{"product_id":"bently-nevada-163179-02-3500-61-temperature-monitor","title":"Bently Nevada 163179-02 3500\/61 Monitor di temperatura","description":"\u003ch3\u003ePanoramica del prodotto\u003c\/h3\u003e\n\u003cp\u003eIl\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e163179-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eè uno strumento professionale di monitoraggio della temperatura a 6 canali, progettato per il sistema di protezione delle macchine\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 3500 Series\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esecondo gli standard industriali. Operando come modulo centrale di valutazione termica, questa scheda elabora continuamente gli ingressi dei sensori di temperatura a resistenza (RTD) e delle termocoppie per proteggere i componenti critici delle macchine dal sovraccarico termico. Gli ambienti applicativi dell’industria pesante, tra cui centrali termoelettriche a carico di base, complessi di liquefazione del GNL e raffinerie petrolchimiche ad alta capacità, si affidano al\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e163179-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eper monitorare le temperature critiche dei cuscinetti, gli avvolgimenti dello statore e i collettori del fluido lubrificante. Fornendo funzionalità operative identiche a quelle dell’infrastruttura 3500\/61 di base, insieme a sei canali integrati per registratori analogici, il modulo garantisce la registrazione indipendente della telemetria. Questa sorveglianza costante consente al sistema di sicurezza di avviare rapidamente comandi automatici di arresto prima che perdite critiche di attrito o raffreddamento provochino danni catastrofici ai componenti, riducendo drasticamente i tempi di fermo non programmati dell’impianto.\u003c\/p\u003e\n\u003ch3\u003eArchitettura hardware e instradamento della telemetria\u003c\/h3\u003e\n\u003cp\u003eL’ingegneria funzionale, l’isolamento a livello hardware e i circuiti di monitoraggio analogico del\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e163179-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoffrono un monitoraggio termico delle macchine altamente flessibile e sicuro:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAcquisizione parallela a sei canali:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eValuta simultaneamente sei ingressi analogici indipendenti della temperatura, fornendo un condizionamento del segnale dedicato e ad alta velocità su tutti i canali, senza ritardi dovuti alla scansione dei canali.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGenerazione onboard del circuito di corrente:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDispone di sei uscite di corrente integrate da +4 a +20 mA, proporzionali alla configurazione di fondo scala del monitor, consentendo un instradamento fluido della telemetria analogica verso sistemi DCS o SCADA esterni.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCircuito di protezione dai cortocircuiti:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegra un isolamento elettronico indipendente dai guasti su tutti i circuiti delle uscite dei registratori, assicurando che eventuali cortocircuiti del cablaggio esterno o disconnessioni del circuito non influiscano in alcun modo sulla logica centrale di protezione delle macchine.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompatibilità con l’architettura I\/O adattiva:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFunziona in modo affidabile con moduli di terminazione interni, moduli di terminazione esterni e blocchi hardware specializzati con barriere di sicurezza interne, per adattarsi a diversi standard di installazione nelle zone operative.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRoutine di autodiagnosi continua:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUtilizza un circuito interno di sorveglianza che monitora l’integrità strutturale del cablaggio degli ingressi e dei trasferimenti dati sul backplane, facendo lampeggiare i codici di guasto sul pannello frontale se un circuito del sensore si apre o va in cortocircuito.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eParametri tecnici e soglie operative\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecifica hardware\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eValore ingegneristico certificato\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIdentificativo del modello\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e163179-02 (3500\/61)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduttore del marchio\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada (Baker Hughes)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLinea del sistema di controllo\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSistema di protezione delle macchine 3500\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eClassificazione del modulo\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMonitor di temperatura a 6 canali con registratori\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIntervallo di uscita analogica\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6 canali con circuiti di corrente dedicati da +4 a +20 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConsumo energetico nominale\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAssorbimento medio di base: 9,0 watt\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTemperatura operativa (I\/O standard)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntervallo termico ambientale da -30 a +65 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTemperatura