputs: according to I\/O type\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eEnvironmental and Mechanical\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n      \u003ctd\u003e0 to +55 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStorage Temperature Range\u003c\/td\u003e\n      \u003ctd\u003e-25 to +85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eVibration Resistance\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 60068-2-6\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eShock Resistance\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 60068-2-27\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEMC Immunity\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 61000-6-2\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEMC Emission\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 61000-6-4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProtection Rating\u003c\/td\u003e\n      \u003ctd\u003eIP65, IP66, IP67 (conforms to EN 60529)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInstallation Position\u003c\/td\u003e\n      \u003ctd\u003eVariable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eApprovals and Markings\u003c\/td\u003e\n      \u003ctd\u003eCE, UL\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eInterface\u003c\/th\u003e\n      \u003cth\u003eFunction\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eM12 Plug (5-pin) \/ M12 Socket (5-pin)\u003c\/td\u003e\n      \u003ctd\u003eCANopen bus interface (integrated tee-connector)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eM8 Male Socket (4-pin)\u003c\/td\u003e\n      \u003ctd\u003eControl voltage power supply feed\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eM8 Female Socket (4-pin)\u003c\/td\u003e\n      \u003ctd\u003eDownstream control voltage power supply connection\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eEnsure the system is completely de-energized before mounting or servicing the BECKHOFF IP2332-B518 Fieldbus Box.\u003c\/li\u003e\n  \u003cli\u003eInspect the module and connectors for any physical damage or contamination.\u003c\/li\u003e\n  \u003cli\u003eMount the unit securely to a flat, stable machine surface in any variable orientation permitted by the application.\u003c\/li\u003e\n  \u003cli\u003eConnect the 24 V DC control voltage supply to the M8 feed socket using appropriate shielded cabling.\u003c\/li\u003e\n  \u003cli\u003eConnect the CANopen network cables to the M12 bus ports, ensuring proper shielding and termination according to CANopen specifications.\u003c\/li\u003e\n  \u003cli\u003eVerify all cable connections, potential levels, and address\/baud rate settings before restoring power.\u003c\/li\u003e\n  \u003cli\u003ePower on the system and verify operational status via diagnostic LEDs and controller communication.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106462196075,"sku":"IP2332-B518","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ip2332-b518-h2xjl1onoff.png?v=1776245067","url":"https:\/\/www.plcprotech.com\/it\/products\/beckhoff-ip2332-b518-fieldbus-box","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}