{"product_id":"bently-nevada-146031-02-3500-22m-100base-fx-fiber-optic-i-o-module","title":"Bently Nevada 146031-02 3500\/22M 100Base-FX (Fiber Optic) I\/O Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 146031-02\u003c\/strong\u003e is a 100Base-FX Fiber Optic Ethernet I\/O Module designed for use with the \u003cstrong\u003e3500\/22M Transient Data Interface Module\u003c\/strong\u003e within the Bently Nevada 3500 Machinery Protection System. Installed in the rear slot of a 3500 rack, the \u003cstrong\u003e146031-02\u003c\/strong\u003e provides full-duplex multimode fiber optic Ethernet communication to interface the rack with System 1 Condition Monitoring and Diagnostic software, 3500 System Configuration software, and 3500 Display software. It includes system contacts for Trip Multiply, Alarm Inhibit, and Rack Reset, an OK Relay contact for rack status annunciation, and a 2-pin terminal for connecting Signal Common to a single-point instrument ground.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProvides 100Base-FX fiber optic Ethernet interface for the 3500\/22M TDI.\u003c\/li\u003e\n\u003cli\u003eUtilizes MT-RJ male connector for multimode fiber optic cabling up to 2000 meters (6560 feet).\u003c\/li\u003e\n\u003cli\u003eSupports BN Host Protocol and BN TDI Protocol over Ethernet TCP\/IP.\u003c\/li\u003e\n\u003cli\u003eIncludes OK Relay output for indicating normal rack operation or fault conditions.\u003c\/li\u003e\n\u003cli\u003eFeatures dry contact system inputs for Trip Multiply, Alarm Inhibit, and Rack Reset.\u003c\/li\u003e\n\u003cli\u003eIncludes a 2-pin Signal Common connector for instrument ground connection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-noise industrial environments requiring electromagnetic immunity via fiber optic communication.\u003c\/li\u003e\n\u003cli\u003eLong-distance machinery protection network links up to 2000 meters between 3500 racks and control rooms.\u003c\/li\u003e\n\u003cli\u003eIntegration with System 1 Condition Monitoring and Diagnostic software and 3500 Configuration software.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e3500\/22-AA-BB-CC\u003c\/td\u003e\n\u003ctd\u003e3500\/22M TDI Module and I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOption B (I\/O Module Type) - 02\u003c\/td\u003e\n\u003ctd\u003e100Base-FX (Fiber Optic) Ethernet I\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOption B (I\/O Module Type) - 04\u003c\/td\u003e\n\u003ctd\u003e100Base-FX (Fiber Optic) Ethernet I\/O Module with gold-plated OK Relay contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpares: 146031-02\u003c\/td\u003e\n\u003ctd\u003e100Base-FX (Fiber Optic) I\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpares: 146031-04\u003c\/td\u003e\n\u003ctd\u003e100Base-FX (Fiber Optic) I\/O Module GLD Plated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e146031-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003e100Base-FX (Fiber Optic) Ethernet I\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eBently Nevada 3500\/22M TDI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eEthernet, 100Base-FX, Fiber Optic, full duplex multimode (IEEE802.3u compliant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtocols Supported\u003c\/td\u003e\n\u003ctd\u003eBN Host Protocol and BN TDI Protocol using Ethernet TCP\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Connection\u003c\/td\u003e\n\u003ctd\u003eMT-RJ Male Fiber Optic connector (requires MT-RJ Female on cabling)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Cable Length\u003c\/td\u003e\n\u003ctd\u003e2000 metres (6560 feet), multimode fiber optic cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard OK Relay Rating\u003c\/td\u003e\n\u003ctd\u003e5 A @ 24 Vdc \/ 120 Vac, 120 Watts \/ 600 VA Switched Power (maximum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Contacts\u003c\/td\u003e\n\u003ctd\u003eTrip Multiply, Alarm Inhibit, Rack Reset (\u0026lt;1 mAdc, Dry Contact to Common)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-30 degC to +65 degC (-22 degF to +149 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC (-40 degF to +185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e241.3 mm x 24.4 mm x 99.1 mm (9.50 in x 0.96 in x 3.90 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.20 kg (0.44 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Space Requirements\u003c\/td\u003e\n\u003ctd\u003e1 full-height rear slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Pin\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMT-RJ Male Connector\u003c\/td\u003e\n\u003ctd\u003e100Base-FX Fiber Optic Ethernet connection for configuration and data collection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOK Relay Terminal\u003c\/td\u003e\n\u003ctd\u003eRelay contact for rack OK status annunciation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Common Terminal\u003c\/td\u003e\n\u003ctd\u003e2-pin connector for connecting Signal Common to single point Instrument Ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Contacts\u003c\/td\u003e\n\u003ctd\u003eContacts for Trip Multiply, Alarm Inhibit, and Rack Reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlot Placement:\u003c\/strong\u003e Install the 146031-02 I\/O module into the full-height rear slot directly behind the 3500\/22M TDI main module in Slot 1 of the 3500 rack.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFiber Optic Cabling:\u003c\/strong\u003e The module features an MT-RJ Male connector. Fiber optic cables must use an MT-RJ Female connector to ensure proper mating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Grounding:\u003c\/strong\u003e When connecting Signal Common to a single-point instrument ground via the 2-pin connector, slide the selector switch on the side of the Power Input Module (PIM) in the direction of the \"HP\" arrow to isolate Signal Common from chassis ground.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUpgrade Sequence Caution:\u003c\/strong\u003e When upgrading a rack from a 3500\/20 RIM to a 3500\/22 TDI, always remove the RIM main module and RIM I\/O module before inserting the new TDI I\/O module and TDI main module to prevent hardware damage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC:\u003c\/strong\u003e European Community Directive 2014\/30\/EU; EN 61000-6-2, EN 61000-6-4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Safety:\u003c\/strong\u003e European Community Directive 2014\/35\/EU; EN 61010-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e European Community Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFCC:\u003c\/strong\u003e Complies with part 15 of the FCC Rules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaritime:\u003c\/strong\u003e DNV GL rules for classification; ABS Rules for Condition of Classification, Part 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area Approvals:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003ecNRTLus: Class I, Zone 2: AEx\/Ex nA nC ic IIC T4 Gc; Class I, Zone 2: AEx\/Ex ec nC ic IIC T4 Gc; Class I, Division 2, Groups A, B, C, and D; T4 @ Ta = -20 degC to +65 degC (-4 degF to +149 degF)\u003c\/li\u003e\n\u003cli\u003eATEX\/IECEx: Ex II 3 G, Ex nA nC ic IIC T4 Gc, Ex ec nC ic IIC T4 Gc, T4 @ Ta = -20 degC to +65 degC (-4 degF to +149 degF)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666867548523,"sku":"146031-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-146031-02-transient-data-interface-module-vxatwz05g2c_9c8ca786-0bbb-4941-8e3a-06aecca2c14c.jpg?v=1765449506","url":"https:\/\/www.plcprotech.com\/it\/products\/bently-nevada-146031-02-3500-22m-100base-fx-fiber-optic-i-o-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}