operativa (barriera interna)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntervallo termico ambientale da 0 a +65 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIntervallo della temperatura di stoccaggio\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLimiti strutturali da -40 a +85 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePeso netto dell’hardware\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMassa di base: 0,91 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensioni d’ingombro\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e241,3 mm H x 24,4 mm W x 241,8 mm P\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLuogo di produzione\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMinden, Nevada, USA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDomande frequenti sulla sicurezza delle macchine e sul monitoraggio termico\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eUn guasto al cablaggio del circuito esterno sulle uscite dei registratori interrompe la logica primaria di arresto della macchina?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. La piattaforma hardware 163179-02 dispone di un isolamento galvanico ed elettronico completo dai cortocircuiti su ogni singola uscita del registratore da +4 a +20 mA. Se il circuito di uno strumento di campo a valle subisce un cortocircuito o un guasto verso terra, il monitoraggio della protezione primaria e gli avvisi di comando automatico dei relè restano pienamente operativi.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQual è la causa della variazione del limite inferiore della temperatura operativa tra le diverse installazioni?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eI limiti termici variano in base al modulo di interfaccia del backplane selezionato. L’utilizzo di moduli I\/O di terminazione interni o esterni standard consente alla scheda di funzionare in un ampio intervallo da -30 a +65 °C. Tuttavia, quando viene abbinata a moduli I\/O con barriera interna per il contenimento a sicurezza intrinseca, il limite operativo inferiore passa a 0 °C, mentre quello superiore resta a +65 °C.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eI valori dei registratori sono regolabili oppure seguono una scala fissa relativa all’intervallo di ingresso?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eLe sei uscite di corrente indipendenti generano segnali analogici strettamente proporzionali all’intervallo di fondo scala configurato all’interno del modulo monitor 3500\/61. Questi valori corrispondono gradualmente alle soglie di avviso e di pericolo programmate dall’utente tramite l’utilità 3500 Rack Configuration Software.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eGuida all’ingegneria e all’installazione\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrità della schermatura e corrispondenza dei cavi dei sensori:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eInstradare tutti i cavi di campo degli RTD e delle termocoppie attraverso cavi schermati per strumentazione a doppino intrecciato di alta qualità, per prevenire l’induzione di disturbi elettromagnetici provenienti dalle linee di alimentazione dei motori ad alta tensione. Collegare la schermatura complessiva in treccia di rame esclusivamente alla barra di messa a terra dello strumento designata, all’interno dell’armadio del rack di schede 3500. Assicurarsi che i conduttori di campo abbiano lunghezza e sezione trasversale corrispondenti, soprattutto nelle configurazioni RTD a 3 fili, per eliminare gli squilibri di resistenza di linea che causano derive di misura sulla morsettiera d’ingresso 3500\/61.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNormative sulle barriere a sicurezza intrinseca e ventilazione termica:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eQuando si installa il modulo 163179-02 all’interno di sistemi che utilizzano barriere a sicurezza intrinseca interne, assicurarsi che la temperatura ambiente non scenda al di sotto di 0 °C. Mantenere liberi i percorsi verticali sopra e sotto il telaio del rack 3500, per consentire un flusso d’aria senza ostacoli attraverso il pannello frontale della scheda. Verificare che gli slot adiacenti rispettino le regole standard di carico dell’alimentazione, in modo da mantenere la dissipazione del calore ben al di sotto del limite massimo e prevenire l’invecchiamento accelerato dei componenti.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInserimento nel telaio delle schede e coppia di serraggio del fissaggio meccanico:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePrima di inserire la scheda principale nello slot attivo, controllare visivamente le file di connettori del backplane per individuare contaminazioni o pin piegati. Guidare uniformemente la scheda lungo le guide superiori e inferiori del telaio finché i pin posteriori non si innestano saldamente nella presa del backplane. Serrare manualmente i dispositivi di fissaggio superiori e inferiori per garantire una solida messa a terra strutturale e serrare tutti i collegamenti delle morsettiere di campo secondo le schede tecniche del produttore, per prevenire variazioni del segnale indotte dalle vibrazioni.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666515226987,"sku":"3500\/61 163179-02","price":3000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-61-163179-02-temperature-monitor-xhteguywf4j_0b27118e-8724-42a3-9c4b-2bfdc2837e3f.jpg?v=1765440073","url":"https:\/\/www.plcprotech.com\/it\/products\/bently-nevada-163179-02-3500-61-temperature-monitor","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}