{"product_id":"bently-nevada-135813-01-3500-93-display-interface-i-o-module","title":"Bently Nevada 135813-01 3500\/93 Display Interface I\/O Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada \u003cstrong\u003e135813-01\u003c\/strong\u003e is a Display Interface I\/O Module designed for local or remote visual indication of all 3500 Machinery Protection System information residing in the rack. The \u003cstrong\u003e135813-01\u003c\/strong\u003e interacts with the 3500 backplane network to collect current values, System Event Lists, Alarm Event Lists, and status data across all channel, monitor, relay, Keyphasor, or tachometer modules. The module provides hardware interface output connectivity for communication with the 3500\/93 Display Unit via an RS422 physical layer supporting Bently Nevada proprietary protocol and Modbus protocol.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOccupies 1 full-height rear slot in the 3500 rack\u003c\/li\u003e\n\u003cli\u003eFeatures a dedicated Display Communications Port for RS422 connection to the 3500\/93 Display Unit\u003c\/li\u003e\n\u003cli\u003eCollects machinery protection data and event status via a high-speed internal backplane network\u003c\/li\u003e\n\u003cli\u003eEnables rear cable routing option for connecting the display unit to the 3500 Machinery Protection System\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLocal or remote display interface connection for 3500 Machinery Protection Systems\u003c\/li\u003e\n\u003cli\u003eIndustrial rotating machinery monitoring and visual indication\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003ePart Number\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e135813-01\u003c\/td\u003e\n\u003ctd\u003e3500\/93 Display Interface I\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e135799-01\u003c\/td\u003e\n\u003ctd\u003e3500\/93 Display Interface Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e135799-02\u003c\/td\u003e\n\u003ctd\u003e3500\/93 Display Interface Module (use with A05 thru A08 options)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e135785-01\u003c\/td\u003e\n\u003ctd\u003e3500\/93 Display Unit, non back-lighted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e135785-02\u003c\/td\u003e\n\u003ctd\u003e3500\/93 Display Unit, back-lighted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e135813-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDisplay Interface I\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241.3 mm x 24.4 mm x 99.1 mm (9.50 in x 0.96 in x 3.90 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.38 kg (0.84 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRack Space Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 full-height rear slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 degC to +65 degC (-22 degF to +150 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC (-40 degF to +185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95%, noncondensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Hardware\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS422 Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGE Bently Nevada proprietary protocol, Modbus protocol (based on AEG PI-MBUS-300 Rev. E Reference Manual)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannel Update Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 second, typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eConnector \/ Port\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Communications Port\u003c\/td\u003e\n\u003ctd\u003eRS422 interface for connecting to the 3500\/93 Display Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstalls in 1 full-height rear slot of the 3500 Machinery Protection System rack.\u003c\/li\u003e\n\u003cli\u003eServes as the rear wiring interface point connecting to the front-mounted Display Interface Module (DIM) via the rack backplane.\u003c\/li\u003e\n\u003cli\u003eAllows display connection routing from the rear of the rack when the display is not face-mounted.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard \/ Directive\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC Standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN 61000-6-2 Immunity for Industrial Environments, EN 55011\/CISPR 11 ISM Equipment, EN 61000-6-4 Emissions for Industrial Environments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEuropean Community Directives\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEMC Directive 2004\/108\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical Safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN 61010-1, 2006\/95\/EC Low Voltage Directive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCSA\/NRTL\/C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOption (01): AEx nA IIC: Class I, Zone 2, Div 2 Groups A, B, C, D; T4 @ Ta = -30 degC to +65 degC (-22 degF to +150 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eATEX\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOption (02): II 3\/ (1) G Ex nC[nL Gc] IIC T4 Gc; T4 @ Ta = -20 degC to +65 degC (-4 degF to +150 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrazil\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOption (02): BR-Ex nC [nL] IIC T4; T4 @ Ta = -20 degC to +65 degC (-4 degF to +150 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSouth Africa\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOption (02): Ex nCAL [ia] IIC T4, Ex nCAL [L] IIC T4; T4 @ Ta = -20 degC to +65 degC (-4 degF to +150 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666851295595,"sku":"135813-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-135813-01-display-interface-i-o-module-q2bfa01gfs1_bc5bfd62-9a70-40b6-bcae-429336ab90ea.jpg?v=1765449050","url":"https:\/\/www.plcprotech.com\/it\/products\/bently-nevada-135813-01-3500-93-display-interface-i-o-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}