{"product_id":"bently-nevada-135489-03-3500-42m-i-o-module-with-internal-barriers","title":"Bently Nevada 135489-03 3500\/42M I\/O Module with Internal Barriers","description":"\u003ch3\u003eDescrizione\u003c\/h3\u003e\n\u003cp\u003eIl modulo \u003cstrong\u003e135489-03\u003c\/strong\u003e è un \u003cstrong\u003emodulo I\/O con barriere interne\u003c\/strong\u003e per slot posteriore, progettato per il sistema \u003cstrong\u003eBently Nevada 3500\/42M Proximitor Seismic Monitor\u003c\/strong\u003e. Fornisce quattro canali di barriere interne a sicurezza intrinseca e interfacce di cablaggio con terminazioni interne, configurate specificamente per il collegamento ai \u003cstrong\u003esensori Velomitor\u003c\/strong\u003e sui canali da 1 a 4.\u003c\/p\u003e\n\u003cp\u003eQuesto modulo instrada i segnali dinamici dei trasduttori al \u003cstrong\u003e3500\/42M\u003c\/strong\u003e monitor principale di elaborazione, offrendo al contempo circuiti integrati di isolamento galvanico e a Zener necessari per le installazioni in aree pericolose. Gli operatori e gli ingegneri dell'impianto utilizzano il \u003cstrong\u003e135489-03\u003c\/strong\u003e per monitorare i parametri di vibrazione rotazionale e velocità dei macchinari industriali, trasmettendo valori statici critici e segnali bufferizzati ai sistemi di controllo, alle reti dell'impianto e alle uscite del registratore dei singoli canali.\u003c\/p\u003e\n\u003ch3\u003eCaratteristiche\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIntegra quattro canali di barriere interne a sicurezza intrinseca per il collegamento diretto ai sensori Velomitor.\u003c\/li\u003e\n\u003cli\u003eFornisce connettori a morsettiera interna per la terminazione del cablaggio di campo.\u003c\/li\u003e\n\u003cli\u003eSi installa in un singolo slot posteriore a tutta altezza del rack, direttamente dietro la scheda del monitor principale 3500\/42M.\u003c\/li\u003e\n\u003cli\u003eInclude connessioni indipendenti per l'uscita del registratore analogico per tutti e quattro i segnali dei canali.\u003c\/li\u003e\n\u003cli\u003eCertificato per installazioni in luoghi pericolosi secondo i requisiti cNRTLus, ATEX e IECEx.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplicazioni\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMonitoraggio continuo di vibrazioni e velocità per pompe industriali, ventilatori e motori elettrici\u003c\/li\u003e\n\u003cli\u003eMonitoraggio delle condizioni di compressori e turbine a vapore in aree di processo pericolose\u003c\/li\u003e\n\u003cli\u003eCondizionamento del segnale del trasduttore di campo a sicurezza intrinseca per la protezione dei macchinari rotanti\u003c\/li\u003e\n\u003cli\u003eProtezione online 24 ore su 24, 7 giorni su 7, dei macchinari in impianti petroliferi e del gas, chimici e di generazione elettrica\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInformazioni per l'ordine\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOpzione d'ordine\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eNumero di parte\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescrizione\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eCompatibilità dei trasduttori\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAA: 06\u003c\/td\u003e\n\u003ctd\u003e135489-03\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eModulo I\/O con barriere interne, \u003c\/p\u003e\n\u003cp\u003eterminazioni interne, 4 x Velomitor\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003eVelomitor sui canali da 1 a 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSpecifiche tecniche\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParametro\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecifiche\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduttore\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumero di parte\u003c\/td\u003e\n\u003ctd\u003e135489-03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTipo di modulo\u003c\/td\u003e\n\u003ctd\u003eModulo I\/O con barriere (terminazioni interne)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfigurazione dei canali\u003c\/td\u003e\n\u003ctd\u003e4 x Velomitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperatura operativa\u003c\/td\u003e\n\u003ctd\u003e0 °C a +65 °C (32 °F a +150 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperatura di stoccaggio\u003c\/td\u003e\n\u003ctd\u003e-40 °C a +85 °C (-40 °F a +185 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUmidità\u003c\/td\u003e\n\u003ctd\u003e95%, senza condensa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRequisiti di spazio nel rack\u003c\/td\u003e\n\u003ctd\u003e1 slot posteriore a tutta altezza\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensioni (A x L x P)\u003c\/td\u003e\n\u003ctd\u003e241,3 mm x 24,4 mm x 163,1 mm (9,50 in x 0,96 in x 6,42 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeso\u003c\/td\u003e\n\u003ctd\u003e0,46 kg (1,01 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVmax della barriera sismica\u003c\/td\u003e\n\u003ctd\u003e27,25 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImax della barriera sismica\u003c\/td\u003e\n\u003ctd\u003e91,8 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRmin della barriera sismica (PWR)\u003c\/td\u003e\n\u003ctd\u003e297 ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnessioni e interfacce\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eMorsetto \/ Designazione\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunzione\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePWR\/B\u003c\/td\u003e\n\u003ctd\u003eAlimentazione del trasduttore\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOM\u003c\/td\u003e\n\u003ctd\u003eComune del trasduttore\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSIG\/A\u003c\/td\u003e\n\u003ctd\u003eIngresso del segnale del trasduttore\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSHLD\u003c\/td\u003e\n\u003ctd\u003eConnessione della schermatura del cavo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eINHB\u003c\/td\u003e\n\u003ctd\u003eIngresso di inibizione\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRET\u003c\/td\u003e\n\u003ctd\u003eRitorno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eREC1 - REC4\u003c\/td\u003e\n\u003ctd\u003eUscite del registratore dei canali da 1 a 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eLinee guida per l'installazione\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInserire il modulo in uno slot posteriore a tutta altezza del rack, situato direttamente dietro il modulo monitor principale di elaborazione 3500\/42M associato.\u003c\/li\u003e\n\u003cli\u003eCollegare i cavi dei sensori di campo direttamente ai blocchi di morsettiere a vite del canale dedicato.\u003c\/li\u003e\n\u003cli\u003eMantenere una corretta messa a terra e terminazione della schermatura secondo il disegno di installazione 138547 per la conformità alla sicurezza intrinseca nelle aree pericolose.\u003c\/li\u003e\n\u003cli\u003eAssicurarsi che le condizioni operative ambientali rimangano nell'intervallo specificato da 0 °C a +65 °C.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConformità e certificazioni\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ecNRTLus: Classe I, Zona 2: AEx\/Ex nA nC ic [ia Ga] IIC T4 Gc; Classe I, Zona 2: AEx\/Ex ec nC ic [ia Ga] IIC T4 Gc; Classe I, Divisione 2, Gruppi A, B, C e D (W\/ uscita IS per la Divisione 1); T4 a Ta = -20 °C a +65 °C (-4 °F a +149 °F) se installato secondo il disegno 138547\u003c\/li\u003e\n\u003cli\u003eATEX\/IECEx: Ex nA nC ic [ia Ga] IIC T4 Gc; Ex ec nC ic [ia Ga] IIC T4 Gc; T4 a Ta = -20 °C a +65 °C (-4 °F a +149 °F) se installato secondo il disegno 138547\u003c\/li\u003e\n\u003cli\u003eEMC: Direttiva della Comunità Europea 2014\/30\/UE (EN 61000-6-2, EN 61000-6-4)\u003c\/li\u003e\n\u003cli\u003eSicurezza elettrica: Direttiva della Comunità Europea 2014\/35\/UE (EN 61010-1)\u003c\/li\u003e\n\u003cli\u003eRoHS: Direttiva della Comunità Europea 2011\/65\/UE; RoHS Cina SJ\/T 11364-2024\u003c\/li\u003e\n\u003cli\u003eMarittimo: applicazioni marine e offshore ABS; norme DNV GL per la classificazione\u003c\/li\u003e\n\u003cli\u003eFCC: Conforme alla Parte 15 delle norme FCC\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666868302187,"sku":"135489-03","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-135489-03-70-i-o-module-xa2ks3av1et_6966ec4c-7c1a-429f-812c-260883c5e2be.jpg?v=1765449537","url":"https:\/\/www.plcprotech.com\/it\/products\/bently-nevada-135489-03-3500-42m-i-o-module-with-internal-barriers","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}